Loading...
HomeMy WebLinkAbout2426 CORTE AZUL; ; CB111389; Permit11-07-2011 Job Address- Permit Type. Parcel No- Valuation Occupancy Group- 11/07/2011 # Dwelling Units Bedrooms- Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB111389 Building Inspection Request Line (760) 602-2725 2426 CORTE AZUL CBAD RESDNTL 2161602710 $200,842 74 Sub Type: Lot# Construction Type. Reference #: 1 Structure Type. 4 Bathrooms- LA COSTA CONDOMINIUMS PLAN 3 1825 SF LV//448 SF GAR//71 SF DECK CONDO 0 5B CT200028 MF2-4 35 Status- Applied- Entered By- Issued. Inspect Area- Ong PC#- Plan Check # ISSUED 06/27/2011 JMA Plan Approved: 11/07/2011 PCI10024 Applicant- LIGHTHOUSE HOMES, INC GREG LINHOFF 3529-2B CANNON RD., #519 OCEANSIDE 92056 760-643-0034 Owner LIGHTHOUSE HOMES, INC. 3529-2B CANNON RD. #519 OCEANSIDE CA 92056 760-643-0034 Building Permit $1,013.57 Meter Size Add1 Building Permit Fee $0.00 Add'l Reel. Water Con. Fee $0 00 Plan Ctieck $658.82 Meter Fee $331 00 Add'l Plan ChecK Fee $0.00 SDCWA Fee $4,492 00 Plan Check Discount $0.00 CFD Payoff Fee $0 00 Strong Motion Fee $20.08 PFF (3105540) $3,655 34 Park in Lieu Fee $4,636.00 PFF (4305540) $3,374.16 Park Fee $0.00 License Tax (3104193) $0 00 LFM Fee $310.00 License Tax (4304193) $0 00 Bndge Fee $0 00 Traffic Impact Fee (3105541) $2,200 00 Other Bndge Fee $424.00 Traffic Impact Fee (4305541) $0 00 BTD #2 Fee $0 00 Sidewalk Fee $0.00 BTD #3 Fee $0 00 PLUMBING TOTAL $161.00 Renewal Fee $0 00 ELECTRICAL TOTAL $41 25 Add'l Renewal Fee $0 00 MECHANICAL TOTAL $78 50 Other Building Fee $0 00 Housing Impact Fee $0 00 HMP Fee $0 00 Housing InLieu Fee $0.00 Pot Water Con Fee $3,549.00 Housing Credit Fee $0 00 Meter Size D5/8 Master Drainage Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Sewer Fee $0 00 Reel Water Con. Fee $0.00 Additional Fees $0 00 Green Bldg Stands (SB1473) Fee $8.00 Fire Spnnkler Fees $0 00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $24,952.72 Total Fees: $24,952 72 Total Payments To Date: $24,952 72 Balance Due: $0.00 Inspector FINAL APPROVAL Date. Clearance- NOTICE Please taKe NOTICE thai approval of your project includes ttie "Imposition" of fees, dedications, reservations, or ottier exactions tiereafter collectively referred to as lees/exactions" You have 90 days from ttie date ttiis permit was issued to protest imposition of ttiese fees/exactions If you protest tfiem, you must follow tfie protest procedures set foith in Government Code Section 66020(a), and file the protest and any other required information with the City Manager tor processing in accordance with Car!,=bad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul then imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or ser/ice fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have sreviouslv been given a NOTICE similar to this, or as to which the statute of limitations has previously othenA<ise expired 11-07-2011 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW110271 Job Address- Permit Type- Parcel No- Reference #. CB# Project Title: 2426 CORTE AZUL CBAD SWPPP 2161602710 LA COSTA CONDOMINIUMS Applicant: GREG LINHOFF C/O LIGHTHOUSE HOMES, INC. 3529-2B CANNON RD #519 92056 760-643-0034 Emergency Contact: GREGG LINHOFF Lot#- Status Applied: Entered By Issued: Inspect Area Tier Pnonty Owner LIGHTHOUSE HOMES, INC. 3529-2B CANNON RD. #519 OCEANSIDE CA 92056 760-643-0034 ISSUED 06/29/2011 JMA 11/07/2011 1 M 760-643-0034 SWPPP Plan Check SWPPP Inspections Additional Fees $0.00 $208 00 $0 00 TOTAL PERMIT FEES $208.00 Total Fees. $208.00 Total Payments To Date. $208 00 Balance Due: $0.00 FINAL APPROVAL DATE^^!SWcLEAFyE SIGNATURE__/^^-^_^ Inspection List Permit#: CB111389 Type: RESDNTL CONDO Date Inspection Item 03/18/2013 89 Final Combo 12/05/2012 39 Final Electncal 05/30/2012 82 Drywall/Ext Lath/Gas Test 05/25/2012 17 Intenor Lath/Drywall 05/24/2012 17 Intenor Lath/Drywall 05/21/2012 16 Insulation 05/18/2012 84 Rough Combo 05/03/2012 13 Shear Panels/HD's 04/25/2012 16 Insulation 04/17/2012 15 Roof/Reroof 03/22/2012 13 Shear Panels/HD's 03/22/2012 14 Frame/Steel/Bolting/Weldin 03/21/2012 16 Insulation 03/15/2012 24 RoughrTopout 03/08/2012 16 Insulation 03/07/2012 16 Insulation 03/07/2012 17 Intenor Lath/Drywall 02/13/2012 17 Interior Lath/Drywall 02/10/2012 13 Shear Panels/HD's 01/03/2012 11 Ftg/Foundation/Piers 12/09/2011 21 Underground/Under Floor 12/09/2011 22 Sewer/Water Service Inspector PY PY PY PY PY PY MC PY PY PY PY PY PY PY PY PY PY PY PD PY PY PY Act AP PA AP CA PA AP AP AP PA AP PA PA PA PA PA PA PA PA PA AP AP AP LA COSTA CONDOMINIUMS: PLAN 3 1825 SF LV//448 SF GAR//71 SF DECK Comments BLDG 3 PRE-ROCK AT STAIRS AT STAIRS Tuesday, March 19, 2013 Page 1 of 1 ^ CITY OF CARLSBAD Building Department INSPECTION RECORD INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB CALL PRIOR TO 4:00 P.M. FOR NEXT WORK DAY INSPECTION CB111389 2426 CORTEAZUL LA COSTA CONDOMINIUMS PLANS 1825 SF LV//448 SF GAR//71 SF DECK RESDNTL CONDO Lot# GREG LINHOFF RECORD COPY FOR BUILDING INSPECTION CALL: 760-602-2725 APPROVED TO COVER DATE: \ ( in {) [ [nil Type of Inspection Date Inspector Notes BUILDING its FOUNDATION REINFORCED STEEL MASONRY • GROUT-• WALL DRAINS TILT PANELS POUR STRIPS COLUMN FOOTINGS SUBFRAME • FLOOR • CEILING ROOF SHEATHING EXT. SHEAR PANELS FRAME INSULATION /y^ EXTERIOR LATH 7^ INTERIOR LATH & DRYWALL FINAL PLUMBING • SEWER AND Bl/CO • Pl/CO UNDERGROUND • WASTE • WATER TOPOUT^^J2^WASTE ^WATER TUB AND SHOWER PAN ^^GAS TEST • GAS PIPING • WATER HEATER • SOLAR WATER FINAL ELECTRICAL • ELECTRIC UNDERGROUND • UFER ROUGH ELECTRIC WALLS ROUGH ELECTRIC CEILING • ELECTRIC SERVICE • TEMPORARY • BONDING • POOL PHOTO VOLTAIC FINAL MECHANICAL UNDERGROUND DUCTS & PIPING 6^/n/^ UCT & PLEM. • REF. PIPING HEAT-AIR COND. SYSTEMS VENTILATING SYSTEMS FINAL CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED FINAL Sign When Appropriate Building Dept. {Inspections) (760) 602-2725 Fire Department (760) 602-4660 Planning Department (760) 602-4602 Engineering Dept. (Inspections) (760) 438-3891 Building Inspectors (7am-4pm) (760) 602-2700 ' f f t J/ CIMWD (760) 438-2722 Ext 7151 —'—r—T ' REV 8/2009 1635 Faraday Ave. • Carlsbad, CA 92008 • 760-602-2700 • www.carlsbadca.gov SEE BACK FOR SPECIAL NOTES