Loading...
HomeMy WebLinkAbout2385 MARRON RD; ; 85-552; Permita O H t C z O U W O J O LU W z 3 O z z O P G Q U W 0 ❑ I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with I Section 7000) of Division 3 of the Business I and Professions Code, and my license is in full force and effect. Llc. No Class I hereby affirm that I am exempt from the Contrac- tor's License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which re- quires a permit to construct, alter, improve, demolish, or I repair any structure, prior to its issuance also requires the ap- plicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractors License Law (Chapter 9 commencing with Section 7000 of Division 3 of the Business and Professions Code) or that is ex- empt therefrom and the basis for the alleged exemption. Any violation of Section 7031,5 by an applicant for a permit sub- jects the applicant to a civil penalty of not more than five hun- dred dollars ($500). I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the struc- ture is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intend- ed or offered for sale. If, however, the building or improve- ment is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or im- prove for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with It contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or im- proves thereon, and who contracts for each projects with a coniractor(s) license pursuant to the Contractor's License Law). ❑ As a homeowner I am improving my home, and the follow- ing conditions exist: 1. The work is being performed prior to sale. 2. 1 have lived in my home for twelve months prior to completion of this work. 3. 1 have not claimed this exemption during the last three years. ❑ I am exempt under Sec. , B t for this reason I ❑ I hereby affirm that have a certificate c.Nsenl to self -insure. or a Certificate of Workers' Comp nsati.n In- surance. or a certified copy thereof (Sec. 3800, abor Code) POLICY NO. z O COMPANY Q ❑ Copy is filed with the city ea z ❑ Certified copy Is hereby furnished W a 2 UCERTIFICATE OF EXEMPTION FROM H WORKERS' COMPENSATION INSURANCE Q (This section need not be completed if the permit W Is for one hundred dollars ($100) or less) Y ❑ 1 certify that in the performance of the work for which 3 Q this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compen- sation Laws of California. NOTICE TO APPLICANT: If, after making this Certificate of Exemption, you should become subject to the Workers' y.Compensation provisions of the Labor Code, you must iwufrwith comply with such provisions or this permit shall be deemed revoked. ❑ I hereby affirm that there is a construction lending Q agency for the performance ofthe work for which this per- W C mit is issued (Sec. 3097, Civil Code) z W Lender's Name J Lender's Address _ USE BAIL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. g, CARLSBAD BUILDING DEPARTMENT APP�I�ATI®N &PERMIT A Carlsbad, California 92008-1989 (619) 438-5525 F/P FLR ELEV. a L Y❑ N❑ ,ILL ,®" sls adA .n CENSUS TRACT GPLANDUSE PARKING SPACE RES UNITS GRADING PERMIT ISSUED REDEVELOPMENT AREA Y❑ IN El Y❑ N❑ OTY. PLUMBING PERMIT - ISSUE EACH FIXTURE TRAP EACH BUILDING SEWER EACH WATER HEATER AND/OR VENT EACH GAS SYSTEM I TO 4 OUTLETS EACH GAS SYSTEM 5 OR MORE EACH INSTAL., ALTER, REPAIR WATER PIPE EACH VACUUM BREAKER WATER SOFTNER EACH ROOF DRAIN (INSIDE) _--- . —. .___-_ TOTAL PLUMBING OTY. ELECTRICAL PERMIT - ISSUE NEW CONST EA AMP/SWT BKR I PH 3 PH EXIST BLDG EA AMP/SWT/BKR 1 PH 3 PH REM0DEL'ALTER PER CIRCU TEMP POLE 200 AMPS OVER 200 AMPS TEMP OCCUPAN 30 OAYSI TOTAL ELECTRICAL �• OTY. MECHANICAL PERMIT - ISSUE ►�. INSTALL FURN. DUCTS UP TO 100,000 BTU OVER 100,000 BTU BOILER/COMPRESSOR UP TO 3 HP BOILER/COMPRESSOR 3-15 HP METAL FIREPLACE VENT FAN SINGLE DUCT MECHEXHAUST -HOOD/DUCTS RELOCATION OF EA FURNACEI ER TOTAL MECU.WICAL SOLAR - ISSU TAN CK FEE L UATION ZONE PLAN I.D. # 1 PERMIT NUMBER LL O a E O (— BUILDING SO. FOOTAGE O 0 NU OCC GP EDU I W,5 / t,! 41Et 6d6Cr STORIES TYPE OCC LOAD FIRE SPR CONST Y ❑ N ❑ Not Valid Unless Machine Certified 3 re SUMMARY/ACCOUNT NUMBER BUILDING PERMIT 001-810-00-00-8226 SIGN PERMIT 001-810-00-00-8221 PLAN CHECK 001-810-00-00-8806 TOTAL PLUMBING 001-810-00-00-8222 ELECTRICAL 001-810 00-00-8223 MECHANICAL 001-810-00-00-8224 MOBILEHOME 001-810-00-00-8225 MOBILEHOME PARK INSP SOLAR 001-810-00-00-8226_ _ STRONG MOTION 880-519-92-33 ---- —_---. - — _— -- FIRE SPRINKLERS 001-810 00 00-8227 _ PUBLIC FACILITIES FEE 332-810 00-00-8930 SCHOOL FEE - DISTRICT Carlsbad Encinitas San Dieguito San Marcos LICENSE TAX 001-810-00-00-8162 e+✓ OFF 880-519-92-57 CREDIT DEPOSIT TOTAL- SOLAR TOTAL FEES PAYABLE APPROVED#Y DATft ?I Lim TYPE I DATE INSPECTOR BUILDING FOUNDATION REINFORCED STEEL ► MASONRY G_UNITE OR GROUT ! FRAME 0 FLOOR 0 CEIQING -SHEATHING ❑ ROOF 0 SH All FRAME I EXTERIOR LATH ! INSULATION i INTERIOR LATH & DRYWALL i PLUMBING ❑ SEWER- AND BL/CO ❑ PIL/CO UNDERGROUND ❑ WASTE ❑ WATER TOP OUT ❑ WASTE ATER TUB AND SHOWER PAN GAS TEST a 0 WATER HEATER ❑ SOLAR W TER I ELECTRICAL I ❑ ELECTRIC UNDERGROUND El, ROUGH ELECTRIC ! ❑ ELECTRIC SERVICE ❑ TEMPORARY ❑ BONDING ❑ POOL I MECHANICAL t ❑ DUCT & PLEM., ❑ REF. PIPING HEAT — AIR COND. SYSTEMS i VENTILATING SYSTEMS I CALL FOR FINAL INSPECTION WHEN ALL APPROPH17 ITEMS ABOVE HAVE BEEN APPROVED. FINAL PLUMBING ELECTRICAL MECHANICAL I GAS t BUILDING SPECIAL CONDITIONS , FIELD INSPECTION RECORD h REQUIRED SPECIAL INSPECTIONS INSPECTOR'S NOTES- INSPECTION REQ. IF CHECKED INSPECTOR'S APPROVAL DATE SOILS COMPLIANCE PRIOR TO, FOUNDATION INSP `~ STRUCTURAL CONCRETE OVER 2000 PSI,. PRESTRESSED ' CONCRETE PO$T,TENSIONED CONCRETE FIELDMELDING HIGH STRENGTH BOLTS SPECIAL fVt,ASONRI , PILES CAISSONS a � r ' / r 14 ' City —of Carlsbad ' 1 MISCELLANEOUS 1200 ELM, CARLSBAD, CA 92008 • TEL. (619) 438-5525 RECEIPT Job Address... -^a �*.:�"""-••" i c_r�;;f'; ': ,J':--�xi-=r-; MISCELLANEOUS FEE RECEIPT _ I t f ." _ � ". �. Owner ❑ * PLAN CHECK FEE 01.00-00.88,0.E j ❑ VALUATION Mailing �,;+++�'` Address w,espyCj /}�dsJ City f }`��s::;d±A�'!±r"� �,.«✓«."�=%trA'J _ Zlpq ✓'��'+�G+ti' Tel. 7 '%i r1G��+'Tt'.���.r�'+�%�"i ❑ DEMOLITION Contractor / ❑ HOUSE MOVING ❑ PARKS AND RECREATION FEE Addressp>,r�y .p ❑ FEE City r ✓fl Zip Tel Ge-91043-on PUBLIC FACILITIES ❑ SCHOOL.FEE - DISTRICT city State Lic. S. Classif. Lic. No. ❑ Carlsbad COMPLETE FOR PLAN CHECK ONLY ❑ Encinitas ❑ San Diego LEGAL DESCRIPTION ❑ San Marcos ❑ CERTIFICATE OF OCCUPANCY ASSESSORS PARCEL NO. I " t`7 - -j )Z IPTION OF WORK /'.SPY 'd`fe5i %`�" %f�"'� `//4, _- `t PLAN ID'NO. / LJ DESIGNER ADDRESS i'aI /� ' // ^;/✓ _ ❑ PHONE / TOTAL FEE $C CONTACT PERSON. �1X11 Z' •f �� y WARNING: PLAN CHECK FEES, WHERE NO ACTION IS TAKEN BY THE APPLICANT IN 180 DAYS AND NO BUILDING PERMIT IS ISSUED, ARE FORFEITED TO THE CITY. Sr/ '"lid r. ��r✓ r� �✓wS. ` Signature of ApplicanU,! ✓? .. lr�f. t 3te White — Applicant Yellow — File Pink — (1) Finance (2) Data Process Gold — Assessor 1� f PLAN CHECK NUMBER25-SSAC PLANNING: TYPE OF STRUCTURE SCHOOL FEES: SAN DIEGUITO NUMBER OF UNITS CARLSBAD 1 < BUILDING HEIGHT 1 FENCES/WALLS' -- TWO CAR GARAGE E-74 m b o CC�",MENTS: o Q REDEVELOPMENT APPROVAL REQUIRED:Lw c LANDSCAPE PLAN COMMENTS: :ONE: ENCINITAS SAN MARCOS REQUIRED SETBACKS FRONT SIDE REAR rP:VI"C-%s,,Z"JTAL REQUIRED: ADOITIO11AL CO3jV4ENTS: ktercbc OK TO ISSUE:Nt' DATE: 19SOK TO FINAL: DATE: * r.+.w#r**^..tir.?:... �.�..r wN. ..... ..r..ti: r.:.��.�.��.^..��.�.•..^:..^7Y##**##s;-itttt:Yt't*1t********.*lt*#*##tom ENGINEERING LEGAL DESCRIPTION VERIFIED? A.P.N. CHECKED? P.F.F. PARK IN LIEU R.O.W: IMPROVEMENTS: E.D.U: SEWER: LATERAL: DRIVEWAY: W GRADING PERMIT: ... yd DRAINAGE: EASEMENTS: ADDITIONAL COMMENTS: OK TO ISSUE: * ENGINEERING INSPECTION REQUIRED: PUBLIC WORKS INSPECTOR: DATE:,=%��� FINAL OK: DATE: - I * IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE ALL INSPECTIONS (DRIVEWAYS, CURB CUT, DRAINAGE, ETC.) -1206 ELM AVENUE CARLSBAD, CA 92008-1989 TELEPHONE (619) 438-5523 Citp of Carlobab FIRE DEPARTMENT PLAN CHECK REPORT PAGE 1 OF I APPROVED' DISAPPROVED PLAN CHECK# 6- PROJECT E•!WeNA V620,cl ADDRESS 1,1rA.T A-41..1ar)AI ARCHITECT 'V-lrlJkr-y` odrunc. ADDRESS 101Y i tSSsA«»+ z PHONEvs'- OWNER eW 01_Mr'14A ADDRESS PHONE -'fit 0 2 0 OCCUPANCY CONST. 1- N TOTAL SO. FT. STORIES �^0s ❑ SPRINKLERED KTENANT IMP. APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: PLANS, SPECIFICATIONS, AND PERMITS 1. Provide one copy of: floor plan(s); site plan; sheets 2. Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. 3. Provide specifications for the following: A' wJ? AORIlfNapmet4ry io r I. ArSles 4. Permits are required for the installation of all fire protection systems (sprinklers, stand pipes, dry chemical, halon, COz, alarms, hydrants). Plan must be approved by the fire department prior to installation. 5. The business owner shall complete a building information letter and return it to the fire department. FIRE PROTECTION SYSTEMS AND EQUIPMENT 6. The following fire protection systems are required: ❑ Automatic fire sprinklers -(Design Criteria: ) ❑ Dry Chemical, Halon, CO2 (Location: ) ❑ Stand Pipes (Type: ) ❑ Fire Alarm (Type/Location: ) 7. Fire Extinguisher Requirements: ( One 2A rated ABC extinguisher for each A000 sq. ft. or portion therbof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. ❑ An extinguisher with a minimum rating of to be located: ❑ Other: 8. Additional fire hydrant(s) shall be provided EXITS X 9. Exit doors shall be'openable from the inside without the use of a key or any special knowledge or effort. A sign stating, " This door to remain unlocked during business hours" sha,)1 be placed above the main exit and doors €u(..,a, u-r,L,Z/rf AP 4-1 1rA7 iV Z)�%_11�r3/%✓i/ fi Ej 11. EXIT signs (6" x 3/4" letters) shall be placed over all required exists and directional signs located as necessary to clearly indicate the location of exit doors. GENERAL —M,12. Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code. 13. Building(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing is to be done, comply with Uniform Fire Code, Article 81. 14. Additional Requirements. u yl� 110Z I 15. Comply with regulations'p ttached shee/eft(s). Plan Examiner r u Report mailed to architect Met with Date t f� Attach to Plans 1, ," ESGIL CORPORATION 9320 CI3ESAYEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (610) 560-1468 DATE: JURISDICTION: CITY �f C1J.2lQ PLAN CHECK NO: Fe.5 - 5:1552 PROJECT ADDRESS: 'Z595 N%Ad2 PROJECT NAME: o5t7, L'AGr �i.UEM/�S []APPLICANT In JURISDICTION PLAN CHECKER FILE COPY UPS DESIGNER D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being hel-d at Esgil Corp. until corrected plans are submitted for recheck. o The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: o Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has ® been completed. Person .contacted: G,4, Date contacted: 9��7%� Telephone # REMARKS-.. BY: �• ENCL: ES IL CORPO ATION �I r Q APPLICANT COPY ("CITY COPY Q PLAN CHECKER COPY UP of Cad5bab 9/ 7f S5 JURISDICTION: �J DATE PROJECT ADDRESS: 23 SJ�-Lt.�t7NJ' TO: PLAN CORRECTION SHEET Plan 6heck- No.. Pats, plans received by jurisdiction Pate plans receive& by plan checker���O 9J� Date initial .plan check completed. FhRE140R0: PLEASE READ Plan check is •limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code_, Uniform Mechanical Code, National Electrical Code and state lawsregulatingenergy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department,. Engineering Department or�other departments. The items circled below need clarification, modification or change. All circled items have tc be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec._303 (c), r979 Uniform Building Code, the approval of the plans does not permit th& violation -of any state, county or city law. A. ELM OPlease make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been ,returned to you by the jurisdict-ion, to: .EsG/L C©l2A. 932o CN��APEgtC� .D.E'. OTo facilitate rechecking, please identify, -- next to each circled item, the sheet of the plans upon which each correction on this sheet has- been made and return this check sheet with the revised plans. 1 CITY OF CARLSBAD PLAN CHECK NO. 85-552 23-85 MARON SEPTEMBER 18, 1985 3. Plans are incomplete and cannot be fully checked at this time. Checking will resume when plans signed by the responsible architect are submitted. The following are obvious deficiencies at this time. 4. Submit complete electri.cal, plumbing and mechanical plans, details and calculations. 5. Provide structural details and calculations for existing bearing walls, and shear walls to be removed. Provide, structural and architectural plans of the existing building, 6. Provide architectural plans which: a. are dimensioned b. show existing use of all rooms c., identify type of construction, occupant loads and occupancy classification d-. show details, of new partition construction including attachment at top and bottom to ceiling (or roof framing) and to floor e. show existing, and new, seating in -auditoriums and exit locations f. show that -existing toilet facilities comply with handicap access requirements g: contain appropriate details of required fire resistive .construction h. contain plan of mezzanine level -and exits therefrom. 7. Provide a realistic evaluation of work to be performed. If you have any questions, please contact Jim Gilshian or Gene Meier of Esgil Corporation at (619) 560-1468. Thank you. z Date: 9 i� 85 Jurisdiction ,.Prepared bys q Bldg. Dept. VALUATION AND PLAN CHECK _FEE p Esgil PLAN -CHECK NO. BUILDING ADDRESS 2 3 8 /�/A2caa1 APPLICANT/CONTACT PHONE No. 213 682 /5¢7 BUILDING OCCUPANCY A-' e./. DESIGNER PHONE Z13 (,'82 /5¢7 TYPE -OF CONSTRUCTION "CONTRACTOR PHONE 6/9 94,3 0937 BUILDING PORTION• 'BUILDING AREA 'VALUATION- MULTIPLIER VALUE fCAatJ 7 -Air Conditioninz Commercial @ Residential Res: or Comm. Fire Snrinklers @ Total Value 40, U--U'' Fee Adj-usted To Reflect ❑ Ene.rgy Regulations (Fee x 1.1) - ❑ Handicapped Regulations (Fee x 1.065) Building Permit Fee. $_ 01 Plan Check Fee, $ $ 154, :10 COMMENTS• J��lL G�AjtDAJ 4olz-i- Oe hJ42EA, 6- o b 2EFL ECT '��L/-Si lC 8/4/82 ESGIL CORPORATION. _ 9320 CHESAYEAKE DR., SUITE 208 SAN DIEGO,, CA 92I23 (6 19) 560- 1468 DATE: - / p85 JURISDICTION: 4., xe _-,a p PLAN CHECK NO: Q APPLICANT [] JURISDICTION PLAN CHECKER ❑ FILE COPY []UPS ❑ DES_IGNER PROJECT ADDRESS: 2385 MAR.OrJ PROJECT NAME: ►J€"A The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when deficien- cies identified oAJ TN.- ,4TTti?GNEG Wfe7- t's) are .resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at ,Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the ❑ jurisdiction to return to -the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # REMARKS: BY: ENCL: .ESGIL CORP OR TION CITY OF CARLSBAD PLAN CHECK NO. CB 85-552 IV PLAZA CINEMA The following corrections are assumed to have been satis- factorily resolved by thew -,gilding Aficial : 1. Handicap seat' for wheeOd hair and for semi-ambulent patrons, the' location number, is assumed to be acceptable as shown o the -plans. Orig. Corr. #2(e). 2. A., Panic hardware i required on -all exit doors from the audit- iums. (Note that where such exit doors ar also required to be 20 minute assemblies, latching mechanism is required which prec des r iance upon the exception to 3318(a). rig Cor #5. B. Since th width of t orridor (lobby) is not 30ft. ( structed by k bar counter) corridor openin protection i e ired per U.B-.C. 3305(h). Orig. orr. #4. The na bar wooea not be a use n rmally allowed n corridor (lobby), howe r such use is ication of existing and s b gener permitted in theatre lobbi 3. The acceptability o let facilities should be made by the Building -Official based upon the "hardship" provisions contained in Title 24. 4. Plans are required to be signed by the licensed engineer or architect. 5. The building official has determined that the exist- ing plywood shear wall which will be punctured by an 8' wide opening is acceptable without additional reinforcement. City of Carlsbad Plan Check No. 85-552 November 20,.1985 6. Note that no exterior work is included in this in- dication of compliance by Esgil.Corporation. A copy of the October 26, 1985 correction sheet is en- closed for reference. In the event that the above items have not been resolved and additional Esgil services are necessary, please contact Gene Meier at (619)560-1468. ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: A 0✓EMB--F? 20 / I F5 JURISDICTION: �A,2G5P3A� PLAN CHECK NO: PROJECT ADDRESS: Z385 MAR-Ory PROJECT NAME: PLAZA C 1 t.JE,"A []APPLICANT ;;,j, JURISDICTION []PLAN CHECKER ❑ FILE COPY ❑ UPS ❑ DESIGNER The plans transmitted herewith have been corrected where ❑ necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply im with the jurisdiction's building codes when deficien- cies identified oAJ_TNa 4,7-Ac,y.-a .a, eer ,Is) are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies ❑ identified on the enclosed check list and should be corrected and res-ubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's ❑ copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. ❑ The applicant's copy of the to the check list is enclosed for the contact jurisdiction to return applicant person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant conta-ct person that plan check has been completed. Esgil staff did advise applicant that the plan check has ❑ been completed. Person contacted: Date contacted: Telephone # REMARKS: BY • ESGIL CO e "T I ON ENCL: f ' a R 1 i . CITY OF CARLSBAD PLAN CHECK NO. CB 85-552 IV PLAZA CINEMA The following corrections are assumed to.have been satis- factorily resolved by the Building Official: 1. Handicap seating for wheelchair and for semi-ambulent patrons, their location and number, is assumed to be acceptable as shown on the plans. Orig. Corr. #2(e). 2. A., Panic hardware is required on all exit doors from the auditoriums. (Note that where such exit doors are also required to be 2.0 minute assemblies, a latching mechanism is required which precludes reliance upon the exception to 3318(a). Orig Corr. #5. B. Since the width of the corridor (lobby) is not 30ft. (obstructed by snack bar counter) corridor opening protection is required per U.B:-C. 3305(h). Orig. Corr. #4. The snack bar would not be a use normally allowed in an exit corridor (lobby), however such use is a modification of existing and has been generally permitted in theatre lobbies. 3. The acceptability of toilet facilities should be made by the Building Official based upon the "hardship" provisions contained in Title 24. 4. Plans are required to be signed by the licensed engineer or architect. 5. The building official has determined that the exist- ing plywood shear wall which will be punctured by an 8' wide opening is acceptable without additional reinforcement. City of Carlsbad Plan Check No. 85-552 November 20, 1985 6. Note that no exterior work is included in this in- .dication of -compliance by Esgil Corporation. A copy of the October 26, 1985 correction sheet is en- closed for reference. In the event that the above items have not been resolved and additional Esgil services are necessary, please contact Gene Meier at (6.19)560-1468. CITY OF CARLSBAD PLAN' CHECK NO: CB 85-552 IV PLAZA CIN The following corrections are assumed to have been satis- factorily resolved by the Building Official: is �? . andica p seating for wheel chair and for semi-ambulent �� P g . �O patrons, their location and number, is assumed to be cceptable as shown on the plans. Orig. Corr. We). 2. Panic hardware is required on all exit doors from the auditoriums. (Note that where such exit doors are also required to be 20 minute Q Q.�� assemblies, a latching mechanism is required aIr 1� D which precludes reliance upon the exception to 0 � y 3318(a). Orig Corr. #5. B. Since the width of the corridor (lobby) is not 4 30ft. (obstructed by snack bar counter) corridor opening protection is required per U.B:C. 3305(h). Orig. Corr. #4. The snack bar would not be a use normally allowed in an exit corridor (lobby), however such use is a modification of existing and has been generally permitted in theatre lobbies. The acceptability of toilet facilities should be made by the Building Official based upon the "hardship" • provisions contained:Ta124 4. P1 s-are required to be signed by the license engineer or architect. 5 The building official has determined that the exist- ing plywood shear wall which will be punctured by A. 8' wide opening is acceptable without addit_i ozZa_ V (reinforcement. 1 k DEVELOPMENTAL SERVICES - BUILDING DEPARTMENT C itp of C arrobaa 1200 ELM AVENUE CARLSBAD, CALIFORNIA 92008-1989 (619) 436-5525 Dear Property Owner: - An application for a building permit has been submitted.in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by the property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City of Carlsbad., They are.also required by law to, put their -license number on all permits for which they apply. If you plan to-do your own work, with the exception of various trades that.you plan to subcontract,. you should be aware of the following information for your benefit'and pro- tection. If you employ or -otherwise engage any, persons other than your immediate family, and the work (including material and other costs) is $200 or more for the entire project, and such persons are not iicensed.as contractors or subcontractors, then'you may be an employer. If you are an employer, you must register with the state and federal government as an employer and you are subject to several, obligations including state and federal income withholding, federal social security taxes, workers' compensation insurance, disability insurance costs, and unemployment contributions. There May be financial risks for you if you do not carry out these obligations -and -these is s are espec ally ser ous -57-5- with resoect to wor ers compensation insurance. For specific information about your.obligati.ons under federal law, contact the Internal Revenue Service (and, if you .wish, the U.S. Small Business Administrati-on). For more specific information about your obligations under state law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform -their work"personally or through their own employees, without a licensed contractor or subcontractor, only,under limited conditions. A frequent practice of unlicensed persons professing to be contractors is ;,o secure an "owner -builder" building permit, erroneously implying that the property ovwer is providing his -or her own labor and material personal-ly. Building permits are not required to be signed by property owners unless they are performi-ng their own work personally. Informa- tion about licensed contractors, maybe obtained by contacting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA 95814. PLEASE'COMPLETE AND RETURN THE ENCLOSED OWNER -BUILDER VERIFICATION FORM SO THAT WE CAN CONFIRM THAT YOU ARE AWARE OF THESE MATTERS. THE BUILDING PERMIT WILL NOT BE ISSUED UNTIL THE VERIFICATION -IS RETURNED. Very truly yours, Buil-di-ng Department City of Carlsbad ATTENTION PROPERTY OWNER: An "owner -builder" buil-ding permit has been applied for in your name and bearing your signature. Plea -se complete and return this information in the envelope provided at your earliest opportunity to avoid unnecessary delay in processing and,issuing your building permit. No building permit will be issued until this verification is received. 1. I personally,plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) 2. 1 (have/have not) _ i(/�fi signed th appli-cation for a 'building permit: 3. 1 have contracted with the following person (firm) to provide the proposed construction.. Name Phone Address Contractors License No. City 4. I plan to provide portions of the work, but 'I have hired the following person to coordinate, supervise and provide the major work. Name v22 , i��1Z _ � / rvf> Phone e,/ i,q — 2 41'3 --e> 3 3 7 Address • 6g )Fz1V . ,si12_- Contractors License No. City f G?% 2 9 F 5. 1 will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work Signed: Property Owner 'So�'�-� g Social Security Number �/, �-- 3 Z —L Date: EACH SUBCONTRACTOR WILL BE INSTRUCTED TO OBTAIN A CITY OF CARLSBAD BUSINESS LICENSE AND FURNISH.A CERTIFICATE OF WORKMAN'S COMPENSATION TO THE CITY OF CARLSBAD. Initials v r ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: OC.'� O 1��(Z, �_ZCo lq-% Gj .[] APPLICANT E]JURISDICTION JURISDICTION: CAQLS &gyp f-1 PLAN CHECKER FILE COPY PLAN CHECK NO: � r.>- - __ 11;c UPS DESIGNER PROJECT ADDRESS: 2 3 CS 5 N1 A2 _o tJ _ PROJECT NAME: 50, CALtr- C►wEMA-S LAZ-4- EMh D The plans transmitted herewith have been corrected where necessary and substantially comply -with the, jurisdiction's building codes. The plans transmitted herewith, will .substantially comply with the _jurisdiction's building codes when minor defici.en- cies identified - are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies [� identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's ® copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. ® The applicant's copy of the check list has been sent to: `a�4 _,t7iSs o.c� Sr �.. �ASgQEc CAS 9105 o o Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that,,the„nL�ch, ck has been completed.' Person contacted: !1 Date. contacted: ��� �� �� Telephone # 2/3-�82-i5d7 REMARKS: BY: ENCL: SGIL CORPOR LON n r } w CITY OF CARLSBAD PLAN CHECK NO. CB8.5-522 III PLAZA CINEMA OCTOBER 30, 1985 Since original submittal consisted of incomplete plans, these corrections reflect plan ch-eck results of what is considered an initial plan. check. 1. Provide a completely dimensioned floor plan of the existing building and indicate the building area on the plans. Provide justification for exceeding the allowable area set forth in -Table 5C. (See U.B.C. Section 502, work to be done represents a change of occupancy from A-3 to A2.1) 2.- Auditorium #4, A2.1 occupancy (change from A-3) a)-3 exits are required, (only 2 exits have been provided) side exits, to accomodate 1/3 ;.he occupant Load are required on each -side. U.B.C._ Sections 33-03(a); 3303(c); 3317(b), b) Provide a seating arrangement, show number of seats per row, dimension aisle and cross ai-sle widths. U.B.C: Sections 3315(d).; 3315(b) 3; 3315(e). c) Show ramp slope of main aisle, see U.B.C. Section 3307(c) Max. slope 1:5. d) Ramps leading from upper end of aisles to the main exit (to lobby) may have a sl-ope not exceeding 1:12. U.B.C. Section 3307(c). Provide handrails on these ramps and landings which comply with T24, Section 2-3307(d). e) Seven level handicap seating spaces are required to be provided in the auditorium, and in -addition - seven seats shall -be provided for semiambulant patrons. Such seating for semiambulant persons must be provided with 24" min leg room. Handicap seating locations within the auditorium must be approved by the Fire Marshal. T24, Sec.'2-611, Sec. T24, Sec.,2-611 C for unreasonable hardship exception. ♦ J Carl-sbad Plan Check No. 85-522 III October 30, 1985 3. Show location of exit signs and provide two separate circuits and a second source o- supply for exit lighting. U.B.C. 3313(b)2. 4. The lobby is a corridor which is required'to be protected per U..B.'C. Section 3305(g) & 3305(h) 5. Exit doors from auditoriums are required to be provided with panic hardware. 6. Toilet facilities are.required to comply with handicap access requirements. T24 Section 2-511. Also see "Exception" and requirements for equivalent facilitation required.. 7. Detail 1/A7 is required to have a double wood floor it order to comply as one -hour construction. 8. The door to the Managers Office is required to be a 3'-0 wide door ('32" clear required). 9. Existing plywood shear wall to be re -nailed at 2 - inches on center will not be adequate since studs are 2x6 (3" framing members are required, see footnote 2, Table 25K). 10. All sheets of the plans are required to be signed by licensed architect or engineer. 11. Show how required outside air for mechanical vent- ilation is provided with new A.C. units. 12: Clearly show how plumbing vent for new snack bar equipment is run through mezzanine area. 13, Submit electrical load calculations and/or panel schedules for added load. 14, Indicate .(a) existing building load, (b) added building load per Item 3, and (c) size of existing service when new service is riot required. 4 Carlsbad Plan Check No. 85-522 III October 30, 1985 15. Additional corrections from the Fire Marshal may be forthcoming If you have any questions, please contact Gene Meier of Esgil Corporation at (619)560-1468. Thank you. a