Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2446 Mica Rd; ; CBR2019-2848; Permit
PERMIT REPORT Print Date: 05/11/2020 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Bathrooms: Project Title: 2446 Mica Rd BLDG-Residential 2132700600 $ 9,200.00 Residential Permit Work Class: Cogen Lot#: Project#: Construction Type Orig. Plan Check#: Plan Check#: Description: LAFLEUR: 7.59 KW ROOF MOUNT PV SYSTEM, 23 MODS, NO UPGRADE FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Owner: DWAYNE W LAFLEUR 2446 Mica Rd CARLSBAD,CA 92009 Total Fees: $ 197.63 Total Payments To Date : $ 197.63 (City of Carlsbad Permit No: CBR2019-2848 Status: Applied: Issued: Closed -Expired 10/09/2019 10/09/2019 PermitFinal Close Out: Inspector: TAlva Final Inspection: Contractor: G C ELECTRIC SOLAR Po Box 910413 San Diego, CA 92191-0413 858-999-3929 Balance Due: AMOUNT $114.96 $80.47 $1.00 $1.20 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees /exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division EXPIRED PERMIT PERMIT HAS EXPIRED IN ACCORDANCE WITH C.B.C. SECTION 106.4.4 AS AMENDED BY C.M.C.18.04.~30 DATE 'j, II. J..o SIGNATURE per .J C/':,uVI . 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Page 1 of 1 {cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Est. Value PC Deposit --------- Date _,/...,~,_r_7_,__-~/~9 __ Job Address z ttl-\ <e K \C'.-~ 52.oad Suite: _____ APN: __________ _ CT/Project#: _________________ Lot#:, ___ _ Fire Sprinklers: yes!€} Air Conditioning: yes/@ Electrical Panel Upgrade: yes/ t) BRIEF DESCRIPTION OF WORK: ~IZ=of:~~\:1-'-'o'""'D"",J\...,_.\-"--'S"""-"o'""\a="''----------------- 0 Addition/New: ______ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ D Remodel: SF of affected area -----Is the area a conversion or change of use ? Yes/ No Additional Gas or Electrical Features? □ Pool/Spa: ____ SF ------------- □ Solar: 7 .S"\ KW, 7, 3-Modules, Mounted~round , Tilt:~/ No, RMA: Yes /4::9 Battery: Yes/~ Panel Upgrade: Yes I@ D Reroof: -------------------------------------- □ Plumbing/Mechanical/Electrical Only: ________________________ _ D Other: ____________________________________ _ APPLICANT {PRIMARY CONTAC!J. PROPERTY OWNER Name:G c., £\e.c:\:ric '::>o\av: Name: '.I)\-J4j-/\e.., lz-q(\e-v✓ Address: 7'.:'.l<;:Q S,hie,dW) fl11S? ~\o'I Address:_'Z_-"l'-'l'--'~'---'M.....,_,1"-c==-.c.~--'-'--------~- City: ~ D•=0 State: (A Zip: °1"2 1'2 V City:Cou:: \:,b:,d State: C(\ Zip: °lz oo"I Phone:~~ ]"]Q -?;, 5 \\ Phone: __________________ _ Email: ~"".to @u-,,c•-59£ .Gort" Email: ____________________ _ DESIGN PROFESSIONAL Name: _________________ _ Address: ________________ _ City: _______ State: __ ~Zip: ___ _ Phone: _________________ _ Email: ------------------ Architect State License: ___________ _ ,c=-,:?olgv ;)v~ #\ooi '~~Zip: 9,. Cl & (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca,gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Qtl have and will maintain worker's compensation, as required by Section 3700 ofthe Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: ;i±:P<J e C dW\,2'?v"S;0-+ \ ai\, Policy No. °I \'oGf'l ;2)'$ Expiration Date: '7/1eo / )0"2..b □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, Interest and attorney's fees. CONTRACTOR SIGNATURE: -,.'~"--+-.. ""'4~"""""4~✓"-lf-----------QAGENT DATE: ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section ________ ,Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: __________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY, IF ANY: l hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ______________________ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over S'O' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT SIGNATURE: ____________________ DATE: _______ _ 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of2 Email: Building@carlsbadca.gov Rev. 06/18 February 11, 2020 DWAYNE LAFLEUR 2446 MICA RD CARLSBAD, CA 92009 RE: BUILDING PERMIT EXPIRATION PERMIT TYPE: BLDG-Residential, Cogen {'city of Carlsbad PERMIT NUMBER: CBR2019-2848 ISSUE DATE: 10/09/2019 ADDRESS: 2446 Mica Rd Carlsbad, Ca 92009-1733 Our records indicate that your building permit will expire by limitation of time on 04/21/2020. 18.04.030 section 105.S amended -Expiration: Every permit issued by the Building Official under the provisions of this code shall expire by limitation and beoome null and void if the building or work authorized by such permit is not commenced within 180 calendar days from the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 calendar days, or if the building or work authorized by such permit exceeds three calendar years from the issuance date of the permit. Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 calendar days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit. Before such work can be recommenced, a new permit shall be obtained to do so, and the fee therefore shall be one half the amount required for a new pem1it for such work, and provided that no changes have been made or wilt be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new permit fee. Any permittee holding an unexpired permit may apply for an extension of time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons. Please check below indicating your intentions and return this letter to us. D Project abandoned. A new permit will be obtained prior to commencing work. D Permit 180 day extension request, with written explanation including phone number and email address. Request wilt not be considered without explanation D Renewa I permit requested. If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725. If you have any questions, please contact the Building Inspection Division at 760-602-2700. Community & Economic Development Building Division I 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY REPORT (CBR2019-2848) Permit Type: BLDG-Residential Application Date: 10/09/2019 Owner: Work Class: Cogen Issue Date: 10/09/2019 Subdivision: Status: Closed -Expired Expiration Date: 04/21/2020 Address: IVR Number: 22339 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 10/24/2019 10/24/2019 BLDG-35 Solar Panel 108602-2019 Checklist Item BLDG-Building Deficiency 10/29/2019 10/29/2019 BLDG-35 Solar Panel May 11, 2020 BLDG-Final Inspection 109010-2019 109011-2019 Cancelled Tony Alvarado COMMENTS Cancelled Tony Alvarado Cancelled Tony Alvarado DWAYNE LAFLEUR 2446 Mica Rd Carlsbad, CA 92009 Reinspection Complete Reinspection Complete Passed No Reinspection Complete Reinspection Complete Page 1 of 1 SOLAR ELECTRIC SYSTEM NOTES: 1. ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: 2016 CA BUILDING CODE, PART 2 2016 CA RESIDENTIAL CODE PART, 2.5 2016 CA MECHANICAL CODE, PART 4 2016 CA ELECTRICAL CODE, PART 3 2016 CA PLUMBING CODE, PART 5 2016 CA EXISTING BUILDING CODE, PART 10 2016 CA GREEN BUILDING STANDARDS CODE, PART 11 2016 CA REFERENCE STANDARDS CODE, PART 12 2016 CA FIRE CODE 2. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 3. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(0)] 4. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 5. PAINT PV CONDUIT TO MATCH THE DWELLING EXTERIOR. 6. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM PROJECT SITE \ /~ 4 • '· ,4 .r" I ....... OllcoveiUf•CNll'ch' ,._.,,l· 9 PoM\&ntr,aOffli~NM)' ✓~ _.,,..,..~ ...... ~ l't,Mftt.'iQRoa,d \ ~ ~..,...,. i 'i \,. Pft.nroq,~ \ . ►.p1,""" " J '" ~tt•l.n \ .. p,otneet\•UI ,,,,,...,...,. ~ VICINITY MAP A NOT TO SCALE N ~ 0 >' ~ EJ G) Site Overview 1 SCALE: 1" = 30"-0" D - ray 4 18° 251° · PL ~ Array 3 T: 18° Az: 161° Module: (23) Panasonic, VBHN330SA 17E Inverter: (23) ENPAHSE IQ 7X NTEGRA TED WITH PV MODULE Main Service: (1) 200A MAIN PANEL, 200A MAIN BREAKER CO~D:rio~· ~t r-.??ROVAL x5 PV :p C~Q.r'f.!~ ,_ .......... ~ ;~•,' SYS~EM 0 EVC □WIND CB A~tq-Jf4~ Installation subif>ct to ficlr' •eview and approval. As-built code deficierciP,s shall be corrected as directeclJlY the Bui!d1,1g Inspector. 1Cf5{0'6 Lie# JtJ I q INDEX OF SHEETS: Sheet Description PV1 Title Sheet / Layout PV2 Roof Plan PV3 Structural Details PV4 Single Line PV5 Signage PV6 Specs PV7 Specs PV8 Specs PV9 Specs PV10 Soecs Array 5 T: 15° Az: 161° PL______,/' PL\ \ Array 2 T: 18° Az: 161° Array 1 T: 18° Az:71° 95'-9" ----PL- PL PL _I f/J --..... Q) ..... Q) :::, .c 0 (j) >, Q) j ~ i= z 5 a... ~ ~ > a.. (.)~ 0 ~ C/) Cl.<.) a, UJ >-~O > ~c::,C) >-\.J .....Jf:::! .... co ...,._ ON~~o O') 500zz~ LO 1-w S2 :s: o • 01-C/)<( UJ ..._ I<(Wa:'.I ,-0...0000 a, c:, c:, ~ a Sl UJ <( <( ii O <.) <( a:: --' <C Cl UJ <.) <( a: z -~ W>-~_, z <( <D a:: ~ :s: :::J: <( 0 0 N 0 0)- 0 ~ u.i <D >N <C N J ~ z O> ~o <C ct-o C/) a:: -..,wo :s ::i &'3 ju5 i5 a, O> 0 NOON °'o-""~ ~ '"'"" 0) 0) r=:: We::, o"'z "' a, <( '-' t-C/) ~a>o ~'II:·· ~<.)~ e::; w " . a: :5 ~ 0 ~ t ~ w 0 ~ ! i .... ;; C: 0 ., ~ {!. ROOF MOUNT NOTES (SEE PV3) I THIS SYSTEM IS CLASS A FIRE RA TED I Array 4 T: 18° Az: 251° CB □ □ 21'-8" 3'-9" '<- □ □ CJ --i----12'-2" ___ _,__ Array 3 T: 18° Az: 161° a □ 9'-1" CONDUIT RUN ON ROOF SIZED PER PV4 □ □ ENPHASE IQ 7X INVERTER Array 2 T: 18° Az: 161° G) s,, O~Mew -Callool1 O'\ SCALE: 1" 20' _ O" V Module Array Name TIit° Azimuth Count Array 1 1a· 71• 3 Array 2 1s· 161° 11 Array 3 1 a· 161 • 2 Array 4 18° 251° 2 Array 5 15• 161° 5 ARRAY AREA & ROOF AREA CAL C'S ROOF SOLAR Array 5 T: 15° Az: 161° T 3,038 SF I 86% I 415 SF I 14% Array 1 T: 18° Az: 71 • KEY LEGEND: MAIN SERVICE PANEL (E) GAS METER (N) INVERTER (N) AC DISCONNECT (N) DC DISCONNECT (N) AUTO TRANSFORMER (N) SUB PANEL (N) COMBINER BOX (N) JUNCTION BOX N) PV CONDUIT RUN ON ROOF OR UNDER EAVE (N) SOLAR MODULE ROOF SYMBOLS: (E) DORMER ATTIC VENT (E) CHIMNEY (E) ROOF PVC VENT (E) ROOF T-VENT (E) FLAT O'HAGINS VENT (E) HEAT EXCHANGE VENT (E) OVERHEAD UTILITY FEED (E) TURBINE ATTIC VENT (E) ROUND ATTIC VENT (E) ROUND SKY LIGHT (E) RECTANGLE SKY LIGHT (E)AC UNIT (E) SATELLITE DISH CAL-FIRE SETBACKS: 3' AT RIDGES & RAKE 18" AT HIPS & VALLEYS C N (I) IMSPI Cl. > = -0 a.. ~ 0 = 0:: = IINV! "' = IACDr 0 :=, = 1ocor .s <( "' ' ON = !ATSI ffl-~ = ISUBI = Q) in ·5 ~ z ~ 0 IT[] 0 "0 = u5 Cl o > w ci-0:: Zo = QID z '.5 0.. = -------------::; (.) ~ [Z] 0~ Cl. U) U) = Cl m W ~ ~08 ;;.; .!:I::: ~~;..::;;..:co ON com a O') E,COzz~ = 0 LO r-wS2S::u . o ,-u, ~w I"--~c§~o0 = ~ = a, = cmJ "' 0 0 0:: N [] => □-O') = w <( <( iio u <( 0:: • = (i}J _,<(Cl .. wut3 V ~z~UJ w >-_, z <( (0 0:: = 31: s: ::i: <( 0 Cl N (.) = @ "' I 0 0 .;; = ui "' X >"' ® « N = z "' nio<e a:i 01-u o:, 0 = D Cl)ffi O ~~~ .g> (.') '?~M [NJ 0.:;;;;!W ~~j::: = .9,!cn C mmo Woz i:o'::i:t:a..: U~ <C U"lS:;!X = cp (.'),_Cl) e....J w '"',:l F j = 0 en u ii: t; • ~ w • ...J ~ ~ w x u ~ :~; " 0 ~ ~ "~-·,"-f-:l-• ~}• ~ SYSTEM WEIGHT TOTAL SYSTEM WEIGHT: 1, 157.2LBS LBS/SF: 1,157.2LBS/415SF= 2.7 WEIGHT/ TOTAL LBS/STANDOFF: 1,157.2 LBS I 49 STANDOFFS= 23.6 DESCRIPTION QTY UNIT WEIGHT Module 23 42.99 988.77 Racking Parts 23 0.60 13.80 Rail 180 0.75 135.00 Standoff 49 0.40 19.60 REVERSE\ TILT r EVEREST CROSSRAIL 1"-" \ I ' I " \ j " I '\I ID □ 01 I I ,~I"-" ID l!J FIRE ACCESS AISLE ,~ ~ID ,, I I >--" □ ~r: ,,! □ ~ ~ ~ □ □,= ~ / " G) Array Plan In] = □ • I QUICKMOUNT QMHSS ' = = "' '---i::\/i::l:;,i::c:T u / - " I IV V ', ; " ~ C. 8 -v~ f/J / " MODULE CLAMP SOLAR MODULE EVEREST CROSS RAIL ROOF FRAMING TYP. (2) 5116" x 3-112", 18-8SS LAG SCREW, HEX HEAD @ Roof Standoff -QMHSS SCALE: 1" = 1'-0" SOLAR MODULE ROOF FRAMING TYP. @ Reverse Tilt Side View SCALE: 1" = 1'-0" ~ L-FOOT ATTACHMENT QUICKMOUNT QMHSS QUICKMOUNT FLASHING LIGHT WEIGHT CONCRETES-TILE 112" ROOF DECKING SEAL HOLES AND UNDER ROOF HOOKS MODULE CLAMP 0 (2) 5116" x 4", LAG BOLT ~ Cf) :::>= -co (.) -::, a., .!:-0 Cl) 0, 0 ::, 214' .,_ Cl N ~ § 0"' ., ., ~~5~ O "'o U) '3 0 > ' ~ ~lo z :5 a. ::;; CV) > a.. (.,,) i=' 0~ a.(/) (/) u 0, L1J > --'-' > ~o(9 ;...: ~ ---'o~;...:;:;..:m□ N a:, a:, O') e5<:0zz~ L.O ~0 w~S:u -~ (/) <( L1J ....__ I<CWO:::I 1--a.OClCIU g a::: ~ ~ ::, Cl L1J <( <( ~Ou <( a:: - ....I<(~ .. WOm ffi$=~~ z <C co 0::: :'1:3:::l=<C 0 0 NU !-I u.j co X >N <C;;; .... z ~ 0) ~~ (.) 0) 0 WO::: Q S!a::iN .g~ (.9 c-;,;=~ 1:,....1 w O')ll)-- Ji?ci? 0 ~~~ w a z cQ'f:t:: CL u~ <C ~~>< <.9 r--en -....1 w "'"' :s 5l 0 ~ irl 0 •.~· ,:t,;1f ./ ~ 1l. ~ :; WIRE CHART (ii) ITEM DESCRIPTION Q1Y MAX AMPS X BREAKER WIRE RATING X TEMP TERMMINATION @ NEC MULT •DESIGN AMPS SIZE {A) WIRE TYPE EGC DERATE X CONDUCTOR AMPS 0 CONDUIT SIZE OERATE • DERATEO WIRE 60-C & 75'C 0 PV MODULE PANASONICi HIT-V8HN330SA 17E Voe = 69.7V, Vmp = 58V 23 lsc = 6.07A, Imp = 5.70A W/ INTEGRATED ENPHASE 0 ENPHASE Q CABLE ® 15.7 X 1.25 = 19.6A 20 (2) #10 AWG, CU-THWN-2 #8 AWG, CU-THWN-2 EGC 40 X .82 X 1 = 33 >= 19 35 >=19 75'C 3/4" EMT, FILL:0.08, 37% IQ-7X MICROINVERTER 0/P POWER: 315W 0/P CURRENT: 1.31A @240VAC ® 15.7 X 1.25 = 19.6A 20 (4) #10 AWG, CU-THWN-2 #8 AWG, CU-THWN-2 EGC 40 X .82 X .8 = 26 >= 19 35 >=19 75"C 3/4" EMT, FILL:0.12, 57% © 30 X 1.25 = 38A 40 (3) #8 AWG, CU-THWN-2 #8 AWG, CU-THWN-2 EGC 55 X 1 X 1 = 55 >= 38 50 >=38 75"C 3/4" EMT, FILL:0.15, 69% 0 80 X 1.25 = 100A 100 (3) #3 AWG, CU-THWN-2 #8 AWG, CU-THWN-2 EGC 115 X 1 X 1 = 115 >= 100 100 >=100 75·c 1" EMT, FILL:0.33, 95% ~ PVC JUNCTION 4"x4"x2" UL LISTED WATER BOX TIGHT NEMA TYPE 3 3 ~ (E) MAIN (E) MAIN SERVICE PANEL & 1 SERVICE PANEL METER: 200A MAIN BUSBAR RATING W/ (E) 200A MAN BREAKER ~ (N) IQ N) ENPHASE IQ COMBINER 3 1 COMBINER BOX ·10-ca· 125A, 120/24ov. 11,,,. ...... ~,...-......... KEY NOTES: NUMBER OF CURRENT -SOLID BARE G.E.C. (FREE-AIR) MOUNTED UNDER ARRAY PERCENT OF CARRYING CONDUCTORS IN EMT -PER NEC 250.120(C): WHERE CONDUCTORS & GROUND WIRE ARE RUN EXPOSED ON FROM ARRAY TO J-BOX, CONDUCTORS & BARE GROUND WIRE SHALL BE CONCEALED INSTALL IN CONDUIT -PER NEC ARTICLE 690.35 INVERTER GROUND FAULT PROTECTION PROVIDED -ALL GROUNDS AND NEUTRALS BONDED TO EXISTING GROUNDING CONDUCTOR W/ IRREVERSIBLE GRIP CONNECTOR. -BACKFED BREAKERS MUST BE LOCATED @ OPPOSITE END OF BUS BAR FROM MAIN BREAKER OR MAIN LUG ON GRID SIDE. WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ 'LINE OR LOAD'. -PER CEC 250.64(C): CONDUCTOR SPLICES ONLY ALLOWED WITH COMPRESSION CONNECTORS OR EXOTHERMIC WELDING -ALL GROUNDS AND NEUTRALS BONDED TO EXISTING GROUNDING CONDUCTOR W/ IRREVERSIBLE GRIP CONNECTOR. -VERIFY (E) UFER GROUND NEAR MSP. IF (E) UFER IS NOT ACCESSIBLE OR VERIFIABLE, INSTALL A NEW 5/8"0 X 8' LONG GROUNDING ROD AND BOND SOLAR SYSTEM EQUIPMENT GROUNDING ACCORDINGLY. Branch 2: (11) MODULES ·2) {2b ••••• Branch 1: (12) MODULES 2o ••••• TRUNK CABLE (TYPICAL) 2o VALIIES .80 .70 Equipment !AC Voltaqe 00 Q 1~ --=--~~ oj_-J 4 ·6 7 9 10 20 BRANCH 0.44% BRANCH 2 0.44% 120% BUS RATING CALCULATION PER 705.12lD)(7) MAIN BUS = 200A MAIN BREAKER = 200A MAIN BUS X 120% =240A -MAIN BREAKER = 40A AVAILABLE FOR SOLAR SOLAR BREAKER -40A OK MAIN BUSBAR 200A r, c3 0 N TO (N) 100A suB--+--+~ . . • • • 120/240V 1PH, 3W 200A BUS PV BREAKER MUST BE INSTALLED AT END OF THE BUS~ _ _i __ = 1. USE ENPHASE Q CABLE Q-12-10-240 240VAC AC TRUNK CABLE FROM INVERTER TO JUNCTION BOX. FOR MORE DETAILS REFER TO ENPHASE MANUAL 2. NO NEUTRAL PRESENT AT INVERTER. ~ 0 Ql C :.J Ql °' .!:: en en 0 21~ "'~ ON C ~ a.. I l_glal I I I I z :'5 Q_ ~ (._)~ 0 ~ c.. (fJ </) u en w > -u > ~Cc, ;;,..; ~ __J~)-'.)-'.'° ONCOCC □ en 6«>zz~ LO bu..iQ3:u ~-:r:~f:3~~ •--a..ooou gi 0 a::: -~ ::>a w <( <( ~Ou <( 0:: . __J <( ~ .. w u co ffi~:E~ z <( (C) a:: ;;: s: :;i: <( OONU en· 0 ,;: w"' >"' « ;;; J -Zen ~~c) ~ ffi 0- en 0, ~ No:::,~ ·c: > (9 t5;;;;;;! w 2 U) 0 Woz u"' <( (9~ Cl) eno-~~E? 0, 0, ,_ O,O>Q 00:t:1: a.: ~ ~ CiS "cl :3 5l u ii: ~ ..J llJ u <., . ~r lg_ :ii. ~ ;; § ! ~ "WARNING" INVERTER OUTPUT CONNECTION DO NO RELOCATE THIS OVERCURRENT DEVICE (UNLESS BUSBAR IS FULLY RATED) 690.64(8)(7)-705.12(0)(7) "WARNING" ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PV SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED 690.35(F) HOTOVOLTAIC SYSTEM EQUIPED ~ WITH RAPID SHUTDOWN f----~ 690.56(C) ARRAY .-- CEC 605.11.1.4, CEC 690.31 (E)(3) & (4), CRC R331.2.4 WARNING PHOTOVOLTAIC WARNING PHOTOVOLTAIC POWER SOURCE EVERY 1 O' ON CONDUIT & ENCLOSURES (D Site Overview SCALE: NTS "WARNING" @ H DUAL POWER SOURCES r--7 SECOND SOURCE IS PHOTO-VOLTAIC SYSTEM L___J RATED AC OUTPUT CURRENT -30 AMPS ,AC NORMAL OPERATING VOLTAGE -240 VOLTS a:: w ti: ~ 690.54 "WARNING" ELECTRIC SHOCK HAZARD IF A GROUND-FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 690.64690.5(c) NOTES 1. CEC ARTICLES 690 AND 705 AND CRC SECTION R331 MARKINGS SHOWN HEREON 2. ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: A .. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B.RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK C.ARIAL FONT 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING POP-RIVETS OR SCREWS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN : 7 a 0 Ldol □I □I □I ol □I I ~ q q l q q: O "'~I~ .. \ PVMODULES _j N I G C Electric Solar SDGE SERVICE POINT AND UTILITY METERING 2446 MICA ROAD, CARLSBAD, CA 92009 PV Solar Back-Fed Circuit Breaker in Main Electrical Panel is AC Disconnect Per NEC 690.17 I! ~ Operting Voltage = 120/240V Max. Current = 30A 6"X8" TYP -705.10 Cl) Ol C\l C: Ol (/) a, ~ c!, .l!ll~ "' .!-D N C C: .Q: 0 V, "" ., en ·;::: o Z O >f?. 0 i8 ~ U) Cl~ > . W O ~ C,: Z 0 ~ a. ::;; I.{) > a.. u~ O(;: 0.. Cl) Cl) Umw > -~'-' :::> ~oe:> :;;..: ~ -'o ~ j..: j..: COD N ID ID O') 6a:Szz~ L.C') >-0 w s2 S: U • >-Cl"J«W ....._ :::C:<(WO:::J: •--a..ooou gJ 0 0:: -~ =>□ w .... u: 0 (.) .. "' --'<(~ ••WO Cl ffi~~~ Z<C.:oo:: 3:~~<( OON(.) a,- 0 ,. u.i "' >N « ;;; J ~ z a, ~o<C Of-U Cl) a:: -..,wo ·;::: > (.!) U:;;;;! w S? en 0 Woz (..) ~ <( "' ,__ Cl) a, a, ~ N CO ~ "'o-~LOf? "'a,,__ a,"' 0 co=i:t: a.: ~~~ 'a: :s Sl u ~ ci u .~·· 11. ll. ~ x § 1 !=- HIT. Photovoltaic Module AC SERIES Panasonic HIT® AC Series Advantage More power from every roof An Enphase IQ 7X microinverter with Individual MPPT !Module-level Power Point Tracker! is integrated with HIT® high efficiency solar technology to deliver maximum power production from every roof size and shape. The result is the HIT® AC Series, offering extreme efficiency and high power output for residential solar systems. Easy to Install No inverter installation and no DC wire management required. The built-in microinverter is factory mounted on the module, saving installation time, labor and money. Simple Logistics The Enphase IQ 7X recesses into the frame of the module, saving storage space, reducing trips up the ladder, and simplifying the purchasing process. Lower operations and maintenance (O&M) costs Each microinverter is field-replaceable without the need to replace the entire solar module. The operation and maintenance costs savings help maximize the ROI on your home solar system. High Efficiency at High Temperatures Where most modules weaken and underperform in hot summer temperatures, HIT® AC Series outperforms like no other module. Our industry-low temperature coefficient of -0.258%/0 generates more solar power than competing models on the warmest days. 9 ENP HASE. 25-year TripleGuard warranty provides complete system protection Backed by one of America's longest-standing brands, our comprehensive module warranty covers performance, workmanship and parts for 25 years. Our guaranteed minimum 90.76% rated power output after 25 years means you'll produce more electricity and save more money year after year. PERFORMANCE WARRANTY DEPENDENCE ON IRRADIANCE 700 IOOOW/m 6.00 i---....----..---+---,----- --I -n,-, ■P,naonic ■c-.ntioMI 500 .,,,,,n1 s ! 400 (.) 300 200 !200W·rrl 100 000 0 10 20 R•fereoce data for modt-1: V8HN330SA.17 fCeU temperatuni: 2s•c1 30 .. .. Voltage IV} 60 10 80 HIT• is• ,-g,,tet"ed lr&demMk of Panasonic Group (D Spec Sheet Module Panasonic 330 NTS HIT. Photovoltaic Module AC SERIES DC ELECTRICAL SPECIFICATIONS Raled Powtr 1Pniaxl1 Maximum PowerVoltage IVpml Maximum Power Current ltpml Open Circuit Voltage !Voci Short Circuit Current II.sci Temperature Co4ffic1ent {Pmaxl Temperature Coefficient !Voci Temperature Coefficient Use) NOCT CEC PTC Rating ITentath1el Cell Efficiency Module Eflidenq Watts per Ft.t Maximum System Voltage Series Fuse Rating Warranted Tole,...nce 1·/•J MECHANICAL SPECIFICATIONS Internal Bypass Diodes Module Area Wetght Dimensions Ll.W)CH Cable Lenglh +Mate/-Female Cable Size/ Type Connector Type1 Statit Wind/ Snow Load Pallet Dimensions LxW1<H Quantity per Pallet/ Pallet Weight Cuanltty per ,o· Container Quantity per 20· Container 330W 58.0V 5.70A 69.7V 6.07A -o.2S8%rc -0.l6V/°C 3.34mA/9C 44.0°C 22.09'4 19.7'1, 18.JW 600V 15A •11l'll/-0'11' , Bypass Diodes 18,02 Ft2 ll.67m~I 42.99 Lbs.119.Skgl 62.6x4 l.5x1.6 in. l1590x1053x.40 mml 40.2/40.2 ,n.11020/1020 mm! No. 12 AWG / PV Cable Multi-Contact• Type IV fMC4'"l 112 PSF IS400Pal 65.3 x 43.7,: 48.S in. 24 pcs./1098 Lbs.1498 kgl 672 pcs. 288 pcs. OPERATING CONDITIONS & SAFETY RATINGS Open•ting Temperature Hail Safety Impact Velowy Safety & Rating Certifications UL 1703 Fire Classification L1m1ted Warranty Manufacturing Locations -22°F to 185°F 1·300C to 85°CJ 1" hailstone (25mml at 52 mph (23m/sl UL 1703, cUl. CEC Type2 Module: 25" • Yrs Workmanship and Power Output IL1nearJ• •~ Micromwrt~ 25 Yrs Worit.mansh1p and Mar&nals' USA NOTE: Standard Test Cond1IK>M, Air m.ss 1.5; rrradiaoc. • 100/JW/m'-; cfiltemp. 25"C • M1;,ornum ~, at deliYery For gu~ninlff condrt1ons, plefft d\e<:k our guani/'ltee document ··~~~~1~r=~~~~~~='t.1t1:i:1ls~~ ••• 1s.1 yur9~.11IIH 2ndyHrO26%aMualct.gradaoon lo year 25. ' Norn1n1I voltage ran9" c." be e•tende<I beycnd nomm.at 11 requlfff by the utility "Umrts may-,.y. ~l!t to local. requirements to def~ the nurnbff<M nucroirwtrten J)t1" bi"¥1Ch in 'JOlX' aru 1 M~romverter warr1n1y pn>YHled by Enph1se Plu,e rell!r lo Pana5onlc·• HIT AI:. Module l itn1led W1rran1y Documant for further mlormauo11 Panasonic ( AC ELECTRICAL SPECIFICATIONS Peak Power Output Maximum Continuous Output Power Nominal (L-Ll voltage/range• Mruumum Continou!i Output Current Nominal Frequency 320VA 315VA 240V / 211 -264V 1.31A@240VAC/ 1.51A@208VAC 60Hz Extended Frequenq Range 47 -68Hz AC Short Circuit Fault Current Over3 Cyclts M.wmum Units per 20 A IL·U Branch Circuit" OveNOltage Class AC Port 5.8Arms 12@ 24DVAC / 10@ 208VAC 111 AC Port Backfeed Current Pow&r Factor Setting Power Factor !adjustable} CEC Weigh!~ Eftkiency FEATURES Communication Communication Disconnecting means Complianc!' DIMENSIONS OA 1.0 0.7 leading/ 0.7 taggmg 97.5'1,@ 240V / 96.5'11@ 208V Power Line Communication IPLCI Enlighten Manager and MyEnlighten monitonng optk>ns. Compatible with Enphase IQ Envoy The AC and DC connectors have been evaluated and apprl!Yed by UL for use as the load-break disconnect required by NEC 690 CA.Rute21 UL62l09-l, UL1741/IEEE1541, FCC Part ISctass B. ICES-0003 Class 8, CAN/CSA·C222 NO. 107.1-01 This procklcl is UL Usttd as PV Rapid Shut Down Equipment and conforms with NEC-201' ~ NEC-2017 section 690.12 and C22. 1 ·2015 Rute64~218 RapidShutcbNn of P'r/~ems., lor /C..and DC condvctot's. when installed according to mtnufttturer's rnstruct,ons ,. lT ' l ~------- 'STC: C.tl lffllll. 25"C, AM1.5, 10MtN/m' 1 Safety lock1"9 clip IPV-SSH41 ts not suppllffwith tka module NOTE: SpN.rtic.alrons and ,nfonnal,on •bove rn-v cl'lengt without no11ce CJ) (.) Q) Cl.. (f) en ~ ch ::, 21-f ro ~ Cl N C 5 ·~ .. ""~ (./') ·c:: z o?f!_ 0 "'o u5 ~ ~ (0 > a.. > l--.+-+---t--t--r-7 W O ~ a:: z C> \ z :5 0... ~ (_) ~ 0 ~ C/) Cl.uenw <(~,., .. S -u 1-c::,....., >-~ o_, ~ ;;..: ;;..: oco NCO CO 0) >oozz~ LO ~w~~u • 01-C/l~W ,..._ ~c3~ol5 en C> a:: C> N ::, c5 en W<(<( iio u <( a:: -_J <( 0 •· WU~ ffi ~ :E C/) Z <(co_, ~ ~ ~ ~ 0 ClNU cr> I C> ~ u..i co X >N <C ;:; z en t;;o <C en 01-u en ~ C/) a:: -~~§ 0 w0 <"? T""" --·.:: > C) eno.o<"> u=~ a,cnr=::: -9,! C/) 0 en en C> wo 2 -:it:·· u I.() <( ~00... C)~C/) ~::::;i';'.J ~,l ::5 0 VI u ii: t; w ..J w u 1/ ~ II) Q. ,-.. >< :: C: 0 Q) 1§ "' 0 ,1-., Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) ® LISTED To learn more about Enphase offerings, visit enphase.com (D Spec Sheet Enphase IQ Combiner 3 1 NTS The Enphase IQ Combiner 3'" with En phase IQ Envoy'" consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Simple Reduced size from previous combiner Centered mounting brackets support single stud mounting Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year warranty • UL listed 9 ENPHASE. Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X·IQ·AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy* printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/· 0.5%) and optional• consumption monitoring(+/· 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect~ CELLMODEM-03 (4G / 12-year data plan) CELLMODEM-01 (3G / 5-year data plan) CELLMODEM-M1 (4G based LTE·M / 5-year data plan) Consumption Monitoring* CT CT-200-SPLIT Circuit Breakers 8RK-10A-2-240 8RK-15A-2-240 BRK-20A-2P-240 EPLC-01 XA-PLUG-120-3 XA-ENV-PCBA-3 ELECTRICAL SPECIFICATIONS Rating System voltage Eaton BR series busbar rating Max. continuous current rating (output to grid) Max. fuse/circuit rating (output) Branch circuits (solar and/or storage) Max. continuous current rating (input from PV) Max. total branch circuit breaker rating (input) Production Metering CT MECHANICAL DATA Dimensions (WxHxD) Weight Ambient temperature range Cooling Enclosure environmental rating Wire sizes Altitude INTERNET CONNECTION OPTIONS Integrated Wi-Fi Ethernet Cellular COMPLIANCE Compliance, Combiner Compliance, IQ Envoy Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Split core current transformers enable whole home consumption metering(+/· 2.5%). Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker. 2 pole. 20A, Eaton BR220 Power line carrier (communication bridge pair), quantity 2 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) Replacement IQ Envoy printed circuit board {PCB) for Combiner 3 Continuous duty 120/240 VAC, 60 Hz 125A 65A 90A Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) 64A 80A of distributed generation/ 90A with IQ Envoy breaker Included 200 A solid core pre-installed and wired to IQ Envoy 49.5 x 37.5 x 16.8 cm (19.5" x 14.75" x 6.63"). Height is 21.06' (53.5 cm with mounting brackets). 7.5 kg (16.5 lbs) -40° C to +46° C (-40° to 115° F) Natural convection, plus heat shield Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. To 2000 meters (6,560 feet) 802.11 b/g/n Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM·M1 (4G based LTE·M) (not included) UL 1741 CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) UL 60601·1/CANCSA 22.2 No. 61010·1 * Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All nghts reserved All trademarks or brands in this document are 1eg,stered by their res~t,ve owner 2018-09-13 9 ENPHASE. (J) u Q) 0. (f) 0) -6 :::> ~11 ON C: C: .Q: ~ ~ en ·c: o z u cft!. 0 V) 0 u5 i3 ;= I'--> a.. " > l-.+-+--+--r--t-7 w o-0::: zo z ::5 a.. ~ (.) ~ 0 ~ (/) Q_Uo,W <( -rn · • S -u 1-0 '-' >-~ 6~~~~ 0) 5cozz~ I.{) 1-wQ~u • 01-U)<(W ...._ ::C<(WO:::::C •-a..ooou 0) 0 0 o::: -Sl =>o w <( <( ii ou <( 0::: - ....J <( ~ .. WU CD ffi ~:E~ z <(<00::: ~ ~ ~ <( OO NU 0)- 0 ~ u.i <O >N <C N z 0) J 0) ffiO <C 01-u 0) -~~§ (/) 0::: -uW 0 '? ._ sr-·;::: > (!) a, <n M o ::::! w O') 0, ;::: ..!!!U) ci O,O>c, Wc,2 -:it.·· u.,, <( ~ua.. (!)~(/) e2.:::J i:;) ~,x ::5 0 V) u c:: I-u w ..J w u <., Vi ~ "' a. "' a. .... x :: C 0 2 :3 "' 0 \.. ,I-./ ~ ~ iv i.,.., w .i:,. .I>, Vl 11) "O ,:., s !") :0 11) < ..... 0 -ir.29 1 BOTH SIDES OF SLOT SERRATED DIMENSION QMHSS QMHLS A 6.57 6.30 2.50 B 2.21 l.93 C l.89 l.60 A ~ I r~~ 4.53 ,IT (/J .40 ~ r----7 _l D 6.27 6.00 (") ~6.oo--J C">I I I t__ .1 9 -----9 .03 -------- #3 TYPE l (PHILLIPS) DRIVE ON SCREW IT] l_ C II I I I 11 11 17 11 1.50 T SLIDE TO DESIRED LOCATION ITEM NO. 2 1 0 0 0 0 0 0 IDENTIFYI NG MARK ON QMHLS ONLY DESCRIPTION BASE PLATE, QUICK HOOK, 6", 6061-T6, MILL LAG SCREW, HEX HEAD, 5/16" x 3-1/2", 18-BSS E DETAIL E SCALE 1: 2 3 I QUICK HOOK, STANDARD/LOW HEIGHT, VERTICAL, 1.5", 6061-T6/6005A-T61 , MILL 4 I SCREW. SELF-TAPPING, #12 X 5/8", 18-BSS, MILL 5 I SUBFLASHING, QUICK HOOK, 6" BASE, 9" X 14" X .032", 3003-0, MILL QTY. 2 OJ DO NOT USE IMPACT DRILL ON SCREW Q_uick Mount PY" --TITLE: QMHSS & QMHLS : QUICK HOOK FOR SIDE MOUNTED RAILS UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES ~ SIZE I DRAWN BY: RAD REV TOLERANCES: t ~--J...f _____________________________________ r-_...JfL----'1---J, FRACTIONAL! 1/8 : DONOTSCALEDRAWING lWOPLACEDECIMAL '·!~-L T ,- I THREE PLACE DECIMAL ~CA~ WEIGHT: 1 .82 I SHEET I OF 2 PIOPllfTAIY AND CONRDENTlAL THE INfORMATION CONTAINED IN THIS DRAWtNG IS THE SOLE PROPERTY Of QUK:K MOUNT PV, ANY REPRODUCTION IN PART OR 1'S A WHOLE WITHOUT THE WRITTfN PEllMISSION OF QUICK MOUNT PV IS PROHIBITED. A DATE: 1/8/2016 10 s 4 3 2 (D Spec Sheet Quick Mount QM HSS-1 NTS I (/) () Q) c.. (j) O> ~ 0 21~ "'~ ON C C .Q'. o en = a, co > a.. en ·co Z O ?fl. 0 "'o u5 ~ ~ > . UJ O ~ 0:: Z o z ::5 a.. ~ (.) ~ Cl ~ c.. Cf) Cf) UmUJ <( ~ ,n , . S -u 1-0'-' >-~ 6~~1£~ 0) 6cio zz~ L.() 1-wS2s=u .01-cn~w r----iti:§~00 O> c::, c::, 0:: N ::::> 0-O> UJ <( <( ~Ou <( a:: - _J <( ~ ••lJ.JUa:i ffi~~~ z <( "' a:: 3:S:'<f'<C 0 oc=:!i u a; c::, ~ w"' >N J <e N ~ z O> .!!l O <( 0 I-U Cf) a:: -c..,UJO ·c > (!) 13;;;:!W .92 en B We::, u U') z ,n O> <( '-' ,._ Cf) O> O> 0 Na:,N O>c::,-'7 --~ O> U') -O> O> ,._ O> O> c::, ~'it a.: ~Ux eJw ~cl :5 0 V) u ii: I-u w ..J w u ¥' ~,, ., ~ ., a. ,._ >< C 0 ! ., {=. Quick Hook® SS & LS Instructions for Installing Standard and Low Height Hooks for Side Mount Rails Installation Tools Required: stud finder, tape measure, utility knife, drill with 7 /32" bit, impact drill with 1/2" socket, #3 phillips power bit (use with drill only), caulking gun, appropriate sealant compatible with roofing materials, roofing bar, hand broom, electric grinder with a 4.5" triple sandwich tuck point blade. Remove the tile at selected location of the mount. Locate and mark the center of the rafter. a 4 Slide hook into desired position within valley of the tile . Hook must not overhang the sides of the base plate. Drive self-tapping screw using a #3 Phillips bit on a screwdriver or drill with clutch set at a medium torque, to secure hook to base. Do not use Impact gun on screw, Rest the base plate over center of rafter and mark center of holes, Drill two 7/32' pilot holes and fill with sealant compatible with roofing materials, Carefully clean the underlayment then apply bead of sealant compatible with roofing materials in the shape of an upside down U on the backside of the sub-0ashing, and install flashing CNer mount. Fasten sub-flashing to deck with one roofing nail in each top comer. Do not nail bottom comers. Cut a clearance notch in the weather guard lug using Bolt the side-mounted rail of your choice to the hook, a grinder with a tuck point blade. Make sure the tile using the rail manufacturer's hardware. seats back down in it's original position. Leave at least 1/, • of tile to prevent breaking through. Bl 7.2.3-34 (D Spec Sheet Quick Mount QMHSS-2 NTS Connect hook to base plate and drive lag screws into rafter through the two holes to a solid, snug fit. DO NOT over tighten lag screws, this may compromise their holding strength. :·~ · .. --'~ ··;:2 • ·" } .•. ·tr. . ! ;r,·F-r';: < • :(_·, ~-- ittf,, r : . _. . · .f i.. 1/! Quick Mount PV recommends installation per the Tile Roofing Institute guidelines with a base flashing. Alternative flashing methods may be approved by the AHJ at their discretion. Sep-2018, Rev 1 O (/) (.) Q) 0.. (/) 0, ..-0 :::, 21~ (ti ..- 0 N C § ·~ = Q) O') > a.. ' . . Cl (/) ·c:: z (..) cf!. Q Ille:, u5 c3 ;:: > . W O ..-0::: Z 0 "" z ::5 a.. ~ (.)~ 0 ~ Cl) Cl) 0..Uo,W > -u > ~oC) :;.: ..:::it::.. ....J~:,.::,.:co 0 N COCO Cl O') ejro z z~ LO t-wS:2~u • 01-Cl)~ w t-5: c3 ~ Cl t5 0, 0 0 a:: -~ :::, Cl w <( <( ii O u <( a:: - _J <( ~ •• WU CD ffi ~ ~ ~ z <( co a:: 3:~::;J:<C O ONU a; 0 ~ u..i co >N <C N J ~ z 0, .!!10 <( 0 I-(.) Cl) a:: -..,wo E~@ ju55 0, 0, 0 No:,N °'o -=..-..-d, U"l C2 0, 0, r--- 0, 0, 0 ~=tt •. We:, U'°Z C)~~ ~(.)~ ~::J w "~ ~ 0 en u ii: t w ..J w u (!I _¥ ~ ~ ,-. X C: 0 "' ~ {!. CrossRa il Technical Sheet Mounting systems for solar technology 48-S 48 80 t PA.f.M.2 ~ ~ $-® **All dimensions are in mm unless otherwise specified ITEM NO. DESCRIPTION EverFlash Comp Kit, 1OX12" 2 Lag Screw 5/16 "X3 • 18-8 SS 3 L-Foot UL 2703 Set, CR48-S/48/80 4 CrossRail 48-5, Mill, Dark Anodized 5 CrossRail 48-5 End Cap 6 CrossRail 48, Mill, Dark Anodized 7 CrossRail 48 End Cap 8 CrossRail 80, Mill, Dark Anodized 9 CrossRail 80 End Cap 10 Mid Clamp UL 2703, 55, Silver Set 30-S0mm CR 11 End Clamp UL 2703, 55, Silver Set CR G) Spec Sheet Racking Everest Crossrail NTS ? ? CERTIFICATE OF COMPLIANCE Certificate Number 20171017-E467724 Report Reference E467724-20150108 Issue Date 2017-OCTOBER-17 Issued to: Everest Solar Systems Ste 111 3809 Ocean Ranch Blvd Oceanside CA 92056 This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS USL -Everest Crossrail System, utilizing Crossrail 48, 48-S, 48-X rails, and Everest MiniRail XPRess System for System Fire Classification and Bonding. USL-Everest CrossRail System, utilizing CrossRail 80 for Bonding. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 2703, Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for use with Flat-Plate Photovoltaic Modules and Panels Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. ~~ Brue. M~ Olr«:tof" North AINrtca1 C«tlf!Qltion Program ULU.C Any infomwtion Incl docwntntatfon imol'+'infl UL Martt HNfoes .. pro'lfffd on behd of lit. LLC (Utl or any aithorind Hun ... of UL fot quadona, P'UM contact • kJcal UL C.stomw ~ Repr...ntlltfw at htlp;l,\II COU(lboutyl/k)qtlofl( Page 1 of 1 ® /' CF) (.) (1) Q. Cf) a, ~ 0 ::::, .sll<f <ll ~ ON 0 ~ > a.. ' C C .Q: 0 (J) .. :,:,~ CJ) ·c: Z u :=::e o ~b u5 0 ~ > . w o ~ 0::: Z o z ::i a.. ~ (_)~ 0 ~ -(/) (/) ~omw <(~,,, .. s: -(.) I-0 '-' >-~ a~~~~ O') 5coz z ~ LO 1-wS23::o • 0 1-(f)<(W ...._ I <CWO:::I ·-0..0 0 00 a, 0 0 0::: -~ ::::>o w <( <( iioo <( 0::: - -' <( ~ .. w (.) cD ffi~~~ Z <(<0 0::: 3: 3:: ~ <( Q ON(.) 0>- 0 ~ u.i <O >N <C c::i J ~ z O> !!! 0 <( ol-o (/) 0::: -c..,WO ·.::: > C!) u ~w __gi (/) 0 Wo o.,.,z "' a, <( '-' r--(/) a, O> 0 N 00 N O>o -'? --M a,u-,_ a, a, r--0> 0> o ~~ .. f?lo~ e ::J w "~ :3 0 II) u 0: 9 .J w u ~ - ~ "' a. ,.._ E g I~ {!.