HomeMy WebLinkAbout2353 LA COSTA AVE; ; CB122769; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
04-03-2013 Patio/Deck Permit Permit No: CB122769
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
2353 LA COSTA BL CBAD
PATIO Status:
Parcel No: 2146312000 Lot#: 0 Applied:
Valuation: $6,228.00 Construction Type: NEW Entered By:
Reference #:
Project Title:
Applicant:
JERRY TABATA
TABATA RES-BUILD 400 SF FREE
STANDING DECK CITY SPECS
6764 LONICERA ST
CARSLBAD CA 92011
760-801-7342
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Strong Motion Fee
Green Bldg Standards (SB1473) Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Additional Fees
TOTAL PERMIT FEES
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Owner:
TABATA FAMILY TRUST 01-14-83
PO BOX 943
CARLSBAD CA 92018
ISSUED
12/28/2012
LSM
04/03/2013
04/03/2013
$97.47
$0.00
$68.23
$0.00
$1.00
$1.00
$0.00
$0.00
$0.00
$0.00
$167.70
Total Fees: $167.70 Total Payments To Date: $167.70 Balance Due:
cQ e __#FINAL APPROVAL
Inspector:~ ~ Date: 7'.-:f-/J. Clearance:
$0.00
NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this pemiit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f i n fwhi ha r vi 1 Tl E i i r h f. i i I h rw·
THE FOLLOWING A~PROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 BUILDING □FIRE □HEALTH 0 HAZMAT/APCD
ft.:-Building Permit Application Plan Check No. ~ I ';J. ,;).:,
~ G'~ 1635 Faraday Ave., Garlsbad. CA 92008 ~ C I TY O F Ph: 760-602-2719 Fax: 760-602-8558
CARL?BAD email: buldllng@carlsbadca.gov
~ www.carlsbadca.gov 35 ~ W:'.:> 1 r ' ~LVD
Est. Value
Plan Ck. Deposit
Date I "Z., 12-SWPP
SUITE#/SPACE#/UNIT# -~3/ -2,D -c'.D
PHASE# # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP
DESCRIPTION OF WORK: Include Square Feet of Aff'ected Atea(s)
&-0' Xl a-o' ~ -sl-AAJ'i d;r.J.._
EXISTING USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR COND1TIONING FIRE SPRINKLERS
YES □#_ YES □ N□p' YES □ NO)"'
APPLICANT NAME (Primary Contact) APPLICANT NAME (Secondary Contact)
ADDRESS ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
l~
CONTRACTOR BUS. NAME
ADDRESS
CITY ~II CITY STATE ZIP
PHONE FAX
AL
ARCH/DESIGNER NAME & ADDRESS STATE LIC. # STATE UC.# CLASS CITY BUS. LIC.#
(Sec. 7031.5 Business and Professions Code: Any City or Coun_ty which requires a permit to.construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Section 7000 of Division 3 of the
Business and Professions Code) or that he is exemP.t therefrom. and the basis for the alleged exemption. Any violation of Section 1031.5 by any applicant for a permit subJects the applicant to a civil penalty of not more than five hundred dollars ($500)).
WORICIIRS' C:OMl'liNSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the fol/owing declarations:
□ I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which !his pennit is issued.
□ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for Iha perfonnance of the work for which this permit is issliE!d. My workers' compensation Insurance carrier and policy
number are: Insurance Co. ______________________ Policy No. ______________ Expiration Date _________ _
This section need not be completed if the permit Is for one hundred dollars ($100) or less. D Certificate ri Exemption: I certify that in the performance of the work for which this pennit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and clvll fines up to one hundred thousand dollars (&100,000), In
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, Interest and attorney's fees.
_15 CONTRACTOR SIGNATURE □AGENT DATE
OWNl!R-BUILDliR OliCl.ARATION
I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completjon, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale).
□ I, as owner of the property, am exclusively contractjng with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
□ I am exempt under Section Business and Professions Code for this reason:
1. 1 personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. 1 (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (fiml) to provide the proposed construction (include name address/ phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (ir.clude name I address I phone /type of work): _,
,.65 PROPERTY OWNER SIGNATURE □AGENT DATE
COMPLETE THIS SECl'ION FOR NON•RESIDENflAL BUILDING Pl!l!MlfS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and JJ"evention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLl,.UTION CONTROL DISTRICT.
CONSTRUCl'ION LENDING AGENCY
I hereby affirm that there Is a construction lending agency for the performance of the work this perrrut is issued (Sec 3097 (1) Civil Code).
Lender's Name Lender's Address
APPLICANT CERTll'ICAl'ION
I certify !hat I have read the appllcatlon and state that the above lnfomlatlon Is oonectancl that the infonnation on lhe plans is accura1e. I agree to comply with all City ordinances and State laws relating to building oonstruction.
I hereby aulhooze re~tative of the City of Qrlsbad to enterupoo the above mentioned ~perty br inspection pul'J'.X)SeS. I ALSO AGREE TO SAVE, INDEMNIFY .AND KEEP HARMlESS THE CrTY OF CARLSBAD
AGAJNST ALL LIABILfTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCR\JEAGAJNST S'JD CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: AA OSHA pemilt is requred klf excavations over 5'0' deep and demdltkm or oonstruction of struch.Jres over 3 stories in height.
EXPIRATION: Every permit issued by the BJik:ling Cffcial under the provisklns of this Code shall expire by limitation and oooome null and void~ the buik:ling oroork authorized by such permit is not CXl!Tlmenced 'Mlhin
180 days from the date of such pemilt or if e buikling oroork authorized bys It· suspended or abandoned at anytime after the oork IS oommenced for a perkxl of 180 days (Sectkln 106.4.4 Unibmi BJikling Code) .
..f!S' APPLICANT'S SIGNATURE DATE
• STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email www.building@carlsbadca.gov or Mail the completed form to City of Cartsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CONTACT NAME
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
DELIVERY OPTIONS
□ PICK UP: □ CONTACT (Listed above) □ OCCUPANT (Listed above)
□ CONTRACTOR (On pg. 1)
□ MAIL TO: □ CONTACT (Listed abOYe) □ OCCUPANT (Listed above)
□ CONTRACTOR (On Pg. 1)
□MAIL/FAX TO OTHER: _______________ _
,it! APPLICANT'S SIGNATURE
CO#: (Office Use only)
OCCUPANT NAME
BUILDING ADDRESS
CITY STATE
Carlsbad CA
OCCUPANT'S BUS. LIC. No.
D ASSOCIATED CB#-------------
□ NO CHANGE IN USE/ NO CONSTRUCTION
o CHANGE OF USE/ NO CONSTRUCTION
DATE
ZIP
Inspection List
Permit#: CB122769 Type: PATIO
Date Inspection Item
04/05/2013 11 Ftg/Foundation/Piers
04/05/2013 11 Ftg/Foundation/Piers
04/05/2013 19 Final Structural
Monday, April 08, 2013
Inspector Act
RI
PB WC
PB AP
TABATA RES-BUILD 400 SF FREE
STANDING DECK CITY SPECS
Comments
Page 1 of 1
«~~> ~ CITY OF
CARLSBAD
PLAN CHECK
REVIEW
TRAN SM ITT AL
DATE:01/03/13 PROJECT NAME: TABATA RESIDENCE
PLAN CHECK NO: 1 SET#: 1 ADDRESS: 6764 LONICERA ST
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
PROJECT ID: CB 12-2769
APN:
his plan check review is complete and has been APPROVED by the ENGINEERING
Division. / er:_ I?,,, (! J
By: L 7
A Final Inspection by the Division is required Yes ✓ No
~ plan check review is NOT COMPLETE. Items missing or incorrect are listed on
/ the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: JERRYTABATA@YAHOO.COM
You may a/so have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
Chris Sexton
760-602-4624
Chris.Sexton@carlsbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
Remarks:
1;~9•~J,E;~ING
i 760-QQ2-2750 ..• :; \/is,;\',, : ,' \{-,~-;
✓ Kathleen Lawrence
760-602-2741
Kathleen.Lawrence@carlsbadca.gov
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
Greg Ryan
760-602-4663
Gregory.Ryan@carlsbadca.gov
Cindy Wong
760-602-4662
Cynthia.Wong@carlsbadca.gov
Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
1
SCALE
ITE MARKED
SHOW HOW
LOT DRA S
SHOW
CORRECT
S/APN
E-36
Set# •
Any outstanding issues will be marked with X . Make the necessary corrections for
compliance with applicable codes and standards. Submit corrected plans and/or
specifications to the Building division f'or re-submittal to the .Engineering division.
llems that conf'orm to pennit requirements are marked with ✓
1. SITE PLAN
Provide a fully dimensioned site plan drawn to scale.
X
X
X
X
Show:
· North arrow
Existing & proposed structures
Existing street improvements
Property lines (show all dimensions)
Easements
Right-of-way width & adjacent streets
Driveway widths
Existing or proposed sewer lateral
Existing or proposed water service
: Submit on signed approved plans:
DWG No.
Show on site plan:
X Drainage patterns
Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining
street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale
5' away from building".
Existing & proposed slopes and topography
Size, location, alignment of existing or proposed sewer and water service(s) that serves the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception.
Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
X
X
X
Site address
Assessor's parcel number
Legal description/lot number
For commercial/industrial buildings and tenant improvement projects, include: total building
square footage with the square footage for each different use, existing sewer permits
showing square footage of different uses (manufacturing, warehouse. office. etc.) previously
approved.
Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
Lot/Map No.:
Subdivision/Tract:
Reference No(s):
Page 2 of 6 REV 6/01/12
1
COMP TE
MWATER
E-36
Set# 1
7. STORM WATER
Construction Compliance
: ~ct Threat Assessment Form complete.
~Enclosed Project Threat Assessment Form incomplete.
Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form
and return (SW 12-)
Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
ent SUSMP Com liance
term Water Standards Questionnaire complete.
Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign
the questionnaire and resubmit with next submittal.
Project is subject to Standard Storm Water Requirements. See city Standard Urban
Storm Water Management Plan (SUSMP) for reference.
http:llwww.carlsbadca.govlbusinesslbuilding/Documents/EngStandsw-stds-vol4-ch2.pdf
Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
Rainwater harvesting (rain barrels or cistern)
Vegetated Roof
. Bio-retentions cell/rain garden
Pervious pavemenUpavers
Flow-through planter/vegetated or rock drip line
Vegetated swales or rock infiltration swales
Downspouts disconnect and discharge over landscape
Other:
Page5of6 REV 6/01/12
/4'~ "'-' ~,-.
~ CITY OF
PLANNI~ I ION
BUILDING PLAN CHECK
APPROVAL
CARLSBAD P-28
DATE: 4/3/13 PROJECT NAME: DECK PROJECT ID:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.Rov
PLAN CHECK NO: CB122769 SET#: ADDRESS: 2353 LA COSTA BLVD
APN:
~ This plan check review is complete and has been APPROVED by the PLANNING
Division.
By: GINA RUIZ
A Final Inspection by the PLANNING Division is required □ Yes [2J No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check APPROVAL has been sent to: JERRYTABATA@YAHOO.COM
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
760-602-4610 760-602-2750 760-602-4665
□ Chris Sexton □ Kathleen Lawrence □ Greg Ryan
76().602-4624 760-602-27 41 760-602-4663
Qhri!,.Sext2n'!!'c~rl!i~~dc~.gov Kathle~n.Lawrenc!;t~~grls!2i;!QCi;!,gQv ~ regoi:y. Ryg n~~!;! rlsbaQca. gQv
~ Gina Ruiz □ Linda Ontiveros □ Cindy Wong
760-602-4675 760-602-2773 760-602-4662
Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov C¥nthia.Wong@carlsbadca.gov
□ □ □ Dominic Fieri
760-602-4664
Dominic.Fleri@carlsbadca.gov
Remarks:
REVIEW#:
1 2 3
~□□
~□□
~□□
~□□
~□□
~□□
P-28
Plan Check No. CB122769 Address 2353 LA COSTA BLVD Date 4/3/13 Review# ,1.
Planner GINA RUIZ Phone /760) 602-4675
Type of Project & Use: DECK Net Project Density: DU/AC
Zoning: R-1 General Plan: RLM Facilities Management Zone: 20
CFD (in/out) #_1_Date of participation:05/07/1991 Remaining net dev acres: __
(For non-residential development: Type of land use created by this permit: __ )
Legend: ~ Item Complete
Environmental Review Required:
DATE OF COMPLETION:
D Item Incomplete -Needs your action
YES □ NO ~ TYPE
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO.
OTHER RELATED CASES:
YES □ NO ~ TYPE __
DATE
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES i2sJ. NO 0
CA Coastal Commission Authority? YES D NO i2sJ.
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive,
Suite 103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES □ NO ~
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of
Habitat Type impacted/taken, UPDATE!)
lnclusionary Housing Fee required: YES D NO ~
(Effective date of lnclusionary Housing Ordinance-May 21, 1993.)
Data Entry Completed? YES □ NO □
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct
Housing Y/N, Enter Fee, UPDATE!)
Housing Tracking Form (form P-20) completed: YES □ NO □ N/A~
Page 2 of 3 07/11
Site Plan:
□~□
~□□
~□□
□~□
□~□
□~□
□~□
~□□
□~□
Pre•,iae a fully aimeRsioRal site plaR arawR to soale. Stlow: ~lorttl arrew, preperl)· liRes,
easemeRls, eiEistiR9 aRa proposea structures, streets, e>EistiR9 street improvemeRls, ri9RI of
way wiattl, aimeRsieRal setllaoks aRd e>EisliR§ topograptlioal liRes (iRoluaiR9 all siae aRa rear
yara slepes). Previae legal aesoriplieR ef preperty aRa assesser's parsel Rumller. SEE
BUllDl~IG PERMIT SUBMITT/\l REQUIREME~ITS F'OR RESIDE~ITl/\l DECK
SUBMITT/\lS ATTACI-IED.
City Council Policy 44 -Neighborhood Architectural Design Guidelines
1 . Applicability: YES O NO ~
2. Project complies: YES D NOD
Zoning:
1. Selllasks: ~IEED MORE INF'ORM/\TIO~l TO DETERMINE IF' DECK IS PERMITTABlE
SEE BElQlJ'J
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required __ Shown
Required __ Shown
Required __ Shown
Required __ Shown __
Required __ Shown __
2. Accessory structure setbacks: ~IEED MORE l~IF'ORMATION TO DETERMl~IE IF' DECK
IS PERMITTABlE SEE BELOW
Front:
Interior Side:
Street Side:
Rear:
Structure separation:
3. Lot Coverage:
4. Height:
Required 20' Shown 120'
Required 10' Shown 35'
Required NIA Shown N/A
Required 20' Shown fil.'.
Required 10' Shown 40'
Required 40% MAX Shown 6%
Required 10' HIGH MAX Shown 4.5'
5. Parking: Spaces Required __ Shown __
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required __ Shown __
11.EIElitional Comments #1. THE IMFORP1'\TIO~J PRQIIID!iD OM Tl=le ~I IILDIMG PERP1IT OPPLICOTIOM FOR 67§4
bOMICeRI\ ST IS FOR O \IOC/\MT LOT. O 01!!.T/\Cl,,IED gecK IS MO:r PeRMITTED QM/\ \IOCOMT LOT O~JLY AS OM
ACQeSSGRY STRPCT!IR!i TO A SIMQLE FOP41b¥ RESIOliMCli. Pbe:ASE Rli!\1I~1 Tl=IE Al'+PCl=lED ASSESSORS
PARG[b PAGES NII, IDEMTIFY IG<HIGH PARGEb MUMBeR THE DECK IS BEl~IG PRQPQSED mL IF THE DECK IS
BElml PRQPQSrn ml 214 1!39 29 QQ, TWT bQT IS \l,OC,~IT •~m nle DECK IS MQT f2ERf4ITTED. II' THE DECK
IS BEl~JG f2R[lf2QSED m1 214 631 2Q 99 rnE FQbbQIG<IMG l~IFQRM,•.:nm1 ~IEEDS TQ BE ADDED<RE'/ISED m1
THE PbNIS· 1\ CHAMGE ~DDRESS QM mi; 8I llbDl~IG PERMIT Of2f2blC•TIm1 FQRM TQ REPD 231!3 bP GQSTA
Bb\lD 2\ ADD ,0 SITe f260M AT A SCAbE 3\ ADD THE E~ITIRE bQT mlCbUQIMG Obb PRQPERTY WIES STREIST
RIGHT QF WP.¥, cmlTQUR blMES THE .:~ITIRI; 1;xIsm1G HQUSE\ 4\ ~DD PSSESSQR P•RGEb ~I UMBER 214
631 29 99 MID ADDRESS 6\ ADD n!E HEIGHT QF n!E STRUCTURE •S o FbPT RQQF DETACHED •CCESSQRY
STRUCTI IRE C/\M BE A M,A;t'.JMUP1 l:iEIQHT OF 10 FEET f+l=II; 10 FEET Does MGT l~IGbUbl~ TM!; GUARQ Re\lbSj
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER GINA RUIZ DATE 4/3/13
P-28 Page 3 of 3 07/11