HomeMy WebLinkAbout2392 APPIAN RD; ; CB931074; PermitI ! i ~ I I i ! i ! i 1 'i 11/02/93 15:OO Job Address: 2392 APPIAN RD Page 1 of 1 Permit Type: RESIDENTAL ADD/ALT Parcel No: 167-370-05-00 Lot#: Valuation: Construction Type: VN Occupancy Group: R3 Reference#: Description: 192 SF ADDITION BUILDING PERMIT Suite: 17,088 Permit No: CB931074 Project No: A9301506 Development No: 4546 11/02/93 OOO1 01 02 C-PRMT 211.00 Applied: 10/01/93 Stat.us : ISSUED Apr/Issue: 11/02/93 Appl/Ownr : NEUSCHAFER, DAVID 619 726-210 Entered By: DC VISTA, CA 92083 529 HUTCHISON **li Fees Required Adjustments: Fees : Total Fees: """"""""""" Fee description """"""""" Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for, Elec Enter "Y" for Remo x ELECTRICAL TOTAL INCORPORATED Cred i t s x** _"""""""" , 00 k23,OO 211.00 Ext fee Data """"""""_ 189. 00 123.00 314.00 2.00 10.00 Y 20.00 10.00 Y P S&&6/ City of Carlsbad Building Departmt 2075 Las Pallso Dr., Carlsbad, U 92009 (619) UB-1161 IYYB A - U COmmerclal U New Burldrng RTenant Improvement B - 0 Industrial 0 New Building WTenant Improvement C - 0 Residential 0 Apartment OCondo 0 Single Family Dwelling AAdditioWAlteration 0 Duplex 0 Demolition 0 Relmtion 0 Mobile Home 0 Electrical 0 Plumbing 0 Mechanical OPool 0 Spa ORetaining Wall OSolar OOther 2 PRWEIXINFORMA'IION .., < ,.e i, .. , ..., :. . - . .. ... . ,. .. .. . .I ,I FOR OPmCE USE ONLY CITY STATE ZIP CODE DAY TJXEPHONE STATE LIC. X Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified Workers' compensation Ueelaratlon: 1 hereby atllrm that 1 have a certtlkcate 01 consent to selt-Insure lssued by the Olrector ot lndustnal by the Dimtor of the insurer thereof filed with the Building Inspection Department (Section 38W, lab. C). 0 I, as owner of the property or my employees with wages as their sole compensation. will do the work and the structure is not intended or offered for Sale (Sec. 7044, Business and Professions Code: The Contractor's License law dm not apply to an owner of property who builds or improves thereon, and who dm such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden 0 I, as owner of the property, am exclusivelycontracting with licensed contractors to consmet the project (Sec. 7044, Business and Professions of proving that he did not build or improve for the purpose of sale.). Code: The Contractor's license law dm not apply to an owner of properry who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). 0 I am exempt under Section Business and Professions Code for this reason: any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair provisions of the Contractor's license Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [SSOO]). SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Prfsley-Tanner Hazardous Substance Account Act? Is the applicant or future building meupant required to obtain a permit from the air pollution control district or air quality management dkuict? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? IPANYOFTHEANSWERSAREYE$AFINU~~TEOFOOCUPANCYMAYNOTBElSSUEDAPlWJULY1,1989UNIPSS~AWUCANT 0 YES 0 NO 0 YES 0 NO 0 YES 0 NO HAS m OR IS MEETING THE RFQ~EMENIS OF THE OFFICE OF ~~I~GENCY SERVI~ AND THE AIR mmoN mm DISIRKX. I hereby altlrm that there IS a Construction lendmg agency tor the perlormance ot the work tor whlch thls permit IS lssued (sff 30- Lode). LENDER'S NAME LENDER'S ADDRESS 1 cert~ that I have read the appllcatmn and state that the above mtarmatlon IS correct. I agree to comply wlth all Clty ordmances and 5tate laws relatin! to building construction, I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property far inspection ANDEKP~~WHIMMAYMANYWAYAa31~EAGADlmSAID(TIYMCON~~~OF'IHEGRANlINGOF~~. purposes. IA19oERFE~SAVEINDEMNDYANDKEEP€URMIPSSTHE(TIYOFuRlsBADK;AGADl~AU.~~JUDGkwT$~ WU: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of StruCNres over 3 stories in height. provisions of this Code shall expire by limitation and become null and void if the in 365 day from the date of such permit or if the building or work authorized by is commenced for a period of 180 days (Section 303(d) Uniform Building Code). DATE: I 004 $5 WHITE# File YELLOW. Applicant PINK: Finance CITY BUILDING OF CARLSBAD DEPARTMENT NOTICE 7~~~7~ 438-3550 2075 LAS PALMAS DRIVE FOR INSPECTION CALL 438-3101. RE-INSPECTION FEE DUE? 0 YES PHONE WILDING &SPECTOR CODE ENFORCEMENT OFFICER ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO. CA 92 123 (619) 5601468 The plans transmitted herewith have been corrected where necessary and substantially com?ly with the jurisdiction's building codes. The plans transmitted herewith will substantially comply n with the iurisdicfion's buildinq codes when minor deficien- - - - ' cies identified checked by building department staff. are resolved and 0 identified on the enclosed check list and should be corrected The plans transmitted herewith have significant deficiencies and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Cor?. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the 0 jurisdiction to return to the applicant contact person. 0 The applicant's copy of the check list has been sent to: \ !s Esgil staff did not advise the applicant person that plan check has been completed. 0 Esgil staff - did advise applicant that the pla been completed. Person contacted: Date contacted: Telephone # REMARKS: ?tS-SOh, tZaWw tsL~ nie &?t~??W,4 - pO/d OF TttE McC'ST 3 160 \ By: DbtIE&J7l? ESGIL CORPORATION Enclosures: lo-18- 95 ESGIL CORPORATION 9320 CHESAPEAKE DR.. SUITE 208 SAN DIEGO, C.4 92123 (619) 56W146-S !.4TE : 10-5 -9'5 JURISDICTION: CARLSBAD Lj?LP.K 0 necessary and substantially ccr;:?ly with the jurisdiction's The plans transzitted hersxith have been ,corrected xhere building coces. 0 with the jurisdiction's -Suil&i-g codes .&?'en 3.inor leficien- The plans transmitted herewith will substantially conply cies identified are rtsolvs3 an.3 checked by blilding department staff. The plans transmitted herewith have significant deficiencies and resubmitted for a complete recheck. The check list transnitted herewith is for your information. plans are submitted for rechec:k. The applicant's copy of the check list is enclosed for the 0 identified on the enclosed check list and should ba corrected a The plans are being held at 'ssgil Cor?. until corrected 0 jurisdiction to return to the applicant contact person. .m The applicant's copy of the check list has been sent to: GHRY R O&C 4 @ Esgil staff did not advise the applicant contact person that plan check has been completed. O been completed. Person contacted: Esgil staff - did advise applicant that the plan check has Date contacted: Telephone t 0 REMARKS: By: MG DDLIEUW Enclosures: OGA OCM E4 @., ESGIL CORPORATION 10- y-r.5 FmmoRD: PLUSBREAD Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy handicapped. The plan check is based on conservation, noise attenuation and access for the regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1991 UBC (eff. 8/14/92) 1991 UPC (eff. 8/14/92) 1990 hZC (eff. 7/1/91) 1091 UMC (eff. 8/14/92) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The circled items listed need clarification, modification or change. All items have to be with the cited codes and regulations. Per Sec. satisfied before the plans will be in conformance the plans does not permit the violation of any 303(c), 1991 Uniform Building Code, the approval of state, county or city law. To speed w the recheck Drocess. note on this list lor a CODV) where each correction item has beq addressed Le.. ~l~n sheet. svecification. etc. Be the revised Dlans. sure to enclose the marked m list when VMI submit , .. . - PWlS Show on the title sheet all structures, pools, Please make all corrections on the original tracings and submit two new sets of prints, to: o~ Esgil Corporation, 9320 Chesapeake Drive, included vnder this application. Any portion of the project shon on the site plan that is not included vith the building permit application filed should be clearly identified as "not included." Suite C209, San Diego, California 02123. I (619) 560-lL58. Please &.e all corrections on the origiral tracings and subait two new sets of prints, to: me jurisdiction's building deparment. Indicate on the Title Sheet of the plans, the name of the legal ohner and me of person resoonrible for the oreoaration of t. Section 30?(a)7. 'le olans. All sheets of plans mst be signed by the person responsible for their preparation. (California Business and Professions Code). Plans, specifications and calculations shall be signed by the California state licensed preparation, for plans deviating from engineer or architect responsible for their conventional wgod frame construction. Specify expirati rr date of license. (California Business and Professions Code). Specify on the Title Sheet of the plans the project including dwelling, garage, carport, gross floor area of each element of this patio, deck and balcony. Section 302(d). Provide a sbtement on the Title Sheet of the plans that this project shall comply with Title 24 and 1991 UBC, IMC and UPC and 1990 NEC. ~ ~~~ "." """ " Submit fully dimensioned plot plan dram to existing end proposed structures on the lot. scale shoving location, size, and use of all and all easements. Show location of all cut or Identify property lines and show lot dimensions fill slopes. Show finish floor elevations md shov elevations of adjacent finish grade. Section 302(d). Show drainage patterns with minimum slopes. Indicate distance from property lines to proposed construction. Section 302(d). $ Clearly show if the lover leyel is a basement or a story, based on the definitions in Sections 403 and 420. Plot the finish grade the distance to the floor above, for story (as defined) on t3e elerations and dimension detennination. )f % the corer sheet of the p!ans, specify a7y Items requiring special inspection, in a back. fcnrat similar to that shorn below or sticky In addition to the regular inspections, the following checked items will also requixe Special Inspection in accordance with Sec. 306 of the Eniforu Building Code. EOUlRED SPECIAL INSPECTIOSS 1E-I EO. IF F34ARKS SOILS COWLILVCE PRIOR TO FOUNDATION INSP. &C:ckzD STRUCTLIRAL CON= OVER 2500 PSI PRESTRESSED sm FIEU) WING HIGH SmGM BOLTS EXPANSION ANCHORS SPECIAL PVlSONRY SPRAYED ON FIRE PRWFING PILEs/cAIssoNs DESIGKfR-SPECIFIED OMER A. Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings. Table 5-A. 8/5/92 2 ' property line shall have 30 inch parapets h.hen q Exterior valls closer than 3 feet to a the floor area per floor exceeds 1,000 square feet. See Section 1710 for possible exception. f- more than 12 inches into the 3 foot setback Projections, including eaves, may not extend from the property line. Section 504(b). #. Eaves over required vindovs shall be not less than 30 inches from the side and rear property lines. Section 504(a). y/. Projections, including eaves, shall be one-hour fire-resistive construction, hea\y timber or of noncombustible material if they project into the 3' setback area from the property line. Section 1711. jd: Plastic skylights shall not be installed within that portion of a' roof located vithin a distance to property line where openings in exterior walls are prohibited or required to be protected. Section 5207 (a) 7. Shov locations of permently wired smoke detector with battery backup: a. each bedroom. b. Centrallv located in corridor or area giving access to sleeping rooms. c. on Each story. d. In the basement, if part of the dvelling e. When sleeping rooms are upstairs, at the unit. upper level in close proximity to the f. In rooms adjacent to hallvays serving stair. bedrooms, vhen such rooms have a ceiling height 24 inches or more above the NOTE: Detectors shall sound an alarm audible ceiling height in the hallway. in all sleeping areas of the unit. Section 12lOT- When the valuation of a room addition or repair exceeds $1,000, or vhen sleeping rooms are created, smoke detectors shall be provided at existirg bedrooms per item 19. above, .exceDt that smoke. detectors added at existlng construction need only be battery powered. Section 1210. fl. Sleeping rooms shall have a vindow or exterior door for emergency exit. Sill height shall not exceed a" above the floor. "he vindov must have an openable area of at least 5.7 square feet vith the minimum openable vidth 20" and the minimum openable height 24". Section 1204. d. Easements in dvelling units shall comly with the above (euen if not designated as sleeping rooms). Section 1204. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (b). Appears to be deficient in K~f~f"T\I /DEd. sfid Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and minimum is 1.5 sq. ft. Section 1205 (c). At least 112 of the comon wall must be open and have an opening not less than 25 sq. ft. nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room. Section 1205 (a). Jd Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet. the loneer side is at least 65% open, id~lhe porch huts a street, yard or couri. Section 1205 (a). 26. Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry vindovs are not provided. Section 1205 (c). rooms and similar rooms if required openable 4. Note that the discharge point for exhaust air will be at least 3 feet from any opening into the building. Section 1205(c). ,d Ductless fans mot be used in bathrooms if a tub or shower is present. Section 1205(c). ~wsmzRIIuKpIxIIRQ(wIs #. show that ceiling height for habitable rooms 71: Habitfble rooms, other than kitchens, shall is a minimum of 7'6". Section 1207 (a). contam at least 70 square feet of floor area. Show ceiling height for laundry rooms, At least one room shall have not less than 120 square feet of floor area. Section 1207 (b). pf hallways, corridors, and bathrooms is a minimum of 7'0". Section 1207 (a). . No habitable room, other than a kitchen, shall 7 be less than 7'0" in any dimension. Section A. Dhsion on the plans 30" clear vidth for water closet compartments and 24" clearance in 1207 (c). front of water closet. Section 511 (a). i CITY OF CARLSBAD * INSPECTION REQUEST PERMIT# CB931074 FOR 02/16/94 INSPECTOR AREA PY DESCRIPTION: 192 SF ADDITION TYPE: RAD CONSTR. TYPE VN JOB ADDRESS: 2392 APPIAN RD STE : LOT : APPLICANT: NEUSCHAFER, DAVID PHONE: 619 726-210 OWNER: PHONE : OCC GRP R3 PLANCK# CB931074 CONTRACTOR: PHONE : REMARKS: MH/GARY/749-3976 SPECIAL INSTRUCT: TOTAL TIME: CD LVL DESCRIPTION INSPECTOR /? A, ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical " " - " - ***** INSPECTION HISTORY ***** DATE 012794 011994 011994 011994 120993 120993 120993 120993 120693 111893 DESCRIPTION Interior Lath/Drywall Insulation Frame/Steel/Bolting/Welding Exterior Lath/Drywall Roof/Reroof Frame/Steel/Bolting/Welding Rough Electric Shear Panels/HD's Frame/Steel/Bolting/Welding Ftg/Foundation/Piers ACT INSP COMMENTS AP PD AP PY FOAM AROUND WINDOWS AP PY AP PY AP PY PA PY AP PY AP PY OK TO WRAP OK TO WRAP NR PY MET W/CONTRACTOR PA PY SEE LIST Show safety glazing in the following a. Where the nearest edge of glazing is locations, per Section 5L06(d): within a 24-inch arc of either side of a door in a closed position (unless there is an intervening wall between the door mnd higher above the walking surface). the glazing or if the glazing is 5"O" cr b. Glazing greater than 9 square feet vith the bottom edge less than 18" above the floor and the top edge greater than 36" above the floor (unless the glazing is more than 36" horizontally away from h.alking surfaces or if a complying c. Glazing in shower and tub enclosures protective bar is installed). or shower floor) (including windows within 5 feet of tub / Walls and floors separating units in a duplex shall be of one-hour fire-resistive construction. Provide details of the assemblies. Section 1202(b). $/ A mezza.ine is an intermediate floor and my not have a floor area exceeding 33 113 percent of the total floor area in the room below. Ihe mezzanine floor mst have a clear height of 7 feet, above and below, and must have the loxg side open to the room below except for posts and protective walls or railings not exceeding wi" in height. Section 1717. b. The loft you show does not comply as a mezmine floor and is, by Uniform Building Code definition, a story. Section 1717. rLlDii& tL#s PDOF tWJ1 6 . Dwellings used for daycare for 1 to 12 children Chapter 12 of Title 24. m. SLAImAYS. AND RAllMGs $. Floors above the second story shall have not roofs may have one exit if such occupied areas less than 2 exits. . Exceptions: 1. Occupied are less than 500 square feet and located no higher than immediately above the second story. 2. when the third floor within a nit does not provided. Section 3303(a). exceed 500 sq. ft., only one. exit need be . Required exit doorways shall be .not less than 36" in width and not less than 6'8" in height. y. porches, balconies, and open sides of stair Provide 36" high protective railing for landings. Openings between railings shall be by the riser, tread and bottom elements of a less than 4". The triangular openings formed guardrail at a stair shall be less than 6". Section 1712. . Show how guardrail connection details are f adequate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. )d Provide staimay and landing details. Section 3306 (b), (c) and (0). a. Maximum rise is 7" and minim m is ~~ ~~~ ~ 11". %en the stairs serves less than 10 -E pdyy rise may be 8" maximum and run 9" occupants, or serves an unoccupied roof, re M P minimum. b. Minimum headroom is 6"s". c. Minimum width is 36". &+ All handrails per Section 3306 (i), shall satisfy the following: a. Provide handrail for staimays with 4 or more risers. b. Handrails and handrail extensions shall be 34" to 38" above the nosing of treads. c. The handgrip portion of haTdrail shall be not less than 1 1/2", nor more than 2" in cross-sectional dimension. d. Except for stairs serving only one tenant, handrails shall be extended 12" beyond the top and bottom of the stair. ? Every stairway landing shall have a dimension, measured in the direction of travel, at least equal to the stairday width. If a door occurs at the landing, such dimension need not exceed 36 inches. Section 3306 (g), 3304 (j). An interior door may open at a landing that is not more than 8" lower than the floor level, provided the door does not swing over the landing. Section 3304(i). ,id Provide details of winding stairway complying with Section 3306 (d): a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from where the treads are narrowest. b. Maximum rise is 8 inches. C. Minimum width is 36 inches. 7 walls, floor and roof diaphragms. Indicate . Specify nail size and spacing for all shear rewired blockine. Maintain maxim diaohraw d&ension ratio;. [Tables 25 I, J, 'K Gd Section 1714 (d)]. I' for this project. Specify truss identification . Provide tmss details and tmss calculations l&. Show 112" mininm cleuance betveen top plate of interior Dartitions and bottom chord of numbers on the plans. trusses. (io ensure loading will be +s designed). 14. Provide roof framing plan and floor frming d. Pror-ide framing sections through plan. Sectim 302 (d). Section 302 (d). wide. Section 2517 (9) 5. Specify all header sizes for opening over 1' horizontal franing members &?d post footings. Provide calculations for main vertical and Section 302 (b). 0 127. Show location of attic access with a minimum headroom height in the attic is less than 30". size of 22"x30", unless the maximum vertical Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 3205(a). 1,d Show location of attic access with minim- slze ??" x 30". Section 3205. Detail truss layout for 30" x 30" attic access, if required for equipment in rbe attic, and detail 30" x 30" clearance through truss webs. $0. Specify plyvood andlor particle board thzckness, grade and panel span rating. Iable 25-S. 1 3f Show plywood sheathing over exposed &wes, or other weather exposed ares, is "bonded with wall covering shall be the exterior tpe. exterior glue." Plywood used for exterior Section 2516 (i), 2516(g)3. When roof pitch is less thw 3:12, desig ridge as a beam. Section 2517 (h). 4. Ridges, hips, and valleys shall be at least . Provide calculations for lateral loads, shear panels, shear transfer and related. Section I one- size -1irger than- supported rafters. Section 2517 (h) 3. , 302 (bj. wall values for drywall in Table 47-1 must be In Seismic Zones 3 and 1, the allowable shear reduced 50 percent hen considering earthquake loads. This does not awlv to wind loads. 1 1. In open beam construction, provide strap ties 1 across the beams at the ridge support. Section 2501 (b). If foundation cripple wall studs are less than 11" hieh. framine shall be solid Footnote 1. ._ ~ blockine. or rhiathed wi& Dlwood. Section . Show on the plans all structural requirements developed in the structural calculations. Section 302 (d). (See cments below or at end.) . Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and hkich support permanent structures shall be projecting above floors unless approved wood supported by concrete piers or metal pedestals of natural resistance to decay or treated wood is used. Section 2516 le\ Ir. 2517 (gS.4. .. 186. Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (9) &. . Note on the plans that "all weather-exposed surfaces shall have a weather-resistive barrier to protect the interior wall covering and that exterior oDenines shall be flashed in such a mer as io m& them weatherproof". Section 1708. ~ ~~~~~~. "" .-, - -CAI, (vwIPcwac "IC& WDQ . Individual concrete or masonry piers shall project at least 8 inches above exposed ground All heating, ventilating, and cooling systems and unless the columns or posts which they support appliances shall comply with the Uniform Mechanical are of approved wood of natural resistance to Code. decay or treated wood is used. Section 2516 (c) 1. 5/22/92 8 0 138. Show the size, location and type of all heating and cooling appliances or systems. l#. Every dwelling unit shall be provided with heating facilities capable of naintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 1212. alcove nust be 12 inches wider than L5e Note on :he plans that the FAU closet or furnace or furnaces being installed. LMC Section 7W. 1&/ Show minimum 30" deep unobstmcted working space ln front of furnace. Section 505, WC. Furnace shall not be installed in any bedroom, barhroom or in a closet or confined space with access onlv throueh such room unless soecified as direct vent appliance, enclosed furnace or electric heating appliance. - ~" Section 701, VnC. 1&. Show source of combustion air to furnace, per Cnapter 6, UHC. to be minimum 30 inches by 30 inches. 'ine Show access to t!!e attic containing equiplent opening nay be 22 inches by 30 inches if t..e equipment can be removed through such open-kg. l~. Section 708 VnC. Rote that passageway to the attic furnace shall be unobstructed and have continuous not more than 20 feet in lengt!! through the solid flooring not less thm 24 inches wide, attic. Section 708 UHC. f fixture controlled by a switch for furnace 6. Show permMent electrical Outlet and lighting 708 h 709 W. located in attic or underfloor space. Section fvrnace under the floor, or Section 710 for . Show details to comply with Section 709 for roof or outside furnace. 14. Show I.C.B.O. approval number for prefab per I.C.B.O. ipproval or:Iable 37-B. fireplace. .: 'Show height of chimney above roof Note on the plans that approved spark arrestors rhall ba installed on all chimneys. Section 3703(h) Hots on plan: Gar vents md non-combustible piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (c). l#Provide dryer vent to outside. UHC, Section 1903. All wiring shall comply with the National Electrical Code. n Show on the plan the amperage of the electrical service, the locarion of the senice pmel and the location of any sub- panels. If service is over 200 qs, subnit single line diagram, panel schedule and load calculations. Show on the plan that receptacle ou:lets comply vi-& 1990 hiC Art. 210-52(a), which rea& as follows: In every kitchen, dining room, parlor, library, den, swoom, bedroom, recreation room, or similar rooms or area of dwelling units, receptacle outlets shall be installed so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from M outlet in tht space, widL5 a.d tAe wall space occqied by fixed includhg any wall space 2 feet or more in panels in exterior walls, but excluding sliding panels in exterior walls. The wall spacf 'fforded by fixed room dividers, such as free-.tanding bar-type counters, sh.11 be included in the 6-foot measurwent. controlled lighting outlet shall be installed (c) Other Locations. At least one well switch- at or near heating, air-conditioning, and refrigeration equipment in attics or underfloor the point of entry to the attic or underfloor spaces. The light switch shall be located at on the alan that eround-fault circuit- -L ~ : Interrupter piocection c&plies with 1990 hfC L-t. 210-8, which reads as follows: (a) Dwelling Knits. (1) ~ll 125-rclt, single-phase, 15- md 20- ampere receptacles installed in bathroom protection for personnel. shall hare gxund-fault circuit-interrupter (2) All 125-rolt, single-phase, 15- or 20- ampere receptacles installed in garages shall have ground-fault circuit-interrupter protection for personnel. Exception So. 1 to (a)(2): Receptacles which are not readily accessible. Exception 50. 2 to (a)(2): Receptacles for appliances occupying dedicated space which &-e cord- and plug-connected in accordance with Section 400-7(a)(6), (a)(7), or (a)(8). Receptacles installed under Exceptions to meeting the requirements of Section 210-52ig). Section 210-8(a)(2) shall not be conside:ea! as ampere receptacles installed outdoors where (3) All 125-volt, single-phase, 15- and 20- there is direct grade level access to ;he dwelling unit and to the receptacles shall have ground-fault circuit-interrupter protection for personnel. protection. (FPN): See Section 215-9 for feeder For the purposes of this section, "direct grade level access'' is defined as bein located not more than 6 feet, 6 inches (1.98mY above grade level and being readily accessible. ampere receptacles installed in crawl spaces at (4) All 125-volt, single-phuse. 15- and 20- or -below grade level and in unfinished basements shall have ground-fault circuit- interrupter protection for personnel. Exception No. 1: A single receptacle supplied by a dedicated branch circuit which is located plug-connected appliance, such as a and identified for specific use by a cord- and refrigerator or freezer. Exception No. 2: The laundry circuit as required by Sections 210-52(f) and 22O-k(c). Exception KO. 3: A single receptacle supplying a pernwently installed sump pump. ampere receptacles installed within 6 feet of (5) All 125-volt, single-phase, 15- and 20- a kitchen sink to seli'e crmter top surfaces protection for personnel. shall have ground-fauit circuit-interrupter (TPN): ihe intent of =!is subsection is to permit the exemption of receptacles .xhich are located specifically for appliances such as refrigerators and freezers from gromd-fault circuit-interrupter protection for personnel. GFCl Protection for Personnel Receptacles in the Vicinity of Kilchen Sinks 2704WW L6'4 j-S-[ 0 prmenr: Iownwnc PLMBITI; awE\ 158. Show water heater size, type and location on &. Note on the plans that "combustion air for fuel burning water heaters vi11 be provided in accordance with the Uniform Plumbing Code". Fuel combustion water heater shall not be bedroom, or in a closet opening into bath or bedroom. LQC, Section 1309. heater from vehicle damage. An 18" platform Provide adequate barrier to protect water for the water heater does not satisfy this requirmt. UPC, Section 1310. plans. WC, Section 1301. 8/6/92 11 'P 1 2.'Show T and P valve on water heater and show route of discharge line to exterior. 0 172 All energy items shobn on the plans mst be in agreement with the information shobn on the UF'C, Section 1007 (e). properly completed Form CF-1R. n Show that water heater is adequately braced to resist seismic forces. UPC, Section 1310. Show shower stall can accomodate a 30" circle and has a minimum floor area of 1,024 sq. in. PC 909 (d). Prcvide clothes washer hook-up for each wit. -.+ ,>.le 24, Part 3. Kew water closets and associated flushometer valves, if a?y, shall use no more ti=? 1.6 gallons per flush and shall meet perfomace s+e?dards established by the hmerica? Sational Standards Institute Standard h112.19.2, End vinals and associated floshometer valves, if my, stall use no more than one gallon per flush and shall neet perfomce standards established by the hmerican Sational Standards Institute Standard hl12.19.2. H h S Code, Section 17921.3(b). WOIS MSIJUnON (-1 it. and floorlceiling assemblies to achiere a Show details of duplex conmon (party) walls Somd Transmission Class (STC) rating in sal!s of 50 decibels and an Impact Insulation Class iitle 24. (IIC) rating on floorlceiling of 50 decibels. d 1 8. Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound trensmission rating. Title 24. ' achieve STC of 50 between garage and living 9. irovide insulation in valls and ceiling to area if garage use is not controlled by resident. Title 24. NOE: Plms submitted after January 1, 1993 must comply Vith the new energy standards. 170. Provide plans, calculations and worksheets to 0 0 show complimce vith current energy s*a?dards. 171. The regulations require a properly cqleted and properly signed Form CF-1R to be either iorprinted on the plans, taped to the plms or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirenents of the approved energy design. U 173. Specify on the buildine plans all of the mandatory energy consen*ation requirements as Measures Olecklist." listed on the enclosure titled, "wandatom 0 0 0 7. 174 Show the &e, model and efficiency of t!.e space heating (or cooling) syster. For rooin additions, show conplirnce with the A. Provide fluorescent general lighting (LO energy standards. See attached. lumens per vatt) in kitchen(s) and bath-ooes. 177 Provide a note on the plans stating "hll new sith a certifying label attached, show t\e U glazing (fenestrations) will be instal:ed value." UTasBAD S.P.D. h WPLZX SUP= li8 Energy consenation design should be fcr Zone 9. For gas piping under slabs t\at sene kitchen islcqd cooktops, see the attached Policy 91-i6 ior special sleeve and cle&T-out requireJe;.rs. Sew residential units udst be pre-plmbed 50- + future solar water heating. Note "two roof jacks must be installed" where the uater heater is in the one story garage and directly below the most south facing roof (City Ordbce So. 8093). Xote "two 3/L8' copper pipes must be installed to the mcst convenient future solar panel story garage and is not directly belov the location when the water heater is not in a one most south facing roof. (City OrdiMnce So. for presext cr futL-e solar water heating mst bc insulated when in areas <?at are not heated or cooled by mechanical mans (city policy). Incorporate the waterproofing details, on the attached Policy 80-8, rfiere interior living space occurs belcw grade a: the lsasorry wall(s). 0 184 Show on the Iitle Sheet on the plans, the Developmental Services Sheet 112383. information required by the attached "s" All . new residential buildings, including addltions, require a soils report. Please addition is limited to one story and 1000 sq. suhnit two copies. Exception: If a room ft. in area, then a soils report is not required. Esgil Corporation vi11 advise the plans. City to place their soils notice staq on the 1$6*11 structures require a Class B roof covering, except room additions. If a room addition carers all of the existing building (2nd stcry addition), then the abore exception doesn't 4 P apply. 7. City Ordinance 9792 reqxizes tb.0 parking spaceslunit with clw ared of 20'x2O1 i.e. no v-ashing machi.nes,,etc. Show conpliance. 1 8. Cxerflow roof drains sha1.l terminate in 81 aru xnere they vi11 be readily visible and vi11 nct cavse damege to the building. If the rocf drain terminates through a vall, the overflov kaia shall terminate 12" minimum above the roof drain. Policy 84-35. Please see additional corrections, or rersrks, lo speed up the recheck process, note on this on the folloving page. Pss been addressed, i.e., plan sheet, note or list (or a copy) where each correc:ion item detril number, calculation page, etc. 0 191. Please indicate here if any changes have been =de to the plans that are not a result of corrections from this list. If there are and where they are lourted in the plans. other changes. please briefly describe them Have changes been made to the plans not resulting from this correction list? Plwe check. Ses X0 Ihe City of Carlrbad has contracted with Ergil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone nmber 619/560-1168, to perform the 'plan check for your project. If you have my questions regarding these plan check items, pleass contact Ihank you. Enclosures: 1. 6125193 13 ENERGY REQUIRMEWTS FOR RESIDENTIAL ROOM ADDITIONS - CLIMATE ZONE 7 COYPOSENT Floor Area cf Room Addition 1@0-499 ft' GLAZING (fCX'EST74TION) >?e Dual, with non-metal frame: with ncn-metal frame: 2.31, % sf added flocr area 553 sg. ft. iC% + Removed' -..,,>-. 2 .----, I h G n/a ." cc: -:z-,,,, ...-S*-Ad I.'4.SS n/a -" 4 = _I . EFAC3 :SATING !cote G~ .:x electric allcued) " ;I Cas, efficiency- LT :-:eat ~ump: I cb.rC35 :>lit System, efficiency= 5 .:.?+:I- Sizzle Package System, %if.= I. -7.-r:- -.. ~-. " ^.."_& S1;.4CS COOLING If Split System, eff.- If Single Package. eff.= 9.1SEER' sot e' io. 3~~5~5 XATEX XSATING Note Xcte' .. x-30 S-33 3-13 3- 13 R-i9 3-15 - 1. TO satisfy the required U-value of .75, ncn-metal frames are required. Aluminllm franes may be used at fixed glezing only. 2. 20% of added floor area plcs the area cf any glazing renoved because of the addition. 3. A coefficient of 0.66 will be essumed to be provided when dual glezing is used. 4. If the addition will be on top of existing construction, and: (a)If the addition hes conditioned area below all portions, then no thermel mass is required. mostly of raised-floor construction (tfter the addition), then thermal mass is required (b)If the addition will be over non-conditioned area (partially or wholly) in a building in the addition (equal to 5% of the area of the addition that is over non-conditioned space). This may be provided by showing a 2" concrete slab at hearths, countericps, etc. (c)If the addition will be over non-conditioned area in a building mostly of slab-on- grade construction (after the addition), then no thermal mass is required. If the addition will be at the ground floor, and: addition), then thermal mass is required in the addicicn (eqial to 5% of the added (a)If the addition will be in a building mostly of raised-floor CCnSKrUCtiOn (after Khe conditioned footprint area). This may be provided by shcwing a 2' concrete slab at hearths, countertops, etc. the addition), then thermal mass is required in the addition (equal to 2Ot of the added (b)If the addition will be in a building mostly of slab-on-grade construction (after conditioned slab-on-grade floor area). This may be provided by covering a portion of the slab-on-grade with tile, wood, ecc. 5. If the existing system will be utilized (if no additional systems are needed to provide UBC heating requirements), there are no special requirents, other than mandatory insulation for any extended ducts, etc. 5. If the total number of water heaters increases in the residence, then calculaiions must be submitted to show that the entire existing-plus-addition system meets the water heating energy budget. 8-93 ER-RAl LIIlGdlt: UI WlllplldIlW; neslaenual (Page 1 of 2) CF-1 R Project Tlllo Da Io I 1 . ProJecl Addreu I Building Permil t I kurnmlallon Aulhor Telephone Compllsncd Uslhod (Padape. Poinl Syrlern or Computer) Cllm.le Zone Enlorcamenl AQency Use Only Plan Check/ Dale GENERALINFORMATION Total Conditioned FloorArea: e* Building Type: - Single Family - Addlion Front Orientalion: _. North 1 EaslI South I West I All Orienlalions Number of Dwelling Units: Floor Construction Type: Slab I Raised Fioor (circle one or 53th) (G%& one or more) - Muili-Family - Existing-Plus-Addition (Input orientadon in degrees ad cirde one.) BUILDING SHELL INSULATION Component TVDe Wall .............. Wall .............. Roof ............. Roof ............. Floor ............. Floor ............. Slab Edge .._. Insulation Assembly LocalionCornments R-value U-value (anic. to garape. IyDical. e:c.) Construction FENESTRATION Shading Devices Fenestration Area Fenestration lnlerior Orientation (SO Exterior Overhang .. Framing Type' . U-value (roller blind. ecc) (shadescreen. elc.) (ysdno) (rnelaho&tviri$) Front ..... ( ) Front ..... ( ) Left ....... ( ) Left: .. :... ( ) Rear ..... '( ) Rear ..... [ 1 Right ..... ( j Skylight Right..,.. ( ) Skylight ....... ....... THERMAL MASS TypelCovering Area Jsl*/exposed, tile. etc.) Thlckness (Sf) (inches) LocalioWDescription (kitchen. bath. elc.) _. . ~.. ......... ......... ...... ~ ... ........ _,.. ................ wxmcare ot L'ornpliance: Residential (Page 2 of 2) C F-1 R .. Project TItIe Dsle HVAC SYSTEMS NDle: Input hydronic DT mmbined hydronic data under Waler Healing Syr:emt. except Design Heating Load. Heating Equipment Minimum Type and Type (lurnace. heal Etficiency Location Duct or purnD. elc.) (AFUVHSPF) (ducislazic. elc.) R-Value Type Dislribu!ion Piping Thermostat Cooling Equipment Type (air wndnioner. Efficiency Minimum Duct Loca!ion Duct Thermostat Configuration heat purnD. evaa ooiinp) (SEER) (saic. et.) R-value Tvpe (SDlit or packaqe) - WATER HEATING SYSTEMS Rated' Tank Energy' Exlernal Factor or Water Heater Dislribulion Tyoe TYD~ Number Input (kW Capacity fiecovery Standby' Insulation in System or B!u/hr) (oallons) Efficiency Loss (70) R-value Tank 1. For amall gsr storage (ramdinputs 75.003 Btuhr). elcclrls resistance and heal pump water hMlar.lisl Energy Facur: For Iarfie gar storage waler hMlm (raled input 2 75.0W 3rhr). list Raled Input Recavey Eficency and Standby Loss. For tnrunlanwus gar wrler hulen. lis1 Rated Inp,t and Rwey Etficiency. SPECIAL FEATURESIREMARKS (Add extra sheets if necessary) COMPLIANCE STATEMENT This certirkale 01 comgance lists lhe Mding leatures and performance spcilications needed lo amply with Tflk 24, Parts 1 and 6, of . Vle CaGlomia code of Regu!afins, and Ihe administraSve regulalions IO implement them. This cellifcale has been signed by the onenhtions, any shadii IesWre that is varied is indiiled in the Special FeatweYRernarks section. infMdual with overan desipn respnslbility; when this cerlilic.se of mpliince is submined lor a single building plan to be buill m multiple Deslgner or Owner (per Buslnerr L Prolnrlonr Code) Documentation Author Name: Name: mWFii: Address: Telephone: Lic. 1: li*ffm: Address: Telephone: Enforcement Agency - Name: Mandatory Measures Checklist: Residential MF-1 R NOTE: Lowrise residenlial buildings subject IO :he Standards must contain these measures regardless 01 the compliance approach used. I!ems mahed with an aslerisk (*) may be superseded by more stringent complianca requiremen!s listed on the Cerlificate of Compliance. When this checklist is incoporated inlo !he permit documents. the features noted shall be considered by all parries as binding minimum component pedormance 5peCifica:ions for the mandatoly measures whether lhey are shown elsewhere in !he documenls or on !his checklist only. DiSCiilPTlON 1 DESIGNER I ENmRcEtmT 1 Buildlng Envelope Measures I I I §lso(a): Minimum 17-19 ceiling insulation. . glSO(b): Lwse M insulation manufactm's I;beled R.Vdue. . §lsO(c): Minimum R-13 kall insulajon in hmed kalls (dces not qqly 10 exleriw mass walls). i I - §lY)(d): Minimum R.13 fa% fimr ir.su!adon in hmed bmrs; mininum R-6 in mncele raked box. ~ $1 WI): Slab edge insulatim . wafer ahsaption "le no g:ealer ta 0.3%:. waler vap basmission rale no 5rea:er lhan 2.0 permrincil. $1 18: Insulath s~.fied or ins'slled mm Calilonia EnerGy Conmission quality s'aizds. Indicale type and lorm. si 16-1 7: Fenessalion Prcducs. Ex!erior Dmrs ad InfiI:rtion'ExKlbztion Controis a. D~PK and vbisws between wndijoned and unmn5ibned s~ces desiyed to limit ai le2bge. 5. Manu:adu:ed fenesbadon prcduc3 hwe !&e! wim cerUfied U.vz;ue. and infibaeon cerdfidbn. c. Exlerior doors and windom weahersoippj; all joink "I ?nebations caulked and s~ded. $1 5O(g): Vapc briers mandatory in Climate Zones 14 ad 16 only. $l53(9: Spechl inflhation harrier ituslied 10 mp!y with 51.51 mees Commissia? qudty slandards. glso(e): Insla", 01 Fuplaces, brahe Gas kpph;xes and Gs Lgs 1. Masenry and '&q.bVat fuepbces have: a ClcseaMe metJ of gkw dm . b. outride air intake with lamp and onhd c. flue damp and onbd 2 No mntinws burning ga pilots ailowed. Space Conditioning, Water Heating and Plumbing System Measures $110 -13: WAC equipment water healers. showerheads and faucets cerijfied by the Commissbn. $1 530: Semadc hrmos'a on ail qpiicable heating systems. $1 XI@: Pip and Tank lnsubtim 1. Indiied hot de! tankr (e.?., unfired stwage Lank M badrup solar hot watw lank) have insdadoa 2 Fust 5 leet d pipes cbsesl to watw healer tank m-redrwbting systems. hsulatej (a-4 of greater). Wet (R-12 M greater) M mtined intehor/exleriw insu'atim [R-16 w greater). 3. A0 buried 01 expcsad piping insulated in redrwMng YX~DI-S 01 hot mter syslem. 4. CoSng system piping be& 59F insulated. 5. Piping insuhled behen heating mrce and indiued hot water tank 1. Duds CaObiJcled. installed and sealed to mply with UMC Mons 1002 and 1w4: duh insu!ated 2. Exhaust fsn systems have backdran M automatk dampers 3. Gravity venblatkg systems serving wndi6oned spce have either aulomatic or readily accessible. . g15o(m): hrcband Fw to a minimwn inshlled value 01 R-4.2 of duck enclosed endrely within dXioned spce. manually operated dampers.. $1 14: Pcd and Spa Heating Syslems and Equipment 1. System is Deniced with 78% thermal efiijency, on-off swilh. weatherprwl operating 'nstruc$ms, 2 System is instakd with: 110 elec3ic resis'ance heating and no pilot light a At least 36' pip behveen filter and healer lof bbre sdar heating. 3. Pool splem has &r&MdinleQ and a drculatbn pump bine switch. b. Cavn lcf outdmr pmls OT ouldmr spa 51 15: Gas-hed ental lurnace. pml healer, spa healer M househdd cxling appliance have 110 mhnuously burii plot iighl (Gcepn'on: Nmelechicd cooking qp6ance with pilot c 150 Btulhr.) Llghtlng Measures $1 Wk): 40 IumenWH M grealec la general bhdng in kitchens and lwms wih watw dcsets; ad fmed Ceri 6lturK IC @WJbtbn We!) WPfWed. Revlred January 1992 t I r r i r - i I I . . ... .. .. :.. ~..ji.i ..... . .. "._ ...,.. i~ ,..... . .. .. . . DEVELOPMENTAL SERVICES BUlLDlNG DEPARTMENT 6itp of KarIsbab THE INFORPATION LISTED GELOW MUST 3E SiiO'n'N OH THE TITLE SHEET OF THE PLANS FC2 YO!JR SINGLE iAHILY D'n'ECLING Site Address Legal Description Assessor's Parcel NLe.ber quantity of Grading in cubic yards Contcct Person - Name and daytime Fhone Nuaber Circle any Planning tomission or City Council Action oh this Property: Variance, Coditional Use Penit, Tract or Parcel Map. Zone Change, Planned Development, Redevelopment Permit, Specific Plan, Site Development Plan PUN CHECK NUMBER cd 112383 Date1 I D1S-f 9 '5 Jurisdiction cA- 0 Sldg. Dept. 0 Esgil I I I I -+ I I I I .I I I I 'I I I. I I '@ Air Conditionine I I I Commerciel . Residential P .I Res. or Corn. Fire Sorinklers @ I .. Totrl Value i Building Permit Fee 5- Plan Check Fee S J r22,gr . 5 189. 03 COHHENlS: SHEET [ OF / 12/87 “ DATE: <%&L3 BUILDING PLANCHECK CHECKLIST PIANCHECK NO. 73 -10 7fL BUILDING ADDRESS: d c? 9 d .&//wd A&dJ PROJECT DESCRIPTION: kkf. /e294 hbd /;la ???- Ad ASSESSOR’S PARCEL NUMBER: 3 70 ‘63’” EST. VALUE 17 epfl ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, submittal; therefore any changes to these items information and/or specifications provided in your after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. DENIAL Please see the attached report of deficiencies marked with= Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected Dlans and/or sDecifications to this office for review. AlTACHMENTS CONTACT PERSON 0 Dedication Application 0 Dedication Checklist 0 Improvement Application 0 Improvement Checklist NAME: 0 Future Improvement Agreement ADDRESS: P\dou\ckLl~bpooo1 .hm REV 6/5/92 2075 Las Palrnas Dr. Carlsbad, CA 92009-1576 - (61 9) 438-1161 - FAX (619) 438-0894 @ BUILDING PLANCHECK CHECKLIST SITE PIAN / site plan drawn to scale. Show: Property Lines Easements Easements 0 Right-of-way Width & Adjacent Streets do 0 3. Drainage Patterns C. Existing Topography Existing & Proposed Slopes Show on a section drawing or include a note stating that there is a minimum of 6" difference between the finished floor and the finished grade elevation adjacent to the structure. Include note: "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)." On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.). Include on title sheet Site address Assessor's Parcel Number Legal Description For commercialhndustrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION P\docs\chldmbp0001 .hm Page 1 of 4 REV 6/5/92 BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE k$J3dJ &dJ 6. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by: Date: qAo DEDICATION REQUIREMENTS 7. Dedication for all street Rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ -pursuant to Code Section 18.40.030. Dedication required as follows: DO 0 Attached please find an application form and submittal checklist for the dedication process. Provide the Completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by Date: IMPROVEMENT REQUIREMENTS 8a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. Public improvements required as follows: ____~~~ ~ ~ Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans signed by: Date: Page 2 of 4 REV 6/5/oz . ! BUILDING PLANCHECK CHECKLIST 1stJ 2ndJ 3rdJ 0 0 0 8b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ necessary Future Improvement Agreement. This agreement must be signed, notarized so we may prepare the and approved by the City prior to issuance of a Building Permit. Future public improvements required as follows: 0 0 0 8c. Enclosed please find your Future Improvement Agreement. Please return signed and d notarized Agreement to the Engineering Department. Future Improvement Agreement completed by: Date: 0 0 8d. No Public Improvements required. SPECIAL NOTE: Damaaed or defective improvements found adiacent to buildina site must be repaired to the satisfaction of the Citv Inspector prior to occupancv. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 0 0 0 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 0 0 0 9b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Gradina Permit must be issued and rouah aradina approval obtained prior to issuance of a Buildina Permit. Grading Inspector sign off by: Date: 0 9c. No Grading Permit required. BUILDING PLANCHECK CHECKLIST P\doca\chWsi\bpoool.trm Page 3 of 4 REV 6lSlOz MISCELLANEOUS PERMITS 1sW 2ndJ 3rdJ 0 0 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or private work adjacent to the public Right-of-way. Types of work include, but are not limited to: street improvements, trees, driveways. A separate Right-of-way permit issued by the Engineering Department is required for the following: Please complete attached Right-of-way application form and return to the Engineering Department together with the requirements on the attached Right-of-way checklist, at the time of resubmittal. .q /o.o 0 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee 0 0 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by: Date: is noted in the fees section on the following page. Page 4 of 4 REV 615lS2 PLANNINGCHE- 3 Plan Check No. 93- /07V Address 2T 92 A ??/Ad b>. Planner VAN LYNCH Phone 438-1161 ext. 4325 (Name) Q APN: /67- 370-0: d Type of Project and Use mwPJ YYY -*e i OI Zone ,n"/ Facilities Management Zone o'bb LeaZd Item Complete - - 555 oao Item Incomplete - Needs your action 1, 2,3 Number in circle indicates plancheck number where deficiency was identified dm mi-" Revim w: yEs - No& mE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval APPROVAL,/RESO. NO. DATE: PROJECT NO. OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions d rrppowl &a California" .. PamitReqrtiredYES-N~- DATE OF APPROVAL: San Diego Coast Distdct, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval NO K See attached submittal requirements for landscape plans Site Plan: 1. 2. 3. 4. provide a fully dimensioned site plan drawn to scale. Show: NO& arrow, propew lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. Provide legal description of property. Provide assessois parcel number. 1. Setbacks: Front: Required u3' ShOwn-flr- kt. Side: Required Q'i" Shown Street Side: Required - Shown L Rear: RC@Rd - / @'f"Shown 23' 2. Lot coverage: 3. Height: ~ Required &J' Shown /hr 4. Parking: Spaces Required -how w-7- Guest Spaces Required - Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER 1/: b'L DATE /oGqy \ - ... .. I i Certificate of Compliance: Residential (Page 1 of 2) CF-1 R 8 " October 14, 1993 6.m hoial Addwu 2392 APPIAN ROAD, CARLSBAD, CA. DENco ENTERPRISES 726-0210 baummtwllon Aulhor nM Chock/ DIU , twlwphonw 7 Cllmt. Zon Enlorermnl Agency Uu Chiy QENERAL INFORMATION Tolal CondHbned Floor Area: 192 . 0 112 Number of Dwelling unns: Floor Conmnrctlon Type: &hi& Floor (clrdo one w both) BUILDING SHELL INSULATION CQmpOnent Tvps Wall .............. Wall .............. Roof ............. Roof ............. Floor ............. Floor ............. Slab Edge .... @IlStNCiiifl Assembly U-value LocabrVCornmems (anic, to garago, typkal, de.) 0.088 NEW EXTERIOR WALLS AduL" - FENESTRATION Shading Devices , Oriematbn Fenesffatbn Area Fenestratbn Interior Exterior Overhano FnmlngTypa U-value (rollor blind, dc) (rhadewwn, elc.) (who) (ma- Fro rt.... ( ) From ..... ( Len ....... (w) Len ....... (w) Rear ..... ( N ) Rear ..... ( ) Rb ht..... ( E) skylbtll Rim ( ) skvllgm ....... ..... ....... WERMAL MASS Vi n\rl 192. QO 4" NEW PLAY ROOM - . . . .. Cefllflcate of Compliance: Residential (Page 2 of 2) CF-1 R PLAYROOM ADDITION TIM October 14, 1993 owl. HVACSYSTEMS USE EXISTING SYSTEM ? NOD: Input hydronic (I cornbind hyhnic data undor Watw Heating Syrmrnr. exmpl Dnii Honing bd. Healing Equipment Minimum ~ype and Distribution Duct or TypO (furnace. heal pump. elc.) Eniiiency Location Piping R-Value Typf~ Thermosfat (AFUVHSPF) (ducWatic. etc.) Cwllng Equipment Minimum Dud Type (ah amdrier, Elficlency Localbn Ducl Themstd configuranon host pump, tvap. cooling) (SEER) (attic. rlc.) R-value Type (splll or rmkageL - WAERHEAnNGSYSfEMS USE EXISTING SYSTEM Water Healer Dislribulbn Number lnput(kW Capacky Recovery Slandby' lnsulatbn Energy' Rated' Tank Faclor or Taw EXiCnnal Type Type In Svstem or Elulhrl laallons) EHlciency Loss (%I R-Vabe - "I__" 1. fir #mall mu wlong. (mud iwul s 75,OoO Bruhr). *Irlrk nalrlmna and hem1 pump WWIU hulrr. lis1 Energy FUM; For brpou alomga welw hum (nM input 2 75.000 Bfuhr). list RNeO Input R.cony EMtimcy and Stan* Loss. For Ineununooua gam walw hrlr. lis1 bmd lnpul and Rcavwy EMwnq. SPECIAL FEAWRESlREMARKS (Add extra sheets If necessary) COMPLIANCE STATEMENT TN, CSrlMcals 01 mmpRance lists Ihs ajlaq lealms and performam spedficalions needed lo comply dth rilb 24, Pam 1 and 6, of Ihe CaB(wnia Code 01 Regubluns. and Ihe adminislralve regulallons to implement Ihem. This cerliliile has been signed by the WviW with overall desiw responsibility. When this cerlificale 01 awnplum is submitted lor a single tuilding plan 10 be kll h mdJs CliOnUtion8, any duding lealure lhal Is waried is Micaled in the Special Fealure~FIemafks Won. Ckslgner or Owner (p~ ou4-u L Prohalona ma) Documentrtlon Author Nm: Dave Neuschafer llWh~ DENco Enterprises *dbnr: 529 Hutchison Street Nam: Dave Neuschafer nwirm: DENco Enterprises .