Loading...
HomeMy WebLinkAbout2424 BADGER LN; ; CB012608; PermitL '08-21 -2001 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad ic 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 Mobile Home Building Permit Permit No: CBO12608 2424 BADGER LN CBAD MOHO Sub Type: INSTALL Status: ISSUED 2091 100400 Lot #: 0 Applied: 08/06/2001 $0.00 Construction Type: NEW Entered By: CB Reference #: Plan Approved: 08/21/2001 0 Structure Type: Issued: 08/21/2001 0 Bathrooms: 0 Inspect Area: RYLAND HOMES- SALES TRAILOR Applicant: RYLAND HOMES OF CALIFORNIA STE 200 5740 FLEET ST CARLSBAD CA 92008 760 603-8001 Owner: TERRACES AT SUNNY CREEK L L C Total Fees: $140.00 Total Payments To Date: $0.00 Balance Due: $140.00 Mobile Home Issuance Fee $20.00 Add'l Recl. Water Con. Fee $0.00 Earthquake Bracing Fee $0.00 Meter Fee $0.00 Coach Setup Fee $1 00.00 SDCWA Fee $0.00 CabandRanada Fee $0.00 CFD Payoff Fee $0.00 Private Garage Fee $0.00 PFF $0.00 Awning/Carport Fee $0.00 PFF (CFD Fund) $0.00 Porch Fee $0.00 License Tax $0.00 Fence Over 6ft $0.00 License Tax (CFD Fund) $0.00 Other Building Fee $0.00 Traffic Impact Fee $0.00 Building Permit $0.00 Traffic Impact (CFD Fund) $0.00 Plan Check $0.00 Plumbing Fee $0.00 Park in Lieu Fee $0.00 Electrical Fee $20.00 Bridge Fee $0.00 Mechanical Fee $0.00 Pot. Water Con. Fee $0.00 Housing Impact Fee $0.00 Meter Size Housing InLieu Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Master Drainage Fee: $0.00 Recl. Water Con. Fee $0.00 Sewer Fee: $0.00 Meter Size Additional Fees: $0.00 TOTAL PERMIT FEES $140.00 FINAL APPROVAL Inspector: = Date: &/ Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'ImposTon" of fees, dedications, reservations, or other exactions hereafter collectively refened to as "feedexactions." You have 90 days from the date this permit was issued to protest imposition of these feeskxactions. If you protest them, you must Mow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified feedexactions DOES NOT APPLY to water and sewer connection fees and Capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any feedexactions of which you have previously been oiven a NOTICE similar to this. or as to which the statute of limitations has previously otherwise elcpired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NOd@o/$ (106 EST. VAL. Plan Ck. Deposit Validated By cv , Date 31 / VI Assessor's Parcel # Existing Use Proposed Use Description of Work SO. FT. #of Stories # of Bedrooms # of Bathrooms I Name Address city Statelzip Telephone f OMPANY NAM (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he IS licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged 1 A (c(7YO r applicant for a permit subjects / c Name Addrex City Statelzip Telephone # State License # cSq(fl qT License Class 6 City Business License # --/ Designer Name Address City Statelzip Telephone State License # I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is e work for which this permit is issued. -. issued. My worker's co Insurance Company (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS) to become subject to the Policy No. L). Expiration Date /%c: , and shall subject an employ ges as provided for in Section s up to one hundred attorney's fees. I hereby affirm that I am e 0 J, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044. Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. 4. number I contractors license number): 5. of work): he Contractor's License Law for the following reason: I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person Ifirm) to provide the proposed construction (include name I address I phone number I contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type Business and Professions Code for this reason: PROPERTY OWNER SIGNATURE DATE S&TlOFI FOR Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citv of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in helght. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is ate of such permit or if the building or work authorized by such permit IS suspended or abandoned at any time after the work is ion 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE T/$b/ WHITE: File YELLOW: Applicant PINK: Finance t City of Carlsbad Bldg Inspection Request For: 1 011 6/200 1 Permit# CB012608 Title: RYLAND HOMES- SALES TRAILOR Description: Type: MOHO Inspector Assignment: JC Sub Type: INSTALL Phone: 0000000000 Job Address: 2424 BADGER LN Suite: Lot 0 Inspector: d Location: APPLICANT RYLAND HOMES OF CALIFORNIA Owner: TERRACES AT SUNNY CREEK L L C Remarks: Total Time: Requested By: DAVE Entered By: CHRISTINE CD Description Act Comments 61 Footing y/c 79 #%H@L E -A@ -4- Associated PCRs lnsoection History Date Description Act lnsp Comments 09/28/2001 22 Sewerwater Service AP JC 09/20/2001 22 Sewerwater Service CA JC 0911 1/2001 I1 FtglFoundationPiers AP JC . . .) PLANNING/ENGINEERlNG APPROVALS PERMIT NUMBER CB 0 I2 66% TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMlNO REAL ( < $1 0,000.00) CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING PLANNER DocSIMisformsIPlanning Engineering Approvals c OESIGN CALCUIATIONS FOR: 12' WIDE COMMERCIAL COACH PAD / PIER I ANCHOR SYSTEM (70 MPH / EXP 'C' WIND, TYPE 4 SOIL) ADORESS OF INSTALLATION: PREPARED FOR: MOBILE MODULAR MANAGEMENT CORP. 5700 US POSITAS ROAD LIVERMORE, CALIFORNIA 94550 11450 MISSION BLVD. MlRA LOMA, CALIFORNIA 91752 PREPARED BY: ACUMEN ENGINEERING, INC. 12808 SOUTH, 600 EAST DRAPER, UTAH 84020 (801) 571-9877 The information in these calculations is proprietary. They may not be reprinted, distributed or used for any purpose without the expressed written permission of Mobile Modular Management Corporation. JUN 2 2 2081 TABLE OF CONTENTS 12' Wide Commercial Coach (70'C' Wind, Type 4 Soil) ITEM SHEET DESIGN LOADS 3 PADlPIER DESIGN Wood Pad Analysis PadlPier Spacing 4 5 GROUND ANCHOR DESIGN 6 DESIGN LOADS A.) Dead Loads 1 .)Roof 2)FIoor 3.)Exterior Walls 4.)Partition Load B.) Live Loads 1 .)Roof 2)Floor 3.)Wind: 70 mph, Exp'C' Primary Frame: Uplifi: 4.)Seismic Zone: 4' (Allowable Stress Design) 6 psf 8 psf 6 psf 10 psf 20 psf SO psf l200W Concentrated Load Design Pressure (ps9 Ce cq (2s I P=(Ce)(Cq)(qs)(l) 1.06 1.3 12.6 1.0 17.4 1.05 0.8 12.6 1.0 10.7 Design Base Shear Ca R" V=((3.0)(Ca)/(R)(1.4))0 0.44 5.6 0.168 Does not include 'Near Source Factor' as required by the 1997 UBC for buildings located within 1 Okm of a known seismic source. c1 Ordinary Braced Frame System , 1 T T I I 1 I 1 I 1: r , ! , PADIPIER SPACING Input Data: Roof Live Load: (RI) Roof Dead Load: (Rd) Exterior Wall Dead Load: (Wd) Floor Live Load: (FI) Floor Partition Load: (Fp) Floor Dead Load: (Fd) Module Width: (W) Sidewall Height: (H) Pad/Pier Capacity: (P) (12’ Wide, 70C Wind, Type 4 Soil) 20 psf 6 psf 6 psf 50 psf 10 psf 8 psf 11.83 feet a feet 4000 Jbs Ca I cu la ti o n s : Weight of Exterior Wall: We=@VdxH) Load Acting on Outside Chassis Wo=((RJ+Rd+FJ+Fp+Fd)(W/2))+We 604.0 plf Maximum Spacing of Piers on 48 plf Main Rails: Outside Main Rails: S=PMlo 6.62 feet GROUND ANCHOR DESIGN Input Data: Design Wind Pressure: (P) Seismic Load Factor: (SI) Roof Dead Load: (Rd) Floor Dead Load: (Fd) Exterior Wall Dead Load: (Wd) Roof Live Load used in Seismic Calculation: (RI) Partition Load used in Seismic Calculation: (Pd) floor Live Load used in Seismic Calculation: (FI) Building Depth: (D) Exterior Wall Height: (H) Roof Depth: (R) Floor Depth: (F) SkirtingFoundation Height: (S) Pull-Out Capacity of Anchor: (Pu) Angle of Anchor Installation: (A) Strap Design Capacity: (Sd) Safety Factor: (Fs) Calculations: Ground Anchor CaDacitv; Design Capacity of Anchor. Pc = PulFs Strap Design Capacity: (Sd) Goveming Capacity: (Gc) Lateral Load Resistance of AnchorlStrap Assembly: M = Gc x cos(A) 17.4 psf 0.168 W 6Psf 8 psf 6 psf 0 Psf 11.83 feet 8 feet 1 feet 0.67 feet 3.33 feet 7125 Ibs 45 degrees 1.5 6300 Ibs (1 2 Wide, 7OC Wnd, Type 4 Soil) 4750 lbs 6300 Ibs 4750 Ibs 3359 Ibs GROUND ANCHOR DESIGN (cont.) Building Length: (L) (feet) 32 44 Calculations: Transverse Load: Base Shear Due to Wind: Base Shear Due to Seismic: Vw= P x (R + F + H + SM) XL (lbs) 6311 8678 9861 11834 13017 Vs = (SI)((LxD)(Rd+Fd+RI+Pd+FI)+ -- ((L+D)x2xHxWd)) (lbs) 2233 2999 3382 4020 4403 Governing Transverse Base Shear: (V) (Ibs) 631 1 8678 9861 11 834 1301 7 l,onaitudinal Load: Base Shear Due to Wind: W= Px (R + F + H + S/2)xD (Ibs) 2333 2333 2333 2333 2333 Base Shear Due to Seismic Loading: (Ibs) 2233 2999 3382 4020 4403 Governing Long. Base Shear: (VI) (Ibs) 2333 2999 3382 4020 4403 Ground Anchor Quantitv: In Each Transverse Direction: Nt = VNL 2 4 4 4 4 In Each Longitudinal Direction: NI=VVVL 1 1 2 2 2 Total Quantity of Anchors Required: 6 10 12 12 12 In Each Transverse Diredion: In Each Longitudinal Direction: Lt=(WM)/W))Fs (Iw 0674 4589 5214 6257 6883 Ll=((WNl)/cos(A))Fs (Ibs) 4935 6343 3577 4252 4657 ALTERNATE GROUND ANCHOR DESIGN Input Data: Design Wind Pressure: (P) Seismic Load Factor: (SI) Roof Dead Load: (Rd) Floor Dead Load: (Fd) Exterior Wall Dead Load: (Wd) Roof Live Load used in Seismic Calculation: (RI) Partition Load used in Seismic Calculation: (Pd) Floor Live Load used in Seismic Calculation: (FI) Building Depth: (0) Exterior Wall Height: (H) Roof Depth: (R) Floor Depth: Q SkirtingEoundation Height: (S) . Pull-Out Capacity of Anchor: (pu) Angle of Anchor Installation: (A) Strap Design Capacity: (Sd) Safety Factor. (Fs) Calculations: Ground Anchor CaDacitv: Design Capacity of Anchor: Pc = Pu/Fs Strap Design Capacity: (Sd) Governing Capacity: (Gc) Lateral Load Resistance of Anchor/Stnp Assembly in Longitudinal Direction: M = Gc x cos(A) Lateral Load Resistance of Anchor/Strap Assembly in Transverse Diredion: VT = Gc x COMA) Lateral Load Resistance of Anchor/Strap Assembly in Transverse Diredion: (30 Degree Maximum Variance From Principal Axis) VTT = Gc x cos(A) x c06(30) 17.4 psf 0.168 W 6PSf 8 Psf 6 psf ow 10 w ow 11.83 feet 8 feet 1 feet 0.67 feet 3.33 feet 7125 Ibs 45 degrees 6300 Ibs 1.5 4750 Ibs 6300 Ibs 4750 Ibs 3359 Ibs 3359 Ibs 2909 fbs 4 ALTERNATE GROUND ANCHOR DESIGN (cont.) Building Length: (L) (feet) Calculations: Transverse Load: Base Shear Due to Wind: Base Shear Due to Seismic: Vw = P x (R + F + H + S/2)x L (Ibs) Vs = (Si)((Lxo)(Rd+Fd+RI+Pd+Fl)+ . - ((L+D)*WdN (IW Governing Transverse Base Shear (V) (Ibs) Lonaitudinal Load: Base Shear Due to Wind: VW = P x ( R + F + H + S/2) x D (Ibs) Base Shear Due to Seismic Loading: (Ibs) Governing Long. Base Shear: (VI) (lbs) Ground Anchor Quanti: In Each Transverse Direction: Nt = VNT (Maximum of 2 Anchors) In Each Transverse Direction at 30 Degrees: In Each Longitudinal Direction: Nl=VWL Total Quanti of Anchors Required: Ntt = (v-20TT))rn Gmt In Each Transverse Direction: Lt=((V/(Nt+Ntt)/cos(A))Fs (Ibs) In Each Transverse Direction: (30 Degrees) Lt=(V/(Nt+Ntt)/cos(A))/ws(3O)Fs (lbs) In Each Longitudinal Direction: Ll= ((Vl/Nl)lcos(A))Fs (Ibs) 32 631 1 2233 831 1 2333 2233 2333 2 0 1 8 6674 0 4935 44 8678 2999 8678 2333 2999 2999 2 2 1 10 4589 5299 0343 50 9861 3382 9861 2333 3382 3382 2 2 2 12 521 4 0021 3577 60 11834 4020 11834 2333 4020' 4020 2 2 2 12 6257 7225 4252 66 1301 7 4403 13017 2333 4403 4403 2 4 2 16 4589 5299 4857 ... 0 I C -r .- L -0 .- . - mal OL 10 OL OQ, E r. i Ln5 W n 5 I a 0 a 3E s - lLI 0 n :I ii m i i @&I i i @ @ I I I i ‘I . _- _- I? I I' =+Q+ i* ! i i i I I I I -.\ t L - P c i! r; 3 n w 't d M . I b. 414 SAN DIEGO DIVISION 5740 Fleet St. Suite 200 Carlsbad, CA 92088 (760) 603-8001 FAX (760) 603-8005 LETTER OF TRANSMITTAL Date: August 14,200 1 To: John Mildbrandt Company: City of Carlsbad Re: Sales Trailer Re-Submittal From: C. Blair Pruett Dear John, Please see the attached Sales Trailer conceptual plan for Sunny Creek TR 96-02. After speaking with Pat Kelley, I have drafted a letter stating Ryland’s intention to hook into the sewer once it is signed off by the City of Carlsbad. Please let me know what the fees are for the sales trailer permit and I will come back in with a check once you have blessed the plans. Should you have any additional questions please do not hesitate to call. Thank you for your time, Blair RYLAND HOMES 5740 Fleet Street Suite 200 Carlsbad, California 92008 (760) 603-8001 Tel (760) 603-8005 Fax August 14,2001 Mr. Pat Kelly City of Carlsbad, Building Inspections 163 5 Faraday Avenue Carlsbad, CA 92008 Re: Montemar at Sunny Creek, Sales Trailer Dear Pat- Per our conversation, as part of Ryland's application for a permit to install a Sales Trailer (with a restroom facility), it will be Ryland's duty to provide a temporary restroom (ADA accessible) until the sewer system is completed. Upon completion, it will be Ryland's responsibility to hook the sales trailer into the city-approved sewer. Respectfully Submitted, C. Blair Pruett Forward Planner ri-- - -I I I I ! I I I I EVIDENCE Of INSURANCE