HomeMy WebLinkAbout2405 GRANADA WAY; ; CB881436; Permit'G)
USE BALL POINT PEN ONLY & PRESS'HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
-
2r 0 I hereby affirm that am licensed under
ui 'provIeIona of Chapter 9 (commencing with
SsctIon 7000) of DivIsIon' 3 of 'the Business
'5_and Professions Code, and my license is,I_ J L-fuIi force and effect. -
I hereby aifirm that I am exempt Iron, the Contrac tot's License'Law lot the following reason (Sec. 7031 .5 Business and Professions Code: Any city or county which re- - quires a permit to construct, alter, improve, demolish. or
repair any Structure, prior toils issuance also requires the ap-
plicant for such -permit to file a signed statement that he is
licensed pursuant to the provisions of the contractors
- License Law (Chapter 9 commencing with Section- 7000 of
Division 3 of the Business and Professions Code) or that Is OX' • - empt therefrom and the basis for the alleged exehiplion. Anyi
violation of Section 7031,5 by an applicant for a permit sub' • lects the applicant to a civil penalty of not more than live ban
dred dollars ($500).
It I. as owner of the property. or my employees with wages
- "as.their sole compensation, will do the work. and the struc'
'''lare is not intended or offered tsr sale (Sec., 7044. Business
and Protessioos.Code: ,Tbe Contractor's License Law-does
- - not apply to an owner of property who builds or improves
thereon and who 0000 such work himself or through his own
- 'empinyees, provided thal'such improvements'are' not intend-'
UI ed or offered to, sale., It however the building or improve- Z mont is sold within one. year olcornpletion;lhe owoet'builder
39 will have the burden of proving that he did not build or im -
prove for the purpose of sale).
- %1 1 - I, as ownirt he property, am exclusively contracting
'With licensed contractors to construct the project (Sec. 7044,
Business and Professions Code: . The Contractor's Liceose
- Law does not apply to an owner.of property who builds or im-
proves thereon, and Aho contracts for each projects with a
contractor(s) license pursuant to the Contractor's License Law).-
• - I') As a, homeownor lam improving my home, and the follow'
"- O9 Conditions exist: ' -. ' ' -, - ' ' I - . ' . ' SI The work is being performed prior to sale.
I have lived 'in my_'hn.me$tor twelve months
-- prior to completion 01 this work. -
I have not claimed this exemption during the
last three years.
Otmexempf,Jndor.Sec. . for this reason - - -
-."
0 thereby affirm thatl have a certificate of consent to
'selt.insure. or certificate or Workers Compensation In.
surancO.or a cerrified copy thereof Sec. 3800. LabOr Code) -
—POLICY NO.
MPANY .1 ' - .
110- 0 Copy It with thcity,.4
0 'Certified copy is hereby tarnished
IL
" LU
'''C •:
' " 'CERTIFICATE OF EXEMPTION FROM
C) --,WORKERS' COMPENSATION INSURANCE $4 ' 'IThis section need not be completed it the permit u
IX • is tAr one hundred dollars 1010010, 10551 -
le
C5 I certify that i,thepArtormance 01 the work for which
cc ,' this permit is issued. I shall not employ any person in any 0 ' manner so as to become subject to the Workers Compen. 'I
salon Laws of California. -
, NOTlCTO 'APPLICANT it, alter making this Certificate I .01 Eoemption.,yoa shouldbecome subject to the workers
.Coriiperisatibn'-piovisiOns ot,thA Laborode. yoannost(
'torthwith comply with such provisions or this permit shalt r. he deered revuked.I 'I •
- -
:.'
0 -1 hereby attire, that Ihem is construction lending-f
LLI agency Ir the' performance 01 the work for which Ibis per'
ol mit is issued-ISec? 3097. Civil Codet. "
ZI WI Leoder's Name .
-.. -- ' . - • Lender's Address_________________________________
— CARLSBAD BUILDING DEPARTMENT APPLICATION '2075 Las Palmas Dr., Carlsbad, CA 92009-1915 (619)438-1.161 - - - --- -- . — 'S--' --' ' 5 .--
JOB ADDRESS ' AV. ST. RD. THOMAS BROS NO. DATE OF APPLICATION BUSINESS LICENSE tt VALUATION PERMIT NUMBER
A4. 11A
LOT BLOCK SUBDIVISION ASSESSOR PARCEYNO.
1 H I /7 25(0
CONTRACTORS PHONE - / ZONE ' ' -
. -- -- OWNER'S NAME - OWNE R'S PHONE - ,To i+& 'D P-iuc1IJE '14'_ .1r—O 7 2-q_?1 70
CONTRACTOR'S ADDRESS STATE LICENSE NO. BUILDING SO. FOOTAGE
OWNER'S MAILING ADDRESS
.2Loc 'et WPJ ) Ct> ..
. DESIGNER DESIGNER'S PHONE
OESCRrPON OF OR K4 . . .9 4153 01/16/89 0001 01.. 02
DESIGNER'S ADDRESS STATE LICENSE NO. BldPmt 226.0
F/P FLR ELEV.I NO OCCGP EDU
- ._-' STORIES
YND
- --S-- ••, ' - . - CENSUS TRACT PARKING SPACE - RES UNITS GRADING PERMIT ISSUED REDEVELOPMENT TVP 0CC LOAD 'FIRE SPR
-. - '"• t.,,' AREA , coj)
Y Na" N , V YO No. - Not Valid Unless Machine Certified
QTY, -PLUMBING PERMIT -ISSUE - QTY. - MECHANICAL PERMIT- ISSUE ,i,ç oo - SUMMARY/ACCOUNT NUMBER ' a
'EACH FIXTURE TRAP -' - ' INSTALL FURN. DUCTS UP TO100.000 BTU. BUILDING PERMIT 001-810-00-00-8220 /5
/ EACH BUI'CUIJG SEWE'R •' ._ _. ' OVER 100,000 BTU , 'SIGN PERMIT 001-810-00-00-8221
EACH WATER HEATER AND/OR VENT . - . , BOILER/COMPRESSOR UP TO 3 HP -, . - PLAN CHECK . - 001-810-00-00-8891
EACH GAS SYSTEM ITO 4 OUTLETS . - BOILER/COMPRESSOR 3.15 HP - TOTAL PLUMBING 001-810-00-00-8222
-
EACH GAS SYSTEMS OR MORE - , METAL FIREPLACE - . - -- - .- - ELECTRICAL ' - 001410700-00-8223
/15 .
-
EACH INSTAL., ALTER, REPAIR WATER PIPE -. ., VENT FAN SINGLE DUCT - MECHANICAL . - - 001-810-00-00-8224
EACH VACUUM BREAKER - - . ,
-
ME CH EXHAUST H000IOUCTS . - MOBILEHOME 001-810-00-00-8225
WATER SOFINER -
- -- ' RELOCATION OFEA FURNACE/HEATER I '. SOLAR - - - 001-810-00-00-8226
EACH ROOF DRAIN (INSIDE) - , DRYER VENT . • . .. STRONG MOTION 880-519-92-33
- - - - •-
TOTAL MECHANICAL
...- -- . -.
- -
0-c)
I -
. -
FIRE SPRINKLERS 001-810-00-00-8227
I TOIAL PLUMBING ,: PUBLIC FACILITIES-FEE - --320-810-00-00-8740
- - - BRIDGE FEE 360-810-00-00-8740
CITY; - .,.- ELECTRICAL.PERMIT - ISSUE OTY. MOBILE HOMESETUP - -.
' ----------_
PARK-IN-LIEU (AREA I
- NEW CONST-EA AMP'SWT BKR' - - ------ - I CAR PORT I - - , - - - - - TIF - -. ' - - - 312-810-00-00-8835 - - -
-1 PH -, - 3 PH- - . - - , AWNING - , LA COSTA TIF 311-810-00-00-8835
EXIST BLDG EA AMP/SWT/BKR - . GARAGE - . . . . FMF
- 1 PH j.- - 3 PH- -. - -- - . - - ' , - - - - - - ... . - -- .LICENSE.TAX - - -001-810'00-00-8162
REMODEL'ALTLR' PER CIRCUIT - - -
'' . ' 40 - . . '
- MIFF 880-519-92'57
-
TEM'PPOLE 200 AMPS '( - ______________________ ___________
OVER 200 AMPS
TEMP OCCUPANCY (30 DAYS)
- -- • " ', ,. '" - ;::-; ., CREDITrDEPOSIT. . -' :..'-ge -.
- TOTAL ELECTRICAL
I
I- I IOTA) - TOTAL FEES PAYABLE - i..
I HAVE CAREFULLY EXAMINEDTHE COMPLETED "APPLICATION AND PERMIT- AND DO HEREBY Expiration. Every permit issued by the Building Official under the provisions 'Of this' —* 'AN OSHA PERMtT IS REQUIRED FOR EXCAVATIONS OVER - -
CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE ode shall expire by limitation and become null and void If the building or work 50" authorized by such permit is not commenced within 180 days from the date of Such DEEP AND DEMOLITION OR CONSTRUCTION OF
DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS permil, or if the building Or work authorized by such permit is WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON suspended or STRUCTURES OVER 3 STORIES IN HEIGHT
ISSUED: TO COMPLY abandoned at any time Allen the work is commenced 10,8 pB od STRUCTION.,,WHETHEIT SPECIFIED HEREIN OR NOT, I ALSO AGREE TO SAVE INDEMNIFY AND , KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND,APPLICANT'S NATURE 0 NER
WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
CONTRACTOR 0 - / DATE
EXPENSES
01180 days
APP 'ED BY -- — - - -
BY PHONE 0 GRANTING OF THIS PERMIT ••,-'--e-
'I.
00.1
FINAL
PLUMBING
ELECTRICAL
MECHANICAL.
GAS 1• s.-r
BUILDING
SPECIAL CONDITIONS
TYPE , DATE INSPECTOR
BUILDING
FOUNDATION
REINFORCED STEEL'
MASONRY
GUNITEORGROUT - -.
SUB FRAMED FLOOR LJ,CEIIAING
SHEATHING' D ROOF 0 SHEAR-
FRAME
EXTERIOR LATH'
INSULATION
INTERIOR LATH & DRYWALL
PLUMBING - -
Li SEWER AND BL/CO Li P1/CO
UNDERGROUND 0 WASTE LIWATER
TOP OUT Li WASTE Li V/ATER ...-. -
TUB AND SHOWER PAN •- -• -- -
GAS TEST
D WATER HEATER 'Li SOLAR WTER
ELECTRICAL
o ELECTRIC UNDERGROUND DUFFER
ROUGH ELECTRIC '.• L -'l.Y .Vi¼
Li ELECTRIC SERVICE 0 TEMPORARY
Li BONDING 0 POOL
MECHANICAL
O DUCT & PLEM., 0 REF. PIPING
HEAT — AIRCOND.SYSTEMS
VENTILATING SYSTEMS
CALL FOR FINAL INSPECTION-WHEN ALL APPROPRIATE
. S ,• S.
FIELD INSPECTION RECORD . • -.
- REQUIRED SPECIAL -INSPECTIONS S INSPECTOR'S NOTES •- -.
INSPECTION
-
REQ. IF INSPECTOR'S DATE h%4m IpVi* T1 o- CHECKED
SOILS COMPLIANCE (
PRIOR TO --
FOUNDATION INSP - -. •
- - - - —
STRUCTURAL CONCRETE f
OVER 2000 PSI - — 5- - - • - *
PRESTRESSED .. -. :.- -S ,_3 — --- - -- - • - -• -- - — --5---- - —
CONCRETE
POSTi TENSIONED
-CONCRETE --- - - ' -- - - • -
FIELD WELOING —
-
HIGH STRENGTH
BOLTS - -. -.
SPECIAL MASONRY - - .• .• . -- - - " - - -
PILES CAISSONS • . S • - - .. t- S — - —
— - • _. - - - - - - -
• ____ ______
.5
-
----'-- : -
S3O .' ••\-. _____ ________ _____ -
. - .. - •__)
!4g. 'J'IVI '/4
S • ' - - ;_ S • -
- *4 —
- - ...* •- .._:-- , - S
Thomas Engineers
Consulting Engineers • Land Surveyors
1036 Commerce Street, Suite B •San Marcos, CA 92069
(619) 471-8889 March 27,1989
City of Carlsbad
Building Department
2075 Las Palmas
Carlsbad, CA 92008
Attn: Building Inspection' - -
Subject: Van Dyke remodel, Granada Way.
Dear Sir-or Madam:
I have reviewed our structural calculations for the
above-referenced project and have determined that the contractor
may skip-sheet the roof in accordance with the Uniform Building
Code instead of solid sheeting as called for on the building
plans. The building lateral loads are adequately distributed
-
without the need for solid roof sheeting.
If you have any questions regarding the above please don't
hesitate to give me a call.
Sinc6re1' :
THOMAS ENGINEERS
Ca~vidM. ~Thom~~s,
FP
RCE
56
cc
o
- - - -1-
1Ii1L.I U)tt1Utt%11U1N
9320 CHESAPEAKE DR, SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: APPLICANT
JJ SD ICI
JURISDICTION: /7 .~(O ECK
-F1FILE COPY
PLAN CHECK NO: ''/4/36 'SET: - .' UPS
• EJDESIGNER :PROJECT ADDRESS: WA -
PROJECT NAME: _jJ DYfrCE DD,TipflL
. The plans transmitted herewith have been Co ected where
necessary and substantially comply with the jurisdiction's
.builditig codes.
.:The planstransmitted herewith will substantially comply -• -
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff. •
S *
The plans transmitted herewith have significant deficiencies El identified on the enclosed check list and should be corrected
- and resubmitted for a complete recheck.
• D The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
-
jurisdictiontô return to the applicant contct person.
The applicant's copy of the check list has been sent to
I. • -.
. Esgil staff did not advise ,the applicant contact person that
plan chek has been completed.
Esgil staff d1d advise applicant that the plan check has
been completed. Person contacted:
Datecontacted: Telephone #______________
REMARKS: I F PO S,4S
C A.)/Wb.
-.
y By: Enclosures: iLM) I
t~ZIL •
'3
53
ESGIL CORPORATION
- .. - -, 9320 CHESPE.KE DR.. SUITE 208
SAN DIEGO,CA92123
(619) 360-1468
DATE:A NT
RIION
JURISDICTION:. CITY, OF. CARLSBAD P.LN—Cf!ECKER
DFILE COPY
PLAN CHECK NO: . SET: UPS
0 DESIGNER
'H PROJECT ADDRESS:
PROJECT NAME Wri) D K i1 Dir/,J -
-- The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
S.-. with the jurisdiction's building codes when minor deficien-
cies identified - are resolved and
...checked by building department staff.
- The plans transmitted herewith have significant deficiencies
0 identified on the enclosed check list and should be corrected
and resubmitted for acomplete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgi]. Corp. until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
-jurisdiction to return to the applicant contact person.
'The applicant's copy of the check list has been sent to:
1ov 7?9,' jv,,Jc7 57
:S4 9a
Esgil staff did not advise the applicant contact person that
., plan check has been completed.
4
Esgil staff did advise applicant that the plan check has -0 been completed. Person contacted: RY LEi
Date contacted Telephone #.2?9-c2s5.3
.7
'REMARKS: ,5/i'73. ,3 9 N--ve £6e1) pi -i-,
ENCL:VJE BY:
S ESGIL CORPORATION -
•:. -.
/'J'3/-1?
'•p '
t
-
pui c : ?i NO eo
JuRISDIcrI:CITYOFCAM—WD
:-
1
, Q
S .
-Ds 5 _Pj.Jp1,q L&)MV
i?S
PlAN (aocI( JlKPr
- CITY OP CARLSBAD
SDI(1 FAMILY AND DUPLEX ThL
Date plans received by jurisdiction:
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National •.
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present California law mandates that residential,
construction comply with Title 24 and the following
model codes:
1985 UBC (eff. 7/31/87)
1985 UPC (eff. 3/30/87)
1987 NEC (eff. 10/28/87) -
1985 UMC (eff. 8/28/87)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
The circled items listed need clarification,
modification or change. All items have to be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1985 Uniform Building Code, the approval .of
the plans does not permit the violation of any
state, county or city law.
To sneed up the recheck process, note on this list
(or a copy) _where each correction item has been
addressed i.e.. plan sheet, specification, etc. Be
sure to enclose the marked up list when you submit
the revised plans .
Date plans received by Esgil Corporation:
Date initial ilan check completed:
By:____________________
Applicants contact person:
Telephone:__________________
z'PAGR XEMMS ARE MT IN SEQMM AS PAGES RAVMIMMS XMMING COMMMCKS W
List No. 63, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1985 UBC)
-
- .
1.
PLANS
Please make all corrections on the original
..../' tracings and submit two new sets of prints, and
any original plan sets that may have been
j returned to you by the jurisdiction, to:
oP.
, Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
- -. (619) 560-1468.
-. 2. Please make all corrections on the original
-.--".i tracings and submit two new sets of prints,
and any original- plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
.Indicate on the Title . Sheet of the plans, the
name of the legal. owner and name of person
responsible for the preparation of the plans.
Section 302(a)7.
All sheets of plans must be signed by the
.. person responsible for their preparation.
' I (California Business and Professions Code).
Plans, specifications and calculations shall be
Signed by the California state licensed
'. engineer or architect responsible for their
- . preparation, for plans deviating from
conventional wood frame construction. Specify
expiration date of license. (California
Business and Professions Code).
•.
. Specify on the Title Sheet of the plans the
- ( - gross floor area of each element of this
project including dwelling, garage, carport,
patio, deck and balcony. Section 302(c).
7". Provide a statement on the Title Sheet of the
plans that this project shall comply with Title
24 and 1985 UBC, UMC and UPC and 1987 NEC.
'submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of. all cut or
fill slopes. Show finish floor elevations and
show elevations of adjacent finish grade.
Show drainage patterns with minimum slopes.
Section 302(c).
Indicate distance from property lines to
1 proposed building. Section 302(c).
Show on the title sheet all structures, pools,
walls, etc. included under this application.-
.Any portion of the project shown on the site
plan that is not included with the building.
permit application filed should be clearly
identified as "not included."
ILl. Clearly show if the lower level is a basement
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
the distance to the floor above, for story
determination.
FIRE PROTI0N
Walls closer than 3 feet to property lines
(
shall be one-hour rated construction, have no
openings, and shall have 30 inch parapets when
the building floor area exceeds 1,000 square
feet on any floor.
(Table 5-A, Section 1709 (a)).
l. Projections, including eaves, may not extend
f
more than 12 inches into the 3 foot setback
from the property line. Eaves over required
windows shall be not less than 30 inches from
the side and rear property lines. Section
1710 and Section 504. (a) and (b).
It Plastic skylights shall not be installed
/ within 8' of an exterior wall located where
openings in such exterior wall are prohibited
or required to be protected.
Section 5207 (a)7.
1. Projections, including eaves, shall be one-.
I hour fire-resistive construction, heavy timber
or of noncombustible material if they project
into the 3' setback area from the property
line. Section 1710.
Show' location of permanently wired smoke
detector, centrally located in corridor or
area giving access to sleeping rooms or above
stair if sleeping rooms are on upper level.
Section 1210.
4. A smoke detector shall be installed in the
basement of dwelling units having a stairway
which opens from the basement into the
dwelling. Such detector shall be connected to
a sounding - device or other detector to provide
an alarm which will be audible in the sleeping
area. Section 1210.
18. When the valuation of a room addition exceeds
$1,000, or when sleeping rooms are created,
smoke detectors shall be provided at existing
bedrooms per item 16 above.
12/16/87 •
-
•
•
2
d -
3.PrOvide stairway and landing details. Section
3306 (b)
&(c).
-
a. Maximum.rise is 7" and minimum run is 11".
When the stairs serves less than 10
occupants, or serves an unoccupied roof,
rise may be 8" maximum and run 9" minimum.
b. Minimum headroom is 66".
c Minimum width is 36".
H handrails per Section 3306 (j), shall J satisfy the following:
Provide handrail for stairways with 4 or
.' - more risers..
Handrail shall be 30" to 34" above the
-'-' nosing of treads.
The handgrip portion of handrail shall be
not less than 1 1/4" nor more than 2" in
cross-sectional dimension.
Every stairway landing shall have a dimension,
measured in the direction of travel, at least
equal to the stairway width. Such dimension
need not exceed 36 inches. Section 3306 (g),
3304 (i).
£/2. A door may open inward at the top step of a
stairway provided the top step is not more than
7 1/2" lOwer than the floor level. Section
3304 (h).
44. Provide details of winding stairway complying
with Section3306 (d):
a. Minimum tread is '6 inches at any point and
minimum 9 inches at a point 12 inches from
where the treads are narrowest.
b. Maximum rise is 8 inches.
C. Minimum width is 36 inches.
Provide spiral stairway details, per Section
3306 (f):
Minimum run is 7 1/2 inches measured at a
; point 12 inches from where the treads are
the narrowest.
Maximum rise is 9 1/2 inches.
C. Minimum headroom is 6 feet 6 inches
d. The tread must provide a clear walking
area measuring at least 26 inches from the
-. outer edge of the supporting column to the
inner edge of the handrail.
Spiral stairways may not be used for required
exits when the area served is greater than 400,
sq. ft. Section 3306 (f).
Provide I.C.B.0. Research Report and number
for metal stairway, or submit plans and
calculations and approved fabricator
registered with the building department or
note that the stairway fabrication plans shall
be submitted to and approved by the building
official prior to installation.
97. In buildings over 2 stories in height, provide
3/4 hour fire-rated assemblies for all
openings in the exterior -wall below or within
10 feet horizontally of an exterior stairway.
An exit balcony with 2 separated stairways is
exempt. Section 3306 (1).
48. Openings in exterior walls below or within 10
feet, measured horizontally, of an exterior
stair shall be protected by self-closing fire
assemblies having a three-fourths-hour fire
protection rating when the stair serves a
floor level having openings in two Or more
floors below it. An exit balcony with two
separated stairways is exempt.
Section 3306 (1).
4. Exterior stairways shall not project into the.
f 3 foot setback from the property lines.
Section 3306 (n).
5t). The walls and soffits of the enclosed usable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Section 3306
(m).
5k.. Within units, show that corridors have - a
minimum width of 36 inches. Section 3305 (b).
Specify roof slope.
. Roof slope is not adequate for roof type / specified. Table 32-B; Section 3203 (h).
Specify roof material and application.
Chapter 32.
1. Specify I.C.B.0. or U.L. approval number for
I roof materials not covered in U.B.C., e.g.,
tile, etc. Section-107.
12/16/87 -
-
4
' _': '•' .. 'V..
I'
-V
The naxirxiurn slopefor afire re.ardant built- /9. Show 'a min' 2" air space and flashing
f. up roof, with rock or,gravel surfacing, is 3 between planter and building walls.
..inches' in 12 inches. Section 3203 (e) 2. Section 2516 (c) 7.
- • : --"minimum The . minimum,slope for. a fire retardant-built- GARAGE AND CARPORTS • , up roof, with cap sheet surfacing, is 1/2 inch - ,
'in 12 'inches.' Section 3203 (e)3. 7. Garage requires one-hour fire protection on •
Specify minimum 1/4inch per foot roof slope
the garage side of walls and ceiling common to
the dwelling. Table 5-B, Section 503 (d).
- - for drainage or design to support accumulated
water. Section 3207 (a), Section 2305 (f) and 7/L. All elements supporting floor above garage,
Section'2511 (d) 6. , ' including walls supporting floor joists, must , --
.. ' - have one-hour fire-resistive protection on the
..- Show roof drains and overflows. Section 3207. garage.side. Section 503 (b) -
i). Show 1 3/8" solid core self-closing door for
60
Provide skylight details to show compliance
with Sections 3401 and 5207 or provide I.C.B.0. openings between garage and dwelling. SectiOn
approval number. 503 (d).
Plastic skylights must- be separated from each 7. Garages are not permitted to open into a room -'
other by at least 4 feet. Section 5207 (a) 6. used for sleeping purposes. Section 1104.
Show attic ventilation. Minimum vent area is 91,1/1,50
14
of attic area or 1/300 of attic area if
An occupancy , separation is not required
I between carport and residence, provided the
at le.ast'SO% of the required vent is at least 3 ' carport is open on two or more sides and has
'feet above eave vents or cornice vents. Show no enclosed uses above.
' required area and area provided. Section 503 (a) Exception 3. ' *
' Section 3205 (c). '
" / 7/. Show garage framing sections, size of header
MASON over garage opening, lateral cross bracing at
6/.,'.'Pr'ovide fireplace construction details or note
plate line, method bracing garage front and
holddowns if required. chapter 23.
construction to be per attached fireplace
standard drawing. chapter 37. NOTE: Maximum shear panel ratio is 3 1/2 to 1
for height-to-width . Table 25-I.
4. Show anchored veneer support and connections
attached to wood in Seismic Zones 3 and 4, J6. Doors may open into the garage only if the
comply with Section 3006 (d)1 and Section 2515 floor or landing in the garage is not more'
-.,(a). Show ties and 99 -wire in horizontal than one inch lower than the door threshold.
joints. t 1 - -, ' Section 3304 (h). .
#V I •- .- '. E. Show height and construction details of all ' S Provide an 18" raised platform for any FAU,
masonry walls. chapter 24. ' '' water heater, or other device in the garage
which may generate a flame or spark. UMC
E. Note that cleanout openings shall be provided Section 508, UPC Section 1310 (a).
at the bottom of all cells to be grout filled
in accordance with Table 24-G. Cleanouts shall FOUNDATION KUiK?XIS
be sealed before grouting, after inspection.
Show floor and roof connections to masonry
Per soils repOrt, note on the plan the soils
classification, whether or not the soil is
walls. Connection shall resist 200 pounds per expansive and note the allowable bearing
lineal .foot or the actual design load, value. Section 2905 (c).
whichever is greater. Cross grain -tension or
: bending in wood ledgers is not permitted. 7. The foundation plan does not comply with the
Sectjon2310 & 2312 (j)3A. soils report recommendations for this project. .,
- • Please review the report and modify design,
notes and .details as required to show 6t. Provide details for damp proofing the
foundation walls, below finish grade, where compliance:
usable space exists on the interior side of the V
. wa1ls.' Section 1707 (d). , V
V
• '<. .a• ,'- • -
V ,
'*•
I'
-•
*V, . - V ' V
f
- V
12/16/87 5
'V •• ' - •V'J• V
+ '-I
- p
V - '
- - -
4. ., .
6. Provide notes on the'foundation plan listing
the soils report recommendation for
foundations, slab and building pad preparation.
Provide a letter from the soils engineer
confirming that the, foundation plan; grading
plan and specifications have been reviewed and
that it has. been determined that the
recommendations in the soils report are
properly incorporated into the construction
documents '(when required by the soil report).
The soils report recommendations excavations be
revie'ed by soils engineer.' Note on the
foundation plan that "Prior to the contractor
requesting' a Building Department foundation"
inspection, the soils engineer shall advise the
building official in writing that:
1 The building pad was prepared in
accordance with the soils report,
2. . -The utility trenches have been properly
backf ii led and compacted, and
'..., . 3: The, foundation excavations, formings and
reinforcements comply with the soils
' report and approved plan."
s '• Show height of all foundation walls. chaptr
fe. Show height of "retained earth on all foundation
walls. Chapter 23.
If cut or fill slopes exist, show distance of
foundation to edge of cut or fill slopes and
show. steepness and heights of cuts and fills.
Chapter 29.
86. Note 'on plans that wood shall be 6" minimum
above finish grade. Section 2907 (a).
Note on plans that surface water will drain away from building and show drainage pattern
and key elevations. 'On graded sites, the top
of any exterior foundation shall extend above
the street gutter at point of discharge or the
- - inlet to a drainage device a minimum of 12"
plus 2 percent. Section 2905 (f), 2907 (d) 5.
'Dimension foundation per U.B.C. Table 29A:
Floors . - - Footing
Supported* Stemwall Width Depth Thickness
'1 . 6" 12" 12" 6"
2 ' 8" * 15" 18" 7"
• 3 10" 18" . 24" 8"
Foundátions may support a roof in addition to the
floors. Where only a roof is supported, use
foundation for one floor.
. I•* •
.
:'•A 5,.
V
4. Show foundation sills to be pressure treated,
or equal. Section 2516 (c) 3.
?6. Show foundation bolt size and spacing.
Section 2907 (f). .
'Specify size, I.C.B.0. number and manufacturr
of power driven pins. Show edge and end
distances and spacing.
Section 302 (c).
If required by structural calculations, show
size, imbedment and location of hold down
anchors on foundation plan. Section 2312 (f),
302- (c). V
note on plan that hold down anchors must be
tied in place prior, to foundation inspection.
Section 305 (e) 1. 'V
Show adequate footings under all bearing walls / and shear walls. Section 2907 (b). ., .
Show on the plans stepped footings for slopes,
steeper than 1:10. Section 2907 (c). -
9/. Show minimum 18" clearance from grade to
bottom of floor joists and minimum 12"
clearance to bottom of girders. .
Section 2516 (c) 2.
0. Show pier size, spacing and depth into
undisturbed 'soil. Table 29-A.
Show minimum underfloor access of 18" x 241,1.'
Section 2516 (c).
Show minimum underfloor ventilation equal to 1
sq. ft. for each 150 sq. ft. of underfloor -
area. Openings shall be as close to corners
as practicable and shall provide cross
ventilation on at least two approximately
opposite sides. Section 2516 (c) 6.
l9). Specify that posts embedded in concrete shall -
/ :be pressure treated per UBC Std. No. 25-12.
Section 2516 (c) 1.
FRA
Show wall bracing. Every exterior wood stud
wall and main cross partition shall be braced
at each end at least every 25 feet of length
with 1 x 4 diagonal' let-in braces or
equivalent. Section 2517 (g) 3.
X2. Note cross bridging or blocking. Floor joists
, and rafters 12" or more in depth shall be
supported laterally by bridging at intervals
not exceeding 8 feet, unless both edges are
held inline. Sec. 2506 (h), 2517 (a) 6.
- F •' . -
12/16/87 ' . ' 6
... , .,
1Qshow.blockingat ends-and at supports of floor
:1. joistS, rafters and trusses at exterior walls.
-; Section 2517 (d) 3, 2517 (h) 6.
04-Show double joists. Floor joists shailbe
doubled under bearing partitions running
parallel with the-joists. Section 2517 (d) 5.
5: Bearing partitions, perpendicular• to joists,
shall not be offset from supporting girders,
.be.anis, walls or partitions, more than the depth
0. of the joist. Section 2517 (d) 5.' -
14:Showrafter ties: -.Rafter ties shall be spaced
/. . not . more than .4 feet on center and be just - . above the ceiling joists, where rafters and
:ceiling joists are not parallel. Section 2517
*.(h) 4.. '...-
4 .1 • ,
Show rafter purlin braces to be not less than
.45 -: degreesto the horizontal.
Section 2517 (h) 5.
1718.' Show 1/2" minimum clearance between top plate
.' of interior partitions and, bottom chord of
'.trusses. (To ensure loading will be as
designed) .-
1 '9. 'Show double* top plate with minimum 48" lap
splice. Section 2517 (g) 2.
i;. Sho'w nailing will be in compliance with Table
111.
l] Show, 0r note fire , stops at the following
locations per Section 2516 (f):
.,In concealed spaces of stud walls and
partitions, including furred spaces, at
- the ceiling and floor levels-and at 10
..,foot -intervals . along the length of the
s wall,
() atá11 . interconnections between concealed
I vertical, and-horizontal spaces such as
'occur at soffits, drop ceilings and cove
ceilings; -.
In concealed ' '.spaces between - stair
stringers at the top and bottom of the run
''- 'and between studs along and inline with
the run of stairs if the walls under the
-----stajrsare unfinished; and
in openings around vents, pipes, ducts,
chimneys, fireplaces and similar openings
which, afford a passage for fire at ceiling
and floor levels, with noncombustible
- • materials.
-,. ._ . - , .• ,'-, I , *
lX2. Show stud size and spacing. Maximum allowable
I stud heights: Bearing wall: 2 x4 and 2 x 6
max. 10'; Non-bearing: 2 x 4 max. 14', 2 x 6
max. 20'. Table 25-R-3.
/3- Studs supporting two floors, , a roof and *
ceiling must be 3 x 4 or 2 x 6 at 16" O.C.-
Table 25-R-3. - -
4. Note on A.I.T.C. Certificate of Compliance for
/ glued laminated wood members shall be given to
the building inspector prior to installation.
Section 306 (f).
45. Detail all post-to-beam and post-to-footing
connections and reference- the detail to the
plan. Section 2516 (ci).
116. Detail shear transfer connections, including
roof and floor diaphragms, to shear walls.
Section 2513. .
D117. Specify nail size and spacing for all shear
walls, floor and roof diaphragms. Indicate
required blocking. Maintain maximum diaphragm
dimension ratios. '' ITables 25 I, 3, K and
Section 4713 (d)]. OOIZ1L)C'I
1t8. Show 3" x 4" or 2" x 6" studs in first story
f of three story building. Table 25-R-3.
l9. Provide truss details and truss calculations
I for this project. Specify, truss
identification numbers on the plans.
120. Provide roof framing plan and floor framing
S
plan. Section 302 (c). .SMi £PbEreL)GL)
Ttao& jsirs.
1. Provide framing sections through - -
Section 302 (c).
LVI
3.12. Specify all header sizes for opening over 4'
/ wide. Section 2517 (g) 5. 900 Fl- 00R._
i6. Provide calculations for main vertical and -
I horizontal framing members and post footings.
- Section 302 (b).
114. Provide calculations for lateral loads, shear
panels, shear transfer and related. Section
302 (b).
ci .1
cV4
4..
: I V -
Show bn the plans all structural requirements
- - developed - in the structural calculations.
Section- 302 (c). (See comments below or at
16. Columns and posts located on concrete or
masonry floors or decks exposed to the weather
or to water splash or in basements and which
upport permanent structures shall be supported
by concrete piers or metal pedestals projecting
above floors unless approved wood of natural'
resistance to decay or treated wood is used.
;t Section 2516 (c) 4.
7.:Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
- ' decay or treated wood is used.
Section 2516 (c) 4.
1. Show location of attic access with minimum size
22" x 3011 . Section 3205.
ShoCi draft separation for attic areas between
.-'units in a duplex. Section 2516 (f).
130. Specify plywood grade and: panel identification
-index. Table 25-N.
'When roof pitch is leis than 3:12, design ridge
as abeam. Section 2517 (ii).
2. If foundation.cripple wall studs are less than
14" high, framing shall be solid blocking.
' Section 2517 (g) 4.
Cripple wall studs exceeding 4 feet in height
shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 42 stories.
4 ?-Section 2517(g) 4. V
14. Show plywood sheathing over exposed eaves, or
other weather exposed areas, is exterior grade.
Section 2516 (i). -
. ]5 Show a weep screed at the foundation plate line
on all exterior stud walls to be stuccoed.
4_ .Secti0n4706 (e)'.
46..Detail truss layout for 30" x 30" attic access,
- if required for equipment in the attic.
17.-Ridges, hips, and valleys shall be at least .one
size larger than supported rafters. Section
2517 (h) 3• •V -
18. In open beam construction, provide strap ties
•'I across the beams at the ridge support. Section
2501
•.
: . .. -
V
)ANICAL (UNIFORM )AN1CAL CODE) -.
All heating, ventilating, and cooling systems and,
appliances shall comply with the Uniform Mechanical
0
Code. V
1'9. Show the size, location and type of4 all
heating and cooling appliances or systems.
10. Show source of combustion air to furnace, per
Chapter 6, UMC.
1Le,2. Every dwelling unit shall be provided with
( heating facilities capable of maintaining a V
room temperature of 70 degrees F. at 3 feet -
above the floor in all habitable rooms. Show
basis for compliance. UBC, Sec., 1211.
1L2. Show minimum 30" deep unobstructed working '
( space in front of furnace. Section 505, UMC.
1l3. Note on plans, "clearances to, be per
manufacturer's listing." Section 504, UMC. V
14. Furnace shall not be installed in any bedroom;
f bathroom or in a closet or confined space with
access only through such room unless
specified as direct vent appliance, enclosed V
furnace or electric heating appliance. V
Section 704 UMC. *
l5. Show I.C.B.0. approval number for prefab
/ fireplace.
46. Show access to the attic or underfloor furnace
to be minimum 30 inches by 30 inches.'
Section 708 & 709 UMC. .'
l/.7. Note that passageway to the attic furnace
shall be unobstructed and have continuous
solid flooring not less than 24 inches wide.
Section 708 UMC. V
V
iLe. Show permanent electrical outlet and lighting
fixture controlled by a switch for the attic' V
furnace. Section 708 UMC.
149. Show details to comply with Section 709, for
furnace under the floor,, or Section 710 for
V roof or outside furnace.
15k. Note on plan: Gas vents and non-combustible -
piping, in walls, passing through three floors V
or less shall be effectively draft stopped at
each floor or ceiling. V
UBC, Section 1706 (a) 6.
ll. Provide dryer vent to outside. UMC, Section
I 1903.
5.
- V - • '
-
..'
1
AU energy items shown on the plans must be in
agreement . with the information shown on the
' properly completed Form CF-1R.,
•
~
2. Specify on the bui1ding plans all of the
mandatory energy conservation requirements as
listed on the enclosure tit1ed,. "Mandatory
- Energy Conservation Requirements".
1113. Show the make, model and efficiency of the
space heating (or cooling) system and provide
- heat loss calculations if the Output exceeds
- 45,000 BTU/Hr.
1)4. For room additions;show that the glazing area
of the addition does not exceed 16% of the
newly-conditioned floor area, plus glazing
. removed or relocated due to the addition.
1 5. See additional corrections below or at end.
• •' - CARLSBAD S.F.D. & DUPLEX SUPPLEMENT
3/6.. Energy conservation design should be for Zone
hI
7 -. . See attached energy packages.
7 -Floor drains must .have auto-prime (city
_policy).
. -i18...Nóte exhaust fans cannot be ductless type (city
policy).
179. New residential units must be pre-plumbed for
(- -future solar water heating. Note "two roof
* , jacks must be installed" where the water heater
1-1 j is in the one story garage and directly below
the most south facing roof (City Ordinance No.
- $093).
18q. Note "two 3/4" copper pipes must be installed
f to the most convenient future solar panel
'4 location when the water heater is not in a one
story garage and is not directly below the most
south facing roof. (City Ordinance No. 8093).
11. All piping for present or future - solar water
I
heating must be insulated when in areas that
are not heated or cooled by mechanical means
(city policy)
- . -
( P.:ft 'D
Incorporate the waterproofing details, on the
attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
13. Show on the Title Sheet on the plans, the
I information required by the attached
Developmental Services Sheet 112383.
184 All new residential buildings, including.
additions, require a soils report. Please
submit two copies. VR. DMA iJ U.ThJVEm l.b*t
18. Heavy timber framing, minimum 6" x 10" beams
and minimum 8" x 8" post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptable if shown on the plans. (city
policy). -
l8. UBC Adopting Ordinance 8792 requires Fire
4I Retardant roof on all structures (Sec.
18.04.230). Show compliance with UBC Section
3203(e).
147. City Ordinance 9792 requires two parking
spaces/unit with clear area of 201 x20' i.e. no
washing machines, etc. Show compliance.
i8. Please see additional corrections, or remarks,
I on the following page. -
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number
of 619/560-1468, to perform the plan check for your
project. If you have any questions regarding these
plan check items, please contact_________________
JEFJ
at Esgil Corporation. If you have any questions
regarding City Building permit procedures, please
contact Carter Darnell at the City of Carlsbad,
1200 Elm Avenue, telephone 619/438-1161.
Thank you.
Enclosures: -
1.
3.
£ 4V WEC AkF! i) Em., £ ik- .JDr E .# (L)Fo. PhDi, , e .',ei) TWP?J
10
•- •-
•. ..., -••.• • V . -• - •' -
El
,
r - -
- Datei I1—-
Prepared by*
':- ::..•. L-
CITY OF CARLSBAD
VALUATION AND PLAN CHECK FEE
Bldg. Dept.
0 Esgil
- PLAN CHECK NO. 2/V3,
BUILDING ADDRESS2AS A"o"P WAY
APPLICANT/CONTACT R PHONE NO '7 ff -s
BUILDING OCCUPANCY 1.3 DESIGNER PHONE____________
TYPE OF CONSTRUCTION V)J CONTRACTOR PHONE__________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
06
1 )575•.p I57_ _______________
_____•1 __________ ______
Air Conditioninz
Commercial
Residential
Res. or Comm.
Fire SDrinklers
Total Value
Building -Permit Fee S i i5.Oc)
Plan Check Fee S _$99v5
t
CON MCTS
Plans received by Esgil after July 31, 1987 shall have permit and
plan,chéck fees calculated per 1985 UBC.
SHEET / OF / 12/87
4 . I
ENGINEERING CHECKLIST
w LEGEND • :i Date: Item Complete • Plan Check No.
Item Project Address: 21ôs_G,v'o'_i,4v Incomplete - Needs t Action
Project Name: VDy _/Iomrrô,
FieldCheck Date 1,2,3 Number in circle
indicates plancheck
By number that deficiency
was identified
- LEGAL REQUIREMENTS
.•f -
.
4
-'
> .-> Site Plan
/E:
1 Provide a fully dimensioned site plan drawn to scale Show North
••. arrow, property lines, easements, existing and proposed [ structures, streets, existing Street improvements, right-of-way
width and dimensioned setbacks
2 Show on Site Plan Finish floor elevations, elevations of finish
/ grade adjacent to building, existing topographical lines, existing LA E El and proposed slopes, driveway and percent (%) grade and drainage
patterns
-
bCh p,
El 3. Provide legal description of property.
4 Provide assessor's parcel number.
PERMITS REQUIRED
Grading
0 5. Grading permit required. (Separate submittal to Engineering
- Department required for Grading Permit).
6 Grading plans in plan check PE___________
7 Need the following completed prior to building permit issuance
Li ' Li A Grading plans signed
Grading permit issued.
Grading completed.
Certification letter and compaction reports submitted.
E Grading inspected and permit signed off by City Inspector.
LiE 8. Right-of-Way Permit required for work in public right-of-way
- (e.g., driveway approach, sidewalk, connection to water main
etc)
P*' 49. Industrial Waste Permit application required. To be filled • out
• completely and returned to Development Processing. *
••• 1 -*
-
• - -
-.
--- •• -- -- .- --
FEES REQUIRED
0 10. Park-in-Lieu fees required. -
Quadrant: - , Fee Per Unit: - , Total Fee:
-.11. Traffic impact fee required. ,•t., r Fee Per Unit: Total Fee /
j 12. Bridge and Thoroughfare fee required.
Fee Per Unit: , Total Fee: AYY 0 13 Public facilities fee required
I!1'D 0 14 Facilities management fee required Fee Ah
15 Additional EDU's required
/ Sewer connection fee:. - SeweO permit no. .
' 16 Sewer lateral required
REMARKS
•_-.•_*4 ' -
-4 • 4 - - - - •, ••
:-.
-
O K to issue ate
"If you have any questions about any of the above items identified on this plan
check, please call the Development Processing Department at 438-1161
-*4--
F
• -•
4 1
-4..-.- - - - - - - .- -.,
- .._.*
- -
• •-
:--
a., • ....-
r4
PLANNING CHECKLIST
V7 CO -00 00
- Plan Check No. 88/13o Address r7R'3sc39 j4/9y
. .! - Type of Project and Use m or—c
•
>
Zone Use Allowed? YES NO
Setback Front olc Side O(< Rear
-a. eL ; Facilities Management Zone 2.
School District: San Dieguito Encinitas
- - Carlsbad San Marcos
' Discretionary Action Required YES NO
Environmental Required YES NO
"EJ D Landscape. Plan Required YES NO (
Comments
Coastal Permit Required YES NO
LI: LI .D Additional Comments
-•- - .
4
4
DEVELOPMENT PROCESSING SERVICES 61VISION
2075 LAS PALMAS DRIVE
CARLSBAD, CA 92009-4859
I (619)438-1161 $ I)
MISCELLANEOUS FEE pi1r V&
Applicant Please Print And Fill In Shaded Area Only CA
-
DDRESS PLAN ID NO
ASSESSOR r *
PARCEL NO :.:
_______________________________
2729 10/27/88 0001 01 05 Kc
OWNER S 00
MAILING $tf
ADDRESS
VALIDATION AREA
CONTRACTOR'W -t_ dReVa1 ESTMATED VALUATION _______________ S
CON ga TRACTC
MAICf PLAN CHECK FEE
IF THE APPLICANT TAKES NO ACTION
WITHIN 180 DAYS, PLAN CHECK FEES
ITEL WILL BE FORFEITED
S STATE S 'JBUSIN ESS
LICENSE 0
_41 WE,
CHECK IF SUBMITTED
2 ENERGY CALCS
0. 2 1987 ENERGY CALCS
FOR _NON _RESIDENTIAL _BLDGS
2 STRUCTURAL CALCS DESCRIPTION OF WORK j opiE -
2SO S SOILS REPORTS S6 6
2 SELF ADDRESSED ENVELOPES
ei i2\LLATtc S S
DATE GIVEN! DATE SENT TO APPLICANT
011
CONTACT PERSON LA LA COSTA LETTER
2II12 SCHOOL FEE FORM ADDRESS
S
,S
S •
TEL.7 —O
P& ECORRECTIONS LIST
..
CERTIFICATE OF OCCUPANCY S
S
DAT
White File Yellow - Applicant Pink - Finance Gold - Assessor
,r Page Three
u1Y14, 1977 Job No.: 6-20
Conclusions and Recommendations . ,.
The expansion potential of the onsite soils that will directly
- affect shallow foundations and slabs is considered moderate
. . for lots 1,, 7-9, 11-16, 19-24, 26-38, 46-54, 57and 69.
Remedial construction measures to minimize this condition are
recOmmended as follows:'. . •.
Tooting shall be continuous under all exterior and interior bearing
'.walls and shall be. imbedded a minimum depth of 18 inches below the
lowest adjacent finished grade Reinforce the continuous footings
with a minimum of one #4 rebar placed top and bottom
Concretefloor slabs shall be reinforced with 6X6 - 10X10 welded
mesh placed at midpoint in the slab. Floor slabs shall be .
cast on 'a 4 inch thick layer of graded aggregate base course or
washed concrete sand.
Garage floor slabs need not be reinforced If poured entirely inde-
pendent of the stem walls using a positive expansion joint of felt
:or similar approved material. . • .
*
The recommended soil bearing value for continuous and square footings
a minimum of 12 inches In width and imbedded a minimum ii depth of 12
inches below the lowest adjacent finished grade shall be 1500 P.S.F.
The foregoing values are for dead and live loads and may be increased
1/3 for temporary horizontal forces.
is the opinionof this firm that the fill soils placed on the
subject site,;as reported herein, have been properly compacted for
?their intended use. . . .
.
Respectfully submitted,
- . DUCC ENGINEETL NC, INC. i Approved by:
Hprvey Dutjre nej . • Sterling F/chite RCE 10863 :