Loading...
HomeMy WebLinkAbout2438 OCEAN ST; ; CB921124; Permit116 > 1 0 BUILDING PERMIT 02/08/93 15:29 Page lof 1 Job Address: 2438 OCEAN ST Suite: Permit Type: RESIDENTAL ADD/ALT Permit No: CB921124 Project No: A9202309 Development No: Parcel No: 203-022-17-00 Lot#: Valuation: 41,415 Construction Type: VN Occupancy Group:R3 Ref erence#: Status: ISSUED Description: 355 SF ADD + 300 SF REMODEL + Applied: 10/20/92 184 SF DECK Apr/Issue: 11/25/92 illS 0 091 1/è2 Appl/Ownr : NIXON, ANGELA AND NICK 714 394-7311 CPR1T 8700 2438 OCEAN STREET CARLSBAD, CA 9208 - *** Fees Co Fees: 19 Adjustments: T Total Fees: 7%)o B 1 la Fee description Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL g Is Enter "Y" for P1 bin Each Plumbing Fixt&re or T a Each Building Sewer' * PLUMBING TOTAL Enter "Y" for Electri\ Enter "Y" for Remodel'\ c * ELECTRICAL TOTAL Enter 'Y' for Mechanical "is Each Install/Reloc Appliance Each Hood/Fireplace * MECHANICAL TOTAL cted & Credits ----------------------- .00 632.00 ue: \ 87.00 363.00 236.00 4.00 I 603.00 / 20.00 Y 7.0/0 35.00 15./S0 15.00 / 70.00 / 10.00 Y / 10.00 1' 20.00 15.00 Y 4.50 4.50 6.50 6.50 26.00 OVL FINSa E CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PERMIT APPLICATION S City of Carlsbad Building Department 2075 Las Palms Dr., Carlsbad, CA 92009 (619) 438-1161 S 1. PIRM1T IYPI A - LI Commercial U New Building U Tenant Improvement B -0 Industrial 0 New Building El Tenant Improvement C - Iff Residential El Apartment 0 Condo 0 Single Family Dwelling 14 Addition/Alteration Duplex 0 Demolition 0 Relocation 0 Mobile Home X Electrical hl Plumbing Mechanical 0 Pool 0 Spa 0 Retaining Wall 0 Solar 0 Other__________ PLAN CHECK NO. EST. vAL__________ PLAN CK DEPOSIT VALID. BY DATE ' k k 'r • 229.o Q ~_ 535 3 FOR OFFICE USE ONLY ,%Uurtsc /3 4i1 7'. DURIU1118 UI )UILC LW. Nearest Cross Street Mztj Vi -1 l)'-i vc— LEGAL DESCRIPTION Lot No. Subdivision Name/Number Unit No. Phase No. CHECK BELOW IF SUBMIIFED: 0 2 Energy Calm X2 Structural Calm 02 Soils Report Dl Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPOSED USE DESCRIPTION OF WORK Alb 3ArAX~ AF7 ,W457j2 'B(.P..O-øisI — Ah b "OF 1ECK 4'tP- ,sia4-SrCt. BV'-c,r, wn SQ. Fr. 9f.tl # OF STORIES , PLUS Vj'p2. )SL WNIM..I 1IJN (ir aitlerent Irom applicant) NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE APPLICANT U WNIRAIUR U MiENI FOR WNTRACIUR 3JWNER U A(iENT FOR OWNER NAME A. ,jIccii') - ADDRESS 2L(37 CITY C24z.L$'(?4.t) - STATE (.4 ZIP CODE CI DAY TELEPHONE 7/ -3 1 NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE b. WNTEACTUR NAME ,J&t.J L ADDRESS CITY STATE ZIP CODE DAY TELEPHONE 73',' STATE LIC. # LICENSE CLASS CITY BUSINESS LIC. # DESKNER NAME1 (orht ñPC4II7(& ADDRESS q7y7 cxs#MtTh. 131 sC'17f_ CITY 2 C41ftJfThC- STATE (4. ZIP CODE DAY TELEPHONE4 ? 3STATE LIC. # 7. WORKERS WMPENSA1I&4 Workers' Compensation Declaration: I hereby atlirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Buildig Inspection Department (Section 3800, Lab. Q. INSURANCE COMPANY A'7c1 f2,,.1 & LI NO. EXPIRATION DATE so as to becoigg subj#Ft t?thorkers' Compensation Laws of California. Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's license Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). E3 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exem~thfr , om,d the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects th plic alty more than five hundred dollars [$500]). SIGNATfJRII ' DATE /e::i—). 0 -,1. Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES ONO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES 0 N IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLUT1ION (X)N11(OL DISTEICF. I hereby aUinn that there is a construction lending agency for the performance Of the work for which this permit is issued (Sec 3097(i) Civil Code). LENDER'S NAME IV02V4& LENDER'S ADDRESS 10. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CrIY IN CONSEQUENCE OF THE GRANTING OF lullS PERMIT. 0511k An OSHA permit is required for excavations over 5,0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at an tilhe after wor commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLICANTS SIGNATURE DATE: WHITE: File YELLOW: Applicant PINK: Finance . CITY OF CARLSBAD INSPECTION REQUEST PERNIT# CB921124 FOR 05/31/94 DESCRIPTION: 355 SF ADD + 300 SF REMODEL + 184 SF DECK TYPE: RAD JOB ADDRESS: 2438 OCEAN ST APPLICANT: NIXON, ANGELA AND NICK CONTRACTOR: OWNER: REMARKS: MW/NICK/720-4271. SPECIAL INSTRUCT: TEMPERED GLASS IN INSPECTOR AREA TP PLANCK# CB921124 0CC GRPR3 CONSTR. TYPE VN STE: LOT: PHONE: 714-394-7311 . PHONE: PHONE: INS PECTO HANDICAP DONE TOTAL TIME: CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 . EL Final Electrical 49 ME Final Mechanical **1c INSPECTION HISTORY ***** DATE DESCRIPTION . ACT INSP COMMENTS 041294 Final Structural CO PD 041294. Final Plumbing . CO' PD 041294 Final Electrical CO PD 041294 Final Mechanical PA PD 042093. Exterior Lath/Drywall AP PD . 041393 Shear Panels/HD's AP PD • 040293 Interior Lath/Drywall AP TP 032993 Rough Combo '. . AP PD 032993. Insulation . AP PD FRAME OK 032693 Rough. Combo AP PD 031893 Roof/Reroof . CO PD 031893 Frame/Steel/Bolting/Welding CO PD . . . . 020293 Frame/Steel/Bolting/Welding PA PD . . 120292 Ftg/Foundation/PierS • AP PD . United States Testing Company, Inc. Engineering & Support Services 3467 Kurtz Street, San Diego, CA 92110 (619) 225-9641 Job No: 01151400 Distributed To: Job Name: NIXON RESIDENCE CITY OF CARLSBAD Address: 2438 OCEAN ST. ENGINEERING DEPARTMENT CITY OF CARLSBAD CARLSBAD, CA 00000 2075 LAS PALMAS DRIVE NICK NIXON CARLSBAD, CA 92009 CH&A CORPORATION Plan Number: Permit: 92-1124 Application: Report No: 9554 Date: December 12, 1992 ENGINEER: S. FRANKUM RCE CA37766 FIELD INSPECTION REPORT REINFORCED CONCRETE DATE OF INSPECTION: 12/02/92 LOCATION OF WORK INSPECTED: 1) Exterior perimeter footing and column footings and exterior grade beam as illustrated by plans. 2) Interior existing footing at living room. Steel was added at owner's request (Inspection was not required). CONTRACTOR: Owner & Ayers Construction SUPPLIER: Palamar Transit Escondido MIX DESIGN NUMBER: 403007 DESIGN STRENGTH: 3000 psi CUBIC YARDS PLACED: 11.0 PLACEMENT METHOD: Pump ITEM ACCEPT REJECT I NOTES Placement x 3000 psi requirement is only for exterior grade beam. Reinforcing Steel x Batch Tickets x - Consolidation x Form Clean x SET NUMBER CYLINDERS PER SET SLUMP INCHES AIR PERCENT AIR TEMP TEMPERATURE IF 1 3 31/4" 65 72 THE WORK DESCRIBED ABOVE WAS PERFORMED IN ACCORDANCE WITH THE PROJECT PLANS AND SPEC] INSPECTOR: Richard Mathes NUMBER: 31229 JOB HOURS: 4.0 START TIME: 12:00 STOP TIME: 4:00 THIS REPORT DOES NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO BUILD PER THE PLANS, SPECIFICATIONS AND ALL APPLICABLE CODES. United States Testing Company, Inc. Engineering & Support Services 3467 Kurtz Street, San Diego, CA 92110 (619) 225-9641 Job NO: 01151400 Job Name: NIXON RESIDENCE Address: 2438 OCEAN ST. CARLSBAD, CA 00000 Plan Number: CITY OF CARLSBAD ENGINEERING DEPARTMENT 2075 LAS PALMAS DRIVE CARLSBAD, CA 92009 Permit:92-1124. Application: Distributed To: CITY OF CARLSBAD NICK NIXON CH&A CORPORATION Report No: 113162 Date: January 5, 1993 ENGINEER: S. FRANKU}1 RCE CA37766 CONCRETE COMPRESSION TEST REPORT (TESTED TO ASTN C-39) .....................................................L:::i.::::::::::,1:::::::::.;gu....................... JOB NAME: NIXON RESIDENCE PERMIT 992-1124 LOCATION IN STRUCTURE: EXTERIOR COLUMN FOOTING AND GRADE SEAM CAST DATE: 12-02-92 DESIGN PSI: 3000 MIX DESIGN: 403007 SLUMP: 3k" TIME OF DAY:' 2:25 LOAD#/PLANT CODE: 1/81 TEMPERATURE: 72F UNIT NT. PCF: AIR PERCENT: CYLINDERi__.••-..i AREA, LOAD, LBS. COMPRESSIVE TEST INCHES SQ. INCHES STRENGTH, PSI ire........................................................................... 06399 28 6 28.27 116000 4100 06400 60 6 28.27 DISCARD COMPLIANCE: 28 DAY TEST COMPLIES WITH SPECIFICATIONS ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 5601468 DATE: 11/4f99 JURISDICTION: PLAN CHECK NO: 114 SET: IU PROJECT ADDRESS: Qcr PROJECT NAME: e SJURISDICTION) []FILE COPY DUPS DDESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the .jurisdic: ion's building codes. The plans transmitted herewith will substantially comply E with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies U identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. fl The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. fl The applicant's copy of the check list is enclosed for the U jurisdiction to return to the applicant contact person. fl The applicant's copy of the check list has been sent to: ME Esgil staff didnot advise the applicant contact person that plan check has been completed. j Esgil staff did advise applicant that the plan check has been completed. Person contacted:_______________________ Date contacted: Telephone It - D REMARKS: By:1JJ.CtL 1 ,V Enclosures: ESGILCORIORATION DGA 13CII ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) S60-1468. W- P I C A ~NT -1,7t R ~IS D I C flFILE COPY o UPS []DESIGNER DATE: JURISDICTION: PLAN CHECK NO: 9- lI.Q4 SET:. PROJECT ADDRESS:24?j'B 0ceô-c .Sc. PROJECT NAME: tYGi\ eS. Md\ E] The plans transmitted herewith have been corrected where necessary and substantially comply with the .jurisdiction's• building codes. The plans transmitted herewith will, substantially comply with the jurisdiction's building codes. when. minor deficien- cies identified are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be correôted and resubmitted for a complete recheck. do The check list transmitted herewith is for your information. WM The plans are being held at 'Esgil Corp. until corrected plans.are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. IN.The applicant's copy of the check list has been sent to.: A. Lk XOA - €D Oc.eay In Esgil staff did not advise the applicant contact person that plan check has been completed. fl Esgil staff did advise applicant that the plan check has been completed. Person contacted:_______________________ Date contacted: Telephone k_________________ 0 REMARKS: By :VAt{JJ!J(. &JLU?nclosures: . ESGIL CORPORATION E) GA 0 ci CITY Or- CFSLAO fl/i i/ 92.. c.92—(Q.4 1E I' 091 MRIMAIMADMI 1i4 —tt toI r&1w ___s1,IaSi1 -w AT &I MUM - A JIJZ Willow w SO V me I In U&NIMMIYAMA Mal O '-2 ct - pbs jo± O \21 ô+ec*ed. :. ESGIL CORPORATION 9320 CHESAPEAKE.DR., SUITE 208 SAN DIEGO, CA 92123 (619)560.1468 DATE: o/Q.9/92 JURISDICTION: CARLSBAD - PLAN CHECK NO: - 112-4 SET: I PROJECT ADDRESS: 456 OceooA .k PROJECT NAME: Md JURISDICTI PLAN CHEC1 FILE COPY UPS DESIGNER E] -The plans transmitted herewith have been corrected where U necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's-building codes when minor deficien- cies identified are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D The Applicant's. copy of the check list is enclosed for the • jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: (UI L ....4147 Oct hjd £*e'L' Oe\s irte / 9.O5(. D Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the ,plan -check has been completed. Person contactedtby Date contacted: Telephone Ir________________ D REMARKS: By:,jj1J(.. JQ Q& AiJ/ Enclosures:____________________ ESGIL CORPORATION DGA E1 CM FORND: PLEASE READ JURISDIC'flON: Cli! OF CARLSBAD Gkn Gyn-Oix, 4141 3iid b1vd k'L' Ocecae CA 9Q-a5(0 pair ADDRESS: 24 2 Oci &4 FLOOR AREA: 2i M&Ai giIES: Two 22' zE PLAN (X)xicrION SHEET - CITY OF CARL BAD STh.E FAMILY AND DUPLEX WELLflS Date plans received by jurisdiction: Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced -by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1991 UBC (eff. 8/14/92) 1991 UPC (eff. 8/14/92) 1990 NEC (eff. 7/1/91) 1991 UMC (eff. 8/14/92) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To soeed um the recheck Process, note on this list (or a copy) where each correction item has been addressed i.e.. plan sheet, specification. etc. Be sure to enclose the marked u1D list when you submit the revised t,lans. Date plans received by Esgil Corporation: to)QJ1192. Date initial plan check completed: (O&9/92 .. By:CUCk Applicant contact person: @[e Gcok\\ Telephone: 94& ?OO NOTE: PAGE NUMBS ARE NOT IN SJ(CE AS PAGES HAVING NO 14S NEThG- CORRECTIONS WERE D1FF). List No. 2, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1991 UBC) PLANS Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, 0Q. Suite #208, San Diego, California 92123, (619) 560-1468. Please make all corrections on the original tracings and submit wo new sets of prints, to: The jurisdiction's building department. Indicate on the Title Sheet of the plans, the f name of the legal owner and name of person responsible for the preparation of the plans. Section 302(a)7. G All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). D'sigried Plans, specifications i-.iu1atiias. shall be by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expirati)n date of license. (California Business and Professions Code). .1 Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Section 302(d). 7. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1991 UBC, UMC and UPC and 1990 NEC. Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minimum slopes. Section 302(d). 9. Indicate distance from property lines to proposed construction. Section 302(d). Or- NEW Z FECX TO WEST Show on the title sheet all structures, pools, / walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included." 4 Clearly show if the lower level is a basement / or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. G On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below or sticky back. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM REQ. IF REMARKS CHECKED SOILS COMPLIANCE PRIOR TO FOUNDATION INSP. STRUCTURAL CONCRETE / tj OVER 2500 PSI V PRESTRESSED ST.. FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASONRY SPRAYED ON FIRE PROOFING PILES/CAISSONS DESIGNER-SPECIFIED OTHER FIRE PROTFZION Exterior walls closer than 3 feet to property / lines shall be one-hour rated construction and have no openings. Table 5-A. 8/5/92 2 LM' Exterior walls closer than 3 feet to a property line shall have 30 inch parapets when the floor area per floor exceeds 1,000 square feet. See Section.1710 for possible exception. 21. Projections, including eaves, may not extend 7 more than 12 inches into the 3 foot setback from the property line. Section 504(b). Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 504(a). / Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 1711. Plastic skylights shall not be installed within / that portion of a roof located within a distance to property line where openings in exterior walls are prohibited or required to be protected. Section 5207 (a) 7. 19. Show locations of permanently wired smoke fiktector with battery backup: a. Inside each bedroom. Exuy EMOtELE) Centrally located in corridor or area giving access to sleeping rooms. C. On each story. In the basement, if part of the dwelling unit. G When sleeping rooms are upstairs, at the upper level in close proximity to the , stair. J In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 1210. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided at existing bedrooms per item 19 above. Section 1210. Habitable rooms, other than, kitchens, shall f contain at least 70 square feet of floor area. At least one room shall have not less than 120 square feet of floor area. Section 1207 (b). No habitable room, other than a kitchen, shall f be less than 710" in any dimension. Section 1207 (c). Sleeping rooms shall have a window or exterior / door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". Section 1204. Easements in dwelling units shall comly with the above (even if not designated as sleeping rooms). Section 1204. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (b). Appears to be deficient in SPtECAFy £Z.E. 4 TVPE OF A—L t&) Uw.s $ Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and minimum is 1.5 so. ft. Section 1205 (c). , .SE. PcOV. $. At least 1/2 of the coon wall must be open / and have an opening not less than 25 sq. ft. nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room. Section 1205 (a). Required windows shall not open into a roofed / porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court. Section 1205 (a). Provide mechanical ventilation capable of f providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Section 1205 (c). Note that the discharge point for exhaust air ( will be at least 3 feet from any opening into the building. Section 1205(c). Ductless fans cannot be used in bathrooms if a / tub or shower is present. Section 1205(c). Show that ceiling height for habitable rooms is a minimum of 71 6". Section 1207 (a). ,/3. Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 710". Section 1207 (a). Dimension on the plans 30" clear width for f water closet compartments and 24" clearance in front of water closet. Section 511 (a). 5/22/92 3 Show safety glazing in the following Proida 36" high prtctie railing for 35. Show per Section 5406(d): pereheo, baleenies, and open sides of stair a. Where the nearest edge of glazing is landings-. Openings between railings shall be within a 24-inch are of either side of a less than 4". The triangular openings formed door in a closed position (unless there is by the riser, tread and bottom elements of a an intervening wall between the door and guardrail at a stair shall be less than 6". the glazing or if the glazing is 51-0" or Section 1712. SE DE.t 'D'(0/A7 / higher above the walking surface). PrT M r-ft Ri__ Glazing greater than 9 square feet with • the bottom edge less than 18" above the floor and the top edge greater than 36" above the floor (unless the glazing is more than 36" horizontally away from walking surfaces or if' a complying O protective bar is installed). Glazing in shower and tub enclosures (including windows within 5 feet of tub or shower floor). AT 'M1 bkT4 1'J Walls and floors separating units in a duplex / shall be of one-hour fire-resistive construction. Provide details of the assemblies. Section 1202(b). C. Minimum width is 36". Show how guardrail connection details are adequate to support 20 pounds per lineal foot at a right angle to the to rail. Table 23-B. Ur s Ne. S9AcCi o 4x4 Fbst Provide stairway and landing details. Section 3306 (b), (c) and (o). Maximum rise is 7" and minimum run is 11". When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum. Minimum headroom is 61-8" A mezzanine is an intermediate floor and may f not have a floor area exceeding 33 1/3 percent of the total floor area in the room below. The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 44" in height. Section 1717. The loft you show does not comply as a / mezzanine floor and is, by Uniform Building Code definition, a story. Section 1717. Dwellings used for daycare for 7 to 12 children / shall comply with the special requirements in Chapter 12 of Title 24. ITS, STAAYS, AND RAThThGS Floors above the second story shall have not f less than 2 exits. Exceptions: 1. Occupied roofs may have one exit if such occupied areas are less than 500 square feet and located no higher than immediately above the second story. 2. When the third floor within a unit does not exceed 500 sq. ft., only, one exit need be provided. Section 3303(a). Required exit doorways shall be not 'less than / 36" in width and not less than 618" in height. 45. All handrails per Section 3306 (i), shall satisfy the following: Provide handrail for stairways with 4 or more risers. Handrails and handrail extensions shall be 34" to 38" above the nosing of treads. c. The handgrip portion of handrail shall be not less than 1 1/211, nor more than 2" in cross-sectional dimension. I EO1TAIR. ft' Except for stairs serving only one / tenant, handrails shall be extended 12" beyond the top and bottom of the stair. Every stairway landing shall have a / dimension, measured in the direction of travel, at least equal to the stairway width. If a door occurs at the landing, such dimension need not exceed 36 inches. Section 3306 (g), 3304 (j). jv1 An interior door may open at a landing that is I not more than all lower than the floor level, provided the door does not swing over the landing. Section 3304(i). Provide details of winding stairway complying ( with Section 3306 (d): Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from where the treads are narrowest. Maximum rise is 8 inches. C. Minimum width is 36 inches. 9/2/92 4 Provide spiral stairway details, per Section 3306 (f): Minimum run is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9 1/2 inches. Maximum clear opening between risers is 6 inches. C. Minimum headroom is 6 feet 8 inches d. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. Spiral stairways may not be used for required exits when the area served is greater than 400 sq.. ft. Section 3306 (f). -. Provide I.C.B.0. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. Exterior stairways shall not project into the 3 / foot setback from the property lines. Section 3306 (m).. - The walls and soffits of the enclosed usable / space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (1). 4'. Within units, show that corridors have a f minimum width of 36 inches. Section 3305 (b). ROOFDG X. Specify roof slope. Roof slope is not adequate for roof type /' specified. Table 32-B, D and E. DECJC. 57. Specify roof-Amaterial and application. Chapter 32. Provide skylight details to show compliance with Sections 3401 and 5207 or provide I.C.B.0. approval number. fr1 Plastic skylights must be separated from each f other by at least 4 feet, unless they are over the same room and their combined area does not exceed 100 square feet (or 200 square feet if the plastic is a "CCI" material). Section 5207 (a) 6. Show attic ventilation. Minimum vent area is 1 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). - AND MASONRY Provide fireplace construction details or note construction to be per attached fireplace Standard drawing. Chapter 37. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)1 and Section 2515 (a). Show ties, #9 wire in horizontal joints, etc. /6- Show height and construction details of all concrete and masonry walls. Chapters 24 and 26. Show floor and roof connections to masonry and ( concrete walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. / Show a minimum 2" air space and flashing between planter and building walls. Section 2516 (c) 7. GARAGE AND CARPORTS Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (d). All elements supporting floor above garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the garage side. Section 503 (b) Show a self-closing door, either 1-3/8" solid core or a listed 20-minute assembly, for openings between garage and dwelling. Section 503 (d). Specify I.C.B.0. or U.L. approval number for DEJ&. ,. roof materials not covered in U.B.C., a g tile, etc. Section 107. / 59. Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a) and Section 2305 (f). 'L#1)$ —St 11 11 2." Ft ROOF 'D.CIL G Show roofydrains and overflows. Section 3207. 5/22/92 .5 7J. Garages are not permitted to open into a room / used for sleeping purposes. Section 1104. 7/ An occupancy separation is not required between 7 carport and residence, provided the carport is open on two or more sides and has no enclosed uses above. Section 503 (a) Exception 3. Show garage framing sections, size of header / over garage opening, lateral cross bracing at plate line, method bracing garage front and holddowns if required. Chapter 23. NOTE: Maximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table 25-I. Doors may open into the garage only if the / floor, or landing in the garage is not more than one inch lower than the door threshold. Section 3304 (i). Provide an 18" raised platform for any FAU, / water heater, or other device in the garage which may generate a flame or spark. U?IC Section 508, UPC Section 1310 (a). FOUNDATION ,cuuijcvrS Per soils report, note on the plan the soils classification, whether or not the soil is expansive and the allowable bearing value. Section 2905 (c). The foundation plan does not comply with the 7 soils report recommendations for this project. Please review the report and modify design, notes and details as required to show compliance:__________________________________ Provide notes on the foundation plan listing / the soils report recommendation for foundations, slab and building pad preparation. pi. The soils engineer recommended that he/she / review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: The building pad was prepared in accordance with the soils report, The utility, trenches have been properly backfilled and compacted, and The foundation excavations comply with the intent of the soils report". Provide a letter from the soils engineer / confirming that the foundation plan, grading plan and specifications have been reviewed and 'that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). Show height of all foundation walls. Chapter 23. Show height of retained earth on all foundation walls. Chapter 23. If cut or fill slopes exist, show distance from foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. 85. Note on plans that wood shall be 6" minimum above finish grade. Section 2907 (a). 'SEE I''/P1 (D-6 Note on plans' that surface water will drain away from building and show drainage pattern and key elevations. Section 2905 (f). Dimension foundation per U.B.C. Table 29A: Floors Footing Supported* Stemwall Width Depth Thickness 1 6" 12" 12" 6" 2 8" 15" 18" 7" 3 10" 18" 24" 8" Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. fi€ Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. Show foundation bolt size and spacing. I Section 2907 (f). Specify size, I.C.B.0. number and manufacturer f of power driven pins and expansion anchors. Show edge, end distances and spacing. Section 302 (d). If required, show size, embedment and location / of hold down anchors on foundation plan. Section 302 (d). If hold downs are required, note on plan that I hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 1. /9 Show adequate footings under all bearing walls and shear walls. Section 2907 (b). 5/22/92 6 Show on the plans stepped footings for slopes / steeper than 1:10. Section 2907 (c). Show minimum 18" clearance from grade to / bottom of floor joists and minimum 12" clearance to bottom of girders. Section 2516 (c) 2. Show pier size, spacing and depth into ( undisturbed soil. Table 29-A. Show minimum underfloor access of 18" x 24". ' Section 2516 (c)2. - Show minimum underfloor ventilation equal to 1 / sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to corners as practicable and shall provide cross ventilation. on at least two approximately opposite sides. Section 2516 (c) 6. - FRAMING Show wall bracing. Every exterior wood stud / wall and main cross-stud partition shall be braced at each end at least every 25 feet of length with 1 x 4 diagonal let-in braces or equivalent. Section 2517 (g) 3, Table 25-V. In 2-story buildings, shear panels at the first story (at least 48 inches in width) shall be located at each end or as near thereto as possible and comprise at least 25 percent of the linear length of the wall, or provide design. Section 2517(g)3, Table 25-V. Note cross bridging or blocking. Floor joists 7 and rafters 12" or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held inline. Sec. 2506 (h). ø. Show blocking at ends and at supports of floor 7 joists, rafters and trusses at exterior walls. Section 2517 (d) 3, 2517 (h) 7. Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist. Section 2517 (d) 5. Show rafter ties. Rafter ties shall be spaced 7 not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 (h)5. Show rafter purlin braces to be not less than 7 45 degrees to the horizontal. Section 2517 (h) 6. - p(. Show double top plate with minimum 48" lap splice. Section 2517 (g) 2. Show nailing will be in compliance with Table f 25-Q. Show or note fire blocks at the following locations per Section 2516 (f): In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals both vertical and horizontal; At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; C. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and inline with the run of stairs if the walls under the stairs are unfinished; In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials; and At openings between attic spaces and chimney chases for factory-built chimneys. y. In duplexes, draft stops shall be provided in floor-ceiling assemblies and attics in line with walls separating units and separating units from common areas. Section 2516(f)4. Show stud size and spacing. Maximum allowable f stud heights: Bearing wall: 2 x4 and 2 x 6 max. 101; Non-bearing: 2 x 4 max. 141, 2 x 6 max. 201. Table 25-R-3. J4. Studs supporting two floors, a roof and 7 ceiling must be 3 x 4 or 2 x 6 at 16" 0-c. Table 25-R-3. 1)1'. Note on A.I.T.C. Certificate of Compliance for I glued laminated wood members shall be given to the building inspector prior to installation. Section 2505. Detail all post-to-beam and post-to-footing /3. connections and reference the detail to the plan. Section 2516 (m). 1)41 Detail shear transfer connections, including f roof and floor diaphragms, to shear walls. 1 Section 2513. 5/22/92 . 7 l)4 Specify nail size and spacing for all shear f walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. [Tables 25 I, J, IC and Section 4714 (d)3. Provide truss details and truss calculations / for this project. Specify truss identification numbers on the plans. 1. Show 1/2" minimum clearance between top plate I of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). Provide roof framing plan and floor framing plan. Section 302 (d). 1 . Provide framing sections through •• Section 302 (4). Specify all header sizes, for opening over 4' f wide. Section 2517 (g) 5. Provide calculations for main vertical and I' horizontal framing members and post footings. Section 302 (b). / 2. Provide calculations for lateral loads, shear panels, shear transfer and related. Section 302 (b). In Seismic Zones 3 and 4, the allowable shear /3. wall values for drywall in Table 47-I must be reduced 50 percent when considering earthquake loads. This does not apply to wind loads. Footnote 1. )(4. Show on the plans all structural requirements / developed in the structural calculations. Section 302 (d). (See comments below or at end.) /5- Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. Individual concrete or masonry piers shall /6- project at least 8 inches above exposed ground unless the columns or posts, which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. i,zl'. Show location of attic access with a minimum I size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 3205(a). A Show location of attic access with minimum size 22" x 30". Section 3205. Detail truss layout for 30" x 30" attic A access, if required for equipment in the attic, and detail 30" x 30" clearance through truss webs. ,.x(o. Specify plywood and/or particle board thickness, grade and panel span rating. Table 25-S. Show plywood sheathing over exposed eaves, or I other weather exposed areas, is "bonded with exterior glue." Plywood used for exterior wall covering shall be the exterior type. Section 2516 (i), 2516(g)3. When roof pitch is less than 3:12, design /2. ridge as a beam. Section 2517 (h). Ridges, hips, and valleys shall be at least / one size larger than supported rafters. Section 2517 (h) 3. )4'4. In open beam construction, provide strap ties / across the beams at the ridge support. Section 2501 (b). If foundation-cripple wall studs are less ' than 14" high, framing shall be solid blocking, or sheathed with plywood. Section 2517 (g) 4. Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. 137. Note on the plans that "all weather-exposed surfaces shall have 'a weather-resistive barrier to protect the interior wall covering and that exterior. openings shall be flashed in such a manner as to make them weatherproof". Section 1708. MECHANICAL (UNIFORM MECHANICAL a)DE) All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. 5/22/92 8 l8 Show the size, location and type of all 7 heating and cooling appliances or systems. l)4 Every dwelling unit shall be provided with 7 heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 1212. Note on the plans that the FAU closet or 7 alcove must be 12 inches wider than the furnace or furnaces being installed. UMC Section 704. /41. - Show minimum 30" deep unobstructed working /2. space in front of furnace. Section 505, UMC. Furnace shall not be installed in any bedroom, bathroom or in a closet or confined space with access, only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. Show source of combustion air to furnace, per /3. chapter 6, UMC. Show access to the attic containing. equipment 7 to be minimum 30 inches by 30 inches. The opening may be 22 inches by 30 inches if the equipment can be removed through such opening. Section 708 UMC. /5. Note that passageway to the attic furnace shall be 'unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length through the attic. Section 708 UMC. /6- Show permanent electrical outlet and lighting fixture controlled by a switch for furnace located in. attic or underfloor space. Section 708 & 709 UMC. /7. Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace. )4(8. Show I.C.B.O. approval number for prefab I fireplace. Show height of chimney above roof / per I.C.B.0. approval or Table 37-B. Note on the plans that approved spark I arrestors shall be installed on all chimneys. Section 3703(h) /0.Note on plan: Gas vents and non-combustible piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (c). Provide dryer vent to outside. UMC, Section f 1903. All wiring shall comply with the National Electrical. Code. 1)4. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub- panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. Show on the plan that receptacle outlets / comply with 1990 NEC Art. 210-52(a), which reads as follows: In every kitchen, dining room, parlor, library, den, sunroom, bedroom, recreation room, or similar rooms or area of dwelling units, receptacle outlets shall be installed so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from an outlet in that space, including any wall space 2 feet or more in width and the wall space occupied by fixed panels in exterior walls, but excluding sliding'panels in exterior walls. The wall space fforded by fixed room dividers, such as free-standing bar-type counters, shall be included in the 6-foot measurement. Dwelling Unit Receptacle Outlets 210.52(a) .1 SIidng Panels at Doors -e f_ L.,•....4....4•.._4 l-4411 8/5/92 9 id Show on the plan that countertop receptacle outlets comply with 1990 NEC Art. 210-52(c), ' which reads as follows: In kitchens and-dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches. Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space. Island and peninsular countertops 12 inches or wider shall have at least one receptacle for each four feet of counter top. Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces. Receptacles rendered inaccessible by appliances fastened in place or appliances occupying dedicated space shall not be considered as these required outlets. Dwelling Unit Receptacle Outlets Hallways 210.52(h) OR Ban . r-K Z; C- flT A-, q e.3 ' LA ,i ,c.c Dwelling Unit Re acle Outlets Counter Tops 210.52q 1)1. Show on the plan that receptacle outlets in / hallways comply with 1990 NEC Art. 210-52(h), which reads as follows: For hallways of 10 feet or more in length at least one receptacle outlet shall be required. As used in this subsection the ball length shall be considered the length along the centerline of the ball without, passing through a doorway. Show on the plan that lighting outlets in /b. dwelling units comply with 1990 NEC Art. 210- 70(a) and (c), which read as follows: (a) Dwelling Unit(s). At least one wall switch-controlled lighting outlet shall be installed in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at outdoor entrances or exits. (FPN): A vehicle door in an attached garage is not considered as an outdoor entrance. At least one lighting outlet controlled by a light switch located at the point of entry to the attic, underfloor space, utility room,, and basement shall be installed only where these spaces are used for storage or contain equipment requiring servicing. The lighting outlet shall be provided at or near the equipment requiring servicing. Where lighting outlets are installed according to (a) above in interior stairways, there shall be a wall switch at each floor level to control the lighting outlet where the difference between floor levels is six steps or more. Exception No. 1: In habitable rooms, other than kitchens and bathrooms, or more receptacles controlled by a wall switch shall be permitted in lieu of lighting outlets. Exception No. 2: In hallways, stairways, and at outdoor entrances remote, central, or automatic control of lighting shall be permitted. 8/6/92 . .. . . 10 (c) Other Locations. At least one wall switch- controlled lighting outlet shall be installed at or near heating, air-conditioning, and refrigeration equipment in attics or underfloor spaces. The light switch shall be located at the point of entry to the attic or underfloor space. G Show on the plan that ground-fault circuit- interrupter protection complies with 1990 NEC Art. 210-8, which reads as follows: Dwelling Units. All 125-volt, sing1e-phase, 15- and 20- ampere receptacles installed in bathrooms shall have ground-fault circuit-interrupter projection for personnel. ()"J' All 125-volt, single-phase, 15- or 20- 4mpere receptacles installed -in garages shall have ground-fault circuit- interrupter protection for personnel. Exception No. 1 to (a)(2): Receptacles which are not readily accessible. Exception No. 2 to (a)(2): Receptacles for appliances occupying dedicated space which are cord- and plug-connected in accordance with Section 400-7(a)(6), (a)(7), or (a)(8). Receptacles installed under Exceptions to Section 210-8(a)(2) shall not be conside:ed as meeting the, requirements of Section 210-52(g). All 125-volt, single-phase, 15- and 20- fampere receptacles installed outdoors where there is direct grade level access to the dwelling unit and to the receptacles shall have ground-fault circuit-interrupter protection for personnel. (FPN): See Section 215-9 for feeder protection. For the purposes of this section, "direct grade level access" is defined as being located not more than 6 feet, 6 inches (1.98m) above grade level and being readily accessible. All 125-volt, single-phase, 15- and 20- 4mpere receptacles, installed in crawl spaces at 1or below grade level and in unfinished basements shall have ground-fault circuit- interrupter protection for personnel. Exception No. 1: A single receptacle supplied by a dedicated branch circuit which is located and identified for specific use by a cord- and plug-connected appliance, such as a refrigerator or freezer.. Exception No. 2: The laundry circuit as required by Sections 210-52(f) and 220-4(c). Exception No. 3: A single receptacle supplying a permanently installed sump pump. All 125-volt, single-phase, 15- and 20- ampere receptacles installed within 6 feet of a kitchen sink to serve counter top surfaces shall have ground-fault circuit-interrupter protection for personnel. (FPN): The intent of this subsection is to permit the exemption of receptacles which are located specifically for appliances such 'as refrigerators and freezers from ground-fault circuit-interrupter protection for personnel. GFCI Protection for Personnel Receptacles in the Vicinity of Kitchen Sinks 210-8(e)(5) i-6-----I l-6-----I I r, IReLI GFCI ,L__4 GFCI GFCI C - 6 r I ee GFCI GFCI Kitchen 4. Show water heater size, type and location on ( plans. UPC, Section 1301. 'Note on the plans that "combustion air for ( fuel burning water heaters will be provided in accordance with the Uniform Plumbing Code". )(0. Fuel combustion water heater shall not be ( ' installed in clothes closets, in a bath or bedroom, or in a closet opening into bath or bedroom. UPC, Section 1309. 1ftf Provide adequate barrier to protect water 7 heater from vehicle damage. An 18" platform for the water heater does not satisfy this requirement. UPC, Section 1310. 8/6/92 Show T and P valve on water heater and show 1. route of discharge line to exterior. UPC, Section 1007 (e). Show that water heater is adequately braced to / resist seismic forces. UPC, Section 1310. Show shower stall can accommodate a 30" circle /4- and has a minimum floor area of 1,024 sq. in. UPC 909 (d). 4. Provide clothes washer hook-up for each unit. I Title 24, Part 3. EDvalves, New water closets and associated flushometer if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2, and urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard A11219.2 'H & S Code, Section 17921.3(b). WISE ThSULAIION (DUPLEXES) 30f. Show details of duplex common (party) walls and floor/ceiling assemblies to achieve a Sound Transmission Class (SIC) rating in walls of 50 decibels and an Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibels. Title 24. i4. Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or. heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 24. Provide insulation in walls and ceiling to achieve SIC of 50 between garage and living area. if garage use is not controlled by resident. Title 24. p(. All energy items shown on the plans must be in F agreement with the information shown on the properly completed Form CF-lR. 173. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Enemy Conservation Requirements". J4. Show the make, model and efficiency of the f space heating (or cooling) system and provide heat loss calculations if the output exceeds 45,000 BTU/Hr. For room additions, show that the glazing area f of the addition does not exceed 16% of the newly-conditioned floor area, plus glazing removed or relocated due to the addition. Provide fluorescent general lighting in kitchen(s) per CAC, Title 24, 2-5352(3). CARLSBAD S.F.D. & DUPLEX SUPPLDIENZ Energy conservation design should be for Zone /7. 7. Floor drains must have auto-prime (city f policy). For gas piping under slabs that serve kitchen island cooktops, see the attached Policy 91-46 for special sleeve and clean-out requirements. Note exhaust fans cannot be ductless type / (city policy). J.. New residential units must be pre-plumbed for f future solar water heating. Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). Incorporate the waterproofing details, on the I attached Policy 80-8, where interior living space occurs below grade at the masonry wall(s). 14. Note "two 3/4" copper pipes must be installed f to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 170. Provide plans, calculations and worksheets to 8093). show compliance with current energy standaxds. C2-A 41a MUST INCLUDE TVI * At,DrflO ?.) All piping for present or future solar water Sand The regulations require a properly completed / heating must be insulated when in areas that properly signed Form CF-IR to be either are not heated or cooled by mechanical means imprinted on the plans, taped to the plans or (city policy). cky backed" on the plans, •to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. 8/11/92 8/11/92 13 ) Show on the Title Sheet on the plans, the I information required by the attached Developmental Services Sheet 112383. All new residential buildings, including /' additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and 1000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the plans. - Heavy timber framing, minimum 6" x 10" beams and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). All structures require a Class B roof covering, except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't apply. City Ordinance 9792 requires two parking f spaces/unit with clear area of 20'x2O' i.e. no washing machines, etc. Show compliance. Only tank-type water closets that use an average of 1.6 gallons of water per flush or less, and urinals and associated flushometer valves, that use an average of 1 gallon of water per flush or less shall -be installed in new construction. These provisions shall apply to existing buildings only when toilets are being replaced in existing bathrooms or installed in new bathrooms. Please see additional corrections, or remarks, on the following page. Olist To speed up the recheck process, note on this (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 193. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list?. Please check. The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact_________________ C'nuck eey\c\ at Esgil Corporation. If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las Palmas Dr., telephone 619/438-1161. Thank you. Enclosures: Yes __No Datei *~ Jurisdiction Ccirkbor( Prepared byi ci Bldg. Dept. VALUATION AND PLAN CHECK FEE E3 Esgil PLAN CHECK NO. _92-1t4 BUILDING ADDRESS _24?i Ocea APPLICANT/CONTACT 1e--A BUILDING OCCUPANCY ________________ TYPE .QF CONSTRUCTION PHONE NO. 945-3(,Oo DESIGNER PHONE_____________ CONTRACTOR PHONE___________ BUILDING PORTION BUILDING AREA VALUATION MULTIPLIER VALUE LAU3 Ls 74u12 - nee (C- lSoo Air Conditioninz Commercial Residential - Res. or Comm. Fire _Sprinklers Total Value 1 'c4o.s Building Permit Fee Plan Check Fee $ $ 10 t, E3 C 0 H tl C N T S: \)&t (1eA &s ci T. 1, SHEET __L OF I. 12/87 1Ov LVTi4 M4P.1'722.. City of Carlsbad BUILDING PLANCHECK CHECKLIST DATE: 2.8 cxrr 92.. PLANCHECK N0Q892-1 i24 BUILDING ADDRESS: 2-438 cX.'E1"..J T PROJECT DESCRIPTION: POR. ADD. ASSESSOR's PARCEL NUMBER: 203 022. 17 EST. VALUE___________ ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. DENIAL Please see the attached report of deficiencies marked with;9 Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: S. 2H EbELL Date: 28 rr92.. By:__ Date:________ By: Date:_________ ATTACHMENTS O Dedication Application O Dedication Checklist o Improvement Application O Improvement Checklist O Future Improvement Agreement NAME: ADDRESS: CONTACT PERSON PHONE: P:docs\ch1ds1\bp0001.frm . ' . REV 6/5/92 2075 Las Palmas Dr. • Carlsbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894 BUILDING PLANCHECK CHECKLIST SITE PLAN 1 s 2nd,/ 3rd./ DD 1; Provide a fully dimensioned site plan drawn to scale. Show: North Arrow D Property Unes Easements Existing & Proposed Structures E. Easements Existing Street Improvements F. Right-of-Way Width & Adjacent Streets I1 0 2. Show on site plan: - ~Ap~r~!~a~g C, Existing Topography B. Existi&Proposed Slopes 121' 0 0 3. Show on a section drawing or include a note stating that there is a minimum of 6" difference between the finished floor and the finished grade elevation adjacent to the structure. .)2L Id 0 4Cinciud'e ote: "Surface water to be directed away from the building foundation at a 2% or no less than 5' or 2/3 the distance to the property line (whichever is less)." UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.). 521" 0 0 5. Include on title sheet Site address Assessor's Parcel Number C.. Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office; etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION P:docs\chkIst\bp0001Jrm Page 1 of 4 REV 6/5/92 BUILDING PLANCHECK CHECKLIST• DISCRETIONARY APPROVAL COMPLIANCE 1.,,.t./ 2nd./ 3rd./ 0 0 0 6. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by: Date:_________________ DEDICATION REQUIREMENTS 0' 0 0 7. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for ' remodels with a value at or exceeding $______________ -pursuant to Code Section 18.40.030. Dedication required as follows: Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by Date:__________ IMPROVEMENT REQUIREMENTS o o 0 8a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. Public improvements required as follows: Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the, requirements on the attached checkliSt for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements.. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans signed by: Date: P:\docschkI.rtbpOOO1.frm - Page 2 of 4 ' . . REV 6/5/92 BUILDING PLANCHECK CHECKLIST 1 SW 2fldv' 3rdf 0 0 0 8b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $_ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to iésuance of a Building Permit. Future public improvements required as follows:_____________________________ O 0 0 8c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. Future Improvement Agreement completed by: Date:__________________ 0 0 8d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. O 0 0 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). O 0 0 9b. Grading Permit required. A separate grading plan prepared by a registered Civii Engineer must be Submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: 0 9c. No Grading Permit required. BUILDING PLANCHECK CHECKLIST P:\docs\chk19t\bp0001.frm Page 3 of 4 REV 6/5/92 1 SW 2nd/ 3rd/ DOD MISCELLANEOUS PERMITS A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: Street improvements, trees, driveways. A separate Right-of-Way permit issued by the Engineering Department is required for the following: Please complete attached Right-of-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the time of resubmittal. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. O 0 0 12. INDUSTRIAL WASTE PERMIT is required. Applicant' must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. • Industrial waste permit accepted by:• • Date: P:\doc8\chld9t\bp0001.lrm Page 4014 REV 6/5/92 CALCULATIONS WORKSHEET EDU CALCULATIONS: EDU's: ADT CALCULATIONS: ADT's: N/14 FEES REQUIRED: WITHIN CFD: YES (NO BRIDGE & THOROUGHFARE FEE, REDUCED TRAFFIC IMPACT FEE) ONO 1. PARK-IN-LIEU FEE PARK AREA: FEE/UNIT:_________ 2.TRAFFIC IMPACT FEE ADT's: FEE/ADT: BRIDGE AND THOROUGHFARE FEE ADT's: FEE/ADT:____________ FACILITIES MANAGEMENT FEE ZONE: FEE/EDU:_________ PUBLIC FACILITIES FEE SEWER FEES PERMIT No. EDU's: FEE/EDU:_________ BENEFIT AREA: FEE: 0 7. SEWER LATERAL REQUIRED (2,500 DEPOSIT) REMARKS: P:\docschkM\bpOOO1.frm REV 6/5/92 PLANNING CHECKLIST Plan Check No. CBI?"?-/lZ'fAddress 2c/ lo OCi) Sr 1 Planner VAN LYNCH Phone 438-1161 ext. 4325 14 (Name) rtL,L APN: 20O'17 Type of Project and Use &0 mu.-. a,mJ Zone 12.3 Facilities Management Zone / >S. Legend Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified [?Jii 0 Environmental Review Required: YES - NO TYPE______ DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: YES - NO 2 TYPE APPROVAL/RESO. NO. DATE: PROJECT NO. OTHER RELATED CASES: Cornj,liance with conditions of approval? If not, state conditions which require action. Conditions of Approval . California Coastal Commission Permit Required: YES NO DATE OF APPROVAL: b-'7 -Z6 , San DiegoCoast'District, 3111 Camino Del Rio North, Suite 200, San Diego, CA 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Landscape Plan Required: YES NO See attached submittal requirements for landscape plans Site Plan: 0 1. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing sireet improvements, right-of-way width and dimensioned setbacks. 0 2. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. (2(0 Cl 3. Provide legal description of property. 19/0 '0 4. Provide assessor's parcel number. Zoning: M /C3 C 1 1. Setbacks: . 17W AA' 14 Front: Required 2.0 Shown 1 Int. Side: Required ID' Shown G .3' Street Side: • -Required - Shown - Rear: Required /0' Shown / / 0 2. Lot coverage: Required (4'09 Shown 2c 0 3. Height: Required 30' Shown Z 7" 0 4. Parking: Spaces Required 2- Shown - Guest Spaces Required Shown O 0 Additional Comments 1'~z'v 7k-i CItt.I'F CoA S,701-Comm, c 'o d 1ciit- Al. 7AL. Z)gxU.oP 1,ti èN T /J A) £ "I o4 46VOVS,65. OK TO ISSUE AND END APPROVAL INTO COMPUTER V DATE PLNCK.FRM STATE OF CALIFORNIA—THE RESOURCES AGENCY PETE WILSON, Governor CALIFORNIA COASTAL COMMISSION SAN DIEGO COAST AREA 3111 CAMINO DEL RIO NORTH, SUITE 200 SAN DIEGO, CA 92108-1725 619) EXEMPTION LETTER 521-8036 DATE: kiti'- c2 (Q IF 2_- NAME: _________________________________ This is to certify that this location and/or proposed project ha s b e e n reviewed by the staff of the Coastal Commission. A co a s t a l d e v e l o p m e n t p e r m i t is not necessary for the reasons checked below. The site is not located within the coastal zone as esta b l i s h e d b y t h e California Coastal Act of 1976, as amended. -The proposed development is included in Categorical Exclusion N o . adopted by the California Coastal Commission. The propósed development is judged to be repair or maint e n a n c e a c t i v i t y not resulting in an addition to or enlargement or expans i o n o f t h e o b j e c t of such activities (Section 30610(d) of Coastal Act). ZThe proposed development is an improvement to an existi n g s i n g l e f a m i l y residence (Section 30610(c) of the Coastal Act) and not loca t e d i n t h e area between the sea and the first public road or within 30 0 f e e t o f t h e inland extent of any beach (whichever is greater) (Secti o n 1 3 2 5 0 ( b ) ( 4 ) o f 14 Cal. Admin. Code. The proposed development is-an improvement to an existing s i n g l e f a m i l y - residence and is located in the area between the sea and thef i r s t p u b l i c -- road or withi-n 300 feet of the inland extent of any beach -(w h i c h e v e r i s - greater) but is not a) an increase of 10% or more of interna l f l o o r a r e a , - - b) an increase in height over 10%, or c) a significant-non— a t t a c h e d - structure (-Sections 30610(a) of Coastal Act and Section 132 5 0 ( b ) ( 4 ) o f Administrative Regulations). (OVER) Page 2 The proposed development is an interior modification to an existing use with no change in the density or intensity of use (Section 30106 of Coastal Act). The proposed development involves the installation, testing.and placement in service of a necessary utility connection between an existing service facility and development approved in accordance with coastal development permit requirements, pursuant to Coastal Act Section 30610(f). The proposed development is an improvement to a structure other than a single family residence or public works facility and is not subject to a permit requirement (Section 13253 of Administrative Regulations). The proposed development ,is the rebuilding of a structure, other than a public worksfaciltty,de'stroyed -by-natural disaster. The replacement conforms to all of the, requirements of Coastal Act Section 30610(g). Other: Please be advised that only the project described. above is exempt from the permit requirements of the Coastal Act. Any change in the project may cause it to lose its exempt status. This certification is based on information provided by the recipient of this letter. If, at a later date, this information is found to be incorrect or incomplete, this letter will become invalid, and any development occurring at that time must cease until a coastal development permit is obtained. Truly yours, 6630A