HomeMy WebLinkAbout2388 BOTELLA PL; ; CB151123; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
05-28-2015 Residential Permit Permit No: CB151123
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
2388 BOTELLA PL CBAD
RESDNTL Sub Type: RAD
Lot#: 0
Constuction Type: 58
Reference #:
Status: ISSUED
Applied: 04/14/2015
Entered By: JMA
Parcel No:
Valuation:
2163511000
$43,802.00
Occupancy Group:
# Dwelling Units: 0
0
Structure Type:
Plan Approved: 05/28/2015
Issued: 05/28/2015
Bedrooms: Bathrooms: 0
Orig PC#:
Inspect Area:
Plan Check#:
Projec! Title: GANN: 635 SF REMODEL TO
KITCHEN, DINING & FAMILY RM
Applicant:
ANDREW CARLOS
3327 ADAMS ST
CARLSBAD CA 92008-2502
760-579-3996
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Plan Chk Fee
$367.33
$0.00
$257.13
$0.00
$0.00
$5.69
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$2.00
$0.00
Owner:
GANN ERIC&KELL Y
2388 BOTELLA PL
CARLSBAD CA 92009
Meter Size
Add'l Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (31 04193)
License Tax (4304193)
Traffic Impact Fee (31 05541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
Total Fees: $803.53 Total Payments to Date: $803.53 Balance Due:
Inspector: f11· io~< FINAL~~PRQVAL
Date: 6-~ t>4/ Li::> Clearance:
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$61.00
$45.00
$65.38
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$803.53
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has oreviouslv otherwise exoired.
City of
Carlsbad
JOB ADDRESS
(]PLANNING ENGINEERING
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUITE#/SPACE#/UNIT# -co
CT/PROJECT # LOT# #BEDROOMS #BATHROOMS OCC. GROUP
tz-?
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
\NTe\2\ott VlEit\AoCtL-Or S)GS\IN(;-\L-lTCH~; DIN\N&-ANID Fit1N11LLI itUJOM-
AF r-ECTE"YJ ,/Wl€'10. l s (o ~0 SF I score 0 F wo vz. \C VvllL I NCUt IDE VLEv\1\0v'A:l
DF e'!<-t s:l\ l\l(r \?~~~vLn\Ju-AN\0 V\laf\J -\?;t'f1.\.,VLIN6-\;VALV:; . ~Q.t2-(JLV-\CJ~Vv(t;Nr OF
\:::-)'..Tt--rLt c YL-AN 1 N ·oauus A-\\l 'D POO vLS . Vlt.u~., S'T\ILL(cr~.-h1-A<_ CL~( 6-N .
EXISTING USE
APPLICANT NAME 1:;:;..;/} '\r•
Prina Contact t.-V4-.. \...._
PROPOSED USE GARAGE (SF) PATIOS (SF)
ADDRESS
CITY
PHONE
EMAIL
.CONTRACTOR BUS. NAME
CITY
PHONE
EMAIL
STATE LIC.#
STATE
FAX
STATE
FAX
AIR CONDITIONING
YES0No0
ZIP
ZIP
CllY BUS. LIC.#
FIRE SPRINKLERS
YESONoD
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or That he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars {$500}).
Workers' Compensation Declaration: I hereby affirm under penalty of petjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. Policy No. Expiration Date _________ _
This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000}, in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees .
.JiS CONTRACTOR SIGNATURE 0AGENT DATE
I hereby affirm that I am exempt from Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
jl,-,~· If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
L2{ ~-~~ owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
D I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes ~o
2. I (@have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): '\t£70
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
.JiS PROPERTY OWNER SIGNATURE 0AGENT DATE 6-
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby aulhorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolttion or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under lhe provisions of lhis Code shall expire by limitation and become null and void if lhe building or work aulhorized by such permit is not commenced wilhin
180 days from lhe date of such permit or iflhe building or VIOrk aulhorized by such permtt is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
AS APPLICANT'S SIGNATURE DATE
Inspection List
·Permit#: CB151123 Type: RESDNTL RAD
Date _ ~-Jr1spection ltE:)m Inspector
-·-····--~~------·-······
02/04/2016 89 Final Combo
02/04/2016 89 Final Combo MC
12/15/2015 89 Final Combo MC
09/02/2015 17 Interior Lath/Drywall MC
09/02/2015 18 Exterior Lath/Drywall MC
08/31/2015 14 Frame/Steei/Bolting/Weldin MC
08/31/2015 17 Interior Lath/Drywall MC
08/31/2015 18 Exterior Lath/Drywall MC
08/28/2015 16 Insulation PY
08/27/2015 16 Insulation PB
08/25/2015 84 Rough Combo PB
08/10/2015 21 Underground/Under Floor MC
07/30/2015 11 Ftg/Foundation/Piers MC
07/30/2015 14 Frame/Steei/Bolting/Weldin MC
07/28/2015 14 Frame/Steei/Bolting/Weldin MC
Friday, February 05, 2016
Act
Rl
Fl
co
we
AP
AP
AP
co
AP
NR
PA
AP
AP
PA
NR
GANN: 635 SF REMODEL TO
KITCHEN, DINING & FAMILY RM
Comments
NOTICE
AQUARIUM SOFFIT/SHELF
INTERIOR SPREAD FOOTINGS
PRE-LIM HARDWARE AND ELECTRICAL
AT STAIR SHEAR WALL
Page 1 of 1
I
I I
r
!
! ' ~ r
l I l I I ~
i
r
I
!
r !
I I f
i I.
I i J
Carl Schmidt Inspection
(619) 855-9252
. SPECIAL INSPECTION REPORT
':I . /, [')
Project: bAAitJ ~:.,:;. SJ-Qr:.Atk£:.
f) .-1 C;r <:J \') ]-~-' .-:.1 (')L Address: t:: ::> o D :,)Q C ldA-J Y -
City: C4Ji.t-.S~A'O .
Permit Number: C.£; J .$ J 12 S Plan File Number: ----------
TYPE OF OBSERVATIONS:
Reinforcing Steel_ Reinforced Concrete_ Structural Masonry_ Field Welding_
Epoxy~ Prestressed Concrete_ Shop Welding_ Bolting_ Fireproofing_
Nmnber of Samples: Type:----------------~-----
Materials/DesignMix/Psi: ~~1'SoA) .C.,[·r-''f.P
Qp11.. t·\ it-~ 1 '3 V 5 /KV
Date: 7--~0-\ .C::
Carl Schmidt Inspection
(619) 855-9252
SPECIAL INSPECTION REPORT
Project: &1-'vvf\J · RFs&:OfA}C.F.
Address: A '3:> 15g f~dTfLL.A QL
city: C:Af!f .. se>AO
Permit Number: C~} S) \ 2-~ Plan File Number: ----------
TYPE OF OBSERVATIONS:
Reinforcing Steel_ Reinforced Concrete_ Structural Masonry_ Field Welding_
Epoxy'{__ Prestressed Concrete _ Shop Welding_ Bolting __ Fireproofing _
Number of Samples: Type:---------------~-----
. Materials!DesignMi.x!Psi: ?7!n Q6 otJ e?Er~ J< .... 9 .
I}AJ(.,(4 F 01-% I VOti'lV f-tp : L{ -1 1--17
Date: 7-Jf) -J t;;'
REPORT
WORK INSPECTED COf..lJ'ORMS WITH APPROVED PLANS AND SPECIFICATIONS U}.;'LESS OTHER\VISE NOTED _._UW..E.H9....u::U::>:.--~ 11,):>!,.._·-4-J.Fih.....U:· 12"'-l-,J&"""'l.gt:::::.-.. ' _ __::::k'-"""'-'4~ 50"115(..;2 I
Inspector (Print) Certification#
Authorized Job Site Contact Signaf)!f-e/
{/"''
TIME IN: ? : <Ja
General Contractor: () 1 1-EAf..i (' t7?{J >f
I
Address: --------------------------
City:---·-------------
Phone: ------------------------
Ed it -Phalen Farber
My Information
r·Ay CEUs & Certifications
My Transactions & Status
Member Directory
Logout
''J!y CEUs & Certifications 1 Phalen Farber
C~>rtification: CEU Activities for Renewal
CEU
E!wQrt CEU Activity
Activity
Option
CEU Provider CEU Activity Activity
Name Date
Activity CEUs
Quantity Reported
edit Other See Renewal See Renewal
Application Application 07110!2014 5.60 5.60
See Renewal
_AEpl1cati<>O
Certification: Summary
Renewal
Appli<:«~Jon 01118!2011 3.00 3.00
Submit Renewal Ap.Qiication
Certification Program Status Expiration Certification
Date Number
Residential Plumbing Inspector Certified 0711012017 5098621
Structural Welding Special Inspector Certified 07/10/2017 5098621
Commercial Mechanicallnspecior Certified 07/10/2017 5098621
Structural Masonry Special Inspector Certified 07/1012017 5098621
Structural Steel and Bolting Special Certified 07110/2017 5098621 Inspector
Prestressed Concrete Special Certified 07/10/2017 5098621 Inspector
Spray-appHed Fireproofing Special Certified 07110/2017 5098621 lnspe<:tor
l~tj,U,
1 • ·'-c'', ', -;._} --
COPYRIGHT@ 2015!NTERNA110NAL CODE COUNCIL, iNC. ALL RIGHTS RESERVED.
https://av.iccsafe.org/eweb/DynamicPage.aspx?webcode=ICC_MyCertifications&site=ICC
G/30/15, 9:34 AM
Page 1 of 1
EsGil Corporation
In (}!artnersliip witli qovernment for (]3uiCt£ing Safety
DATE: 05/26/15
JURISDICTION: Carlsbad
PLAN CHECK NO.: 15-1123
PROJECT ADDRESS: 2388 Botella Place
PROJECT NAME: Remodel for Gann Residence
SET: II
D APPLICANT
D JURIS.
D PLAN REVIEWER
D FILE
r:gj The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
r:gj EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by:
Mail Telephone Fax In Person
REMARKS: City to place soils stamp on the plans at issuance
By: Ray Fuller Enclosures:
EsGil Corporation
D GA D EJ D MB D PC (P) 05/21/15
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
DATE: 04/21/15
JURISDICTION: Carlsbad
PLAN CHECK NO.: 15-1123
EsGil Corporation
In !Partnersfiip witfi government for c.Bui(tfing Safety
SET: I
PROJECT ADDRESS: 2388 Botella Place
PROJECT NAME: Remodel for Gann Residence
0 APPLICANT ~/JURIS.
0 PLAN REVIEWER
0 FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
C2:J The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
C2:J The applicant's copy of the check list has been sent to:
Andrew Carlos
3327 Adams Street Carlsbad, Ca. 92008
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
ig] EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Andrew Carlos Telephone#: (760) 579-3996
. Email: info@andrewcarlosarchitect.com
.)/.Date coftacted:1rfl·l (by(¥\--)
\/Mail \/Telephone Fax In Person
D REMARKS:
By: Ray Fuller Enclosures:
EsGil Corporation
D GA D EJ D MB D PC 04/16/15
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
Carlspad 15-1123
04/21/15
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 15-1123 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2388 Botella Place
FLOOR AREA:
Remodel 6.35
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 04/14/15
DATE INITIAL PLAN REVIEW
COMPLETED: 04/21/15
FOREWORD (PLEASE READ):
STORIES: Existing 2
HEIGHT: Existing No Change
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 04/16/15
PLAN REVIEWER: Ray Fuller
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 1 05.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.,. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 15-1123
04/21/15
1. Please make all corrections, as requested in the correction list. Submit THREE
sets of plans for residential projects). For expeditious processing, corrected sets
can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Verify final sets of plans and any new calculations will be stamped and signed by
engineer and /or architect of record also. Structural sheets were not signed by
the engineer-of-record.
3. Please clearly indicate on the cover sheet of the plans whether the
existing house was built before or after 1994. For additions or improvements
to a residence built before 1994 please add the following note on the cover
sheet of the plans ~All existing "noncompliant" fixtures (toilets that use more than
1.6 gallons of water per flush, urinals that use more than one gallon of water per
flush, showerheads that have a flow capacity of more than 2.5 gallons of water
per minute, and interior faucets that emit more than 2.2 gallons of water per
minute) shall be replaced. Certification of compliance shall be given to the
building inspector prior to final permit approval. California SB407" .
4. Specify on the plans that any existing smoke alarms that are more than 1 0
years old will be replaced. Section R314.3.2.
5. No energy calculations were provided. Could not determine how must glazing is
being removed as there was no existing door/window sizes given on the demo
plan. Fenestration alterations must meet all requirements of ES 150.1 and Table
150.1-A except:
• 75 sq. /ft. square feet may be added and not be required to meet the total
fenestration or west facing fenestration maximum areas.
• Any new glazing would need to be noted with a .32 U and .25 SHGC value
6. A lot of keynotes provided do not match the plans. Please clarify. For example
see keynote 5 on demo plan, keynotes 2, 3 etc on proposed floor plan. Recheck
all locations.
Carlsbad 15-1123
04/21/15
7. Show or note that garage fire door may swing outward only if the exterior
landing is not more than 1% inches lower than the top of the threshold. R311.3.1.
8. Please add the words self-latching (per current code) to proposed fire door
between garage and dwelling. Section R302.5.1.
9. Plans to reflect if fireplaces are prefab or masonry. If fireplaces are masonry
then the added would need to reflect minimum 2" to combustibles.
10. Not necessarily a correction but could not determine the difference in sheets A2
and A2.0.
11. Please recheck all details to verify that they are complete and/or correct. See for
example where note 8 on sheets A2 and A2.0 state to see sheet AS for the
window schedule .
12. Plans to reflect required fire protection at garage where infilling walls and
opening up a portion of stair well framing at garage side. Section R302.7
13. The City of Carlsbad limits you to 1000 psf for soil bearing unless a soils report
is provided. Calculations are using 1500 .
• CITY of CARLSBAD REQUIREMENTS
14. All new residential buildings, including additions, require a soils report. An update
letter is required if the report is more than 3 years old. If a room addition is less
than 500 sq. ft. in area and only one story, then a soils report is not required. The
maximum allowable soil bearing value used in any design must be 1000 psf
for this exception.
15. If inspection is required, the designer shall complete the city's "Special
Inspection Agreement".
• Note on this list (or a copy) where each correction item has been addressed,
i.e., plan sheet, note or detail number, calculation page, etc.
• Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction
list? Please indicate: Yes ( ) No ( )
• The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
you.
Carlsbad 15-1123
04/21/15
SPECIAL INSPECTION
AGREEMENT
B-45
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed
requires special inspection, structural observation and construction material testing.
'roject!Permit: _________ _ Project Address: ________________ _
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder
a. (If you checked as owner-builder you must also complete Section B of this agreement.)
Name: (Please printi-----------------------------------
(Flrst) [MI) [Last)
Mailing Address""": __________________________________ _
Email_·------------------------Phone: __________ _
I am: DProperty Owner DProperty Owner's Agent of Record DArchitect of Record DEngineer of Record
State of California Registration Numbe · Expiration Date _______ _
AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of
special inspections noted on the approved plans and, as required by the California Building Code.
Signatur"'-------------------------Date: ___________ _
B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder I owner-builder.
Contractor's Company Name: ___________________ Please check if you are Owner-Builder D
Name: (Please print) -------::c-:----------,.---,--------------,----------{FirstJ (MIl (Last)
Mailing Address: ____________________________________ _
Email: ________________________ Phone: __________ _
State of California Contractor's License Number: __________ Expiration Date: _______ _
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
• I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the
building official;
• I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports; and
• I certify that I will have a qualified person within our (the contractor's) organization to exercise such control.
• I will provide a final report I Jetter in compliance with CBC Section 1704. 1.2 prior to requesting final
inspection.
Signature~: ________________________ Date:
B-45 Page 1 of 1 Rev. 08/11
Carlsbad 15-1123
04/21/15
[DO NOT PAY-THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 15-1123
PREPARED BY: Ray Fuller DATE: 04/21/15
BUILDING ADDRESS: 2388 Botella Place
BUILDING OCCUPANCY: R3 U TYPE OF CONSTRUCTION VB
BUILDING AREA Valuation
PORTION (Sq. Ft.) Multiplier
Remodel 635 68.98
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review: [2] Complete Review
0 Repetitive Fee ~Repeats
Comments: No Green Fee
D Other
0 Hourly
EsGil Fee
Reg. VALUE
Mod.
D Structural Only
1-------~IH' @ •
($)
43,802
43,802
$368.091
$239.261
$206.131
Sheet 1 of 1
macvalue.doc +
DATE: PROJECT NAME: GANN
PLAN CHECK
REVIEW
TRANSMITTAL
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
PROJECT ID:
PLAN CHECK NO: SET#: ADDRESS: APN:
VALUA~:
vf ~his plan check review is complete and has been APPROVED by the ENGINEERING
Division.
By:
A Finalmlnspection by the Division is required Yes No
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to:
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
: ' '·, ><':,,'
ENGI~~'~[li,~G,:<·
760-602-2756 :; . ,, >' "''":f -cA:,,', '
Remarks:
E-36
1. SITE PLAN
Provide a fully dimensioned site plan drawn to scale.
Show:
North arrow
Existing & proposed structures
Existing street improvements
Property lines (show all dimensions)
Easements
Right-of-way width & adjacent streets
Show on site plan:
Drainage patterns
Set#
Driveway widths
Existing or proposed sewer lateral
Existing or proposed water service
Submit on signed approved plans:
DWG No.
, Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining
······street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale
5' away from building".
Existing & proposed slopes and topography
Size, location, alignment of existing or proposed sewer and water service(s) that serves the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception.
Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
Site address
Assessor's parcel number
Legal description/lot number
For commercial/industrial buildings and tenant improvement projects, include: total building
square footage with the square footage for each different use, existing sewer permits
showing square footage of different uses (manufacturing, warehouse, office, etc.) previously
approved.
Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
Lot/Map No.:
Subdivision/Tract:
Reference No(s):
Page 2 of 6 REV 6/01/12
E-36
Set#
2. DISCRETIONARY APPROVAL COMPLIANCE
· Project does not comply with the following engineering conditions of approval for project no.:
3. DEDICATION REQUIREMENTS
Dedication for all street rights-of-way adjacent to the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $ 24,000 , pursuant to Carlsbad Municipal Code Section 18.40.030.
For single family residence, easement dedication will be completed by the City of Carlsbad,
cost $1 15.00.
Dedication required as follows:
4. IMPROVEMENT REQUIREMENTS
All needed public improvements upon and adjacent to the building site must be constructed
at time of building construction whenever the value of the construction exceeds
$124,000 00, pursuant to Carlsbad Municipal Code Section 18.40.040.
Public improvements required as follows:
Construction of the public improvements must be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or current grant
deed on the property and processing fee of $ 444~Q.Q,mso we may prepare the necessary
Neighborhood Improvement Agreement. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit. Processing fee $157.00.
Future public improvements required as follows:
Page 3 of 6
CURB, GUTTER, SIDEWALK
UNDERGROUND UTILITIES
REV6/30/10
E-36
Set#
5. GRADING PERMIT REQUIREMENTS
The conditions that require a grading permit are found in Section 15.16 of the Municipal
Code.
Inadequate information available on site plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
remedial). This information must be included on the plans. If no grading is proposed
write: "NO GRADING"
Grading Permit required. NOTE: The grading permit must be issued and rough grading
approval obtained prior to issuance of a building permit.
Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector The inspector will then
provide the engineering counter with a release for the building permit.
No grading permit required.
· Minor Grading Permit required. See attached marked-up submittal checklist for project-
specific requirements.
6. MISCELLANEOUS PERMITS
RIGHT -OF-WAY PERMIT is required to do work in city right-of-way and/or private work
adjacent to the public right-of-way. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
Right-of-way permit required for: Driveway
Page 4 of 6 REV6/01/12
E-36
Set#
7. STORM WATER
Construction Compliance
Project Threat Assessment Form complete.
Enclosed Project Threat Assessment Form incomplete.
Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form
and return (SW )
Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Post-Development (SUSMP) Compliance
· Storm Water Standards Questionnaire complete.
Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign
the questionnaire and resubmit with next submittal.
. Project is subject to Standard Storm Water Requirements. See city Standard Urban
Storm Water Management Plan (SUSMP) for reference.
Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
Rainwater harvesting (rain barrels or cistern)
Vegetated Roof
Bio-retentions cell/rain garden
Pervious pavement/pavers
Flow-through planter/vegetated or rock drip line
. Vegetated swales or rock infiltration swales
Downspouts disconnect and discharge over landscape
Other:
Page 5 of 6 REV 6/01112
Attachments:
E-36
Set#
9. WATER METER REVIEW
Domestic (potable) Use
What size meter is required?
Where a residential unit is required to have an automatic fire
extinguishing system, the minimum meter size shall be a 1" meter.
NOTE: the connection fee, SDCWA system capacity charge and the
water treatment capacity charge will be based on the size of the meter
necessary to meet the water use requirements.
8. FEES
For residential units the minimum size meter shall be 5/8", except where
the residential unit is larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be%".
Required fees have been entered in building permit.
Drainage fee applicable
Added square feet
Added square footage in last two years?
Permit No.
Permit No.
Project built after 1980
Impervious surface> 50%
Impact unconstructed facility
yes
yes
yes
yes
no
no
no
no
Fire sprinklers required
Upgrade
No fees required
yes
yes
no (is addition over 150' from center line)
no
Engineering Application Storm Water Form Right-of-Way Application/Info. Reference Documents c
Page 6 of 6 REV 6/01112
Fee Calculation Worksheet
ENGINEERING DIVISION
Prepared by: Date: GEO DATA: LFMZ: I B&T:
Address: Bldg. Permit#:
Fees Update by: Date: Fees Update by: Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq.Ft.!Units EDU's:
Types of Use: Sq.Ft.!Units EDU's:
Types of Use: Sq.Ft.!Units EDU's:
Types of Use: Sq.Ft./Units EDU's:
ADT CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq.Ft./Units ADT's:
Types of Use: Sq.Ft.!Units ADT's:
Types of Use:
Types of Use:
FEES REQUIRED:
Sq.Ft./Units
Sq.Ft.!Units
ADT's:
ADT's:
Within CFD: ~YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) 'NO
1. PARK-IN-LIEU FEE: NW QUADRANT NE QUADRANT 'SE QUADARANT ,, SW QUADRANT
ADT'S/UNITS: I X FEE/ADT: I =$ D
2.TRAFFIC IMPACT FEE:
ADT'S/UNin . X FEE/ADT: I=$ D
3. BRIDGE & THOROUGHFARE FEE: DIST. #1 DIST.#2 DIST.#3
ADT'S/UNITS: ~ FEE/ADT: 1=$ D
4. FACILITIES MANAGEMENT FEE ZONE:
ADT'S/UNITS: X FEE/SQ.FT./UNIT: I=$ D
5. SEWER FEE
EDU's IX FEE/EDU: I=$ D
BENEFIT AREA:
EDU's IX FEE/EDU: I=$ D
6. DRAINAGE FEES: PLDA: HIGH MEDIUM LOW
ACRES: IX FEE/AC: I=$ D
7. POTABLE WATER FEES:
UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
P-29
DATE: 4-15-15 PROJECT NAME: PROJECT ID:
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e:ov
PLAN CHECK NO: CB 15-1123 SET#: 1 ADDRESS: 2388 Botella Place APN: 206-315-10-00
L8J This plan check review is complete and has been APPROVED by the Planning
Division.
By: Chris Sexton
A Final Inspection by the Planning Division is required Yes No
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check APPROVAL has been sent to: info@andrewcarlosarchitect.com
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
760-602-4610
~ Chris Sexton
760-602-4624
Chris.Sexton@carlsbadca.gov
D Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
D
Remarks:
ENGINEERING
760c602-2750
FIRE PREVENTION
760-602-4665
Project Address:
PLUMBING,
ELECTRICAL,
MECHANICAL
WORKSHEET
B-18
Permit No.:
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Building@carlsbadca.gov
Information provided below refers to wor~ being done on the above mentioned permit only.
This form must be completed and returned to the Building Division before the permit can be issued.
Building Dept. Fax: (760) 602-8558
· · 2 -51N\L vrrcu l-LA-\1 \-WL. Number of new or relocated f1xtures, traps, or floor drams ............. ; ................ 1;;-••••••••• r.J ....•..... __
New building sewer line? ......................................................................................... Yes __ No~
Number of new roof drains?............................................................................................................... N JA.
Install/alter water line? ..................................................................................................................... ~\\:=N\7} t~-\'2oiAlt"
Number of new water heaters?......................................................................................................... .t:::t'
Number of new, relocated or replaced gas outlets? .................................................................... __l_:, STO~€
Number of new hose bibs?.................................................................................................................. N /A-
Residential Permits:
New/expanded service: Number of new amps: -~N"-')'-A ____ _
Minor Remodel only: Yes__k_ No
Commercial/Industrial:
Tenant Improvement: Number of existing amps involved in this project:
Number of new amps involved in this project:
New Construdion: Amps per Panel:
Single Phase ............................................................... Number of new amperes ______ _
Three Phase ................................................................. Number of new amperes ______ _
Three Phase 480 ........................................................ Number of new amperes ______ _
Number of new furnaces, A/C, or heat pumps? ............................................................................ _!/)___
New or relocated duct worh? .......................................................................... Yes ,X No
Number of new fireplaces? ................................................................................................................ ~
Number of new exhaust fans? ........................................................................................................... . ~
Relocate/install vent? ........................................................................................................................... .
Number of new exhaust hoods?........................................................................................................ l-9~
Number of new boilers or compressors? ........................................................... Number of HP --fl2-
B-18 Page 1 of 1 Rev. 03/09
l.A COST'A
ENGINE:I:RJlrNG
2226 FARADAY AVENUE
CARLSBAD, CALIFORNIA 92008
TEL 760·931·0290 FAX 438·5251 martv_mont~omery@yahoo.com
CIVIL • STRUCTURAL
MECHi\NICA.L • PETROLEUM
STRUCTURAL CALCULATIONS
PROJECT:
ENGINEER:
GANN RESIDENCE
2388 BOTELLA PLACE
CARLSBAD, CA 92009
MARTELL B. MONTGOMERY
R.C.E. 50344 EXP. 6-30-15
DATE: APRIL 7, 2015
DESIGN LOADS: 2012 IBC, 2013 CBC
Roof: Floor:
18 psfDL 10 psfDL
20 psfLL 40 psfLL
38 psfTL 50 psfTL
'-.
Seismic Properties:
Seismic Design Category: D
Occupancy II
I= 1
Exterior Wall:
15 psfDL
Interior Wall:
8 psfDL
Wind Properties:
Envelope Procedure: 28.1
Exposure B
Io:l.O
RECEIVED
APR 14 2015
CITY OF CARLSBAD
BUILDING DIVISION
R= 6.5
Ss: 1.058
3-s Gust Wind Speed: 110 mph
Pmin= 8 psf Roof
S1: 0.409 16 psf Floor
Site Class: D
Fa: 1.077
Fv: 1.591
Sns: 0.76
SD1: 0.434
' ' ' ~
2012 NOS MATERIAL SIZE-STRUCTURAL PROPERTIES
DOUGLAS FIR-LARCH (DF, DF-L)
BEAMS & POSTS& LIGHT FRMING RAFTERS,
STRINGERS-#1 TIMBERS-#1 JOISTS-#1 /#2 STUDS-#2
E= 1.6E+06 psi E= 1.6E+06 psi E= 1.6E+06 1.6E+06 psi E= 1.4E+06 psi
f= v 170 psi f= v 170 psi fv= 180 180 psi f= v 180 psi
f= c 925 psi f= c 1000 psi fc= 1500 1350 psi f= c 850 psi
f'Y'= 625 psi f'Y'= 625 psi f'Y'= 625 625 psi f'Y'= 625 psi
ft= 675 psi ft= 825 psi ft= 675 575 psi ft= 450 psi
fb= 1350 psi fb= 1200 psi fb= 1000 900 psi fb= 700 psi
2XMEMBERS 4XMEMBERS 6XMEMBERS
2x4 4x4 6x4
A= 5.3 in2 A= 12.3 in2 A= 19.3 in2
S= 3.1 in3 S= 7.1 in3 S= 11.2 in3
I= 5.4 in4 I= 12.5 in4 I= 19.7 in 4
2x6 4x6 6x6
A= 8.3 in2 A= 19.3 in2 A= 30.3 in2
s = 7.6 in3 s = 17.6 in3 s = 27.7 in3
I= 20.8 in4 I= 48.5 in4 I= 76.3 in4
2x8 4x8 6x8
A= 10.9 in2 A= 25.4 in2 A= 39.9 in2
s = 13.1 in3 s = 30.7 in3 s = 48.2 in3
I= 47.6 in4 I= 111.1 in4 I= 174.7 in4
2x10 in2 4x10 6x10
A= 13.9 in3 A= 32.4 in2 A= 50.9 in2
s = 21.4 in4 s = 49.9 in3 s = 78.4 in3
I= 98.9 I= 230.8 in4 I= 362.7 in4
2x12 in2 4x12 6x12
A= 16.9 in 3 A= 39.4 in2 A= 61.9 in2
s = 31.6 in4 s = 73.8 in3 s = 116 in3
I= 178 I= 415.3 in4 I= 652.6 in4
2x14 4x14 6x14
A= 19.9 in2 A= 46.4 in2 A= 72.9 in 2
s = 43.9 in3 S= 102.4 in3 S= 160.9 in 3
!= 290.8 in4 I= 678.5 in4 I= 1066.2 in4
4x16 6x16
A= 53.4 in2 A= 83.9 in2
S= 135.7 in3 s = 213.2 in3
I= 1034 in4 I= 1625.5 in4
. J
STRUCTURAL CALCULATIONS
VERTICAL
FLOOR
FLOOR BEAMS:
FB-1 (KITCHEN):
L=~ft
w= ~ lb/ft
V=wl/2= 3948 lb
M=wl ~/8= 10364 ft-lb
TRY ... 5 1/4 x 111/4 2.0E PSL
Va= 11420 lb
Ma= 26955 ft-lb
I= 625 in4
LhL =5wl 4/(384EI)= 0.165 in
1/(6TL/l)= 766 >240? YES
6LL =LL(6TL)/Tl= 0.132 in
1/(6LL/l)= 957 >480? YES
6oL =6TL-,0,LL = 0.033 in USE 5 1/4 x 11 1/4 2.0E PSL
FB-2 (KITCHEN/SITTING):
L=~ft V=wl/2= 4888 lb
w= 752 lb/ft M=wl~/8= 15886 ft-lb
TRY ... 5 1/4 x 11 1/4 2.0E PSL
Va= 11420 lb
M-a-26955 ft-lb
I= 625 in4
6TL =5wl 4/(384EI)= 0.387 in
1/(6TJL)= 404 >240? YES
6LL =ll(6TL)/TL= 0.309 in
l/(6LJL)= 504 >480? YES
6oL =6TL -6LL = 0.077 in I use 5 1/4 x 11 1/4 2.0E PSL
\,
1
' " ---DESIGN PROPERTIE.
r
2.0E PARALLAM® PSL ALLOWABLE DESIGN STRESSES
(100% LOAD DURATION)
t
Shear modulus of elasticity G 125,000 psi E~~~,..,~~l Modulus of elasticity E 2.0 x J06 psi
Flexural stress Fb 2900 psi11J
Compression perpendicular to grain
650 psi12)(3) para lief to wide face of strands F cJ. =
Compression parallel to grain Fell = 2900 psi
Horizontal shear perpendicular
to wide face of strands Fv = 290 psi
(1) For 12-inch depth. For others, multiply by [~2 JD·111
(2) F cJ. shall not be increased for duration of load.
(3) 7 50 psi for all Eastern Species Paraltam® PSL and I%" thick Western Species Para Ham® PSL
ALLOWABLE DESIGN PROPERTIES (100% LOAD DURATION)
B~" 2.0E Parallam® PSl
3%" 2.0E PARALLAM® PSL
6,430 7,615_ 8,035 9,475
250 415 490 800 1,195 1,700
10.4 12.3 13.0 15.3 17.5 19.7
7" 2.0E PARALLAM® PSL
211fla" 2.0E PARALLAM® PSL
4,935 5,845 6,170 7,275 8,315 9,350
175. 190 320 375 615 915 1,305
7.8 8.0 9.5 10.0 11.8 13.4 15.1
51f411 2.0E PARALLAM® PSL
9,645 11,420 12,055 14,210 16,240 18,270
375
~~~~;;,yo~s:~;ri~;_fi.X. 15.2 15.6
GENERAL ASSUMPTIONS FOR
NON-TREATED PARA,LLAM® PSL
625
18.5
735 1,200 1,790 2,550
19.5 23.0 26.3 29.5
• Lateral support is required at all bearing points and along compre!;ion edge at
intervals of 24" on-center or elmer;
• Para Ham® P5L beams ;,re m~de without c~~ber; therefore, in addition to· com-
plying with the· deflection limits of the applfl;able building code; other consider-
ations, such as long term deflection under sus~ained loads (including creel"),
pending (positive drainage is essential) and aestretics, must be evaluated.
8 Roof members shall either be sloped for drainag~ or designed to account for
load .and _deflection as specified in the app!icablb building code. 1
• Reductions applied in accordance with: 1994 USC 1606, 1996 NBC 1606 and
1994 SBC 1604 for floor live load; 1994 UBC 1606, 1996 NBC 1607 and 1994
SBC 1604 for roof live load in non-snow ( 125%) conditions.
• 3Y2" members may be two pieces of 1%" or a single 3%" width beam.
5%" members may be three pieces 1'%", one piece 1o/4" with one piece 3%",
or a single 5%" width beam.
7" members may be two pieces!%" around one piece 3%", two pieces 3%",
.or a single 7" width beam.
See pages 16 and 1 7 for multiple member beam connections. -
. '
FB-3 (STAIR/DINING):
L=~fl
w= 743 lb/ft
TRY ... 4x 12
I= 415.3 in4
LlTL =5wl 4/(384EI)= 0.010 in
1/(LlrL/l)= 5234 >240?
FB-4 (SITTING/DINING):
L= c:=:_g] ft
w= ~ lb/ft
V=wl/2= 1672 lb
M=wl2/8= 1881 ft-lb
LlLL =LL(LlrL)/TL=
1/(LlLL/l)=
YES L'loL =LlrL-LlLL =
V=wl/2= 5118 lb
M=wl 2/8= 15354 ft-lb
TRY ... 5 1/4 x 11 1/4 2.0E PSL
V= a 11420 lb
Ma= 26955 ft-lb
I= 625 in4
LlrL =5wl 4/(384EI)= 0.318 in
1/(LlrL/l)= 452 >240? YES
LlLL =LL{LlrL)ITL= 0.255 in
1/(LlLL/l)= 565 >360? YES
AR=1.5(V)ffv=
SR=M/(fb *Co *CF)=
Co= 1
CF= 1.1
0.005 in
10626 >480?
0.005 in
L'loL =LlrL-LlLL = 0.064 in USE 5 1/4 x 11 1/4 2.0E PSL
1ST FLOOR HEADERS:
CHECK (E) REDUCED-SPAN HEADER (FAMILY RM):
L=~fl V=wU2= 833 lb AR=1.5(V)ffv=
w= ~66 lblft M==wl2/8= 520 ft-lb SR=M/(f b *Co *CF)"'
" -1 vo-
TRY ... 4x~ CF= 1.3
I= 48.5 tl in· DLL =LL(LlrL)/TL= 0.004 in
LlrL =Swl 4/(384EI)= 0.008 in 1/(L~LL/L)= 8074 >480?
1/(LlrL/l)= 3977 >240? YES L'loL=LlrL-LlLL= 0.004 in
13.93 in 2
22.8 in 3
YES I USE 4 X 12
6.94 in2
5.3 in3
YES
I USE MIN. 4x6
.
J
HEADER (KITCHEN):
L=~ft
w= ~ lblft
TRY ... 4x6
I= 48.5 in4
6.TL =5wl 4/{384EI)= 0.024 in
1/{f,TL/l)= 1739 >240?
HEADER (SITTING):
L=~ft
w= 555 lb/ft
V=wl/2=
M=wl2/8=
YES
V=wl/2=
M=wl2/8=
TRY ... 3 1/2 x 11 1/4 2.0E PSL
Va= 7615 lb
Ma= 17970 ft-lb
I= 415 in4
6.TL =5wl 4/{384EI)= 0.312 in
1 /( f,TL/l)= 462 >240? YES
t,LL =ll(6.TL)/Tl= 0.163 in
1/(f,LL/l)= 883 >480? YES
6.oL=f;TL-6_LL= 0.149 in
HEADER (DINING):
L=~ft V=wl/2=
w= 555 lb/ft M=wl2/8=
TRY ... 4x8
I= 111.1 in4
6.TL =5wl 4/(384EI)= 0.044 in
1/(f,TL/l)= 1367 >240? YES
971 lb AR=1.5{V)/fv= 8.09 in2
850 ft-lb SR=M/(fb *Co *CFl= 8.7 in3
Co= 1
CF= 1.3
6.LL =ll(6.TL)/Tl= 0.012 in
1/(f;LL/l)= 3531 >480? YES
6.oL =6_TL-6_LL = 0.012 in I USE 4x6
3330 lb
9990 ft-lb
USE 3 1/2 x 111/4 2.0E PSL
1388 lb AR=1.5{V)ffv= 11.56 in2
1734 ft-lb SR=M/(fb *Co *CFl= 17.8 in3
Co= 1
CF= 1.3
6.LL =LL{ 6.TL)/TL= 0.023 in
1/(f;LL/l)::: 2596 >480? YES
LloL =6_TL-6_LL = 0.021 in I USE 4ill
HEADER (DINING):
L=~ft
w= ~ lb/ft
TRY ... 4x6
I= 48.5 in4
f~TL =5wl 4/(384El)= 0.037 in
1/{f~TL/l)= 1286 >240?
HEADER (GARAGE/ENTRY):
L=~ft
w= ~ lb/ft
TRY ... 4x6
I= 48.5 in4
f~TL =5wl 4/(384EI)= 0.017 in
1 /( f~TL/l)= 2063 >240?
V=wl/2=
M=wl2/8=
YES
V=wl/2=
M=wl2/8=
YES
7
1006 lb AR=1.5{V)/fv= 8.38 in2
1006 ft-lb SR=M/(fb *Co *CF)= 10.3 in3
Co= 1
CF= 1.3
fiLL =ll( f~TL)/Tl = 0.020 in
1/( f~LL/l)= 2443 >480? YES
floL =fiTL-fiLL = O.D18 in I USE 4x6
1115 lb AR=1.5{V)/fv= 9.29 in2
836 ft-lb SR=M/{fb *Co *CF)= 8.6 in3
Co= 1
CF= 1.3
fiLL =LL(f~TL)/TL= 0.009 in
1/(f~LL/l)= 3920 >480? YES
floL =f~TL -fiLL= 0.008 in I USE 4x6
',
I
Posts
Example Post Design for 4 x 4 of Length 10'
For Douglas Fir-Larch per NDS 2005,
E=l.6xl06 psi (for 2-4" wide)
Fc=l350 psi (for 2-4" wide)
L=lO'
d=3.5", h=3.5"
Ke=l
L./d= Ke *L /d=l *10'(12 inlft)/3.5"=34.3
IfL./d:5ll, thenF'c=Fc
If 11 <L./d:5K, then F' c=F c[l-1/3(L./d)/K))4]
IfK <L./d:550, then F' c=0.3E/(L.!di
K=0.671(E/Fc)112
=0.671(1.6x106 psi/1350 psi)112
=23.1
23.1 <34.3 :550, F' c=0.3(1.6xl 06 psi)/34.32=408.3 psi
Pa=F'c(d)(h)=408 psi(3.5"i=5002lb
Allowable Load (lb)
Length Cross-section (in x in)
L (ft) 4x4 4x6 4x8 6x4
2 16538 25988 34256 25988
3 16538 25988 34256 25988
4 15853 24911 32838 25988
5 14866 23360 30793 25988
6 13071 20539 27075 25094
7 10208 16042 21146 24332
8 7813 12282 16190 23164
9 6175 9704 12792 21465
10 5002 7860 10361 19094
11 4134 6496 8563 16042
12 3474 5459 7195 13479
13 2960 4651 6131 11485
14 2552 4010 5286 9903
15 2223 I 3494 4605 8627
16 1954 I 3070 4047 7582
17 1731 2720 3585 6716
18 1544 2426 3198 5991
' 19 1386 2177 2870 5377
20 1251 1965 2590 4853
21 1134 1782 2350 4401
22 1033 1624 2141 4010
6x6
30250
30250
30250
30250
29679
29193
28447
27361
25847
23804
. 21120
18049
15562 I
13556
11915 --' 10554 ..._,__
9414
8449
7626
6917
6302
Foundations
Soil bearing pressure (Ps): 1500 psf
Check New/Exist. Continuous 2-Story Footing
w=l 883llb/ft
Story= 2
Width 0. 767 ft
B=(w/Ps)112= 9.2 in
B=CJ])in
D=~in
As=pbd= 0.26 in2 Try (2)-#4:
Table 1806.2, CBC 2013
0.40 in2 > 0.26 in2
USE EXIST. 12 W x 18 D continuous footing, 2500 psi
w/ (2)-#4 Top & Bottom
Check New Point Load on Exist. 2-Story Continuous Footing
Spread Footings
rpAD#
1 I
2
3
44 in
B= 12 in
4 in Pa=W*B*Ps= 5500 lb
18 in P max= 3948 < 5500 lb OK
As=pbd
Footing Size As(in2) j Reinforcement L
30 w X 12 D * 0.49 (3)-#4 E.W, J ---30 \1\f X 18 D 0.81 (4)-#4 E.W. ~I YY
36 w X •18 D 0.97 (5)-#4 E"Y_~
* -"Underpinned" Footing
Lateral Calculations
Wind Loads -(Envelope Procedure) 28.1
Roof slope= I 51112
18.4 psf
P=qh[(GCpt) -(GCpi)] =
@Roof:
@Walls:
Wind Distribution:
k= z
10.0 12§!
17.5 12§!
16 psf Walls 28.4.4
8 psf Roof
2nd Roof-Main House/ Remodel Area
wp=(5.75')(10.0)+(8'/2)(17.5)= 128 lb/ft
Wpmin=(5. 75')(8)+(8'/2)(16)= 110 lb/ft
Floor-Main House/ Remodel Area
wp=(8'/2+1.0'+8'/2)(17.5)= 158 lb/ft
Wpmin=(B'/2+1.0'+8'/2)(16) = 1441blft
J st Roof-Main House/ Remodel Area
wp=(11.5')(1 0.0)+(8'/2)(17.5)= 185 lb/ft
Wpmin=(11.5')(8)+(8'/2)(16)= 156 lb/ft
0.18 Enclosed Table 26.11-1
0.54 Surface 1 Fig. 28.4-1 Case A
-0.45 Surface 2 Fig. 28.4-1 Case A
0.77 Surface 1 E Fig. 28.4-1 Case A
-0.72 Surface 2E Fig. 28.4-1 Case A
0.4 Surface 5 Fig. 28.4-1 Case 8
0.61 Surface 5E Fig. 28.4-1 Case 8
0.70 Table 28.3-1 EXP. 8
1.0 26.8.2
0.85 Table 26.6-1
110 mph, 3s Gust, Fig. 26.5-1A
kEY MA~
t=. j... \ ~' f:-\.0..~ -..J-)ft\.L
F-"'f • .zt-~~ S't"O~'-\ "•-'lltU...
(...:>') {{n'l2-o'F-\l' s~~ w!M-\..
( tJ ~ 1>-Mu. \..i tJ'C'
Seismic Loads
Ss= 1.058
S1= 0.409
Site Class: D
F= a 1.077
F= v 1.591
R= 6.5
I= 1.0
Floors: 2
SMs=F aSs= 1 .140
SM1=FvS1= 0.651
Sos=2/3SMs= 0. 760 SOC: D
So1=2/3SM1= 0.434
SIMPLIFIED DESIGN PROCEDURE (ASCE 712.14)
E=Eh+Ev
E=Eh-Ev
Eh=QE=V
(For load comb. 5 & 6 ASD)
(For load. comb 8 ASD)
Ev=0.2SosD= 0 for E acting in plane of diaphragm/base shear
Seismic Base Shear (per ASCE 12.14.8.1)
V=FSosW/R F= 1.1
R= 6.5
V= 0.129 W
Vertical Distribution (per ASCE 12.14.8.2)
F x=FS0s/R*wx
F= 0.129 Wx
Design Maps Summary Report ht1p:/ I ehp4-earthquake.cr. usgs .gov I designmaps/us/ sunnnary. php ?templ ...
1 ~.C 1
EUSGS Design Maps Summary Report
User-Specified Input
Report Title Gann Residence
Fri AprillO, 2015 03:19:32 UTC
Building Code Reference Document ASCE 7-10 Standard
(which utilizes USGS hazard data available in 2008)
Site Coordinates 33.08373°N, 117.25626°W
Site Soil Classification Site Class D -"Stiff Soil"
Risk Category !/II/III
USGS-Provided Output
s. = 1.058 g
s, = 0.409 g
SMs = 1.140 g
SMl = 0.651 g
Sos = 0.760 g
S01 = 0.434 g
For information on how the SS and 51 values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
MCE" Response Spectrum
0.98
Q.SCI
Period~ T (sed
For PGAM, Tu CRs, and CR1 values, please view the detailed report.
Design Response Spectrum
O.G!:J C.90 1.00 Li!O 1.40 l.GO
Period, T (sec)
Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of
the data contained therein. This tool is not a substitute for technical subject-matter knowledge.
Seismic Distribution
DLroor 18 psf
DLfloor=
DLwallext=
LineA
2ND ROOF
Lnne=
Hwall=
FLOOR
Lline=
Hwall=
line 2
2ND ROOF
Lline=
Hwall=
FLOOR
Lnne=
Hwall=
Line 3
2ND ROOF
Lnne=
Hwau=
FLOOR
Lnne=
Hwall=
10 psf
15 psf
a~~ ft
a~~ ft
ES]ft
ft
ES]fl
ft
a~~ ft
a~~ ft
wR= (38')18= 684 lb/ft WIND
Ww= 2(8'/2)15= 120 lb/ft GOVERNS
v = 0.129(684+120)= 103 lb/ft
wF= (38')1 0= 380 lb/ft WIND
Ww= 2(8'/2+8'/2)15= 240 lb/ft GOVERNS
v = 0.129(380+240}= 80 lb/ft
wR= (27.5')18= 495 lb/ft WIND
Ww= 2{8'/2)15= 120 lb/ft GOVERNS
v = 0.129(495+120)= 79 lb/ft
wF= (27.5')10= 275 lb!ft WIND.
Ww= 2(8'/2+8'/2)15= 240 lb/ft GOVERNS
v = 0.129(275+240)= 66 lb/ft
wR= (12')18= 216 lb!ft WIND
Ww= 2(8'/2)15= 120 lb/ft GOVERNS
v = 0.129(216+120)= 43 lb/ft
wF= (12')10= 120 lb/ft WIND
Ww= 2(8'/2+8'/2)15= 240 lb/ft GOVERNS
v = 0.129(120+240)= 46 lb/ft
Diaphragm/Shear Loads
RA 2R= 0.6(128 lb!ft)(27.5'/2)=
RA F= 0.6(158 lb/ft)[(27.5'/2)=
Use Load Combination 2.4.1 ASCE 7-10: #5:
D + (O.SW or 0.7E) for Wind/Seismic Loads
~lb
~lb
R2 ZR/1 R= 0.6{[( 128 lb/ft)(38'/2)( 12'/27 .5')+( 185 lb/ft)(50'/2)( 15.5'/27 .5')](27 .5'/52')}=
1 116411b
R2 F= 0.6{( 158 lb/ft){(38'/2)( 12'/27 .5')+(24'/2)( 15.5'/27 .5')](27 .5'/52')}=
R3 2R= 0.6(128 lb/ft)(14'/2)=
R3F= 0.6(1581b/ft)(14'/2)=
Drag Loads
FLOOR:
Line 2: (27 lb/ft)( 16.5 ft)= 4461b
...-, -75--.5,1b
~lb
~lb
USE ST 6224
28 lb!ft
34 lb/ft
42 lb/ft
27 lb/ft
45 lb/ft
55 lb!ft
SHEAR WALLS: Seismic: Use Load Comb.#8 2.4.1 ASCE 7-05 (12.14.3.1.3)
(0.6D-0.14S08D) = 0.49 D
Wind:
LINE
Distribution:
Fir. W# H' W#H'
2 1056 17 17952
1 1304 8 10432
Tot. O.T.M.= 28384 ft-lb
1 Fir. v= 143 lb/ft Use Typel
Use Load Comb.#?
(0.6D)
A WALLS:
l.:Ls.w.=
OTM=
RM=
UPLIFT=
1 I Wall
Check Perforated Shear Wall Design:
8'-0" NET (LINE A, 11 '-6" WALL @1ST FLOOR)
WALL UNIT SHEAR = (10561b + 13041b)/16.5' = 1431b/ft
2.4.1 ASCE 7-05
ft. exist. wall)
6881 ft-lb
1080 ft-lb 0.6[(2'/2 +1.5')(18)+(8')(15)
1450 lb +(12'/2)(1 0)](4')2/2
USE HDU2 w/ RETROFIT 5/8" a. b. x 1 0"
EMBED. INTO EXIST. CONC. USE
SET -XP EPOXY, ESR-2508, FOLLOW
ALL MANUFACTURER RECOMMENDATIONS.
PIER UNIT SHEAR= (143 lb/ft)(11.5')/(6' + 2') = 206 lb/ft GOVERNS
DRAG FORCE= 3.5'(206-143) = 2191b
EFFECTIVE h/w= 3.5'/2'= 1. 75: 1 OK USE CS16 STRAP (Lm;n=4')
LINE
Distribution:
Fir. W# H' W#H'
2 1164 17 19788
1 755 8 6040
Tot. O.T.M.= 25828 ft-lb
1 Fir. v= 183 lb/ft Use Typel
LINE
Distribution:
Fir. W# H' W#H'
2 538 17 9146
1 664 8 5312
Tot. O.T.M.= 14458 ft-lb
2
1
3
WALLS:
I:Ls.w.=
OTM= 25828 ft-lb
RM= 12456 ft-lb 0.6[(34'/2)(18)+(8')(8)
UPLIFT= 1274 lb +(1.33'/2)(1 0)](1 0.5')2/2
lwall
USE HDU2 w/ RETROFIT 5/8" a.b. x 10"
EMBED. INTO EXIST. CONC. USE
SET -XP EPOXY, ESR-2508, FOLLOW
ALL MANUFACTURER RECOMMENDATIONS.
WALLS:
Uplift at 1st Floor( j 2 ft. exist. wall)
I:Ls.w.= 12 ft
OTM= 14458 ft-lb
RM=
UPLIFT=
10134 ft-lb
360 lb
0.6[(14'/2 +1.5')(18)+(5')(15)
+(1.33'/2)(1 0)](12')2/2
1 Fir. v= 100 lb/ft Use Type._I __ 1 _ _...1Wall
USE HDU2 w/ RETROFIT 5/8" a.b.,10"
Check Perforated Shear Wall Design:
8'-0" NET (LINE 3, 12'-0" WALL @1ST FLOOR)
WALL UNIT SHEAR = (538 lb + 6641b)/12' = 100 lb/ft
EMBED. INTO EXIST. CONC. USE
SET -XP EPOXY, ESR-2508, FOLLOW
ALL MANUFACTURER RECOMMENDATIONS. I
PIER UNIT SHEAR= (100 lb/ft)(12')/(4' + 4') = 150 lb/ft GOVERNS
DRAG FORCE= 4'(150-100) = 200 lb
EFFECTIVE h/w= 5'/4'= 1.25: 1 OK USE CS16 STRAP (Lmin=4')
Uo
-SHEAR SCHEDULE ~V. PER 21Z>1~ CALl!=. 6LDGI. CODE (IIIZ>1121Z>I4) ·-~ WALL NAILING FOUNDATION Sl-leAR TRANSF'eR L
&.W. SI-IEA!"! WALL t1ATERIAL NAIL PANEL INTER Vz 114>x11Z>11 MIN. MIN. BOTTOM NAILS AND A-S!!> TJI 6LK'C!s MICRO LAM ~IM JST /6LK'C!s s.w. WALL VALUE eDG:E SPACE A.6.SFAC'C!s PLATE NAILING: 6LOCKt:o SPACING TO PLATES WI SIMPSON CLIPS WALL
1 2E>IZ> 318" CDX 0~ OSB FL YWD ** eel "'II 1211 3211 ole:. IE>d e Ill'" ole 16d • 6" ole:. 1611 16d"' 6" ole:. ASS e 16" ole:. 1
2 .S!>IZ> :!>/€!>" CDX OR 0&6 FL YWD ** ed 4" 1211 2411 C?le 16d e Ill'" ole:. 16d e 4 11 ole 12" 16d e 6" ole ASS e 12" ole 2
*3 4'00:1 316" CDX 01'<: OSB FL YWD, ** 8d 3" 1211 2411 ole:. 31&"x6' LAGoS 1611 16d "'4" ole a~~ 16d "'6" ole A3S e &"ole *3 3 x SILL ole <PREDRILL> STAG:G:EIED
*4 lb41Z> 318" CDX 0~ OS6 FL YWD, ** ed 211 1211 1211 ole .lll811x6' LAGoS 1211 16d "'4" ole e" 16d e 6" ole ASS e 811 ole *4 3 x SILL. ole:. (F'F<f:DRILLJ ST AG:G:EIED
*5 111Zl 112" CDX 01'<: OS6 FLYWD, *** I!Zld 211 1211 511 ole 318"x6' LAGoS '.!l" 1E>d e 4" ole:. 6" 16d "'6" ole AS!> e 6" ole *!:> 3 X &ILL ole <PREDRILL> ST AG.G:EJED
*b 811Zl 112" FL YUJD, &TRUe I *** I!Zld 2" 12" 8" ole ::11e"x6' L.AG:S e" 1E>d "'4" ole 6" 16d .. 6" ole A3& e 6 11 ole *10 3 >c SILL ole (FF<ED~ILLJ STAG.G:EF<ED
110 18el 1/8" STUcco WI PAf>E~ eKD. l1 GoA. 1-112" I&" 611 48" ole 16d e I!Zl" ole 16d e 8" ole 24" 16d • 6" ole AS& e 24" ole 10 LATH 114" l"U~Fi!ING MIN.> 1116" I-lEAD ----
SHEAR SCHEDULE NOTES
I * mAMINc!i AT .i>,DJOININCil F'AI\II:L EDGES SI-IALL NOT 6E LESS TI-IAN .Sx OF<
WIDE~ AND NAILS Sl-I.C,LL Bl:: STAGGEF<ED. ** USE ecl(2vz'xfZ>.131" COM1'10N, 2V2"XIZ>.113 GALV. 60X) * * * U6E IIZ>d(3"xl!1'.146" COMI"10N, 3"x!Zl.128" GAL V. BOX)
A. U6E CDX, cc, OR 6RD WI E><T. GLUE IN LIEU 01= STFCUcTUR.AL FL YWOOD.
TI-IESE VALUE:S ARE !=OR DOUG. FIR. OTf..JER LUMBER SPEciES MAY ~QUIRE
ci-IANG!ES <USE 01= OSB OF< SIMILA~ ffiODUCTS INSTALLED FEF< l.c.c.
AFFROVAL I& ADEQUATE:>
B. F'Fi!OVIDE 2x 6LOC'o<:.ING A'f 1-lORI:Z:ONTAL FLYUJOOD PANEL JOINTS.
c. WI-IE~ FL YUIOOD I& r.:.I.PF•l.IED ON 60TI-Il=ACES 01= WALL AND NAIL SPACING
iS LESS TI-tAN lb" o/c. PANEL JOINT6 SI-IALL 6E OFFSET TO !=ALL ON Dli=F'Ei"!ENT
l=~MING MEMBER& OR I"~MiNG! SI-IALL BE 3x 0~ WIDER (0~ 2-2x) AND
NAILS STAGGE~ED ON EAC!-l SIDE.
D. WI-IE~ NAILS ARE &!"'ACED AT 2" ole, TI-lEY SI-IALL 6E STAG:GE~D AND Sx
01'<: WIDER(~ 2-:lx) l=RAMNt.Si: MEMBE~S SI-IALL. BE USED AT ADJOINING
PANEL EDGES.
E. USE l/2 "<l>x11Z>" SILL 60L TS (1" MIN. EMBED INTO CONC~TEJ AT 6'-!Zl" O.C. SP.<l.CIN.a. IN ALL BEAI"!ING WALLS !"OR &'ti"!UCTUF<E& TWO STORIE& 01'<: L.E&S (4'-IZ>" O.C.
&FACING F<E!QUI~D FOR Tl-lr'!.EE-STO~Y ST~CTU~&).
F. US!: TITAN l-ID va"<l>xh"L <I"OR 2x Pl-ATES) OR TITAN l-ID '-"a"<l>x$"L (!'OF< 3xPLATE&, (:2)-2xPL.ATES), ES!'i: I!Z'5>!& IN LIEU 01= SILL 601.. TS AT SAME &FACING TO 2S!Zlll' F.&.l. FDN. WI-IE~ ALLOWED FER LOCAL CODE.
WI-IEF<E ALLOWA6LE &I-lEA~ VALUE& EXCEED 3&1Zl F.L.l=. IN WOOD ST~CTU~ SI-IEA~
WALLS: ALL l=~AMING MEM6E~S ~ECEIVING: EDGE NAILING! !=ROM ABUTTING PANELS
SI-IALL NOT BE LESS TI-IAN A &INGLE 3" NOMINAL MEMElER. IN 51-lEAR WALLS WI-IEF<E
TI-lE TOTAL WALL DESIGN &I-lEA~ DOES NOT EXcEED 6~ FLF., A SINGLE 2" NOMINAL
SILL FLATE IS FE~ITTED 11= ANCI-IO~D BY TWO TIMES TI-lE NUM6E~ 01= BOLT& ~QUIRED BY DESIGN. WOOD ST~CTURAL PANEL JOINT AND SILL PLATE NAILING
&I-IALL BE STAGG:ERED IN ALL CA&ES.
TI-lE FOLLOWING &1-IALL AFFL Y 1=~ SI-IEA~ WALL& GOvE~ED BY WIND ~ SEISMIC
LOADS:
A. TI-lE MINIMUM NOMINAL ANCI-IOR 60L TS DIA. SI-IALL 6E ~/e ".
NOTE TI-IAT TI-llS WILL Re:QUI~ A MINIMUM DISTANCE F~OM TI-lE ENDS 01=
TI-lE SILL PLATES TO 6E 4-316" <AND A MAX. 01= 12").
6. PLATE WASI-IERS (MINIMUM SIZE 01= 3"x3"x1Z>.22'0" SI-IALL 6E USED ON
EACI-I ANcl-l~ 60LT. TI-lE I-IOLE IN TI-lE FI..ATE WASI-IE~ IS FE~ITTED TO
6E DIAGIONALL Y SLOTTED WITI-I A WIDTI-I 01= UF TO 3/16" LA~E~ TI-IAN
TI-lE BOLT DIA. AND A SLOT LENCiiT!-1 NOT TO cXCEED 1 '41 ", F~OVIDED
A STANDA~ CUT WASI-IE~ IS PLACED BETWEEN TI-lE PLATE WA&I-IER
AND TI-lE NUT.
C. NO POWCR DRIVEN FINS SI-IALL 6E USED IN LIEU 01= ANC!-10~ BOLTS
AT TI-lE EOOE OF SL,A6.
--i.
SIMPSON Anchor Designer™
Software
Version 2.0.5154.21
1.Project information
Customer company:
Customer contact name:
Customer e-mail:
Comment:
2. Input Data & Anchor Parameters
General
Design method:ACI 318-08
Units: Imperial units
Anchor Information:
Anchor type: Bonded anchor
Material: A 193 Grade B7
Diameter (inch): 0.625
Effective Embedment depth, het (inch): 10.000
Code report: ICC-ES ESR-2508
Anchor category: -
Anchor ductility: Yes
hmin (inch): 13.13
Cac (inch): 24.29
Cmin (inch): 1.75
Smin (inch): 3.00
Load and Geometry
Load factor source: ACI 318 Section 9.2
Load combination: not set
Seismic design: Yes
Anchors subjected to sustained tension: No
Strength reduction factor for brittle failure, ¢d: 0.5
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: Yes
<Figure 1>
Company: La Costa Engineering I Date: 14/1 0/2015
Engineer: Martell B Montgomery I Page: J 1/4
Project: Gann Residence
Address: 2226 Faraday Ave., Carlsbad, CA 92008
Phone: (760) 931-0290
E-mail: marty montgomery@yahoo.com
Project description:
Location:
Fastening description:
Base Material
Concrete: Normal-weight
Concrete thickness, h (inch): 16.00
State: Cracked
Compressive strength, f c (psi): 2500
4!c.v: 1.0
Reinforcement condition: B tension, B shear
Supplemental reinforcement: Not applicable
Do not evaluate concrete breakout in tension: No
Do not evaluate concrete breakout in shear: No
Hole condition: Dry concrete
Inspection: Continuous
Temperature range: 1
Ignore 6do requirement: Not applicable
Build-up grout pad: No
Base Plate
z
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Ti& 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.corn
SIMPSON
<Figure 2>
®
Anchor Designer™
Software
Version 2.0.5154.21
Recommended Anchor
Anchor Name: SET-XP®-SET-XP w/5/8"0 A193 Gr. 87
Code Report Listing: ICC-ES ESR-2508
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
La Costa Engineering I Date: 14/10/2015
Martell B Montgomery I Page: 12/4
Gann Residence
2226 Faraday Ave., Carlsbad, CA 92008
(760) 931-0290
marty montgomery@yahoo.com
IJl N cO
""""'''"""''""""'"''"'"'""""' ..........
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON Anchor Designer™
Software
Company:
Engineer:
Project:
La Costa Engineering I Date: 14/1 0/2015
Martell B Montgomery I Page: 1314
Gann Residence
Version 2.0.5154.21 Address: 2226 Faraday Ave., Carlsbad, CA 92008 ®
Phone: (760) 931-0290
E-mail: marty montgomery@yahoo.com
••="'"""'"""''''""'"·''"'"
3. Resulting Anchor Forces
Anchor Tension load, Shear load x,
Nua (lb)
1450.0
Sum 1450.0
Maximum concrete compression strain (%o): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 1450
Resultant compression force (lb): 0
Vuax (lb)
0.0
0.0
Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00
Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00
4. Steel Strength of Anchor in Tension(Sec. 0.5.1)
Nsa (lb) rp rj!Nsa (lb)
28250 0.75 21188
5. Concrete Breakout Strength of Anchor in Tension (Sec. 0.5.2)
Nb = kcA...,Jf'cher1.5 (Eq. D-7)
kc A. f'c (psi) her (in) Nb (lb)
17.0 1.00 2500 6.833 15183
0.75rjldrj!Ncb = 0.75rjldrjl (ANcl A Nco) 'Fed,N 'Fc,N'Fcp,NNb (Sec. 0.3.3.3, 0.4.1 & Eq. D-4)
Shear load y,
Vuay (lb)
0.0
0.0
ANc (in2) ANco (in2 'Fed,N 'Fc,N 'Fcp,N Nb (lb)
222.00 420.25 0.751 1.00 1.000 15183
6. Adhesive Strength of Anchor in Tension (AC308 Sec. 3.3)
Tk,cr = Tk,crfshO!MermKsataN.seis
7:k,cr (psi) fshort~term Ksat aN.seis 7:k,cr (psi)
855 1.00 1.00 1.00 855
Nao = 7:k,cr7rdaher(Eq. D-16f)
7:k,cr (psi) da (in) her (in) Nao (lb)
855 0.63 10.000 16788
0.75rjldrj!Na = 0.75rjldrjl (ANal ANao) 'Fed,Na lf/p,NaNao (Sec. 0.3.3.3, 0.4.1 & Eq. D-16a)
ANa (in2) ANaO (in2) 'Ped,Na 'F,o,Na Nao (lb) ¢
137.97 223.60 0.770 1.000 16788 0.65
Shear load combined,
"(Vuax)2+(Vuay)2 (lb)
0.0
0.0
0.75rjldrj!Ncb (lb)
0.65 1469
1945
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
'2:0
SIMPSON Anchor Designer™
Software
Company:
Engineer:
Project:
La Costa Engineering I Date: 14110/2015
Martell B Montgomery I Page: 1414
Gann Residence
Version 2.0.5154.21 Address: 2226 Faraday Ave., Carlsbad, CA 92008
Phone: (760) 931-0290
E-mail: marty montgomery@yahoo.com ...................
11.1nteraction of Tensile and Shear Forces (Sec. 0.7)
Tension Factored Load, Nua (lb) Design Strength, !liNn (lb) Ratio
Steel 1450 21188
Concrete breakout
Adhesive
1450
1450
1469
1945
0.07
0.99
0.75
SET -XP w/ 5/8"0 A 193 Gr. 87 with hef = 10.000 inch meets the selected design criteria.
12. Warnings
Status
Pass
Pass (Governs)
Pass
-Concrete compressive strength used in concrete breakout strength in tension, adhesive strength in tension and concrete pryout strength in
shear for SET-XP adhesive anchor is limit to 2,500 psi per ICC-ES ESR-2508 Section 5.3.
-Designer must exercise own judgement to determine if this design is suitable.
-Refer to manufacturer's product literature for hole cleaning and installation instructions.
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson Company 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
2226 FARADAY AVENUE
CARLSBAD, CALIFORNIA 92008
TEL 760·931-V290 FAX 438-5251
martv_montQomery@yahoo.com
CIVIL • STRUCTURAL
MECH,.,NICA.L• PETROLEUM
STRUCTURAL CALCULATIONS
PROJECT:
ENGINEER:
DATE:
teJ.~!
DESIGN LOADS:
Roof:
18 psfDL
20 psfLL
38 psfTL
Seismic Properties:
GANN RESIDENCE
2388 BOTELLA PLACE
CARLSBAD, CA 92009
MARTELL B. MONTGOMERY
R.C.E. 50344 EXP. 6-30-15
APRIL 7, 2015
MA"\ i ~~ t.o IS
2012 IBC, 2013 CBC
Floor:
10 psfDL
40 psfLL
50 psfTL
Exterior Wall:
15 psfDL
Interior Wall:
8 psfDL
Wind Properties:
Seismic Design Category: D
Occupancy II
Envelope Procedure: 28.1
Exposure B
I= 1 I=l.O
RECEIVED:
MAY 19 201i
CITY OF CJ.\RLSBAO
BUilDING DIVISION
R= 6.5
S5: 1.058
3-s Gust Wind Speed: 110 mph
Pmin= 8 psf Roof
S1: 0.409 16 psf Floor
Site Class: D
Fa: 1.077
Fv: 1.591
SDs: 0.76
Sm: 0.434
2012 NOS MATERIAL SIZE-STRUCTURAL PROPERTIES
DOUGLAS FIR-LARCH (DF, DF-L)
BEAMS & POSTS & LIGHT FRMING RAFTERS,
STRINGERS-#1 TIMBERS-#1 JOISTS-#1 /#2 STUDS-#2
E= 1.6E+06 psi E= 1.6E+06 psi E= 1.6E+06 1.6E+06 psi E= 1.4E+06 psi
f= v 170 psi f= v 170 psi f= v 180 180 psi f= v 180 psi
f= c 925 psi f= c 1000 psi f= c 1500 1350 psi f= c 850 psi
f'Y'= 625 psi f'Y'= 625 psi f'Y'= 625 625 psi f'Y'= 625 psi
ft= 675 psi ft= 825 psi ft= 675 575 psi ft= 450 psi
fb= 1350 psi fb= 1200 psi fb= 1000 900 psi fb= 700 psi
2XMEMBERS 4XMEMBERS 6XMEMBERS
2x4 4x4 6x4
A= 5.3 in2 A= 12.3 in2 A= 19.3 in2
S= 3.1 in3 S= 7.1 in3 S= 11.2 in3
I= 5.4 in4 I= 12.5 in4 I= 19.7 in4
2x6 4x6 6x6
A= 8.3 in2 A= 19.3 in2 A= 30.3 in2
S= 7.6 in3 s = 17.6 in3 s = 27.7 in3
I= 20.8 in4 I= 48.5 in4 I= 76.3 in4
2x8 4x8 6x8
A= 10.9 in2 A= 25.4 in2 A= 39.9 in2
S= 13.1 in3 S= 30.7 in3 s = 48.2 in3
I= 47.6 in4 I= 111.1 in4 I= 174.7 in4
2x10 in2 4x10 6x10
A= 13.9 in3 A= 32.4 in2 A= 50.9 in2
s = 21.4 in4 s = 49.9 in3 s = 78.4 in3
I= 98.9 I= 230.8 in4 I= 362.7 in4
2x12 in2 4x12 6x12
A= 16.9 in3 A= 39.4 in2 A= 61.9 in2
s = 31.6 in4 s = 73.8 in3 S= 116 in3
I= 178 I= 415.3 in4 I= 652.6 in4
2x14 4x14 6x14
A= 19.9 in2 A= 46.4 in2 A= 72.9 in2
s = 43.9 in3 s = 102.4 in3 s = 160.9 in3
I= 290.8 in4 I= 678.5 in4 I= 1066.2 in4
4x16 6x16
A= 53.4 in2 A= 83.9 in2
S= 135.7 in3 s = 213.2 in3
I= 1034 in4 I= 1625.5 in4
STRUCTURAL CALCULATIONS
VERTICAL
FLOOR
FLOOR BEAMS:
FB-1 (KITCHEN):
L= [J:ill ft
w= Lzgj lb/ft
V=wL/2= 3948 lb
M=wl2/8= 10364 ft-lb
TRY ... 5 1/4 x 11 1/4 2.0E PSL
Va= 11420 lb
Ma= 26955 ft-lb
I= 625 in4
LiTL=5wl 4/(384EI)= 0.165 in
1/(LiTJL)= 766 >240? YES
!'iLL =ll(LiTL)/Tl= 0.132 in
1/(LiLJL)= 957 >480? YES
LioL =LiTL-LiLL = 0.033 in USE 51/4 x 111/4 2.0E PSL
FB-2 (KITCHEN/SITTING):
L=~ft V=wL/2= 4888 lb
w= 752 lb/ft M=wl2/8= 15886 ft-lb
TRY ... 5 1/4 x 11 1/4 2.0E PSL
Va= 11420 lb
Ma= 26955 ft-lb
I= 625 in4
LiTL =5wl 4/(384EI)= 0.387 in
1/(LiTL/l)= 404 >240? YES
!'iLL =Ll(LiTL)/TL= 0.309 in
1/(LiLL/l)= 504 >480? YES
LioL =LiTL -!'iLL= 0.077 in USE 5 1/4 x 11 1/4 2.0E PSL
\ h --~~~~~ " --
'. '
2.0E PARAllAM® PSL AllOWABLE DESIGN STRESSES
(100% LOAD DURATION)
Shear modu Ius of elasticity G 125,000 psi
Modulus of elasticity E 2.0 x 106 psi
Flexural stress Fb 2900 psi(1)
Compression perpendicular to grain
650 psi(2)(3) parallel to wide face of strands F c.l =
Compression parallel to grain Fc11 = 2900 psi
Horizontal shear perpendicular
to wide face of strands Fv = 290 psi
(1) For 12-inch depth. For others, multiply by (1J)0·111
(2) F c.l shall not be increased for duration of load.
+
(3) 750 psi for all Eastern Species Parallam® PSL and 1%" thick Western Species Parallam® PSL.
ALLOWABLE DESIGN PROPERTIES (100% LOAD DURATION)
13/4" 2.0E Parallam® PSL
6,530 8,985
3,215 3,805 4,020 4,735
125 210 245 400
5.2 6.2 6.5 7.7
31f211 2.0E PARALLAM® PSL
18"
6,430 7,615 8,035 9,475 10,8~5 12,180
250 415 490 800 1,195 1,700
10.4 12.3 13.0 15.3 17.5 19.7
7" 2.0E PARALLAM® PSL
500 ~30 975 1,600 2,390
20.8 24.6 26.0 30.6 35.0 39.4
Nf0;"~1~}t~(~f~l~s~~ 9,535 10,025 13,800 15,280 20,855 26,840 33,530
.. -••• 4,805 4,935 5,845 6,170 7,275 8,315 9,350
320 375 615 915 1,305
7.8 8.0 9.5 10.0 11.8 13.4 15.1
5%" 2.0E PARALLAM® PSL
Sttf{\R(!bs.f 9,645 11,420 12,055 14,210 16,240 18,270
375 625 735 1,200 1,790 2,550
15.6 18.5 19.5 23.0 26.3 29.5
GENERAL ASSUMPTIONS FOR
NON-TREATED PARALLAM® PSL
• Lateral support is required at all bearing points and along compression edge at
intervals of 24" on-center or closer.
• Parallam® PSL beams are made without c~~ber; therefore, in addition to com-
plying with the deflection limits of the apph~iable building code, other consider-
ations, such as long term deflection under sus~ained loads (including creep),
ponding (positive drainage is essential) and aestretics, must be evaluated.
• Roof members shall either be sloped for drainag10 or designed to account for
load and deflection as specified in the applicabl~ building code.
l
• Reductions applied in accordance with: 1994 USC 1606, 1996 NBC 1606 and
1994 SBC 1604 for floor live load; 1994 UBC 1606, 1996 NBC 1607 and 1994
SBC 1604 for roof live load in non-snow ( 125%) conditions.
• 3%" members may be two pieces of 1%" or a single 3%" width beam.
5%" members may be three pieces 1%", one piece 1%" with one piece 3%",
or a single 5%" width beam.
7" members may be two pieces 1%" around one piece 3112", two pieces 3%",
.or a single 7" width beam.
See pages 16 and 17 for multiple member beam connections. -
FB-3 (STAIRJDINING):
L=~ft V=wL/2= 1672 lb AR=1.5(V)/fv= 13.93 in2
w= 743 lb/ft M=wL2/8= 1881 ft-lb SR=M/(fb *Co *CFl= 22.8 in3
Co= 1
TRY ... 4 X 12 CF= 1.1
I= 415.3 in4 LiLL =LL(LiTL)/TL= 0.005 in
LiTL =5wL 4/(384EI)= 0.010 in 11( f:.LL/L )= 10626 >480? YES
1/(f:.TL/L)= 5234 >240? YES f:.oL =f:.TL-f:.LL = 0.005 in I USE 4x 12
FB-4 (SITTING/DINING):
L=~ft V=wL/2= 5118 lb
w= 853 lb/ft M=wL2/8= 15354 ft-lb
TRY ... 5 1/4 x 11 1/4 2.0E PSL
Va= 11420 lb
Ma= 26955 ft-lb
I= 625 in4
LiTL =5wl 4/(384EI)= 0.318 in
1 /(f:.TL/L)= 452 >240? YES
LiLL =LL(LiTL)/TL= 0.255 in
1/(f:.LL/L}= 565 >360? YES
f:.oL=f:.TL-f:.LL = 0.064 in USE 5 1/4 x 11 1/4 2.0E PSL
1sT FLOOR HEADERS:
CHECK (E) REDUCED-SPAN HEADER (FAMILY RM):
L=~fl V=wU2= 833 lb AR=·1.5(V)/fv= 6.94 in2
w= 666 lb/ft M=wL2/8= 520 ft-lb SR=M/(fb *Co *CFl= 5.3 in3
c-o-1
TRY ... 4x6 CF= i .3
I= 48.5 . 4 m LiLL =LL(LiTL)/TL= 0.004 in
LiTL =5wl 4/(384EI)= 0.008 in 1/(f:.LL/L)= 8074 >480? YES
1 /(f:.TL/L)= 3977 >240? YES LoL =LiTL-LiLL = 0.004 in I USE MIN. 4x6
HEADER (KITCHEN):
L=~ft
w= ~ lb/ft
TRY ... 4x6
I= 48.5 in4
6rL =5wl 4/(384EI)= 0.024 in
1/(LrL/L)= 1739 >240?
HEADER (SITTING):
L=~ft
w= 555 lb!ft
V=wl/2=
M=wl2/8=
YES
V=wl/2=
M=wl2/8=
TRY ... 3 1/2 x 11 1/4 2.0E PSL
Va= 7615 lb
Ma= 17970 ft-lb
I= 415 in4
LrL =5wl 4/(384EI)= 0.312 in
1/(LrL/L)= 462 >240? YES
6LL=LL(6rL)ITL= 0.163 in
1/(6LL/l)= 883 >480? YES
6oL=6TL-6LL= 0.149 in
HEADER (DINING):
l=@lt V=wl/2=
w= 555 lb/ft M=wl2/8=
TRY ... 4x8
I= 111.1 in4
LrL =5wl 4/(384EI)= 0.044 in
1/(Lr)L)= 1367 >240? YES
971 lb AR=1.5(V)/fv= 8.09 in2
850 ft-lb SR=M/(fb *Co *CFl= 8.7 in3
Co= 1
CF= 1.3
6LL =LL(6TL)/TL= 0.012 in
l/{6LL/l)= 3531 >480? YES
LoL =LrL -6LL = 0.012 in I USE 4x6
3330 lb
9990 ft-lb
USE 3 1/2 x 111/4 2.0E PSL
1388 lb AR=1.5(V)/fv= 11.56 in2
1734 ft-lb SR=M/(fb*Co *CFl= 17.8 in3
Co= 1
CF= 1.3
6LL =LL(6rL)/TL= 0.023 in
l/(6LL/l)= 2596 >480? YES
LoL =6rL-6LL = 0.021 in I USE 4x8
7
HEADER (DINING):
L=@ft V=wl/2= 1006 lb AR=1.5{V}/fv= 8.38 in2
w= 503 lb/ft M=wl2/8= 1006 ft-lb SR=M/(fb *Co*CFl= 10.3 in3
Co= 1
TRY ... 4x6 CF= 1.3
I= 48.5 in4 .6.LL =LL(.6.TL)/TL= 0.020 in
.6.TL =5wl 4/(384EI)= 0.037 in 11(.6-LL/l)= 2443 >480? YES
1/(.6-TL/l)= 1286 >240? YES .6.oL :.6,TL -.6,LL = 0.018 in I USE 4x6
HEADER (GARAGE/ENTRY):
L=@fl V=wl/2= 1115 lb AR=1.5(V)/fv= 9.29 in2
w= 743 lb/ft M=wl2/8= 836 ft-lb SR=M/(fb *Co *CFl= 8.6 in3
Co= 1
TRY ... 4x6 CF= 1.3
I= 48.5 in4 .6.LL =LL(.6.TL}/TL= 0.009 in
.6.TL =5wl 4/(384EI)= 0.017 in 11(.6-LL/l)= 3920 >480? YES
1/(.6-TL/l)= 2063 >240? YES .6.oL =.6.TL -.6,LL = 0.008 in I USE 4x6
Posts
Example Post Design for 4 x 4 of Length 10'
For Douglas Fir-Larch per NDS 2005,
E=l.6x106 psi (for 2-4" wide)
Fc=l350 psi (for 2-4" wide)
L=lO'
d=3.5"; h=3.5"
Ke=l
L.,/d= K/L /d=l *10'(12 in/ft)/3.5"=34.3
IfL.,Id:::;;ll, thenF'c=Fc
If 11 <L.,Id:::;;K, then F' c=Fc[l-l/3(L.,/d)/K))'1
IfK <L.,/d:550, then F' c=0.3E/(L.,idi
K=0.67l(E/Fc)112
=0.671 (1.6xl 06 psi/1350 psi)112
=23.1
23.1 <34.3 :550, F' c=0.3(1.6xl 06 psi)/34.32=408.3 psi
Pa=F'c(d)(h)=408 psi(3.5"/=5002lb
Allowable Load (lb)
Length Cross-section (in x in)
L (ft) 4x4 4x6 4x8 6x4
2 16538 25988 34256 25988
3 16538 25988 34256 25988
4 15853 24911 32838 25988
5 14866 23360 30793 25988
6 13071 20539 27075 25094
7 10208 16042 21146 24332
8 7813 12282 16190 23164
9 6175 9704 12792 21465
10 5002 7860 10361 19094
11 4134 6496 8563 16042
12 3474 5459 7195 13479
13 2960 4651 6131 11485
14 2552 4010 5286 9903
15 2223 3494 4605 8627
16 1954 3070 4047 7582
17 1731 2720 3585 6716
18 1544 2426 3198 5991
19 1386 2177 2870 5377
20 1251 1965 2590 4853
21 1134 1782 2350 4401
22 1033 1624 2141 4010
s
6x6
30250
30250
30250
30250
29679
29193
28447
27361
25847
23804
. 21120
18049
15562
13556
11915
10554
9414
8449
7626
6917
6302
Foundations
Soil bearing pressure (Ps ): 1 000 psf
Check New/Exist. Continuous 2-Storv Footing
w=l 883llb/ft
Story= 2
Width 0.940 ft
B=(w/Ps)112= 11.3 in
B=c=J]lin
D=c:==min
As=pbd= 0.26 in2 Try (2)-#4:
Table 1806.2, CBC 2013
0.40 in2 > 0.26 in2
USE EXIST. 12 W x 18 D continuous footing, 2500 psi
wl (2)-#4 Top & Bottom
Check New Point Load on Exist. 2-Story Continuous Footing
B= 12 in
4 in Pa=W*B*Ps= 3667 lb
18 in P max= 3948 < 3667 lb OK
Spread Footings
B=v(P/Ps) As=pbd
PAD# p Footing Size As(in2) Reinforcement
1 6250 30 w X 12 D * 0.49 (3)-#4 E.W.
2 9000 36 w X 1Z D * 0.97 U:?)·#4 E.W.
3 9000 36 w X 18 D 0.97 (5)-#4 E.W.
4 14063 45 w X 18 D 1.22 (6)-#4 E.W.
* -"Underpinned" Foot1ng
Lateral Calculations
Wind Loads -(Envelope Procedure) 28.1
Roof slope= I 51/12
18.4 psf
P=qh[(GCpf) -(GCp;)] =
@Roof:
@Walls:
Wind Distribution:
k= z
10.0 mll
17.5 Q§f
16 psf Walls 28.4.4
8 psf Roof
2nd Roof-Main House/ Remodel Area
wp=(5.75')(10.0)+(8'/2)(17.5)= 128 lb/ft
Wpmin=(5. 75')(8)+(8'/2)(16}= 110 lb/ft
Floor-Main House/ Remodel Area
wp=(8'/2+1.0'+8'/2)(17.5)= 158 lb/ft
Wpmin=(8'/2+1.0'+8'/2)(16) = 144 lb/ft
1st Roof-Main House/ Remodel Area
Wp=(11.5')(1 0.0)+(8'/2)(17.5)= 185 Jb/ft
Wpmin=(11.5')(8)+(8'/2)(16)= 156 lb/ft
0.18 Enclosed Table26.11-1
0.54 Surface 1 Fig. 28.4-1 Case A
-0.45 Surface 2 Fig. 28.4-1 Case A
0.77 Surface 1 E Fig. 28.4-1 Case A
-0.72 Surface 2E Fig. 28.4-1 Case A
0.4 Surface 5 Fig. 28.4-1 Case B
0.61 Surface 5E Fig. 28.4-1 Case B
0.70 Table 28.3-1 EXP.B
1.0 26.8.2
0.85 Table 26.6-1
110 mph, 3s Gust, Fig. 26.5-1A
KEY MA:y>
t:.-'1-. ,~\'fo\.~ vJfiU...
F-'1· ~jVIl> S't'Ot!.-l.o\ Wlfr\.1...
(~) «~(2.0-F-\1" s~~~ w;lt\-\..
( t-:l) ):.N\U. \..i tJ~
Seismic Loads
Ss= 1.058
S1= 0.409
Site Class: 0
F= a 1.077
F= v 1.591
R= 6.5
I= 1.0
Floors: 2
SMs=F aSs= 1 .140
SM1=FvS1= 0.651
Sos=2/3SMs= 0.760 SDC: D
So1=2/3SM1= 0.434
SIMPLIFIED DESIGN PROCEDURE (ASCE 712.14)
E=Eh+Ev
E=Eh-Ev
Eh=QE=V
(For load comb. 5 & 6 ASD)
(For load. comb 8 ASD)
Ev=0.2S05D= 0 for E acting in plane of diaphragm/base shear
Seismic Base Shear (per ASCE 12.14.8.1)
V=FS05W/R F= 1.1
R= 6.5
V= 0.129 W
Vertical Distribution (per ASCE 12.14.8.2)
F x=FS0 s/R*wx
F= 0.129 Wx
Design Maps Srunmary Report
i\IIJSGS Design Maps Summary Report
User-Specified Input
Report Title Gann Residence
Fri AprillO, 2015 03:19:32 UTC
Building Code Reference Document ASCE 7-10 Standard
http :1 I ehp4-earthquake.cr. usgs.gov/ designmaps/us/ srunmary. php?templ. ..
(which utilizes USGS hazard data available in 2008)
Site Coordinates 33.08373°N, 117.25626°W
Site Soil Classification Site Class D -"Stiff Soil"
Risk Category !/II/III
E=====::::::J 2mi 5000m
USGS-Provided Output
s. = 1.058 g
51= 0.409 g
SMs= 1.140g
SMl = 0.651 g
Sos = 0.760 g
So1 = 0.434 g
For infonnation on how the 55 and 51 values above have been calculated from probabilistic (risk-targeted) and
detenninistic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
MCE, Response Spectrum
O.SB
l.GO l.Bf.l 2.0D
Period~ T (sed
For PGAM, TL, CR5, and CR1 values, please view the detailed report.
Design Response Spectrum
Q.J1J 0.40 IJ.GC! O.BO l.QO 1.20 1.4.0 l.GO LSO 2.otl
Period, T {sed
Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of
the data contained therein. This tool is not a substitute for technical subject-matter knowledge.
Seismic Distribution
DLroor 18 psf
DLfloor=
DLwallext=
LineA
2ND ROOF
Lnne=
Hwau=
FLOOR
Lnne=
Hwau=
Line 2
2ND ROOF
Lnne=
Hwau=
FLOOR
Lnne=
Hwau=
Line 3
2ND ROOF
Lnne=
Hwau=
FLOOR
Lnne=
Hwau=
10 psf
15 psf
B" ft
B" ft
~ft ft
~ft ft
B" ft
B" ft
wR= (38')18= 684 lblft WIND
Ww= 2(8'/2)15= 120 lblft GOVERNS
v = 0.129(684+120)= 103 lb/ft
wF= (38')1 0= 380 lblft WIND
Ww= 2(8'/2+8'/2)15= 240 lb/ft GOVERNS
v = 0.129(380+240)= 80 lb/ft
wR= (27.5')18= 495 lb/ft WIND
Ww= 2(8'/2)15= 120 lblft GOVERNS
v = 0.129(495+120)= 79 lb/ft
wF= (27.5')10= 275 lb/ft WIND
Ww= 2(8'/2+8'/2)15= 240 lb/ft GOVERNS
v = 0.129(275+240)= 66 lb/ft
wR= (12')18= 216 lblft WIND
Ww= 2(8'/2)15= 120 lblft GOVERNS
v = 0.129(216+120)= 43 lb/ft
wF= (12')10= 120 lb/ft WIND
Ww= 2(8'/2+8'/2)15= 240 lb/ft GOVERNS
v = 0.129(120+240)= 46 lb/ft
Diaphragm/Shear Loads
RA 2R= 0.6{128 lb/ft)(27.5'/2)=
RA F= 0.6(158 lb/ft)[{27.5'/2)=
Use Load Combination 2.4.1 ASCE 7-10: #5:
D + (0.6W or 0.7E) for Wind/Seismic Loads
~lb
~lb
R2 2R/1R= 0.6{[(128 lb/ft)(38'/2)(12'/27.5')+{185 lb/ft)(50'/2)(15.5'/27.5')](27.5'/52')}=
1 1164jlb
R2 F= 0.6{{158 lb/ft){(38'/2){12'/27.5')+(24'/2)(15.5'/27.5')](27.5'/52')}-
R3 2R= 0.6(128 lb/ft)(14'/2)=
R3F= 0.6(1581b/ft)(14'/2)=
Drag Loads
FLOOR:
Line 2: (27 lb/ft){ 16.5 ft)= 4461b
...-, -75--.511b
~lb c=Bib
USE ST 6224
28 lb/ft
34 lb/ft
42 lb/ft
27 lb/ft
45 lb/ft
55 lb/ft
SHEAR WALLS: Seismic: Use Load Comb.#8 2.4.1 ASCE 7-05 (12.14.3.1.3)
(0.6D-0.14S0sD) = 0.49 D
Wind: Use Load Comb.#? 2.4.1 ASCE 7-05
LINE
Distribution:
Fir. W# H' W#H'
2 1056 17 17952
1 1304 8 10432
Tot. O.T.M.= 28384 ft-lb
(0.6D)
A WALLS:
OTM=
RM=
UPLIFT=
1 Fir. v= 143 lb/ft Use Type._l __ 1 __ 1wall
Check Perforated Shear Wall Design:
8'-0" NET (LINE A, 11 '-6" WALL @1ST FLOOR)
WALL UNIT SHEAR = (10561b + 13041b)/16.5' = 1431b/ft
6881 ft-lb
1080 ft-lb 0.6[(2'/2 +1.5')(18)+(8')(15)
1450 lb +(12'/2)(10)](4')2/2
USE HDU2 w/ RETROFIT 5/8" a.b. x 1 0"
EMBED. INTO EXIST. CONC. USE
SET -XP EPOXY, ESR-2508, FOLLOW
ALL MANUFACTURER RECOMMENDATIONS.
PIER UNIT SHEAR= (143 lblft)(11.5')/(6' + 2') = 206 lb/ft GOVERNS
DRAG FORCE= 3.5'(206-143) = 2191b
EFFECTIVE h/w= 3.5'/2'= 1. 75: 1 OK USE CS16 STRAP (Lmin=4')
16
LINE 2
Distribution:
Fir. W# H' W#H'
2 1164 17 19788
1 755 8 6040
Tot. O.T.M.= 25828 ft-lb
WALLS:
I:Ls.w.=
OTM=
RM=
UPLIFT=
ft. exist. wall)
25828 ft-lb
12456 ft-lb 0.6[(34'/2)(18)+(8')(8)
1274 lb +(1.33'/2)(10)](10.5')2/2
1 Fir. v= 183 lb/ft Use Typel ... __ 1 _ __.lwall
LINE
Distribution:
Fir. W# H' W#H'
2 538 17 9146
1 664 8 5312
Tot. O.T.M.= 14458 ft-lb
3
USE HDU2 w/ RETROFIT 5/8" a.b. x 1 0"
EMBED. INTO EXIST. CONC. USE
SET -XP EPOXY, ESR-2508, FOLLOW
ALL MANUFACTURER RECOMMENDATIONS.
WALLS:
Uplift at 1st Floor{ 12 ft. exist. wall)
I:Ls.w.= 12 ft
OTM= 14458 ft-lb
RM=
UPLIFT=
10134 ft-lb 0.6[(14'/2 +1.5')(18)+(5')(15)
360 lb +(1.33'/2)(1 0)](12')2/2
1 Fir. v= 100 lb/ft Use TypeiL. __ 1_ ...... 1Wall
Check Perforated Shear Wall Design:
8'-0" NET (LINE 3, 12'-0" WALL @1ST FLOOR)
WALL UNIT SHEAR = (5381b + 6641b)/12' = 100 lb/ft
USE HDU2 w/ RETROFIT 5/8" a.b. x 1 0"
EMBED. INTO EXIST. CONC. USE
SET -XP EPOXY, ESR-2508, FOLLOW
ALL MANUFACTURER RECOMMENDATIONS.
PIER UNIT SHEAR= (100 lb/ft)(12')/(4' + 4') = 150 lb/ft GOVERNS
DRAG FORCE= 4'(150-100) = 200 lb
EFFECTIVE h/w= 5'/4'= 1.25: 1 OK USE CS16 STRAP (Lmin=4')
,.------
SHEAR SCHEDULE ~V. FER 2!Z113 CALli=. 6LOO. CODE (II!Z1112!Z114)
D WALL NAILING !=OUNDATION SI-!EAR TRANSI=ER D
s.w. SI-!EAR WALL MATERIAL NAIL PANEL INTER V2"<i>xi!Zl" MIN. MIN. BOTTOM NAILS AND A-3~ TJI BLK'c:l: MICRO LAM RIM JST teLK'G e.w. WALL VALUE EDGE $PACE A.6.SPAC'G PLATE NAILING 6LOCKS SPACING TO PLATES WI SIMFSON CLIPS WALL
1 2E>~ 31$" CDX OR OS6 FLYWD ** ecl ,., .. 12" 32" ole. lta.cl "'I~" ole l6cl e 6" ole 16" 16cl «> 6" ole. A35> «> 16" ole 1
2 35~ 31€>" CDX OR OS6 PL YWD ** 8cl 4" 1:2" 24" ole IE>cl e lrz>" ole 16cl «> 4" ole 12" l6cl e 6" ole A3!io e 12" ole 2
*3 4W 318" CDX OR 056 F'L YWD, * * 8cl 3" 12" 24" ole. ::>/Ei>"x6' l-AGS 16" IE>cl e 4" ole. 8" 16d «> 6" ole. A3& «> 8" ole. *3 3 x SILL ole. <PREDRILL> STAGGERED
*4 641Z1 31&" CDX OR OS6 FL YWD, ** ecl 2" 12" 12" ole 318"xi&' LAGS 12" li&d 11> 4" ole 8" 16d e 6" ole. A35 e 8" ole *4 3 x SILL ole. (PI"!fDRILL.> STAC!ME~D
*!? 111Z1 1/2" CDX OR 0&6 F'L YWD, *** l~cl 2" 12" 8" ole. 3/8"x6' LAGS '1!1" IE>cl -e 4" ole. 10" li!Od «> 6" ole. A:.& e 6" ole *!? 3 x SILL ole. <PREDRILL) ST AGc:l:ERED
*b 611Zl 1/2" PL YWD, &T~C I *** l!Zld 2" 12" e" ole. 3/&"xl&' LAGS e" IE>d "'4" ole E>" ll&d «> E>" ole. A3& e 6" ole. *b 3 x SILL ole. (F'RlEDRILLJ STAGc:l:ERED
10 18el 118" STUCCO WI FAPER 6KD. 11 c:l:A. 1-112" I&" I&" 48" ole. l6d "'11Z1" ole. 16cl e 8" ole 24" l6d «> 6" ole. A3& <~> 24" ole. 10 LATH 114" FURRING MIN.> 1116" I-lEAD -
SHEAR SCHEDULE NOTES
* FAAMING AT ADJOINING PANI:L EDGES SI-IALL NOT Be LESS TI-!AN 3x OFi'
WIDER AND NAILS SI-IALL BE STAGc:l:ERED. ** USE ed<:H'2'x~.l31" COMMON, 2V2"x!Z1.113 GALV. 60X) * * * USE lrz>d(3"x!Zl.148" COMMON, 3"x~.128" GAL V. 60X)
.A. USE CDX, CC, Ofii! SRD WI EXT. GLUE IN LIEU OF STRUCTUI'i!AL FL YWOOD.
THESE VALUES ARE FOR DOUG. FIR. OTHER LUM6ER SFECIE& MAY REQLIIRE
CI-IANGES (USE OF OS6 OR SIMILAR PRODUCTS INSTALLED FER I.C.C.
AFF'Fi!OVAL IS ADEQUATE>
e. F'Fi!OVIDE 2x 6LOCKING AT HORIZONTAL PLYWOOD PANEL JOINTS.
C. WI-IE:RE PLYWOOD IS APPLIE:D ON 60TH !=ACES OF WALL AND NAIL SPACING
IS LESS THAN 6" ole. PANEL JOINTS SI-IALL BE OFFSET TO !=ALL ON Dli=i=EI'<!eNt
FRAMING MEM6ERS OR i=RAt11NG SI-IALL SE 3x OR WIDER (Ofii! 2·2>() AND
NAILS StAGGeRED ON eACH SIDE.
D. Wl-leRE NAIL€> ARE SF ACED AT 2" ole., TI-leY SHALL ee ST AGGE~D AND 3x
OR WIDER (OR 2-2x) FRAMNG MEM6ERS SHALL 6E USED At ADJOINING
FANEL EDGES.
E.
i=.
USE va"<l>x11Z1" SILL BOLTS (1" MIN. EMBED INTO CONCRETI:V AT 6'-!Z1" O.C. &FACING
IN ALL SEARING WALLS l=OR ST~CTURES TWO STOF<!IES OR LESS ( 4'-!Zl" O.C. SPACING REQUIRED FOR THREE-STORY ST~CTURE&>.
USE TITAN l-ID V2"<l>x6"L (i=O~ 2x PLATES> Ofii! TITAN l-ID Va"4'x!!!o"L <FOR .3xi"'LATeS, (2J-2xPLATES>, ESF!! 11Z>!io6 IN LIEU Oi= SILL eoL TS AT SAME SPACING TO :25IZIIZ' 1"'.6.1.
FDN. WI-IERE ALLOWED F'EFC LOCAL CODE.
WI-IEI'!!E ALLOWABLE &I-lEAR VALUES EXCEED 35!Zl F'.L.F. IN WOOD ST~CTURAL SI-IEAR
WALLS: ALL i=F<!AMING MEM6ERS RECEIVING EDGE NAILING !=ROM A6UTTING PANELS
SHALL NOT 6E Le&s TI-!AN A SINGLE 3" NOMINAL MEMSI:R. IN SI-IEAR WALLS WI-IERE
TI-lE TOTAL WALL DESIGN SHeAR DOES NOT EXCEED 6~ P.L.F., A SINGLE 2" NOMINAL
SILL PLATE IS PERMITTE:D li= ANCHORED 6Y TWO TIME:& TI-lE NUM6ER OF 60LTS
Fi'EGlUIRED ey DESIGN. WOOD ST~CTURAL PANEL JOINT AND SILL FLATE NAILING
SHALL 6E ST AOOERED IN ALL CASES.
TI-lE !=OLLOWING SHALL APPLY FOR 61-!EAI'!! WALLS GOvERNE:D 6Y WIND OR SEISMIC
LOADS:
A. TI-lE MINIMUM NOMINAL ANCI-IOR 60LTS PIA. &1-!ALL 6E &-&".
NOTE THAT TI-llS WILL REQUIRE A MINIMUM DISTANCE FROM THE ENDS OF
TI-lE SILL PLATES TO 6E 4-31!!!>" <AND A MAX. OF 12").
6. PLATE WASI-IERS <MINIMUM SIZe OF 3"x3"x!Z1.22S" &1-!ALL 6E USED ON
EACH ANCHOR BOLT. TI-lE I-IOLE IN THE FLATE WASHER IS PERMITTED TO
SE DIAGONALLY SLOTTED WITH A WIDTI-l Oi= UF TO 3116" LA1'<GER TI-!AN
TI-lE SOL T DIA. AND A SLOT LENGTH NOT TO EXCEED 1 3~ ", F'Fi!OVIDED
A STANDARD CUT WASHER IS PLACE:D 6ETWEEN TI-ll: PLATE WASHER
AND THE NUT.
C. NO POUJEI'<! DRIVEN PIN& SI-IALL eE USED IN LIEU Oi= ANCHOR 60L TS
AT TI-le eDGE OF &LA6.
-~
SIMPSON
®
Anchor Designer™
Software
Version 2.0.5154.21
1.Project information
Customer company:
Customer contact name:
Customer e-mail:
Comment:
2. Input Data & Anchor Parameters
General
Design method:ACI 318-08
Units: Imperial units
Anchor Information:
Anchor type: Bonded anchor
Material: A 193 Grade B7
Diameter (inch): 0.625
Effective Embedment depth, het (inch): 10.000
Code report: ICC-ES ESR-2508
Anchor category: -
Anchor ductility: Yes
hmin (inch): 13.13
Cac (inch): 24.29
Cmin (inch): 1.75
Sm;n (inch): 3.00
Load and Geometry
Load factor source: ACI 318 Section 9.2
Load combination: not set
Seismic design: Yes
Anchors subjected to sustained tension: No
Strength reduction factor for brittle failure, 1/Jd: 0.5
Apply entire shear load at front row: No
Anchors only resisting wind and/or seismic loads: Yes
<Figure 1>
Company: La Costa Engineering I Date: 14/1 0/2015
Engineer: Martell B Montgomery I Page: 11/4
Project: Gann Residence
Address: 2226 Faraday Ave., Carlsbad, CA 92008
Phone: (760) 931-0290
E-mail: marty montgomery@yahoo.com
,,.~.o;:;; ., ·-~· "''-'' ' -~"-~''"'' '"'~"" ""~'"' "''"'"'""""" '"""'~-~-~··•"'""'"' "'"''" ,. _,~-~--.,-·-~~· -
Project description:
Location:
Fastening description:
Base Material
Concrete: Normal-weight
Concrete thickness, h (inch): 16.00
State: Cracked
Compressive strength, f c (psi): 2500
41c.v: 1.0
Reinforcement condition: B tension, B shear
Supplemental reinforcement: Not applicable
Do not evaluate concrete breakout in tension: No
Do not evaluate concrete breakout in shear: No
Hole condition: Dry concrete
Inspection: Continuous
Temperature range: 1
Ignore 6do requirement: Not applicable
Build-up grout pad: No
Base Plate
z
---y
" "'"~~"'""'=' '-"''-'. .,,,~ '"''"'""'"'"'" "''" ·"
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson Strong--Tie Company 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON
<Figure 2>
Anchor Designer™
Software
Version 2.0.5154.21
Recommended Anchor
Anchor Name: SET-XP®-SET-XP w/ 5/8"0 A193 Gr. 87
Code Report Listing: JCC-ES ESR-2508
Company:
Engineer:
Project:
Address:
Phone:
E-mail:
La Costa Engineering _I Date: 14/10/2015
Martell B Montgomery I Page: 1214
Gann Residence
2226 Faraday Ave., Carlsbad, CA 92008
(760) 931-0290
marty montgomery@yahoo.com
. ····· '• ....•. ····· "'"'' .•...... ""'""
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Strong-5956 W. las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
SIMPSON Anchor Designer™
Software
Company:
Engineer:
Project:
La Costa Engineering I Date: 14/1 0/2015
Martell B Montgomery I Page: 13/4
Gann Residence
Version 2.0.5154.21 Address: 2226 Faraday Ave., Carlsbad, CA 92008
Phone: (760) 931-0290
E-mail: marty montgomery@yahoo.com
,,.,,_,, ''"''"'''"''''''''''''''''"'"''''''"'' "'' ,,,.,,_,,
3. Resulting Anchor Forces
Anchor Tension load, Shear load x,
Nua (lb)
1450.0
Sum 1450.0
Maximum concrete compression strain (%o): 0.00
Maximum concrete compression stress (psi): 0
Resultant tension force (lb): 1450
Resultant compression force (lb): 0
Vuax (lb)
0.0
0.0
Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00
Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00
4. Steel Strength of Anchor in TensionCSec. 0.5.1)
Nsa (lb) rjJ rpNsa (lb)
28250 0.75 21188
5. Concrete Breakout Strength of Anchor in Tension (Sec. 0.5.2)
Nb = koJ.,--Jf'oher1.5 (Eq. D-7)
ko /l f'c (psi) her (in) Nb (lb)
17.0 1.00 2500 6.833 15183
0.75rpdt/JNob = 0.75rpdt/J (ANal ANoo) 'Fed,N 'Fo,N 'Fop,NNb (Sec. 0.3.3.3, 0.4.1 & Eq. D-4)
Shear load y,
Vuay (lb)
0.0
0.0
A No (in2) A Nco (in2 'Fed,N 'Fc,N 'Fop,N Nb (lb)
222.00 420.25 0.751 1.00 1.000 15183
6. Adhesive Strength of Anchor in Tension (AC308 Sec. 3.3)
'tk,cr = Tk,crfshorMermKsataN.seis
Tk,or (psi) fshort-term Ksat aN.seis Tk,or (psi)
855 1.00 1.00 1.00 855
Nao = Tk,orndaher(Eq. D-16f)
Tk,or (psi) da (in) her (in) Nao (lb)
855 0.63 10.000 16788
0.75rpdrpNa = 0.75tjJdrjJ (ANal ANao) 'Fed,Na 'Fp,NaNao (Sec. 0.3.3.3, 0.4.1 & Eq. D-16a)
ANa (in2) ANaO (in2) 'Fed,Na 'Fp,Na Nao (lb) rjJ
137.97 223.60 0. 770 1.000 16788 0.65
0.65
0.75rpdrpNa (lb)
1945
'""'"""-'' -------------
Shear load combined,
-f{Vuax)2+(Vuay)2 (lb)
0.0
0.0
0.75rjJdrpNob (lb)
1469
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com
Anchor Designer™
Software
Company:
Engineer:
Project:
La Costa Engineering I Date: 14/10/2015
Martell 8 Montgomery I Page: 14/4
Gann Residence
Version 2.0.5154.21 Address: 2226 Faraday Ave., Carlsbad, CA 92008 ®
Phone: (760) 931-0290
E-mail: marty montgomery@yahoo.com
-' ''" •OC•c" "" '"''""'" ~.-~"'' "'""""' '"•"'•'" h" '"'''~-'"""'"'-""~•-• ·~••-' "'~ """-"' "'" ·~··•·•-•~•"•"''"'"'",
11. Interaction of Tensile and Shear Forces (Sec. D.7)
Tension Factored Load, Nua (lb) Design Strength, 11lNn (lb) Ratio
Steel 1450 21188
Concrete breakout
Adhesive
1450
1450
1469
1945
0.07
0.99
0.75
SET-XP w/5/8"0 A193 Gr. 87 with hef = 10.000 inch meets the selected design criteria.
12. Warnings
. '"' '""'"~ ...... ~. -"-'""'
Status
Pass
Pass (Governs)
Pass
-Concrete compressive strength used in concrete breakout strength in tension, adhesive strength in tension and concrete pryout strength in
shear for SET-XP adhesive anchor is limit to 2,500 psi per ICC-ES ESR-2508 Section 5.3.
-Designer must exercise own judgement to determine if this design is suitable.
-Refer to manufacturer's product literature for hole cleaning and installation instructions.
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility.
Simpson 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com