Loading...
HomeMy WebLinkAbout2358 GEODE LN; ; CB061310; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 O'Sc01-2'007. Residential Permit Permit No: CB061310 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: 2358 GEODE LN CBAD RESDNTL 2132720600 Sub Type: SFD Status: Lot#: 33 Applied: Valuation: $359,132.00 Construction Type: VN CT04-15 Entered By: Occupancy Group: 08/01/2007 # Dwelling Units: Reference #: Structure Type: SFD Issued: Bedrooms: 3 Bathrooms: 3 Inspect Area: Project Title: CAMBRIA.@THE GREENS,PLN4,MDL Orig PC#: 3217 SFD,602 SF GAR,108 SF CV PORCH,109 SF DECK Plan Check#: Applicant: CUMMINGS ROBERT STE 170 420 STEVENS AV SOLANA BEACH CA 92075 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee $1,347.36 $0.00 $875.78 $0.00 $0.00 $35.91 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3,188.00 D5/8 $201.00 $0.00 Owner: K HOVNANIAN COMPANIES STE 100 5900 PASTEUR CT CARLSBAD CA 92008 760-944-9012 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES ISSUED 04/06/2006 KG Plan Approved: 08/01/2007 PC060017 $0.00 $160.00 $4,313.00 $1,745.90 $6,536.20 $0.00 $0.00 $0.00 $720.00 $0.00 $0.00 $210.00 $66.25 $88.00 $0.00 $0.00 $0.00 $0.00 $1,936.00 $179.00 $21,602.40 Total Fees: $21,602.40 Total Payments To Date: $21,602.40 Balance Due: $0.00 Inspector: FINAL APPRo/_}L Date 1/-~v'cf--c1earance: :::,. \~•e>X NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with thls project. NOR DOES IT APPLY to any f I x i n f i h h v r i I n iv n N Tl E imi r h' f Ii i ----·-City of Carlsllall ~--~ Flnal Bulldlnu 1ns11c111n MAR 2 4 Dept: Building Engineering Planning CMWD St Lite Fire Plan Check#: Date: 03/24/2008 Permit#: CB061310 Permit Type: RESDNTL Project Name: CAMBRIA.@THE GREENS,PLN4,MDL Sub Type: SFD 3217 SFD,602 SF GAR,108 SF CV PORCH,109 SF DECK Address: 2358 GEODE LN Contact Person: WALLY Sewer Dist: CA Inspected ~',. By ('~~ Inspected By: Inspected By: Phone: 6194547840 Water Dist: CA Lot: 33 Date '3/zs-l t'Yl, Approved: Inspected: Date Inspected: ~i~~asz Approved: -f- Date Inspected: Approved: Disapproved: ~ Disapproved: __ Disapproved : __ Comments:------------------------------- April4,2008 TO: Wally Reed, KHovnanian Homes, phone: (619) 454-7840, e-mail: wreed@khov.com Corey Funk, Assistant Planner Christine W auschek, Building Department Janean Hawney, Building Department Pete Dreibelbis, Senior Building Inspector Michele Masterson, Management Analyst Meghan Jacobson, Senior Office Specialist FROM: Michael Elliott, Landscape Architect Consultant to the City of Carlsbad (760) 944-8463 PELA file: 322 -Villages of La Costa -1.07 -(Lots 33-35) -lnspl REFERENCE: I st Landscape Inspection PROJECT: Villages of La Costa, The greens 1.07 Project Number: CT04-15 Drawing Number: 427-6L Lot 33 -2358 Geode Lane-CB061310 Lot 34 -2354 Geode Lane -CB061312 Lot 35 -2350 Geode Lane -CB0613 l l The following items were noted as deficient and in need of correction: Lot 33 -2358 Geode Lane -CB061310 I. Install 3 missing Leptospermum shrubs on the rear slope. 2. Permit card was not signed. Lot 34 -2354 Geode Lane -CB061312 I . Landscaping is approved. 2. Permit card was signed. Lot 35 -2350 Geode Lane -CB061311 I. Install I missing Leptospermum shrub on the rear slope. 2. Permit card was not signed. The contractor/developer is reminded that irrigation record drawings (as-builts) will be required to be completed and approved by the City prior to signing off the last unit of the project. The contractor is to call Mike Elliott at (760) 944-8463 for a follow-up inspection when the above items are completed. From: To: CC: Date: Subject: Hi Christine, Constantine Abalos Christine Wauschek Dale Willis 04/16/2008 10:49 AM Re: Cambria @ the Greens final inspection I just signed all 3 lots yesterday. They are good to go. You called at the right time. Thanks Cons >>> Christine Wauschek 4/16/2008 9:53 AM>>> Cons, back on March 25, 2008 I received a disapproval from you on the final inspection of lots 33, 34, and 35 out at cambria@ the Greens. The building inspector has given his final approval; are you OK with these houses now? OK for me to give them their gas meters7 Christine Inspection List Permit#: CB061310 Type: RESDNTL SFD CAMBRIA.@THE GREENS,PLN4,MDL 3217 SFD,602 SF GAR,108 SF CV PORCH, Date Inspection Item Inspector Act Comments 04/15/2008 89 Final Combo RI 04/15/2008 89 Final Combo RB AP will not be used as model 03/25/2008 89 Final Combo RB co 03/24/2008 89 Final Combo RB CA 01/08/2008 39 Final Electrical RB AP EMR 10/31/2007 82 Drywall/Ext Lath/Gas Test PD AP 10/25/2007 16 Insulation RB AP 10/25/2007 84 Rough Combo RB AP ON CO 10/17/2007 84 Rough Combo RB co 10/09/2007 13 Shear Panels/HD's RB AP 10/09/2007 15 Roof/Reroof RB AP 10/04/2007 13 Shear Panels/HD's RB co 09/28/2007 15 Roof/Reroof RB PA OK TO LOAD ROOF 09/13/2007 15 Roof/Reroof RB co & RESUBMIT TRUSSES RE-WALK EVERYTHING 08/13/2007 11 Fig/Foundation/Piers TP AP 08/13/2007 12 Steel/Bond Beam TP AP 08/06/2007 21 Underground/Under Floor RB WC 08/06/2007 22 Sewer/Water Service RB co ON WATER SERVICE 08/03/2007 21 Underground/Under Floor RB CA BY JOEY 08/03/2007 22 Sewer/Water Service RB CA 08/02/2007 21 Underground/Under Floor RB AP has BWV 08/02/2007 22 Sewer/Water Service RB PA SEWER ONLY Wednesday. April 16, 2008 Page 1 of 1 City of Carlsbad Bldg Inspection Request For: 04/15/2008 Permit# CB061310 Inspector Assignment: RB --- Title: CAMBRIA.@THE GREENS,PLN4,MDL Description: 3217 SFD,602 SF GAR,108 SF CV PORCH,109 SF DECK Sub Type: SFD Type: RESDNTL Phone: 6194547840 Job Address: Suite: Location: 2358 GEODE LN Lot APPLICANT CUMMINGS ROBERT 33 Owner: K HOVNANIAN AT LACOSTA GREENS LL C Remarks: Total Time: Act Comment Inspector: ----- Requested By: WALLY Entered By: KATHY CD Description 19 Final Structural /J..t tv:,/1 ~ f--tL UJ~d'. Cl~ 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Comments/Notices/Holds Associated PCRs/CVs Original PC# PC060017 PCR07160 ISSUED CAMBRIA-CONSTRUCT CHANGES; EFFECTTVE MODELS & ON PCR07182 ISSUED CAMBRIA-MINOR FRAMEWORK; CHANGES REPLACES ALL PREVIOUS PLANS Inspection History Date Description Act lnsp Comments 03/25/2008 89 Final Combo co RB 03/24/2008 89 Final Combo CA RB 01/08/2008 39 Final Electrical AP RB EMR 10/31/2007 82 Drywall/Ext Lath/Gas Test AP PD 10/25/2007 16 Insulation AP RB 10/25/2007 84 Rough Combo AP RB ONCO 10/17/2007 84 Rough Combo co RB 10/09/2007 13 Shear Panels/HD's AP RB 10/09/2007 15 Roof/Reroof AP RB 10/04/2007 13 Shear Panels/HD's co RB 09/28/2007 15 Roof/Reroof PA RB OK TO LOAD ROOF 09/13/2007 15 Roof/Reroof co RB & RESUBMIT TRUSSES RE-WALK EVERYTHING City of Carlsbad Bldg Inspection Request For: 10/17/2007 Permit# CB06131 O Inspector Assignment: RB --- Title: CAMBRIA.@THE GREENS,PLN4,MDL Description: 3217 SFD,602 SF GAR,108 SF CV PORCH,109 SF DECK Type: RESDNTL Sub Type: SFD Phone: 7606777302 Job Address: 2358 GEODE LN Suite: Lot: 33 Location: Inspector: ----- APPLICANT CUMMINGS ROBERT Owner: K HOVNANIAN AT LACOSTA GREENS LL C Remarks: Total Time: Requested By: JOEY Entered By: CHRISTINE CD Description Act Comments 14 Frame/Steel/Bolting/Welding ~ 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers Comments/Notices/Holds Associated PCRs/CVs Original PC# PC060017 PCR07160 ISSUED CAMBRIA-CONSTRUCT CHANGES: EFFECTIVE MODELS & ON PCR07182 PENDING CAMBRIA-MINOR FRAMEWORK; CHANGES REPLACES ALL PREVIOUS PLANS I ns12ection H isto[II Date Description Acl lnsp Comments 10/09/2007 13 Shear Panels/HD's AP RB 10/09/2007 15 Roof/Reroof AP RB 10/04/2007 13 Shear Panels/HD's co RB 09/28/2007 15 Roof/Reroof PA RB OK TO LOAD ROOF 09/13/2007 15 Roof/Reroof co RB & RESUBMIT TRUSSES RE-WALK EVERYTHING 08/13/2007 11 Ftg/Foundation/Piers AP TP 08/13/2007 12 Steel/Bond Beam AP TP 08/06/2007 21 Underground/Under Floor WC RB 08/06/2007 22 Sewer/Water Service co RB ON WATER SERVICE 08/03/2007 21 Underground/Under Floor CA RB BY JOEY 08/03/2007 22 Sewer/Water Service CA RB 08/02/2007 21 Underground/Under Floor AP RB has BWV flrlf..) -1 SAN DIEGO AREA RESIDENTIAL CIRCUIT CARO ANO LOAD SUMMARY (1990 NEC) THIS CARD MUST BE FllLEO OLIT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE ROUGH INSPECTION A DDRESS .2..~'18 G&o.o!F L,A/ PERMIT 1 C-,6 o 6 J,_3/{) OWNER PHONE CENSUS TRACT I CONTRACTOR PHONE AREA IN SO. FT. ..3,J8'"v' PANEL MAIP A.I.C. VOLTS 0 WIRE BJCR WIRE MISC LTG WIRE BKR LOCATION CJCT SIZE SIZE TYPE LTO REC REC MISC SIZE TYPE SIZE CJCT l..OCATION ./)/NI)./ t, I r}.b /~ Ct.I <./ !/ /1.,, UI ,:u) 2 APP✓t. AP..P'l-3 ~t,' /'2..., Ct,/· V 'cf-/"7J CL,/ f).o • ,Ar'f''l- ,r'I r~ft) ' /.(" It./, CL/ e ,. , q 1.(/ w /q 6 ,t, re.,;JeP/ )Jbt;{, &>All. -6FI -tJP 7 1.r 1¥ CCI ,;;J. (p , I l cJ ca '" • s ~ <./ . .n I 8 II l,L),+.f H lf'IL 9 1-D /"1./ ca I I f L c.(I 'J,-u 10 a ,,PtSPdcf,'/l_ Iv/ I C/lOW At.le II ~ ~ CL/ I I B <:,{./ '/Z 12 0{/6µ b) ~ Ct>tJ l£fl-. 13 ~<) /"LJ cLI I I 0 CL,/ ~ 1, Ale../ llEF~lt.-1$ ~<l ,~ ct/ z, 7.. /~ c:u ~ 16 /looLJ //efJ t,) re-60~ 11, 17 fljo 1.. /1L. II 19 20 21 22 23 24 2$ 26 77 21 29 30 31 32 33 34 3S 36 37 31 39 40 41 42 MAIN: • ,2.1,,< AMP BKR/FUSE 0MLD COMPUTED LOAD /2< AMPS BUS: AMP s-C&lculalion WorMllNI on tack. SERVICE ENTRANCE OR FEEDER CONDUCTORS: BRANCH CIRCUITS REQUIRED: A) SIZE: NO. 8) TYPE:• OJ •Al · ~ UGKTING CIRCUITS 220 • 3(b). 4(d) B) TWO SMAU APPI..IMICE CIRCUITS 220. "(b) C) NSIJL.ATION: C) LA~OAY CIRCUIT 220 • 4(c) · D) CQ,IOUTT SIZE: D) CENTRAL HEATING EQUIPMENT 422-7 · SERVICE GROUND/BONO: A) SIZE: NO. f,I 'L,,-B) m'E: 0 OJ • Al. REMARKS C) CLAMP LOCATION(S): 0 LfEA 250 -81(c) 0" WAT'ffi f>PE 250 • 80(ia), 111 (a) • CRX.N)R:X) 250 • 83(c) I caf1i ly 1h11 t all lllmi ra lion, have been !Dtqued in ac:coraance w,i,, ,,..,._, tac~, w'a inalructions and 11'11l lhll work ahown on lhi, cirruit card rap,eaenll lhll lvl • ex lanl o t 1h11 -ril perlc,m.d under ll'lia perm L .• GFCI LOCATIONS 210:.8, 680-70: 0 OWNER 0' BA'THFIClD,I (S) 121' KTT'Ctt:H D COITTRACTO~ cceCT~/o Co .,£1 GARAGE (S) • HYOAOMASSAGE rue • SIGNED , • ~ DATE /D 17-oz REFERENCE San [);eoo E!ecn:al ~ 21 ~5 SAN DIEGO AREA RESIDENTIAL CIRCUIT CARD ANO LOAD SUMMARY (1990 NEC) THIS CARD MUST BE Fll LEO OUT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE= ROUGH INSPECTION OWNER PHONE CENSUS TRACT I CONTRACTOR PHONE AREA IN SO. FT. d, ~ fl Z,,, PANEL <S'tlil:) ____ A.I.C. ______ VOLTS ---0---WIRE LOCATION BJCR WIRE CJcr SIZE SIZE TYPE MISC LTG REC REC LTG WIRE BKR CKT MISC SIZE TYPE SIZE LOCATION 1 1-r I</ at /.AttfJOP,f 5 1 .. r 1/J C£/ 7 /a /(/ a/ 11 /J' 1<.L eLA IJ ,~ I/¢' cP 17 19 21 23 2S n 29 31 33 3S 37 39 ,1 MAIN: • AMPBKR/FUSE •MW BUS: AMP SERVICE ENTRANCE OR FEEDER CONDUCTORS: A) SIZE: NO. ____ B) TYPE: • aJ • AL · C) INSULATION: ___ _ D) CONDUTT SIZE: ___ _ SERVICE GROUND/BOND: A) SIZE: NO. ____ B) TYPE: • aJ • AL C) Cl.AMP LOCATION($): • u=m • WATEAPF'f • GFO.H)fn> • GFCI LOCATIONS 210-8, 680-70: D BATHROOM (S) • • GARAGE (S) 250 • 81(c) 250 • l!O(a), 111 (a) 250 • 83(c) D • • HYDAOMASSAGE TUB REFERENCE San Di8QO Elec:1rical ~ 21S-5 :;.., 7 I ;_ q ;,; II <j II 7 , I '/, ~ 7 ~ ? I 16 II 20 22 24 26 21 30 32 34 36 31 ,o ,2 COMPUTED LOAO-------AMPS See Calculalion Won<ahMI on bad,. BRANCH CIRCUITS REQUIRED: ~ LXiHTING CIRCUITS 8) TWO SMAU. APPLIANCE CIRCUITS C) lAu,jORY CIRCUIT 0) CENTRAi.. HEATING EQUIPMENT 220 · 3(b), 4(d) 220. 4(11) 220 • 4(c) · '22-7 . REMARK$ ______________ _ I certify Iha t all tarm nation, have beet, tctqoed in accordance wilh manufac'-' ,.,.a inatructiol'\I and lhll Iha work ahown on lhi• circuit cart! rap,awnta Iha lul .. tent ol the wort< ~m.d under !his pemil • OWNER -----....,..,.......-,-....,........,,,--....,,....,,_..---0 CONTRACTO~ Ebtx:Tfl-lO cL). SIGNED --~~;,,.-,,.,,__--,,-H--...,,..-=-------- DATE 7 1° -17-o"J ' , .... SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION OPTIONAL METHOD NEC 220-30 As an alternative method, the STANDARD METHOD, found in ARTICLE 220 of the National Electric Code, may be used 1. GENERAL LIGHTING LOADS Dwelling .3,,,?87.,,, sq. ft. x 3 YA= /01lfl~ VA Small appliance loads -220-16 (a) 1500 VA x Lcircuits = ~,ooo YA Laundry load-220-!6(b) 1500 VA x . circuits= /, roD VA General Lighting Total / 7 6 'f v VA 2. COOKING EQUIPMENT LOADS· Nameplate Value Range ____ VA= ___ VA Cooktop ____ y A= Oven(s) . VA = YA --.fO~o"""D-,--VA Cooking Equipment Total ,.roDiJ VA 3. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer _____ VA= DryerTotal ___ VA 4. FIXED APPLIANCE LOADS 230-30(b3) Dishwasher= Disposal= ,c~mF :•sr -t,,.). cot>lE/l., Water Heater= Hydromassage Bathtub = Microwave Oven = Built-in Vacuum= YA .VA VA ___ VA -~-YA /,{O<J VA -,--~YA /:i:FG'fv J,,rvo Y.A Fixed Appliance Total LO s1 z... VA S. OPTIONAL SUB TOT AL (Add all of the above totals) 6. APPL YING DEMAND FACTORS -TABLE 220-30 . . . { Pint 10,000 VA x 100% = Opoonal Subtotal (from line 5) Remaining /~ (p ze y A x 40% = 7. HEATING OR AC LOAD· TABLE 220-30 Larger of the Heating or AC Load = 8. OPf:ONAL LOADS TOT AL (Add totals from lines 6 and 7) = 9. MINIMUM SERVICE SIZE= Optioniio ~o~ Total = (Please put total on front of card under Computed Load) .2i~1 B VA 10,000VA ?B':7{ VA :i. ZBZ I YA /2.r Ampere SOUTHWEST INSPECTION AND TESTING INC. D~ 441 COMMERCIAL WAY \'-., LA HABRA, CA 90631-6168 562-941-2990 714-526-8441 Fax-562-946-0026 -------------------------------------------=-=------=-=-====-====-=-======-====- FIELD DATA ON TEST SPECIMENS ASTM C31, Cl38, Cl43, Cl72, Cl73, C231, Cl064 CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 2358 GEONE LN. CARSLBAD JOB NAME: CAMBRIA/ 04-15/ MODEL ARCHITECT: BGA JOB#: 70198 DATE: 9/22/2007 PERMIT#: CB06-1310 ISSUED BY: ENGINEER: GOUVIS ENGR. CONTRACTOR: K. HOVNANIAN SUB CONTRACTOR: DIAZ CONCRETE LOCATION IN STRUCTURE: SLAB/ LOT#33 CONCRETE SUPPLIER: SUPERIOR PLANT: 1 TYPE OF CEMENT: V ADMIXTURE: WRDA-64 SLUMP : 5" WATER ADDED: 15 GAL. CONCRETE TEMP: 78 F MIXING TIME: 105 MIN. MIX#: 8375P TICKET #: 90082 AIR TEMP: 70 F TIME CAST: 11:55 DATE CAST: 8/14/2007 SPECIMENS MADE BY: CLYDE LACHER RECEIVED AT LAB: 8/15/2007 SPECIFIED PSI: 4500 FIELD IDENTIFICATION! A LAB IDENTIFICATION : 708976 AGE DAYS DATE TEST SIZE -IN. AREA-SQ.IN. CRUSH LOAD-LBS COMP-STR. -PSI. I H/D CORR FACTOR CORR. STR. -PSI TIME TESTED BREAK TYPE C.T.M. USED REMARKS: 7 8/21/2007 4 X 8 12.57 47950 3815 FORNEY B : 708976 28 9/11/2007 4 X 8 12.57 66330 5280 FORNEY C : 708976 28 9/11/2007 4 X 8 12.57 66960 5330 FORNEY COMPLIES: X ASTM C39, Cl74, Cl92, C470, C617, C42 DOES NOT COMPLY: D E THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING SAMPLES CAST BY OTHERS: ASTM C39 BREAKS A= cone I ,_? / . /" _,,.// ,--1.'J:ttnifu · p::-~ / LAB.,~~ B;/4ne and spl~---C= cone D=shear E=columnar -----------•-·· ...... .