Loading...
HomeMy WebLinkAbout2356 MERWIN DR; ; CB991149; PermitCity of Carlsbad Residential Permit Permit No:CB991149 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: 03/31/1999 # Dwelling Units: Bedrooms: Project Title: Applicant: SHEA HOMES STE 200 Building Inspection Request Line (760) 602-2725 2356 MERWIN DR CBAD RESDNTL Sub Type: SFD 2081622400 Lot#: 130 $260,347.00 Construction Type: VN 6 Reference #: CT96-07 1 Structure Type: SFD 5 Bathrooms: 2.75 CANTEBURY-KELLY RANCH VILLE PLN 4 PHS 1, 3038 SF, 457 SF GAR,60 SF DECK Owner: SHEA HOMES ·stt200 Status: Applied: Entered By: Issued: Inspect Area: Orig PC#: Plan Check#: 10721 TREENA STREET SAN DIEGO CA 92131 92131 619-549-3156 10721 TRl:ENA Sf SAll!OIEGO CA 91.1131' • · 619-549-3156 ISSUED 02/26/1999 OT Plan Approved: 10/18/1999 PC990026 PC990027 Total Fees: $17,466.02 Total Payments To Ol!te: $17,128.38 Balance Due: $337 .65 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD#2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee $1,184.58 $0.00 $769.98 . $0.00 ($61.60) $26.03 $1,575.00 $0.00 $0.00. $8.00 $0,00 :SO.DO • $0.00 $0.00 $0.00 $0.00 $2,400.00 D5/8 $0.00 $0.00 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoll Fee PFF PFF (CFO Fund) License Tax , License. Tax (CfO Fiund) · "trafl!li Impact Fee .. 1aifflc tmpac:) tdEb Fund) ; .LFl\.1~ :nari11p111rfalion Fee • Sidewall( 'Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnLieu Fee Master Drainage Fee: Sewer Fee: TOTAL PERMIT FEES $0.00 $0.00 $0.00 $3,664.71 $4,738.32 $0.00 $0.00 $0.00 $550.00 $0.00 $0.00 $0.00 $147.00 $60.00 $63.00 $0.00 $0.00 $0.00 $2,349.00 $17,466.02 FINAL APPROVAL Date: ¥.-j?-0(/ Clearance: g., · Do NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 City of Carlsbad Bldg Inspection Request For: 8/7/2000 Permit# CB991149 Inspector Assignment: PS --- Tille: CANTEBURY-KELLY RANCH VILLE Description: PLN 4 PHS 1, 3038 SF, 457 SF GAR,60 SF DECK Type: RESDNTL Sub Type: SFD Job Address: 2356 MERWIN DR Suite: Lot 130 Location: APPLICANT SHEA HOMES Owner: SHEA HOMES LTD PARTNERSHIP Remarks: Total Time: Phone: 6198439517 Inspector:~ Requested By: DAVE Entered By: CHRISTINE CD Description Act Comments 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs lnsgection Histo[ll Date Description Act lnsp Comments 8/4/2000 89 Final Combo NR PS 8/3/2000 89 Final Combo co PS 7/20/2000 39 Final Electrical co PS OK TO RELEASE ELEC 6/6/2000 82 Drywall/Ext Lath/Gas Test AP PS 5/30/2000 16 lnsulation AP PS 5/25/2000 84 Rough Combo AP PS 5/23/2000 14 Frame/Steel/Bolting/Welding CA PS 5/22/2000 14 Frame/Steel/Bolting/Welding co PS 5/9/2000 13 Shear Panels/HD's AP PS 4/20/2000 15 Roof/Reroof AP PS 3/14/2000 11 Ftg/Foundation/Piers AP PS 3/14/2000 12 Steel/Bond Beam AP PS 2/7/2000 21 Underground/Under Floor AP PS 2/7/2000 22 Sewer/Water Service AP PS Altn. C.1Nbr[ ·,i 111,,.._ 4'\oMk _:r;,,. INSPECTION RECORD INSPECTION RECOIO CAIO WITH APPROVED PlANS MUST BE ICePT ON THE JOB CAll PRIOR TO 2:00 P.M. FOR NIXT WOIOO>AY INSPfCTION IUIU)ING INSPECTION: (760) 438-3101 )0811DllllfS5' _______________________ LOTNO.ISUl'TE! _____ _ .,.,,...._, __ Jffl?Tl':YiQ' IJ'l'IIOVB> TO CUVta .,,.. .. _ ---IIUltDIHC , -fOU"Qf,TIOH -Viz REINFORCED 5TE£l 7• ....,._. . DGIIO<JT □WAU.OltANS TILTPANll.S l'OURS'IIIPS ~ fOOIINGS ,._ DFUJOII. O<HJNC - ROOF SHfA1HINC EXT.~ P""65 -~o -L·,;Z$,,,...-. ~-INS\MllON ,c;.--· .. c,c, fXIRIOltlAlH . --lk'TEIUOR lATH & DltYWAU. , ..... ·~ --■stwBI.NIOIIA:O 9PIA:O '. --flWAS'lf 0WA1B ... -.c~"V rorour OWMIE OWATEll ,,..---. H TUI, AHO SlilOWOt P~ ~,e,..,. I . ..,...,..,. □CA<N'ING ., . "" • C WAHR. HL\10. □ SiOlM WATflt -EUC1IUCAl ' ~-JI.Ufa< '~-•.Cl() .,, I / , ltOUCM BECTRJC: WAl.15 --IJ IIOOOI ELICTRlC cmJMC .".: "U• ·~~ □ lUCIIOCSl!Ma 0-a""""'"" Dl'OOl -MfOIANICAl -"-""'DER0IKJUND OUC1S & PIPINC • // a DUCT&: 11'1.tM..O ttrr. """'4C ,,. V HEAT -~COHO. SYSTEMS /J7t ✓ / ~· _..,.TINC >YmM> " -CALL fOIII: RN,U IHSPlCTI0H WHEH~U A.BOW HAIi£ BEEH Al'l'AOl,l£D 111W Stll"Mr..AWUIPILdt ----.Q9..J101 --Ul-2121 --431--11,1 ·~ ,._ ~Dept.I.II I r tll ... ,.,, ....., ...... ~u_..,_,. --CMWD ◄38--2122&1:nSl ~.,,, .~ ~J. --_, , , SU 8AOtfOR.5f"fCW..NOTE5 ~ :t'IIJll'ttn9. -~ 98115 HOt tOI OIL D.i itt~Cl ta. OOOz:t.LO!tO . .. - DAILY FIELD ENGINEERING REPORT PACIFIC SOILS ENGINEERING, INC. Client: 1 Work Order: ◊.:.>6e:;,,...., _, Clients Representative: Tract No.: Date: -1/ 1/60 Project Name: Day: / J /.,1 t -s,-/ r, 1 Project Location: Weather Conditions: 'H 1 1 Contractor: Approximate Fill Yardage: Type and Number of Rigs in Operation: Description of Project Activities: , ,,,.. ., --I I. . ✓ ... --I ...,.--I ,.,,,,"& :,"',•~1,,, .. _ A.,/1!:.J ""·-c. 1.c~ y,-·r,vr,. s J. ,,,---:, ~ .. -,,. .. 1 Site Visitors / Firm: HOURS BILLED TECHNICIAN TO PROJECT For Pacific Soils Engineering, Inc. Field Office ".=-,. c .-:r I ~ / ' '•-C°>,',".~.:::::. _;;.> Received by: Page _of_ dafldmt.sam I I . ' -. PREFERRED CONSTRUCTION INSPECTIONS, INC. 4888 RONSON COURT "G" SAN DIEGO, CA 92111 TELEPHONE (858) 576-9110 I JOB NO. rORWEEK j /J ~ / p CERTIFIED INSPECTOR'S WEEKLY REPORT ENDING COVERING WORK PERFORMED D _,REINFORCED CONCRETE D STRUCT. STEEL ASSEMBL y D SPRAY-APPLIED FIREPROOFING WHICH REQUIRED APPROV AL BY (a PRE-STRESSED CONCRETE D REINFORCED GYPSUM OoTHER THE SPECIAL INSPECTOR OF D REINFORCED MASONRY D DEEP FOUNDATION JOBA:i,ss ~ //' / (/ J , BU~~'?RMIT Nt' Bi aJ I Pl.AN FILE NUMBER OWNER OrOJECT NAME .. f //2 /1 } ARCHITECT fl~ • /J' ( -I - CONSTR. MAT'l. (TYPE. GRADE, ETC.I I DESIGN I SOURCE OF MFGR. ENGINEER / 1,,. I~/ ~ STRENGTH I '/, I f '\ ) J. L DESCRIBE MA Tt (MIX DESIGN, RE-BAR GRADE & MFGR .. WELD-ROD, ETC.) GENERAL CONTRACTOR .311/r.7 ' /. /; ,.tlb r__;.J-COHTR. ,N/q RE70v , J J I.All. RECEIVING & TE/ING CONSTR. MA rL. SAMPLES " 1-✓I INSPEC· ARRIVAL DETAILED LOCATION OF WORK INSPECTED. TEST SAMPLES TAKEN, WORK REJECTED, JOB PR08LEMS, PROGRESS. REMARKS, ETC. TION TIME. REPORT OF DATj DEPARTURE WORK IHCl.UOU ,._TION _...wolMIO,MAffllW.Jll.AUDOll _ l'f_D: _11. TYN! • 101:HT.NO'S. O,fllT s-.,a TAKEH; STRUCT. 'TIME INSPECTED CONfKTI<WI IWILOI MAOI!. H. T. IQ.Tl Ta!OUl!DI CHKICED: ETC . . . , v J--IJ J I 'l l'I it/-' /l,_v, ,J Lv,J~• br :/~u£J /ff /½~!i.£'2 -~ ~'d 1/1_1,,,.-J ;iy 1uJ//2/~L / /JI/V If '1✓'l~t7 J !J'L I I/.<,' ~ .. -p / ..v'.J f'I /?'/ -2~&, 11/✓--1t11JtAJ ~L, -/~'171 /'If Ji~ I /' /]/ ' ;jJ /~ -:Z¥1 ,-fr tJ --,,IJ 1/1'7 . ' 4 - J 'I!/~ /.t ./;Jj/,V/ JA.f J,"r?·r/PA.J .,I /iz'Jh .. I 1.,/ ~/ I 'b// / / 1 / , /-:. ~~r/?J,/5 I 1.-'W J ,' ' //// ln1 · / J//) 1)//"/ Plhtl /JI. .. / /1 1./i.J II fLJ ) .., "t> I /J j tit -~ -- - L 1.,£/f;J,,l / lllZILL L!/4''h /0/_J ~ l.,L/141 ./,/1{)1#;/ ,, U!rl I ,; I/ I t:1/ f.7/,. /.;i J ,r!t~_I Jh?/L1L./Ji1LL ./{'eL!aUJ LJ/ -'17~ 1/,1 /' I ' 1AII ~<'5 A//,~? I 11/ " I~~ a .,tt~ l:..M'ut -J;/. . -1/(j/f'~ i.J/4Al/~1£/ rJl/£ //f././Lf4Ju:t/7 .L.,,P A1JIL11/,2.L, 1P Ir~ f~ /_//I _/y~/~tl ,., -~r.a / .,.,- I J . -------- ~ ---7T' / - INSPECTOR •-OflT'Ml / ,,._ .(// '/:.. §::. SIGNATURE J ._,~/I /&;i DATE SIGNEo//!/1 //I.✓ CERTIFICATE NO. ,, 'l IIOIW:AU._,_ __ TN-tY-Y0/1''1141Wllll~'1141MNCTDIOA-. CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all of the reported work, unless otherwise noted, substantially complies with approved plan~ specifications and applicable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering opin ion or project control. ---------