HomeMy WebLinkAbout2408 MAJANO PL; ; CB890102; Permit"' z C ;:: .. a: ~ 0 ..
C
~[ i
a: '" C -' s ~ '" z ~
•
z 0 a z '" .. :I 0 0
"' 0: '" " a: 0 J:
i[
, USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
~hereby aHlrm that I am llcensed under
provisions ol Chapter 9 (commencing with
S.Ctlon 7000) of OIYlslon 3 of the Business
and Profusions Code, and my license 1s 1n
full force and effect
I nereby athrm mat I am e~empt 1,0.,, me ConlroL
ror s license Law •or the 1ol•owrng reason 1sec 7031 5 Business and Professions CIXle Any city or couniy wh,U, re qu,res a perm II to construct alter. ,,.,p,ove demol,s~ or
repa,r any struclure pr,or to ,ts ,ssuance also requires !heap
p11canl tor such per<>11! to t,1e a s1~ned stalement that ne ,s
',censM pursuant 10 the prov,sjons ol rne cowac:or ~ ucense Law !Chapter 9 commencmg w,1n Setlron 7000 01
J,v,sron 3 of the Business and Protess,ons Code, O' I hat,, ex
empt therefrom and the bas,; for lhe allegea e,e'11pr,on ~n)' v101a11n, oi Sec!,on 7031 5 by an applicant 'or a perm,, sub
;eels the 0001,ca"! to a c,v,! pena'!\· o' not ,.,ore :han 1,·1e ~u~ dred d[,llars 1S~001
I as '1W~er ol me o<ooerty Jr my employee> w,t~ wa~es
as !heir sole compensation w1li do lhe work a"d !ie struc tve •S ~01 ,nrenOM or olfered lor sa,e 1Sec 7044 Bus,nes;
and Proless,ons Code Tne Con1ractor s License I aw does nol app1y to an owner ot proper!y w~o builds or improves
thereon and who does such work hof'",sel1 or lhrough his own
emp:oyees. pro.:ded that such ,,,.,provements are not intend ed or olfered 10, sale 11. Mwever. lhe tiu,ld,ng or ,mprove
ment 1s sold w1th,n one year of comple1,on the owner-bu•lder will have the !Jurden of proving that he did not ~u1td or ,m wove lor :~e purpose of sale,
I, as owner of lhe pro~erty, am exclusively con1ract1~g w1rh licensed contractors !o construct the pro1ect {Sec 7044
Busmess and Professions Code The Contractor's license Law does not apply lo an owner ot property whG builds or rm•
proves Thereon. and who conlr.icts for each pro1ects w,th a con1rac1or[s) license pursuanl lo the Contractors L•cense Law)
As a homeowner I am ,mprov1ng my home and lhe follow ,ng cond1t1ons ex,st
1 The work ,s being pertormed pr,or 10 sale
2 I have lived m my home ior twelve months prior 10 complet,on of !his work I have nol claimed lh,s exemption dur,ng the
last lhree years
~r 11h~: r~~~:t under Sec _____ _ B & PC
:!/2ereby af11rm thal I nave a cer11ticate ot consent to
sell-msu,e. o, a cert,hcate of Workers Compensation In•
su,ance. or a cert,lied copy the,eo' 1Sec 3800 labor Code)
POLICY NO
COMPANY
~P\' 1s f,leC with 111e c,ty
~ Certil1ed COPY IS he•eby furnished
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
1Th1s sec1,on need nol be completed 1! \he perm,1
,s for one hundred dollars 1$1001 or less) = I certrfy that 1n the perlormance of the work for wti,cn
lh1s permit 1s issued. I sl1all not employ any pe<son 1n any
manner so as to become sub1ect to 111e Workers Com pen
sa11on Laws of California
NOTICE TO APPLICANT: 11. af!er mak,ng this Certificate
I
(
I
of Exempt,on. you sl1ould become sub1ec1 lo !he Workers
Compensation p,ov,s,ons of the Labor Code. you must
forthwith comply w,th such pro.is,ons or th,s perm,1 shall I
be deemed revoked
_eby attirm that there 1s a construct,on tending I
CARLSBAD BUILDING DEPARTMENT APPLICATION & PERMIT 2075 Las Palmas Dr., Carlsbad, CA 92009-1915 (619) 438-1161
J08 4DOJl!:SS , . _ ,,, , AV.ST.RO. TH~BROSNO . OATE,OF APPUCATION BUStNE~ l.lC~N~E # VALUATION PERMIT NUMBER d; _L Af? . .. _,,;, ,;4 'J,;t A/ 0 ~··· . ·-2--27..:s• . -ACJF 7/,?f ~ ~/t?P.. L(?T I !f(OCK I SUBOIVJSION 1 AS~~~ELJ°e-1-os .,,d:5 .. CONTRACTOR ~ CONTAACTOflS PHONE,# ZONE
OVIINEONAME . I 0~'£~'S PHONE OQ·•'_;." .J......, ._ .... tt'f 1,,.7472-
r{\.LC,O\.,n,. CONTRACTOR'S ADORES$ tit.;, +tQ
STATE LICENSE NO. e, BUILDING SQ. FOOTAGE
.. b 9, 9..r_ .,.?. .,.1,.-::77 /OP--OWt'\IEA'S'MAIL!NG,ADDRESS CJ ,
. !:) 4 /\P., ffi.f\: ,..., A..,,.,;.,; uL DESIGNER
Q ~ 1\) ru f\
QEsiONEA'S PHONE
A""\~---OESCRIPT10'N~~ "YORJ(. ' ' . ... 16. ' K' . · .. DESIGNER'S ADDRESS ' 57 AlE LICENSE NO.
/vtd:r . JI,, .. J AJ/l_. <St\~~ .. . .. . 5045 02/27/89 0001 01 02
' ' FLA ELEV NO IT3 E.9"1 BldF'mt 1.1540; STORIES ,c ,.a--" (./
I CENSUS TRACT I PAPK<NG SPAC[ RES UNITS GRADING PERMIT ISSUED I REDEVELOPMENT -~
OCC LOAD FIAE SPP ,✓ AREA 1.,.-V ,□ ,O ,R""'"' v0 Nr.i..,,, Not V;,lid Un~r Milchme Certified
QTY PLUMBING PERMIT· ISSUE 1. .so QTY. MECHANICAL PERMIT· ISSUE /,5 zio SUMMARY/ACCOUNT NUMBER
EACH FIXTURE TRAP INSTALL FURN DUCTS JP TO 100.000 BTU t:IUllli11~ci tTMIV I] vu 1 -~ 1(J-UU-00-8uL --EACH i:lUILOING SEWER OVER 100,000 BTU SIGN PERMIT 00 1-81 O · 00-00-8221
EACH WATER HEATER ANO OR VEN 1 80ILER1COMPRESSQR UP TO 3 HP PLAN CHECK 001-810-00-00-8891 /~
EACH GAS SYSTEM I TO 4 OUTLETS BOILER/COMPRESSOR 3 15 HP TOTAL PLUMBING 00;-s 1 o-oo-oo-s222
EACH GAS SYSTEM 5 OR MORE Mt.TAL FIREPLACE ELECTRICAL 00 1-1:l 10-00-00-8223 /:,::,
EACH INST AL ALTER. REPAIR WATER PIPE VENT FAN SINGLE DUCT MECHANICAL 001-810-00-00-8224
EACH VACUUM BREAKER MECH EXHAUST HOOD DUCTS MOBILEHOME 001-810-00-00·8225
WA 1E R SOFTNER RELOCATION OF E:A FURNACE-HEATER SOLAR 001 ·8 10·00-00-8226
EACH ROIJF nRAlfJ 1 :"J:=;1[1[, DRYER VENT STRONG MOTION 880-519-92-33 /
TOTi.L MECHANICAL FIRE SPRINi<LERS 001-810-00· 00 · 8227
l[llAl PtUMfllr..C I PUBLIC FACILITIES FEE 320-810-00-00-8 7 40
,5 VO BRIDGE FEE 360-810-00-00-8740
OTY ELECTRICAL PERMIT· ISSUE OTY. MOBILE HOME SETUP PARK-IN-LIEU {AREA '
NEW CONST EA AMP SWT HKR CAR PORT TIF 312-810-00-00-8835
IPH 3 PH AWNING LA COSTA TIF 311-810-00-00-8835
EXIST Bl O G EA AMP SWT BK R GARAGE FMF
I PH lPH LICENSE TAX 001-810-00-00·8162
I REMODEL Al HR PER [IR CU IT /o MFF 880-519-92-57
TEMPPOIE 100 AMPS
OVER ]OU AMPS .
TtMPOCCUPANCY 130 DAYSI
. CREDIT DEPOSIT ~6J;/ >
l!lTAL FltLTRILAI I ., TQT Al I r, 16 TOTAL FEES PAYABLE 11/f
! HAVE C~EFULL rEXAMINED THE COMPLETED ··APPUCATJON ANO PERMIT" AN0,00 HEREBY EJ(piratioh Evtry per_mit it'.'suedbyJhiBuifdlfl provis«:iriSofth11· * AN OSffA Pf.RM.'T IS RE0UIAEO .FOR EXCAVATIONS OYf.R
CERTIFY UNDER PENAL TY. OF PERJURY THAT ALL INFORMATIO~'. HeREQN ~INCLUDING THE ~e shall ttxpir• by ttm.•taiion 1 and 'Void If :rr~:,.oing, O,r wbrll 5' O" DEEP AND OOIOLITION 0A CONSTRUCTION OF
DECLARATIONS ARE TRUE ANO CORAECT AND ' FURTHER CERTlFY ANO AGREE IF A PERMIT I& ~-~ \;" .:::~~ ~~.Jay,~~.~. date <I' "'c~ . / $TAUCTUAES O\«E:A 3 STORtES IN HEtGHl
IssuED• TO COMPLY WITH ALC CITY COUNTY AND STATElAWS GOVEflNING BUILDING CON-•--., ••· .,.. ·· f!'.-000 .o 1 • . .
,SIAUCTIQN WHETHER SPECIFIEO HEREU,LOflNOT. j ALSO AGREE TO SAVE>iNOEMNIA' AND . ' si ' n ✓ :v co~~ ~ I o¾-7 /('; ' KtEP HARMLESS 1"HE clTy OF C1f1L~(!~0 1'QAtN5r Att., ttAeturie,S. JtiQGMEf,tTS:. cosrs 'ANO, ,APPl.LC,.NT,s ~ NAT~ -~ ~).:" ·~ ~r~~ CJ','
_l:.XPENSffiWHtCHMAYlNANYWAY~Cy~:AGAIN~T~IO,CfTV,INCO~~t;{CrOf:"fH~, , "~~ , , , ; ,, 8V~c.'!IN£i)
'GRANTINGQFTHISPJ:RM11· ,,,, ·.,,,' i ';t,,.,,. ,;, , ,· ',, :., .,; · ,,.t,,">,,.,, '+,,,f,'.·,.
~
LL
>-;;;
0
0.
E w ,-.
'2
0
CJ
C m u
0. 0.
<{
I
~
C
a.
0 w ~ w w ~
<{
~ .2
w >-
w u C m
C
LL
~
C w ~
CJ
0 u w a. w
C
)';
" ,:
TYPE ' DATE INSPECTOR
BUILDING C£i 8'1 0 I () &.
FOUNDATION ---< ' /.' " FIELD INSPECTION RECORD
REINFORCED STEEL I " -s/1 /W 1
MASONRY , ,
I
F\EQUIRED SPECIAL INSPECTIONS INSPECTOR'S NOTES ' .
GUNITE OR GROUT ' INSPECTION REQ IF INSPECTORS DATE , CHECKED APPROVAL
SUB FRAME □ FLOOR D CEiii.iNG /)
SHEATHING □ ROOF □ SHEAR ,/, ;'.3 I '3'. i.; /'I', I/ / J
SOILS COMPLIANCE
PRIOR TO
FRAME .: l~-c t/,..:, 17 ,,, FOUNDATION INSP
EXTERIOR LATH I •rh, 1/YJ l"'r'/J STRUCTURAL CONCRETE
OVER 2000 PSI
INSULATION , 1::z/;1,7 '/ i.JI I
INTERIOR LATH & DRYWALL ' I {
PRES TRESSED
CONCRETE
POST TENSIONED
I CONCRETE
PLUMBING I FIELD WELDING
□ SEWER AND BUCO □ PWCO
'UNDERGROUND □ WASTE □•WATER
HIGH STRENGTH
BOL Ts
TOP OUT □ WASTE □ WATER SPECIAL MASONRY
l"UB AND SHOWER PAN '
GAS TEST i
PILES CAISSONS
□ WATER HEATER □ SOLAR WATER
I '
ELECTRICAL -□ ELECTRIC UNDERGROUND DUFFER /)
ROUGH ELECTRIC ' '? /2, 7, ,,.., I ' □ ELECTRIC SERVICE □ TEMPQRARY ' ' □ BONDING □ POOL ' I
MECHANICAL I " . □ DUCT & PLEM., □ REF. PIPING -. .
HEAT -AIR COND. SYSTEMS ' I ' VENTILATING SYSTEMS I
'
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE
ITEM§i_/lB_OVE HA V.E BEEN APPROVED.
FINAL \ I
PLUMBING '\. I
ELECTRICAL \ I /) . . .
MECHANICAL \. I ,! ,, J,,,., T
GAS 1 I "f/1-lf' I .
.
' ' ' ' ,. ' . ,. ,, -
BUILDING : ' .,
SPECIAL CONDITIONS ' '\
'
'
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208 t'G=,'D. (?"f",C....1'--2-I '<-:;-[ 2>".>
SAN DIEGO, CA 92123
(619) 560-1468
JURISDICTION: G:0::YJ--,L,(.•8 1'.:l, :>
PLAN CHECK NO: B~~ ,oz SET: ..J:C FILE COPY
QUPS
QDESIGNER
PROJECT ADDREss :_2-_~~o-""e:,:-.--'M--'--'-'-A-'--'r,.___-A--'--''i\~J_rc.....) _\~::>=(,...=---• _
PROJECT NAME : _____ \2.o __ O_V\_J\ __ \ft~\)-'--L_)· _, ____ _
D
D
0
D
D
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the_jurisdiction's buil}ing codes when minor deficien-
cies identified lo tc1...o<..-i are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check
The plans
plans are
list transmitted herewith is for your information.
are being held at Esgil Corp. until corrected
submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
:ffij Esgil staff did not advise the.applicant contact person thaJ:
plan check has been completed.
O Esgil staff did advise applicant that the plan check has
been completed. Person contacted: ____________ _
Date contacted: _________ Telephone# ________ _
REMARKS : lJ o:tE; o I\ ) 'Pu7Y' ) 11 U) N 11,)8 ,::.,TI p )'.I 2 o r=-
~\2 \.:;:.111;;0 :tr,) 1?1l;(>-t VV) ) \,.;,.) 1t\J.. k':t:?:zS TD
By: .:::r; \N\ G, \....SH-I )9-;1)
ESGIL CORPORATION
Enclosures:.Q~\--'-\1-----'f\--~~J"'-"S'------
. ESGIL CORPORATION
9320 CHESAPEAKE OR., SUITE 208 a-,:~. (!!Git... I /z.c. I~")
SAN DIEGO, CA 0:?l:?3
( 6 l!J) 560· 1-'68
DATE:
JURISDICTION: CITY OF CARLSBAD
PLAN CHECK NO: B~-10'2. SET: I §FILE COPY
UPS
DESIGNER
PROJECT ADDRESS: -240 B.
PROJECT NAME:
□
□
□
□
□
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified-,---.-----,,-----=-,:------are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies-
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp.·until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the
AN.T\-\ c, H':{ g.E I\J,:\))9
check list has been sent to: 'fi O , Go"-. & .3(o
Esgil staff did not advise the applicant contact person that
plan check has been completed, C>-n->t~~ "t"\-!'Q-1--l M "llLllVC,,-·
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted: _______ Telephone t ________ _
REMARKS: --------------------------
BY: 0W] Gll..6\:t'Y3N
ESGIL CORPORATION
PLAIII (]II!(% 110,,_~B,!_~=!._-...l.1 o~Z-------
JOJ1ISD1c:nmr: cm or cu;• DAD
l'O:..JcVtL0~)J1-+ow...,::i:,,,.:I\..J~~l--~e~G=..,N..:..!..:N~'A...!.-__ _
°bo'f-2?3 c, \J, ~IA
Rl!IIARIS: --"'---------------
PLU1 u.WR@ I 11• ?PT
crn or CARI DAD
SDIGIJ! y.um '! UII IIIPL'IX llliBLLillGS
Date plans received by jurisdiction:
I\ '2.5'1 ~9
Date plans received by Esgil Corporation:
\\2.(., I 8 3
Date initial plan check completed:
zj 8).e,lj By:_:;:r...._.,_rl\"'-'------
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present California law mandates that residential
construction comply with Title 24 and the following
model codes:
1985 UBC (eff. 7/31/87)
1985 UPC (eff. 3/30/87)
1987 NEC (eff, 10/28/87)
1985 UHC (eff. 8/28/87)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
'llle circled items listed need clarification,
modification or change. All items have to be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1985 Uniform Building Code, the approval of
the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, note on this list
(or a copy} where each correction item has been
addressed. i.e., plan sheet, specification, etc. Be
sure to enclose the marked up list when you submit
the revised plans.
Applicant contact person:
12.e:N.1::4A Telephone: '34-\ "'14-7 'Z. --___ -----~/
JmZ: P~ mllllRS AIII Im ~-;;-PNZI BAYm; 110 ~ llll!ll;:,,w■;l'G WID ::... ........ J
List No. 63, C&rlsbad Single Family Dwelling and Duplex With All Supplements. (1985 UBC)
(D
t
I
I
I
I
I
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
Esusg
1
_1t·e1 Corporation, 9320 Chesapeake Drive,
#208, San Diego, California 92123,
(619) 560-1468.
ease make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302{a)7.
All sheets of plans must be signed by the
person responsible for their preparation.
(California Business and Professions Code).
Plans, specifications and calculations shall be
signed by the California state licensed
engineer or architect responsible for their
preparation, for plans deviating from
conventional wood frame construction. Specify
expiration date of license. (California
Business and Professions Code).
Specify on the Title Sheet of the plans the
gross floor area of each element of this
project including dwelling, garage, carport,
patio, deck and balcony. Section 302(c).
Provide a statement on the Title Sheet of the
plans that this project shall comply with Title
21+ and 1985 UBC, UMC and UPC and 1987 NEC.
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes. Show finish floor elevations and
show elevations of adjacent finish grade.
Show drainage patterns with minimum slopes.
Section 302(c).
Indicate distance
proposed building.
from property
Section 302(c).
lines to
12/16/87
I
I
:I
Show on the title sheet all structures, pools,
walls, etc. included Wlder this application.
Any portion of the project shown on the site
plan that is not included with the building
permit application filed should be clearly
identified as "not included."
Clearly show if the lower level is a basement
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
the distance. to the floor above, for story
determination.
FIRa PROU.Cllud
Walls closer than 3 feet to property lines
shall be one-hour rated construction, have no
openings, and shall have 30 inch parapets when
the building floor area exceeds 1,000 square
feet on any floor.
(Table 5-A, Section 1709 (a)).
Projections, including eaves, may not extend
more than 12 inches into the 3 foot setback
from the property line. Eaves over required
windows shall be not less than 30 inches from
the side and rear property lines. Section
1710 and Section 501+ (a) and (b).
Plastic skylights shall not
within 81 of an exterior wall
openings in such exterior wall
or required to be protected.
Section 5207 (a) 7.
be installed
located where
are prohibited
Projections, including eaves, shall be one-
hour fire-resistive construction, heavy timber
or of noncombustible material if they project
into the 3' setback area from the property
line. Section 1710.
Show location of permanently wired smoke
detector, centrally located in corridor or
area giving access to sleeping rooms or above
stair if sleeping rooms are on upper level.
Section 1210.
A smoke detector shall be installed in the
basement of dwelling units having a stairway
which opens from the basement into the
dwelling. Such detector shall be coMected to
a sounding device or other detector to provide
an alarm which will be audible in the sleeping
area. Section 1210.
When the valuation of a room addition exceeds
$1,000, or when sleeping rooms are created,
smoke detectors shall be provided at existing
bedrooms per item 16 above.
2
19. Habitable rooms., other than kitchens., shall
contain at least 70 square feet of floor area.
At least one room shall have not less than 120
square feet of floor area.
Section 1207 (b).
20. Window area must be at least 1/10 of the floor
area and a minimum of 10 square feet per
Section 1205 (a). Appears to be deficient in
21. Openable window area in habitable rooms must be
1/20 of the floor area and a minimum of 5
square feet. In bathrooms., laundry rooms and
similar rooms 1/20 of area. is required and
minimum is 1.5 sq. ft. (Section 1205 (a)).
22. At least 1/2 of the CODIDOn wall must be open
and have an opening not less than 25 sq. ft.
nor one tenth of the floor area of the interior
room if light and ventilation is being supplied
from an adjacent room. Section 1205 (a).
23. Required windows shall not open into a roofed
porch unless the ceiling height is at least 7
feet., the longer side is at least 65% open., and
the porch abuts a street., yard or court.
Section 1205 (a).
24. Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms., water closet compartments., laundry
rooms and similax rooms if required openable
windows are not provided. Section 1205 (a).
25. No habitable room, other than a kitchen, shall
be less than 7 1011 in any dimension. Section
1207 (c).
26. Show that ceiling height for habitable rooms is
a minimum of 7'6". Section 1207 (a).
27. Show ceiling height for laundry rooms.,
hallways., corridors., and bathrooms is a minimum
of 7'0". Section 1207 (a).
28. Dimension on the plans the 3011 clear width for
water closet compartments and 2411 clearance in
front of water closet. Section 511 (a).
29. Specify safety glazing for glazing in hazardous
locations such as glass doors., glazing adjacent
to such doors and glazing adjacent to walking
surfaces. Section 5406.
12 16/87
30. Glazing, in the same wall plane as a door,
must be safety glazing if within 12" of the
door and less than 6011 above the walking
surface., unless the glazing is leaded or
faceted glass. Section 5406 (d) 6.
31. Glazing in shower and tub enclosures shall be
tempered., laminated or approved plastic
(including windows within S feet of tub or
shower floor). Section 5406 (d) 5.
32. Sleeping rooms shall have a window or exterior
door for emergency exit. Sill height shall
not exceed 4411 above the floor. lba window
must have an openable area of at least 5.7
square feet with the minimum openable width
2011 and the mini.mum openable height 2411 •
Section 1204.
33. A mezzanine is an intermediate floor and may
not have a floor area exceeding 33 1/ 3 percent
of the total floor area in the room below.
The mezzanine floor must have a clear height
of 7 feet., above and below., and must have the
long side open to the room below except for
posts and protective walls or railings not
exceeding 42" in height. Section 1716.
34. The loft you show does not comply as a
mezzanine floor and is., by Uniform Building
Code definition, a story. Section 1716.
EXITS. SL\ll!WAYS. ARD RAlLIIIGS
35. Floors above the second story shall have not
less than 2 exits. Occupied roofs may have
one exit if such occupied areas are less tha.~
500 square feet and located no higher than
i.olnediately above the second story. Section
3303 (a).
36. Required exit doorways shall be not less than
3611 in width and not less than 61811 in height.,
and shall be capable of opening at least 90
degrees. Section 3304 (e).
37. Provide 3611 high protective railing for
porches., balconies., and open sides of stair
landings. Openings between railing shall be
less than 611 • Section 1711.
38. Show how guardrail connection details are
adequate to support 20 pounds per lineal foot
at a right angle to the top rail. Table 23-B.
3
39. Provide stairway and landing details. Section
3306 (b) & (c).
a. Maxi.mum rise is 711 and mini.mum run is 1111•
When the stairs serves less than 10
occupants, or serves an unoccupied roof,
rise may be 811 maximum and run 911 minimum.
b. Minimum headroom is 61 611 •
c. Minimum width is 3611•
40. All handrails per Section 3306 (j), shall
satisfy the following:
a. Provide handrail for stairways with 4 or,
more risers.
b. Handrail shall be 30" to 3411 above the
nosing of treads.
c. The handgrip portion of handrail shall be
not less than 1 1/411 nor more than 211 in
cross-sectional dimension.
41. Every stairway landing shall have a dimension,
measured in the direction of travel, at least
equal to the stairway width. Such dimension
need not exceed 36 inches. Section 3306 (g), _
3304 (i).
42. A door may open inward at the top step of a
stairway provided the top step is not more than
7 1/2" lower than the floor level. Section
3304 (h).
43. Provide details of winding stairway complying
with Section 3306 (d):
a. Minimum tread is 6 inches at any point and
minimum 9 inches at a point 12 inches from
where the treads are narrowest.
b. Maximum rise is 8 inches.
c:. Minimum width is 36 inches.
44. Provide spiral stairway details, per Section
3306 (f):
a. Mini.mum run is 7 1/2 inches measured at a
point 12 inches from where the treads are
the narrowest.
b. Maximum rise is 9 1/2 inches.
e. Minimum headroom is 6 feet 6 inches
d. The tread must provide a clear walking
area measuring at least 2.6 inches from the
outer edge of the supporting column to the
inner edge of the handrail.
12/16/87
45. Spiral stairways may not be used for required
exits when the area served is greater than 400
sq. ft. Section 3306 (f).
46. Provide I.C.B.O. Research Report and number
for metal stair'trlay., or submit plans and
calculations and approved fabricator
registered with the building department or
note that the stair.,ay fabrication plans shall
be submitted to and approved by the building
official prior to installation.
47. In buildings over 2 stories in height., provide
3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within
10 feet horizontally of an exterior stairway.
An exit balcony with 2 separated stairways is
exempt. Section 3306 (1).
48. Openings in exterior walls below or within 10
feet., measured horizontally., of an exterior
stair shall be protected by self-closing fire
assemblies having a three-fourths-hour fire
protection rating when the stair serves a
floor level having openings in two or more
floors below it. An exit balcony with two
separated stair.-ays is exempt.
Section 3306 (1).
49. Exterior stairways shall not project into the
3 foot setback from the property lines.
Section 3306 (n).
50. The walls and soffits of the enclosed usable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Section 3306
(rn) •
51. Within units., show that corridors have a
minimum width of 36 inches. Section 3305 (b).
52. Specify roof slope.
53. Roof slope is not adequate for roof type
specified. Tabla 32-B; Section 3203 (h).
54. · Specify roof material and application.
Chapter 32.
55. Specify I.C.B.O. or U.L. approval number for
roof materials not covered in U.B.C • ., e.g • .,
tile., etc. Section 107.
56. The maximum slope for a fire retardant built·
up roof, with rock or gravel surfacing, is 3
inches in 12 inches. Section 3203 (e) 2.
57. The minimum slope for a fire retardant built-
up roof, with cap sheet surfacing, is 1/2 inch
in 12 inches. Section 3203 (e) 3.
58. Specify minimum 1/4 inch per foot roof slope
for drainage or design to support accumulated
water. Section 3207 (a), Section 2305 (f) and
Section 2511 (d) 6.
59. Show roof drains and overflows. Section 3207.
60. Provide skylight details to show compliance
with Sections 3401 and 5207 or provide I.C.B.O.'
approval number.
61. Plastic skylights must be separated from each
other by at least 4 feet. Section 5207 (a) 6.
62. Show attic ventilation. Minimum vent area is
1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least 3
feet above eave vents or cornice vents. Show
required area and area provided.
Section 3205 (c).
63. Provide fireplace construction details or note
construction to be per attached fireplace
standard drawing. Chapter 37.
64. Show anchored veneer support and coMections
attached to wood in Seismic Zones 3 and 4,
comply with Section 3006 (d)l and Section 2515
(a). Show ties and #9 wire in horizontal
joints.
65. Show height and construction details of all
masonry walls. Chapter 24.
66. Note that cleanout openings shall be provided
at the bottom of all cells to be grout filled
in accordance with Table 24-G. Cleanouts shall
be sealed before grouting, after inspection.
67. Show floor and roof coMections to masonry
walls. Connection shall resist 200 pounds per
lineal !oot or the actual design load,
whichever is greater. Cross grain tension or
bending in wood ledgers is not permitted.
Section 2310 & 2312 (j)3A.
68. Provide details for damp proofing the
foundation walls, below finish grade, where
usable space exists on the interior side of the
walls. Section 1707 (d).
12/16/87
69. Show a minimum 2" air space and flashing
between planter and building walls.
Section 2516 (c) 7.
GARAGE AIID CARPOR7S
70. Garage requires one-hour fire protection on
the garage side of walls and ceiling co111110n to
the dwelling. Table 5-B, Section 503 (d).
71. All elements supporting floor above garage,
including walls supporting floor joists, must
have one-hour fire-resistive protection on the
garage side. Section 503 {b)
72. Show l 3/8" solid core self-closing door for
openings between garage and dwelling. Section
503 (d).
73. Garages are not permitted to open into a room
used for sleeping purposes. Section 1104.
74. An occupancy separation is not required
between carport and residence, provided the
carport is open on two or more sides and has
no enclosed uses above.
Section 503 (a) Exception 3.
75. Show garage framing sections, size of header
over garage opening, lateral cross bracing at
plate line, method bracing garage front and
holddowns if required. Chapter 23.
NOTE: Maximum shear panel ratio is 3 1/2 to l
for height-to-width. Table 25-I.
76. Doors may open into the garage only if the
floor or landing in the garage is not more
than one inch lower than the door threshold.
Section 3304 (h).
77. Provide an 1811 raised platform for any FAU,
water heater, or other device in the garage
which may generate a flame or spark. UHC
Section 508, UPC Section 1310 (a).
78. Per soils report, note on the plan the soils
classification, whether or not the soil is
expansive and note the allowable bearing
value. Section 2905 (c).
79. The foundation plan does not comply with the
soils report recoDDendations for this project.
Please review the report and modify design,
notes and details as required to show compliance: ______________ _
5
so/ Provide notes on the foundation plan listing 7-the soils report recoamendation for
foundations, slab and building pad preparation.
(
/.
Provide a letter from the soils engineer
confirming that the foundation plan, grading
plan and specifications have been reviewed and
that it has been determined that the
recommendations in the soils report are
properly incorporated into the construction
documents (when required by the soil report).
The soils report recomDendations excavations be
reviewed by soils engineer. Note on the
foundation plan that "Prior to the contractor
requesting a Building DepartJDent foundation
inspection, the soils engineer shall advise the,
building official in writing that:
1. The building pad was prepared in
accordance with the soils report,
2. The utility trenches have been properly
backfilled and compacted, and
3. lhe foundation excavations, formings and
reinforcements comply with the soils
report and approved plan.11
fri. Show height of all foundation walls. Chapter
23.
84. Show height of retained earth on all foundation
walls. Chapter 23.
If cut or fill slopes exist, show distance of
foundation to edge of cut or fill slopes and
show steepness and heights of cuts and fills.
Chapter 29.
Note on plans that wood shall be 6" minimum
above finish grade. Section 2907 (a).
Note on plans that surface water will drain
away from building and show drainage pattern
and key elevations. On graded sites, the top
of any exterior foundation shall extend above
the street gutter at point of discharge or the
inlet to a drainage device a mini.mum of 1211
plus 2 percent. Section 2905 (f), 2907 (d) 5.
88. Dimension foundation per U.B.C. Table 29A:
Floors [ooting
S!:!RJ2:orted* Stemwall Width Depth Thickness
l 6" 1211 1211 6"
2 8" 1511 1811 7"
3 1011 1811 2411 8"
>':Foundations may support a roof in addition to the
floors. Where only a roof is supported, use
foundation for one floor.
S\:!Ql.J( p
12/16/87
i
f·
r·
Show foundation sills to be pressure treated,
or equal. Section 2516 (c) 3.
Show foundation bolt size and spacing.
Section 2907 (f).
Specify size, I.C.B.O. number and manufacturer
of power driven pins. Show edge and end
distances and spacing.
Section 302 (c).
If required by structural calculations, show
size, imbedment and location of hold down
anchors on foundation plan. Section 2312 (f),
302 (c).
If hold downs are required by calculations,
note on plan that hold down anchors must be
tied in place prior to foundation inspection.
Section 305 (e) l.
Show adequate footings under all bearing walls
and shear walls. Section 2907 (b).
Show on the plans stepped footings for slopes
steeper than 1:10. Section 2907 (c).
Show minimum 1811 clearance from grade to
bottom of floor joists and minimum 12"
clearance to bottom of girders.
Section 2516 (c) 2.
Show pier size, spacing and depth into
undisturbed soil. Table 29-A.
Show minimum underfloor access of 1811 x 2411 •
Section 2516 (c).
Show oinimum underfloor ventilation equal to 1
sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners
as practicable and shall provide cross
ventilation on at least two approximately
opposite sides. Section 2516 (c) 6.
Specify that posts embedded in concrete shall
be pressure treated per UBC Std. No. 25-12.
Section 2516 (c) 1.
FRAMDIG
Show wall bracing. Every exterior wood stud
wall and main cross partition shall be braced
at each end at least every 25 feet of length
with 1 x 4 diagonal let-in braces or
equivalent. Section 2517 (g) 3.
Note cross bridging or blocking. Floor joists
and rafters 1211 or more in depth shall be
supported laterally by bridging at intervals
not exceeding 8 feet, unless both edges are
held inline. Sec. 2506 (h), 2517 (a) 6.
6
10/ Sho~ blocking at ends and at supports of floor 7~ joists, rafters and trusses at exterior walls.
/ Section 2517 (d) 3, 2517 (h) 6.
1p4. Show double joists. Floor joists shall be
doubled under bearing partitions running
parallel with the joists. Section 2517 (d) 5.
Bearing partitions, perpendicular to joists,
shall not be offset from supporting girders,
beams, walls or partitions, more than the depth
of the joist. Section 2517 (d) 5.
Show rafter ties. Rafter ties shall be spaced
not more than 4 feet on center and be just
above the ceiling joists, where rafters and
ceiling joists are not parallel. Section 2517,
(h) 4.
Show rafter purlin braces to be not less than
45 degrees to the horizontal.
Section 2517 (h) 5.
Show l/2" minimum clearance between top plate
of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
Show double top plate with minimum 4811 lap
splice. Section 2517 (g) 2.
Show nailing will be in compliance with Table
25-Q.
,/11. Show or note fire stops at the following
locations per Section 2516 (f):
a. In concealed spaces of stud walls and
partitions, including furred spaces, at
the ceiling and floor levels and at 10
foot intervals along the length of the
wall;
b. at all interconnections between concealed
vertical and horizontal spaces such as
occur at soffits, drop ceilings and cove
ceilings;
c. In concealed spaces between stair
stringers at the top and bottom of the run
and between studs along and inline with
the run of stairs if the walls under the
stairs are unfinished; and
d. in openings arowid vents, pipes, ducts,
chimneys, fireplaces and similar openings
which afford a passage for fire at ceiling
and floor levels, with noncombustible
materials.
12 16/87
Show stud size and -~ allowable
stud heights: Bear~ 2~:;'"'and 2 x 6
max. 10'; Non-bearing: 2 x 4 max. 14', 2 x 6 max. 20 1 • Table 25-R-3.
Studs supporting two floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 16" o.c.
Table 25-R-3.
Note on A.I.T.C. Certificate of Compliance for
glued laminated wood members shall be given to
the building inspector prior to installation.
Section 306 (f).
7 @. Detail all post-to-beam and post-to-footing
/
connections and reference the detail to the
1 plan. Section 2516 (m).
1/ Detail shear transfer connections, including
roof and floor diaphragms, to shear walls.
Section 2513.
ii/. Specify nail size and spacing for all shear
/ walls, floor and roof diaphragms. Indicate
required blocking. Maintain maxi.mum diaphragm
dimension ratios. [Tables 25 I, J, Kand
Section 4713 (d)].
r ( Show 311 x 4" or 211 x 6" studs in first story '/°" of three story building. Table 25-R-3.
11/. Provide truss details and truss calculations 7 · for this project. Specify truss
identification numbers on the plans.
, I'S£. ~,~Tl V 4-• Provide roof framing plan A""~ 1'1-,,...t'r~
plan-: Section 302 (c).
121. Provide framing sections through
""fl:tl4i.J :t-H t:; ex,~,--, l'l.)c,. e, , iZM•
fi:!YQ f-'r-Oo,ncv e;-s~'""-' ++ow
~ W) '\3 c.);S l..l ~ LD>'l-0 ( ljqv s.~
(o ~ ~ "flnaOgSI '0~01G-i:\eU~ \S(\)i) 7,~
Section 302 (c).
1-d. Specify all header sizes for opening over 41 r wide. Section 2517 (g) 5.
r-
Provide calculations for main vertical and
horizontal framing members and post footings.
Section 302 (b).
Provide calculations for lateral loads, shear
panels, shear transfer and related. Section
302 (b).
\'<.uf>.J)
7
Show on the plans all structural requirements
developed in the structural calculations.
Section 302 (c). (See co11111ents below or at
end.)
Columns and posts located on concrete or
masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be supported
by concrete piers or metal pedestals projecting
above floors unless approved wood of natural
resistance to decay or treated wood is used.
Section 2516 (c) 4.
1,,/ Individual concrete or masonry piers shall 7 · project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood ofi natural resistance to ·
decay or treated wood is used.
Section 2516 (c) 4.
12/ Show location of attic access with minimum size
2211 x 3011 • Section 3205.
~
Show draft separation for attic areas between
units in a duplex. Section 2516 (f).
Specify plywood grade and panel identification
index. Table 25-N.
When roof pitch is less than 3:12,·design ridge
as a beam, Section 2517 (h).
If foundation cripple wall studs are less than
14" high, framing shall be solid blocking.
Section 2517 (g) 4.
Cripple wall studs exceeding 4 feet in height
shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 2 stories.
Section 2517 (g) 4.
Show plywood sheathing over
other weather exposed areas,
Section 2516 (i).
exposed eaves, or
is exterior grade.
13.( Show a weep screed at the foundation plate line 7· on all exterior stud walls to be stuccoed.
Section 4706 (e).
l~. Detail truss layout for 30" x 30" attic access,
if required for equipment in the attic.
1~.
Ridges, hips, and valleys shall be at least one
size larger than supported rafters. Section
2517 (h) 3.
In open beam construction, provide strap ties
across the beams at the ridge support. Section
2501 (b).
12/16 87
HECIAIIICAL (llllll'ORK KECIIAIIICAL CODE}
All heating, ventilating, and cooling systems and
appliances shall comply with the Unifom Mechanical
Code.
i,15.
;.6.
f·
Show the size, location and type of all
heating and cooling appliances or systems.
Show source of combustion air to furnace, per
Chapter 6, UHC.
Every dwelling unit shall be provided with
heating facilities capable of maintaining a
room temperature of 70 degrees F. at 3 feet
abcve the floor in all habitable rooms. Show
basis for compliance. UBC, Sec. 1211.
Show minimum 30" deep unobstructed working
space in front of furnace. Section 505, UMC.
Note on plans, "clearances to be per
manufacturer's listing." Section 504, UMC.
Furnace shall not be installed in any bedroom,
bathroom or in a closet or confined space with
access only through such room unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 704 UHC.
Show I.C.B.O. approval number for prefab
fireplace.
Show access to the attic or underfloor furnace
to be minimum 30 inches by 30 inches.
Section 708 & 709 UHC.
Note that passageway to the attic furnace
shall be wiobstructed and have continuous
solid flooring not less than 24 inches wide.
Section 708 UHC.
Show permanent electrical outlet and lighting
fixture controlled by a switch for the attic
furnace. Section 708 UHC.
Show details to comply with Section 709 for
furnace under the floor, or Section 710 for
roof or outside furnace.
Note on plan: Gas vents and non-combustible
piping, in walls, passing through three floors
or less shall be effectively draft stopped at
each floor or ceilins.
UBC, Section 1706 (a) 6.
Provide dryer vent to outside. UMC, Section
1903.
8
V "'<PlJCAL fJIIArl<lW: !I !"c"IJCAL <Xml
All wiring shall comply with the National Electrical
Code.
152. Show on the plan the amperage of the electrical
service, the location of the service panel and
the location of any sub-panels.
153. Show location of all electrical receptacles.
154. Electrical receptacle locations and/or spacing is not adequate inc_ ___________ _
155. Show at least one convenience outlet other than
outlets for laundry, etc., outdoors, in garages
and basements. NEC, Art. 210·52.
156. Note convenience outlets in bathrooms, kitchen
counter top(s) within 6 feet of the kitchen
sink, outdoors, and in garages and basements
(other than for laundry and similar equipment)
shall be GFI protected. NEC, Art. 210·8.
157. Note electrical system ground to be provided
per NEC, Art. 250-81.
PLIIIBIIIG {UNlltidt rLIIIBDIG ODDI!)
158. Show water heater size, type and location on
plans. UPC, Section 1301.
159. Show source for providing combustion air to
fuel burning water heater. If wall openings in
an enclmmre are used, Rt least one-half of the
required opening area shall extend into the
upper twelve inches of the enclosure and one-
half within the lower twelve inches. UPC,
Section 1307.
160. Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom. UPC, Section
1309.
161. Provide adequate barrier to protect water
heater from vehicle damage. UPC, Section 1310.
162. Show T and P valve on water heater and show
route of discharge line to exterior.
UPC, Section 1007 (e).
163. Note on the plan that hose bibbs and lawn
sprinkler system shall have approved backflow
prevention devices. UPC, Section 1003(h) &
(i).
7 29 88
164. Show shower stall can accomodate a 30" circle
and has a minimum floor area of 1,024 sq. in.
UPC 909 (d).
Jl'.IISI! IIISUIAr.UXf {lm'LIX!S)
165. Show details of duplex common (party) walls
and floor/ceiling assemblies to achieve a
Sound Transmission Class (STC) rating in walls
of 50 decibels and an Impact Insulation Class
(IIC) rating on floor/ceiling of 50 decibels.
Title 25.
166. Show how penetrations of assemblies for
piping, electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 25.
167. Provide insulation in walls and ceiling to
achieve STC of 50 between garage and 1i ving
area if garage use is not controlled by
resident. Title 25.
IIIIRGf wilSiimu.IIII
168. Permit applications received after June 30,
1988, are regulated by the new Residential
Energy Standards. Provide plans, calculations
and worksheets to show compliance.
169. The new regulations require a properly
completed and properly signed Form CF-lR to be
either imprinted on the plans, taped to the
plans or "sticky backed" on the plans, to
allow the building inspector to readily
compare the actual constnJc.tion with the
requirements of the approved energy design.
170. Section 1403(a)l, Title 24, states that Form
CF·lR shall be signed by the person
responsible for its preparation. lhe signer
shall be a civil engineer, mechanical
engineer, electrical engineer, architect,
general building contractor, mechanical
contractor or electrical contractor licensed
or registered to practice by the State of
California or other individual eligible under
Division 3 of the Business and Professions
Code to sign such documents. Document signers
are subject to the limitations in Division 3
of the Business and Professions Code. Please
provide the signature.
9
X
· 11/.' All energy items shown on the plans rust be in
agreement with the information shown on the
properly completed Form CF-lR.
Specify on the building plans all of the
mandatory energy conservation requirements as
listed on the enclosure titled, ''Mandatory
Energy Conservation Reouirements11•
Show the make, model and efficiency of the
space heating ( or cooling) system and provide
heat loss calculations if the output exceeds
45,000 BTU/Hr.
r/.. For room additions, show that the glazing area
{ of the addition does not exceed 16% of the
newly-conditioned floor area, plus glazing
removed or relocated due to the addition. ' f · See additional corrections below or at end.
!W'[SBAD ",F .p. & Dlll'UX SIJPPLDlllll
1.J. Energy conservation design should be for Zone T 1 • See attached energy packages.
17/. Floor drains must have auto-prime (city r: policy).
11. Note exhaust fans cannot be ductless type (city r· policy). . lt• New residential units must be pre-plumbed for
future solar water heating. Note "two roof
jacks must be installed" where the water heater
is in the one story garage and directly below
the most south facing roof (City Ordinance No.
8093).
Note 11two 3/411 copper pipes must be installed
to the most convenient future solar panel
location when t.he water heater is not in a one
story garage and is not directly below the most
south facing roof. {City Ordinance No. 8093).
All piping for present or future solar water
heating must be insulated when in areas that
are not heated or cooled by mechanical means
(city policy).
@ 0'-z..o01 o e 'Oi.am-t 1-o i:=-
~\~TI 1\JG.
1 °/. Incorporate the waterproofing details, on the
/
0
attached Policy 80-8, "'1era interior living
space occurs below grade at the masonry
wall(s).
Show on the title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 112383. r, All new residential buildings, including
additions, require a soils report. Please
submit two copies.
18{. Heavy timber framing, mini.Dam 6" x 10" beams
and minimum 811 x 8" post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptAble if shown on the plans. (city
policy).
IJBC Adopting Ordinance 8792 requires Fire
Retardant roof on all structures (Sec.
18.04.230). Show compliance with IJBC Section
3203(e).
City Ordinance 9792 requires two parking
spaces/unit with clear area of 20'x20' i.e. no
washing machines, etc. Show compliance.
Please see additional corrections, or remarks,
on the following page.
City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, talifornia 92123; telephone number
of 619/560-1468, to perform the plan check for your
project. If you have any questions regarding these
plan check items, please contact~-------
at Esgil Corporation. If you have any questions
regarding City Building permit procedures, please
contact Carter Darnell at the City of Carlsbad,
1200 Elm Avenue, telephone 619/438-1161.
Ihank you.
Enclosures:
2.
3.
~ CL-R-Q\P'-{ l(olJ\2. '' GoYl)C\'213\ ~ \0 "io6 \O~ ?ouQ.e:C> 0Vi3'2-.
~\ -6(\ 11.)vr :SLe:e m 1 v, 12. 11 -n+1c..\:.. •1 "':' '40\) t'\.)l::'\,,.,-J ~
/29 88 10
(I~ ?l2.0J1 Qe '2 Go 1'1 e:S C. F ~O I I..<;. ~ Sl=',)n,.,-o R. DOT'S O tl I"-, l'\-1\) "4 >J~
8l1'--!:> Y(2.o1¢U:::MS 4-">" K>Ul\)O)Or-i,otJ 11VStei:.:norJ S\+-A,-u., 1013:
t> If ~lc"5.0l-Ue0 B'-( ~ :Soll...!!. ,sr,.X ... ,11.)~ -
'IIIK FOLLOlffi;C 110IES Sl'ECD'YlllG 1W1DAICRY ~ SIICULD BX I!IC:OIU'O.'!AllJJ 011 PL\11 SIIEtIS, OR
C:ONTAI!!!D vrmilf JOB Sl'ECI7ICA:II01f OOCIMl!llIS.
(l) All heating, ventilating, air conditioning, and water heating equipment shall meet all of the
requirements of the Appliance Efficiency Standards and shall be certified by the California Energy
Comission.
(2) A two stage themost.at, which controls the supplementary heat on its second st.ago, shall be
provided for heat pumps. ·
(3) Thermostats shall be equipped with an automatic setback, which the building occupant can program to
automatically set back tha thermo st.at twice in 24 hours.
(") Equipment which requires preventive maintenance to maintain efficient operation shall be furnished
with complete necessary maintenance information.
(5) All gas·fired fan type central furnaces, gas•fired fan type ,..all furnaces, and cooking appliances
shall be equipped with an intermittent ignition device.
(6) All fan systems exhausting air to the outside shall be provided with backdrafe dampers.
(7) All transverse duce, plenum, and fieeing Joines shall be sealed with pressure sensi1:ivo tape or
mastic to prevent air loss and shall be insulated ea conform ea the provisions of Secdon 1005 of
the \IMC, 1982 Edition.
(a) A vapor barrier is required in climate zone l, l", and 16.
(9) All manufactured windows and sliding glass doors shall meee the 1972 ANSI air infiltration
standards and shall be certified and labeled.
(10) All swinging doors and windows leading eo unconditioned areas shall be fully weather-stripped.
(ll) Storage type water heaters and storage and backup tanks for solar systems shall be externally
w-rapped ,d.t.'l R-12 i."..sulation or greater.
(12) lhe five feet of pipe closese to the water heater, if outside conditioned space, shall be insulated
with a miniJmJm of R·3. Steam and steam condensation return piping and recirculating hot water
piping outside the building envelope shall be insulated in accordai,ce with T20·l..06(d).
(13) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficiency of
not less than 25 lumens per watt. ·
(l") Showerheads and faucets shall be equipped with flow restrictors as outlined in th• appliance
efficiency standards and shall be certified to the Energy Commission. .
(lS) Masonry and factory-built fireplaces on exterior walls, shall be equipped with tight-fitting
closeable metal or glass doors covering the entire opening of the firebox; a combustion air intalta
equipped vith a readily accessible, operable, and tight fiteing damper to draw air from the outside
of tho building; and a tight fitting flue damper with a readily accessible control.
(16) Insulation used shall comply with California Quality Standards.
(17) The insulation installer shall post. a signed certificate •.• Section.276.. Insulation Certificate
(All Occupancies). After installing insulation, the installa.r shall pest. in a conspicuous locar.ion
in the building a certificate signed by the installer and the builder st.a.ting that the installation
conforms the requirements of '?itla 24, Part 2, Chapter 2-53, and that the materials installed
conform with the requirements of Title 20, Chapter 2, Subchapter r.., Article 3. Dia certificate
shall state the manufacturer's name and material identification, tha installed "R" value, and (in
applications of loose fill insulation) tha minimum installed weight per square foot consistent with
t.ha manufacturer's labeled density for tha desired "R" value.
(18) For infiltration control all openings and penetrations must be caulked and sealed, such as around
windows, at sola plates, and openings for utility pipes and wires.
Form EC! 3/5/86
Prepared by, wM
CITY OP CARLSBAD
VALUATION AND PLAN CHECK FEE
a Bldg. Dept,
a Esgil
PLAN CHECK NO, 85:> -IO '2. CT>
BUILDING ADDRESS 2.4ft, fY})9::rf\'11,JQ ~
APPLICANT/CONTACT W\ \'2.:\C.l: N 1-J A-PHONE NO•-----.---
BUILDING OCCUPANCY \G-"5 (A-DO.) DESIGNER PHONE ____ _
TYPE OF CONSTRUCTION V-N ' CONTRACTOR PHONE ____ _
31.IILDING PORTION BUILDING AREA VALUATION VALUE
MULTIPLIER
-
L \ L) I IV I-..-1 Oh •.~l.P,oo ::: '11 ~B ,
I
Air Conditionin~
Commercial (a
Residential a
Res. or Comm.
Fire Stirinklers @
Total Value 712.B I
Building Per •it roe S ____ 9_'J_._0_0 ___ ---a.------L--------
Plan Check ree-!S'--___ G::.:....L\...;__;_' _~_':::>_-_________ ~$ ______ _
CD" II EN rs._ _________________________ _
Plans received by Esgil after July 31, 1987 shall have permit and
plan check fees calculated per 1985 UBC.
SHEET ___ OF __ _ 12/87
'
!
'" Q
Ill
"O QI
ii:
.!!! > QI 0::
Ill
"O QI ii: QI ·;;
QI 0::
□□
!
'" Q
Ill
"O QI
ii: QI ·;;
QI 0::
D
~□□
c:r-□ □
~□
@ □□
~□□
B-□ □
B □ □
(3 □ □
ca □ □
□□□ ~□□
ITO D
ENGINEERING CHECKLIST
Date: 2.-&-8<=\
Plan Check No. 8°1 6 t O 'Z...
Project Address: 2468 OJA::ff\NO
Project Name: __________ _
Field Check Date: .;;;..;;;.;;..;;..:._ _______ _
B :
LEGAL REQUIREMENTS
Site Plan
LEGEND
7
@
1, 2, 3
Item Complete
Item Incomplete -Ne~ds
Your Action
Number in circle
indicates plancheck
number that deficiency
was identified
2. Show on Site Plan:
rade ad·acent to
elevations, ..
and propose
patterns.
percent
3. Provide legal description of property.
4. Provide assessor's parcel number.
PERMITS REQUIRED
Grading
e
5 .. Grading permit required. (Separate submittal to Engineering
Department required for Grading Permit).
6. Grading plans in plan check PE ____ _
7. Need the following completed prior to building permit issuance:
A. Grading plans signed.
B. Grading permit issued.
C. Grading completed.
D. Certification letter and compaction reports submitted.
E. Grading inspected and permit signed off by City Inspector.
8. Right-of-Way Permit required for work in public right-of-way
(e.g., driveway approach, sidewalk, connection to water main,
etc).
9. Industrial Waste Permit application required. To be filled out
completely and returned to Development Processing.
130 □
0 □ D
0 0 □
□ □ □
El □ □
[j □ □
13 □ □
FEES REQUIRED
10. Park-in-Lieu fees required. --a-Quadrant: Fee Per Unit: , Total Fee: ,
11. Traffic impact fee required.
Fee Per Unit: , Total Fee: -6
12. Bridge and Thoroughfare fee required.
Fee Per Unit: , Total Fee: E3
13. Public facilities fee required. J///f
§ 111. Facilities management fee required. Fee:
15. Additional EDU's required: b)
Sewer connection fee: Sewer permit no.
16. Sewer lateral required: -8-
REMARKS:
Date: -Z. 8-&
If you have any questions about any of the above items identified on this plan
check, please call the Development Processing Department at 1138-1161.
! ! ! .. .. .. C C C
Ill Ill Ill
"O "O "O GI GI GI iS iS iS GI .!! Ill ·s: > ·s:
GI GI GI c,:: c,:: c,::
-N ... ... ... ...
u u u a. a. a.
cf□□
□□□
PLANNING CHECKLIST
Plan Check No. 8Cfo102 Address -<1'QB /11,q;r Al\l o R.
Type of Project and Use Ropmo"'
Zone k'-1 Use Allowed? YEsl NO
Setback: Front __Qh_ Side OK Rear...Q./5.__
Facilities Management Zone lL
School District: San Dieguito _k.,.
Carlsbad
Discretionary Action Required
Environmental Required
Landscape Plan Required
Comments
YES
YES
YES
Encinitas _J{__
San Marcos
NO}){._
NO K
NOA
Type __
----------------------------
Coastal Permit Required YES
Additional Comments -----------------------
OKTOISS~-<--=-DATE_2...,,_,4_?-,,../2-=~-+f---