Loading...
HomeMy WebLinkAbout2386 FARADAY AVE; 130; 86-285; Permit# "1 USE BALL POINT PEN ONLY-&-PRESS HARD-APPLICANT T.O FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. if e [ 0 _I hereby affirm that I am licensed under u _ provisions of Chapter 9 (commencing with ~ . Section 7000) of Division 3 of the Business 1-· and Professions Code, and my license Is In ~ fuli ·force a~d effect. ·1 I I I I I I ....:.1 II) z 0 ~ a: c( ...... u w 0 ur -I hereby affirm that I am exempt from the Contrac-tor's License Law for the following reason (Sec. 7031.5 Business and Professions Code. Any city or county which re-quires a permil to construct, alter, improve, demolish, or repair any structure, prior to Its issuance also requires the'ap- IIC w 0 ... 3 I w z· 31: 0 z 0 i=•· < Cl) ffi a. :::i; 0 u !I> a: w :,,:,- a: 0 31: plicant for such permil ·to file a signed statement that he is I licensed pursuant to the ,provisions of the Contractor's I license Law (Chapter 9 commencing with Sectmn 7000 of · Division 3 of the Business and Professions Code) or that.is ex-empt therefrom and the basis for the-alleged exemption. Any violation of·Sect1on 7031.5 liy an.applicant for a permit sub· . jects.the appllcanrto a civil.penally.of not more than five hun-dred dollars ($500). n \:as.owner of the property, or my employees with wages as their sole compensation, will' do the work. and the struc-ture is not-intended·or offered for sate (Sec 7044, Business and Professions Code: The Contractor's License Law does ~i~rfgg'Xn~0 _;;o ~~~!rs~~i~gret~i::~1 ~~i:~io~~~~f:~~~ I employees, provided that such improvements are not intend· . I ed or offered·for sale. If, however, the•buildmg or improve-I ment is sold within one year of completion, the owner-builder will have the burden of proving that lie did not build or Im-( prove for the purpose of sale). I D I, as ·owner of the property, am exclusively contracting with licensed· contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply·to an owne.r ol property who builds or im-. ·· .. " · who contracts for each projects with a pursuant to the Contractor's license 0 As a homeowner tam improving my home, arid the follow-ing conditions exist: . . · 1. The work is-being performed pnor to sale. 2. I have lived in my home for twelve months prior to completion of this work. . 3. I have not claimed this exemption during the last three years. ~r M:r":.;~t under sec.-------, B & P.C. -------------- D I-hereby affirm that I have a certificate of consent to self-insure. or a certificate of Workers· Compensation ln-- su_raoce. or a cectiffed copy thereof (Sec: 3800. Labor ,Code) .~OLICY NO. COMPANY D ·copy"rs filed wiu; the city· 0 Certified copy is hereby furnished CERTIFICATE OF EXEMPTION FRclM WORKERS' COMPENSATION INSURANCE (This sectioll heed not be completed if the permit is for one hundred dollars ($100) or less} 0_ I certify1t,at ln'the perJormance of the work for which this permit is issued, I-shall not,employ any-person m·any manner So as to become subject to the Workers' Compen- satioo Laws.of California. NOTICE TO APP~fCANT: If, after making this Certificate -of Exemption, you should become subject to the workers: ,Compens8tlon provisions of the Labbr Code, you most forthwith C<jmply wlth_s_vch prqvisions or this permit §halJ be deem~d revokec:!: I I I I I I .1 I I I I J I I I l '[J ,I hei~by affifm that' th~re is a cqnstructlon lending ffi · agei;ifY {Or th.a.performance of the work for which this per- 0 mit is lseved (Sec. 30~7, !,!vii.Code). z . l&J Lender's Name , , , - ...J ... --• Lender's Address ____________ _ CARLSBAD BlJILDlNG DEPARTMENT APPLICATION & PERMIT 4 -Carlsbad, California 92008-4859 --.. 1.;;i{;' . , • AV.ST.RD, NEAREST CROSS ST . ·I DATE OF APPLICATION!-BUSINESS LICENSE #' /cr;;1-<o· PERMIT NUMBER t-A:--(2.,~ A-~ 1F\ oO .. .. : . 11,,---ri>< loT·,. B!,OCK . ·I SUBDIVISION j..fSSESSOR PARCEL NO . CONTRACTOR··· • · CONT-RACTORS PHONE·# · ZONE I .. ' . -~{ \ (,t)f rFJ:;;-vud-z Oh ~ OWNt?t,1r~~ r ~1°i~ss~ CONTRACTOR'S ADDRESS STATE LICENSE NO. BUILDING.SQ. FOOTAGE ~~ - OWNER'S MAILING ADDRESS l t3W ~,~l?tl;-~~ tett I DESIGNER DESIGNER'S PHONE ~ ). ~¥1 ,,J·· f/4-~C, - DES,rlON i:e;~ 1 VN!:P~·t;,~ ,v . z '3$"--(pt h-f.o DESIGNER'S ADDA.ES$ Sf-~ ' STATE LICENSE NO, ~ D a,1n, .. T15-10-7-7_/fZ__IJ_eec_~ f43Z Ui1ron 12, Z/ 7 ~ i . y/H,11663030 sga~oo F/P FLR ELEV. NO OCC GP EDU STORIES OIJDlSDaB -?~'f'6i" 6G -~1!lia~oo vD NO --... , . -·-. . . . . I I PARKING SPl,C,E RES UNITS I GRADING PERMIT ISSUED I REDEVELOPMENT TYPE OCC LOAD FIRE SPA .. AREA CONST YO ND -.:D NO YO NO Not Valid Unless Machine <;ertified QTY. PLUMBING PERMIT -ISSUE -zt9 ~iY. MECHANICAL PERMIT -ISSUE 1~ SUMMARY/ACCOUNT NUMBER • . EACH FIXTURE TRAP .,v-Jf:--1 INSTALL FURN. DUCTS UP TO 100,000 BTU ,l/,,-_ .,--BUILDING PERMIT 001-810·00-00-8220 IL/-/ - ~ OVER 100,000 BTU . SIGN PERMIT 001-810-00-00-8221 .. ' EACH BUILDING SEWER .. : EAC.H WATER HEATER AND/OR~ I BOILER/COMPRESSOR UPTO 3 HP .t.t-,..-PLAN CHECK .. 001-8.10-00-00-8806 S(',-, - EACH (iAS SYSTEM 1 TO ,µi,tfT LETS ·. BOILER/COMPRESSOR 3-15 HP ' TOTAL PLUMBING 001·810-00-00-8222 EACH GAS SYSTE~ MORE METAL FIREPLACE ELECTRICAL 001-81o-oq:O(F8223 -.. ~-.. EACH INSTA~TER, REPAIR WATER PJPE VENT FAN SINGLE DUCT MECHANICAL ·oot-810-Q0-00c8224 /1 -.. . .. ·EAC·H)H(cUUM BRl',A-KER ~~ MECH EXHAUST -HOOD/DUCT$ (,;_-MDBILEHOME 001-810-00-0Q-8225 ~ER SOFT.NER ·· RHO.CATION OF EA F.URNAEE/HEATER SOLAR 001'-81'0-Qff-00-8226 ---EACH ROOF D~RAIN (INSIDE) DRYER VENT .STRONG MOTION 880-519-92-33 . TOTt.L MECHANICAL FIRE SPRINKLERS 001 ·810-00-00-8227 ' ,,_ ...-TOT AL PLUMBING . I -PUBLIC FACILlelES FEE 320-810-00-00·8740 · · - -, ~~ BRIDGE FEE' QTY ..• E;LEC,:RICA-L.PERMIT .-.ISSUE QTY. MOBILE HOME SETUP . --.. PARK-IN-LIEU (AREA ) NEW CONST EA AMP/SWT1BKR • -CAR PORT _..,. T7' -A. Tl ~-11-TIF "1.-0--/--/ 0 · -Z.OD -.. 001-8·10-00-00-8835 .. . 1 PH 3 PH , AWNING u .LJ r.., ~ ~ --LICENSE TAX ~ 001-810-00-00-8162 YI '. ' -EXIST BLDG EA ~MPISWT/BKR. : GARAGE --·. . -,_ MFF-:Z..., J""/ 880-519·92~57 / 4-"&f·-- 1 PH 3 PH ·. I Ill 241 ,oo ... -.. REMODEL/AL HR PER CIRCUIT ""2--0---··».- TEMP POLE 200 AMPS . ·-r1t11 et CA• -..... ---.. OVF R 200 A"MPS ' ---= -~""" .... ,., Dtnf ESS\Nij ).C"Y .• . T-E-MP 0E£UPANCY (30 DAYS) a,,;;11 ..... --. -~ . -CREDIT·DEPOSIT < ~-~ .. TOTAL ELECTRICAL I ~:.-T.OTAl TOTAL FEES PAYABLE I 1{;{ r ---..-.: I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY Expiratioo. Evsry.permit issued by the Building Olhc1al under the prov1s1ons of this * AN OSHA PERMIT IS REOOIREO·FOR EXCA\fATIONS OVER I CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION l1EREON INCLUDING THE Code shall expire by limitation and become null and 1101d. If the building or work 5' O" DEEP AND DEMOLITK>N OR C():tlSTRUCTION OF DECLARATIONS-ARE TRUE At-JD CORRECT AND I FURTHEl'l CERTIFY AND AGREE IF A PERMIT IS authorized by such permit is not comrhenced within 180 days from the date of such ti RUCT\JRES OVER 3 STORIES IN .HEIGHT I permit, or If the buit\linft or work authorized by such permit is suspended or I ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON-abandoned at any lime a er the work is commenced for a oenod of 180 davs ~ STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND APPLICANT'S SIGNATURE Jf. OWNERD CONTRACTOfl 0 APPRO'I/ t:·.Jt: ... •· " I\ .rr17r I f-1 ~ ~ 1· KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILlTIES, JUDGMENTS, COSTS AND 1.....4_ I EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE BY PHONE 0 -I GRANTING OF THIS PERMIT .,., -I I I ~ u: >-ro 0 C. E Q) 1ijp ~~ 0 . (!} ...., C Cll .2 C. C. <( I -" C 0:: 0 en en Q) en en <( I s: Q <D >- Q) 0. C Cll C i.I· s C Q) ~ (!} -0 0 Q) gs C ~ .c 3: .... r~l'if~[l~~~N~~ut~~~~;~c~l-L .... ·:;\ .//~~~~=~-~~:$JEl;L.', :::1· _ ',,, ::,r. '~·-·· ,~ r , • ;+, -":;--; .._, ·- 'l)AT~-L [~.i~~f.>;~91"g~:. ·:~: . --;~:: ., __ ._ ----,.., 1·· _.i. ':-t:' '_ ~ : /: '·--~~ _, . . ,,. :t,. . ............ _, 1. :.· ~·-. ,-, ,!,.J. ,, -~·'" --, -. .,-,,.-.-.----. -..,_ ""', ;.--, ~ x:..,-, ·,·t -i: • ~ •. .c. : \--~-:.. ,; ·~·--' •• v .•:::_; -··FiEL'iz> iN$PEG;fl0N,REGOR0 .... T" ··~ .• • ·, ~ 'l:: ' -1·~: '1·--~~ .. ·.:-:.·,_.~,;~-:.:: _'-,.~ ·=._:..-_s__:_:,_:_ ·; ,:·"}~ ft-.. ~,,,.~~--' ( 1·· > -, l·i·- ',-G··. ~.J;.,. e..,or_&":~ _;...... .. .,· . ., . \ .,,-, 'r> : , . . . · .--.. o;'fi:, 1' .... ~-"'--<:,,,_ "< .. -:-. .. ·, \ , ih·.\. ,e',.\:·:. . .. ,,, .... ...... . .. ·_.;/-~>--~--.... : .. ,c,~~J .. ~:.:.Y}::~:_i ... -~:l ,,, . ~~·- .,'-· .. -/:'· . ,-,-,---·,:·,·~ ' , . > -~---'-1.----'- ,, ~~ '-r: --·, ,j..·_ . ; ~·· -~~ ... :: >r:.~-~ :,. !N,SP~C:t'OR'S :NOT:ES -···-·· ·.-,:-"".. ~ ....... ·,: __ ~; ,\ ..• ~ •. ,~UNt;f~:6.F[GROV'.t::.< ·,_:,:.:., <.<::Jc:~·-,~·- .. ., ,., '·,;'.\!;' ··,''!: ,. ~ , , _:,.. :i~~_ouifi.Erfsi~f,~~ ,~iPri~:roi6~-~:-~·,:'.:-',, . ·.--,'-;,:,;- ,>~.,-:_~: ,~~:-· -.. · · :ftEq.:;i=-c: 'N.§.:P,s.g:r.:gR:r .. , _-. ": ,: . ' ·. ,, ; .,, . , _ .. '"~,\ /~.; .. -~:-·/ ·:~1·. ;~ ,INSF'EQ!ION ·:, . Cf:iEGKED: .APPROVAL ;.: ,OAl:J:: · .:".. ,. .--:·-·, ./ · ;r-,,-, .:._:::· ~.-: · ! · '.~dt~~::~blAtL!·A~;E: ··;:/ ,,, ~~'./:;·\,../: -;·::~:::._· '::·, .. , ; , .... ,':<-.},t\: ... '.:~:\,-:~: 7,t :~T J, '. ,t'' :::~ \'._ ,;{ t· If; :-.... .,.·_- r~-- .---.. -~::c·L SUB::FRAME:tJ :FLOOR~. ,i;~L~ElttNG ' _·-:. :-:., -;_·c:' -~/:~,,~,-;-,~·~~::-, -· >~:-:·--~-~-,··~:· ~---~ ~:;~: -:~;:;·~~,-:~~-r: :.!·: ~~";::· '" :. ,~HJ;;ATHJl'.m _: ,.PJ~0Qf .,:._. :c;:J, ~!:i!~AJ:k •:)l,1&{~~~~}"-.. ~:•···:J ·-·· ~ :,-, '" )-' (· i'\;ilNf:ERiOFfLATH &/m~YWALli:/· ::1><; , ' -~· • -,. -, \,---• _, .,, .. --___J:__~ . -. --. ----. ·. ~::~. :: .. J,,:,: ':: .. < . .-:·:·· >: ... '.'.. ,;~ .<_:f ·~·~-,:• . . . .. .· ,, .. J?L.UMBING ., .. ,, ., .. , ... ·,' --~:·.;:, --: '--~, __ !., ... c.J..; ,;.,_;~~~p /:!-~ -· ·,,,.,,. ._.J.-.... ,1,::C" ·--;.-:' PF.llORTO" · · .. ,, ' J. s.·'.• ..... ,., • « .. ··-t.'i;'A,{:} 'l.: "'t!;..;r,.,, !ii tJ; -• • • , ,; · .. • "" "' '" · '; ., ;' .. ,, ·".'·'· .· ,'"' ' •. .. :, ' •' • ' -:" ",._P.t; lll ;;i:i:.t:..-'?iH~ ;,;"M-,;~. : .. ·. ;· ,· ,•. F..0!:J,N!)P.,:rlQ('J-INSP ·... ---(;ti 1[· ~-~ . . . ,...,.. --i-P-!h;: -. ··-· ·-. l ..t~iicJ~hjf~~tiR,i:r~_:-:· ., •" .. ,:~ ~!i·,-.~~~-~::~~~;~;.~Ii-i_i;:.~ :-t , ... , .. t<:e'·:~~~;:,:\i··:·.\ J;~s;;i1f:E,D: .:, ;. .. ... fl. i; .: ~ :: ~ 1. '-: . <E· '~.:_·.·.;-~·.ii ·::i: .. ; ~;: ~i~1}gi,[~ONED ·... · :;. ..i; f'!i_'fiT._--j <\ ;: ·: ----~~.; -1\· --! ~~. ~-~. ,_, . : . FIElD!WELDING· ,·_:.'·~::.~ .. ~ ..!'..-· ..... ,, : :,. _ --e '~ ",..., -~":3~i, "": -?-,;-_/ '... ,-, ,·, •_.:..._'_-____:_ -'--' --=---±.__• ___ ,_. ____c_·-----'-~-:.·::,:::::. ~- · .( tf SEWER ANO :SI.JCt) : -: . :o .POGO:> ~.-.:~. ,,:' .. '; .. , ;·. · ... : ":.'·,' · .. :·:: .:· . ·.:. ·: -~.-":: \"'..~--~.:.;:,'. ... :QN[)l;RGB,9UN.P: .. ~J:;I _WA§TJ; ... QW,ATER ,;~J¢P. gl)t :. ::~: l;J,: WA&t~. :;:~., .. :' .:':c;fW~T~B-~,:- , TP~)~ND-SH.©W.E~ '.PAN ' -:v ·. ,· ·{; ·: <~;.; .. \.. ~- ... ·-,, ~- ~ :('X ,;,:J· .-,;" ... --... ~, . HIGH, S:PRl;:NG'f.i,'f :-·B9f:fs; ' .-:.; · : ,-. . . . .. . . ' :~~P;i~OlA'L MASor,iRv' ... ::.1 1 ' ' ~:, ~ : ' '' .•.. \. q .. -• -~--~ --~:. -~-_.~~~ .2 ... ----.... r---:·/-':' ,, ···.1 ,..,_:\_.__!. ,·~ ... { .. /' ¼ :ift~"l'... GAs·test::-.. ,-· ·: ·:·.~ .. ; ,~ "-cf' I I a\),vi.r~@-~l:i l;Ai~~:; 6 _,&pl.AR WArE~_., ---. · · · -· --... .'•l'.,, j I ' I I' 'I .. ' ·.. I . ' '. ,. ' '.;.. .' ·,;"·, ... : ~-~----'.-·_ ~, ~ .. -.~t-,: ":'. :, .. ., _.. ..-,. ' . ' c,-•, :~tl~.~: "l,' 'f . ;--; j:,1ctst:A1s$oi\J;;;· /2,' \J ]#~j, ,,.,_.· ~~-::,_ ._,_t_~ _ __!'._~ ,; 'i!, 'l //~I~~. Ete·cTs1·eAL. _ ,-, ... ,. . . , ... _· <->~~ . . >: .. , o_:1:.~·~ctR,q UNoi;~G.RQ~N~-· · .et;l.iFfE;R.: .. : --:·· : . , · -,~=-~ · ·,1 · ,_..cl_'._.__-~ .. !0[it!~icz;~\Gt@6! r1a~:r~~f ,: ; , ; : :::_ ' · ···· . : ~Si~. ;,h '. ,. ';•'" i; ,,. , •. 'i -, ' \.,:~ r:, ..... ,, ,, -. ')'· MECl:IA_N_I_CAL_ : .. 1· 1 · ·I . . " . , .. ·" . '' ,, ~:, I<;~<. . k·,:· . , -, . . <" ~.; -•-\'., . ry~ •I "-,i;.-·' ~-·~t:,.:~~~~. -Z-~·:·: ... /.t _, ~ _,_ '--~ . '~·· ,} ' :.-·· .... · ... ·-' .,1:,,- • -.1,.~, -:~-. ¥- ::-:· ···<·' . , . --~ -~ '":"',.;-.., ,,- .!i:~t:-•'l, \" ,\·.-J! ,.-!'f ~~r .c~-;-:..-;.-~--·. ,..·,· ... -.,... -~-, :· .. ;· . .. ·,•·: .· .. ;:, . ,. ~ ";;f-:·-.-'-~-· \ ... \-~\c-~ ;; : .\ -~~ : . ._,__ t" -~ , .... _.-!·~ 1'' J_f J \ .' ~,~ .. _ '~· ,\ _"l_, ~·. ', ,,_;" ,{ ~ t -t ·,j t~.-~.; :;· ,,· ,.: ~ ,,'.•_,1, ;:_·1;:1.t?.!JCJ.~'f!Ja,.E:~,; ·. o.·fiE.F.-PiPJN,G -···~,.,--,-.,--=---c---,,-~~,_.,...,,~..,,,. ----:~::t~!!G9tti~~!:EMS' ;)G' ;, ~:::~t:\ :t.~:. )/t:Ht~·t:::? . /' :: . . . >; ,5jlfj . i\it\;,.:.~ ;; .; ;;'" :; ,· ~---, , :C"1.J,,t'i=QR,:F.lN~L-({vSi!i;pT/Pf/· W,HE,f{.ATL4J?RR .. OJ{ij_i'A1jE i:·~·~, ;, ; ~-~~-:'···. · ' ~ t >~~ ··:· . . :.(•,-1, , .. i;~; :: -L, ····; PLUM~ING-. · -· :~ , , ITEMS~'ABOVE.HA-VE.BEEN'.A'PPROVED. ~.·. ,:. ' .-,. t ··\, ·. ~';;,;~ .. · ·, r ... · ,,, . :.FINA(.;'. ·r ... -:· < J·-: "'",·--'-'-'-'·..,.· -"--~~~;.;..,.+,,+'-'.:,,-<---'-'--+-~~~'-I--+ ii ryl"~+,--',-,,-<J-\,,r-+U~~~=-.,; ,,,' :· .. . . • . r ····· ,. ... ~-· "·._.~-:.:{'h.~,.;_ ...... 1 "· • ,<'\\·· \',1,.,::; ~lJ:CTRIG:A.L ':~ '.,, __ :•, ,. jv1~PHAN!P.A~ '~:-~AS::, ~ . -~ : ;·<-.. ~ BUll::DI NCf ..... ,. i,;,;;,,-,;:-:,,--,-,,+-,,+---;.-~'---',-',-7'-+-,,<"--,,-,a.....,.-,1----;,;,..,.-'-''',,' ',"'a,,· '·'""··-+:",.,;a."..a·,;;--:..,.,~ • "· ·-V\', •• \ -,;- •• •''I,.., ·-l\ ,P (, -'.' :•7+---:-:, \: . ., .:,:-,,· ,, J .... +:. ~ 1 \ • ....-<·;-).:'":,:,,_~ ...,;_; • ~ '• • .f' , \ ~.t_,.V. ). . .. ,. (",t,"'-,J V \'·_, ·0 . :~ ~P~CIALCO~D.iTIQNS 0 >;_,;l!:{ '; ~~: ..... ..... ,. I )' ~.:·-~--·<·· '>·:i;;rJ-...: ·_ . ~-. ..... · .. · · > .. ~-: _ -:,."-· · · ·.,:· ~~ _ .. ,,~ ~- -· 1.• ... _\ :_-_._·._ ~ -~---ff,~-·'.. . ¥'• ,,. ' _, ••• i' : -_._-; r·· -,. r .-. ,, __ ,,_k ,_' + ,:f. ... ~$,_ r' .• _l· ·,-i: _:_. ~.-<.~ ' .i,.. ,· .: ... :"' -'-~.; ... '/.-.•:-,. .f 4 . f ··~·-•• ,11. ,,_-·<} ·-· -··' ~ 1 v-' ,, ;~ "'U l. '' ..,;, ---,.;: ---~--~ •"" )-;\ ~ f!': . ~,.: ~(~ }-~ :-~ /;' ,, --~ ... ,•. :;~, i' ·l .. )lL" ~-! ~~.: :· ~' I ~...l ' .... ~ ~" .... \., ·w· ' i ','":. ,-..,_, -_-11.: -· :.-: - ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560· I 468 DATE: 7/; ~jg{? I I QAPPLICANT CO ·JURISDICTION:::> 0 PLAN CHECKER D FILE COPY QUPS JURISDICTION: C J41-IZ-L.s e,..q-£? PLAN CHECK NO: 8&-C::8'5-_zz: PROJECT ADDRESS : ;2 3 ,? o F,4,z A DtJ ~-t f:k./t::, D DESIGNER . PROJECT NAME :' II D D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified ______________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff-did advise applicant that the plan check has been completed. Person contacted: Date contacted: _______ Telephone# REMARKS: fr{}2M,l9vT1.~ 7}+6' rr>Y2r1Af: I 1 2. ~ w,a-rzg F""1 Ll9J LIJ1TI4 8 4 -l:, :;, 2.. 14-._; -n+,4, 1 '$... Hou.) ""t"'m-,,:~ wa. 1:f rn cb:2 .,~--:::r-2 • r BY: ~VV\ G1L.S-W11e+N ESGIL CORPORATION ENCL: _ __,'R:.;;;.......;.%}.S--'-"'--__ _ • ~·· • ESGIL CORPORATION 9320 CHESAPEAKE DR .• SL'ITE 208 SA.N DIEGO, C.-\ 92123 (619) 560-1468 DATE: C/'2d /BC:, j OAPPLICANT JURISDICTION JURISDICTION : C ~.13 Fl.Cl CHECKER 0 FILE COPY OUPS PLAN CHECK NO: 86-~!3}6 -:Z::: PROJECT ADDRESS: 2380 E-r/:J-Z ~.OR'-1 eue · 0 DESIGNER PROJECT NAME: {/AJ/qLOBG' /.lj D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified----,---------,----are resolved and .checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy· of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: ::r, 'tl:qwv,,xzp a $·;;soc.. I 4~'? U \~\ON %--r, Esgil staff did not advise the applicant contact person that plan check has been completed~o-r-.+Qe. -nl-'A-"!-1 "t'-1\'A\L-HJ.:fr, Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: _______ Telephone J ________ _ REMARKS: _________________________ _ BY: SW\ c; 1 l-SH ( A:J-4 ESGIL CORPORATION ENCL : l, s--<" --=-'-=-.,;..._ ___ _ TO: ::Ti" t±:o w M~ o ~ A~> J 4-'3 "Z t )1:,) ON ~,. JURISDICTION OF C4JZ.l-SBqO APPLICANT COPY JURISDICTION PLAN CHECKER COPY 1 ESGIL FILE COPY TENANT IMPROVEMENT & INTERIOR ALTERATION CORRECTION SHEET A. Plan Check Number c8G -z 8-S--..r ------""'----"'----=------------------- B. Site Address Z:380 ~A-Ofrl( c. Owner J<oL1-CCJ' D. E. F. G. Building Code Applicable ---------------------1982 U.B.C. Occupant Load A/, ff, Stories tJ, 19 1 --------------------a------P rev i o us Proposed Proposed Occupancy_---,-,g_,..._2-___ Qccupancy 0/./-~-Z L use 01.t:=t::=;c.t: Type of Construction __ ;V __ ,_f}_, _____ Sprinklers: ___ Y_e_s _ __,@_N_o..,,__ H. Allowable Floor Area !'{, ft ,(-r,.J,) Actual_~\-1-1D_7~'].__ ____ _ I. Basis for Area Increase /1/, ;4, ----------'-------------------- J. Remarks ::5,n &L L t,/, Date Plan Submitted:to Jurisdiction/14N,G/9 to Esgil 4)61). C./11 //?(p ' .. Date Initial Pian Check Completed fiz;, t,,/zo/$-t, By .:::J;-YV/ I I Applicant Contact Person L«(NN /3N€}f,qetTel. 235 G/~(p FOREWORD: PLEASE READ 1. This plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and State laws regulatin6 energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. 2. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. For information regarding those departments, please contact those departments. 3. The items listed below require plan clarification, modification or change. AU items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Section 303(c), 1982 Uniform Building Code, the approval of the plans does not permit the violation of any State, County or City law. If.. Please submit two sets of corrected plans and enclose a copy of this list with your notes indicating where corrections were made i.e., sheet, detail, etc ... return corrected plans and documents ONLY to the locations checked below: g /f 0 Esgil Corporation at 9320 Chesapeake Dr., Suite 208, San Diego, CA, 92123 Telephone (619) 560-1468 \ @ Jurisdiction Building Department 10/22/85 I / I I The responsible designer is required to sign each sheet of the plans. A State-licensed Architect or Engineer is required where there are structural changes to an existing building or a structural addition. (Business and Professions Code) Provide the correct address and suite number of tenant space on the plans. Section 302 Provide a note on the plan indicating the previous use of the tenant space or building being remodeled. Section 302 When the character of the occupancy or use changes within a building,the building must be made to · comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building will comply. Section 502 UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall in- clude all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distances from the building to the property lines and the location of tenant space (or remodel) within the building. • I I If the tenant improvement area will not have a comfort heating or cooling system consuming more than 5 BTU per hour per square foot, note on the plan "Tenant Improvement area is not heated or cooled more than 5 BTU perhqur per square foot and is exempt from Energy Conservation Regulations". If the tenant improvement area will have a comfort heating or cooling systernconsuming more than 5 BTU per hour per square foot, note on the plan "Tenant Improvement must comply with Energy Conservation Regulations". If the tenant improvement area must comply with the energy conservation regulations and the exist- ing building was originally constructed in com- pliance with the energy conservation regulations, provide two copies of the original Energy Com- pliance Documentation forms. If the tenant improvement area must comply with the Energy Conservation Regulations and the exist- ing building was not originally constructed in compliance with the Energy Conservation Regulations, address the appropriate items that will follow. If HVAC is to be installed, provide~ ~~of energy conservation compliance forms"2:},(3}(.j/ 4, 5 and 6. Title 24 Section 2-5312. If HVAC is to be installed, provide two sets of HVAC plans. Title 24 Section 2-5306. • I I If lighting is to be installed, provide two sets of energy conservation compliance form 5. Title 24 Sections 2-5343 & 2-5344. If HVAC is to be installed, incorporate in the plans or specifications, the attached "Title 24 Mandatory Requirements". If HVAC is to be installed, the required energy documentation required to show compliance with the energy conservation requirements, is required to be signed by the California licensed person responsible for its preparation. Title 20 Section 1403(a)l. If HVAC is to be installed, recent charges in the regulations required specific signed construction compliance statements be filed with the Building Department prior to use or occupancy of the im- proved area. Incorporate in the plans or specifications the attached "Title 24-Construction Compliance Statement Requirements". Structural design calculations are required to show code compliance if any of the following conditions exist. Section 302(b): (a) Alteration of existing vertical or horizontal load carrying structure. (b) Increase in live or dead loads on floors or roof.. · · (c) Other ---------------------- - ELECTRICAL Submit complete one-line diagram of service and feeders; show conduit and wire sizes; specify aluminum or copper conductors and type of insulation. Indicate sizes of fuses and/or circuit breakers. Submit electrical load calculations and/or panel schedules. Indicate ampere interrupting capacities (AIC) of service and subservice equipment. NEC 230-98/110-9. Add note to plans indicating: a. All package A/C units shall be labeled by a recognized electrical testing agency. b. All light fixtures installed in suspended ceil- ings shall be secured to the main and/or cross runners with seismic clips unless installed in accordance with other approved engineering. c. All circuit breaker switched 120 VAC light circuits, must use only type "SWD" circuit breakers. NEC-110-3b Indicate (a) existing building load, (b) added building load per item 49, and.(c) size of existing service when new service is not required. ' I TITLE 24 MANDATORY REQUIREMENTS (To be noted on plans or specifications) HVAC Controls Sec. 2-5315. (a) Each HVAC system shall: 1. Be equipped with at least one automatic device for reducing HVAC energy use during periods of nonuse or alternate uses of the building spaces or zones served by the system; 2. Be able to maintain space temperature set points from 55°F to 85°F. Two or more replaceable fixed set-point devices shall be permitted if installed so as to maintain space temperature set points in the zone that they control; 3. Be able to provide sequential temperature control of heating and cooling capacity in each zone, if both heating and cooling are provided; 4. Provide a range of temperatures up to 10°F in which no heating or cooling is provided to the space, if the HVAC system has both heating and cooling capability; 5. Be able to terminate all heating at 70°F or less; and 6. Be able to terminate all cooling at 78°F or more. EXCEPTION: Multiple zone HVAC sytems requiring concurrent operation of. independent heating and cooling _systems need not c'omply with Section 2-5315(a) 4, 2-5315 (a)5, and 2-5315(a)6. (b) Zoning. Each zone shall be provided with at least one of the devices specified in subsection (a) to control the HVAC system which serves the zone. Each floor of a building with conditioned space shall contain at least one zone. Ventilation Systems Sec. 2-5316. On mechanical ventilation supply and exhaust systems capable of moving more than 5,000 cfm of air, auto- matic dampers interlocked and closed on fan shut- down shall be provided. On gravity ventilating systems, either automatic or readily accessible manually operated dampers in all openings to the outside, other than combustion air openings, shall be provided. Doors and Windows Section 2-5317. (a) Doors and windows between conditioned and uncon- ditioned spaces, such as garages and closets for central forced air gas furnaces using outside air for combustion, shall be designed to limit air leakage into or from the building envelope. , .. , Control Devices for Indoor Lighting Sec. 2-5319. Controls for lighting loads within the building envelope shall meet each of the following re- quirements. (a) Each area enclosed by ceiling-height partitions shall have independent control of the lighting within that area. (b) Each area enclosed by ceiling-height partitions shall have at least one readily accessible manually operated switching device to control lighting within the area. For lighting controls, "readily accessible" means located so that a person using the device can see the controlled lights or the area being~lit. Switching devices in addition to, but not instead of, the required readily accessible manually operated switching devices shall also be permitted. (c) The general lighting of any area 100 square feet or larger in which the connected lighting load equals or exceeds 1.0 watt per square foot throughout the entire area shall be controlled so that the load may be reduced by at least one-half while maintain- ing a reasonably uniform level of illumination throughout the area. Readily accessible switches, -that control each luminaire in a space with more than one luminaire, orthat control each lamp in a space independently meet the requirements of this section. (d) In all areas where effective use may be made of natural light, lighting circuiting shall be arranged so that units, in all portions of the area where natural light is available at the same time, are switched independently of the remainder of the area. Occupant Operating and Maintenance Information to be Provided by Builder The builder shall provide the building owner, manager, and the original occupants a list of the heating, cooling, water-heating, and lighting systems and features, materials, components, and mechanical devices conservation or solar devices installed in the building, and instructions on how to use them efficiently. The instructions shall be con- sistent with specifications set forth by the Executive Director. Water Heaters and Plumbing Fixtures Water heaters, showerheads, lavatory faucets and sink faucets must be certified by the California Energy Commission (Excluding: waterheaters of the non-storage electric type and lavatories in public facilities having devices that limit the flow of hot water or have self-closing faucets or having devices that limit the outlet temperature to a maximum of 110°F) Section 2-5314, Table 2-53G. TITLE 24 CONSTRUCTION COMPLIANCE STATEMENT REQUIREMENTS (To·be noted on plans or specifications) CONSTRUCTION COMPLIANCE (a) Prior to occupancy of the buildin~ the person responsible for the construction or installation ·shall provide the building department a signed statement, showing the building permit number, and listing all the manufactured devices in- stalled, including the name of the manufacturer, model number date of manufacture, manufacturer's stated efficiency, including the source cooling power index, source heating power index and fan performance index of each HVAC system. In lieu of the list reference may be made to the plans and specifications, if all the above in- formation was contained in the plans and specifications. Each document shall be signed by the person re- sponsible for its preparation. The signer shall be a civil engineer, mechanical engineer, electrical engineer, architect, building designer, general building contractor, or specialty con- tractor, licensed or registered to practice by the State of California; oc shall be the building owner if he or she is allowed by law to prepare the document. If more than one person has responsibility for building design or construc- tion, each person may prepare and sign the document or documents applicable to that portion of the design or construction for which the person was responsible; or the person with chief responsibility for design or construction may prepare and sign the document for the entire design.or construction. INSULATION CERTIFICATION Prior to occupancy the insulation installer shall post in a conspicuous location in the build- ing, a signed certificate containing the build- ing permit number and stating the insulation was installed in accordance with the approved plans and specifications. The ce~tificate should also show the manufacturer's name, material identifi- cation, "R" value and, for blown insulation, the minimum weight per square foot consistent with manufacturer's design data. Date1 q/zft(p Jurisdiction C412-~BO Prepare~y1 ....:::kn VALUATION AND PLAN CHECK FEE CJ Bldg. Dept. 0 Esgil /'1)/ -;::;,_ Q,5--_r-PLAN CHECK NO • _____ o_ 1u:, __ ~....:·C.,_/ BUILDING ADDRESS -Z 3 e,o PAr2r.:JJJA'1' ;:Ju&'· APPLICANT/CONTACT Lt,,'IV rJ PHONE NO. '28 S-t::>/ &:,l, BUILDING OCCUPANCY 1 /3-"2. DESIGNER PHONE 11 ------ TYPE OF CONSTRUCTION V-1-/ CONTRACTOR PHONE ----- BUILDING PORTION BUILDING A.RS.\ VALUATION VALUE MULTIPLIER - .) -_, J 11;~ / lvt-;1b-- OPr1c8' -r:1, /07/ rr' ~ /~,;Jt) -4-~ - I i .......... - I I I I I I Air Conditionin2: Commercial @ ' Residential (cl Res. or Comm. -1 Fire S'Drinklers @ 1/2'~v1 I ' I -• Total Value ~ fee Adjusted To Reflect Building Permit fee$ 0 Energy Regulations (fee x 1.1) 0Handicapped Regulations (fee x 1.065) ...,,~o-1/-1 ~ $ plan Che ck fee_......$ __ 7 ___ 9'_,_(p_tJ_· _. _o_t::---;--(-w-~---r!.15~012-_c...-'--+1-'--D-I--=-$ ___ _ COMMENTS,_:--------------------------- 8/4/82 ' i PLAN CHECK NO. 8fo-285°'ADDRESS ,z?r3,8Q .;:;.,~ DATE PLANNING V e ZONE: ~f~. TYPE OF PROJECT: /~,/2/~ SCHOOL DISTRICT: SAN DIEGUITO ENCINITAS CARLSBAD ~ MARCOS ---- C w 0:: :::> ---+-o __ w 0:: V) ---z 0 --I-~ u cu w == 0:: -~ cu 0:: > ..... O a, co U 0:: C C w 0:: :::> 0 w 0:: ti) z 0 I-~ u cu w == 0:: cu 0:: > ! 0 cu co u 0:: C SETBACKS: FRONT SIDE REAR DISCRETIONARY ACTIONS: ------------------------ REDEVELOPMENT PERMIT REQUIRED: ____________________ _ ENVIRONMENTAL REQUIRED:_....;--..---.~------------------- ADDITIONAL COMMENTS: ----------------------------- OK TO ISSUE:_..pf _________ _ DATE: <el t( ff: ENGINEERING LEGAL DESCRIPTION VERIFIED? ~ w APN CHECKED?_~"'~r_:::_ ______ _. P.F.F.: /J/f¾ PARK-IN-LIEU QUADRANT:__!}j] , FEE PER UNIT: ___ _ RIGHT-OF-WAY:_ ..... N __ /2.._'A _________ TRAFFIC IMPACT FEE PER UNIT: __ '/12{)() EASEMENTS: }J~ DRIVEWAY:.J&!A----------- IMPROVEMENTS: tJ ~ -.:..-i~------------------------- FIELD CHECK DATE: INITIALS: -------------- E.D.U.: .l'Y\.O ~ tN>.//;J --0 LATERAL: lU,&r: ~ I .,. GRADING PERMIT: ,J ~ --+------------------------- Oil. SEWER: INDUSTRIAL WASTE PERMIT:_AJ._~,_'A, ___ _ GRADING COMPLETION CERTIFIED: ----------------- DRAINAGE: ----i~------------------------- A DD IT ION AL COMMENTS:__];_hf_...., ___ 2 __ 0 __ ~_rii.,.....¼ .......... ~ __ i6 ___ ~ __ 10 __ 00_¢ ___ =_2. __ o ___ -ra ..... ,? __ · ,_Jt ...... ------ 2.cf''flr,a 1 p -dl2a) " OK TO ISSUE,~ DATE: rik//Jft7 (.__:;::& -,r---i11------------- DPD2:DPD6:04/15/86 ----- 1200 ELM AVENUE CARLSBAD, CA 92008-1989 «:itp of Carlsbab FIRE DEPARTMENT PAGE 1 OF _J__ TELEPHONE (619) 438-5523 APPROVED DISAPPROVED PLAN CHECK REPORT PLAN CHECK# 8'=, -~ ss-: ' l , , , , -1 ""' ~, 1 r PROJECT.f/./t"j tob tf i ()Avt? ADDRESS J., 2 r<,'1 CAt'AIJ_/41 ARCHITECT ::r. HolN/ll'Q AHGlt ,,vr,.s ADDRESS ,t.;·_;;:1 vr-:, ,:,tJ p~ S '-' t i"."°e PHONE ______ _ OWNER /fe II · (>o. ADDRESS . $,w {k~~o 9;1101 PHONE 21J"':. (.,,/'k STORIES r: OCCUPANCY cs-P. CONST. -~v_ ... ~tJ ___ TOTALSQ. FT. I'!,. ~8 f _Ji(SPRINKLERED 1'( TENANT IMP. ---'--=-,-_rJ ____________________ _ APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: PLANS, SPECIFICATIONS, AND PERMITS __ 1. Provide one copy of: floor plan(s); site plan;· shee~s ___________________ _ __ 2. Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. __ 3. 1 Provide specifications for the following: ~ 4. Permits are required for the installation of all fire protection systems (sprinklerfi, stand pipes, dry chemical, halon, CO2, alarms, hydrants). Plan must be approved by the fire department prior to installation. --5. The business owner shall complete a building information letter and return it to the fire department. -X-6. -X-7. FIRE PROTECTION SYSTEMS AND EQUIPMENT The following fire protection systems are requir~~ ) / lill, Automatic fire sprinklers (Design Criteria: _...,N.J.'--"l_.f""'~'-'---(.,_··_.,~l~Oc..,1,-l~t ..... ';~; -0-;1-~\.~i+:~~l:_t_r~· -l~l1~Z-11~r.~O~---D Dry Chemical, Halon, CO2 (Location: _______________________ _ D Stand Pipes(Type: -------------------------'------0 Fire Alarm (Type/Location: ___________________________ _ Fire Extinguisher Requirements: ·jl One 2A rated ABC extinguisher for each &Oo o sq. ft. or portion thereof with a travel distance to the nearest 'extinguisher not to exceed 75 feet of travel. D An extinguisher with a minimum rating of ___ to be located: D Other: __________________________________ _ __ 8. Additional fire hydrant(s) shall be provided ______________________ _ _yg_ _.)!.10. 111. EXITS Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. A sign stating, " This door to remain unlocked during business hours" shall be placed above the main exit and doors I .UI, N V\ l I l 1-.. , , • .,., AN , rJO 11 A 1 , f:J 1 , ,1 pr tl.Pt,.0 t~d IJ.... EXIT signs (6" x ¾" letters) shall be placed over all required exilts and directional signs located as necessary to clearly indicate the location of exit doors. · GENERAL _).{_ 12. Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code. ~ 13. Building(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing i.; to be d0 ne, comply with Uniform Fire Code, Article 81. · __ 14. Additional Requirements. ---------------------'---------- , .. ) \ Qb(l(U1rTcc ' --15. Comply with regula~i on attacherl,st)eet(s). ~ 7; I '/.., I/ Plan Examiner ~ ~...' _,,,,.-0:,-,~t, -<,.)' Date ____ _....,[l'--_..__ ___ _ Report mailed to architect ___ Met with ____________ _ _ Attach to Pfans DOCUMENTATION FORM Form4 HV AC IYITEMS COMPLIANCE (Cornpleta for MCh ay111111) PnrjNt Thie u,I.I It, 1-o(S (; --/ C -'= Locadon /~O LL 7oOO oFFtCs By:)&. '"""1Dllipr 4?W'.0t<A PR,r?t,; /wc-.>1[11,,,,,< ~7Jf.1rJ1;fttl1~~-, Qaallld 11W ---- DUIGN CONDITIONS Building occupancy type (Table 1 of Appendix I) Project Latitude (Table 2 of Appendix n Heating Degree Days (Table 2 of Appendix I) HEATING LOAD DOCUMENTATION (Attleh Cllculltion1) Outdoor DesilJl Temperature, Winter, °F Wind Speed, mph Wind direction Indoor Design Temperature, °F Temperature of ~djacent unheated spaces, °F Transmission Hea~ing Losses, Qtu/hr Infiltration Air, CFM Heat Loss From lnfiltr_ation, Btu/hr Ventilation Air, CFM Heat Loss From Ventilation, Btu/hr Outdoor Air for Special Processes, CFM Heat Loss from Process Air, Btu/hr Other Heat Losses (describe), Btu/hr Heat Gain from LighU, Equipment, People, etc. Btu/hr Total Heat Losses, Btu/hr COOLING LOAD DOCUMENTATION (Atuch Cllculetionl) Outdoor Design Temperature, summer, dry bulb, °F Outdoor Design Temperature, summer, wet bulb, °F Indoor Design Temperature, °F Transmission heat gain, Btu/hr Infiltration Air, CFM Heat Gain from Infiltration, Btu/hr Outdoor Air for Special Processes, CFM Heat gain for process air, Btu/hr Solar Heat Gain Through Windows, etc., Btu/hr Heat Gain from Other Sources, Btu/hr --f. wrr~ voir-11..A.T1 oN µ~'"Jl,r <,A1t-.l Total Cooling Load, Btu/hr DIii ---- !, -s 81 II, 9° 2.., ' 78 2, o?'3 --- 11, // 0 ,_2ofF-4 TEMPERATURE CONTROL Anidi manufacturer's data or other, give specification or .drawing reference which shows in detail the following information: • capability to sequence h11ting and cooling • ttmperaturt control device Ht point limitl • temperature set point range betwffn full heating and full cooling • setback and shutoff controls • capability to terminate huting at 70°F and cooling at 7ffF REFERENCE (P181orlhett#1 m-1 Indicate drawing or specification reference where the temperature control device requiremenu given below are documentad. An automatic temperature control device shall be provided for: • each separate HVAC system M -) • IICh zone SIMULTANEOUS HEATING AND COOLING -,.J / A Tht following requiremenu apply to the use of new energy and need not be complied with when recovered energy 11 used to control temperature. In uch cae, when resetting hot and cold deck temperatures, on representative zont may be chosen to repr1111nt no more than ten zones with similar heating or cooling requiremenu. Concurrent operation of independent heating and cooling systems serving common spaces mu~t provide either or both of the controls given below. List reference specification page or drawing number where control requiremenu can be verified. • Sequential temperature control of heating and cooling systems • Automatic reset of heating temperature, to limit energy input only to that level to offHt hut IOSI due to transmission and infiltration. REFERENCE M. -J Reheat 1y1tem1 -give reference specifications page or drawing number which will show compliance with tht following whtn reheating 20% or more of the total air in the system. • When 11rving multiple zones, controls must automatically reset the cold air supply to the highest temperature level of the zone requiring the most cooling. • Single· zone rlheat systems shall be controlled to sequence h11ting and cooling. 17-71111 .... ,.,,_. Dual-duct or multizont systlml -give reference specifications, page or drawing number which will lhow coms,lianc:e with tht following: • . Hot deck temperature -muat bl automatically raat to the lowest temperature necesurv to aati1fy the zone requiring the m01t htlting. • Cold deck temperature -must be autorNtically reset to tht highest temperature necasarv to satisfy the zone requiring 1he moat cooling. REFERENCE RICCJDling systlml -give reference specificatioN page or drawing number which shows compliance with tht follawing if recooUng 20% or more of the total air in tht system. • Controls must automatically reset the temperature of heated supply air to the lowest temperature necnsarv to satisfy the zone requiring the most heating. NVAC SYSTEM RESTRICTION~ & SPECIAL REQUIREMENTS Several HVAC System types have special requirements or restrictioN. In this section, the type of syJtem used in the design must be listed and any special restrictions given here referenced to show compliance. Supply references to proper spec:ifi• cationt or drawing page numbers. Type HVAC Syatems Used -List type of system to be used here (inciude all systems for heating or cooling in the building) include reference for specifications for each system. u.Jfirl!:(3. ,S:pu[?(f;' H47±T PUtv1P ( C/£"('/ftllT 1mPRO{/fm1n::IT1 Constant volume reheat system -when serving both intarior and exterior zones -separate cooling coils are required if tht exterior zone exceeds 20% of the total air quantity through the cooling coil. REFERENCE ,...,.,,_, OU.AL DUCT AND MULTIZONE SYSTEMS Constant volume duct or multizone systems which utilize new energy to simultaneously heat and cool air streams which ar• subsequently mixed for temperature control are prohibited for buildings larger than 20,000 square fNt of conditioned space. If used, the air leakage for dampers utilized for the mixing of heating and cooling air shall be limited to a maximum leakage of 3% of the total air quantity handled by the dampers when operating at the maximum system pressure to which the dampers will be subjected. Manufacturer's label or nameplate 5hall state leakage rates. REFERENCE Economizer Cycle -For uch cooling fan system, for other than dual-duct or multizont systems, which 11rv1 zona hiving total cooling capacity greater than 134,000 Btu/hr or more than 5,000 CFM must have an economizer cycle un- i.. one of th, exceptions allowed is claimed. REFERENCE _ _.J./ ..... 1 ,,_/J .... 'A ___ _ Electric Resistance Heating Systems -These systems shall not bt used unless thl tota& 1l1ctric resistance h11ting lnataU1d capacity is less than 10% (ten percent) of the total building space heating capacity or a life cycle cost analysis, Form 8 · (Mt Section 4.2 of this manual) shows an alternate sys.tern life cycle cost exceeds th1t of the electric resistance system. Give reference if less than 10% or include Form 8 if calculating.life cycle cost. · · REFERENCE MECHANICAi,. AND GRAVITY VENTILATION MKh.-.ic:al ventilation -Dampen which are automatically interloclcad and clOMd on fan shutdown are required. REFER~NCE __ t(, ... 1/, __ 4 ______ _ Gravity V1ntilaton -Either automatic or readily acc:essible manually operated dampen must bt provided for Ill open- in111 to the ouuidl with the exception of combustion air openings. POWER CONSUMPTION IN FANS Conltant volume system Total Supply Air Quantity, CFM Taul Prluure of Supply Fans, Inches of Water Totll Supply Air Quantity Adjusted for PrOCIII Loida, CFM REFERENCE _ _.._;V,,_,J')_'/.f ______ _ REFERENCE !'15 O () I 't rorn4 c.C-,,...l • ron-u... S '? F1..oa·~ {I,.(?,~ Net Fan Performance Index (F Pl) Vlrilbll volume system Total supply Air Ouantity at Maximum flow, CPM Total PrlllUrt of Supply Fans 1t Maximum Flow lnch11 of Water . l,, IIOWER CONSUMPTION IN FANS (COll1inutdt Fan ,_,OfflllnCI Index It Maximum Flow (FPlm), CFM Vlrill* Volume Adju1tmtnt Conltant Acquatld for Performance Index, FPl1 PIPING AND DUCT INSULATION AND DUCT CONSTRUCTION ..... , .... o11 e t\l / A; "tftflflCII to tht piping insulation, duct insulation and duct construction requirements pr111nttd in Section 4.2 of 1ht ene,w Conservation Design Manual must be given below: · REFERENCE ____ M ___ -_1 ___ _ DOCUMENTATION FORM & HV.AC EQUIPMENT COMPLIANCE Form6 References giving the specification page or drawing shnt number or manufacturer's data must bt submitted to demonstrate com- pliance with Division 6 of the standlrdl. ELECTRICALLY OPERATED COOLING SYSTEM EQUIPMENT ABSORPTION WATER CHILLING COOLING SYSTEM EQUIPMENT COMBUSTION HEATING EQUIPMENT (Oil and ~firitd comfort heating equipment- ELECTRICALLY OPERATED HEATING HEAT PUMPS ELECTRICAL RESISTANCE SPACE HEATING EQUIPMENT Standard rating c:apac:ity, Btuhtr Minimum EER (COP) Rtfertnc:t Heat source (check one) Direct fired (gas-oil) Indirect fired (steam-hot water) Minimum EER (COP) Reference. Minimum combustion efficiency at maximum rattd outpUt Reference Minimum EER (COP) Reference Supplementary Heater Control Reference REFERENCE FOR FULL-LOAD ENERGY INPUT AND OUTPUT REQUIREMENT FOR MAINTENANCE FOR MANUFACTURER'S MAINTENANCE AND, FULL AND PARTIAL CAPACITY AND STAND-BY INPUT(S) ANO OUTPUT(S) SPECIFICATION REFERENCE t z ( A"f',lll.'-'"4-C~ MF l...B I p &A ~ y\\-/ COMMERCIAL LOAD ESTIMATE FOR .. UNIGLOBE BY WEATHER ENGINEERING INC. 06/02/86 UNIGLOBE 06/02/86 SAN DIEGO *USER SUPPLIED LAT= 33 ALT= 26 CONST= 70W/40R/ 70B ID= 76/50 75 WALL COLOR: MEDIUM ROOF COLOR: MEDIUM SER# 30206831.6 D.B.TEMP TOTAL TONS RSH TONS C.F.M. 1. JUN AT 12 NOON 79.0 2.09 1.74 903 2. DEC AT 12 NOON 71.0 1.72 1.49 775 3. OCT AT 10 A.M. 73.2 1.93 1.65 859 4. NOV AT 2 P.M. 77.0 2.28 1.97 1,025 s. SEP AT 3 P·.M. 83.0 3.06 2.67 1,388 6. JUL AT 4 P.M. 84.0 3.43 3.00 1,558 7. JUN AT 4 P.M. 83.0 3.38 2.95 1,534 ZONE HEATING-->= 8,347 W/INFIL= 8,347 C.F.M = 217 TRANSMISSION FACT. TEMP DIFF HEATING TEMP DIFF COOLING FLOURESCENT LIGHTS INPUTS CEILING PARTITION o.oo 0.08 0 30 0 20 Y SOLAR FACTOR FLOOR 0.00 0 0 SKYLIGHT= EFFECTIVE AVERAGES FOR ZONE LOADS·OR OP-COST SKYLIGHT 0.00 40 8 o.oo EiPOSURE: N. NE E. SE S •.. SW W. NW WALL TRANS. FACTORS 0.00 0.00 0.00 0.00 0.00 0.00 0.08 0.00 GLASS TRANS FACTORS 0.00 0.00 0.00 o.oo ·o.oo o.oo 1.13 ·o.oo GLASS SOLAR FACTORS 0.00 0.00 0.00 0.00 0.00 0.00 0.75 0.00 ROOF TRANS. FACTOR = 0.08 SKYLIGHT TRANS. FACTOR= 0.00 OUTPUTS NUMBER OF PEOPLE = 11 SENSIBLE PEOPLE LOAD = 2,639 TOTAL LIGHTS = 2,693 LIGHTING LOAD = 11,487 OTHER ELECTRICAL = 539 OTHER ELECTRICAL = 1,838 w. TYPE 1 GLASS AREA= 156 w. TYPE 1 GLASS SOLAR = 17,957 TOTAL GLASS AREA = 156 TOTAL GLASS SOLAR = 17,957 TOTAL GLASS AREA = 156 TOTAL GLASS TRANS. = 1,410 SKYLIGHT AREA = 0 TOTAL SKYLIGHT SOLAR = 0 SKYLIGHT AREA = 0 TOTAL SKYLIGHT TRANS = 0 w. TYPE 1 WALL AREA= 150 w-. TYPE 1 WALL LOAD = 209 TOTAL WALL AREA = 150 TOT AL WALL TRANS . = 209 PARTITION AREA = 284 TOTAL PART. TRANS = 454 CEILING AREA = 0 TOTAL CEILING TRANS = 0 FLOOR AREA = 0 TOTAL FLOOR TRANS = 0 AREA OF ROOF = 0 ROOF LOAD = 0 UNIGLOBE SAFETY FACTOR = EVAP FAN H.P. = MISC SENSIBLE = VENTILATION CFM = MISC. LATENT = NUMBER OF PEOPLE= VENTILATION CFM = TOTAL CFM-STD AIR= 0% 0.45 0 81 0 11 81 1,558 SAFETY B.T.U.S FAN HEAT GAIN -DT MISC. SENSIBLE O. A.SENSIBLE LOAD MISC. LATENT PEOPLE LATENT LOAD O.A. LATENT LOAD TOTAL LATENT LOAD ROOM SENSIBLE = 35,994 ROOM LAT. LOAD ********************************************** UNIGLOBE = 0 = 1,368 = 0 = 711 = 0 = 2,208 = 829 = 3,037 = 2,208 --> GRAND TOTAL LOAD= 41,110 BTU'S OR 3.43 TONS<-- LOAD RUN FOR # 6. JUL AT 4 P.M. AREA (SQ FT) = 1,077 SQ. FT PER TON = TOTAL CFM-STD AIR = 1,558 CFM PER SQ FT = HEATING LOAD PARTITION LOAD = 682 CEILING LOAD = ·VENTILATION LOAD = 3;554 ROOF HEATING LOAD·= FLOOR HEATING LOAD= 0 SKYLIGHT LOAD =· GLASS HEATING LOAD= 7,051 WALL HEATING LOAD = SLAB HEATING LOAD= 135 INFIL HEAT LOAD = WARM UP LOAD = 0 H LOAD WITH VENT = COIL SELECTION PARAMETERS DB TEMP ENT/LVG = 76.4 / 54.2 TOT SENSIBLE LOAD = WB TEMP ENT/LVG = 62.7 / 53.6 TOTAL COIL-LOAD = SPECIFIED ROOM RH = 50% RESULTING ROOM RH = TERM AIR TEMP = 55.00 ·; 110 DEGREES ROTATED= 0 T. ST. EVAP FAN= 1.00 NON-CEILING RETURN BLDG. 'U' FACTOR= 0.62 STAPLES DEFAULTS 314 1.45 0 0 0 480 0 11,902 38,073 41,110 46% POOR QUALITY · ORIGINAL S I ,, l ·t ·.l ' • . Climate Master 803/804 VERTICAL HORIZONTAL SERIES WATER-TO-AIR HEAT PUMPS ~ t;t£,Jiffih Climate Master~ ' I' l ?, l r ~ 1 I• ~ ! 803·804 SERIES PERFORMANCE DATA AT ARI RATING CONDITIONS (ARI STD. 320-81) Coolin~ Heating Mudtl Sen· Puwc1 HH Ht:Jt ul Wdlcr Atr j'jd Powur Heat of Wator Atr hel ,101~ Reiect Input COP Absorp. Num~cr' • iHUti Input Halrng GPM CFM ilTUH GPM CFM llTUH w~11~ llTUH watts BTUH 803-009 9100· 6461 825 11.0 11915 2.4 350 1oaoo· 850 3.7 7900 2.4 350 804-009 803-012 12500 8625 1225 10.2 16680 3.34 400 15700 1325 3.5 11179 3.34 400 804-012 803-015 14500 10295 1400 10.4 19300 3.90 500 19000 1525 3.7 13800 3.90 500 804-015 803-019 19000 13870 1750 10.9 25000 5.0 650 23000 1875 3.6 16600 5.0 650 804-019 803-024 25400 17580 2275 11.2 33162 6.6 BOO 35000 2650 3.9 25960 6.6 800 804-025 803-030 30000 21860 2900 10.3 39900 8.0 1000 40500 3200 3.7 29580 8.0 1000 804-031 803-036 35600 24400 3360 10.6 47064 9.4 1250 42500 3550 3.5 30400 9.4 1250 804-037 803-042 43000 32170 4000 10.8 56652 11.3 1500 57000 4200 4.0 40665 11.3 1500 -·--;,-804-043 42000 31400 4050 10.4 55819 11.2 1450 57000 4450 3.8 41987 11.2 1450 803-048 48000 37250 4750 10.1 64212 12.8 1700 59000 4650 3.7 43130 12.8 1700 804-048 803-060 62000 46800 6100 10.2 82819 16.6 2000 68000 5600 3.6 48892 16.6 2000 804-060 804-096 96000 74950 9400 10.2 128082 25.6 3400 112000 9100 3.6 80950 25.6 3400 804-120 124000 93550 12200 10 2 165639 33 1 4000 137000 11500 3 5 97762 33.1 4000 ·For Units operating at 208V. deduct 200 BTUH from capacity ratings (009 Models only). · • Cooling only: Units available 903 904 · J Gf.NFRAL DATA CHART l'llutlel Mlll Mrn CRC MdX. Cumµ Curnµ Bluwcr Total t!IUwcr 61uwer lllower Rel. to Coil Fin~ lllowor Shtpprny Nu111oe1 llultdye I'll Wuc Alllµ· tu:.c LliA HLA fLA FLA WIii Uid Will. Lth. HP Air Fact: Oopth •In. Type Wt. Lbs. ,ICII\ Area '803-009 208 230 1 #14 4.6 15 20.0 3.3 .50 3.8 5.5 5.0 1/20 .97 3.00 14 DDMS 118 804-009 265 1 #14 4.0 15 16.0 2.8 .50 3.3 108 803-012 208i230 1 #14 8.7 15 31.0 6.3 .80 7.1 6.0 4.0, 1i10 .97 3.75 14 DDMS 123 804-012 265 1 #14 6.9 15 27.0 4.9 .81 5.71 117 803-015 208'230 '1 #14 8.25 15 36.0 5.9 .86 6.76 6.0 5.0 1/12 2.22 2.25 14 DDMS 150 804-015 265 1 #14 7.35 15 33.0 5.0 .82 5.82 153 803-019 208,230 1 #14 11.1 15 40.6 7.6 1.5 9.1 9.0 4.0 116 2.22 3.0 14 DDMS 173 804-019 265 · 1 #14 8 7 lS 34.0 6.0 1.2 7 2 180 803-024 208,230 1 #10 16.4 25 54.0 11.8 1 6 13.4 9.0 7.0 1/4 2.50 2.25 13 DDMS 210 804-025 265 1 #12 14.4 20 45 0 93 1 5 10.8 213 2081230 1 #10 19.5 30 65.0 14.0 2.0 16.0 803-030 2081230 3 #12 13.9 20 60.0 9.2 2.0 11.2 10.0 6.0 1/4 2.50 3.0 13 DDMS 225 804-031 265 1 #10 17.2 25 55.0 11.2 1.6 12.8 460 3 #14 6.5 15 28.0 4.4 1.0 5.4 208/230 1 # 8 23.0 35 75.8 15.8 3.2 19.0 803-036 2081230 3 #10 16.7 25 65.0 10.4 3.2 13.6 9.0 7.0 1/2 3.33 2.25 14 DDMS 248 804-037 265 1 # 8 21.6 35 70.0 13.5 3.2 16. 7 235" 460 3 #14 8.3 15 32.0 5.2 1.8 7.0 803-042 208,230 1 # 8 28.7 45 93.0 19.4 3.4 22.8 10.0 8.0 3.00 278 208;230 3 #10 19.4 30 74.0 12.5 3.4 15.9 1/2 3.33 14 DDMS 804-043 460 3 #14 9.6 15 41.0 6.3 1.8 8.1 9.0 7.0 2.25 240 803-048 208/230 1 # 8 30.0 45 104.0 19.8 5.4 25.2 312 804-048 208/230 3 # 8 23.0 35 72.0 14.1 5.4 19.5 10.0 10.0 314 4.17 3.25 14 DDMS 300 460 3 #14 11.0 15 35.0 7 0 2.2 9.2 803-060 208;230 1 # 8 39.8 60 132.0 26.0 5.8 31.8 339 804-060 2081230 3 # 8 26.4 40 103.0 16.1 5.8 21.9 12.0 10.0 1 4.17 4.33 13 DDMS 357 460 3 #12 12.5 20 54.0 7.9 2.6 10.5 804-096 208:230 3 # 6 37.4 50 72.0 14.1 5.7 33.9 (2) (2) 460 3 #10 18.4 25 35.0 7 0 2.6 16.6 10.0 10.0 1-112 8.33 3.25 14 BDVP 680 _ __) 804-120 2081230 3 # 4 44.6 60 103.0 16.1 7.5 39.7 (2) (2) 460 3 #10 21 2 25 54 0 7 9 3 4 19.2 12 0 10 0 2 8.33 4.33 13 BOVP 800 . 2 '• I J .J \, ..... ) I :111, lf"lt. l'I i!l llllM,\NI I I ,\J, : 11111 IN!. l'I Ill llHM/\Nt'I 111111 I ,_) W.tlt!r LUI W,tl Luu11n4 'Hal th:,11 ul h .... 1 l 1 .1.,11 .. u: ,~.11 'h ,llllllj lit',1I ul l'll'Wl"I 1 l!d'IIIIII l'U fluw Ttmµ (111.11 .•hll· lh:11::1'1 11,t, .. : W,11 lt::111~ l1•111i1 1,,1,11 Ah\,HIJ IIIIJUI W•I Temp f-1 ul u~M r 1111111 UHIII UTIIII .V.:d' I f 11IUH ttllJH W,t!h •f WJler 5.00 65' 42500 31400 55640 3850 87 3 60" 46500 33019 3950 468 4.0 800 65" 43000 31000 55457 3650 78 9 60' 50000 35836 4150 51 0 94 11.00 65' 43000 30800 55116 3550 750 60' 51500 37165 4200 53 2 166 14.00 65' 43000 30600 54946 3500 728 60' 52500 37995 4250 54 6 256 5.00 75' 42000 31400 55993 4100 97 4 65' 50000 35836 4150 50.7 40 8.00 75• 42500 31400 55811 3900 890 65" 53000 38495 4250 55.4 9.4 11.00 75' 43000 31200 '55969 3800 85 2 65' 54500 39653 4350 57 8 16.6 14.00 75' 43000 31200 55799 3750 830 65" 55000 40153 4350 59.3 25.6 5.00 es· 40500 31200 55347 4350 107 1 70' 53500 38824 4300 54 5 40 6.00 85' 41500 31400 5566-4 4150 98.9 70' 56000 40983 4400 59.8 9.4 11.00 65' 42000 31400 55823 4050 95.1 70' 57000 41812 4450 62 4 16.6 14.00 85' 42000 31400 55652 4000 93.0 70' 57500 42142 4500 64.0 256 5.00 90• 39500 30800 54688 4450 111 9 80' 58500 43142 4500 62.7 40 8.00 90' 41000 31200 55505 4250 103.9 80' 60000 44300 4600 68 9 9.4 11.00 90' 41500 31400 5566-4 4150 100.1 80' 61000 45300 4600 71.8 166 14.00 90' 41500 31400 55493 4100 979 80' 61500 45630 4650 73.5 25.6 5.00 95' 38500 30400 54200 4600 116 7 90' 62000 46130 4650 71.5 40 8.00 95' 40000 31000 55017 4400 1086 90' 63500 47459 4700 78.1 94 11.00 95• 41000 31200 55676 4300 1051 90' 64000 47788 4750 81 3 166 14.00 95' 41000 31200 55505 4250 102.9 90• 64500 48288 4750 831 256 f'UIHlrCl ION FACT!lHS Ffill VAHIATION IN FN 1 ffllNfi lilR TFMPFRATUHF lnl lulJI :,i.11,1b1t· l.dp,tt.1ly t nllfllllj i\11 I.Ji-. hu,i1 Jh,11 i'Uwl'I lnl 11,1.,1 Hi:JI Pow tr Au l,0011114 Ill l111,1ul Au tltJllfltl ul lnpu1 f WU t:.1 IJCII)' /U uu /~ 118 IIU UH H~ lJH "" uu HL1C..l..i ., uu C.tµ,1c1ly Ab;uib 61' 0.860 0.871 1.086 1.302 1 517 1.732 0890 0981 60' 1.004 1.022 0.953 64' 0.937 0.719 0.935 1.150 1 365 1580 0.950 0991 65' 1.002 1.011 0.976 67' 1.000 0.570 0.785 1.000 1 215 1.430 1 000 1 000 70' 1 000 1.000 1.000 70' 1.050 0.637 0.852 1 067 1 262 1.040 1 009 75' 0.999 0.990 1.024 73' 1 087 0.490 0.706 0.921 1136 1 070 1 019 80' 0998 0.980 1.048 COAHfCTION FACTORS FOR VAHIATION IN AIR FLOW Air How IUldl C.,n1llng S1:11MlJIC lh·,11 111 Pi, .. t:I Tu1.,1 llt;,11111(1 llc,tl ol Power t:fM CJu,u.1tv L,1U,u.1h Hn1d 11111111 L.aih1t.1ly AIJ~uru lnpul 1075 0.964 0.920 0963 0.959 0969 0.955 1 005 1200 0.976 0.947 0.975 0972 0.979 0970 1.003 1325 0.968 0.973 0.988 0.986 0990 0.985 1.002 1450 1.000 1.000 1.000 1.000 1 000 1.000 1 000 1575 1.012 1.027 1.012 1.014 1.010 1.015 0998 1700 1.024 1 053 1 025 1 028 1.021 1 029 0.997 J 803-048 804-048 i'lllH INC l'i Ht OHM/\Nf'l· 11\Hl I 111.AflN(i f'FH~ORMANCE TAHL[ WJlt:t lnl Wdl l.11llll114 :,r11 11t:,II u/ t'11w,, J l'JWlllll lui W,,t 111,,111114 t11•dl ul t'uwct I CdVIIUj PD How lump 1111.11 ,,111c lh:11:11 1111ml W,11 lcmi> h:111µ lt1l,1i ACJ~urp l11µul Wal Jump 11 ul GPM 'f llllJ11 II 1IJ11 UIUlt 'h,111\ f I lllU~ HIUII WJII~ "f W•ler 6.00 65' 49000 37200 64359 450() 86.5 60' 48500 34165 4200 48.6 4.2 925 65' 49000 36800 63676 4300 78.8 60' 52000 37153 4350 52.0 9.3 12.50 65' 49500 36600 63835 4200 752 60'. 53500 38483 4400 53.8 15.9 15.75 65' 49500 36400 63493 4100 73.1 60' 54000 38812 4450 55.1 24 1 6.00 75' 48000 37200 64382 4800 96.5 65' 52000 37153 4350 52.6 4.2 9.25 75' 48500 37200 64029 4550 888 65' 55000 39812 4450 56.4 93 12.50 75' 49000 37000 64188 4450 65.3 65' 56000 40471 4550 58.5 15.9 15.75 75' 49000 37000 64017 4400 831 65' 57000 41471 4550 59.7 24.1 6.00 85' 46500 37000 63906 5100 1063 70' 55500 40142 4500 56.6 42 9.25 85' 47500 37200 64053 4850 98.8 70' 58000 42300 4600 60.9 9.3 12.50 85' 48000 37200 64212 4750 953 70' 59000 43130 4650 63.1 159 15.75 85' 48000 37200 64041 4700 931 70' 59500 43459 4700 64 5 24.1 6.00 90' 45500 36600 63248 5200 1111 80' 60500 44459 4700 65.2 42 9.25 90' 47000 37000 64065 5000 103.9 80' 62500 46118 4800 70.0 9.3 12.50 90' 47500 37200 64224 4900 1003 80' 63000 46447 4850 72.6 159 15.75 90' 47500 37200 64053 4850 98.1 80' 63500 46947 4850 740 24 1 6.00 95• 44500 36200 62930 5400 116.0 90' 64500 47776 4900 74.1 4.2 9.25 95• 46000 36800 63406 5100 108 7 90' 66000 49106 4950 794 9.3 12.50 95• '46500 37000 63565 5000 1052 90' 66000 49106 4950 82.1 15.9 15.75 95' 47000 37000 64065 5000 1031 90' 67000 50106 4950 836 241 l'llHllll'llllN f/\l'IIIH', 1!111 IJ!\hl/\llllN IN lt.lll!ltH, /\IH It Ml'l ll/lllllH lilt lut,11 : t!ll:-.1illl' t,.J._iJ,.,11 f I lolt'I 111,j A.1 111111.,:, flt,1[ l•,,..,.t:I I 11l h.11.ll Ht:111 Powt1 Air Cuuh111J "' luµul Au Hi;Jlllltl ul lnpul "f WB Cdl1o1LIIV Ill 1111 ,:, IIIJ nu lJb 0,J lllJ !Ju Ub 1,1 \\.: I IJU l.,IVJLlt'j' Ab;urU 61' 0.896 0.871 1 086 1.302 1.517 1 732 0.907 0.937 60' 1001 1.019 0.954 64' 0.951 0.719 0.935 1.150 1 365 1.580 0.955 0969 65' 1 001 1.009 0.977 67' 1.000 0.570 0.785 1.000 1.215 U30 1.000 1 000 70' 1.000 1.000 1.000 70' 1.043 0.637 0.852 1.067 1.282 1.040 1.031 75' 1.000 0.991 1 023 73" 1.081 0490 0 706 0.921 1136 1.076 1 063 80' 1.000 0.982 1 047 l'OIHH1.'!1(1N ~Al'lllfl'. I OH VAHIA I Ill/II l~i /\Ill 11 OW Au tluw lul,11 Lu111nllJ ,1:11:.101t· ,l,,1 >i 1,!l'tl I l,1:,11 ,11,111111.1 t1c11t ul l'uwer CIM l,JIJ,llllt l.,Jµ,h,11• h, •• ..I ... , .. ,i l.Jµ,11..,1, AU:,ttfU lupul 1250 0.963 0918 0962 0.958 0.945 0932 0981 1'400 0.975 0945 0.974 0.972 0963 0.954 0988 1550 0.988 0973 0987 0986 0981 0.977 0.994 1700 1.000 1 000 1 000 1 000 1 000 1 000 1 000 1850 1.012 1.027 1 013 101• 1.019 1 023 1 006 2000 1.025 1.055 1 026 1 028 1 037 1.047 1 012 Based upon ARI Standard 320-61. 8 r--Left Hand Return -End Blow E NOTE: All side panels are removable. Return Air Collar l,I 1 Kl ® ® Right Hand Return -End Blow r NOTE: All side panels are removable. i -C BSP D J r 1 CSP CAP l_J \____ MSP-__; ,© r .,, BSP l C D r l CSP CAP l j L__MSP-__j 0 E 0---,jT~l-/ _ _j__ 2''J I ----------- ® ® Discharge Air Collar "(10'',H x 9''7W) , J ,L r~ Condenute lnpplng: Differential Trapping Required. Fitter Sin: 025 and 031 Models: 18 x 22V, x 1· (1 Req.) 037 and 043 Models: 20 x 25 x 1· (1 Req.) Fitter AcCH1: Left and Right on Inlet By Removing Side Clip. ® ® -¥, FPT -Supply & Return Water Connections © -¥• FPT-Condensate Connection ® -HI Voltage-1¼-'II-Combination Knockout (Optional Location On Side) ©-Lo Voltage-½ Dia. 0251031 A 19 B 43 C 2H'4 0 H'4 E 2% F 11/1s G 51/e H H'4 I 41/e J 16¼H K 20½W ·Q31-11½H x 8½W 025/031- A 43 B 19 C 2H'4 0 ' 1¾ E 11/s F 51/s G 11/,5 H 2% I 41/e J 1¾ K 16¼H l 20½W '031-11 1/zH x 8½W Return Air Collar -·----· fK-.. U 0371043 21 47 21½ 1½ 4 21'16 5 2¼ 51/4 18¼H 23W 037/043 47 21 21½ 1½ . 1¼ 5 21/1s 4 5¼ 2¼ 18¼H 23W M ~ 0 -r,.. M 0 -,... M 0 -Lt) N 0 ~ 0 C0 17 ·-With wet coil and clean filter l:3LOW!:.H PEHF-"OHM/\NCE:. CHJ\H I Model Fan Cf Mal Lxlr.rnal :,1,111r l'tr~,111': I W Ii Minimum Numbers Speed 0.1 0.2 0.3 0.4 0.5 0 6 0.7 0.8 O.!I CFM 803-009 High 356 332 306 254 804-009 Medium 330 306 280 250 240 Low 300 280 260 240 803-012 High 450 410 406 384 360 804-012 Medium 430 412 392 372 350 325 320 Low 410 395 378 356 334 320 803-015 High 560 545 528 507 486 804-015 Medium 540 528 510 492 473 460 Low 516 507 493 478 460 Hi h 800 760 715 665 600 803-019 M~um 700 675 635 600 550 520 804-019 Low 650 625 600 560 520 803-024 High 1150 1070 970 895 780 804-025 Medium 1020 945 860 775 730 620 Low 890 825 760 690 620 803-030 High 1165 1100 1035 955 880 804-031 Medium 1110 1055 990 930 865 805 800 Low 1020 965 910 850 803-036 High 1500 1420 1340 1250 1170 1080 804-037 Medium 1360 1310 1250 1190 1110 1000 1000 Low 1290 1240 1190 1120 1030 High 1780. 1700 · 1620 1540 1440 1340 803-042 Medium 1610 1610 1540 1460 1370 1260 1200 · Low 1540 1500 1450 1400 1330 High 1620 1545 1465 1375 1275 804-043 Medium 1475 1415 1340 1270 1190 1150 Low 1385 1335 1275 1205 803-048 High 2130 2050 1960 1860 1750 1630 804-048 Medium 1980 1900 1810 1720 1620 1520 1400 Low 1810 1730 1650 1570 1490 1400 803-060 High 2200 2140 2080 2010 1940 1860 804-060 Medium 2110 2050 2000 1940 1870. 1800 1700 Low 2060 2000 1940 1880 1820 1760 1700 Closed 4200 4040 3880 3700 3500 3270 3040 1 Tum 4150 4000 3840 3650 3450 3220 2980 804-096 2Tums 4100 3960 3800 3600 3400 3200 2940 3Tums 3940 3770 3580 3380 3140 2890 2800 4Tums 3760 3590 3370 3090 2800 5Tums 3540 3340 3090 2800 Closed 4400 4230 4035 3850 3660 1 Tum 4360 4160 3990 3830 3680 804-120 2Tums 4240 4060 3900 3740 3590 3400 3Tums 4190 4010 3860 3710 3560 3400 4Tums 4150 3980 3820 3670 3520 5Tums 3920 3770 3610 3400 CAUTION: Lim! should not be operated at CFM below minimum specified above 208 VOLT CFM CORRECTION FACTORS FOR THE FOLLOWING MODELS ONLY Model Numbers High Speed Medium Speed Low Speed 803-009/804-009 -.931 .914 .892 803-024/804-025 .958 .899 .854 803-036/804-037 .965 .935 .905 803-042 .984 .935 .886 804-043 .971 .937 .927 803-048/804-048 .95 .930 .912 803-060/ 804-060 .95 .930 .912 Units should not be operated below minimum CFM in Blower Performance Chart. Air flow data is based on rated voltage and the most restrictive unit arr flow arrangement. Duct system design should allow balancing for actual job requirements. 11