Loading...
HomeMy WebLinkAbout2427 LA COSTA AVE; B; CB023675; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB023675 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Building Inspection Request Line (760) 602-2725 2427 LA COSTA AV CBAD St: B RESDNTL Sub Type: 2162405513 Lot#: $3,885.00 Construction Type: Reference #: 0 Structure Type: O Bathrooms: WALTERS RES/129.5SF LOFT INFIL RAD 0 NEW 0 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check#: ISSUED 12/06/2002 CB 12/19/2002 12/19/2002 PD Applicant: WALTERS VIRGINIA L Owner: WALTERS VIRGINIA L 3939 .12/19/02 ·1002 01. 2427 LA COSTA AVE #8 CARLSBAD CA 92009 943-6379 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Total Fees: $109.26 $53.49 $0.00 $34.77 $0.00 $0.00 $1.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 2427 LA COSTA AVE #8 CARLSBAD CA 92009 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnLieu Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES Total Payments To Date: $34.77 Balance Due: FINAL APPROVAL Date: Clearance: CGP $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $109.26 $74.49 roval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactio You have 90 days from the date this permit was issued to protest imposition of these lees/exactions. If you protest them, you must follow the protest procedure set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any 02 FOR OFFICE USE ONLY PERMIT APPLICATION PLAN CHECK NOLP0z:'£Rp CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. ---=>~9 ........ B~,-l~·--- Plan Ck. Deposit ____ 3,,_"f:_,__~7_,_7_,_ Validated Bv...,.~C~Ez...,..,_ _____ _ Date t2-Cp-Q'7 •.1, . ! ,P,ROaliCT lN~ORt,!ATION Address (include Bldg/Suite #) ).. c.j '2,. l'.) U CO IA Business Name (at this address) legal Description Lot No. Subdivision Name/Number u nits 34 .. 77 Assessor's Parcel # Proposed Use #of Stories # of Bedrooms # of Bathrooms Name ,IJ; F P~QPERT)' QW!'lli!! · · k'/--V Name •$!FcrF'!ll!fil'rAA'O'TOl!F? iiiOM~lltilV•!'IJlli/ll•:·· Address Address ~ Telephone # 9 </3-t "377 Fax# City State/Zip Telephone# City State/Zip Telephone# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law !Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). Name Address City State/Zip Telephone# State License # _________ _ License Class _________ _ City Business License # _______ _ Designer Name Address City State/Zip Telephone State License # _________ _ lll: •,wollk&ilSt:CtiMPENlltlllfis!'i"• Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company______________________ Policy No. ____________ _ Expiration Date _______ _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS) JI CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest and attomey's fees. !t~=~;ill;;O;;;lfo;;,.;.e;,c;.D;;l!C;l;Qll;;• ;;; . .,;,'i;;;,o;tf;;<,=·· =· -;-;-;-;-;-;-;-;==-;-;-;-;-;-;-;-;-;-;-;-;-;-;====-;-;== DATE-;-;======-;-;-;-;- I hereby affirm that I am exempt from the Contractor's License Law for the following reason: J1 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement ... YES ONO 2. I ~/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): ________________________________________________ _ 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): ________ ---+---jf---c-----,--r-;--t-+"""------------------,=-,-t-------------- DATE /2 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8,:. : C'dRITRUCTIOP.r:LlNl>ING,A<IEtlCY; I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME _____________ _ LENDER'S ADDRESS ________________________ _ 11;., Ael'I.ICANT CERTIFICAWN •• I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'08 deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit iss ed by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is t mmenced w1th1n 180 days from tehe date of such permit or 1f the building or work authorized by such permit 1s suspended or abandoned at any time after the work is enced for a penod f 1 O a 1 s t tion 1 06 4 4 Uniform Building Code) / -/ APPLICANT'S SIGNATURE • --\__ (}I DATE / / (J fi'/ (! 7 r I WHITE: File YELLOW: Applicant PINK: Finance lr'f?,-r/ City of Carlsbad Bldg Inspection Request For: 02/10/2003 Permit# CB023675 Title: WALTERS RES/129.SSF LOFT INFIL Description: Type: RESDNTL Sub Type: RAD Job Address: 2427 LA COSTA AV Suite: B Lot Location: APPLICANT WALTERS VIRGINIA L Owner: Remarks: AM PLEASE Total Time: 0 Act Comment Inspector Assignment: PD --- Phone: 0000000000 Inspector: Requested By: N/A Entered By: ROBIN CD 19 Description Final Structural AP ?11//Ai- ------·-------------------------------------- Associated PCRs/CVs CV020853 CLOSED H-ILLEGAL CONSTRUCTION; EXTENSION OF LOFT lnsQection History Date Description Act lnsp Comments 02/04/2003 17 Interior Lath/Drywall AP JM 12124/2002 84 Rough Combo AP PD "{:sGil Corporation In Partnership with Government for Building Safety DATE: DEC.17,2002 JURISDICTION: CARLSBAD PLAN CHECK NO.: 02-3675 SET: 1-S PROJECT ADDRESS: 2427 LA COSTA AVE. PROJECT NAME: SFR ADDITION FOR WALTERS □~ANT c:Q.ld.8Js> D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. [gJ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the attached list are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [gl Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person 0 REMARKS: By: Ali Sadre Enclosures: Esgil Corporation □ GA □ MB □ EJ □ PC log tmsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 , CARLSBAD 02-3675 ,.. DEC. 17,2002 1 1. I All sheets of plans must be signed by the person responsible for their < 2- preparation. (California Business and Professions Code). ., 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which JL adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. 3. Show locations of permanently wired smoke detectors with battery backup: a) Inside each bedroom. 4. 5. 6. 7. b) Centrally located in corridor or area giving access to sleeping rooms. J ') c) On each story. UL- d) When sleeping rooms are upstairs, at the upper level in close proximity to the stair. e) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 310.9.1. Note on the plans that receptacle outlet locations will comply with NEC Art. .JlL· 210-52(a). All bedroom branch circuits now require arc fault protection. Note clearly on the ~ ,-, plans that "Bedroom branch circuits will be arc fault circuit protected." NEC Art.(./4' c.- 210-12(b). ,. Note on the plans: "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing (l'Jl- compliance with the energy calculations." · =~a""b""le window area is not adequate as shown on the plans. Either the fixed wi dow must be changed to a slider, or the existing slider changed to a caseme t window. L EsGil Corporation In Partnership with Government for Building Safety DATE: DEC. 13, 2002 JURISDICTION: CARLSBAD PLAN CHECK NO.: 02-3675 SET:I PROJECT ADDRESS: 2427 LA COSTA AVE. PROJECT NAME: SFR ADDITION FOR WALTERS 0,.--APPb!Ct.NT IQ~U~ □ PLAN REVIEWER □ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: VIRGINIA WALTERS 2427 "B" LA COSTA AVE., CARLSBAD, CA 92008 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: VIRGINIA ("" · NJ Telephone#: 760-943-6379 Date contacted: I .e-/, b I c,.,,_ (by: ic:.... ) Fax #: Mail JTelephone / Fax In Person 0 REMARKS: By: Ali Sadre Enclosures: Esgil Corporation 0 GA O MB O EJ O PC 12/8 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CARLSBAD 02-3675 DEC. 13,2002 GENERAL PLAN CORRECTION LIST JURISDICTION: CARLSBAD PROJECT ADDRESS: 2427 LA COSTA AVE. DATE PLAN RECEIVED BY ESGIL CORPORATION: 12/8 REVIEWED BY: Ali Sadre FOREWORD (PLEASE READ): PLAN CHECK NO.: 02-3675 DATE REVIEW COMPLETED: DEC. 13, 2002 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections on the original tracings and submit two new complete sets of prints to: The Building Department. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. 1. Please specify that the floor area of the addition on plans. 2. Please note this project complies with the 2001 CBC, which adopts the 1997 UBC, 2000 UMC, 1999 NEC & T-24. 3. Please specify the nail size and spacing for the new floor sheathing on plans. 4. Please provide a shear wall details and references on plans. I.e., note the thickness of the plywood, nail size and spacing, anchorage at top and bottom as well as the length. 5. Show an aspect ratio of 2:1 for the shear panels on plans. E.g., 4' min. width required for an 8' plate height. CARLSBAD 02-3675 DEC. 13,2002 6. The openable window area is not adequate as shown on plans. E.g., show how the net required ventilation of 1/20 of the floor area is met. The window frame should be deducted from the calculations of the window area. 7. Provide material specifications for lumber, plywood, bolts, nailing, etc. on plans. 8. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ali Sadre at Esgil Corporation. Thank you. eARLSBAD 02-3675 DEC. 13,2002 • VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: Ali Sadre PLAN CHECK NO.: 02-3675 DATE: DEC. 13,2002 BUILDING ADDRESS: 2427 LA COSTA AVE. BUILDING OCCUPANCY: R3/Ul BUILDING AREA PORTION ( Sq. Ft.) LNINGAREA 130 ADD. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB (i994 UBC Building Perrrit Fee ■ (.1994 UBC Plan Check Fee ill Valuation M.iltiplier By Ordinance Type of Review: D Complete Review D Repettive Fee , D Other D Hourly TYPE OF CONSTRUCTION: VN Reg. VALUE ($) Mid. 3,885 $53.49] $34.77) D Structural Only .__ ___ __,) Hour * [B Repeats Esgll Plan Review Fee $29.95) Comments: Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB O 2 -3 6 7 r ADDRESS2f27 t-A Com} Ava- RESIDENTIAL ADDITION MINOR C < $10,000.00} OTHER ?opr /A} FiU-- PLANNER [) (y,vcl_ 00CSIMISftll'nWPlaMfn9 Engtneerlng Approvals DATE / 2--6-o~ TENANT IMPROVEMENT PLAZA CAMINO REAL ' CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING DATE ( 'c:--6 ·0 L DATE ;z/1.. /45;2 --7-(£)1,.......---