Loading...
HomeMy WebLinkAbout2414 BYRON PL; ; CB130904; Permit05-07-2013 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad.CA 92008 Residential Permit Permit No CB130904 Building Inspection Request Line (760) 602-2725 2414 BYRON PL CBAD RESDNTL Sub Type RAD Status ISSUED 2121433100 Lot* 0 Applied 04/05/2013 $13,700 00 Constuction Type 5B Entered By JMA Reference* PlanApproved 05/07/2013 0 Structure Type Issued 05/07/2013 0 Bathrooms 0 Inspect Area Ong PC # Plan Check* MILES RESIDENCE 104 SF ADDITION TO 1ST FLOOR Applicant HOENIG SETH Owner MILES BRANDON K&JESSICA J PO 1958 CARLSBAD CA 9201 f 760-434-9668 2414 BYRON PL CARLSBAD CA 92008 Building Permit $166 07 Meter Size Add'l Building Permit Fee $0 00 Add'l Reel Water Con Fee $0 00 Plan Check $11625 Meter Fee $0 00 Add'l Plan Check Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $1 37 PFF (3105540) $0 00 Park in Lieu Fee $0 00 PFF (4305540) $0 00 Park Fee $0 00 License Tax (3104193) $0 00 LFM Fee $0 00 License Tax (4304193) $0 00 Bndge Fee $0 00 Traffic Impact Fee (3105541) $0 00 Other Bndge Fee $0 00 Traffic Impact Fee (4305541) $0 00 BTD #2 Fee $0 00 Sidewalk Fee $0 00 BTD *3 Fee $0 00 PLUMBING TOTAL $0 00 Renewal Fee $0 00 ELECTRICAL TOTAL $41 00 Add'l Renewal Fee $0 00 MECHANICAL TOTAL $0 00 Other Building Fee $0 00 Housing Impact Fee $0 00 HMP Fee $0 00 Housing InLieu Fee $0 00 Pot Water Con Fee $0 00 Housing Credit Fee $0 00 Meter Size Master Drainage Fee $0 00 Add'l Pot Water Con Fee $0 00 Sewer Fee $0 00 Red Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SB1473) Fee $1 00 Fire Spnnkler Fees $0 00 Green Bldg Stands Plan Chk Fee $0 00 TOTAL PERMIT FEES $325 69 Total Fees $325 69 Total Payments to Date $325 69 Balance Due: $0 00 Inspector FINAL APPROVAL Date •7AVfo/3 Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenA/ise expired 05-07-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No SWI 30133 Job Address Permit Type Parcel No Reference # CB# Project Title 2414 BYRON PL CBAD SWPPP 2121433100 Lot* CBI30904 MILES RESIDENCE 104 SF ADDITION TO 1ST FLOOR Status Applied Entered By Issued Inspect Area Tier ISSUED 04/05/2013 JMA 05/07/2013 1 Pnority Applicant HOENIG SETH Owner MILES BRANDON K&JESSICA J PO 1958 CARLSBAD CA 92018 760-434-9668 2414 BYRON PL CARLSBAD CA 92008 Emergency Contact SETH HOENIG 760-518-9668 SWPPP Plan Check SWPPP Inspections Additional Fees $47 00 $56 00 $0 00 TOTAL PERMIT FEES $103 00 Total Fees $103 00 Total Payments To Date $103 00 Balance Due $0 00 FINAL APPROVAL DATE CLEARANC SIGNATURE THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMfT ISSUANCE • PLANNING • ENGINEERING IBUILDINC DFIRE • HEALTH • HAZMAT/APCD 4 1^ ^ CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email buildlng@carlsbadca.gov www carlsbadca gov Plan Check No. Est. Value Plan Ck. Deposit Date MM. SWPP JOB ADDRESS l^^-W/M l^yn^ I LOT # ' » I PHASE # I # OF UNITS SUITE#/SPACE#/UN1T# MJ^ -IHS -31 -oo CT/PROJECT# PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TYPE OCC GROUP DESCRIPTION OF WORK /nc/ude Square Feet of/UfectedArea(s; . \ ^ , « [ f. i EXISTING USE I . PROPOSED USE t GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESD # AIR CONDITIONING YES • NO^ FIRE SPRINKLERS YES • No;^ LPpyq^n^|A^ (Primary ^imtact) APPLICANT NAME (Secondary Contact) ADDRESS STATE C<3». . CITY STATE PHONE _ , r ™ . ^ H\ko PHONE EMAIL r EMAIL PROP^TY OWNER VAME INAME r -f- c-c^^ M - / <r CONTRACTOR BUS rOR BUS /HAME I / . ADDRESS 6.S Pi ADDRESS STATE ZIP CITY STATE ZIP PHONE ^ I FAX , 7 . >, i EMAIL AfiCH/OESISNlEFi NAME & ADDRESS STATE LIC« CLASS CITY BUS L1C# (Sec 7031 5 Business and Professions Code Any City or County wtiicti requires a permit to construct alter, improve, demolish or repair any structure, prior to its issuance, also requires ttie applicantfor such permitto file a signed statement that he is licensed pursuantto the provisions ofthe Contractor s License Lavii (Chapter 9, commendingwith Secuon 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penally of not more than five hundred dollars ($500)) ]8 I have and Will maintain workers'compansation, as requiredby^Section 3700 of the LaborCode, for ihe performance oHhe work for whigh ttus oemit number are Insurance Co ^''*"<?-^t'g— ^-t.<->A c- Policy No \_ I o" ^ ^\ Workers' Compensation Declaration / herehy affirm unrfer penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self insure for workers' compensation as provided by Section 3700 of ihe Labor Code for the performance of the work for which this perm it is issued lit IS issued My workers' compensato raurjflce camer and policy Expiration Date / i This seciion need not be ccmpleied if ihe permit is for one hundred dollars ($100) or less O Certificate of Exemption 1 certify that in the performance of the work for which this permit is issued, 1 shall not employ any peison in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employerto criminal penalties and civil fines upto one hundred thousand dollars (&100,000), in addition to the cost of compensation, damataes as prowled^orin^ctio^706 ofthe Labor code, interest and attorney's fees CONTRACTOR SIGNATURE ySA—T ^fj/^^ / Y OAGENT DATE WW (3 I hereby affinn that I am exempt from Contractor's bcense Law for the following reason n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, ihe owner builder will have the burden of proving that he did not build or improve for the purpose of sale) • I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant io the Contractor's Ucense Law) • I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement • Yes • No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) io provide the proposed construction (include name address / phone / contractors license number) 4 I plan to provide portions of the worts, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors license number) 5 I will provide some of the vrork, but I have contracted (hired) the following persons to provide the woric indicated (include name / address / phone / type of wori() >g;f PROPERTY OWNER SIGNATURE •AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registration form or nsk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acf • Yes • No Is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management distncP O Yes • No Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site'' • Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby aflirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name l'\ (SW€_^ Lender's Address I ceitily that I have readtheapplicabonandstate thattheabove infoimaton IS coirectandttiatttieintbtmatonon ttie plans isacc^ I agree to comply with all Ci^oidinancesand State laws relabngto buildingconstrucbon I hereby authonze representative of the City of Carisbad to enter upon the above mentioned property tor inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA pemnit is required Ibr excavations over 5'0' deep and demolition or constmction of structures over 3 stones in height EXPIRATION Every pemiit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void i the building or work authonzed by such permit is not commenced within 180 days from the date of suoh pemiit or if ihe building or vrak aumonzed by such permit is suspended or abandoned at any time after the mik is commenced fbr a penod of 180 days (Section 106 4 4 Unifonr Building Code) yfiTAPPLICANT'S SIGNATURE DATE Inspection List Permit* CB130904 Type RESDNTL RAD MILES RESIDENCE 104 SF ADDITION TO 1ST FLOOR Date Inspection Item Inspector Act 07/17/2013 89 Final Combo -Rl 07/17/2013 89 Final Combo PY AP 06/20/2013 17 Intenor Lath/Drywall PY AP 06/20/2013 18 Extenor Lath/Drywall PY AP 06/18/2013 84 Rough Combo PY AP 06/03/2013 83 Roof Sheathing/Ext Shear MC AP 05/22/2013 11 Ftg/Foundation/Piers PY AP Comments Thursday, July 18, 2013 Page 1 of 1 EsGil Corporation In (Partnersfiip wttfi government for (BuiCiCing Safety DATE 04/29/13 • >PPtl^?>^NT JURIS. JURISDICTION Carlsbad d-mXNREViEWER • FILE PLAN CHECK NO 13-0904 SET II PROJECT ADDRESS 2414 Byron Place PROJECT NAME Room Addition (Infill of Existing Back Porch jfor Miles Residence XI The plans transmitted herewith have been corrected where necessary and substantially connply with the junsdiction's building and fire codes I I The plans transmitted herewith will substantially comply with the junsdiction's building and fire codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to fonward to the applicant contact person I I The applicant's copy of the check list has been sent to EsGil Corporation staff did not advise the applicant that the plan check has been completed I I EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Email Mail Telephone Fax In Person • REMARKS By Ray Fuller Enclosures EsGil Corporation • GA • EJ • PC (P) 04/22/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partnersfiip wttfi government for (ButCding Safety DATE 04/16/13 • APPLICANT ja JURIS JURISDICTION Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-0904 SET I PROJECT ADDRESS 2414 Byron Place PROJECT NAME Room Addition (Infill of Existing Back Porch )for Miles Residence I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building and fire codes I I The plans transmitted herewith will substantially comply with the junsdiction's building and fire codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck ^ The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person ^ The applicant's copy of the check list has been sent to Seth Hoenig Post Office Box 1958 Carlsbad, Ca 92018 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed IXI EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Seth Hoenig Telephone # (760) 518-9668 Date contacted 1^ ^^^^^ * (760)434-2148 ^^Ma,l telephone Fax In Person ^0VnV^6eY>\Q (S) Q ^n U OX)^ • REMARKS J ^ J ^ By Ray Fuller Enclosures EsGil Corporation • GA • EJ • PC 04/09/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-0904 04/16/13 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO 13-0904 JURISDICTION Carlsbad PROJECT ADDRESS 2414 Byron Place FLOOR AREA Addition (infill of Existing Porch 104 STORIES 2 Existing HEIGHT No Change REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE PLANS RECEIVED BY ESGIL CORPORATION 04/09/13 DATE INITIAL PLAN REVIEW COMPLETED 04/16/13 PLAN REVIEWER Ray Fuller FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineenng Department, Fire Department or other departments Clearance from those departments may be required pnor to the issuance of a building permit Present California law mandates that construction comply with the 2010 edition ofthe California Code of Regulations (Title 24), which adopts the following model codes 2009 IRC, 2009 IBC, 2009 UPC, 2009 UMC and 2008 NEC The above regulations apply, regardless ofthe code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copv) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 13-0904 04/16/13 1 Please make all corrections on the onginal tracings, as requested in the correction list Submit three sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1) Deliver all corrected sets of plans and calculations/reports directly to the City ofCarlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92009, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2) Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Dnve, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete 2 Verify final sets of architectural sheets will be signed by designer and that the structural sheets and calculations will be stamped and signed by engineer of record also Even though you provided what appear to be a previous design for across the street the plans and calculations would still need to be stamped and signed with a current expiration date 3 The proposed plan did not address the lateral as to comply with conventional framing the plans must reflect minimum 2'8" braced wall panels starting within 8 ft of each end of each braced wall line 4 Need to provide shear transfer details to include edge nailing of the roof diaphragm to full depth blocks at the plate lines and transfer from blocks to plates I e A-35's with spacing noted 5 Show support for all point loads i e check that the foundation is adequate to support point loads Per the City of Carlsbad (listed below) unless a soils report is provided must us 1000 psf for design It is unclear how existing footings can support point loads using 1000 psf in design See 7" PLM for example 6 Could not determine how a HU812 will work as shown on framing plan on sheet 3 as would need to be skewed'? • CITY OF CARLSBAD REQUIREMENTS 7 All new residential buildings, including additions, require a soils report An update letter is required if the report is more than 3 years old If a room addition is less than 500 sq. ft. in area and only one story, then a soils report is not required The maximum allowable soil beanng value used in any design must be 1000 psf for this exception Carlsbad 13-0904 04/16/13 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes ( ) No ( ) The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Ray Fuller at Esgil Corporation Thank you Carlsbad 13-0904 04/16/13 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO 13-0904 PREPARED BY Ray Fuller DATE 04/16/13 BUILDING ADDRESS 2414 Byron Place BUILDING OCCUPANCY R3 TYPE OF CONSTRUCTION VB BUILDING PORTION AREA (Sq Ft) Valuation Multiplier Reg Mod VALUE ($) Addition 104 131 73 13,700 Air Conditioning Fire Spnnklers TOTAL VALUE 13,700 Jurisdiction Code cb By Ordinance Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review I I Repetitive Fee Repeats 0 Complete Review • Other j—I Houriy EsGil Fee • Structural Only Hr @ * $166 07 $107 95 $93 00 Comnnents Sheet 1 of 1 macvalue doc + PLAN CHECK Community & Economic CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 ww/w carlsbadca gov DATE: 04/08/13 PROJECT NAME: MILES RESIDENCE PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2414 BRYON PL VALUATION: $13,700 PROJECT ID: CB130904 APN: 212-143-31 Zl This plan check review is complete and has been APPROVED by the ENGINEERING y,„j Division. By: KATHLEEN LAWRENCE 04/08/13 A Final Inspection by the Division is required Gves ENO ' "i This plan check review is NOT COMPLETE. Items missing or incorrect are listed on L_-_j the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more ofthe divisions listed below. Approval from these divisions may be required prior to the issuance ofa building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked , PLANNING , 760-602-4610 ENGINEERING 760-602-2750 ; FIRE PREVENTION ^, i 760-602-4665 j 1 Chns Sexton ' ' 760-602-4624 Chns Sexton@carlsbadca gov I'y'l Kathleen Lawrence — - 760-602-2741 Kathleen LawrenceOcarlsbadca gov 1 Greg Ryan ' J 760-602-4663 Gregorv Rvan@carlsbadca gov ! Gina Ruiz 760-602-4675 Gma Rui2@carlsbadca gov ["""] Linda Ontiveros 760-602-2773 Lmda Ontiveros@carlsbadca gov c Cindy Wong 760-602-4662 vnthia Wong@carlsbadca gov • J n [ Dominic Fieri 760-602-4664 )ominic Fieri@carlsbadca gov Remarks: ^ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www carlsbadca gov ENGINEERING Plan Check for CBI 30904 Date 04/08/13 Project Address 2414 BRYON PL APN 212-143-31 Project Description 104 SF ADDITION Valuation $13,700 ENGINEERING Contact Kathleen LawrencB Phone 760-602-2741 Email kathleen.lawrence@carlsbadca.gov Fax 760-602-1052 I I RESIDENTIAL INTERIOR TENANT IMPROVEMENT ill RESIDENTIAL ADDITION MINOR (<$20,000.00) • PLAZA CAMINO REAL • CARLSBAD PREMIER OUTLETS • COMPLETE OFFICE BUILDING • OTHER: CELL ANTENNAS OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY- KATHLEEN LAWRENCE REMARKS NO ADDITIONAL ENG. FEES- DATE 04/08/13 Notification of Engineering APPROVAL has been sent to . via EMAIL - on 04/08/13 (E-36 Page 1 of 1 REV 4/30/11 PLANNING DIVISION Development Services Planning Division CITY OF BUILDING PLAN CHECK Development Services Planning Division CITY OF APPROVAL 1635 Faraday Avenue CARLSBAD P-29 (760) 602-4610 www carlsbadca eov DATE: 4/9/13 PROJECT NAIVIE: ADDITION PROJECTID: PLAN CHECK NO: CB130904 SET#: ADDRESS: 2414 BYRON PL APN: ^ This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required • Yes ^ No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance ofa building permit. Resubmitted plans should include corrections from all divisions. • This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: SETHH0ENIG@GIV1AIL.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING : . 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chns Sexton 760-602-4624 Chns Sexton@carlsbadca gov Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 1 Greg Ryan 760-602-4663 Gregory Rvan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov rn Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic Fien@carlsbadca gov Remarks: PERMIT NO. CB 130904 LOCATION 2414 Byron Place Carlsbad, CA 92008 SUBJECT Existing Post-Tensioned Slab The point loads on the existing post-tensioned slab from new beams and posts are adequate to support the loads applied. The new footing design is adequate to support the loads applied as shown on the approved plans (permit no. CB 130904). The presumptive load beanng value of the foundation matenal is 1500 PSF and the concrete strength is 2500 psi. The pier footings shown on the plans at the points under the existing post-tensioned slab are not required per the above aforementioned statement Brandon Miles 760 476 1883 CB130904 2414 BYRON PL MILES RESIDENCE (Cs (Z/cj^t 7;/ H\\f\l ^tiVTW. DU.^5r^«-(- ^/S^L^T^c,3 b\l) li fSSULb sw /3- /33 )^ISSUED •cv Approved / ' Date By BUIU3ING PLANNING ENGINEERING fl<fi3 AO- FIRE Expedite? Y N AFS Checked by HazMat APCD Health Forms/Fees sent Reed Due? By Encina Y N Frre Y N HazHealthAPCD Y N PE&M V N School . Y N Sewer Y N Stormwater Y N Special Inspection Y N CFD Y LandUse CFD Y LandUse Density ImpArea FY Annex Factor PFF Y ( N) Comments Date Date Date Date Building Planning Engineenng Fire Need? 1 AtW(a- Tl€^ I -m (Otjuy>c«r' Ib^one b Done • Done. • Done • Done • Done