HomeMy WebLinkAbout2355 GEODE LN; ; CB102389; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 03-19-2012 Residential Permit Permit No: CB102389 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: 2355 GEODE LN CBAD RESDNTL Sub Type: SFD Lot#: 44 Status: ISSUED Applied: 11/01/2010 Entered By: RMA Parcel No: Valuation: 2132721700 $383,745.00 Occupancy Group: # Dwelling Units: Bedrooms: 1 3 Constuction Type: VN Reference#: CT040015 Structure Type: SFD Bathrooms: 3.5 Plan Approved: 03/19/2012 Issued: 03/19/2012 Inspect Area: PD Orig PC #: PC090040 MIRASOL' PHASE 5/BUILDOUT Plan Check#: PC100050 Project Title: PLAN 4, 3217 SF, 602 SF GAR, 211 SF PORCH Applicant: WILLIAM LYON HOMES 4490 VON KARMAN AV 92660 949 833-3600 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $1,679.69 $0.00 $1,091.80 ($500.00) ($87.34) $38.37 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3,549.00 FS1 $0.00 $0.00 $12.00 ?? Owner: WILLIAM LYON HOMES INC 4490 VON KARMAN AVE NEWPORT BEACH CA 92660 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF(3105540) PFF(4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES Total Fees: $25,652.98 Total Payments to Date: $25,652.98 Balance Due: Inspector: FINAL APPROVAL Date: f · 2 · f 't---Clearance: FS1 $0.00 $403.00 $4,492.00 $3,122.05 $6,984.16 $0.00 $0.00 $0.00 $2,340.00 $0.00 $0.00 $210.00 $66.25 $88.00 $0.00 $0.00 $0.00 $0.00 $1,969.00 $195.00 ?? $25,652.98 $0,00 NOTICE: Please take NOTICE that approval of your project Includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these tees/exactions. !I you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Ca1!sbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul tlleir imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees ln connection with this project NOA DOES IT APPLY to any f fhih h nivnNT 'Ir whih hmii h I City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 03-19-2012 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW100541 Job Address: Permit Type: 2355 GEODE LN CBAD SWPPP Status: Parcel No: 2132721700 Lot#: 44 Applied: Reference #: CB#: Project Title: Applicant: CT040015 CB102389 MIRASOL -PHASE 5/ BUILDOUT WILLIAM LYON HOMES INC 4490 VON KARMAN AVE NEWPORT BEACH CA 92660 Emergency Contact: WILLIAM LYON HOMES ATTN: DAN 858 583-1681 SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES Entered By: Issued: Inspect Area: Tier: Priority: Owner: WILLIAM LYON HOMES INC 4490 VON KARMAN AVE NEWPORT BEACH CA 92660 ISSUED 11/01/2010 RMA 03/19/2012 PD 1 M $0.00 $208.00 $0.00 $208.00 Total Fees: $208.00 Total Payments To Date: $208.00 Balance Due: FINAL A·· ,· --·, " -· : ·--v,~ .. • I· • , ; ~\ '!tft,-d' DATE <j • ~ ..:_ 13:e4 __ SIGHATUR1: _ _;;:{j ;;['"· ---~---- $0.00 Inspection List Permit#: CB102389 Type: RESDNTL SFD MIRASOL-PHASE 5/BUILDOUT PLAN 4, 3217 SF, 602 SF GAR, 211 SF PO Date Inspection Item Inspector Act Comments 08/02/2012 89 Final Combo RI 08/02/2012 89 Final Combo PD AP 07/05/2012 39 Final Electrical PD AP 06/05/2012 82 Drywall/Ext Lath/Gas Test PD AP 06/04/2012 18 Exterior Lath/Drywall PD AP 05/25/2012 84 Rough Combo PD AP 05/15/2012 13 Shear Panels/HD's PD AP 05/09/2012 15 Roof/Reroof PD AP 04/09/2012 11 Ftg/Foundation/Piers PD AP 03/30/2012 21 Underground/Under Floor PD AP 03/30/2012 22 Sewer/Water Service PD AP Monday,August06,2012 Page 1 of 1 Southwest Inspection an d Testing, Inc. 441 Commercial Way, La Habra, Ca 90631 (562) 941 -2990 • (714) 526-8441 • Fax (562) 946-0026 Date REGISTERED INSPECTOR'S DAILY REPORT SWIT Job No I \00/L '-l--I~ TYPE OF CJ Reinforced Concrete D INSPECTION ~ Post Tensioned Concrete D Structural Steel Assembly Fire Proofing REQUIRED O Reinforced Masonry 0 Asphalt Job Name IV\ · ("> \ I \ _< Type of Structure 0J ( GJ Architect Engineer Subcontractor TESTS PERFORMED • • • Quality Control Wood Framing cJ TYPE OF SAMPLE SLUMP QUANTITY IN SET ADDITIONAL REMARKS ON SAMPLE INSPECTION SUMMARY -LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS. ETC INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER. TYPE & !DENT NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS ELD MADE HT BOLTS TORQUED) CHECKED, ETC. L CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE • PAGE _J_ OF _1_ ?'KNOWLEDGE TIME IN TIME OUT SAMPLES 7 - SIGN~llJRE,., R I TEt:D INSPECTOR ~~ )\-9-eS \t Cc~ 54..."'-:6:J }X}b1=,.c__c . SPECIAL TY NO. AGENCY White -Office Copy • Canary-Accounting Copy • Pink -lnsp . tor's Copy • Goldenrod -Jobs,te Copy PLANNING ENGINffRlNC 'iURVFY/N(, JRVINE 1.0SANGHES RIVER5111F SAN DIEGO ARIZONA n,wr I (AMMAR 11:X Wlll.lMAN Al.lSA Vl,'\LPANI)( J DAN SMITH RAY MARTIN Cl IUCK LAlU! 1)707 W,1ple~ Strl'PI S,rn DiPW>, CA 92121 !Wi8l 'i5fl-4500 PH tll'iRl '.'i!J. 141,! I" X l\'WW,l lun~.lk('r::i!J,('lllll lnlo~•lf IUl\',,-lkPrSI ),rom HUNSAKER &ASSOCIATES <, A N D 1 F r; 0, I N 1 April 4, 2012 City of Carlsbad Engineering Department 1635 Faraday Avenue Carlsbad, CA 92008 Subject: Civil Engineer's Project: Certification of Building Form Title: Dwg: Tract: Lots: La Costa Greens Neighborhood 1.07 427-7A CT 04-16/04-14A 38 through 42 Please be advised the building foundation forms are in conformance with the precise grading plans as to horizontal and vertical location within one tenth of a foot Gary C. Kr P.L.S. 8770 Hunsaker & Associates San Diego, Inc. Wil 59\ 34 4,4i201/UJ9,'-lw1 GEOCON O = INCORPORATED GEOTECHNICAL •ENVIRONMENTAL • MATERIALS~ 6960 FLANDERS DRIVE • SAN DIEGO, CALIFORNIA 92121-297 4 • TEL (858) 558-6900 • FAX (858) 558-6159 ~ FOUNDATION OBSERVATION REPORT PROJECT NAME : __ E~~_,F __ G,_.-::_r_~_~_.1 __ 1_c_r _________ PROJECT NO. LOCATION : L..;,T;:, '-I~, -L/ l ..J 2 J -'"I 3 . ( AGENCY PROJECT NO : APPROVAL/ PERMIT NOS :!.1· 0/JL31 n DATE ,;/r-/2 ' ;L. .J) 11•-/ ,_p,, """1 ~;r:; ~ '--' 39 ? 1 ?I '/ lt / Z a I 7-- FOUNDATION TYPE: 'I<. I .J,7 7 4a: °&" v1o • ADDITIONAL OBSERVATION REQUIRED D CONVENTIONAL 't ., 3 7 f l 'I-I : :?.~ ~ ~TANTIAL CONFORMANCE D POST-TENSIONED i:i .:J7 2 4-L·. 3; • PURPOSE OF OBSERVATION 't'i I -.>10 H~. . '/ 17 I B Check soil conditions exposed are sim ilar to those expected D Check footing excavations extend to mini mum depth recommended in soil report D Check footings have been extended to an appropriate bearing strata D Other , • _:S ,y ·-'-I o/ t • v ;; I, . .. .. ) , ,. . v-< ,.,_ h-, 1 ----:, • APPLICABLE SOIL REPORT : TITLE: _.::..t-L=-'-J_D_4_r_r_...,,w_....,'-·,_. -'-"'-'....ce_,=--'-_,_l _ ____.:_l_'-__ .., __ v. __ ~ _ ____,"=-· _,.,.. __ L.,... __ L.o __ r_,.._,_~ -,-;,. , C:.-z. r E-, ...i • I u C DATE : 1JI, _.,_ Z.o/,o • SOIL REPORT RECOMMENDATIONS BASED ON : E:I Expansion Condition D Very Low (0-20) (3' Low (21-50) B' Medium (51-90) D High (91-130) D Very High (>130) D Fill Geometry ._.., D Other:-------------------------------------- • MINIMUM FOUNDATION RECOMMENDATIONS : .iL ~ Footi ng Depth : D 12 Inches D 18 Inches D 24 Inches OTHER fl-::. f ' f. J :.:-/t '!. 2 1 Footing Reinforcement : D No.4 T&B D 2-No.4 T&B D 2-No.5 T&B B'Post-Tensioned OTHER : ______ _ Interior Slab Rei nforcement: D 6x6-10/10 D 6x6-6/6 D No.3@241nches D No.3@181nches B-Post-Tensioned • FOUNDATION CATEGORY: DNA ________________ _ ~ DI ___________________ _ L/1 1 3"1 1 jD Erm • OBSERVATIONS : Ei'substa ntial conformance with Soil Report. D Substantial conformance with Foundation Plans. Identify : ___________________ _ D Other • COMMENTS:---------------------------------- fu-sTE : FOOTING EXCAVATIONS SHOULD BE CLEANED OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THE SOIL MOISTURE CONTENT SHOULD BE MAINTAINED. FOR 2011 FIELD COPIES TO GEOCON REPRESENTATIVE INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope -Insulation; Roofine:; Fenestration (Page 1 of3) Site Address: 2355 GEODE LANE LOT 441 Enforcement Agency: I PermCE3102389 CARLSBAD. CA 92009 City of Carlsbad If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures with check boxes require to be checked to ensure the mandatory measures have been met. Description of Insulation 1. RAISED FLOOR Material: NA Brand Name: NA --------------Thickness (inches):___________ Thermal Resistance (R-Value): r:!f' § I 50( d): Minimum R-I 3 insulation in raised wood-frame floor or equivalent U-factor. -------- 2. SLAB FLOOR/PERIMETER Material: NA Brand Name: NA --------------Thickness (inches): ___________ _ The rm al Resistance (R-Value): ______ _ Perimeter Insulation Depth (inches): ~~----• § 150(1): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. 3. EXTERIOR WALL a. Insulation Type (e.x. Batt, Loose Fill, Spray Foam) FIBERGLASS BATTS b .. Insulation Type (e.x. Batt, Loose Fill, Spray Foam) FIBERGLASS BATTS Brand: JOHNS MANVILLE a. Thermal Resistance (R-Value): R-13 ------- b. Thermal Resistance (R-Value): R-19 ------- Spray/Loose fill) Installed Actual Thickness Spray/Loose fill) (inches): NA Contractor's min installed weight/ft' __ lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value) • § 150(c): Minimum R-13 insulation in wood-frame wall or equivalent U-factor. Exterior Foam Sheathing (rigid Insulation) Material: NA Brand Name: NA Thickness (inches): _________ _ Thermal Resistance (R-Value): ------- 4. FOUNDATION WALL Material: NA Brand Name: NA Thickness (inches): -----------Thermal Resistance (R-Value): ______ _ 5. CEILING Batt or Blanket Type: FIBERGLASS BATTS Brand Name: JOHNS MANVILLE Loose Fill Type: FIBERGLASS BLOWN Thermal Resistance (R-Value): R-30 -Se---'~----S pray Foam Type: NA Brand Name: JOHNS MANVILLE Installed Actual Thickness (inches): 13.20" Contractor's min installed weight/ft' .972 lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value): l!f § I 50(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. 6. ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER Material: NA Brand Name: NA --------------Mater i a I:_______________ Brand Name: _____________ _ Thickness (inches): ---,--~c-------,--~~~ Thermal Resistance (R-Value): ______ _ • § l 18(a): Insulation installed meets Standards for Insulating Material. D § I 50(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. 2008 Residential Compliance Forms August 2009 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope -Insulation; Roofin2; Fenestration (Page 2 of3) Site Address: 2355 GEODE LANE LOT 441 Enforcement Agency: I PermCB102389 CARLSBAD. CA 92009 r.jtv nf C:,rli;b"n Description of Roofin2 Products CRRC Product ID Manufacturer Product Roof Roof Product Initial Solar Aged Solar Thermal Number1 Information Brand/Model Tv= Area Slooe Weiaht 2 Reflectance Retlectance4 Emittance •' •' •' I. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at ww.coolroofs.orglproductslsearch.php 2. The weight in lbs per square feet of the roofing product being installed. 3. Check box if the Aged Reflectance is a calculated value using the equation below,footnote 4. 4. If the aged reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the initial reflectance value from the directorv and use the equation (0.2+0. lfn,ni ;01-0.2) to obtain a calculated aJZed value. ✓ DCHECK APPLICABLE BOX BELOW IF EXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENT, D The roof area covered by building integrated photovoltaic panels and building integrated solar thennal panels are exempt from the above Cool Roof criteria. D Roof constructions that have thennal mass over the roof membrane with a weight of at least 25 lb/ft'"' is exempted from the above Cool Roof criteria. To apply Liquid Field Applied Coatings, the coating must be applied with a minimum dry mil thickness of 20 mils across the entire roof surface and meet minimum nerformance reouirements listed in §I I 8(03 and Table I I 8-C. Select the annlicable coatin!l 0 Aluminum-Pi2mented Asohalt Roof Coatin2 I O Cement-Based Roof Coatimz I D Other ✓ 0 CRRC-1 Label Attached to CF-6R (Note i{no CRRC-1 label is available, this compliance method cannot be used and another method is required to meet comvliance). FENESTRATION/GLAZING Product # Total Quantity Add. Exterior Comments/ Manufacturer/Brand Name U-Product of NFRC of Like Product Area Shading Dev. Location/ Special Item (GROUP LIKE RODUCTS\ factor1 SHGC1 Panes Certifiei· 2 (Optionafl ft' or Overhang Features 1 2 3 4 5 6 7 8 [. Use values.from afenestralion product's NFRC Certified Label. For fenestration products without an NFRC label, use the default values from Section I 16, Table I 16-A and I 16-B of the 2008 Energy Efficiency Slandards. 2. NFRC Label Certificates shall not be removed until the buildinf! ins~ctor has verified the efflciencv. Enter Yes or No. 0 §I 16(a)l: Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. D §I 16(a)2 and 3: Actual fenestration products installed are equivalent to or have a lower U-factor and/or a lower SHGC than that specified on the Certificate of Compliance (Form CF-IR). D § I 16(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of§ I 0-111 (a) D § 117: Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed. 2008 Residential Compliance Forms August 2009 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelooe -Insulation; Roofine:; Fenestration (Page 3 of 3) Site Address: 2355 GEODE LANE LOT 441 Enforcement Agency: I Pe~~~02;89 CARLSBAD CA 92009 Citv of Carlsbad DECLARATION STATEMENT • I certify under penalty of perjury, under the laws of the State of California, the infonnation provided on this form is true and correct. • I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction (responsible person). • I certify that the installed features. materials, components, or manufactured devices identified on this certificate (the installation) confonns to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. • I reviewed a copy of the Certificate of Compliance (CF-1 R) fonn approved by the enforcement agency that identifies the specific requirements for the installation. I certify that the requirements detailed on the CF-1 R that apply to the installation have been met. • I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) QUALITY INTERIORS, INC. Responsible Person's Name: Responsible Person's Signature: Jennifer Dinsmore J~V~e CSLB License: I Date Signed: Position With Company (Title): 802519 8/2/2012 Admin. 2008 Residential Compliance Farms August 2009