HomeMy WebLinkAbout2386 Faraday Ave; 125; CBC2018-0551; Permit(City of
Carlsbad
Commercial Permit
Print Date: 02/11/2019
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
Description:
2386 Faraday Ave, 125
BLDG-Commercial
2120621700
$230,317.52
SPEC SUITE: 4,952 SF T.I.
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Work Class:
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check #:
Plan Check#:
Owner:
RR E F !I ONE RESEARCH LLC
2382 Faraday Ave, 250
CARLSBAO, CA 92008
ELECTRICAL BLDG COMMERCIAL NEW/ADDITlON/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
$B1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $2,248.28 Total Payments To Date:
Tenant Improvement
$2,248.28
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Permit No: CBC2018-0551
Closed -Finaled
10/02/2018
11/16/2018
CRenf
2/11/2019 9:31:00AM
$0.00
$1,091.05
$763.74
$89.00
$17S.DO
$55.00
$10.00
$64.49
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
,,
C6~aJ8-
.
Plan Check N~ «1~ Building Permit Application Est. Value .:$,;) 36,2>17. '," .,:Z ~ CITY
1635 Faraday Ave., Carlsbad, CA 92008
OF 760-602-2717 / 2718 / 2719 Plan Ck. Deposit :ti ~ ,. 7'-1 CARLSBAD Fax 760-602-8558 --
www.carlsbadca.gov Date /()/~It y I ,
JOB ADDRESS 2386 Faraday Avenue
SUITEf/SPACEf/UNIT•
( 125 l \"" 212 -062 -17 -00
0f~2. ~ \[;:~ \1 I PHASE# l#OF~ITS l#BEDR;MS # BATHROOMS ITEN USIN AME ICONSTR.TYPE I DCC.GROUP
0 Speciiiative Suite (No Tenant) VB B
DESCRIPTION OF WORK: Include Square Feet of Atrected Area(S)
Tenant Improvement to include new interior partitions, electrical, mechanical and plumbing. 4,952 S.F~ -L/'?o~ SF -
EXISTING USE I PROPOSED USE I GJ'l..RAG~ (SF) PATIOS (SF) I DECKS {SF) I FIREPLA(.:lc 1 IAIR CONDITIONING ~FIRE SPRINKLERS
Office Office 0 0 YES0, No[Z] YES[{]No□ YES[{]No□
CONTACT NAME (ff Different Fom App/leant) APPLICANT NAME RBN Design
ADDRESS ADDRESS 5090 Shoreham Place
Cl1Y STATE ZIP Cl1Y STATE ZIP
San Diego CA 92122
PHONE IFAX PHONE IFAX 619-297-1011
EMAIL EMAIL Lrocha@RBN-Design.com
PROPERTY OWNER NAME CONTRACTOR BUS. NAME Bvcor General Contractors
ADDRESS ADDRESS 6490 Marindustry Dr. #A
Cl1Y STATE ZIP Cl1Y STATE ZIP
San Dieao CA 92121-2563
PHONE IFAX PHONE
858-587-7462 IFAX 858-210-3949
EMAIL EMAIL andrew.mendoza@barneyandbamey.com
ARCH/DESIGNER NAME & ADDRESS I STATE UC. II STATE LIC.# l"ASS B I CITY BUS. LIC.#653400 444203
(Sec. 7031.5 Business and P_rofessIons Code: Any City or Coun_ty which requires a permit to_construct, alter, improve, demolish or repair an)'. structure, prior to its issuance, also requires the appl!cant for such per_mIt to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law )Chapter 9, commending with Section 70_00 of Division 3 of the B_usiness and Professions Code} or [hat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 031.5 by any applicant for a permit subJects the applicant to a
civil penalty of not more than five hundred dollars {$500}).
WORl<ERS' COMPENSATION
Workers' Compensation Declaration: / hereby affirm under penalty of pelju,y one of the following declarations:
B l have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for wtiich this permit ls issued,
I have and will maintain workers' compensation, as reQUired by Section 3700 of the LaOOr Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co Manih & Mclennan Agency LLC -----Policy No. WSD503018003 Expiration Date OMJ1f1t
~section need not be completed if the permit is foro e hundred dollars ($100) or less LJ Certificate of Exemption: I certify that in the rmance of the work for which this pennit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California WARNING: Failure to secure wo 'compensati n rage i nlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, da a as provided ctlon of the Labor code, Interest and attomey's fees.
RS CONTRACTORSIGNATURE lliill,._..,c..,~ '?...
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
□
□
□
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who buikfs or improves thereon, and who does rk himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the o Ider will have the burden of proving that he did not buik:I or improve for the purpose of sale)
I, as owner of the property, am exclusively contracUng with licensed contracto nstruct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such proj oontractor(s) licensed pursuant to the Contractor's License Law),
I am exempt under Section ____ Business and ions Code for tl11s reason-
1. I personally plan to provide the major labor a aterials for construction of the proposed property improvement. OYes ONo
2. I (have I have not) signed an applk:af or a building permit for the proposed work
3. I have contracted with the fol g person {firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portio the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number):
5. I will provide som the work, but I have contracted {hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work)·
RS PROPERTY OWNER SIGNATURE □AGENT DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building oco..ipant required to submit a business a, acutely hazardous materials registration fonn or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substar.ce Account Act? 0 Yes LL,JNo
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or a~ality management district? Des CZ] No
Is the facility to be constructed within 1,000 feet of the outer boon day of a school site? 0Yes lLJNo
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
APPLICANT CERTIFICATION
I ceitifythat I have read the application and state that the above infonnation Is correct and that the infonnation on the plans is accurate. I awee to comply with all City ordinances and State laws relating to building construclion.
I hereby authOOZe representative of the City of Carlsba:l to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND XPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA pennlt is required for excavatklns o deep i3"ld demolrtion or construction of structures over 3 stories in height.
EXPIRATION: Every pennit issued by the Buildirg al under the provisions is Code shall expire by !imijalion and become null and VJid if the building or \\Qrk authorized by such pennrt is not oommenced within
180 days from the date of such pennlt or ithe bui or work authorlzed b c pennlt · suspended or abandoned at any time after the work is oommenced for a period of 180 ays (Section 106.4.4 Uniform Building Code)
,85 APPLICANT'S SIGNATURE DATE
PERMIT INSPECTION HISTORY REPORT (CBC2018-0551)
Permit Type: BLDG-Commercial Application Date: 10/02/2018 Owner: RR E F II ONE RESEARCH LLC
Work Class: Tenant Improvement Issue Date: 11/16/2018 Subdivision: PARCEL MAP NO 16317
Status· Closed -Finaled Expiration Date: 07/16/2019 Address: 2386 Faraday Ave, 125
Cansbad, CA 92008-7222
IVR Number: 14334
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
12/0612018 12/06/2018 BLDG-84 Rough 078072-2018 Partial Pass Chris Renfro Relnspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Rough combo on walls only. HVAC and Yes
mechanical pending.
BLDG-14 Yes
Frame-.Steel-Bolting-We\ding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts,.Dampers
12/12/2018 12/12/2018 BLDG-17 Interior 078616-2018 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Walls not, Rm 101-111 Yes
12/1812018 12/18/2018 BLDG-44 079169-2018 Passed Chris Renfro Complete
Rough/Ducts/Dampe
rs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/17/2019 01/17/2019 BLDG-86 T-Bar, 081627-2019 Passed Chris Renfro Complete
Ceiling Grids,
Overhead
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Add clips to T-grid in areas pointed out; add Yes
fire caulk to penetrations, ok to lay ceiling
tile
BLOG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
02/11/2019 02/11/2019 BLDG-Final 083472-2019 Passed Chris Renfro Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Fina\ Yes
February 11, 2019 Page 1 of 1
DATE: 11/13/2018
JURISDICTION: Carlsbad
PLAN CHECK#.: CBC2018-0551
✓• EsG1I
SET: II
PROJECT ADDRESS: 2386 Faraday Ave. #125
PROJECT NAME: Spec Suite Tenant Improvement
□ APPLICANT
□ JURIS.
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted:
Mail Telephone
0 REMARKS:
By: Jason Pasiut
EsGil
(by:
Telephone#:
) Email:
Fax In Person
Enclosures:
11/5/2018
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 10/11/2018
JURISDICTION: Carlsbad
PLAN CHECK#.: CBC2018-0551
✓• EsG1I
A Sf\FFb~ill Currp,my
SET: I
PROJECT ADDRESS: 2386 Faraday Ave. #125
PROJECT NAME: Spec Suite Tenant Improvement
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Laura Rocha
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: L ura Rocha Telephone#: 619-297-1011
U (b4V ) Email: lrocha@rbn-design.com
By: Jason Pasiut
EsGil
In Person
10/4/2018
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBC2018-0551
10/11/2018
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK#.: CBC2018-0551
OCCUPANCY: B
TYPE OF CONSTRUCTION: V-B
ALLOWABLE FLOOR AREA: within
SPRINKLERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 10/2/2018
DATE INITIAL PLAN REVIEW
COMPLETED: 10/11/2018
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
USE: Office
ACTUAL AREA: 4,952sf
STORIES: 3
HEIGHT: unchanged
OCCUPANT LOAD: 127
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 10/4/2018
PLAN REVIEWER: Jason Pasiut
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CBC2018-0551
10/11/2018
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and
Fire Departments.
2. Bring DtiQ corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
• PLANS
1. Show that compliant restrooms are marked with signs per 11 B-703. 7.2.6.3,
including braille and the International symbol of accessibility. 11 B-216.8.
a) AB1732 Section 1, Article 5: 118600:
All single-user toilet facilities in any business establishment, place of
public accommodation, or state or local government agency shall be
identified as all-gender toilet facilities by signage that complies with Title
24 of the California Code of Regulations and designated for use by no
more than one occupant at a time or for family or assisted use.
b) The location of and directions to the compliant restrooms shall be posted in
or near the building entrance and shall include the International symbol of
accessibility. 11 B-216.8.
2. Note on the plans that newly installed receptacles will be within the reach ranges
of 11 B-308.
• MECHANICAL/ ELECTRICAL/ PLUMBING
3. Describe the method of compliance for temperature limitations for the following
fixture types: private lavatories (120 degrees), public use lavatories and bidets,
(limited to 110 degrees) and (bathtubs and showers (120 degrees)). Note: The
water heater thermostat may not be used for compliance with this Code section.
CPC 408.3, 409.4, 410.3, 421.2, and Energy Standards 11 0(C)3.
Carlsbad CBC2018-0551
10/11/2018
4. Provide a detail for the condensate drain showing adequate fall, sized per CMC
Table 310.3, trap, vent, cleanout, and draining into an indirect waste receptor or
lavatory tail piece within the same space being conditioned. CMC 31 0.
• END OF REVIEW
To speed up the review process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number, calculation
page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list. If there are other changes. please briefly describe them
and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate: □ Yes □ No
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review
items, please contact Jason Pasiut at Esgil. Thank you.
Carlsbad CBC2018-0551
10/11/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Jason Pasiut
PLAN CHECK#.: CBC2018-0551
DATE: 10/11/2018
BUILDING ADDRESS: 2386 Faraday Ave. #125
BUILDING OCCUPANCY: B
BUILDING AREA Valuation Reg.
PORTION ( Sq. Ft.) Multiplier Mod.
4952 46.51
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1997 UBC Buildin Permit Fee g ' ....
1997 UBC Plan Check Fee • I
I 'hi ~~I:
Type of Review: Complete Review
VALUE
D Structural Only
D Repetitive Fee
...,. Repeats
D Other
□ Hourly
&Gil Fee f---------11 Hr. @ •
Comments:
($)
230,318
230,318
$665,581
Sheet 1 of 1
SAN DIEGO REGIONAL
HAZARDOUS MATERIALS QUESTIONNAIRE
. ---··--------.~~---------
OFFICE USE ONLY
UPFP# ______ _
HV# _______ _
BP DATE._~-~---
Business Name Speculative Suite 125 Business Contact Laura Rocha ;"lephone t 619-297-1011
Project Address City State Zip Code APN# 2386 Faraday Avenue Carlsbad CA 92008 212-062-17-00
Mailing Address City State Zip Code Plan File#
Project Contact Laura Rocha Telephone#
I \ 619-297-1011
The following questions represent the facility s activities, NOT the specific project description.
PART I: FIRE DEPARTMENT-HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business
will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency INith
jurisdiction prior to plan submittal.
1. Explosive or Blasting Agents
2. Compressed Gases
3. Flammable/Combustible Liquids
4. Flammable Solids
5. Organic Peroxides
6. Oxidizers
7. Pyrophorics
8. Unstable Reactives
9. Water Reactives
1 O. Cryogenics
11. Highly Toxic or Toxic Materials
12. Radio8ctives
13. Corrosives
14. Other Health Hazards
15. NoneofThese.
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3 ° floor, San Diego, CA 92101.
Call (619) 338-2222 prior to the issuance of a building permit
FEES ARE REQUIRED. Expected Date of Occupancy: -----'/'-----'/ __ _
YES NO
1. □ Jl'1
~• B I
4.
5.
6.
□ □ □ !
Is your business listed on the reverse side of this form? (check all that apply).
Will your business dispose of Hazardous Substances or Medical Waste in any amount?
Will your business store or handle Hazardous Substances in quantities equal to or greater than
55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity?
Will your business use an existing or install an underground storage tank?
Will your business store or handle Regulated Substances (CalARP)?
Will your business use or install a Hazardous Waste Tank System (Title 22, Article 1 O)?
0 CalARP Exempt
I
Date Initials
0 CalARP Required
I
Date Initials
0 CalARP Complete
I
Date Initials
PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air
Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition
permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 1 O working days prior to
commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information.
YES
1. □
2. □
Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the
APCD factsheet at http://www.sdapcd.org/info/facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side
of this from. Contact APCD if you have any questions).
3. □
(ANSVVER ONLY IF QUESTION 1 IS YES) Will the subject facility be located INithin 1,000 feet of the outer boundary of a school (K through 12)?
(Public and private schools may be found after search of the California School Directory at http://www.cde.ca.gov/re/sd/; or contact the
appropriate school district). !I Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos?
i,a. Will there be demolition involving the removal of a load supporting structural member? 4. □
Briefly describe business activities:
I d[clare undel!.enal}y of perjury that to the best of my knoV'l'ledge and b lief
<,un;_ ache; I V
Name of owner or Authorized Agent Date
FOR OFFICIAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _______________________________ _
BY: ____________________________ _ DATE: __ ~/ __ ~/ __ _
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASEO FOR OCCUPANCY
COUNTY-HMO APCO COUNTY-HMO APCO COUNTY-HMO APCO
HM-9171 (04/07) County of San Diego-DEH-Hazardous Materials Division
~CITY OF
CARLSBAD
STORM WATER
COMPLIANCE
ASSESSMENT
B-24
Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www .carlsbadca.gov
I am applying to the City of Carlsbad for the following type(s) of construction permit:
□ Building Permit □ Right-of-Way Permit
Patio/Deck
Re-Roofing
Sign
Spa-Factory
Sprinkler
A project is categorically EXEMPT from
the requirement to prepare a storm water
pollution prevention plan (SWPPP) because it
only requires issuance of one or more of the
following permit types:
Electrical
Fire Additional
Fire Alarm
Fixed Systems
Mechanical
Mobile Home
Plumbing
Water Discharge
Project Storm Water Threat Assessment Criteria*
No Threat Assessment Criteria
□ My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan {SWPPP) because
it meets the 'no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier
Level. My project does not meet any of the High, Moderate or Low Threat criteria described below.
Tier 1 -Low Threat Assessment Criteria
□ My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project
meets one or more of the following criteria:
• Results in some soil disturbance; and/or
• Includes outdoor construction activities (such as roofing, saw cutting, equipment washing, material stockpiling, vehicle fueling, waste
stockpiling).
Tier 2 -Moderate Threat Assessment Criteria
D My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria:
• Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or,
• Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria:
• Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or
• Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or
• Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or
• Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30).
Tier 3 -Significant Threat Assessment Criteria
□ My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or
□ My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, refueling and maintenance areas: or,
D My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant
potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s).
I certify to the best of my knowledge that the above
checked statements are true and correct. I understand
and acknowledge that even though this project does
not require preparation of a construction SWPP, I must
still adhere to, and at all times during construction
activities for the permit type(s) check above comply
with the storm water best management practices
pursuant to Title 15 of the Carlsbad Municipal Code
and to Cltv Standards.
Project Address: Assessor Parcel No.
•The City Engineer may ault1orize minor variances from the Storm
Water Threat Assessment Criteria in special circumstances 'Mlere it
can be shown that a lesser or higher Construction SW PPP Tier Level is
warranted.
B-24
730&
Title:
1'£~~~~?::F:._::.c..,;=._l--/c';:'-Ntvr.'--"'--'-"-'-'ff---'-'-''--='11 vff Date:
(o -:;i..-rg'
Project ID:
□YES □NO
Page 1 of 1 Rev.03/09