HomeMy WebLinkAbout2428 LAPIS RD; ; CB063547; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
12-26-2006 Pool Permit Permit No: CB063547
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
Project Title:
Applicant:
Building Inspection Request Line (760) 602-2725
2428 LAPIS RD CBAD
POOL
2132321100
$24,814.00
Lot#: 0
Construction Type: NEW
OVERLOCK RES-653 SF POOL/SPA
Owner:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
12/19/2006
LSM
12/26/2006
12/26/2006
MISSION VALLEY POOLS & SPAS OVERLOCK STEPHEN B&JENNIFER F
8284 MIRAMAR RD
SAN DIEGO, CA 92126
619-695-2007
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
El eel rical Fee
Plumbing Fee
Strong Motion Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $404.54
Inspector:
2428 LAPIS RD
CARLSBAD CA 92009
$215.19
$0.00
$139.87
$0.00
$20.00
$27.00
$2.48
$0.00
$0.00
$0.00
$0.00
$404.54
Total Payments To Date: $404.54 Balance Due:
Date: Clearance:
$0.00
NOTICE: Please take NOT ICE that approval of your project includes the "Im positio11' of le s, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
lo/low the protest procedures set forth in Government Code Secr,on 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f hv I iilhir 'h h
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
1,_
FOR OFFICE USE ONLY
PLAN CHECK NO . (!,/5t)03s-47
EST. VAL. ~I I, 'fi:11;.,
Plan Ck. Deposit -r, jq, b"/
Validated By ~
Date ,f r.rpt? I~-/ 1q /'30
Business Name (at this address}
Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
Assessor's Parcel # Existing Use Proposed Use
#of Stories
1(0 BF
-1:,,.J...l....ll..a...~L...U..~::!....--LLL...!....L..L.J.....L...,..,.....£--=-::.-!........L..LLL.!.~.L.!...!<:.!'.....:.....t:=..~,,,,...._....L......"'==:t.....----'~..l:=:-=..L.£~'-:-'-1'---l,l.~.L.Oc,.-=-="-=::..:..,4 City
3. 0 Owner rz(Agent for Owner
Name Address City State/Zip Telephone#
4,~tmr.Y. OW~R s:fe'\/e ovevlcx.AL I 4 01 s J22J
Name Address
CR q')OOe:7J
State/Zip
7 1.P0 ·lpO3· ~D1
Telephone#
CONTRACTOR • COMPANY NAME
(Sec. 7031 .6 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
e e ption. Any violation of Section 7031.5 y any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500]}.
S'Slttn ·dJ 'Y.29 Y r'. cl q21 -2-0t>c.,
Name City State/Zip Telephone #
State License # 4 oq O 'j LJ)
mp# ~'1 License Class _ _,{_=5=--,.3'------City Business License # t Q o 4-q :lo
Designer Name Address City State/Zip Telephone
State License # _________ _
8. WORKERS' COMPENSATION grkers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's c "lpensation insurance carrier and policy nu er are:
Insurance Company . ( l Policy No. O)K./2.LJZJ ;3 "3,()/S1....p Expiration Date 'J / · 0 I
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS}
0 EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subjec to he Workers' Compensation Laws of California.
WARNING: Fail re t secur yrkers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred \l ~ thousand dollar ($1 0,0 ), In addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, Interest and attorney's fees.
,-,SIGNATURE -DATE / 7 " fg -{Ju,
OWNER-. ER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale}.
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s} licensed
pursuant to the Contractor's License Law}.
0 I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
2. I (have / have not} signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm} to provide the proposed construction (include name / address / phone number / contractors license number}:
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number/ contractors license number}:. ______________________________________________ _
5. I will provide some of the work, but I have contracted (hired} the following persons to provide the work indicated (include name / address / phone number / type of work):. _________________________________________________________ _
PROPERTY OWNER SIGNATURE _______________________ _ DATE _________ _
CO.f!1PLETE THIS SECil9N FQJl/J!)f!.:!J§§JllP(lJAL BUILDING PERMITS ONL
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25606, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8, CONS fi'O£T.IQ~(i.A:,,,.,G .,,_,N,,,,C"-Y _____ _
I hereby affirm that there Is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i} Civil Code}.
9..,
I certify that I have read the application and state that the above information Is correct and that the information on the plans is accurate. I agree t o comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for ex ations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by t b ilding Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not comma ed wit~Elays from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenc to a ~i:iclQ_ of 18,0 days (Section 106.4.4 Uniform Building Code). •
APPLICANT'S SIGNATURE -~f.1-~-<.__.)-----------------DATE 11; /Cf Olp
WHITE: File YELLOW: Applicant PINK: Finance
City of Carlsbad Bldg Inspection Request
For 06/27/2007
Permit# CB063547 Inspector Assignment: JM ---
Title: OVERLOCK RES-653 SF POOL/SPA
Description: 110SF RET. WALL (CITY)
Type:POOL Sub Type:
Phone: 8585498033
Job Address: 2428 LAPIS RD
Suite: Lot 0
Location:
APPLICANT MISSION VALLEY POOLS & SPAS
Owner: OVERLOCK STEPHEN B&JENNIFER F
Remarks:
Inspector: -----
Total Time:
CD
59
Description
Final Pool
,,;,ct"" Comment
Requested By: DEANA
Entered By: JANEAN
("
t;1.,_ ~ \.Cefrrµ,-e
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
lnsQection Histort
Date Description Act lnsp Comments
05/31/2007 55 Fence/Pre-Plaster AP JM OK TO PLASTER -ALARMS OK
04/17/2007 11 Ftg/Foundation/Piers WC JM
04/17/2007 61 Footing AP JM OK TO POUR FTG
04/16/2007 11 Ftg/Foundation/Piers co JM SAME AS 4/3/2007
04/03/2007 61 Footing co JM SEE RECORD CARD
01/26/2007 23 Gas/TesVRepairs AP JM EQUIP
01/26/2007 51 Excav/Steel/Bonding/Fence AP JM OK TO GUNITE LIGHTS/EQUIP
01/26/2007 52 Underground Plumbing AP JM
01/25/2007 51 Excav/Steel/Bonding/Fence co JM 18IN LIGHT@ WADE POOL
01/25/2007 98 BMP Inspection co JM
01/23/2007 51 Excav/Steel/Bonding/Fence co JM SIDEYARD FENCE MISSING
l...O
City of Carlsbad
l=lddli¥fi·il:t•#i•i·llii4411,i·I
BUILDING PLANCHECK CHECKLIST
POOLS
BUILDING PLANCHECK NUMBER: CB tX 3 S'f 7
BUILDING ADDRESS: cl-lf P:B l.cyv-::5 (<_.J
PROJECT DESCRIPTION: _Pc...o::..:oc:..I ________ _
ASSESSOR'S PARCEL NUMBER: cf:( 3' -[}:'3)--It
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, information
and/or specifications provided in your submittal;
therefore, any changes to these items after this date,
including field modifications, must be reviewed by this
office to insure continued conformance with applicable
codes. Please review ;,arefully all comments attached,
as failure to com ly with i !ructions in this report can
::u'.Ce ~n of mit to build~aA/2~ (cf
l
ATTACHMENTS
Grading Permit Application
Grading Permit Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal
Checklist and Information Sheet
H:IWORD\OOCS\CHKLSDF'wl B,Jlldjnq PJancheck Cklllll GHl94 form BE Mc
DENIAL
of deficiencies
marked with Make necessary corrections to
plans or spe · ications for compliance with
applicable codes d standards. Submit corrected
plans and/or specifications to this office for review.
Date:
By: Date:
ENGINEERING DEPT. CONTACT PERSON
NAME: JOANNE JUCHNIEWICZ
City of Carlsbad
ADDRESS: 1635 Faraday Avenue
Carlsbad, CA 92008
PHONE: (760) 602-2775
Rev 6r72,'Q'j
1635 Faraday Avenue• Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562
Y6· 3RD✓
a
X ~/ a
I
a
a a a
a a a
a a a
BUILDING PLANCHECK CHECKLIST • POOLS
SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow
8. Existing & Proposed Structures
2. Show on site plan:
A. Drainage Patterns (g) Existing & Proposed Slopes
C. Existing Topography
C. Property Lines
D. Easements
D. Indicate what will happen with
soil excavated from pool area
E. Retaining Walls
(location and height)
Note: If excavated soil is not to be removed from property but regraded on
site, show proposed elevations and slopes.
If any portion of retaining walls are over 4' in height, a separate permit is required.
Retaining Wall Permit CB
3. Include on title sheet:
A. Site Address
_____ Applied for ---Approved
$.Assessor's Parcel Number
Legal Description
Grading Quantities Cut Fill Import/Export
a) If grading is not required, write "No Grading" on plot plan.
4. Project does not comply with the following Engineering Conditions of approval
for Project No.
Conditions were complied with by: Date: ---------
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for grading permit are found in Section 11.06.030
of the Municipal code.
5a. Inadequate information available on Site Plan to make a determination on
grading requirements. Include accurate grading quantities (cut, fill, import,
export).
5b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached.
Note: The Grading Permit must be issued and rough grading approval
obtained prior to issuance of a Building Permit
Page 2 of 2
H:\WOR0\00CS\CHKLS1\Pool Building Plancheck Ckllst CHK24 Form BE.doe Rev. 8122/Q6
,,
1ST✓
·o
0
0
0 0
0
5c. A Grading Permit has been applied for:
PE2
Grading Inspector sign off by:
5d. No Grading Permit required.
MISCELLANEOUS PERMITS
DWG
Date:
6. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way.
A separate Right-of-Way issued by the Engineering Department is required
for the following:
Please complete attached Right-of-Way application form and return to the
Engineering Department together with the requirements on the attached Right-
of-Way checklist, at the time of resubmittal.
Right-of-Way Permit and Pool Building Permit will be issued simultaneously.
7. Remarks
H:IWORO\DOCS\CHKLST\Pool Buikllng Plancheck Cktlst CHK24 Form BE.doc Rev. 8122196
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER C Bola 35 47
ADDRESS o?Lf,;) 6 Lap,:s ::Rd
,
DATE I~ -;;x?--oC::,
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL
(<$10,000.00)
CARLSBAD COMPANY STORES
c.;OOL. Is?)
VILLAGE FAIRE
RETAINING WALL COMPLETE OFFICE BUILDING
OTHER. _________________ _
PLANNER~~~n~rn~b==,~M1/\r.=---o~· ---DATE ld-.;lQ ::d(o
ENGINEER _________ _ DATE __ _
05/21/2007 13:49 85'34969758 Q-lRISTIAN WHEELER EN
'Jtc. ~ ... r n ~
PAGE 02
l • d
?\.a,22.2001
Minioo V111lcyPools
8284 Mirunu R.otd
S1111 Diego, California n .131
Attention: John Chamu
• CHRJSTIAN WHEELER. ENGINEER.ING
Subject: Limited ln'I ~tig:ttioa of .Bmting Ma30nIY Walls,
2428 lApia ·1oad. CWb:ad, Califomia. o\Jwlol¥-
Deujo!\,t!
\f\/\
In accordance with yot r request Arid our pr:opo,al dated M:iy 17, 20(;!7, -we ha-tt ptep:aicd this repon to ptest!!nt me
Goding, of OU'\" hted .'1l'ftstigation of the exiu:i,,g m~onty ~ at the subject residence. The,~ walls are part of m
e,cl.sting pool 11nd spa s·.nicture that we 'Understand ,ns pct.mittcd by the City of Cllrl,bad. The putpo~e of dus
inv~tig,1t\OT.I-, to de::e.rmine the presecce 211d app~11~ spacing or 1emforcing steel in the subject masonry walls.
More spedfically, our f ,ope of suvices hu incl1lded tbe foUowing.
• Pc~.rJ0m1Cd nc-n-destructive testing uRing l\ J ,mes HR-meter to locate the tci.ttfutclng steel within the tubjcct
muonryw:alh
• Obmved tht. vertical tt:inforcing &tcd exposed 11t the bQclt of the w:tll to verify the ~e at three l~tions.
• Ptt:p11ti:d this report describing the 11:sting pex(o.roied and prcsentitlg our fi.n.d.iligs.
It should be noted th2 · our limited invi:stigation included dctcnnining the ptt1e.nce of ,:clnfotcing !l!!el 11.c iclcct
locadoos. The coo.ditb11s obM:toved.11t the tested loation~ 1ru1.y "t may not be repttset:1t1.t.ivc of other ue11., that wtett not
tested. Out scope of t!:rvices did n.ot include :lCl evaluation of tht: ovccaD in!Rgrity of the W2ll, but did rrutke reasootble
efforts to detctminc th: location or the i:cin.f'otd.11g steel in the mbject -11.s.
FINDINGS
The subject ,nasoruy ,:,a]b are in a p11.tio ~ d1:Jt18 the soum side of the spa u the WC$t end of the pooL Thocc
perimetcrwsD.s v;arled &om appro~tely 2' to 4' tall and 2ppetn:d. to be coosttucted of8" X 8" X 16'' (wideh l( heightx
length) concrete muo;uy units. Sill: locaticx,s were opened in the fo:c of the w2l1 on the $Oil side where the reinforcing
s~el bus 111ete visible. All exposed remfor.ciug steel appc=d to be #3 deformed bar. The clearMce of the vcnic~l bus
wM measured .in these m locittions to the bll.ck of tllc Wolil and foWl.d to be bctwcea 2 a11d 3 it,chcs.
492S !\,fcrcury St~·cet + S11n Diego, CA 92111 ♦ s,s-496-9760 .., FAX 85R-496-9758
6218-St,5 (858)
,05/22/2007 13:49
CWB 2070410.1
CHRISTIAN WHEELER EN
May 22, 2fxr7
PAGE 03
The 'Wllllswett te,~d C'.l, both filcer using aJ1mcs HR-meter to de~rminc the spacing of the st.eel b:.n within the rubic<'-t
~alb. '!'bis i, 11 hmd-hdd device thl!t measures the m~etk induction at the surface of tclnforced m2soazy. A change
in the rmgner.ic field o~~urs when t. telnfotciog st:Eel bu is dite~tl.r below the metet. It should be understood tbllt the
HR-meter is a non..de,1:ructivc electto-m11gner.ic dcvic:c Wt m11y not detect 11U of the teinfotcing "eel ,anc;I will not
dlscti~tc betw1:cn tt:inforcirtg $reel or other em~ded steel items.
Based on tbc rerults of ow: te~ting, th.c masomy IWD.s 11~ac-ed tr.> be reinfotced wich. #3 vertic;;u steel bus spaced •t
Rpp.roximately 16" on center. The homo11t:al st~I w:is detected tt 11pprodmatcly 8" and 2'-6" :above thc bottom of the
wall. The: reinfoicing ,,;eel llppcared to exllend acxos, the entite wdl from 5id.c to side and l'Op to bottom.
We tpptcciatc this opp:lrmcity to pwvidc our Mo.teri:al Testing Services. If you have any quesrion.s 11.fter reviewing this
ieport, please led &ee .:o contact rnc at 858--496-9760.
Respectfully rubmittcd,
CHRISTIAN WHEEI.Ell. ENGINEERING
~/1:$;-
Scnior~er
cc: Submitted
6c18-6-t,S (858)