HomeMy WebLinkAbout2357 MICA RD; ; CB080012; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
12-29-2010 Residential Permit Permit No: CB080012
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
12/29/2010
# Dwelling Units:
2357 MICA RD CBAD
RESDNTL
2132821500
$427,146.00
Sub Type:
Lot#:
Construction Type:
Reference #:
SFD
41
VN
CT 04006
Structure Type: SFD
Status:
Applied:
Entered By:
Issued:
Bedrooms: 4 Bathrooms: 4.5 Inspect Area:
Project Title: VIRIDIAN-LA COSTA GREENS-PH$ 8 Orig PC#:
PLAN 3: 3953 SF LIV -700 SF GAR -231 SF DECK -175SF
cov.
Plan Check#
PORCH
Applicant:
APRIL TORNILLO
C/O TAYLOR MORRISON OF CA, LLC
15 CUSHING
IRVINE 92618
949-341-1289
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
$1,698.33
$0.00
$1,103.91
$0.00
($88.31)
$42.71
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$4,878.00
D3/4
$182.00
$0.00
??
Owner:
TAYLOR MORRISON OF CA, LLC
15 CUSHING
IRVINE
CA 92618
949-341-1289
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF (3105540)
PFF(4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee ( 4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
ISSUED
12/27/2007
JMA
Plan Approved:
12/29/2010
PC060023
PC070087
$0.00
$190.00
$4,492.00
$3,122.05
$7,774.06
$0.00
$0.00
$0.00
$2,286.80
$0.00
$0.00
$174.00
$60.00
$103.00
$0.00
$0.00
$0.00
$0.00
$2,018.00
$125.00
??
$28,161.55
Total Fees: $28,161.55 Total Payments To Date: $28, 161 .55 Balance Due: $0.00
Inspector: Date: Clearance:
NOTICE: Please take that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to Water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f wih I hih f' in h ir
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
12-29-2010
Storm Water Pollution Prevention Plan (SWPPP) Permit
Permit No:SW100471
Job Address:
Permit Type:
Parcel No:
Reference #:
CB#:
Project Title:
Applicant:
2357 MICA RD CBAD
SWPPP
2132821500
CB080012
VIRIDIAN: PHS. 8
TAYLOR MORRISON OF CA, LLC
15 CUSHING
IRVINE
CA 92618
949-341-1289
Emergency Contact:
GARY BOUCK
949-246-7922
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Status:
Lot#: 41 Applied:
Entered By:
Issued:
Inspect Area:
Tier:
Priority:
Owner:
TAYLOR MORRISON OF CA, LLC
15 CUSHING
IRVINE
CA 92618
949-341-1289
ISSUED
11/23/2010
JMA
12/29/2010
1
M
$0.00
$208.00
$0.00
$208.00
Total Fees: $208.00 Total Payments To Date: $208.00 Balance Due: $0.00
Inspection List
Permit#: CB080012 Type: RESDNTL SFD
Date Inspection Item Inspector
12/05/2011 89 Final Combo PY
12/05/2011 89 Final Combo
12/01/2011 89 Final Combo
12/01/2011 89 Final Combo PY
11/30/2011 89 Final Combo
11/30/2011 89 Final Combo PY
11/07/2011 39 Final Electrical PY
09/26/2011 82 Drywall/Ext Lath/Gas Test PY
09/22/2011 17 Interior Lath/Drywall PY
09/21/2011 17 Interior Lath/Drywall PY
09/19/2011 16 Insulation PY
09/14/2011 14 Frame/Steel/Bolting/Weldin PY
09/14/2011 24 Rough/Topout PY
09/14/2011 34 Rough Electric PY
09/14/2011 44 Rough/Ducts/Dampers PY
09/08/2011 84 Rough Combo PY
08/31/2011 13 Shear Panels/HD's PY
08/17/2011 15 Roof/Reroof PD
07/11/2011 11 Fig/Foundation/Piers PY
07/05/2011 21 Underground/Under Floor PY
07/05/2011 22 Sewer/Water Service PY
Tuesday, December 06, 2011
Act
AP
RI
RI
CA
RI
NR
PA
AP
PA
NR
AP
AP
NR
AP
AP
NR
AP
AP
AP
AP
AP
VIRIDIAN-LA COSTA GREENS-PHS 8
PLAN 3: 3953 SF LIV· 700 SF GAR• 231 S
Comments
GMR
EMR
1ST LAYER LID
Page 1 of 1
City of Carlsbad Bldg Inspection Request
For: 12/05/2011
Permit# CB0B0012 Inspector Assignment: PY
Title: VIRIDIAN-LA COSTA GREENS-PHS 8
Description: PLAN 3: 3953 SF LIV -700 SF GAR • 231 SF DECK· 175SF
COV. PORCH
Sub Type: SFD
---
Type: RESDNTL Phone: 9492467922
Job Address: 2357 MICA RD
Suite: Lot: 41
Location: Inspector:
OWNER TAYLOR MORRISON OF CA, LLC
Owner: TAYLOR MORRISON OF CALIFORNIA LL C
Remarks:
-----
Total Time: Requested By: GARY
Entered By: JANEAN
CD Description Act Comments
19 Final Structural 0fh 8-
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC# PC060023
SW100468 ISSUED VIRIDIAN: PHS. 8;
SW100469 ISSUED VIRIDIAN: PHS. 8;
SW100470 ISSUED VIRIDIAN: PHS. 8;
SW100471 ISSUED VIRIDIAN: PHS. 8;
SW100472 ISSUED VIRIDIAN: PHS. 8;
SW100473 ISSUED VIRIDIAN: PHS. 8;
lnsQection Hisloct
Date Description Act lnsp Comments
12/01/2011 89 Final Combo CA PY
11/30/2011 89 Final Combo NR PY
11/07/2011 39 Final Electrical PA PY EMR
09/26/2011 82 Drywall/Ext Lath/Gas Test AP PY
09/22/2011 17 Interior Lath/Drywall PA PY 1ST LAYER LID
09/21/2011 17 Interior Lath/Drywall NR PY
09/19/2011 16 Insulation AP PY
09/14/2011 14 Frame/Steel/BoltingN./elding AP PY
~ Cltv DI Carlsbad m Final Building lnspeCllon
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check#:
Permit#:
Project Name:
PC070087
CB080012
VIRIDIAN-LA COSTA GREENS-PHS 8
Date: 11/16/2011
Permit Type: RESDNTL
Sub Type: SFD
PLAN 3: 3953 SF LIV -700 SF GAR -231 SF DECK -175S
Address: 2357 MICA RD Lot: 41
Contact Person: Phone:
Sewer Dist: CA Water Dist: CA ..........................................................................................................................................................
Inspected $
By: e:::--7 -Date
Inspected:
Inspected Date
By: __________ Inspected: ____ _
Inspected Date
By: Inspected: ____ _
Approved: ✓ Disapproved: __
Approved: ___ Disapproved: __
Approved: ___ Disapproved: __ .......................................................................................................................................................... ,
Comments: _____________________________ _
.. 09-21-11;10: 16AM;GATEWAY INS . ;951-808-1576 # 10/ 18
LDT+
INSTALLATION CERTIFICATE CF-6R-ENV-01
Envelo e -Insulation· Roofin ; Fenestration (Page 1 of3)
Sito Address:
2357 Mica Road Carlsbad Ca 92009
Enforcement Agency; 12
If more lhcm Qne person has responsibility for imtaflation of the items on thfs certifi~te, each pirson shall prepare and ~ign a ce.rlijicole
appt1cable to the portion of construction/or wlttah they are responsible,· alternatively, the person wil/J chief responsibility for construction shall
prepare and sign this certificate/or the entire ccmstruction. All applicable Mandaiory Measures wit'1 clreck boxes ,-equire to be chtek£d 10 ensure
tht mandotorv measure:r have been me:t.
Description of Insulation
1. RAISED FLOOR
Material: BATTS Brand Name:..,G..cU,..AR,.,..D,,....IAN,,.,....,. ______ _
Thickness (inehcs):-!:'~;::,_-:--,----,------,-----,--~ Thermal Resistance (R-Value):_.,R.::-.,.J.;;i9c..._ ___ _
□ §lS0(d): Minimum R-13 insulation in raised wood-frame floor or equivalentU•factor.
2. SLAB FLOOR/PERIMETER
Material:,_.....,r,~------------Thickness (inches);, _________ _
Brand Name:. ____________ _
Thermal Resistance (R-Value): ______ _
Perimeter Insulation Depth (inches): ____ _
□ § 150(1): Water absorption rate fortbe insulation material alone without facings is no greater than 0.3%; water vapor pcrmcancc
rate is no b,reater than 2.0 perm/inch and shat! be protected frorn physical damage and lN light deterioration.
3. EXTERIOR WALL \
a. Insulation Type (e.x. Ba~ Loose Fill, Spray Foam)
BATTS
b .. Insulation Type (e.x. Batt, Loose Fill, Spray Foam)
Brand: GUARDIAN
Spray/Loose fill) Installed Acrual Thickness
(inches): ____ _
a, Thermal Resistance (R-Value): _R=.,_1.._3 ___ _
b. Thermal Resistance (R-Value): ______ _
Spray/Loose fill)
Contractor's min installed weight/ft' __ lb
Manufacturer's instnlled weight per square foot to achieve Thennal Resistance (R-Value)
□ §150(c): Minimum R-13 insulation in wood-frame wall or equivalent U-factor.
Exterior Foam Sheathing (rigid Insulation)
Material:_N=,::,A'-------,----------Brand Name: ____________ _
Thermal Resistance (R-Value) : ______ _ Thickness (inches) : ________ _
4. FOUNDATIONWALL
Material:....,...,. __________ _
Thickness (inches):. ________ _
Brand Name: __ .,....-....,,-------
Thermal Resistance (R-Value):. ______ _
5. CEILING
Batt or Blanket Type: BATTS Brand Name: ...:,aGcsUe:ARD...,.,.Ic,AN,.,_ ______ _
Loose Fill Type: ___________ Thermal Resistance (R-Value): ~Re,.-_3=8 ___ _
Spray Foam Type:__________ Brand Name: ___________ _
Installed Aorual Thickness (inches): 12 • 0 O Contractor's min installed weight/fl' ___ l.b
Manufacturer's instnlled weight per square foot to achieve Thermal Resistance (R-Value):
□ § 1 S0(a): Minimum R-19 insulation in woad-frame coiling or equivalent U-factor,
6, ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER
Material: .J.ll.<...a-----------Brand Name: ___________ _
Material:~-,-,-----------Brand Name:--~~---------
Thickness (inches):...,..-.-.--.,,...-,--,--,--Thermal Resistance (R-Valuc): ______ _
□ §ll8(a): Insulation ins111llcd meets Standards for Insulating Material.
□ §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
2008 Residential Compliance Forms August 2009
• 09-21-11; 10: 16AM;GATEWAY INS . ;951-808-1576 # 11 / 18
INSTALLATION CERTIFICATE CF-6R-ENV-01
Envelope -Insulation; Rooflmz; Fenestration (Page 2 of3)
· Site Address: I Enforcement Agency: I Permit Number:
2357 Mica Road, Carlsbad, Ca 92009
Descrintlon ofRoofin• Products
CAAC Ptoduct ID MooufDCtwur Pn,duct Roof Roof Product InitiDJ Sol11r 1'11fflnal Aced Solat
Numbet1 lnfom.,tion Brand/Model ~-A><• Slo= Wc1-'-ti k.cflft:tnncm R1dl~1uncl;!• Emittance
N/A □'
□'
□'
/, 17ie CRRC Product ID Nllmber cun be oblainedjrom tht! Cool Roo/RI.Jling Council's Rated Product Din1ctory Qf
ww.coofrooft.orglproducts/search.php
2. The weight in lbs per square feet of the roofingprod1JCt being in.rttJlltd,
J. Chee le ba:t if the Aged Rc.jlactonce Is a calculated va/11e using the equation below, footnote 4.
4. Jfthe aged rejleclance is not available in the Cool Roofkling CfJuncil':J Raled Praduct Dlrc.ctory then use tire fniltal rejlecrance value from the
direclon,Qlld 'US(! lhf! '"'uaJian (0.2+0, 7(P1n,t1gf 0.2J Jo ohJain a ca/eu/ated aetdvah~.
✓ t:JCHECKAPPLJCABlE BOK BELOW IF EXEMPT FROM71fE ROOF!NO PRODUCT "COOi, ROOF"' REQUIREMENT,
C n1e roof am covorcd by building integrated photovoltaiQ imnol:. and b1,1ilding integrated solar thermal r,anels are ex:cmpt from the above CQOI
Roof criterin.
CJ ltoof constructions that have thermal mass ov~ tho roof mcmbtane with a weight of at least 2.5 lb/fr is exempted from the above Cool Roof
criteria..
To apply Liquid Field Applied COQtings, the COQting mu.vi h(! applied wllh a minlntum dry mJ/ thickness of 20 mils across the enlire roof surface and
maat minimum -rformancc rcnu/rcmcnts /JsJed In $118(1)3 and Table I 18-C, Select tire nnn/icahle cnatinfr
D Aluminum-Piorncntcd Amhall RoofCoatin. I D Comont-Ba.«d RoofCoatin• I □other
✓ 0 CRRC-1 Lab<l Attached lo CF-jjR
(Note if no CRRC-1 lab{!/ Is wallahle, this camt,/lance method cannot he wed and another method is reauired to meet CtJmCliance).
FENESTRATION/GLAZING
Product # Total Quru,tity Add, Ex:tcrior CommwW
Manufocturcr/Brand Name U-Product of NFRC of Like Product Arca Shading Dev. Looation/ Sp<ei"1
Item IGROUP LIKE RODUCTS) factor1 SHGC1 Panes Ccrtified1•2 IQnlionaf'I ft" or Ovcrhan2 features
I N/A
2
3
4
s
6
7.
s.
/, Use valuesfromofe~trattonprod"ct's NFRCCert(fled Label. For feneJtrationproductswlthout an NFRC Jain/, u.se the default vall,esftom S,:ctlon I 16, Tab/~
116-A and 116-B of the 2008 Enl!rgJ! fJ!ith:nc)I Stamlards.
2. NFRC Labtl Ctttlflct111ts sl"'II not bf removed umll tht·bulldlm, lnsntctor has verified tire efflclencv, Enter Ye.r or No.
□ §116(a)l: Doors and windows between conditioned and unconditioned spaces designed to limit tit lea.Jcase.
□ §I 16(a)2 and 3; Act\.d fm~on ptQducts in$tnlled are equivalent to or have a tower U-factor and/or a lower SHGC than that specified on
the Certificato of Complim,e (Fonn CF-lR).
□ §l 16(a)4: Fenesttarlon products (except field-fabricated windows) havo a label listing the certified U-Factor, cortificd Solnr Heal Gain
Cooftic:ient (SHGC), and infiltration that meets tho n,quir~ents of§ 10-111 (a.)
CJ § l I 7: Ext~rior doors and windows weather-stripped; all joints and penetrations cuulktd und se.lled.
2008 Resident/al Compliance Forms August 2009
• 09-21-11;10: 16AM;GATEWAY INS. ;951-808-1576 # 12/ 18
INSTALLATION CERTIFICATE CF-6R-ENV-01
Envelone -Insulation; Roofml!; Fenestration (Page 3 of3)
Site Address: I EnCorccmcnt Agency: I Permit Number:
2357 Mioa Road. Carlsbad ca noos
DECLARATION STATEMENT
• I certify under penalty oiperjury, under the laws of the: State: of California, the information provided on this form is true and correct.
• I am eligible undt7 Division 3 of the Business and Professions Codi: to a~q,t rQSPonsibility for constructiot\ or an authorized reprcscnt.itivc:
of the person responsible for construe lion (mip1;,n5iblc:: pc:rwn).
■ I cc:rtify that the insw1lcd fe:i.tures1 materials, components, or manufactu~ dc:viccs idi:ntificd on this certificate (the inst:ill.ation) conforril9
to all applicable codes and regulations, and the: installation is cor,sis~t with the plans: and specifications approved by the enforcement
agency.
• I reviewed a copy or the Certificate of Compliance (CF-lR) fonn approved b)' the enforcement agency that id1:ntifi~ the: specific
requirements for the installation. J certify that the requirements detailed on tha CF-lR that apply to thi: installation ha.ve beea met.
• I will ensure that a completed, signed copy of thb Instnllndon Certificate 5hall be posted, or mnde avn.iloble with the bulldine
pcrmlt(s) IHued tor lhe bulldin,:, and made available to the enforcement agency for nll applicable Inspections. I undontiand tho.ta.
siped copy Or this lnstnlladon Certificate is required ro be Included with the documentation the builder provides to the bulldln~
owner at occupancy.
company Ntime: (Installing Subcontrac.tor or General Contractor or Builder/Owner}
Rockwell D all, Inc.
Responsible Pcrson•s N31110:
BUTCH INGRAM
CSLll License:
956154
2008 Residential Compliance Forms August 2009
ill ~ ■
AUC,. 19--2009 WED 12: 41 PM C !TY OF CARS LB AD FAX NO. 760 602 8558 y~ ~ {\(\ P, 01
~ d ,lil:;\ ~.:_,,,I•
~-CITY Oe
CARLSBAD
CIRCUIT CARD
B-36
Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov LOT4l
THIS. CA.RD MUST DE FILLED OUT AND AVAILABLE i\Tnra S'a'RVJCl;i J~C UlPMl!l',IT FOR THE ROUGH INSPllCTION
Address: ? 71 S.7 M/7.15. R r > Permit Numb&r: CAnP.OnJ')
Owner: MO"' n n • · ~ n r? I c If• I I Phon•: C., ''-l</:-1,LJJ l20n
Contractor: T Phone: . Arena In Sq. Ft.
l~ANTIL: ---·---~ .... ,, ' ' ., A.LC, VOLTS 0 WIRE
LOCATION CKT BKR WIRE MISC REC LTG MISC WIRE BKR CKT LOCATION SIZE SIZE TYPE REC SIZE 'IW\\ SIZE
,4/,,, 1 t./0 </: Cu. n __ ' zo 2 (' A., A1c,_
;r!u 3 <JO r -r,; I z_ ',. zu 4 n,, ;4'/ (_..
.4-/ (,,, 5 '-10 '6 p' I /7-',, 7-<) 6 (A 7 f..../7
/y/1' / 7 '1D ~ ,,,. 7' I 2--I, 7-6 8 II\, ( ·""'
F/LA 9 /c-/ 'i .. I 'I " If:, 10 Sir.,,n'l.,
(A1A 11 JC: /<' ' ..5 5 I<{ ·,. /'5'" 12 I ,ff l
-~~ ._ .'. ~ 13 ,~ ,, '
.., s (_ {, .. I< 14 /;..AtZ,-1' ,0::
13,• .J l..,, 15 IS ,,
' 2---ID 10 I /< " JC 16 fu..v 'I
W\. (l,,.-M 17 ,c /L .. // I /0 ,, -,, I< 18 £.,J'fil,._,
J:l:4-I J , 19 /,;-' ,,
" Jv I (o 5 /L ,. ;e:: 20 L;J,ft.,,.,,,,,
pe,-1-,"," 21 I$ /< . '-/ ( 7 l'-1 U-\ /S 22 C-41:n,v
it_,_,..,_ z._. 23 ,,.--%--·-j 'I:,// 7 'j /cl ~ .. l's 24 n,./,, r, 11
!'...of) fji:..'tj 25 I c::: r. 5 7 26
27 28
29 30
31 32
33 34
35 36
37 38
39 \ 40
41 42
MAIN:□ zze;-AMP BRK/FUSE O MLO Computed Load AMPS
BUS: AMP SeEI Cafcu/EJlion Work,S/lae/ on t.iack
Branch circuits required: Sl3tvica enlrance or feeder conduc1ors: A) Lighting Circuits ?.20 --3(b), 41d)
A) Size; No 8) Type: D CU DAL B) Two Small Appllence Circuits 210--11(•1
C) Insulation; 0) Conduil Size: __ C) Lnundry Circuit 220 -16(b)
Service ground/band:
B) Type: I~ [l AL
D) Central Heat!ng Equipmemt 422--12
~e:No. 7__ E) Bathroom :110 -52(d)
Cl lamp location(~):
UFER 2$0 --SO(c) RemarKs:
D Warer Pipe 250-104 ~~tod 250 -52
GFC~aiions 21 O -· B, 680 -70:
~chcn
I earl./fy tha/ all terminations have been torqued in acc6rdance with manufscturer's
~3throom{s) instruc:1/on~ and that the work shown on this circuit card represonts tha full g:,,;font of
Garagts{t:i) ~ ydroma55age'Tub thtJ work performed under !his permit.
B'Uuldoors □. ,. D Owner ~ ~~s1147a.~cl;c. AF~~ot-ected Circ. 210 -12 O Contractor:t
I. Bedroom(s) 0 Signed ,;ii, ,o
8-36 Paga 1 of 2 Rev. 03109
I
' I
I
I
AUG-1 S'-2009 WED 12: 41 PM C !TY OF CARSLBAD FAX NO, 760 602 8558 Vl,+.) b d)
f, 0 l
«~':>
~'-CI TY O c
CARLSBAD
CIRCUIT CARD
B-36
Development Service5
Building Department
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
nns (;A.RD MU!,;T BE FILLED OUT AND AVAILADLii. ,._ T T!-18 Sli.l\V1C5 ,?( UlPMJ::NT f()R 11-m ROUGH JNSrl!CTION
Address: Permit Numbor:
Owner: I Phono:
/ Phone:
Area lt'l Sq. Ft
Contractor:
!1ANTIL -----•••e• • •••••• • ....... ,, A.LC. VOLTS 0 WIRE
LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT LOCATION SIZE SIZE TYPE Sl1.fi WP\, SIZE
wAc\,..,_,,, 1 2-c) 12-(!.. q; ' 'iv 2 o.J~ '
G.o. 3 7~ IL
,, __ '6 ' .. 'IU 4 o.JQ,,,\
L)v-J 5 7_, 12-' .. I z_ (',. lo 6 l6r
r-1\ i { 7 'Z.<) I z_ ,. w 12-r .. -Z.o 8 K.iJ C..ri
\.)-,,,n C'\ 9 '2-c) /1-.-'-I I z_ ~u 2-c, 10 V ,+ GI"\
D•,f'lL--11 kJ I z. " <{ '{ /Z. ' .. z.-v 12 h+-Gpi
_Yj_t)L, 13 -z..:, [z_. r,. l/ 'f 1 'Z-.. Lu 14 k.; +-C.,p,
U:llcl"" 15 ,~ f'I /',. 7 .7 5 5 I' ·., I,;-16 rhv'< tf"<\
lufrLJ., 17 /c; / '-( ¼ I '1, '1 7 l'-i ·, /(, 18 ~ /,,vi
19 20
21 22
23 24
25 26
27 28 -----·· 29 30
31 32
33 34
35 36
37 38 --39 \ 40 ---41 . 42
.
MAIN:□ zz.r AMP BRK/FUSE O MLO Computed Load AMPS
BUS; AMP See Catcu/Dlion Woril'.$/1eel on back
Branch circuits required: ServicG enlrance or leader conduc1ors: A) Lighting Circuits 220 -3(b), 4(d)
A) Size; No. 8) Type: 0 CU DAL B) Two Sm9ll Appliance Circuits 210-11(•1
C) Insulation: 0) Conduit Size: ___ C) Laundry Circuit 220-16(b)
Serv(ce ground/bond;
~]AL
D) Central Healing Equipmant 422-12
A) Size: Na. L B) Type: E) Bat))raom :l10 -52(d)
~mp location(,):
UFER 250 -SO(c) RemarKs:
D Water Pipe 250-104 V"~Rod 250 -52 ·5
J csrtlfy ,he( al/ lerminations have Deen torquod in accOrdance with manu'faciuter's GF~lions 210 -· 8, 680-ID:
3throom(s) IJl-1(\lch<m instruc:1fon,!; and that the work shown on this circuit card rcpresonts tha full QX/er,t of
[F'Garaga(::;) [9+<{ydromassage'Tub 1/le work porformed under !his permit.
~!doors □ L D Owner
AFC=c\ed C1rc, 210 -~2 lJ Contractor~~~'l;: r edroorn(s·) 0 Signed ~ Date
------
8-36 Pags 1 ot 2 Rev, 03/09