HomeMy WebLinkAbout2402 LA MACERENA AVE; ; CB141261; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-07-2014 Residential Permit Permit No: CB141261
Building Inspection Request Line (760) 602-2725
Job Address: 2402 LA MAC ERENA AV CBAD
Permit Type: RESDNTL Sub Type: RAID Status: ISSUED
Parcel No: 2550702100 Lot #: 0 Applied: 06/06/2014
Valuation: $75,613.00 Constuction Type: 5B Entered By: RMA
Occupancy Group: Reference #: Plan Approved: 08/07/2014
# Dwelling Units: 1 Structure Type: Issued: 08/07/2014
Bedrooms: 0 Bathrooms: 0 Inspect Area:
Orig PC #: Plan Check #:
Project Title: GAUTHIER RES- ADD 68 SF @ 1ST
FLOOR FOR STAIRS, ADD 506 SF @ 2ND FLOOR FOR A BEDROOM &
BATHROOM
Applicant: Owner:
HEINZE CONSTRUCTION GAUTHIER THOMAS A&BECKY L
2501 JACARANDA AVE 2402 LA MACARENA AVE
CARLSBAD CA 92009 CARLSBAD CA 92009
760 310 2227
Building Permit $578.02 Meter Size
Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00
Plan Check $404.61 Meter Fee $0.00
Add'I Plan Check Fee $0.00 SDCWA Fee $0.00
Plan Check Discount $0.00 CFD Payoff Fee $0.00
Strong Motion Fee $7.56 PFF (3105540) $0.00
Park in Lieu Fee $0.00 PFF (4305540) $0.00
Park Fee $0.00 License Tax (3104193) $0.00
LFM Fee $0.00 License Tax (4304193) . $0.00
Bridge Fee $0.00 Traffic Impact Fee (3105541) . $0.00
Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00
BTD #2 Fee $0.00 Sidewalk Fee $0.00
BTD #3 Fee $0.00 PLUMBING TOTAL $68.00
Renewal Fee $0.00 ELECTRICAL TOTAL $43.00
Add'I Renewal Fee $0.00 MECHANICAL TOTAL $42.45
Other Building Fee $0.00 Housing Impact Fee $0.00
HMP Fee $0.00 Housing lnLieu Fee $0.00
Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00
Meter Size Master Drainage Fee $0.00
Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00
Red. Water Con. Fee $0.00 Additional Fees $0.00
Green Bldg Stands (5B1473) Fee $1.00 Fire Sprinkler Fees $0.00
Green Bldg Stands Plan Chk Fee $0.00
TOTAL PERMIT FEES $1,144.64
Total Fees: $1,144.64 Total Payments to Date: $1,144.64 Balance Due: $0.00
Insoector:
FINAL APPROVAL
Date: 3 -/L ff5' Clearance:
NOTICE: Please take NOTICE that approval of your project includes the Imposition' of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Storm Water Pollution Prevention Plan (SWPPP) Permit
08-07-2014 Permit No:SW140186
Job Address: 2402 LA MACERENA AV CBAD
Permit Type: SWPPP Status: ISSUED
Parcel No: 2550702100 Lot #: 0 Applied: 06/06/2014
Reference #: Entered By: RMA
CB#: C6141261 Issued: 08/07/2014
Inspect Area:
Project Title: GAUTHIER ADDITION Tier: 1
Priority: L
Applicant:
ERIC HEINZ
760 310-2227
Emergency Contact:
ERIC HEINZ
Owner:
GAUTHIER THOMAS A&BECKY L
2402 LA MACARENA AVE
CARLSBAD CA 92009
760 310-2227
SWPPP Plan Check $48.00
SWPPP Inspections $57.00
Additional Fees $0.00
TOTAL PERMIT FEES $105.00
Total Fees: $105.00 Total Payments To Date: $105.00 Balance Due $0.00
DATE CLEAFIM L Mr r
SIGNATURE,-,.--..
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING 0 ENGINEERING 0 BUILDING 0 FIRE 0 HEALTH HAZMATIAPCD
Building Permit Application Plan Check No.
( /
tt 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value
CITY 0 F Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. çe'p it ARLSBAD email: buiIdingcarlsbadca.gov
www.carlsbadca.gov Date jsw
JOB ADDRESS
21O
JUITE#/SPACE#/UNIT#
(I-
-
CT/PROJECT # LOT # PHASE # #OFUNITS
1-7.3-17 1
I#BEDROOMS 4 BATHROOMS i TENANT BUSINESS NAME I 0CC. GROUP
33
I CONSTR. TYPE
I DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
2 Tc? P RôcM I f3,0<-11-A coM \PPTtO Cv Jt,
s TO- 57 L s
Iwo
I PROPOSED USE
EXISTING U E
u) cE A&u' S1\M€
I GARAGE (SF) I
Lf3O
PATIOS (SF) I
I DECKS SF) I FIREPLACE
IYD# NO
ONDITIONING
YES NOE
FIRE SPRINKLERS
YES NO
APPLICANT NAME c PROPERTY 0 MEb/ i77-/ P,fnary Contact i ADDRESS, 5,n (
ADDRESS
CITY STATE ZIP
( P A
CITY
,
STATE ZIP
PHONE 7fi6 O-)T1 (FAX 7(6'7-(2 5 &CT7 PHONE ( L -t,237_ FAX
EMAIL
i—tzE (*5T (TiOt..(PbMAIL
EMAIL
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME
ADDRESS ADDRESS
GF 5ô 5pp (2/\N bi\ M
CITY STATE ZIP CFTY, STATE
PHONE FAX PHONE
7& 316 ;2? IFAX 17&,---
EMAIL EMAIL zJ (Ofl2UcOCI'J@G,,M(L. (C/V'
STATE LIC. # STATE LIC.#
CLAS
I CITY BUS. LIC.#
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuancej ao requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7005 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a Civil penalty of not more than five hundred dollars ($500)).
1L $:
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
[1 I have and will maintain :certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
[J I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. Policy No. Expiration Date
Thi action need not be completed if the permit is for one hundred dollars ($100) or less.
Certificate of Exemption: I certify thjn.tfti)erforman of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
alifomia. WARNING: Failure to S re prfers' compe sation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, alages as ovide for in Section"3706 of the Labor code, interest and attorney's fees.
£ CONTRACTOR SIGNATURE ( E] AGENT DATE 20/
In v L w AT ra
(hereby affirm that/am exempt from Contractor's License Law for the following mason:
[] I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
[J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
pr9perty who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's Ucense Law).
I am exempt under Section ______________Business and Professions Code for this reason:
I personally plan to provide the major labor and materials for construction of the proposed property improvement DYes DNo
I (have / have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name address! phone / contractors' license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address I phone / contractors' license number):
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address! phone I type of work):
PROPERTY OWNER SIGNATURE []AGENT DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? C3 Yes Cl No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Cl Yes Cl No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Cl Yes Cl No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
I cerlifythati have read the application and state thatthe above information is conectand thatthe information on the plans is accurate. I agree to complywith all City ordinances and State laws relatingto building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavatiojiy.er 50' deep and emolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Bwiflolng9ucial under the pro i ions of this Code shall expire by limitation and become null and vod if the building or work authorized by such permit is not commenced within
180 days from the date of such permi I thebel1ding orwortj authoriz by such permJs suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
.gAPPLICANT'S SIGNATURE / DATE - 7 - 1 4-
Inspection List
Permit#: CB141261 Type: RESDNTL RAD GAUTHIER RES- ADD 68 SF @ 1ST
FLOOR FOR STAIRS, ADD 506 SF @ 2ND
Date Inspection Item Inspector Act Comments
03/12/2015 19 Final Structural - RI
03/12/2015 89 Final Combo PD AP
01/21/2015 27 Shower Pan/Roman Tubs PD AP
12/11/2014 17 Interior Lath/Drywall PD AP
12/11/2014 18 Exterior Lath/Drywall PD AP
12/03/2014 84 Rough Combo PD AP
11/12/2014 13 Shear Panels/HD's PD AP
10/24/2014 15 Roof/Reroof PB AP
10/21/2014 15 Roof/Reroof MC NR AFTER STOP
08/25/2014 11 Ftg/Foundation/Piers PD AP
08/20/2014 21 Underground/Under Floor PD AP
Friday, March 13, 2015 Page 1 of 1
Carlsbad 14-1261
6/17/14
CITY OF
CARLSBAD
SPECIAL INSPECTION
AGREEMENT
B-45
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed
requires special inspection, structural observation and construction material testing.
'rojéctiermit:7 Project Address: 02 \) LA MAC&\
THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORIZED AGENT. Please check if you are Owner-Builder
D. (If you checked as owner-builder you must also complete Section B of this agreement)
Name: (Please print) -1( eS)Z(2
(First) (Mi) (Last)
Mailing Address: 5O( 3A \)t'& A'1 665IAt CA gao(
Email: 042 11RUC M .1 e 7CQ0 -2-Z-'7
I am: UProperty Owner roperty Owner's Agent of Record UArchitect of Record UEngineer of Record
State of California Registration Number Expiration Date:_________________
AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construction materials testing and,ff-site fabrication of building components, as prescribed in the statement of
special inspectionteon thpproved planInd, as required by the California Building Qode..
gignatur A Date:
CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder I owner-builder.
Contractor's Company Name: 14I t\l2C Cc)ll(12X,Tl cDt"S Please check if you are Owner-Builder D
Name: (Please print) E4 C_-
(First) (MI.) (Last)
Mailing Address: S2) Y'AePcpAAV CAgL/A C.k92639
Email: kbtI\IlE ( Phone7C 310 97.21
State of California Contractor's License Number: Expiration Date: Z_- '3$ -
Ict 5
I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the
building official;
I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports; and
I certify that I will have a qualified person within our (the contractor's) organization to exercise such control.
e: z ( Date:1- t
B-45 Page 1 of 1 Rev. 08/11
EsGil Corporation
In Partnership with government for cBui(&ng Safety
DATE: 7/21/14
JURISDICTION: Carlsbad
PLAN CHECK NO.: 14-1261
PROJECT ADDRESS: 2402 La Macarena Ave.
PROJECT NAME: Gauthier SFD ADD
U APPLICANT
U JURIS.
U PLAN REVIEWER
U FILE
SET: II
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil Corporation staff did not advise the applicant that the plan check has been completed.
EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Eric Heinze (I needed to contact him for a clarification).
Telephone #: 760 310-2227
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: 1) Per applicant, Will Foss will not require a soil report at this time for this 570
square foot 2 story project. Please verify and place soils stamp on the plans. 2) The red clouded
notes on sheets 2 (three notes) and 4 (two notes) need to be made on the City held sets.
Thank you.
By: Tamara Fischer Enclosures:
EsGil Corporation
El GA El EJ El MB El PC 7/14/14
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
EsGil Corporation
In Partners/lip with government for Building Safety
DATE: 6/17/14
JURISDICTION: Carlsbad
PLAN CHECK NO.: 14-1261
PROJECT ADDRESS: 2402 La Macarena Ave.
PROJECT NAME: Gauthier SFD ADD
SET: I
U .APPLICANT
ZZ JURIS.
U PLAN REVIEWER
U FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Eric Heinze
El EsGil Corporation staff did not advise the applicant that the plan check has been completed.
EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Eric Heinze Telephone #: 760 310-2227
Date contacted: (byY
O
) Email: heinzeconstructiongmail.com Fax
\&41
Mail Telephone Fax In Person
LI REMARKS:
By: Tamara Fischer Enclosures:
EsGil Corporation
DGA LEJ LIMB F-1 PC 6/9/14
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
Carlsbad 14-1261
6/17/14
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 14-1261 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2402 La Macarena Ave.
FLOOR AREA: 570 sq ft SFD ADD STORIES: 2
HEIGHT: 21 approx
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 6/17/14
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 6/9/14
PLAN REVIEWER: Tamara Fischer
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 14-1261
6/17/14
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning,
Engineering and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete.
. PLANS
All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code). Current set is signed.
Signatures will be verified on final set.
2. Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 2013 California Residential Code, which adopts the 2012 IRC,
2012 UMC, 2012 UPC and the 2011 NEC. Section R106.1. Note 8 on sheet I is
out-dated.
. FIRE PROTECTION
Please indicate on the plans whether the existing residence has a fire sprinkler
system installed. If so, then provide a note stating that any additions/alterations
will be provided with an automatic residential fire sprinkler system. Section
R313.2.
Please dimension the eave overhang on the southwest side of the addition.
Assuming the building is non sprinklered, eaves within 5' of the property line
must be one hour on the underside. (For a sprinklered building within 3' of the
property line). Sec R302.1.
Specify on the plans that any existing smoke alarms that are more than 10 years
old will be replaced. Section R314.3.2.
. GENERAL RESIDENTIAL REQUIREMENTS
Bathrooms and powder rooms must be mechanically ventilated (an openable
window won't suffice). Section R303.3.1 and CMC 403.7.
Carlsbad 14-1261
6/17/14
7. Glazing in the following locations should be shown on the plans as safety glazing
material in accordance with Section R308.4:
a) Glazing where the bottom exposed edge is less than 36" above the plane of
the adjacent walking surface of stairways, landings and ramps. Please
dimension or call out the height of the bottom of the window above
the landing if it is 36" or more, otherwise specify safety glazing.
EXITS, STAIRWAYS, AND RAILINGS
8. Provide stairway and landing details. Section R311.7.
Maximum rise is 7-3/4" and minimum run is 10", measured from the
nosing projection. Where there is no nosing, the minimum run is 11".
Minimum headroom is 6'-8".
C) Minimum width is 36".
d) The greatest riser height within any flight of stairs shall not exceed the
smallest by more than 3/8 inch. The greatest tread depth within any flight
of stairs shall not exceed the smallest by more than 3/8 inch.
9. A nosing (between 3/4" and 1-1h") shall be provided on stairways with solid risers.
Exception: No nosing is required if the tread depth is at least 11 inches. Section
R311.7.5.3.
10. Handrails (Section R311.7.7):
Shall be provided on at least one side of each stairway with four or more
risers.
Handrails and extensions shall be 34" to 38" above nosing of treads and
be continuous.
The handgrip portion of all handrails shall be not less than 11/4 inches nor
more than 2 inches in cross-sectional dimension. See Section R311.7.8.3
for alternatives.
Handrails projecting from walls shall have at least 1-V2 inches between
the wall and the handrail.
Ends of handrails shall be returned or shall have rounded terminations or
bends.
11. Every stairway landing shall have a dimension, measured in the direction of
travel, at least equal to the stairway width. If a door occurs at the landing, such
dimension need not exceed 36 inches. Section R311.7.6. Please dimension the
intermediate landing.
12. The walls and soffits of the enclosed usable space under stairs shall be
protected on the enclosed side with 1A-inch gypsum board. Section R302.7. (If
applicable).
Carlsbad 14-1261
6/17/14
. ROOFING
13. Please revise roofing approval number to ICC ESR 1900 and Specify Class A
roof per City Ordinance..
14. Specify on the plans the following information for the skylights, per Section
R106.1.1:
Manufacturer's name.
Product name/number.
C) ICC approval number, or equal.
. FOUNDATION REQUIREMENTS
15. Provide a copy of the project soil report. The report shall include foundation
design recommendations based on the engineer's findings and shall comply with
Section R401.4. The City of Carlsbad requires a soil report for all additions
exceeding 500 square feet and all 2 story additions (regardless of size).
Ensure that all recommendations in the soil report are incorporated into
the structural calculations and plans.
16. If the soils engineer recommends that he/she review the foundation excavations.
Note on the foundation plan that "Prior to the contractor requesting a Building
Department foundation inspection, the soils engineer shall advise the building
official in writing that:
The building pad was prepared in accordance with the soils report,
The utility trenches have been properly backfilled and compacted, and
The foundation excavations, the soils expansive characteristics and
bearing capacity conform to the soils report."
17. Provide a letter from the soils engineer confirming that the foundation plan,
grading plan and specifications have been reviewed and that it has been
determined that the recommendations in the soils report are properly
incorporated into the construction documents (when required by the soil report).
18. Please specify mm 2% slope at note #3 on sheet I per City policy.
19. Please detail retrofit hold downs and anchor bolts and reference to the
foundation plan.
. FRAMING
20. Please provide the remaining header sizes on the roof framing plan.
21. Please provide the following note per City policy: Nails for shear transfer
connection (using A35's, etc.) may not be driven parallel to the flanges of TJI's
(i.e., along the sides), per city policy, unless specific written approval from Trus-
Joist Macmillan is first obtained.
Carlsbad 14-1261
6/17/14
Some of the Column Bases called out on the foundation plan don't match the
post sizes.
Please show the rafters over the stairs on the roof framing plan.
Plans show a new sliding glass door at existing Family room. Please specify
whether it is being installed in an existing opening. If not, provide new header
size and address lateral resistance at that location.
Please reference detail for strapping above and below window at line 1 at the
upper level.
Unable to locate where blocked diaphragm specified on Li 1 is called out on the
plans.
The lateral calcs and the plans don't match at line 2 lower level.
Please add shear walls with nailing 4" o. c. and less to special inspection list on
Si and complete the enclosed City Special inspection form.
. MECHANICAL I ELECTRICAL I PLUMBING
Show on the plans the location, type and size (BTU's) of all heating and cooling
appliances or systems.
Every dwelling unit shall be provided with heating facilities capable of maintaining
a room temperature of 68 degrees F at a location 3 feet above the floor and 2
feet from exterior walls in all habitable rooms. Show basis for compliance. CRC
303.9.
Show on the plan the amperage of the electrical service, the location of the
service panel and the location of any sub-panels.
Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
Specify on the plans: Water conserving fixtures: New water closets shall use no
more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8
GPM, lavatories are limited to 1.5 GPM, and showerheads may not exceed 2.0
GPM of flow. CPC Section 403 and 408. Revise note 6 on sheet 2
Carlsbad 14-1261
6/17/14
Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407
. RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building
Standards Code which became effective January 1, 2011 and must be enforced by the
local building official. The following mandatory requirements for residential construction
must be included on your plans. CGC Section 101.3. The Standards apply to newly
constructed residential buildings, along with additions/alterations that increase the
building's conditioned area, volume or size. CGC Section 303.1.1. Provide a sheet on
the plans labeled "Green Building Code Requirements" and include the following
notes as applicable.
Storm water drainage/retention during construction. Note on the plans:
Projects which disturb less than one acre of soil shall manage storm water
drainage during construction by one of the following: A. Retention basins. B.
Where storm water is conveyed to a public drainage system, water shall be
filtered by use of a barrier system, wattle or other approved method. CGC
4.106.2.
Grading and paving. Note on the plans that site grading or drainage system will
manage all surface water flows to keep water from entering buildings (swales,
water collection, French drains, etc.). CGC 4.106.3. Exception: Additions not
altering the drainage path.
Note on the plans that landscape irrigation water use shall have weather or
soil based controllers. CGC 4.304.1.
Recycling. Note on the plans that a minimum of 50% of construction waste is to
be recycled. CGC 4.408.1.
Recycling. Note on the plans that the contractor shall submit a Construction
Waste Management Plan to the jurisdiction agency that regulates waste
management, per CGC 4.408.2.
Operation and maintenance manual. Note on the plans that the builder is to
provide an operation manual (containing information for maintaining appliances,
etc.) for the owner at the time of final inspection. CGC 4.410.1.
Carlsbad 14-1261
6/17/14
Pollutant control. Note on the plans that during construction, ends of duct
openings are to be sealed, and mechanical equipment is to be covered. CGC
4.504.1.
Pollutant control. Note on the plans that VOC's must comply with the
limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and
4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood
Products. CGC 4.504.2.
Interior moisture control. Note on the plans that concrete slabs will be
provided with a capillary break. CGC 4.505.2.1.
Interior moisture control. Note on the plans that the moisture content of wood
shall not exceed 19% before it is enclosed in construction. The moisture content
needs to be certified by one of 3 methods specified in Section 4.505.3. Building
materials with visible signs of water damage should not be used in construction.
The moisture content must be determined by the contractor by one of the
methods listed in CGC 4.505.3.
Indoor air quality. Note on the plans that bathroom fans shall be Energy Star
rated, vented directly to the outside and controlled by a humid istat. CGC
4.506.1.
Note on the plans that prior to final inspection the licensed contractor, architect
or engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions
from the Green Building Standards Code have been implemented as part of the
construction. CGC 102.3.
. ENERGY CONSERVATION
It doesn't appear that the new sliding glass door is included in energy calcs.
The CF1-R need the designer or owner's signature.
Show on the plans compliance with the residential energy lighting requirements
(Mandatory requirement):
In bathrooms, garages, laundry rooms, and utility rooms all fixtures must
be high efficacy style or be controlled by a vacancy sensor.
All other rooms require any installed fixtures to be high efficacy or be
controlled by a vacancy sensor or dimmer. (Closets under 70 square feet
are exempt).
C) Outdoor lighting fixtures that are attached to a building are required to be
high efficacy or controlled by a combination photo-control/motion sensor.
Carlsbad 14-1261
6/17/14
. MISCELLANEOUS
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes U No U
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Tamara Fischer at
EsGil Corporation. Thank you.
Carlsbad 14-1261
6/17/14
(DO NOTPAY— THIS IS NOTAN IN VOICE)
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 14-1261
PREPARED BY: Tamara Fischer DATE: 6/17/14
BUILDING ADDRESS: 2402 La Macarena Ave.
BUILDING OCCUPANCY: R3 / U TYPE OF CONSTRUCTION: VB
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
SFD ADD 570 131.73 75,086
Air Conditioning
Fire Sprinklers
TOTAL VALUE 75,086
Jurisdiction Code Icb IBY Ordinance
Bldg. Permit Fee by Ordinance _j
Plan Check Fee by Ordinance
Type of Review: E Complete Review
Other Repetitive Fee
Repeats Hourly ------1 LII
EsGul Fee
LI Structural Only
Hr. @ *
I $578.02 I
I $375.711
I $323.691
Comments: Additional 1/2 hour @ $86/hr = $43 for Cal green
Sheet 1 of 1
macvalue.doc +
PLAN CHECK
REVIEW
TRANSMITTAL
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
DATE: 06/23/14 PROJECT NAME: GAUTHIER RESIDENCE PROJECT ID: C8141261
PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2402 LA MACARENA AVE APN: 255-070-21
VA LUATION: 75,613 ADDITION
plarj cpØieview is complete and has been APPROVED by the ENGINEERING
si
By:
A Final Inspection by the Division is required Yes {No
>K This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
ONLY ITEMS MARKED X' NEED CORRECTION/CLARIFICATION
Plan Check Comments have been sent to: HEINZECONSTRUCTION@GMAIL.COM
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuancêof a building permit.
Resubmitted plans should include corrections from all divisions.
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
7606024610
ENGINEERING
7606022750
FIRE PREVENTION
7606024665
Chris Sexton
760-602-4624
Chris.sexton@carlsbadca.gov
/ Kathleen Lawrence
760-602-2741
Kathleen.Lawrence@carlsbadca.gov
Greg Ryan
760-602-4663
Gregory'Ryan@carIsbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
Cindy Wong
760-602-4662
CynthiaWong@carlsbadca.gov
Dominic Fieri
760-6024664
Dominic.Fieri@carIsbadcagov
Remarks:
11 Set#
Any outstanding issues will be marked with ( Make the necessary corrections for
T compliance with applicable codes and standards. Submit corrected plans and/or
specifications to the Building division for re-submittal to the Engineering division.
Items that conform to permit requirements are marked with i
1. SITE PLAN
Provide a fully dimensioned site plan drawn to scale.
Show:
SHOW 10' Tif' L2111 North arrow Driveway widths
PLANTl/' EJ LIJ Existing & proposed structures E1 EIJ Existing or proposed sewer lateral
EASy TAT
FRO T PRO LT E1111J Existing street improvements Liii] [iii] Existing or proposed water service
uic1i Liii Ll?i1 Property lines (show all dimensions) L.J Lii Submit on signed approved plans:
7 [lJ EEl Easements DWG No.
EEJ LIII Right-of-way width & adjacent streets
how on siteyI "
SHOW ON/' [1 [j'rainage patterns
PLAN H
,
p\JV =Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining
LOT 9RAINS street or an approved drainage course.
JAD9"iHE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale
SifOW ANY /way from building".
SLOPES [1 Existing & proposed slopes and topography
L13 =size, location, alignment of existing or proposed sewer and water service(s) that serves the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception.
Lii] LIII Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
JJ Site address
[ Assessor's parcel number
[7E Legal description/lot number
For commercial/industrial buildings and tenant improvement projects, include: total building
square footage with the square footage for each different use, existing sewer permits
showing square footage of different uses (manufacturing, warehouse, office, etc.) previously
approved.
LII LJ Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
Lot/Map No.: 33
Subdivision/Tract: CT 73-18
Reference No(s): 8145
E-36 . Page 2 of 6 REV 6/01/12
N/A
N/A
Set #
DISCRETIONARY APPROVAL COMPLIANCE
L_J L_J Project does not comply with the following engineering conditions of approval for project no.:
DEDICATION REQUIREMENTS
1fl Dedication for all street rights-of-way adjacent to the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $-24,00a—,-pursuant to Carlsbad Municipal Code Section 18.40.030.
For single family residence, easement dedication will be completed by the City of Carlsbad,
cost _$115.00.
E] Dedication required as follows:
IMPROVEMENT REQUIREMENTS
r1 All needed public improvements upon and adjacent to the building site must be constructed
at time of building construction whenever the value of the construction exceeds.
$124,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040.
=I L1 Public improvements required as follows:
Curb, gutter, sidewalk, underground utilities.
E] Construction of the public improvements must be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or current grant
deed on the property and processing fee of $ .444--so we may prepare the necessary
Neighborhood Improvement Agreement. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit. Processing fee $157.00.
LIII Future public improvements required as follows: CURB, GUTTER, SIDEWALK
UNDERGROUND UTILITIES
E-36 Page 3 of 6 REV 6/30/10
Set# 1
GRADING PERMIT REQUIREMENTS
The conditions that require a grading permit are found in Section 15.16 of the Municipal
Code.
j=Inadequate information available on site plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
remedial). This information must be included on the plans. If no grading is proposed
write: "NO GRADING"
EIJ ri Grading Permit required. NOTE: The grading permit must be issued and rough grading
approval obtained prior to issuance of a building permit.
LIJ E] Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector . The inspector will then
provide the engineering counter with a release for the building permit.
No grading permit required.
EIJ [ITII Minor Grading Permit required. See attached marked-up submittal checklist for project-
specific requirements.
MISCELLANEOUS PERMITS
EJ EiiiRIGHT-OF-WA'' PERMIT is required to do work in city right-of-way and/or private work
adjacent to the public right-of-way. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
L[I1Ei.] Right-of-way permit required for: Driveway
E-36 Page 4 of 6 REV 6/01/12
I
Set# 1
7. STORM WATER
COMPLETE
STORM WATER
FO
[$J 71 Project Threat Assessment Form complete.
EIJ Liii E osed Project Threat Assessment Form incomplete.
[J Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form
and return (SW 14-
LIIJ lJ Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Post-Devel ment (SUSMP) Compliance
L1
/,Storm
Water Standards Questionnaire complete.
LII Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign
the questionnaire and resubmit with next submittal.
[ Project is subject to Standard Storm Water Requirements. See city Standard Urban
Storm Water Management Plan (SUSMP) for reference.
htt://www.carlsbadca.Qov/business/buildinq/Documents/EngStandsw-stds-vol4-ch2. df
Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
ri Rainwater harvesting (rain barrels or cistern)
] Vegetated Roof
Li Bio-retentions cell/rain garden
LII Pervious pavement/payers
LIII Flow-through planter/vegetated or rock drip line
1J Vegetated swales or rock infiltration swales
[J Downspouts disconnect and discharge over landscape
Li Other:
E-36 Page of 6 REV 6/01/12
Required fees have been entered in building permit.
Drainage fee applicable
Added square feet
Added square footage in last two years? D yes Ono
Permit No.
Permit No.
Project built after 1980 yes Ono
Impervious surface >50% E,, yes LIIJno
Impact unconstructed facility Ejyes Lino
Fire sprinklers required Jyes jno (is addition over 150' from center line)
Upgrade [jyes Ono
No fees required
Set# 1
9. WATER METER REVIEW
Domestic (potable) Use
LIJIIJ [j What size meter is required?
EXJ [i] Where a residential unit is required to have an automatic fire
extinguishing system, the minimum meter size shall be a 1" meter.
NOTE: the connection fee, SDCWA system capacity charge and the
water treatment capacity charge will be based on the size of the meter
necessary to meet the water use requirements.
LIII EU For residential units the minimum size meter shall be 5/8", except where
the residential unit is larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be 3/4"•
10. AdditionaJ6nts
1.,P1SE MI0VE WATER METER IN FRONT OF PROPERTY LINE. WATER METERS
ARE I TV ROW.
SHOW EXISTING POOL.
Attachments: Engineering Application Storm Water Form Right-of-Way Application! Info. Reference Documents
E-36 Page 6 of 6 REV 6/01/12
CITY OF
01 STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
E-29
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carisbadca.gov
STORM WATER POLLUTION PREVENTION NOTES
ALL NECESSARY EQUIPMENT AND MATERIALS
SHALL BE AVAILABLE ON SITE TO FACILITATE
RAPID INSTALLATION OF EROSION AND
SEDIMENT CONTROL BMPS WHEN RAIN IS
EMINENT.
THE OWNER/CONTRACTOR SHALL RESTORE
ALL EROSION CONTROL DEVICES TO
'WORKING ORDER TO THE SATISFACTION OF
THE CITY ENGINEER AFTER EACH RUN-OFF
PRODUCING RAINFALL.
THE OWNER/CONTRACTOR SHALL INSTALL
ADDITIONAL EROSION CONTROL MEASURES
AS MAY BE REQUIRED BY THE CITY
ENGINEERING OR BUILDING INSPECTOR DUE
TO UNCOMPLETED GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY
ARISE.
ALL REMOVABLE PROTECTIVE DEVICES SHALL
BE IN PLACE AT THE END OF EACH WORKING
DAY WHEN THE FIVE (5) DAY RAIN
PROBABILITY FORECAST EXCEEDS FORTY
PERCENT (40%). SILT AND OTHER DEBRIS
SHALL BE REMOVED AFTER EACH RAINFALL.
ALL GRAVEL BAGS SHALL BE BURLAP TYPE
WITH 3/4 INCH MINIMUM AGGREGATE.
ADEQUATE EROSION AND SEDIMENT
CONTROL AND PERIMETER PROTECTION BEST
MANAGEMENT PRACTICE MEASURES MUST BE
INSTALLED AND MAINTAINED.
SPECIAL NOTES
STORM WATER COMPLIANCE CERTIFICATE
V My project is not in a category of permit types exempt from the Construction
SWPPP requirements
V My project is not located inside or within 200 feet of an environmentally
sensitive area with a significant potential for contributing pollutants to nearby
receiving waters by way of storm water runoff or non-storm water
discharge(s).
V My project does not require a grading plan pursuant to the Carlsbad
Grading Ordinance (Chapter. 15.16 of the Carlsbad Municipal Code)
V My project will not result in 2,500 square feet or more of soils disturbance
including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas that meets
one or more of the additional following criteria:
located within 200 feet of an environmentally sensitive area or the
Pacific Ocean; and/or,
disturbed area is located on a slope with a grade at or exceeding 5
horizontal to 1 vertical; and/or
disturbed area is located along or within 30 feet of a storm drain inlet, an
open drainage channel or watercourse; and/or
construction will be initiated during the rainy season or will extend into
the rainy season (Oct. 1 through April 30).
I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE
CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING
FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN
ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS.
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST
MANAGEMENT PRACTICES (EMPS) DURING CONSTRUCTION ACTIVITIES
TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE
MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE
THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED
POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH
THIS CITY APPROVED TiER 1 CONSTRUCTION SWPPP THROUGHOUT THE
DURATION OF THE. CONSTRUCTION ACTIVITIES UNTIL THE
CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF
CARLSBAD.
Ec fr6AIZ&
793AIN(S)/CWNE'S AGENT NAME (PRINT)
-- . --.-/O -(
'S AGENT NAME (SIGNATURE) DATE
PROJECT INFORMATION
Site Address: -tO2.. LA MkN
Assessor's Parcel Number: 2.SS7OZl XD
Project ID:(J'te) If(1/
Construction Permit No.: 6 (_'1/ 2/
Estimated Construction Start Date 72- -
Project Duration Months
Emergency Contact:
Name: 6tic t
24 hour Phone: 7CQ0 (0272-7
Perceived Threat to Storm Water Quality
Medium
If medium box is checked, must attach a site plan
sheet showing proposed work area and location
of proposed structural BMPs
For City Use Only
CIT V L4AD
STAND CRDI WPPP
Approved By
Date:,_______
E29 Page 1 of 2 REV 4/30/10
m
0
;3 I*' CD_ (0(Da)ITh QCD c 2.w0 0 < ,o (D (Vi. (DO CD _.O CD CD CL M CL
fn In
W a
-
z, g x!
CD)
(D(Doa0
o<
D. 33 8=
.; g (D0D4
Bt C=0 (D CD
a Cr
).•U
("o
S-3 ><i
-
U 0cgLg
CD 0(DO5(D'<Q
I fl)) -0Q.Xa
Oo 0 _. -fl ..CD< -
o--
:- 00 , (Dg •OO(D
_; OCL 1.D c0
.p_ (n q,
CD ) u
00 Ca OCD (A •C•C0
-.
C,- . CD-0 CD cD(D .,u,--,mCD
0.0 (DOmg0-
03 . ;0 &ri1
- _o 0_ Err aC
o = o am .
B -
a-g ;—-UO0.
. OOCD/C'°a
M - _-(D0<
w - (DO -0 CI) (D---,
! OB a C. (0 CD
- oo2° - C) CD -o CD(i' - .,
a C)
CD
g. CD CD
0
(A
£ 0 (0UCL iiUit.0 Cr (A (D 0 g ri -. 41 CD !C-? Geotextiles & Mats - ----------------
EC-8 Wood Mulching
Earth Dikes and
Drainage Swales
EC-1 1 Slope Drains
SE-1 Silt Fence
SE-3 Sediment Trap
SE-4 Check Dam Cl) a
X1 SE-5 Fiber Rolls
SE-6 Gravel Bag Berm
- - - — — - - - - - - -
- Street Sweeping and SE-7 Vacuuming
SE-8 Sandbag Barrier
SE-1 0 Storm Drain Inlet
Protection
TR-1 Stabilized Construction
Ingress/Egress 0-1
- - - - — - - - - - - - — - - -
- TR-2 Stabilized Construction 1 -
Roadway
NS-1 Water Conservation
Practices
N$-3 Paving and Grinding
w o
Operations CD
NS-7 Potable Water/Irrigation 30
---------------- ___
NS-8
_________
Vehicle and Equipment
WM-1 Material Delivery and
- - — - StorRn ---- - - - - - - - - ____
WM-2 Material Use
---------------- ___ __________
WM-3 Stockpile Management
---------------- ___
WM-4
________
5pm Preventlon and 03 Control 00 -----------_---- ___
WM-5 Solid Waste
Manacjpment CL _______
WM6 Hazardous Waste
Management
WM-8 Concrete Waste
Man2nPment
PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division
CITY OF REVIEW CHECKLIST 1635 Faraday Avenue
CAR (760) ' SBA D P 28 602-4610
L I - www.carIsbadca.ov
DATE: 7-14-14 PROJECT NAME: PROJECT ID:
PLAN CHECK NO: CB 14-1261 SET#: 2 ADDRESS: 2402 La Macarena APN: 255-070-21
This plan check review is complete and has been APPROVED by the Planning
Division.
By: Chris Sexton
A Final Inspection by the Planning Division is required Yes 0 No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: heinzeconstruction@gmail.com
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
760-602-4610
ENGINEERING
760-602-2750
FIRE PREVENTION
760-602-4665
Chris Sexton
760-602-4624
Chris.Sexton@carlsbadca.gov
Kathleen Lawrence
760-602-2741
Kathleen.Lawrence@carlsbadca.gov
H Greg Ryan
760-602-4663
Gregorv.Ryan@carlsbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
Cindy Wong
760-602-4662
Cynthia.Won@carlsbadca.ov
Dominic Fieri
760-602-4664
Dominic. Fieri@carlsbadca.gov
Remarks:
Plan Check No. CB 14-1261 Address 2402 La Macarena Av Date 7-14-14 Review #2
Planner Chris Sexton Phone (760) 602-4624
APN: 255-070-21 -00
Type of Project & Use: Net Project Density: DU/AC
Zoning: _____ General Plan: Facilities Management Zone:
CFD (in/out) #_Date of participation: Remaining net dev acres:_____
(For non-residential development: Type of land use created by this permit:
REVIEW #:
2 3 Legend: Z Item Complete Ij Item Incomplete - Needs your action
Environmental Review Required: YES NO 0 TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
• LI LI Discretionary Action Required: YES LI NO LI TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
0 El El Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES LI NO U
CA Coastal Commission Authority? YES 0 NO U
If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive,
Suite 103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
LI LI Habitat Management Plan
Data Entry Completed? YES LI NO LI
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of
Habitat Type impacted/taken, UPDATE!)
LI LI Inclusionary Housing Fee required: YES LI NO D
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES LI NO LI
(NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct
Housing Y/N, Enter Fee, UPDATE!)
LI LI Housing Tracking Form (form P-20) completed: YES LI NO D N/A LI
P-28 Page 2 of 3 07/11
Site Plan:
El El 0 Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes). Provide legal description of property and assessor's parcel number.
City Council Policy 44 - Neighborhood Architectural Design Guidelines
LI LI 1. Applicability: YES [I] NO LI
LII LI 2. Project complies: YES [II] NOD
I..
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required Shown 26"
Required Shown 67, 156"
Required Shown
Required 10' Shown
Required Shown
Accessory structure setbacks:
Front: Required Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Structure separation: Required Shown
Lot Coverage: Required <40% Shown 13%
Height: Required Q. Shown :'
0 El 5. Parking: Spaces Required 2 Shown Z
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
LI Z LI Additional Comments 1) Please show all existing improvements on the lot such as a patio
cover, (will the whole patio cover be demolished?), pool, etc. Please show the contours of
the lot on the site plan.
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Chris Sexton DATE 7-14-14
P-28 Page 3 of 3 07/11
(City of
Carlsbad
CERTIFICATION OF
SCHOOL FEES PAID
B-34
Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City
prior to issuing a building permit The City will not issue any building permit without a completed school fee form.
Project Name GAUTHIER RESIDENCE
Building Permit
Plan Check Number: CB141 261
Project Address: 2402 LA MACARENA AV RECEIVED
A.P.N 255-070-21-00
AUG 01 2014i
Project Applicant
(Owner Name): THOMAS & BECKY GAUTHIER CITY OF CARLSBAD
BUILDING DIVISION
Project Description: RESIDENTIAL ADDITION
Building Type
Residential: NEW DWELLING UNIT(S)
Square Feet of Living Area in New Dwelling/s
Second Dwelling Unit: Square Feet of Living Area in SDU
Residential Additions: 570 Net Square Feet New Area
Commercial/Industrial: Net Square Feet New Area
City Certification of
Applicant Information, Date 07/25/2014
SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD
F-1 Carlsbad Unified School District Vista Unified School District [J San Marcos Unified School District
8225 El Camino Real .1234 Arcadia Drive 2 5 .5 Pic o A V e Ste. 1 0 0
Carlsbad CA 92009 (760-331-5000) Vista CA 92083 (760-726-2170) San Marcos, CA 92089 (760-290-2649)
Contact: _Nancy _Dolce_ (By _Appt._Only)
Encinitas Union School District [J San Dieguito Union High School District-By Appointment Only
101 South Rancho Santa Fe Rd 684 Requeza Dr.
Encinitas, CA 92024 Encinitas, CA 92024
(760-944-4300 xl 166) (760-753-6491 x 5514)
Certification of Applicant/Owners. The person executing this declaration ("Owner) certifies under penalty of perjury
that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner
will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number
of dwelling units or square footage after the building permit is issued or if the initial determination of units or square
footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or
that the person executing this declaration is authorized to sign on behalf of the Owner.
Signature: Date:
B-34 Page 1 of 2 Rev. 03/08
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE
PROJECT HAVE BEEN OR WILL BE SATISFIED.
SCHOOL DISTRICT:
The undersigned, being duly authorized by the applicable School District, certifies that
the developer, builder, or owner has satisfied the obligation for school facilities. This is
to certify that the applicant listed on page 1 has paid all amounts or completed other
applicable school mitigation determined by the School District. The City may issue
building permits for this project.
SIGNATURE OF AUTHORIZED SCHOOL
DISTRICT OFFICIAL
TITLE
NAME OF SCHOOL DISTRICT
DATE
PHONE NUMBER qqq ')L iL(th
B-34 Page 2 of 2 Rev. 03/09
(City of
Carlsbad
CERTIFICATION OF
SCHOOL FEES PAID
B-34
Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City
prior to issuing a building permit. The City will not issue any building permit without a completed school fee form.
Project Name GAUTHIER RESIDENCE
Building Permit
Plan Check Number: CB141261
Project Address:
A.P.N
Project Applicant
(Owner Name):
Project Description:
Building Type
Residential:
2402 LA MACARENA AV
THOMAS & BECKY GAUTHIER ALLG 01 7014
i*i ii ulr1 '] 'IIi [•]
BUILDING DIVISION
NEW DWELLING UNIT(S)
Square Feet of Living Area in New Dwelling/s
Second Dwelling Unit: Square Feet of Living Area in SDU
Residential Additions: 570 Net Square Feet New Area
Commercial/Industrial: Net Square Feet New Area
City Certification of
Applicant Information: )'72g214 Date 07/25/2014
SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD
Carlsbad Unified School District D Vista Unified School District San Marcos Unified School District
6225 El Camino Real 1234 Arcadia Drive 2 5 5 Pico A v e S t e . 1 0 0
Carlsbad CA 92009 (760-331-5000) Vista CA 92083 (760-726-2170) San Marcos, CA 92069 (780-290-2649)
Contact: Nancy Dolce (By Appt. Only)
D Encinitas Union School District Z San Diegulto Union High School District-By Appointment Only
101 South Rancho Santa Fe Rd 684 Requeza Dr.
Encinitas, CA 92024 Encinitas, CA 92024
(760-944-4300 x1166) (760-753-6491 x 5514)
Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury
that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner
will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number
of dwelling units or square footage after the building permit is issued or if the initial determination of units or square
footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or
that the person executing this declaration is authorized to sign on behalf of the Owner.
Signature: Date:
B-34 Page 1 of 2 Rev. 03/09
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE
PROJECT HAVE BEEN OR WILL BE SATISFIED.
SCHOOL DISTRICT:
The undersigned, being duly authorized by the applicable School District, certifies that
the developer, builder, or owner has satisfied the obligation for school facilities. This is
to certify that the applicant listed on page 1 has paid all amounts or completed other
applicable school mitigation determined by the School District. The City may issue
building permits for this project.
SIGNATURE OF AUTHORIZED SCHOOL
DISTRICT OFFICIAL
TITLE
NAME OF SCHOOL DISTRICT
DATE
PHONE NUMBER
c
John Addleman
Director of Planning &
Financial Management
SAN Dij
72O- ?l3(Lc1/
B-34 Page 2 of 2 Rev. 03109
CB 14 1261 2402 LA MACERENAAV
(lITl-lIPPPPS. Ann lRSFt)1ST
Final Inspection required by
I Plan U CM&l,v Fire U
SW /L( /cl'h SUED Lim
Appr9ved Date By
BUILDING 77
PLANNING
ENGINEERING —' -/i I
FIRE Expedite? Y N
DIGITAL FILES Required? Y N
HazMat
APCD
Health
Forms/Fees Sent Recd Due? By
Encina
Fire
HazHeaIthAPCD
KYN
Schooi
Sewer
Stormwater V N
Special inspection (4 fl Ji '4 81 / IL1 V N tT:)
LandUse: Density: lmpArea:
CFD: Y N
FY: Annex: Factor:
PFF: V N
Comments-'Date Date Date Date
Building (,/, r1 r,(-
Planning
Engineering
Fire
Need?
)one
11 Done
U Done
610(/
71rollcl
eo-
f-7 J IL
n 44JV 6*/&i
c>
q /f-h b, OCvXk 7; £fl k)/cPtSJlL11 /
Cd1 pf2ijfèv14'(
7/23//' - rte-t LIO ,'
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
11-10-2014 Plan Check Revision Permit No:PCR14184
Building Inspection Request Line (760) 602-2.725
Job Address: 2402 LA MACERENA AV CBAD
Permit Type: PCR Status: ISSUED
Parcel No: 2550702100 Lot #: 0 Applied: 10/29/2014
Valuation: $0.00 Construction Type: 5B Entered By: RMA
Reference #: Plan Approved: 11/10/2014
PC #: Issued: 11/10/2014
Project Title: GAUITHIER RES-CHANGE WINDOWS Inspect Area:
IN MASTER BEDROOM- W/ STRUCT & ENERGY CALCS
Applicant: Owner:
ERIC HEINZE GAUTHIER THOMAS A&BECKY L
2501 JACARANDAAV 2402 LA MACARENA AVE
CARLSBAD CA 92009 CARLSBAD CA 92009
760 310-2227
Plan Check Revision Fee $125.00
Fire Expedited Plan Review $0.00
Additional Fees $0.00
Total Fees: $125.00 Total Payments To Date: $125.00 Balance Due: $0.00
FINAL APPROVAL
Inspector: Date: Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
(cityof
Carlsbad
PLAN CHECK REVISION
APPLICATION
B-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
r4 A
Plan Check Revision No. L\ \ Original Plan Check No.
Project Address 2/02 LÀ MICke&A AV Date
Contact tE-C 1SN7_ Ph Ro03tO Fax760 cO07
Email H?J' Co j (P (1\AA I L C0 N\
Contact Address 29b1 AW kVt5 Zip
General Scope of Work Lt r'.. tO'ti CfS(€
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised:
1 Plans Calculations Soils LKEnergy Other
2.
Describe revisions in detail
3.
List page(s) where
each revision is
shown
4.
List revised sheets
that replace
existing sheets
1?E -d
Does this revision, in any way, alter the exterior of the project? Yes No
Does this revision add ANY new floor area(s)? LI Yes No
Does this revision affect any fire related issues? Yes No
S. Is this a F-1 Yes 'J No
£Signature
1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602- 27 19 Fax: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov
EsGil Corporation
In cPartnersliip with government for Building Safety
DATE: 11/6/14
JURISDICTION: Carlsbad
PLAN CHECK NO.: 14-1261 Rev (PCR14-184) SET: I
PROJECT ADDRESS: 2402 La Macarena Ave.
PROJECT NAME: Revisions to Gauthier SFD ADD
LI APPLICANT
LI JURIS.
LI PLAN REVIEWER
U FILE
Lii The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
jIj1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil Corporation staff did not advise the applicant that the plan check has been completed.
EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: Fax #:
Mail Telephone Fax In Person
REMARKS: 1) The revised sheets need to be slipped into the originally approved plans
(Both sets). 2) The CFI-R on sheets T24.1 and T24.2 of the originally approved plans
needs to be crossed out and note added to the owner set held at the city (as I have done
and clouded in red on the transmitted originally approved set). Thank you.
VY"
By: Tamara Fischer Enclosures:
EsGil Corporation
LI GA LI EJ LI MB [1 PC 10/30/14
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
Carlsbad 14-1261 Rev (PCR14-184)
11/6/14
[DO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 14-1261 Rev
(PCR14- 184)
PREPARED BY: Tamara Fischer DATE: 11/6/14
BUILDING ADDRESS: 2402 La Macarena Ave.
BUILDING OCCUPANCY: R3 /U
BUILDING
PORTION
AREA
[ (Sq. Ft.)
Valuation
Multiplier
J Reg.
Mod.
VALUE ($)
Revisions
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code Icb f By Ordinance
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance "1
Type of Review: LI Complete Review LI Structural Only
I I
I $125.00I
LI Repetitive Fee
Repeats
* Based on hourly rate
Li Other
Hourly I Hr.
EsGil Fee $100.00 I $100.001
Comments: Sheet I of I