Loading...
HomeMy WebLinkAbout2411 GRANADA WAY; ; CB120202; Permit• City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02-14-2012 Retaining Wall Permit Permit No: cs120202 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: 2411 GRANADA WY CBAD RETAIN Lot#: 0 1673823300 $10,346.00 Construction Type: NEW Status: Applied: Entered By: Reference #: Plan Approved: Project Title: MILLER RESIDENCE 540 SF RETAINING WALL//SD COUNTY STANDARDS C-8 Area: Applicant: JIM PLEDGER 2550 GOLDLAKE RD LEMON GROVE CA 91945 619-589-1245 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Strong Motion Fee Green Bldg Standards (SB1473) Fee Renewal Fee Add'I Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES Owner: MILLER BARBARA PO BOX 2621 CARLSBAD CA 92018 Issued: Plan Check#: ISSUED 02/02/2012 JMA 02/14/2012 02/14/2012 $136.67 $0.00 $95.67 $0.00 $1.03 $1.00 $0.00 $0.00 $0.00 $0.00 $234.37 Inspect Total Fees: $234.37 Total Payments To Date: $234.37 Balance Due: $0.00 Inspector: Clearance: NOTICE: Please take NOTICE at approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." ou have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any f X i n f whi h I N Tl I rmi h h t City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02-14-2012 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW120040 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: Applicant: JIM PLEDGER 2550 GOLDLAKE RD LEMON GROVE CA 91945 619-589-1245 Emergency Contact: JIM PLEDGER 619-876-2741 2411 GRANADA WY CBAD SWPPP 1673823300 CB120202 MILLER RESIDENCE: 540 SF RETAINING WALL SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES Lot#: 0 Owner: MILLER BARBARA PO BOX 2621 CARLSBAD CA 92018 Status: Applied: Entered By: Issued: Inspect Area: Tier: ISSUED 02/02/2012 JMA 02/14/2012 $50.00 $210.00 $0.00 $260.00 Priority: Total Fees: $260.00 Total Payments To Date: $260.00 Balance Due: $0.00 FINAL APPROVAL DATE Gfa~/ZeLEARANC,JY---- SIGNATURE_-S-.-JC.~~--- M •'~~ "'' "'•/ ~ CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Garlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax: 760-602-8558 www.carlsbadca.gov Plan Check No. C0 202... Est. Value Plan Ck. Deposit Date 0 JOB ADORES~ Lo/ I/ .6--,ifi:,A t.J A--() J1 SUITE#/SPACE#/UNIT# CT/PROJECT# LOT# PHASE# # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE CCC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) .-1+. ~~Tfo-1.>IJ.'JL.r 1<..14L.L... -~VU.trr• l,L-PG"'i EXISTING USE GARAGE (SF} PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS YES •#_ NO • YES • NO • YES • NO • APPLICANT NAME (Secondary Contact) ADDRESS '1 J1:, 1 !;; CITY STATE ZIP PHON C.eL-l. FAX JO~ 'd,. ,;;;-D 5:° t'\-'in'-· ~'fl EMAIL tntL.L.l!i CONTRACTOR BUS. NAME ADDRESS CITY s ZIP /D PHONE FAX MAIL c..orn A LI . # LI .# LA U. LI .# (Sec. 7031.5 Business and Professions Code: Any City or County which·requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's license Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exem};!t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)). " WORKl!RI' COII/IPl!NSA'HON Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following d~glaratttiiis: 0 I have and will maintain a certificate of consent to self-insure for workers' corn_p.ensatiOn as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and wlll maintain workers' compensation, as required by Section-3100 of the labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy ,,,c,· ____ _,. number are: Insurance Co. / Policy No. ---Expiration Date __________ _ ,,,..-]}!s §P<>n need not be completed if the permit is for one red dollars ($100) or less. llt""""Certlflcate of Exemption: I certify that in the p mance of the work for which this permit is · ti~-shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California. WARNING: Failure to secure w rs' compensation coverage is uni , nd shall subject an employer to criminal penalties and clvll fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, d as provided for. of the Labor code, interest and attorney's fees. ~ CONTRACTORSIGNATURE '--" !iii ~NT I hereby affirm that I am exempt from Contractor's License Law for the following reason: • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). • I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). ~ I am exempt under Section _____ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement • Yes • No ~have I have not) signed an applicaton for a build,!,_ng permit for the proposed work. ()r __ • _ L.1't: J 4"1 ~ 1--( ~ave contracted with the following person (fim,) to provide the proposed construction (include name address I phone I contractors' license number): J1 .,_ I ~ 7" 4. I pl provide portions of the wo but I v hired e fo wing person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): ha tr ct the following persons to provide the wort indicated (include name/ address I phone/ type of work): DATE u. 2., { 7..D{']_ Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? • Yes • No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? • Yes • No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? • Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above infonnation Is ool1'8Ct and that the infonnation on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby aulhorize representative of ~e Cly of Carlsbad to enter upon ~e above menooned property for r,spection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABILrTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMn-. OSHA: AA OSHA permit is required for excavations over 5'0' deep and demclition or construCOOn of slrucb.Jres over 3 stories 11 height. EXPIRATION: Every permit issued by the Building Official under the provisk>ns of this Code shall expire by limitation and become null and void if the building or'Mlrk authorized by sucii pennlt is not commenced within 11)(1 days BOO\ the dale of such pennit or if the building or work authorized by such pem1it is suspended er abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ~-,-P., DATE J, ~ • ~/ 2,_ APPLICANT'S SIGNATURE City of Carlsbad Bldg Inspection Request For: 05/22/2012 Permit# CB120202 Inspector Assignment: PY --- Tille: MILLER RESIDENCE Description: 540 SF RETAINING WALU/SD COUNTY STANDARDS C-8 Type: RETAIN Sub Type: Job Address: 2411 GRANADA WY Suite: Location: APPLICANT JIM PLEDGER Owner: MILLER BARBARA Remarks: . Total Time: CD Description 69 Final Masonry Lot: 0 Comments/Notices/Holds Phone: 6195891245 Inspector: ---- Requested By: JIM PLEDGER Entered By: CHRISTINE Associated PCRs/CVs/SWPPPs Original PC# CV990211 CLOSED SW120040 ISSUED JUNK & INOP VEHICLE: MILLER RESIDENCE:: 540 SF RETAINING WALL lns~ection Histo[Y Date Description Act lnsp Comments 02/24/2012 12 Steel/Bond Beam AP PD GROUT 2ND LIFT 02/21/2012 62 Steel/Bond Beam WC PY 02/21/2012 63 Walls WC PY 02/21/2012 66 Grout PA PY 1ST LIFT 02/16/2012 61 Footing AP PY 2<-\ll /Z... z_.o-z__ ~N Cl IRl:"Tl,\N WHUUR f"'\;f,INf LR IN<; CO~IPRESSl\'E STRENGTll TEST l);\T.\ Job Name: Jun PlcJ~cr Job Address: l-H I Gr.in:i.Ja Wa~• Contractor: Subcontractor: Test Location: Req. Strength: Date Sampled: 2-29-12 Date Received: 3--1--12 Sampled by: Tom WOW:. Tested by: NS Sample Type: Grout Sample# Date Tested Age (days) 4924 3-7-12 7 4925 3-28-12 28 4926 3--2R-12 28 CWE#: Permit#: Architect Engineer. Supplier: Mix#; Admixture(s): Truck#: Mix Temp: Slump: Min in Mixer: Area (sq. inches) 9.17 9.28 9.31 2110()27 Maximum Load (lbs) 20,030 31,320 29,990 Plan File#: • Ticket#: Air Temp: ''lo Air: Unit Wt: Comp. Strength Failure Type (psi) 2,180 3,380 3,220 Sampling 1nlormatlon was provided by others. The sample curing from the time of receipl, and compressive strength testing were performed by Christian Wheeler Engineering ln accordance with the applieabte ASTM standards. No other warranties 8J!P(ess or implied. Distribution: Tom Woods padficinsp@yahoo.com Michael B. Wheeler, ACE #45358 ') ~ 1 (I 1i • !, 1 •.I ",_-;II I -. '! i) • /· \ .\ 11 \ 'J ') i (i . !! I