Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2365 CAMINO VIDA ROBLE; B; CBC2019-0477; Permit
ity of Car-Isbad Commercial Permit Print Date: 02/24/2020 Permit No: CBC2019-0477 2365 Camino Vida Roble, B BLDG-Commercial 2130502700 $53,951.60 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: if Dwelling Units: Bedrooms: Project Title: Description: Work Class: Lot if: Reference if: Construction Type: Bathrooms: Orig. Plan Check if: Plan Check if: Tenant Improvement Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Closed - Finaled 10/07/2019 01/14/2020 LStor 2/24/2020 2:25:30PM STRATA SKIN SCIENCE: 546 SF TI WAREHOUSE TO OFFICE II ADD DEMSING WALL TO CREATE 3 ROOMS Owner: F R NATIONAL LIFE LLC 898 N Sepulveda Blvd, Ste 750 ELSEGUN DO, CA 90245 BUILDING PERMIT FEE ($2000+) . $423.72 BUILDING PLANCHECK FEE (BLDG) $296.60 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL . $60.00 FIRE Plan Review Per Hour - Office Hours $272.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $45.00 5B1473 GREEN BUILDING STATE STANDARDS FEE . $3.00 SEWERBENEFITAREAFEES - G $143.83 SEWER CONNECTION FEE (General Capacity all areas) $186.58 STRONG MOTION-COMMERCIAL $15.11 TRAFFIC IMPACT Commercial-Industrial Outside CFD $1,224.00 Total Fees: $2,669.84 Total Payments To Date: $2,669.84 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition. of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section, 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. . You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or servicefees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov COMMERCIAL Cr (2Qq6LI7- Plain Check City Pl of BUILDING PERMIT __________ Est. Value M S31 157. O Carlsbad APPLICATION PC Deposit Date Job Address 2.3C..S Cai,1 't li. 441 le Suite: B APN: Zi 3 —0S0— 2 Tenant Name: 9'k-q.1i S' k'R cie Cf CT/Project #: Lot #:________ Occupancy: Construction Type: Fire Sprinklers:,1 / no Air Conditioning: 3i no BRIEF DESCRIPTION OF WORK: /_/_ Lda,-e J Addition/New: New SF and Use, New SF and Use, Deck SF, _________ Patio Cover SF (not including flatwork) Tenant Improvement: 3'9 SF, Existing Use Proposed Use SF, Existing Use Proposed Use J Pool/Spa: SF Additional Gas or Electrical Features? EJ Solar: KW, _____ Modules, Mounted Tilt: Yes / No, RMA: Yes / No, Panel Upgrade: Yes / No El Plumbing/Mechanical/Electrical Only: El Other: APPLICANT (PRIMARY) PROPERTY OWNER Name:Ci1twI-'& P14( (DhdrLtAB Name: 1a ''kih 'L,',c.QI Address: Address: 2.-75 ('a&. i' 1/i'1 100 City: State: Zip: City: earlr Ia I State:('3i Zip: '2O 11 Phone: Phone: Email: & Email:___________________________ DESIGN PROFESSIONAL Name: Go.,'-I &ovc' Address: '3_P 'L)4-__i1yaf4.J' :City: F4Ilhtøk State: _Zip: '1W19 Phone: _7O 12.,3ciq Email: J5v..5 stcs,cL/.v4 Architect State License: CONTRACTOR BUSINESS Name: Cc, I ;q 4 A-C-Coç Lb.. c. Address: Lj'I2.00 hiiq 94 City: TevecuI4 State:C'i Zip: °LS'tL Phone: -11q 317 ci &r Email: M 1 k/Ic. Q 't(h - State License: 51(!,! Bus. License: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-2 Page 1 of 2 Rev. 06/18 (OPTION A): WORKERS'COMPENSATION DECLARATION: hk I hearby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. 0 I haveand will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: Policy No. Expiration Date: .Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: iI'7O/7//' DAGENT DATE: (OPTION 13 ): OWNER-BUILDER DECLARATION: Ihereby affirm that lam exempt from Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects withcontractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 Yes 0 No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address / phone/type of work): OWNER SIGNATURE: DAGENT DATE: CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: Leader's Address: ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is:the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration fom or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes ,No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes ONO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over5'O' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 davj.(ectign 106.44 UnifoLn ng (ode). APPLICANT SIGNATURE: DATE: /77 7 1635 Faraday Ave Carlsbad, p(92008 0/'760-602-2719 Fax: 760-602-8558 Email: BuiIdingca rlsbadca.gov B-2 Page 2 of 2 Rev. 06/18 Permit Type: BLDG-Commeràial Application Date: 10/07/2019 Owner: F R NATIONAL LIFE LLC Work Class: Tenant Improvement. Issue Date: 01/14/2020 Subdivision: CARLSBAD TCT#79-01 Status: Closed - Finaled . Expiration Date: 08/10/2020 Address: 2365 Camino Vida Roble ,B Carlsbad, CA 92011-1505 IVR Number: 22245 Schedulid Actual Date Start Date' lnspection.Type Inspection No. Inspection Status Primary lnspeótor Reinspection complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Plumbing Final . No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final . . No II February 24, 2020 Page 2 of 2 Permit Type: BLDG-Commercial Application Date: 10/07/2019 Owner: FR NATIONAL LIFE LLC Work Class: Tenant Improvement . Issue Date: .01/14/2020 Subdivision: CARLSBAD TCT#79-01 Status: Closed - Finaled Expiration Date: 08/10/2020 . Address: 2365 Camino Vida Roble , B IVR Number: 22245 Carlsbad, CA 92011-1505 Actual Scheduled Sta rt te Inspection Type Inspection No. . Inspection Status Primary Inspector Reinspection Complete Dite 0111712020 01117/2020 BLDG-14. 116758.2020 Passed Luke Storno Complete FrameiSteel!Boltin glWelding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency . . No BLDG-34 Rough 116757.2020 Passed Luke Storno Complete Electrical Checklist Item . COMMENTS . Passed BLDG-Building Deficiency Wall frame approved No Ok to insulate and drywall. 01/22/2020 01/22I2020 BLDG-16 Insulation 1169212020 Passed Luke Storno Complete Checklist Item . COMMENTS ( Passed BLDG-Building Deficiency . No BLDG-17 Interior 116922-2020 Passed . Luke Storno Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/06/2020 02/06/2020 BLDG-Fire Final 1187432020 Passed Adalmira Maldonado. . Complete Checklist Item COMMENTS Passed FIRE- Building Final . • Yes 02/10/2020 02/10/2020 BLDG-85 T-Bar, 118957.2020 . Failed Michael Collins Reinspection Complete, Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready. Complete all trades . No 02/11/2020 02/I1I2020 BLDG-85T-Bar, 119079.2020 Passed Michael Collins Complete Ceiling Grids, Overhead . Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready. Complete all trades No . BLDG-14 Conference & R&D rooms only. See card. -Yes Frame-Steel-Bolting-Welding (Decks) . BLDG-34 Rough Electrical . . Yes BLDG-44 . . Yes Rough-Ducts-Dampers 02/24/2020 02/24/2020 BLDG-Final •. 120102.2020 Passed Luke Storno . . Complete Inspection . . . • . February 24, 2020 .( Page.I of 2 EsGil A SAFEbuitt Company DATE: 12/5/2019 JURISDICTION.âjI1bidTh PLAN CHECK #.: CBC2019-0477 SET:!! PROJECT ADDRESS: 2365 Camino Vida Roble PROJECT NAME: Strata Tenant Improvement APPLICANT JURIS. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. EJ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. LI EsGil staff did advise the applicant that the plan check has been completed. • Person contacted: Telephone #: Vntactefla~!%~ (byy,') Email: ilaTelephone Fax In Person LI REMARKS: By: Jason Pasiut Enclosures: EsGil 11/21/2019 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad CBR2019-3277 12/5/2019 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK #.: CBR2019-3277 PREPARED BY: David Yao DATE: 12/5/2019 BUILDING ADDRESS: 7709 Garboso Place BUILDING OCCUPANCY: R3/U BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) remodel est. 20,000 Air Conditioning Fire Sprinklers TOTAL VALUE 20,000 Jurisdiction Code 1cb IBY Ordinance Bldg. Permit Fee by Ordinance [j Plan Check Fee by Ordinance Li] Type of Review: P Complete Review Structural Only O Repetitive Fee [jJ Repeats r p. 0 Other Hourly 1H1 @ * EsGil Fee I p. I $132.141" Comments: Sheet of V/ EsGil A SAFEbuiItCompany DATE: 10/16/2019 U APPLICANT U JURIS. JURISDICTION: Carlsbad PLAN CHECK #.: (CBC20I9-0477 SET:i PROJECT ADDRESS: 2365 Camino Vida Roble PROJECT NAME: Strata Tenant Improvement The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. L The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: California AAC Construction LI EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: California AAC Construction Telephone #: 714-317-5165 Date-cotcteç 1(by:rj,) Email: californiaaac@msn.com Mail Telephone ) Fax In Person LI EMARKS: By: Jason Pasiut Enclosures: EsGil 10/8/2019 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 19-0477 10/16/2019 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK #.: CBC2019-0477 JURISDICTION: Carlsbad OCCUPANCY: B, S-i USE: Office, Storage TYPE OF CONSTRUCTION: V-A ACTUAL AREA: 1,160sf ALLOWABLE FLOOR AREA: complies STORIES: HEIGHT: unchanged SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 10/7/2019 DATE INITIAL PLAN REVIEW COMPLETED: 10/16/2019 OCCUPANT LOAD: 2i DATE PLANS RECEIVED BY ESGIL CORPORATION: 10/8/2019 PLAN REVIEWER: Jason Pasiut FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC20 19-0477 10/16/2019 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0477 PREPARED BY: Jason Pasiut DATE: 10/16/2019 BUILDING ADDRESS: 2365 Camino Vida Roble BUILDING OCCUPANCY: B, S-i BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 1160 46.51 53,952 Air Conditioning Fire Sprinklers TOTAL VALUE 53,952 Jurisdiction Code Icb ]By Ordinance 1997 USC Building Permit Fee [] 1997 UBC Plan Check Fee [] Type of Review: W Complete Review r Structural Only r Repetitive Fee , Repeats p. r Other r Hourly EsGil Fee r 1@* I $272.231 Comments: Sheet 1 of 1 Carlsbad CBC20 19-0477 10/16/2019 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. . PLANS Each sheet of the plans must be signed by the person responsible for their preparation, even if there are no structural changes. California State Law. Provide an updated Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Stories Define storage room as S-I or S-2 and show rated wall details between the S and B occupancies if applicable. (mainly if the storage is S-2) . ACCESSIBILITY FOR REMODELS, ADDITIONS, AND REPAIRS The following disabled access items are taken from the 2016 edition of California Building Code. Per Section 1.9.1.2, all privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. Where existing elements or spaces are altered, each altered element or space shall comply with applicable requirements of Division 2, including CBC section 11 B-202.4. CBC section 11 B-202.4 states that when alterations or additions are made to existing buildings, an accessible path of travel to the specific area of alteration shall be provided. See exceptions to 11 B-202.4. Detail on the plans the following elements of the existing path of travel that are required to comply with the 2016 accessibility standards: Carlsbad CBC20 19-0477 10/16/2019 5. Existing primary path of travel to the building or facility entrance, including: The accessible parking dimensions, slope, and cross-slope in compliance with CBC 11 B-502. The access aisle dimensions, slope, and cross slope in compliance with 11 B-502.3. The location of detectable warnings at hazardous vehicle areas. 1113- 705.1.2.5. The curb ramp (if any) 48" minimum width, 48" x 48" turning space at the bottom, landing length of 48" at the top, slope and cross-slope in compliance with CBC 11 B-406. The ramp (if any) slope, cross-slope, 48" minimum width, 60" x 60" landing at the top, 72" long landing at the bottom, compliant changes in direction (60" x 72") in compliance with CBC 11 B-405. f The stair (if any) width, riser and tread dimensions, contrasting stipes, handrail height, gripping surfaces and top/bottom extensions in compliance with CBC 11 B-504 and 505. Show that the walking surface from the access aisle to the building entrance complies with slope, cross slope, changes in level and clear width provisions of 11 B-403. Show the accessible entrance door threshold, door hardware, door width, and maneuvering clearances on either side of the door in compliance with CBC 11 B-206.4. 6. the "van accessible", "250 fine", and "unauthorized vehicle parking" signs per 1113- 502.6, 11 B-502.6.2, 11 B-502.8.2. Existing accessible parking surface identification. 11 B-502.6.4.1. Existing access isle "NO PARKING" identification per 11 B-502.3.3 Provide the address and phone number for the location to reclaim towed vehicles. 11 B-502.8.2. 7. Show directional signs at the following locations when the means of egress are not accessible. 1009.10 a. At exits serving accessible spaces but not providing an accessible means of egress. 0 MECHANICAL / ELECTRICAL / PLUMBING Carlsbad CBC20 19-0477 10/16/2019 8. Please indicate if the mechanical system will be installed new or is existing and being altered. If so, please provide complete plans. Please provide the required MECH forms to show energy compliance. The MECH forms shall be signed and imprinted to the plans. If new: Show on the plans how the installation of new mechanical equipment on the roof will meet the seismic design requirements of ASCE 13.2.1 general design, 13.4 anchorage, and applicable section of 13.6 unless exempted by 13.1.4. Show on the plans that the existing structural framing is sufficient to support the weight of the new RTU being installed. CMC 303.8. A GFCI protected receptacle outlet is required within 25 feet and on the same level as the mechanical equipment (heating, air-conditioning, and refrigeration equipment). Please include on the plans. NEC 210.63. A readily accessible electrical disconnecting means shall be shown within sight of the equipment. CMC 303.8.5. 9. Please indicate if the electrical system will be altered. If so, please provide complete plans including electrical load calculations and panel schedules that indicate new and existing loads. a) Complete the panel schedule to show total kva and watts not in excess of bus rating. 10. Please indicate if the plumbing system is to be altered. If so, please provide complete drain, waste, and vent plans showing pipe sizes, fixture vents, and connection to existing systems. ENERGY CODE REVIEW 11. Demising wall insulation: The insulation installed at demising walls of non- residential buildings shall have an R-13 value. ES 110.8(f). 12. Multilevel lighting controls are required in areas exceeding 100 square feet in area and have a connected general lighting load exceeding .5 watts per square foot (Classrooms are .7 watts). Review ES Table 130.1-A for design requirements. Include control placement and design on the floorplans. (AB switching no longer complies for most fixture types). 13. Shut-Off Controls: Each floor, each space (not exceeding 5,000 square feet), and each type (general, display, and ornamental) of lighting shall be individually capable of being automatically shut-off when the building is unoccupied. Include the control design. (A percentage of egress lighting is now included in the shut- off requirement). ES 130.1(c) Carlsbad CBC20 19-0477 10/16/2019 END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. :• 2375 Camino Vida Roble, Suite B STR ATA : SKIN SCIENCES Carlsbad, CA 92011 November 18, 2019 To: City of Carlsbad From: Strata Skin Sciences, 2375 Camino Vida Roble Suite B Re: 2365 Camino Vida Roble Suite B, Office Improvement We request that the affected area of our tenant improvement be changed from 1,160 SF warehouse to office T.I to 546 SF warehouse to office T.I. What is shown on the first submittal as new storage area will be revised to show as warehouse area. This area will remain the same and only be affected by changing chain hung fluorescent light fixtures to chain hung LED fixtures. We currently lease three suites at this parcel and will only be re-seating one or two current employees to new R&D room. Sincerely, President & General Manager Carlsbad The Future of Dermatology strataskinsciences.com N A M ENGINEERS Consulting structural engineers 325 W. 3rd Ave., Suite 205 • Escondido, CA. 92025 Phone (760) 741-7306 • Fax (760) 738-8364 STRUCTURAL CALCULATIONS PROJECT NAME ; Strata Mechanical Roof Unit RECEIVED PROJECT NO.: 2019070 NOV 19 2019 CLIENT : Gary Garcia CITY OF CARLSBAD BUILDING DIVISION This signature is to be a wet I DESIGNED signature not a copy I APPROVED 4ri I BY: A. M. DATE SIGNED: 11 .11.3,120 11 I DATE : November, 2019 C IL CRW40fti9 &11,4"+ A M ENGINEERS Consulting Structural Engineers 325 W. 3rd Ave., Suite 205. Escondido, CA. 92025 Phone (760) 741-7306 Fax (760) 738-8364 CRITERIA (Roof Loading) Roofing 1.0 psf Mechanical Unit = 420 # Plywood 1.5 psf Sub-purlins 10 psf Purlins 2.0 psf Beams 2.0 psf Misc. 2.5 psf DL 10 psf LL= 20 psf Seismic: Seismic Design Category: D Wind: Exp. "C" Soils: Brg.=1500 psf Concrete: f'c=2500 psi for footings and slab f'c=3000 psi for structural slab Reinforc.: Fy=60000 psi for #5 and grater Fy=40000 psi for #4 and smaller Lumber: DFIL #1 for 2x rafters, 2x joists, beams and posts. DF/L #2 for 2x studs. 24F-V4 for simple span glue-laminated beams 24F-V8 for continuous glue-laminated beams Steel: ASTM A500, grade B for tubular sections ASTM A501, or ASTM A53, type E grade B for circular sections ASTM A572 grade 50 for all other sections. Masonry: f'm=lSOb psi Weld: Welding should conform to AWS DI-1. All welding shall be done by electric arc process using approved rods and performed by certified welders. All fabrication and welding shall be performed in the shop of an approved fabricator. The approved fabricator must submit a certificate of compliance in accordance with C.B.C. All field welding requires continuous special inspection and all shop welding requires periodic special inspection. Code: C.B.C. 2016 edition zoIqo7o SHEET NO. 2- OF CALCULATED BY DATE A M ENGINEERS Consulting _Structural _Engineers (760) 741-7306 /5 A7/1 h/k -20)c3/V -Alp L12- a1Z) v26 f rj <3rt),A i- 45 oll /et ciiq ic- I z pu,eo' c '4 1 /'xj u)qS - t6.0 -4i k1i4 =(D I1 ?"'" /S A6' F4 7( r-1t,4 = 2-27q 9q 3 jz ii LA1RL 42 JOB ig- A M ENGINEERS SHEET NO. OF Consulting _Structural _Engineers CALCULATED BY DATE (760) 741-7306 3Wf_ v. 35>€42 ::/$3?/A I S x 5/2. = 23o'4 4314mr 2-30 '1 'I U$ I/04t 1-46- &.,/1- F4c tZc(Qa7° 4 I I I I I I I I I I existing 44 purlin below... I I I I I I I I I I t picalJ 2x4 sub1 purhns I 21'o/c... i !' IIexisting url1be1 '/IIII! I I P ,U24' • ___ ...I............1...........4..............I I . I I If I I I, existing 4xl2 purlim belc I I I .0 I LA i'9'C4 s Ln typical 12x4 sub-purins I I I at 24'b/c... . I i i I IQj! I I existing xl2 purlin below... I I I I I I existing 64 purkn below... 0 .0 E .0 Q) cflAri 275 (k-f/tb V/DA Al A M ENGINEERS Consulting Structural Engineers (760) 741-7306 JOB -42D Iq 070 SHEET NO. OF CALCULATED BY DATE ------- —. I, w-4 V4 146- (liv /c — p, / (4o/) J 14 Id 3t4h1• . -. I, 7/0 ,&)t7 l,4811' 7A2 aX fAC4pJfP— .4c , gr-r,4 I C Q PLY o(J AT (ZY 'V 46 x I 44 4(777P) I voraill .J - - 1w - 4/ btiL. SAN DIEGO REGIONAL I OFFICEUSEONLY V. HAZARDOUS MATERIALS IPLANCHECK#Ct3 OLI7? (n1- RECORDID#_____ - QUESTIONNAIRE I BP DATE )Oi 7 i Busines)..ame 4yivh Bu s'ess Contaq 'kiv 5'c,ev-ei 'Shvtii.iel 60V Telephone # 160 Lo?- 3300 P roject Address 2-3S C C 1sI LIe 1 -."z State CA Zip Code I APN# I O& Mailing Address City State Zip Code I Plan File# Project Contact 4pp)i,cant E-mail I€2k Mey"i caJIrDrv1qflC Telephone # '114 3/'7_c,'- The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for proiects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards Flammable/Combustible Liquids 7. Pyrophoncs 11. Highly Toxic or Toxic Materials Flammable Solids 8. Unstable Reactives 12. Radioactives If the answer to any of the Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: YES NO (for new construction or remodeling projects) 0 5d Is your business listed on the reverse side of this form? (check all that apply). 0 [9 Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 09 Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? - Will your business store or handle carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1,320 gallons? Jifis Aboveground _Petroleum Storage Act). 4.0 5.0 6.0 7.0 I 8.0 CalARP Exempt Date Initials CaIARP Required Date Initials 0 CalARP Complete Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomtsdcountv.ca.gov (858) 586-2650). [*No stamp required if Qi Yes Q3 Yes Q4-Q6 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [Excludes garages & small outbuildings.] YES NO 0 I. Will the project disturb 160 square feet or more of existing building materials? 0 Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 0 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. 0 Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdaocd.orq/info/facts/oermits.odfl for typical equipment requiring an APCD permit. 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school boundary BrieJ describe l?u.siness activities: - I To' efiy describe proposed project: 1-'roLc4 -1 riedcd I4e.' I t4 tØko&'e1.e-4 , p4f"t ca-e I decla,(ikbenailv of perjury that to the best of my knowledge and belief tlle,.responses d herein re true and correct. 7 lJ I, fi4ey _ /0 /07 or Authorized Agent of Owner r Au orized Agent Date FOR OFJI'CAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:_____________________________________________________________________ BY: DATE: I / EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD APCD COUNTY-HMD APCD couNTy-HMD APCD A stamp in this box 9! exempts businesses from Completing or updating a Hazardous Materials 5usine55 Plan. other permitting requirements may Still apply. HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISION Check all that apply: AUTOMOTIVE Battery Manufacturing/Recycling Boat Yard Car Wash Dealership Maintenance/Painting Machine Shop Painting Radiator Shop Rental Yard Equipment Repair/Preventive Maintenance Spray Booth Transportation Services Wrecking/Recycling CHEMICAL HANDLING Agricultural supplier/distributor Chemical Manufacturer Chemical Supplier/Distributor Coatings/Adhesive Compressed Gas Supplier/Distributor Dry Cleaning Fiberglass/Resin Application Gas Station Industrial Laundry Laboratory Laboratory Supplier/Distributor Oil and Fuel Bulk Supply Pesticide Operator/Distributor CHEMICAL HANDLING Photographic Processing Pool Supplies/Maintenance Printing/Blue Printing Road Coatings Swimming Pool Toxic Gas Handler Toxic Gas Manufacturer METAL WORKING Anodizing Chemical Milling/Etching Finish-Coating/Painting Flame Spraying Foundry Machine Shop-Drilling/Lathes/Mills Metal Plating Metal Prepping/Chemical Coating Precious Metal Recovery Sand Blasting/Grinding Steel Fabricator Wrought Iron Manufacturing AEROSPACE Aerospace Industry Aircraft Maintenance Aircraft Manufacturing OTHERS AND MISCELLANEOUS Asphalt Plant Biotechnology/Research Chiropractic Office Co-Generation Plant Dental Clinic/Office Dialysis Center Emergency Generator Frozen Food Processing Facility Hazardous Waste Hauler Hospital/Convalescent Home Laboratory/Biological Lab Medical Clinic/Office Nitrous Oxide (NOr) Control System Pharmaceuticals Public Utility Refrigeration System Rock Quarry Ship Repair/Construction Telecommunications Cell Site Veterinary Clinic/Hospital Wood/Furniture Manufacturing/Refinishing ELECTRONICS Electronic Assembly/Sub-Assembly Electronic Components Manufacturing Printed Circuit Board Manufacturing NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMD) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses,, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District. CHEMICAL 47—Organic Gas Sterilizers 32— Acid Chemical Milling 33—Can & Coil Manufacturing 44— Evaporators, Dryers & Stills Processing Organic Materials 24— Dry Chemical Mixing & Detergent Spray Towers 35—Bulk Dry Chemicals Storage 55—Chrome Electroplating Tanks COATINGS & ORGANIC SOLVENTS 27— Coating & Painting 37— Plasma. Arc & Ceramic Deposition Spray Booths 38—Paint, Stain & Ink Mfg 27 —Printing 27— Polyester Resin/Fiberglass Operations METALS Metal Melting Devices Oil Quenching & Salt Baths 32— Hot Dip Galvanizing 39— Precious Metals Refining ORGANIC COMPOUND MARKETING (GASOLINE. [ETC) 25—Gasoline & Alcohol Bulk Plants & Terminals 25— Intermediate Refuelers 26— Gasoline & Alcohol Fuel Dispensing COMBUSTION 34— Piston Internal - Combustion Engines 13— Boilers & Heaters (1 million BTU/hr or larger) 14— Incinerators & Crematories 15— Burn Out Ovens 16— Core Ovens 20— Gas Turbines, and Turbine Test Cells & Stands 48— Landfill and/or Digester Gas Flares ROCK AND MINERAL 04— Hot Asphalt Batch Plants 05—Rock Drills Screening Operations Sand Rock & Aggregate Plants Concrete Batch, CTB, Concrete Mixers, Mixers & Silos Brick Manufacturing 51 - Aqueous Waste Neutralization Tire Buffers 17— Brake Debonders 23— Bulk Grain & Dry Chemical Transfer & Storage 45— Rubber Mixers 21 -Waste Disposal & Reclamation Units 36— Grinding Booths & Rooms 40— Asphalt Pavement Heaters 43—Ceramic Slip Casting 41 - Perlite Processing 40— Cooling Towers - Registration Only 91 - Fumigation Operations 56— WNTP (1 million gal/day or larger) & Pump Station FOOD 12— Fish Canneries 12— Smoke Houses 50— Coffee Roasters 35—Bulk Flour & Powered Sugar Storage SOLVENT USE 28— Vapor & Cold Degreasing 30— Solvent & Extract Driers 31 - Dry Cleaning ELECTRONICS OTHER 29— Automated Soldering 01 -Abrasive Blasting Equipment 42— Electronic Component Mfg 03— Asphalt Roofing Kettles & Tankers 46— Reverse Osmosis Membrane Mfg NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-9171 (08115) County of San Diego - DEH - Hazardous Materials Division I ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Date: i%1/19 • Business Name: Street Address: 2. S 4a,41'n ô /Zi PaJ/e .5'1-e ,9 Email Address: S'74a / - c o- PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: o Acid Cleaning o Food Processing o Metal Powders Forming o Assembly o Glass Manufacturing o Nutritional Supplement/Vitamin o Automotive Repair o Industrial Laundry Manufacturing O Battery Manufacturing o Ink Manufacturing o Painting/Finishing O Biofuel Manufacturing o Laboratory o Paint Manufacturing O Biotech Laboratory o Machining/Milling o Personal Care Products o Bulk Chemical Storage o Membrane manufacturing Manufacturing o Car Wash (i.e. water filter membranes) o Pesticide Manufacturing/ Packaging O Chemical Manufacturing o Metal Casting/Forming o Pharmaceutical Manufacturing o Chemical Purification o Metal Fabrication (including precursors) o Dental Offices o Metal Finishing 0 Porcelain Enameling Dental Schools Electroplating o Power Generation Dental Clinics Electroless Plating o Print Shop o Dry Cleaning Anodizing o Research and Development o Electrical Component Coating (i.e. phosphating) o Rubber Manufacturing Manufacturing Chemical Etching/Milling o Semiconductor Manufacturing o Fertilizer Manufacturing Printed Circuit Board a Soap/Detergent Manufacturing o Film/X-ray Processing Manufacturing 0 Waste Treatment/Storage New Business? Yes 0 No, SIC Code(s) if known: Date operation/will begin: 2-012- Tenant Improvement? Yes No[] If yes, briefly describe improvement: 416,6 1-4 ne ( 70 s24 Description of operations generating wastewater (discharged to sewer, hauled or evaporated):2ef jij.pjaf ,4f74,,,/7f Estimated volume of industrial wastewater to be discharged (gal/ day): L. List hazardous wastes generated (type/volume): Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes 0 Date: No 11 Page 1 of 2 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT VAM SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 -, SourceControl@encinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. Automobile Detailers Barber/Beauty Shops Business/Sales Offices Cleaning Services Carpet/Upholstery Childcare Facilities Churches Community Centers Consulting Services Contractors Counseling Services Educational Services (no auto repair/film developing) Financial Institutions/Services Fitness Centers Gas Stations (no carwash/auto repair) Grocery Stores (no film developing) Residential based Businesses Hotels/Motels (no laundry) Laundromats Libraries Medical Offices (no x-ray developing) Mortuaries Museums Nail Salons Nursing Homes Office Buildings (no process flow) Optical Services Pest Control Services (no pesticide repackaging for sale) Pet Boarding/Grooming Facilities Postal Services (no car wash/auto repair) Public Storage Facilities Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) CERTIFICATION STATEMENT I certify that the information above is true and correct to the best of my knowledge. Print Name: I4' DATE:____________ Facility Contact: Title: / & ENCINA WASTEWATER AUTHORITY 6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinaipa.com Page 2 of 2 (City of Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov PURPOSE This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures wilineed to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form •• Patio I •• Decks I + PME (w/o panel upgrade) + Pool If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. A Details on CAP ordinance requirements are available on the city's website. A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webøape and download the latest form. Application Information Project Name/Building Permit No.: BP No.: PropertyAddress/APN: j/,ç Ca"-'o /A.h. 51/, 4 l/10S627 Applicant Name/Co.: 5774 74 Applicant Address: Contact Phone: ,ç4LOU / eng , Contact Email: 574 ,4 c,,. Contact information of person completing this checklist (if different than above): Name: ,; g,q TContact Phone: 71g 3/? 67C Company name/address: ,_..( Contact Email: i 2f'7z Applicant Date: AD 7 B-50 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, çh Building Permit Valuation worksh!. Building Permit Valuation (BPV)from-works h $c 3, ¶ 57. 6 C) Construction Type Complete Section(s) Notes: A high-rise residential building is 4 or more stories, including a E1 Residential Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 0 New construction 2A, 3A, 1B, 2B, 3B 4A 0 Additions and alterations: BPV < $60,000 N/A N/A All residential additions and alterations BPV ~: $60,000 IA 4A 4A 1-2 family dwellings and townhouses with attached garages Electrical service panel upgrade only ' only *Multi-family dwellings only where interior finishes are removed BPV ~t $200,000 1A, 4A* 1B, 4A* and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 0 New construction 16, 2B, 3B, 4B and 5 Alterations: ( /L//,L( BPV ;t $200,000 or additions ~ 1,060-65 square feet BPV > $1,000,000 1B, 2B, 5 Building alterations of 2! 75% existing gross floor area ? 2,000 sq. ft. new roof addition 2B, 5 16 also applies if BPV 2:$200,000 CAP Ordinance Compliance Checklist Item Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary. 1. Energy Efficiency Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section. A. Residential addition or alteration? $60,000 building permit valuation. 0 N/A___________________________ See CMC section 18.30.190. 0 Exception: Home energy score a 7 (attach certification) Year Built Single-family Requirements Multi-family Requirements Before 1978 Select one: Duct sealing 0 Attic insulation 0 Cool roof 0 Attic insulation 1978 and later Select one: Lighting package 0 Water heating Package Between 19781 and 1991 Select one: Duct sealing 0 Attic insulation 0 Cool roof 1992 and later Select one: O Lighting package 0 Water heating package B. Nonresidential* new construction or alterations? $200,000 building permit valuation, or additions? 1,000 square feet. 0 N/A___________________________ Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CIVIC 18.21.155 and CALGreen Appendix A5, Division A5.2 - Energy Efficiency. A5.203.1.1 Choose one: 0.1 Outdoor lighting 0.2 Warehouse dock seal doors .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) 0 N/A_____________________________ .4 Daylight design PAFs 0 .5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: 0 .95 Energy budget 0 .90 Energy budget 0 N/A____________________________ A5.211.1" On-site renewable energy o N/A____________________________ A5.211.3** Green power (if offered by local utility provider, 50% minimum renewable sources) 0 N/A_____________________________ A5.212.1 Elevators and escalators 0 N/A___________________________ A5.213.1 0 Steel framing 0 N/A____________________ * Includes hotels/motels and high-rise residential buildings "For alterations 2! $1,000,000 BPV and affecting >75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CIVIC 18.30.130 instead. 2. Photovoltaic Systems E Residential new construction (for low-rise residential building permit applications submitted after 111120). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (2B below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(B) (high-rise residential) or 18.30.170(B) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional sheets if necessary) CFA #d.u. Calculated kWdc* Exception 0 0 0 0 Total System Size: kc kWdc = (CFAx.572) /1,000 + (1.15 x#d.u.) *Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. C] Nonresidential new construction or alterations 41,000,000 BPV and affecting V5% existing floor area, or addition that increases roof area by 22,000 square feet. Please refer to CIVIC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: / Gross Floor Area (GFA) Method GFA: Mink System Size: kWdc 0 If < 10,000s.f. Enter: 5 kWdc 0 If 2: 10,000s.f. calculate: 15 kWdc x (GFNI0,000) -- **Round building size factor to nearest tenth, and round system size to nearest whole number. 0 Time- Dependent Valuation Method Updated 8/15/2019 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:tm x.80= Mm. system size: kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A. El Residential and hotel/motel new construction Please refer to CIVIC sections 18.30.150 and 18.30.170 when completing this section. O For systems serving individual dwelling units choose one: O Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) El Heat pump water heater AND PV system .3 kWdc larger than required in CIVIC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) O Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher Solar water heating system that is either .60 solar savings fraction or-40 s.f. solar collectors Exception: O For systems serving multiple dwelling units, install a central water-heating system with all of the following: Gas or propane water heating system Recirculation system per CIVIC 18.30.150(B) (high-rise residential, hotel/motel) or CIVIC 18.30.170(B) (!ow- rise residential) Solar water heating system that is either: .20 solar savings fraction .15 solar savings fraction, plus drain water heat recovery Exception: B. El Nonresidential new construction Please refer to Carlsbad Ordinance CIVIC section 18.30.150 when completing this section. Water heating system derives at least 40% of its energy from one of the following (attach documentation): O Solar-thermal 0 Photovoltaics 0 Recovered energy O Water heating system is (choose one): O Heat pump water heater Electric resistance water heater(s) DSolar water heating system with .40 solar savings fraction DI Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A n Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. 0 One and two-family residential dwelling or townhouse with attached garage: 0 One EVSE Ready parking space required 0 Exception: 0 Multi-family residential: 0 Exception: Total Parking Spaces Proposed I EVSE Spaces Capable Ready Installed Total Calculations: Total EVSE spaces =.10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces - EVSE Installed (EVSE other may be 'Capable," Ready" or "Installed.') *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ~: $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), afterathns have a building permit valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to stthctural and mechanical, electrical, and/or plumbing systems are proposed. B. 0 Nonresidential new construction (includes hotels/motels) 0 Exception: Total Parking Spaces Proposed I EVSE Spaces Capable Ready Installed Total Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Spaces Number of required. EVSE Installed Spaces 0-9 1 10-25 . 2 26-50 4 2 51-75 6 3 76-100 9 5 101-150 12 6 151-200 17 9 0 201 and over 10 percent of total 50 percent of Required EV Spaces Updated 8/15/2019 1 ) 5 Updated 8/15/2019 6 City of Carlsbad Climate Action Plan Consistency Checklist 1 5. 0 Transportation Demand Management (TOM): Nonresidential ONLY I An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. Employee ADT Estimation for Various Commercial Uses Use first 1,000 1000 s.f.1 Office (al1)2 20 13 -- Restaurant 11 11 RtaIl3 8 4.5 4 35 4 -- 3 Industrial Manufactunng______ Warehousing .' 4 1 i Unless otherwise noted, rates estimated from ITE Trip Generation Manual, lOmEdition 2 For all office uses, use SANDAG rate of 20 ADT/1 ,000 sf to calculate employee ADT . Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses maybe subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf First l,000sf=8ADT 9,334 sf- 1,000 sf= 8,334 sf (8,334 sf/1,000 x 4.5) + 8 = 46 Employee ADT Acknowledgment: I adnowtedge that the plans submitted may be subject to the City of Cedsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TOM plan and understand that an approved TOM plan is condition of permit issuance. Applicant Signature: Date: Person other than Applicant lobe contacted for TOM compliance (if applicable): Name (Pñnted): -- Phone Number: Email Address: \ 4èityof 44aIla1I.14. Carlsbad Print Date: 03/02/2020 Permit No: PREV2020-0012 2375 Camino Vida Roble, B BLDG-Permit Revision• 2130502700 $ 0.00 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: Work Class: Commercial Permit Revi5 Status: Closed - Finaled Lot #: Applied: 01/29/2020 Reference #: Issued: 02/21/2020 Construction Type PermitFinal 03/02/2020 Close Out: Bathrooms: Inspector: LStor Orig. Plan Check #: CBC2019-0477 Final Plan Check #: Inspection: STRATA SKIN SCIENCE: CHANGE HVAC UNIT TYPE AND PLATFORM Owner: F R NATIONAL LIFE LLC 898 N Sepulveda Blvd, Ste 750 ELSEGUNDO,CA 90245 FEE AMOUNT BUILDING PLAN CHECK REVISION ADMIN FEE $35.00 MANUAL BLDG PLAN CHECK FEE $168.75 Total Fees: $ 203.75 Total Payments To Date: $ 203.75 Balance Due: $0.00 Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1760-602-8560 f I www.carlsbadca.gov Page 1 of 1 PLAN CHECK REVISION OR Development Services cr City of DEFERRED SUBMITTAL Building Division Carlsbad APPLICATION 1635 Faraday Avenue 760-602-2719 B-I 5 www.carlsbadca.gov Original Plan Check Number P,C,LO iq 001 Plan Revision Number PR I2o2o cxiL ProjectAddress (,'L oJiIe General Scope of Revision/Deferred Submittal: Q e CONTACT INFORMATION: Name tbti' Phone 1 / 4 /75-/&S Fax____________ Address City Zip Email Address Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1. Elements revised: ,Ø Plans Calculations . Soils D Energy LI Other 2. Describe revisions in detail 3. List page(s) where each revision is shown Chw 0P 4&.&1 . frw'AA 5Y, ()rO var. 612.eJ u (fs. /U ftt rthhr L-J/ ecL 4D 7) i1jk 'hi Does this revision, in any way, alter the exterior of the project? YeY LI No Does this revision add ANY new floor area(s)? El Yes No Does this revision affect any fire related issues? L1 Yes No Is this a Yes LI No €SSig 1635 X Date ("2 ' 2 Carlsbad, CA 92008Ph: 760-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov EsG11 A SAFEbui1f Company DATE: 2/13/2020 WLICANT JURIS. JURISDICTION: Carlsbad PLAN CHECK #.: 'CBC2O19-0477.rev SET: I revisited 2 PROJECT ADDRESS: 2365 Camino Vida Robles ste. B PROJECT NAME: Strata Revision The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. fl The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for. recheck. - LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person REMARKS: PREV2020-0012: Existing HVAC Screen" ( field ?verified. All sheets to be signed by the person in responsible charge of plans prior to permit issuance. By: Jason Pasiut Enclosures: EsGil 1/30/2020 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 19-0477.rev 2/13/2020 V. EsGil A SAFEbui1iCompany DATE: 2/7/2020 JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0477.rev SET: I PROJECT ADDRESS: 2365 Camino Vida Robles ste. B PROJECT NAME: Strata Revision O APPLICANT o JURIS. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. Li The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. Li The applicant's copy of the check list has been sent to: Li EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that. the plan check has been completed. Person contacted: Dale Meyers Telephone #: 714-317-5165 Date contacted: (by: ) Email: illegible Mail Telephone Fax In Person IZI REMARKS: PREV2020-047 (DID I By: Jason Pasiut 4 'Enclosures: EsGil 1/30/2020 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 19-0477.rev 2/7/2020 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK #.: CBC2019-0477.rev JURISDICTION: Carlsbad OCCUPANCY: B, S-i USE: Office, Storage ACTUAL AREA: 1,160sf TYPE OF CONSTRUCTION: V-A ALLOWABLE FLOOR AREA: complies SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 1/28/2020 DATE INITIAL PLAN REVIEW COMPLETED: 2/7/2020 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: unchanged OCCUPANT LOAD: 21 DATE PLANS RECEIVED BY ESGIL CORPORATION: 1/30/2020 PLAN REVIEWER: Jason Pasiut This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plani review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC20 19-0477.rev 2/7/2020 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. BUILDING AND LIFE SAFETY REQUIREMENTS All sheets of the plans and the first sheet of the calculations are required to be signed by the licensed architect or engineer responsible for the plan preparation. California State Law. 2. Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). Please provide updated NRCC-PRF documents that reflect the new HVAC equipment. END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: 0 Yes 0 No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. Carlsbad CBC20 19-0477.rev 2/7/2020 (DO NOT PAY— THIS IS NOT AN INVOICE) VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2019-0477.rev PREPARED BY: Jason Pasiut DATE: 2/7/2020 BUILDING ADDRESS: 2365 Camino Vida Robles ste. B BUILDING OCCUPANCY: B, S-i BUILDING PORTION AREA (Sq. FL) Valuation Multiplier Reg. Mod. VALUE ($) TI Revision hourly review Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code I #NIA 1997 UBC Building Permit Fee I Al : 1997 UBC Plan Check Fee 1!J Type of Review: r Complete Review r Structural Only I- Repetitive Fee FEI Repeats p. p. * Based on hourly rate I- Other Hourly 1.51H,s.@* Gil Fee $90001 p. I $135.00] Comments: Sheet 1 of 1 STRUCTURAL JOHN W. STARLIN, S.E. STRUCTURAL ENGINEERING 197 WOODLAND PARKWAY,. #410 SAN MARCOS, CA 92029 Phone (619) 840-7990 Email: engrjack@cox.net ROOF TOP MECHANICAL EQUIPMENT SUPPORT 2365 CAMINO VIDA ROBLE, SUITE B CARLSBAD, CALIFORNIA JANUARY - 2020 PR E/ a(4' 001 ?. JOHN W. STARLIN, S.E. STRUCTURAL ENGINEERING 197 WOODLAND PARKWAY #410 SAN MARCOS, CA 92069-3020 Phone (619) 840-7990 Email: engrjackcox.net Project: I Page: 2. 'of STRUCTURAL DESIGN SPECIFICATIONS BUILDING CODE -2017 California Building Code & ASCE 7-10 WOOD FRAMING - Design per 2012 NDS Specification for Wood Construction & Supplement Douglas Fir-Larch graded per WCLIB or WWPA grading rules as follows: Member Type Grade Fb (psi) Joists No 2 900 Beams (2x - 4x) No 1 1000 Beams(6x or larger B&S No 1 1350 Member Type Grade Fb (psi) Studs STUD 700 Posts (4x) No 1 1000 Posts (6x or larger) P&T No 1 1200 STEEL - Design per AISC Specification 360-10 Hot rolled steel complying with ASTM specifications as follows: Section Grade FylFu (ksi) Section Grade Fy/Fu (ksi) W - Wide Flange A992 50/65 Standard Pipe A53 Gr B 35/60 HSS - Tube A500 Gr B 46/58 Plates & Misc A36 36/58 WELDING - E70XX Electrodes with Fy = 70k5i unless noted otherwise in calculations CONCRETE - Design per CBC Chapter 19 and ACI 318-11 Specification for reinforced concrete Concrete fc = 2500psi at 28 days unless noted otherwise in calculations. Type II Cement CONCRETE MASONRY - Design per CBC Chapter 21 and ACI 530-11 Specification for Reinforced Masonry Medium weight solid grouted CMU with fm = 1500p5i unless noted otherwise in calculations Mortar - Type S with 4:1 mix ratio of cement to lime - fm 1500p5i Grout - 3:3:2 mix ratio of cement to sand to gravel - fg a 2000p5i STEEL REINFORCING - Bars complying with ASTM A615 (A706 for Welded Bars) as follows: Bar Size Grade Fy (ksi) Bar Size Grade Fy (ksi) #3,#4 A615Gr40 40 #5 and larger A615Gr60 60 STRUCTURAL COMPOSITE LUMBER - Manufactured by Trus Joist per ICC-ER ESR-1 387. Member Type Grade Fb (psi) Member Type Grade Fb (psi) Parallam (PSL) DF - 2.OE 2900 Timberstrand (LSL) DF - 1.7E 2600 Microlam (LVL) OF - 1.9E 2600 GLUE LAMINATED LUMBER - Douglas Fir-Larch Combination 24F-V4 unless noted otherwise in calculations MANUFACTURED WOOD I JOISTS - TJI Pro series by Trus Joist per ICC-ES ESR 1153 RETROFIT EPDXY - Simpson SET-XP designed per ICC-ESR ESR-2508 JOHN W. STARLIN, S.E. STRUCTURAL ENGINEERING 197 WOODLAND PARKWAY, #410 SAN MARCOS, CALIFORNAI 92069-3020 Phone (61 9j 840-7990 Email: engrjackcox.net Project: GRAVITY STRUCTURAL LOADS ROOF LOADS Load (psf) Dead Loads 12.0 Roofing 3.0 Plywood Decking 1.5 Joists 1.5 Purlins 2.5 Insulation 0.6 Sprinklers 1.5 Misc 1.4 Page: FLOOR LOADS Load (pat) Dead Loads 0.0 Live Load 20.0 Total Load 32.0 WALL LOADS Load (psf) Dead Loads Exterior Walls - Stucco 15.0 Interior Walls 10.0 Lateral Live Load - Code Minimum 5.0 Live Load - General Residential Total Load V IN Sr. °l 2475 *I$t E'p.. . •21 * LUCT 2365 Camino Vida Roble, Carlsbad, CA 92011, USA Latitude, Longitude: 33.1178139, -117.2695646 Cãñ9ino Vtdã Rot9 Custopharrn'lnc/j1 OP.TTelescopes I / /' / 0. The The Fields Church fI' North County ______9 LàiPalmàiDr .tj, Arts / I iU ---------------------- -- ------------- / OSHPD Alga Norte Comrnunit -Mapdaa©2O2% Date 1/27/2020, 8:32:41 AM Design Code Reference Document ASCE7-10 Risk Category 11 Site Class D - Stiff Soil Type Value Description Ss 1.062 MCER ground motion. (for 0.2 second period) S1 0.411 MCER ground motion. (for lOs period) SMS 1.142 Site-modified spectral acceleration value SMI 0.653 Site-modified spectral acceleration value SOS 0.761 Numeric seismic design value at 0.2 second SA Sol 0.435 Numeric seismic design value at 1.0 second SA Type Value Description SOC D Seismic design category Fa 1.075 Site amplification factor at 0.2 second Fv 1.589 Site amplification factor at 1.0 second PGA 0.411 MCEG peak ground acceleration FP" 1.089 Site amplification factor at PGA PGAM 0.448 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.062 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.093 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.5 Factored deterministic acceleration value. (0.2 second) 51 RT 0.411 Probabilistic risk-targeted ground motion. (1.0 second) Si UH 0.4 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. SID 0.6 Factored deterministic acceleration value. (1.0 second) PGAd 0.504 Factored deterministic acceleration value. (Peak Ground Acceleration) CRS 0.971 Mapped value of the risk coefficient at short periods CR1 1.026 Mapped value of the risk coefficient at a period of 1 s DISCLAIMER While the information presented on this website is believed to be correct, SEAOC IOSI-$PD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC I OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website. JOHN W. STARLIN, S.E. STRUCTURAL ENGINEERING 197 WOODLAND PARKWAY, #410 SAN MARCOS, CA 92069-3020 Phone (619) 840-7990 Email: engrjackcox.net Project: Page of I 0 r T au f' 0,3/*/,o'k+oo /1 rp Iir. I.C- .7c.i i° "4e çoi : o,4' (/+(zi_) 1 - . -- ---i- - -. •1 . . 1 A 5 U 'iii; C 4of!sf,t,.Jef. -1 1TYP I 14 -C. - -.,- .- ... - '.- ()2 FEATURES- '_38 -eftd24" Tall Available 18 Gauge Construction 1X4 Wood Nailer Shipped Knocked Down With All Hardware Gasket Included Bed Rail Style Corners NOTE: OUTSIDE DUCT DIMENSION SHOULD BE 1/2" John W. Starlin, S.E. STRUCTURAL ENGINEERING 1741 Judith Place Escondido, CA 92026 - 619.840.7990 Cell E-mail ENGRJACK@COX.NET Job: CAMINO VIDA ROBLE Sheet No: SX1 Of: Calculated By. Date: Checked By: Date: Scale: NTS z(E) 2x6 JOIST z(E) 2x6 JOIST 606 PURLIN ROOF TOP MEXH. EQUIPMENT 2x6 JOIST ROOF TOP EQUIPMENT SUPPORT (SXJ NM ) Date Plotted: 1/27/2020 10:44 AM Plotted By. JACK STARLIN File:G:\DALE MEYERS\SAN MARCOS ROOF TOP MECH SUPPORT\DWG\CNS\SX 1.DWG It John W. Starlin, S.E. STRUCTURAL ENGINEERING 1741 Judith Place Escondido, CA 92026 619.84a 79go Cell E-mail ENGRJA CK@COX NET Job: CAMINO VIDA ROBLE Sheet No: SX2 Of: Calculated By: Dote:___________________ Checked By: Date:_____________________ Scale: NTS Date Plotted: 1/27/2020 10:43 AM Plotted By. JACK STARLIN File: G:\DALE MEYERS\SAN MARCOS ROOF TOP MECH SUPPORT\DWG\CNS\SX 1.DWG