Loading...
HomeMy WebLinkAbout2450 IMPALA DR; B; CB010094; Permit03/22/2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB010094 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2450 IMPALA DR CBAD St: B Tl Sub Type: INDUST 2090412000 Lot#: $344,091.00 Construction Type: Reference #: SENSA 7,473 SF WAREHOUSE TO OFFICE 0 VN Applicant: LARRY WHARTON Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Owner: MULLER-IMPALALLC ISSUED 01/09/2001 RMA 03/21/2001 03/21/2001 Total Fees: $19,477.89 Total Payments To Date: $1,636.17 t^e: $•Balance Drfe: $17,841.72 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Inspecto $1,301.16 MeterSize $0.00 Add'l Reel. Water Con. Fee $845.75 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $72.26 PFF $0.00 PFF (CFD Fund) $0.00 License Tax $0.00 License Tax (CFD Fund) $0.00 Traffic Impact Fee $0.00 Traffic Impact (CFD Fund) $0.00 LFMZ Transportation Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL Master Drainage Fee: $0.00 Sewer Fee: $0.00 Redev Parking Fee: TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $6,262.46 $0.00 $2,712.00 $0.00 $0.00 $125.00 $210.00 $73.00 $0.00 $7,876.26 $0.00 $19,477.89 Clearance: NOTICE: Please take NOTICEThat approval of your project includes the "If/positign" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired, PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY. PLAN CHECK NO. EST, VAL. ~7 JT •? ._. _ /. v -"/Plan Ck. Deposit Validated By__ __/_ Date / ' Name Address City State/Zip Telephone # iPERTY OWNER Name Address City State/Zip Telephone ft ,'WtHMam»' COMPANY HAWS (Sec. 7031 .5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of;Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more then five hundred-dollars [$500]}. PL Name State License # VYV » 0 j Address $ License Class / A- ' City State/Zip City Business License # & \ / Telephone # y« Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: G I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. O I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier arid policy number are: Insurance Company EQ&/E-T" f3i<*|VfV£. Lp TTf\£ Policy No./)/^ C3fo/j>£ <f Expiration Date C/Ol/o/ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS !$100J OR LESS} Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure tOMCure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dol\BTt^aO,OQM. in/Addition to trwaost of/eompensation, damages as provided for in Section 3706 of the Labor code. Interest and attorney's fees. SIGNATURE f srt0dio K *!/&^frr^MU-. DATE / ~~~7 I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). Q I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFRCE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS OCATtON I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commencecLwithin 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced $a; period of J80 j$s (Sectiojn 106.4.4 Uniform Building Code). SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lit<r'Wm Plan Check #: Permit #: Project Name: Address: Contact Person: Sewer Dlst Inspected, ^_ Bv: /> J Inspected Bv: inspected By: Comments: CB010094 SENSA 7,473 SF WAREHOUSE TO OFFICE 2450 IMPALA DR #B CHUCK Phone: 61 9341 1 025 CA Water Dist: CA ^? A Date / / CJWeJ^ j Inspected: ~7////0t Date Inspected: Date Inspected: Date: Permit Type: Sub Type: Lot: 0 Approved: ^ Approved: Approved: 05/22/2001 Tl INDUST ^^ Disapproved: Disapproved: Disapproved: Inspection List Permit*: CB010094 Type: Tl Date Inspection Item 07/30/2001 89 07/30/2001 89 07/27/2001 89 07/27/2001 89 07/16/2001 14 07/06/2001 14 06/29/2001 84 06/26/2001 17 06/21/2001 14 06/21/2001 16 06/19/2001 14 06/19/2001 34 05/22/2001 89 05/17/2001 14 05/16/2001 14 05/16/2001 27 05/15/2001 27 04/20/2001 14 04/20/2001 17 04/09/2001 14 04/09/2001 17 04/09/2001 24 04/09/2001 34 04/04/2001 16 04/03/2001 14 04/03/2001 24 04/03/2001 34 04/03/2001 44 04/02/2001 84 Final Combo Final Combo Final Combo Final Combo Frame/Steel/Bolti ng/Weldi n Frame/Steel/Bolting/Weldin Rough Combo Interior Lath/Drywall Frame/Steel/Bolting/Weldin Insulation Frame/Steel/Bolting/Weldin Rough Electric Final Combo Frame/Steel/Bolting/Weldin Frame/Steel/Bolting/Weldin Shower Pan/Roman Tubs Shower Pan/Roman Tubs Frame/Steel/Bolting/Weldin Interior Lath/Drywall Frame/Steel/Bolting/Weldin Interior Lath/Drywall Rough/Topout Rough Electric Insulation Frame/Steel/Bolting/Weldin Rough/Topout Rough Electric Rough/Ducts/Dampers Rough Combo 1NDUST Inspector Act PS - - PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS AP Rl Rl CA AP AP CO AP AP AP CO CO NS AP NR AP CO AP AP PA PA PA PA PA PA PA PA NR CO SENSA 7,473 SF WAREHOUSE TO OFFICE Comments POLY GAL WALLS T-BAR T-BAR OK TO INSULATE NEW DETAIL ON WALLS NO TEST T-BAR BATH RM PA REST UP STAIRS ROOM UP DOWN STAIRS ONLY NOT RMS WALLS 116&117 Wednesday, August 01, 2001 Page 1 of 1 City of Carlsbad Bldg Inspection Request For: 07/30/2001 PermiW CB010094 Title: SENSA Description: 7,473 SF WAREHOUSE TO OFFICE Type:TI Sub Type: INDUST Job Address: 2450 IMP ALA DR Suite: B Lot 0 Location: APPLICANT LARRY WHARTON Owner: WILLAT FAMILY TRUST 07-03-92 Remarks: Total Time: Inspector Assignment: PS Phone: 6193411054 Inspector: Requested By: CHUCK Entered By: ROBIN CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act> Comments Associated PCRs Inspection History Date 07/27/2001 07/16/2001 07/06/2001 06/29/2001 06/26/2001 06/21/2001 06/21/2001 06/19/2001 06/19/2001 05/22/2001 05/17/2001 05/16/2001 05/16/2001 05/15/2001 04/20/2001 04/20/2001 Description 89 Final Combo 14 Frame/Steel/Bolting/Welding 14 Frame/Steel/Bolting/Welding 84 Rough Combo 17 Interior Lath/Drywall 14 Frame/Steel/Bolting/Welding 16 Insulation 14 Frame/Steel/Bolting/Welding 34 Rough Electric 89 Final Combo 14 Frame/Steel/Bolting/Welding 14 Frame/Steel/Bolting/Welding 27 Shower Pan/Roman Tubs 27 Shower Pan/Roman Tubs 14 Frame/Steel/Bolting/Welding 1 7 Interior Lath/Drywall Act CA AP AP CO AP AP AP CO CO NS AP NR AP CO AP AP Insp PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS Comments POLY GAL WALLS T-BAR OK TO INSULATE NEW DETAIL ON WALLS NO TEST T-BAR BATH RM UP STAIRS City of Carlsbad Bldg Inspection Request For: 05/17/2001 Permit# CB010094 Title: SENSA Description: 7,473 SF WAREHOUSE TO OFFICE Inspector Assignment: PS Sub Type: INDUST 2450 IMPALA DR B Lot Type: Tl Job Address: Suite: Location: APPLICANT LARRY WHARTON Owner: WILLAT FAMILY TRUST 07-03-92 Remarks: WALL INSPECTION ???? Phone: 6193411025 Inspector: Total Time: CD Description Act Comments [4 Frame/Steel/Bolting/Welding /Tr Requested By: CHUCK Entered By: CHRISTINE M&tS 'Denfit- fa. Associated PCRs Inspection History Date Description Act 05/15/2001 27 Shower Pan/Roman Tubs CO 04/20/2001 14 Frame/Steel/Bolting/Welding AP 04/20/2001 17 Interior Lath/Drywall AP 04/09/2001 14 Frame/Steel/Bolting/Welding PA 04/09/2001 17 Interior Lath/Drywalt PA 04/09/2001 24 Rough/Topout PA 04/09/2001 34 Rough Electric PA 04/04/2001 16 Insulation PA 04/03/2001 14 Frame/Steel/Bolting/Welding PA 04/03/2001 24 Rough/Topout PA 04/03/2001 34 Rough Electric PA 04/03/2001 44 Rough/Ducts/Dampers NR 04/02/2001 84 Rough Combo CO Insp Comments PS NO TEST PS T-BAR PS BATH RM UP STAIRS PS PA REST ROOM UP PS DOWN STAIRS ONLY PS PS PS PS PS PS PS PS NOT RMS 116 & 117 WALLS SENSA BY W I L L A T World's Most Comfortable Pen May 17, 2001 City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 RE: 2450 Impala Drive Building Permit #CB010094 I am writing at the request of your field inspector, Paul Smith. Paul asked for a letter informing you of our intent to relocate our staff to the recently completed ground floor portion of the ongoing office remodel. The ground floor office space is now complete for occupancy except for the cabinets and two sinks. All life safety issues are compliant per your field inspectors' site visit of 5/16/01. It is necessary for our staff to vacate the second floor to allow Bycor access for remodel work. We appreciate your efforts. Thank you for your cooperation. Sincerely, Ted Caligiuri Chief Operating Officer (760)603-2120 2450 IMPALA DRIVE • CARLSBAD, CALIFORNIA 92008 TEL: 760 603-2100 • FAX: 760 603-2180 OHrn -4 *R 5r o ^> PP ! M • !O I ^ I TJO m 73 r~m rzm 73 M>!«^2nxlsS?* $'»fu*r$ r * •». A ?v* C$ x ?.3.ft Ac *^ if Mo*43O uoaopIP ^O» I• ~L< i H-fP iiHH fefe U-lcc K ^^•-M h- k i- r-'i P <b \~t5 O Vi r __ ' ! ^-— fc !' Ol- n o o : O f o^ 2Kr I* U H- k fe1 S>' H-^H- tui i- Co JJ r-r 8 ?•u? siX"^ M U) • t^ ft* g & U. -^u l^» i-J JU, -:-i-r^i-i- -=!\-L^-n-'^- ;«»i F- i~=- )>• •« •%* —;- r w ,w.*J « a•O 1^1is _; K--V is!. H i IH- u IT OO rl ! r Vioo f !' •>_4 •a < 5Jt^r 8 I--<t -O; \ •o HfM* K-h• 1 v'' I V r***R V h NJ n H-flH-WH- .— ^r _• *,-* I ;u - w ,u "Z--**t fc I' H-Bs \~ l I CI C.' u p Jis ^^ Nj M EsGil Corporation In <PaTtneTsbip witfi. government for 'Suiting Safety DATE: March 16, 20O1 Q AEEUCANT JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: O1-O094 SET: IV PROJECT ADDRESS: 2450 Impala Drive PROJECT NAME: Office T.I. for Sensa The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person n ^ REMARKS: Please have the designer slip sheet the other set of plans to the other set of plans to include the city's set. f^fo i4*^&~*- duk"TJ2II \ i/ By: Bert Domingo Enclosures: Esgil Corporation D GA D MB D EJ D PC Log trnsma.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with government for Wuitding Safety DATE: March 15, 2001 Q APPLICANT JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: O1-OO94 SET: III PROJECT ADDRESS: 2450 Impala Drive PROJECT NAME: Office T.I. for Sensa The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted fora complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Stephen G. Brown 6315 Muirlands Dr., San Diego, CA 92037 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Larry Rowe Telephone #: (858) 459-8050 Date contacted: 31 '5lo, (by: ft*) Fax #: (858) 587-1903 Mail ^-Telephone (f&j& In Person REMARKS: By: Bert Domingo Enclosures: Esgil Corporation • GA MB D EJ D PC 3/6/01 trnsmtt.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 Carlsbad O1-0094 III March 15, 2O01 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 01-0094 PROJECT ADDRESS: 2450 Impala Drive SET: III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 3/6/01 March 15, 2001 REVIEWED BY: Bert Domingo FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad 01-0094 III March 15, 20O1 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • PLUMBING, MECHANICAL AND ENERGY CORRECTIONS 4 JURISDICTION: Carlsbad DATE: 3/14/01 4 PLAN REVIEW NUMBER: 01-0094 SET: HI 4 PLAN REVIEWER: Glen Adamek 2. Correct the note #29 on sheet TS1 of the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the exempt quantities listed in UBC Tables 3-D and 3-E. Not "That exceeds current UBC?" No response found? PLUMBING (1997 UNIFORM PLUMBING CODE) 3. Please provide required backwater valve for the new floor sink in the Office #111, at water heater. As per UPC, Section 710.0, provide backwater valves on all building drains which serve plumbing fixtures with flood rim elevations below the upstream manhole rim elevations. Only fixtures with flood rim levels below the upstream manhole rim elevation may flow through a backwater valve. Carlsbad O1-0094 III March 15, 20O1 • MECHANICAL (1997 UNIFORM MECHANICAL CODE) 5. It is assumed from the response of "NA" that no Class I, II, or III-A liquids are used in any amount in the building. If so clearly not on the plans: "No Class I, II, or III-A liquids are used in any amount in the building." No response found? 6. It is assumed from the response of "NA" that no combustible dust is produced or used in the building. If so clearly not on the plans: "No combustible dust is produced or used in the building." No response found? • ENERGY CONSERVATION 12. The MECH-3 form for the new HVAC units do not include the required Occupancy Dated ventilation calculations. Not corrected, the Columns 'E', 'F', and 'G' are blank on the MECH-3 forms. Please complete. 14. On the plans clearly show the wall insulation locations, thickness, and R-values, as per the energy design. Not found on the plans? 20. The PERF-1 and LTG-1 forms on the plans must be completed and signed: A) ' The Principal Lighting Designer must sign the LTG-1 form on sheet E-1. B) The Documentation Author, the Principal Envelope Designer and the Principal Mechanical Designer must sign the PERF-1 form on sheet M.4. Note: If you have any questions regarding this plumbing, mechanical and energy plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad O1-O094 III March 15, 2O01 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation. Thank you. FROM : DELLCO FftX NO. : 760-9400064 Mar. 15 2001 01:56PM PI MECHANICAL VENTILATION MECH-3 PROJECT NAME Sensaby WillatT.L DATE 3/15/01 ICJ Ifil 01 ki LSI ZONEfSYSTEM M OffTConfJCS Z-1 OffJConf./CS Z-2 Off. 3-6, CS Z-2 Off.3^,CS z-3 Lunch/Lounge Z-3 Z-4 Z-4 Lunch/Lounge nterlor interior ... . — — r< E \\ AREA BASIS COND. AREA (SF) 827 1.33- 1,067 .... CFMPERSF 0.15 0.15 0.50 0.15 . ... ... MM. CFM (B»C) 124 200 934 559 OCCUPANCY BASIS NO. OF PEOPLE $ /•$ ?5-7 •37 ... . CFM PER PERSON ;<- l< f5" /^ MIN. CFM <E*F) 120 Total TOW Total ***Total r * REQ'D ! O.A. (MAX OF DORB) 124 124 200 200 53J 534 560 559 DESIGN OUTDOOR AIR CFM 124 124 200 200 534 534 559 559 -- VAV MIN. RATIO .... - TRANS- FER AIR ... I — ;_ Minimum Ventilation Rate per Section 121, Tabte1-F, i_ Based on Expe<^ Number of Occupants or at teart 50% of CH»pt»r 10 1M7 UBC Occupant Density. Mu«t b* greater th»n o' «flu»f to M, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Cj Mu« be greater than or equal to (H minus t). and. for VAV, greater than or equal to (H-J). Er*gypro2.i eyenergySoft User Number 1712 Jot>Nucnoernn-oi pagan on? EsGil Corporation In Partnership witft government for Quitting Safety p APPLICANT p PLAN REVIEWER P FILE DATE: February 21, 2001 JURISDICTION: Carlsbad PLAN CHECK NO.: 01-0094 SET: II PROJECT ADDRESS: 2450 Impala Drive PROJECT NAME: Office T.I. for Sensa The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Stephen G. Brown 6315 Muirtands Dr., San Diego, CA 92037 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Stephen Brown (djrti Telephone #: (858) 459-8050 Date contacted: ife»/oi (by: to-) Fax #: Mail v—Telephone-/ Fax In Person REMARKS: By: Bert Domingo Esgil Corporation • GA • MB EJ Enclosures: PC 2/12/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego,-California 92123 4 (858)560-1468 + Fax (858) 560-1576 Carlsbad 01-O094 II February 21, 2001 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 01-0094 PROJECT ADDRESS: 2450 Impala Drive SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 2/12/01 February 21, 2001 REVIEWED BY: Bert Domingo FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? Q Yes Q No Carlsbad 01-0094 II February 21, 2O01 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Please see items 4 & 5 below. 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24), which adopts the 1997 UBC, UMC and UPC and the 1996 NEC. Please show all the codes on the plans as shown above. 4. Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 106.3.3. 5. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building will comply. Section 3405. Items 4 & 5 are needed information on the plan or show code justification for exceeding the allowable area in Table 5 B and structural framing systems with complete calculations. 6. On the first sheet of the plans indicate: • Present and proposed occupancy classifications of the remodel area, 14. Doors should not project more than 7 inches into the required hallway width when fully opened, nor more than one-half of the required corridor width when in any position. Section 1004.3. Carlsbad 01-0094 II February 21, 20O1 • PLUMBING, MECHANICAL AND ENERGY CORRECTIONS 4 JURISDICTION: Carlsbad DATE: 2/20/01 * PLAN REVIEW NUMBER: 01-0094 SET: II 4 PLAN REVIEWER: Glen Adamek 2. Correct the note #29 on sheet TS1 of the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E. Not "That exceeds current UBC?" PLUMBING (1997 UNIFORM PLUMBING CODE) 3. Please show the elevation of the upstream sewer manhole cover. As per UPC, Section 710.0, provide backwater valves on all building drains which serve plumbing fixtures with flood rim elevations below the public or private upstream manhole rim elevations. Only fixtures with flood rim levels below the public upstream manhole rim elevation may flow through a backwater valve. No response found? • MECHANICAL (1997 UNIFORM MECHANICAL CODE) 5. It is assumed from the response of "NA" that no Class I, II, or III-A liquids are used in any amount in the building. If so clearly not on the plans: "No Class I, II, or III-A liquids are used in any amount in the building." 6. It is assumed from the response of "NA" that no combustible dust is produced or used in the building. If so clearly not on the plans: "No combustible dust is produced or used in the building." 7. Detail overflow (secondary) condensate discharge from air conditioning units that are in a ceiling space to readily observed locations. UMC Section 1105.12. The float switch called out on sheet M.4 is not acceptable. The liquid sensor must be a non-mechanical switch. Or, provide the required secondary condensate pan and drain. Please correct. Carlsbad O1-O094 II February 21, 2001 • ENERGY CONSERVATION 12. The MECH-3 form for the new HVAC units do not include the required Occupancy Dated ventilation calculations. Not corrected, the Columns '£', *F', and 'G' are blank on the MECH-3 forms. Please complete. 14. On the plans clearly show the wall insulation locations, thickness, and R-values, as per the energy design. Not found on the plans? 16. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131(d). The automatic shut-off controls are not listed on the LTG-1 part 1 of 2 and the proposed systems are not clear? 17. Show bi-level lighting controls as per Title 24, Part 6, Section 131(b). Sheets E4 and E5 have not been corrected. 18. Show the daylit areas and required daylit area lighting controls for lighting in daylit areas. Title 24, Part 6, Section 131(c). Sheets E4 and E5 have not been corrected. Note: controlling all the light fixtures in the daylit area on a single switch done not comply. Also, the plans show some rooms over 250 square feet in area showing all switching controls controlling light fixtures both inside and outside the daylit areas. Please correct. 20. The corrected, completed and signed PERF-1, ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans. The LTG-1 forms on sheet E-1 are not complete (Mandatory Automatic Controls section is blank?) and the PERF- 1 Part 2 of 3, PERF-1 Part 3 of 3, ENV-1, and MECH-1 forms are missing from the plans? Note: If you have any questions regarding this plumbing, mechanical and energy plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad O1-0094 II February 21, 2O01 * ELECTRICAL PLAN REVIEW • 1996 NEC • JURISDICTION: CARLSBAD DATE: 02/20/01 • PLAN REVIEW NUMBER: 01-0094 • PLAN REVIEWER: MORTEZA BEHESHTI 2. Show or note on the plans the method used to limit fault currents on branch circuits. Show the fuse letters if used to limit fault current (i.e., JJN, AST, LPN). JUSTIFY THE 18 KAIC RATING SHOWN FOR NEW "HVI-B" PANEL. 3. Show the building main disconnecting means. NEC 225-31 SHOW GROUPING OF SERVICE DISCONNECTING MEANS. NEC 230-72(a) Note: If you have any questions regarding this electrical plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation. Thank you. EsGil Corporation 2n Partnership with government for Wuihting Safety DATE: January 18, 20O1 a APPLICANT Q ^ORJsT^ JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 01-OO94 SET: I PROJECT ADDRESS: 2450 Impala Drive PROJECT NAME: Office T.I. for Sensa The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: a. t>i e G o , °A Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Src-^s*^ #JMA>^ Telephoned L&3$) HS^.tfo^*) (^ Date GGOtaeted: i (2-1/01 (by: ^ ) Fax #: Mail "Telephone"" Fax In Person REMARKS: By: Bert Domingo Enclosures: Esgil Corporation • GA BMB Q EJ D PC 1/11/01 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + SanDiego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 Carlsbad 01-0094 January 18, 20O1 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 01-0094 OCCUPANCY: B TYPE OF CONSTRUCTION: V N ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: January 18, 20O1 JURISDICTION: Carlsbad USE: Office ACTUAL AREA: 26100 SQ. FT. STORIES: TWO HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESG1L CORPORATION: 1/11/01 PLAN REVIEWER: Bert Domingo FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked UP list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw.dot Carlsbad 01-0094 January 18, 2O01 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24), which adopts the 1997 UBC, UMC and UPC and the 1996 NEC. 4. Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 106.3.3. 5. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building will comply. Section 3405. 6. On the first sheet of the plans indicate: • Present and proposed occupancy classifications of the remodel area, • The occupant load of the remodel area(s). Carlsbad 01-0094 January 18, 2001 7. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. 8. Note on the plans: "All interior finishes must comply with Chapter 8 of the UBC". Specify "Class flame spread rating (minimum) for 9. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.). Section 708. 10. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 708. 11. Specify lever-type hardware for passage doors on floors accessible to the disabled. Title 24. 12. Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size). Show in this analysis the occupant load of each area, the general exit flow patterns (by using arrows), accumulated occupant loads and required exit widths. 13. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge." In lieu of the above, in a Group B, F, M or S occupancies, you may note "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." This signage is only allowed at the main exit. Section 1003.3.1.8. 14. Doors should not project more than 7 inches into the required hallway width when fully opened, nor more than one-half of the required corridor width when in any position. Section 1004.3. Carlsbad 01-0094 January 18, 2001 • MISCELLANEOUS 15. Please remove the note referring to San Diego City under Plan Notes on sheet A1. 16. Where is detail 1/1 as cross referenced on sheet A1. 17. Please show the area of the 1st floor and 2nd floor separately and the warehouse. + PLUMBING, MECHANICAL AND ENERGY CORRECTIONS * JURISDICTION: Carlsbad DATE: 1/22/01 4 PLAN REVIEW NUMBER: 01-0094 SET: I «• PLAN REVIEWER: Glen Adamek 1. Each sheet of the plans must be signed by the person responsible for their preparation. Business and Professions Code. The licensed designer must sign each sheet of the plans. 2. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. Correct the note #29 on sheet TS1 as per the "Exempt Amounts" in UBC, Tables 3-D, and 3-E. a) Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials. Provide the material safety data sheets (MSDS). b) Clearly show the amounts of each type of hazardous material to be stored and in use. c) Clearly show where in the buildings each type of hazardous material is being stored or used. PLUMBING (1997 UNIFORM PLUMBING CODE) 3. Please show the elevation of the upstream sewer manhole cover. As per UPC, Section 710.0, provide backwater valves on all building drains which serve plumbing fixtures with flood rim elevations below the public or private upstream manhole rim elevations. Only fixtures with flood rim levels below the public upstream manhole rim elevation may flow through a backwater valve. 4. Correct the water line sizing calculations. The Maximum Fixture Units Allowed in the Table on sheet P3 do not match the values from the UPC, Table 6-5. If Appendix A sizing is to be used then provide data to show the Ultra Low Flush, Flush Valve Water Closets will operate on only 15 psi as used in the sizing calculations. Carlsbad 01-0094 January 18, 20O1 • MECHANICAL (1997 UNIFORM MECHANICAL CODE) 5. In Groups B, F, M, and S Occupancies, or portions thereof, where Class I, II, or lll-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour. Such mechanical exhaust shall be taken from a point at or near the floor. UBC, Section 1202.2.2. 6. "Equipment, machinery or appliances which generate finely divided combustible waste or which use finely divided combustible material shall be equipped with an approved method of collection and removal." UBC, Section 306.8 7. Detail overflow (secondary) condensate discharge from air conditioning units that are in a ceiling space to readily observed locations. UMC Section 1105.12. Provide data and detail the "Overflow Prevention Switch" called out on sheet M.4? 8. Provide smoke detection in supply air duct of 'air-moving system1 for required shut-off for smoke control as per UMC, Section 608 and also see Section 203. • ENERGY CONSERVATION 9. The LTG-2 form shows 14,700 square feet of only Office use conditioned space, but the plans show Corridors, Hallways, Stairways, Restrooms, Storage Room, Support Areas, and Lunch Rooms (Dining Area) use conditioned areas. Please correct the allowed lighting levels. 10. The plans do not show the existing first floor level is existing non- conditioned area as per the Energy Pro energy design. Please correct. 11. No MECH-3 forms for the existing package HVAC units to show the ventilation rates comply with the energy standards for the proposed changes. Please correct. 12. The MECH-3 form for the new HVAC units do not include the required Occupancy Dated ventilation calculations. Please correct. 13. The LTG- forms show the conditioned floor area to be 14,700 square feet and the PERF-1 form shows the conditioned floor area to be 6,950 square feet. Why the difference? 14. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. Carlsbad 01-0094 January 18, 2O01 15. Provide plans, calculations and worksheets to show compliance with current energy standards. 16. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 17. Show bi-level lighting controls as per Title 24, Part 6, Section 131(b). 18. Show the daylit areas and required daylit area lighting controls for lighting in daylit areas. Title 24, Part 6, Section 131(c). 19. Detail required exterior lighting controls. "Exterior lighting controlled from a lighting panel within the building shall be controlled by a directional photocell or astronomical time switch that automatically turns off exterior lighting when daylight is available." 20. The corrected, completed and signed PERF-1, ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans. 21. The Documentation Author and the Principal Lighting Designer must sign the corrected LTG-1 form. 22. The Documentation Author, the Principal Envelope Designer and the Principal Mechanical Designer must sign the corrected PERF-1 form. 23. Complete energy plan check will be done when complete corrected energy designs are provided. Note: If you have any questions regarding this plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 01-O094 January 18, 2001 «• ELECTRICAL PLAN REVIEW • 1996 NEC * JURISDICTION: CARLSBAD DATE: 1/19/1 * PLAN REVIEW NUMBER: 01-0094 4 PLAN REVIEWER: MORTEZA BEHESHTI 1. On the single line diagram there is a 400 ampere meter main section with panels and a 30 KVA transformer shown. Is this section also being installed? Please clarify. NEC 215-5. 2. Show or note on the plans the method used to limit fault currents on branch circuits. Show the fuse letters if used to limit fault current (i.e. , JJN, A3T, LPN). 3. Show the building main disconnecting means. NEC 225-31 4. Show the grounding system required for the service. NEC 250-80, 81 5. Show the grounding electrode conductor size and wire type (AL/CU). NEC 250-94. 6. Submit load calculations. Include long continuous loads (LCL) and the largest motor loads. NEC 220. 7. Show or identify new loads proposed for the existing equipment. 8. Show the main service size (amperage rating) and the total load demand on the existing service. 9. Specify the wiring method you intend to use for this project (i.e., EMT, Metal Flex, NMCetc.). NEC110-3(a)and(b) 10. Show on the plan the location of the existing service, NEC 110-16, 230-2. 11. Show the location of all panels and transformers. See comment #1. NEC 110- 16,240-24,300-21. 12. Provide GFI protected receptacle(s) within 25 feet of HVAC equipment. NEC 210- 8(b)2&210-63 13. Detail the installation of the junction box shown for the forklift charger. NEC 380-8 Carlsbad 01-0094 January 18, 2001 14. Provide multiple switch light controls in the office area so that the lighting can be reduced by one half in a uniform pattern. The switches must be located within sight of the lights which they control. CBC Title 24, Sec 131 a-b 15. Specify exit signs as being self-luminous or having a second source of power (battery or generator). UBC 1003.2.8.2 and NEC 700-16. 16. Specify a second source of power for the emergency illumination (battery or generator). UBC 1003.2.9.2 & NEC 700-16. 17. Each commercial building and each commercial occupancy accessible to pedestrians shall be provided with at least one outlet in an accessible location at each entrance to each tenant space for sign or outline lighting system use. NEC 600-5(a) 18. Note the following requirements on the prints for panelboards supplying fire alarm equipment: Lockable cover, identified circuit breaker (red), and a breaker "lock-off* device to be installed. 19. Note on the single line diagram that all service disconnect devices shall be labeled as a "Service Disconnecting Means". NEC 230-70(b) 20. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures will be identified as series-rated and labeled in accordance with NEC 110-22" and " The overcurrent devices shall be AIC rated per manufacturers, labeling of the electrical equipment". 21. Note that pull-section taps are factory installed, field installed per factory specifications (available at the site), or to be certified by a third party (NRTL certified) testing laboratory. Note: If you have any questions regarding this electrical plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 01-0094 January 18, 2001 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation. Thank you. Carlsbad 01-OO94 January 18, 20O1 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 01-0094 DATE: January 18, 2001PREPARED BY: Bert Domingo BUILDING ADDRESS: 2450 Impala Drive BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V N BUILDING PORTION Office Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 26100 26100 26100 cb Valuation Multiplier 28.00 3.60 1.80 By Ordinance 1994 UBC Building Permit Fee ^ Reg. Mod. VALUE ($) 730,800 93,960 46,980 871,740 $3,127.78 1994 UBC Building Permit Fee Type of Review: Repetitive Fee Repeats Complete Review D Other D Hourly Structural Only Hour(s) Esgil Plan Review Fee $2,033.05 $1,626.44 Comments: Sheet 1 of 1 macvalue.doc DATE://2-^/01 BUILDING ADDRESS: PROJECT DESCRIPTION: City of Carlsbad Public Works Engineering BUILDING PLANCHECK CHECKLIST PLANCHECK NO.: CB ASSESSOR'S PARCEL NUMBER:EST. VALUE: /*<7 T&v ENGINEERING DEPARTMENT.^ APPROVAL /^ ) DENIAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. Ok Right-of-Way permit is required prior to construction of the following improvements: Please/see/the attached report of deficiencies marked wjtn D.Make necessary corrections to plans or specifreattons for compliance with applicable codes and standards. Subrrjit-eoirected plans and/or specifications to this officelor review. By By:Date: By: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERI Dat ATTACHMENTS D Dedication Application C Dedication Checklist u Improvement Application D Improvement Checklist . Q Future Improvement Agreement 0 Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application [] Right-of-Way Permit Submittal Checklist and Information Sheet D Sewer Fee Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: KATHLEEN M. FARMER City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad. CA 92008 Phone: (760) 602-2741 CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: CA 920O8|-7314 • (76O) 6O2-2720 * FAX (76O) 602*8592 BUILDING PLANCHECK CHECKLIST 1ST iRD SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow B. Existing & Proposed Structures C. Existing Street Improvements D. Property Lines E. Easements F. Right-of-Way Width & Adjacent Streets G. Driveway widths H, Existing or proposed sewer lateral I. Existing or proposed water service J. Existing or proposed irrigation service CD CD 2. Show on site plan: A.Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: A. Site address B. Assessor's Parcel Nu C. Legal Description For commercial/industrial builctffigs and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION mWORDOOCStCHKLSTWuUIng «»*•* CM* Form (OwwriOjtoc R*v. 7/1*00 ST ND rd BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE D D 4a. Project does not comply with the following Engineering Conditions of approval for Project No. _ D n 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS D D D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15.000. pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 34" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS D D D 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:\WOftftDOCS\CHKLST\BuMlna PUnctaCk CW»t Form (RIDDLE • HARVEY 7- 12-00).dOC BUILDING PLANCHECK CHECKLIST I ST 2NO 3rd checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $280 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Neighborhood Improvement Agreement will include the following: D D 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: D D D 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. D D C3 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). C] G n 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: D D D 7c- Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) mWOfUWOCStCHKLSTOuUdinB PtencMCfc Cktat Forni (RIDDLE - HARVEY 7-12-00).doC BUILDING PLANCHECK CHECKLIST A sr 2ND 3RD D D Q 7d .No Grading Permit required. Q n CD 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS D D D 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: G D 9- INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: D D D 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. D D D 11. Q Required fees are attached Q No fees required WATER METER REVIEW D D D 12a- Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. Rw.7/1Wn BUILDING PLANCHECK CHECKLIST 1ST )ND >RD • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand, (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) Alt irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled T, and potable water is typically a circled "W". The irrigation service should look tike: STA 1+00 Install 2" service and 2. 3. 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water HWWTODOCSVCHKLSTOUUng PtmftM* CUM Fexm fG*nric).doc BUILDING PLANCHECK CHECKLIST ST 9ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. D CD 12c. Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. D D D 13. Additional Comments: H:\WOWXXJC9eHKLS7WuMlrQ PUnchw* CkM Forni (G«rte).*x: D ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant. Calculation based on building plancheck plan submittal. Address: cX-LT/5D ^ Prepared by: oTN EDU CALCULATIONS: Types oTHJse: Types of Use: ADT CALCULATIONS: C -CG-*»— fc*^*-*'^— c TypeVfefUse: Types of Use: -^-N-fp^ Wr,\ip £> Bldg. Permit No. V\^~? I'/ Date: S/^[/T)l Checked by: ( C List types and square footages for all uses. ^ Sq. Ft./Units: ^ Sq. Ft./Units: List types a/id square footages for all uses. Sq. Ft./Units: -^ Sq. Ft./Units: CJ&O/OTjYY Date: EDU's: pi -(pb EDU's: ADT's: // ^3 ADT's: FEES REQUIRED: WITHIN CFD: D^ES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1. PARK-IN-LIEU FEE :EE/UNIT: PARK AREA & #: X NO. UNITS: 2. TRAFFIC IMPACT FEE ADT's/UNITS: )GE AND THOROU ADT's/UNITS: ILITIES MANAGEF UNIT/SO. FT.: . SEWER FEE EDU's: X FEE/ADT:-• JGHFARE FEE (DIST. : X VIENT FEE ZONE: X #1 DIST. #2 FEE/ADT: FEE/SO. FT. /UNIT: DIST. #3 ) * = $ FEE/EDU: BENEFIT AREA: EDU's: f FEE/EDU: D 6. SEWER LATERAL ($2,500) D 7. DRAINAGE FEES PLDA_ ACRES: = $. = $. = $ o . HIGH /LOW FEE/AC:= $ D 8. POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION WonflDocsWII>fornw\FM Calculation WorfcshMt I Of 2 Rev. 7/14KK) ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9. RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES*: $ *NOTE: This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits. 2 of 2 WonflDocs\Mlsforms\FTC Calculation Wortwhwt Rev. 7/14/00 7 TO o oto a CO \ \a V PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB O\Address Planner Paul Godwin APN: \mrn^flLJ Phone (7601 602-4625 Type of Project & Use:_ Zoning: PAQ T\ CFD fin/niiti Circle One General Plan: P\ JDS/ .Date of participation: Net Project Density: DU/AC _ Facilities Management Zone: J5 Remaining net dev acres: (For non-residential development: Type of land used created by this permit: } Legend:Item Complete Environmental Review Required: DATE OF COMPLETION: YES Item Incomplete * Needs your action NO A TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. YES NO )("_ TYPE DATE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: | | Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO CA Coastal Commission Authority? YES NO If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): - Coastal Permit ^Determination Form already completed?, If NO, complete Coastal-Permit Determination Form1 now. Coastal Permit Determination Log #:' ' YES NO Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. H:\ADMIN\COUNTER\BldgPlnchkRevChklst I I Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor's parcel number. Zoning: 1 . Setbacks: Front: Interior Side: • Street Side: Rear: I I 2. Accessory structure Front: Interior Side: Street Side: Rear: Structure separation Required Required Required Required setbacks: Required Required Required Required : Required Shown Shown Shown Shown Shown Shown Shown Shown Shown I I 3. Lot Coverage:Required Shown 4. Height:Required Shown 5. Parking: Spaces Required Guest Spaces Required Additional Comments Please $\r\ou Uou Shown Shown f o'g-f flaouo'jed- gflui|fl/VK/n 3|"? |0l •* pao:>all til/flC OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Wrf j.Q&JM/V^ DATE 3/"7/Q/ H :\ADM1 N\CO UNTER\BldgPlnchkRevChklst Fire Department 010094 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report: 02/13/2001 Fire Prevention (760) 602-4660 Building Plan Reviewed by: Name: Address: LARRY WHARTON 639 BISON CT City, State: EL CAJON CA 92019 Plan Checker: Job Name: SENSABldg. Job#: 010094 Job Address: 24§jr Impala Drive Bldg#: CB010094 Ste. or Bldg. No. Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submitted; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review FD Job # 1st 2nd 3rd 010094 FDFile* Other Agency ID Carlsbad Fire Department Name: LARRY WHARTON Address: 639 BISON CT City, State: EL CAJON CA 92019 less Faraday Ave. Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Date of Report: 02/13/2001 Reviewed by: Plan Checker °10094 Job Name: SENSA Bidg. Job Address: 2459 Impala Drive Ste. or Bldg. No. Approved per impact letter. Follow directions in report and have on site for inspections. £#r1sbad Fire Department 010094 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Building Plan Date of Report: 01/23/2001 Reviewed by: Name: LARRY WHARTON Address: 639 BISON CT City, State: Plan Checker: Job Name: SENSA Bidg. Fire Prevention (760) 602-4660 ELCAJONCA 92019 Job#: 010094 Job Address: 2450 Impala Drive Bldg #: CB010094 Ste. or Bldg. No. D Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1 st ?nd 3rd FDJob* 010094 FDFile# Other Agency ID Requirements Category: Building Plan Requirement: Pending 05.01 Project Data Provide complete address and suite designation. Provide building construction information indicating occupancy classification, type of construction, number of stories, aggregate square footage, occupant load, and description of intended uses. Requirement: Pending 05.14 Provide Technical Report To determine the acceptability of technologies, processes, products, facilities, materials and uses attending the design, operation or use of a building or premises subject to the inspection of the department, the Chief is authorized to require the owner or the person in possession or control of the building or premises to provide, without charge to the jurisdiction, a technical opinion and report. The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety properties of the design, operation or use of the building or premises and the facilities and appurtances situated thereon, to recommend necessary changes. Requirement: Pending 05.33 Plan Revisions Please submit 3 sets of corrected plans directly to the Building Department for routing to the appropriate departments. Page 1 01/23/01 Klausbruckner & Associates 4719 Palm Avenue La Mesa, CA 91941 CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Tel: (619) 466-6860 Fax:(619)466-6233 February 7, 2001 Martin Aguilera Carlsbad Fire Department 1635 Faraday Ave. Carlsbad, CA 92008 RE: Sensa - Carlsbad, CA Negative Impact Letter Dear Martin: On behalf of the owners, we are requesting that the requirement for a technical report be waived. It is my understanding that the fire department at times accepts a "negative impact' letter, which allows for a technical report waiver. It is our understanding that the shell building was recently built to the 1997 Edition of the Uniform Building and Fire Codes. Therefore the only issues which may arise are from the proposed tenant improvements to the facility. The proposed Sensa facility will be used for the assembly and storage of pens and pen parts. The proposed area of storage is approximately 2000 square feet (Attachment #1). The product is aluminum pens in plastic casing in cardboard boxes; there is no foam packaging used in this storage. Based on a review of the materials, the following is a breakdown of the commodity stored greater than 6 feet: Non-Group A Plastic Parts: Box, Aluminum Pen with Silicone Grip - 93.8-87.2 grams Group A Plastic Parts: SAN Box/Casing - 62.1 grams As shown above the percent by weight of Group A Plastics exceeds 15% by weight (Attachment #2), and therefore the material is considered high hazard commodity. Based on Table 81-A, only an automatic suppression system is required (Attachment #3). The method of storage is shelf storage and solid pile/palletized storage to 10 feet. Therefore based on UFC 8103,2.2, the protection shall be in accordance with UFC 81-1 (NFPA 231 with UFC Amendments). The 1995 Edition of NFPA 231 has been used for this analysis, since the UFC Amendments to NFPA 231 does not affect this analysis: Method of Storage: Maximum Storage Height: Maximum Ceiling Height: Design Density Required: Existing Design Density: Shelf Storage 10 feet 28 feet 0.48/2500 (Attachment #4) 0.45/3000 Sensa - Carlsbad, CA February 7,2001 Page 2 of 2 Please note that NFPA 231 only addresses 25 foot ceiling heights for storage of materials up to 12 feet. Therefore a maximum ceiling height of 25 feet, as opposed to 28 feet, was used in this analysis. Please note that the above design density is required to be provided for the area directly above the storage area and 15 feet beyond, or to a permanent partition, as required by UFC 8102.2 (Attachment #5). The sprinkler contractor must verify that the required design density of 0.48/2500 is met over the storage area and 15 feet beyond the storage area (or to a permanent partition). Other Miscellaneous Storage: In addition to the above high piled storage, the owners intend to store a few "display" products. These display products are exposed polyurethane foam. The owners agree to store these materials to a maximum height of 5 feet. Based on NFPA 231 Table 7-2.2, an ordinary Hazard Group 2 sprinkler system is required (0.2/1500) (Attachment #6). The existing system is 0.45 gpm per square foot over a design area of 3000 square feet, which meets the requirements for Class IV commodity. In conclusion, we would request that the requirement for a technical report be waived based on the limited hazards within the facility. Your consideration in this matter is greatly appreciated. If you have any questions, or need additional information, do not hesitate to call me. Sincerely, Elley Klausbruckner, P.E. Klausbruckner & Assoc. By way of my signature, I agree to the above-mentioned storage conditions/restrictions. Daniel Kostrikin - Sensa ATTACHMENT^ 5'- lO'-O' H 10/10"d 2W-1 ATTACHMENT #2 1997 UNIFORM FIRE CODE 30. •a I fi "5a> 30 25 20 15 10 5 n Classifyas Class I, II or III commodity Classify as Class IV commodity Classify ashigh-hazardcommodity - -»• 10 15 20 25 Percent by Weight of Unexpended Plastic4 FIGURE 8101.4-A— MIXED COMMODITIES1'2 (Sea Section 8101.4.3) 1This table is intended to determine the commodity classification of a mixed commodity in a package, carton or on a pallet when plastics are involved. 2The following is an example of how to apply the table: A package containing a Class III commodity has 12 percent Group A expanded plastic by volume. The weight of the unexpanded Group A plastic is 10 percent. This commodity is classified as a Class IV commodity. If the weight of the unexpanded plastic is increased to 14 percent, the classification changes to a high-hazard commodity. ,„ , , Volume of plastic in pallet load^Percent by volume = 4Percent by weight = Total volume of pallet load, including pallet Weight of plastic in pallet load Total weight of pallet load, including pallet ATTACHMENT #3 1997 UNIFORM FIRE CODE TABLE 81-A—GENERAL FIRE-PROTECTION AND LIFE-SAFETY REQUIREMENTS COMMODITYcuss I-IV High hazard SIZE OF HIGH-PUD STORAGEAREA1 (tquara tot) (S*» S*t-•MtltttiMid 1102.4) «o.omr«m* 0-500 501-2,500 2,501-12,000 Public accessible 2,501-12,000 Nonpublic accessible (Option 1) 2,501-12,000 Nonpublic accessible (Option 2) 12,001-20,000 20,001-500,000 Greater than 500,000s 0-500 501-2,500 Public accessible 501-2,500 Nonpublic accessible (Option 1) 501-2,500Nonpublic accessible (Option 2) 2,501-300,000 300,001 -500,000s-9 ALL STORAGE AREAS (Si* Swtton* 1102, 1103 and 1104)* Automatic Fb*-ixHngutaMng SyitunlSHStcttwi 1102,4) NR1 NR1 Yes Yes NR1 Yes Yes Yes NR1 Yes Yes NR1 Yes Yes Fln-d*ttetlonSyitan (SHSection 1102.5) NR Yes NR NR Yes NR NR NR NR NR NR Yes NR NR BuildingAcc*u(S«tS«tk»nI10I.I) NR5 NR5 NRS NR5 Yes Yes Yes Yes NR5 NR5 NR5 Yes Yes Yes Smok* widH*tt RtmivilISftSMtiofi1102.7) NR NR NR NR Yes * Yes' . Yes ' Yes NR NR NR Yes Yes Yes Curtain Bowdi(S»»Siettofl (102.1) NR6 NR6 NR6 NR6 Yes Yes • Yes Yes NR6 NR6 NR6 Yes Yes Yes SMIHOMVifmintfSfe-Ooni (S« S«.tten 1102.1) NR NR NR NR Yes Yes Yes Yes NR NR NR Yes Yes Yes SOLO-PILED STORAGE, SHELF STORAGE ANDPALLETIZED STORAGE (SMStction 11013) Mitimum PittWiun- tton'(hil) Muunim PtmiuMt Stung* Htloht* M » 3041 (« mm NR 100 100 100 100 100 ,100 100 50 50 50 50 50 50 NR 40 40 40 307 40 40 40 NR 30 30 20 30 30 MuhwiiPIt Vohint (cubic fttff x 0.0213 (M M> NR 100,000 400,000 400,000 200,000 400,000 400,000 400,000 NR 75,000 75,000 50,000 75,000 75,000 NR = Not required. 1 When fire sprinklers are required for reasons other than Article 81, the portion of the sprinkler system protecting the high-piled storage area shall be designed and installed in accordance with Sections 8103 and 8104. 2For aisles, see Section 8102.10. 3Piles shall be separated by aisles complying with Section 8102.10. 4Forsiorage in excess of the height indicated, special fire protection shall be provided in accordance with footnote 8 when required by the chief. See also Articles 79 and 88 for special limitations for flammable and combustible liquids and aerosols. 5Section 902.2 shall apply for fire apparatus access. Curtain boards shall be installed as required by the Building Code. See UBC Section 906. 7For storage exceeding 30 feet (914 mm) in height, Option I shall be used. ^Special fire-protection provisions such as, but not limited to, fire protection of exposed steel columns; increased sprinkler density; additional in-rack sprinklers, without associated reductions in ceiling sprinkler density; or additional fire department hose connections shall be provided when required by the chief. "High-plied storage areas shall not exceed 500,000 square feet (46 451.5 m2), A two-hour area separation wall shall be used to divide high-piled storage exceeding 500,000 square feet (46 451.5 m2) in area. ATTACHMENT #4 231-10 GtNF.RAt. STORAGE 6-2.5 Water supply duration shall be in accordance with Table 6-2-5. Table 6-2.5 Duration (hours) Storage Height ft(m) Commodity Class Classes I, II, and III Class IV over 12 i3.7) up to 20 (6.1) over SO (6.1) up to 30 (9.1) 6-3 High-Expansion Foam. See Section 5-2. Chapter 7 Fire Protection for Plastic and Rubber Commodities—Spray Sprinklers 7-1* General. See Appendix B. 7-1.1* Plastics stored up to 30 ft (9.1 m) in heigh: pro- tected by spray sprinklers shall be in accordance with Chapter 7. The decision tree (Figure 7-1.1) shall be used to determine the protection in each specific situation. 7-1.2* Factors affecting protection requirements such as closed/open array, clearance between storage and sprin- klers, and stable/unstable piles, shall be applicable only to storage of Group A plastics. The factors contained in 7-2.1, A-7-2.1, and Appendix B shall be given serious consider- ation prior to determining the final protection require- ments. This decision tree also shall be used to determine protection for commodities that are not wholly Group A plastics but contain such quantities and arrangements of the same that they are deemed more hazardous than Class IV commodities. 7-1.3 Group B plastics a~nd free-flowing Group A plas- tics shall be protected in the same manner as a Class IV commodity. Storage 12 ft (3.7 m) or less in height shall be protected in accordance with N'FPA 13, Standard for the Installation of Sprinkler Systems, for Ordinary Hazard Group 2. 7-1.4 Group C plastics shall be protected in the same manner as a Class HI commodity. Storage 12 ft (3.7 m) or less in height shall be protected in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, for Ordinary Hazard Group 2. 7-2 Water Supplies. 7-2.1* The design of the sprinkler system shall be based on those conditions that routinely or periodically exist in a building that create the greatest water demand. TJiese .conditions include: (a) Pile height , / (b) Clearance (c) Pile stability (d) Array. 7-2.2* Design areas and densities shall be selected for the appropriate storage configuration from Table 7-2.2. 7-2.3 Where sprinkler protection has been designed for Group A plastics, at least 500 gpm (32 Us) shall be added to the density/area demand for hose streams. 7-2.4 Water supply duration (sprinkler demand plus hose streams) shall be 2-hour duration for 5 ft to 20 ft (1.5 m to 6.1 m) and 2'/'.>-hour duration for 20 ft to 25 ft (6.1 m to 7.6 m). Group A (See Note) Plastics Group B Class IV Group C Class III Expanded Nonexpanded Stable Table 7-2.2 Column E Unstable Table 7-2.2 Column 0 Stable Table 7-2.2 Column B Unstable Table 7-2.2 Column C Solid Unit Load Table 7-2.2 Column A Free-flowing Cartaned •* Expiosed Uns table Table 7-2.2 Class IV Sta Column A ble Cartoned Table 7-2.2 Column C Exposed Table 7-2.2 Column E NOTE: Cartons that contain Group A plastic material shall be permitted to be treated as Class IV commodiites under the following conditions: (a) there shall be multiple layers of corrugation or equivalent outer material that would significantly delay fire involvement of trie Group A plastic, and (b) the amount and arrangement of Group A plastic material within an ordinary canon would not be expected to significantly increase the fire hazard. Figure 7-1.1 Decision tree. 1995 Edition LARGE DROP SPRINKLERS/EARLY SUPPRESSION FAST RESK)XSF, cESFRi SPRINKLERS 231-11 Table 7-2.2 Storage Height n(m) 5(1.52) 12 (3.66) 15 (4.57) 20 (6. J ) 23 (7.62) RooPCeiling Height ft(m> 15 (4.57) 20 (6.10) 25 (7.62) 15 (4.57) 20 (6.10) 25 (7.62) 20 (6.10) 25 (7.62) 30 (9.14) 25 (7.62) 30 (9. 14} 35 (10.67) 30 (9.14) 35(10.67) 40(12.19) Densitj-Jffim/ft*) l(L/s)/ml] A OH-2 OH-2 OH-2 0.2 (0.14) 0.3 (0.20) 0.4 (0.27) 0.25(0.17) 0.4 (0.27) 0.45 (0.31) 0.3 (0.20) 0.45(0.31) 0.6 (0.41) 0.4 (0.27) 0.6 (0.41) N/A B OH-2 OH-2 OH-2 EH-2 0.6 (0.41) 0.8 (0.54) 0.5 (0.34) 0.8 (0.54) 0.9 (0.61) 0.6 (0.41) 0,9 (0.61) 1.2 (0.82) l* 0.75(0.51) ' 1.2 (0."82) N/A C OH-2 OH-2 OH-2 0.3 (0.20} 0.5 (0.34) 0.6 (0.41) 0.4 (0.27) 0.6 (0.41) 0.7 (0.48) 0.45 (0.31) 0.7 (0.48) 0.85 (0.58) 0.55 (0.37} 0.85 (0.58) ., . N/A D OH-2 OH-2 OH-2 EH-1 EH-2 0.45 (0.31) 0.3 (0.20) 0,45(0.31) 0.55 (0.37} 0.35 (0.24) 0.55 (0.37) 0.7 (0.48) 0.45 (0.3 [) -0.7 (0.48) N/A £ OH-2 OH-2 OH-2 EH-2 EH-2 0.7 10.48) 0.45 (0.31) 0.7 tO. 48) 0.85 (0.58} 0.55 (0.37) 0.85 (0.58) 1.1 (0.75) 0.7 (0.48) 1.1 (0.75) N/A NOTE 1: For Table 7-2-5. the design areas are a minimum of 2500 ft" (Exception: OH-2). NOTE 2: For closed array, areas shall be reduced from 300 fr 10 2000 ft". NOTE 3: Interpolation of densities/areas between storage heights shall be permitted. Interpolation of ceiling/roof heights shall not be permitted. NOTE 4: For density demands of 0.4 gpm/fr or greater, large orifice or extra-large orifice (ELOl sprinklers shall be used. NOTE 5: It is recommended that high-temperature raicd sprinklers be installed, since mosi tests upon which this standard is based used high-iemperaiurc rated sprinklers. NOTE 6: Column designations correspond to the configuration of plastics storage as follows: A: (1) Nonexpanded. unstable (2) Nonexpanded. stable, solid unit B: Expanded, exposed, stable C: (I) Expanded, exposed, unstable (2) Nonexpanded. stable, cartoned D: Expanded, cartoned, unstable E: (1) Expanded, cartoned, stable (2) Nonexpanded. stable, exposed NOTE 7: OH-2 « Density required for Ordinary- Hazard Group 2 occupancies. EH-1 * Density required for Extra Hazard Group 1 occupancies. EH-2 » DensJlj- required for Extra Hazard Group 2 occupancies as specified in NFPA IS. Standard for the hnlallation oj Sprittklrr Squirms. Hose streams shall be provided in accordance with 7-2.3. t, VA: Not applicable. 7-2.5* Where dry-pipe systems are used for Group A plastics, the operating area shall be increased by 30 percent without revising the density. Chapter 8 Fire Protection—Large. > Drop Sprinklers 8-1 General. 8-1.1 Large drop sprinklers shall be permitted for use with the hazards listed in Table 8-1. 8-2 Water Supplies. 8-2.1 Sprinkler water demand for large drop sprinklers shall be in accordance with Table 8-1. 8-2.2 A minimum of 500 gpm (32 Us) shall be added to the sprinkler demand for combined large and small hose stream demand. 8-2.3 Water supply duration shall be as indicated in Table 8-1. 8-3 Sprinkler System Design. 8-3.1 .All requirements contained in \FPA 13, Standard for the Installation of Sprinkler Systems, pertaining to large drop sprinklers shall apply. ) Exception: Where modified by this standard. | Chapter 9 Fire Protection—Early Suppression Fast Response (ESFR) Sprinklers 9-1* General. 9-1,1 ESFR sprinklers shall be permitted for the protec- tion of commodities in accordance with Table 9-1. 9-1,2* ESFR sprinklers shall be permitted for use in buildings with the following types of roof construction: (a) Smooth ceiling (b) Bar joist (c) Beam and girder (d) Panel. 1995 Edition ATTACHMENT #5 1997 UNIFORM FIRE CODE SECTION 8102 — GENERAL FIRE-PROTECTION AND LIFE-SAFETY FEATURES 8102.1 General. Fire-protection and life-safety features for high- piled storage areas shall be in accordance with Section 8102. Na- tionally recognized standards or guidelines, as applicable, are allowed to be used when approved. 8102.2 Extent and Type of Protection. Fire-detection systems, smoke and heat removal, curtain boards, small hose valves and sta- tions, and fire sprinkler design densities shall extend the lesser of 15 feet (4572 mm) beyond the high piled storage area or to a permanent partition. When portions of high-piled storage areas have different fire-protection requirements due to commodity, method of storage or storage height, the fire-protection features required by Table 81-A within this area shall be based on the most restrictive design requirements. 8102.3 Separation of High-piled Storage Areas. 8102.3.1 Separation from other uses. Mixed occupancies shall be separated per the Building Code. 8102.3.2 Multiple high-piled storage areas. 8102.3.2.1 General. The aggregate of all high-piled storage areas within a building shall be used for application of Table 81-A unless such areas are separated from each other by one-hour-rated fire-re- sistive walls constructed in accordance with the Building Code. Openings in such walls shall be protected by fire assemblies having a one-hour fire-protection rating. 8102.3.2.2 Multiclass high-piled storage areas. High-piled stor- age areas classified as Class I through Class IV not separated from high-piled storage areas classified as high hazard shall utilize the aggregate of all high-piled storage areas as high hazard for purposes of application of Table 81-A. To be considered as separated, one- hour-rated fire-resistive walls shall be constructed in accordance with the Building Code. Openings in such walls shall be protected by fire assemblies having a one-hour fire-protection rating. The requirements of Table 81-B shall be applied separately over each high-piled storage area for portions of storage areas having dif- ferent requirements due to commodity classification or storage height, 8102.4 Fire Sprinklers. Fire sprinkler systems shall be provided in accordance with Sections 8103 and 8104. 8102.5 Fire Detection. When fire detection is required by Table 81-A, an approved automatic fire-detection system shall be installed throughout the high-piled storage area. The system shall be monitored and shall be in accordance with Section 1007. 8102.6 Building Access. 8102.6.1 Access roadways. When building access is required by Table 81-A, access roadways shall be provided to within 150 feet (45.7 mm) of all portions of the exterior walls of buildings used for high-piled storage. EXCEPTION: When access roads cannot be installed due to topog- raphy, railways, waterways, nonnegotiable grades or other similar condi- tions, the chief is authorized to require additional fire protection as required for special hazards in Section 1001.9. Specifications for fire apparatus access roads shall be in accord- ance with Section 902.2. 8102.6.2 Access doors. 8102.6.2.1 General. When building access is required by Table 81-A, fire department access doors shall be provided in accordance with Section 8102.6.2. Access doors shall be accessible without the use of a ladder. ATTACHMENT #6 GENERAL INFORMATION 13-9 Cellulose Nitrate Motion Picture Film; N FPA 58, Standard for the Storage and Handling of Liquefied Petroleum Gases; NFPA 231, Standard for General Storage; NFPA 231C, Standard for Rack Storage of Materials; NFPA 231D, Standard for Storage of Rub- ber Tires; NFPA 231E, Recommended Practice for the Storage of Baled Cotton; NFPA 231F, Standard for the Storage of Roll Paper; NFPA 232, Standard for the Protection of Records; and NFPA 409, Standard on Aircraft Hangars. 1-4.7.4.2 Miscellaneous storage as defined herein shall be clas- sified as to occupancy group in accordance with Table 1 -4.7.4.2. 1-4.7.4.2.1 The commodity classifications and storage characteristics in Table 1-4.7.4.2 shall be as defined in NFPA 231, Standard for General Storage, and NFPA 231C, Standard for Rack Storage of Materials. 1-5 Abbreviations. The standard abbreviations in Table 1-5 shall be used on the hydraulic calculation form. 1-6 Level of Protection. 1-6.1 A building, where protected by an automatic sprin- kler system installation, shall be provided with sprinklers in all areas. Exception: Where specific sections of this standard permit the omission of sprinklers. 1-6.2 Limited Area Systems. When partial sprinkler sys- tems are installed, the requirements of this standard shall be used insofar as they are applicable. The authority having jurisdiction shall be consulted in each case. Table 1-4.7.4.2 Occupancy Group Classification for Miscellaneous Storage 12 ft (3.7 m) or Less in Height*t Group A Plastics «.' ' * ' Height Ceiling of Clearance to Storage Top of Storage To 5 ft No limit Over 5 ft to 10 ft To 5 ft Over 5 ft to 10ft Over 5 ft to 10 ft Over 5 ft to 8 ft Over 5 ft Over 10 ft W 12ft To 15ft Over 10 ft to 12 ft Over 5 ft Over 10 ft to 12ft To 5 ft Miscellaneous Tire Storage Piling Methods On floor, on side On floor, on tread or side Single, double, or multi-row racks Single row rack, portable Single row rack, fixed Rolled Paper Stored on End Heavy and medium weight Tissue Idle Pallet Storage Rack-R • Cartoned or Palletized-P Solid Expanded R-P OH-2 OH-2 R-P EH-1 EH-1 R-P EH-2 EH-2 P P EH-2 EH-2 R OH-2 OH-2 + 1 level + 1 level in rack in rack R-P EH-2** EH-2** * Height of Storage 5 ft to 12 ft To 5 ft To 5 ft 5 ft to 12ft 5 ft to 12 ft Height of Storage To 8 ft Over 8 ft to 12ft To 10 ft Height of Storage To 6 ft wooden To 4 ft plastic • ' Exposed • Solid Expanded OH-2 OH-2 EH-2 EH-2 EH-2 EH-2 OH-2 OH-2 + 1 level + 1 level in rack in rack EH-2" EH-2 Occupancy Group EH-1 OH-2 OH-2 EH-1 EH- lor OH-2 plus 1 level of in-rack sprinklers Occupancy Group OH-2 EH-1 EH-1 Occupancy Group OH-2 OH-2 Units: 1ft-0.3048m. "For storage heights or clearance to ceiling in excess of the above configurations, see N FPA 231, 231C. 231D, or 231F as appropriate. "For rack storage, OH-2 +1 Level in rack shall also be permitted. tThe design of the sprinkler system shall be based on the conditions that will routinely or periodically exist in the building creating the greatest water demand, '"eluding pile height and clearance. 1996 Edition 13-64 INSTALLATION OF SPRINKLER SYSTEMS Exception No. 3: Where pumps taking suction from a private fire service main supply sprinklers only, the pump need not be sized to accommodate inside and outside hose. Such hose allowance shall be considered in evaluating the available water supplies. Table 5-2.3 Hose Stream Demand and Water Supply Duration Requirements Hazard Classification Light Ordinary Extra Hazard Inside Hose (gpm) 0.50, or 100 0,50, or 100 0, 50, or 100 Total Combined Inside and Outside Hose (gpm) 100 250 500 Duration in Minutes 30 60-90 90-120 For SI L'niis: 1 gpm =s 3-785L/min. 5-2.3.1.2 The water supply for sprinklers only shall be determined either from the area/density curves of Figure 5-2.3 in accordance with the method of 5-2.3.2 or be based upon the room design method in accordance with 5-2.3.3, at the discretion of the designer. For special areas under con- sideration, as described in 5-2.3.4, separate hydraulic calcu- lations shall be required in addition to those required by 5-2.3.2 or 5-2.3.3. t 5-2.3.1.3 Regardless of which of the two methods is used, the following restrictions apply: (a) For areas of sprinkler operation less than 1500 sq ft (139 m2) used for Light and Ordinary Hazard Occupancies, the density for 1500 sq ft (139 m*) shall be used. For areas of sprin- kler operation less than 2500 sq ft (232 m2) for Extra Hazard Occupancies, the density for 2500 sq ft (232 m2} shall be used. (b)* For buildings having unsprinklered combustible concealed spaces (as described in 4-13.1.1), the minimum area of sprinkler operation shall be 3000 sq ft (279 m11). Exception No, 1: Combustible concealed spaces filled entirely with noncombustible insulation. Exception No. 2*: Light or Ordinary Hazard Occupancies where noncombustible or limited combustible ceilings are directly attached to the bottom of solid wood joists so as to create enclosed joist spaces 160 cuft (4.8 m3) or less in volume. Exception No. 3*: Concealed spaces where the exposed surfaces have a flame spread rating of 25 or less and the materials have been demonstrated to not propagate fire in the form in which they are installed in the space. (c) Water demand of sprinklers installed in racks or water curtains shall be added to the ceiling sprinkler water demand at the point of connection. Demands shall be bal- anced to the higher pressure. (See Chapter 6.) Water demand of sprinklers installed in concealed spaces or under obstructions such as ducts and cutting tables need not be added to ceiling demand. (d) Where inside hose stations are planned or are re- quired by other standards, a total water allowance of 50 gpm (189 L/min) for a single hose station installation or 100 gpm (378 L/min) for a multiple hose station installation shall be added to the sprinkler requirements. The water allowance shall be added in 50-gpm (189-L/min) increments beginning at the most remote hose station, with each increment added at the pressure required by the sprinkler system design at that point. (e) When hose valves for fire department use are attached to wet pipe sprinkler system risers in accordance with 4-13.21, the water supply shall not be required to be Density. (L/min)/m2 8.1 10.2 12.2 14.3 16.3 5000 465 4000 3000 2500 2000 1500 0.05 0.10 0.35 0.40 Density, gpnvtt2 Figure 5-2.3 AreVdensity curves. 1996 Edition NON-RESIDENTIAL CERTIFICATE: Non-Residential Land Owner, please read this option carefully and be sure you thoroughly understand the options before signing. The option you chose will affect your payment of the developed Special Tax assessed on your property. This option is available only at the time of the first building permit issuance. Property owner signature is required before a building permit will be issued. Your signature is confirming the accuracy of all information shown. Name of Owner Telephone Address Project Address Carlsbad. California 9200 City, State Zip Code City, State Zip Code Assessor's Parcel Number or APN and Lot Number if not yet subdivided by County Assessor. 0\- Building Permit Numbers) As cited by Ordinance No. NS-155 and adopted by the City of Carlsbad, California, the City is authorized to levy a Special Tax in Community Facilities District No. 1. All non-residential property, upon the issuance of a building permit, shall have the option to (1) pay the SPECIAL DEVELOPMENT TAX ONE- TIME or (2) assume the ANNUAL SPECIAL TAX - DEVELOPED PROPERTY for a period not to exceed twenty-five (25) years. Please indicate your choice by initialing the appropriate line below: OPTION ( 1 ): I elect to pay the SPECIAL TAX - ONE-TIME now, as a one-time payment . Amount of One-Time Special Tax: $ _ I G), ffiQ"\ _ . Owner's Initials OPTION (2): I elect to pay the SPECIAL DEVELOPMENT TAX ANNUALLY for a period not to exceed twenty-five^ (25) years. Maximum Annual Special Tax: $ _ / CO-**' _ - Owner's Initials _ . I DO HEREBY CERTIFY UNDER PENALTY OF PERJURY THAT THE UNDERSIGNED IS THE PROPERTY OWNER OF THE SUBJECT PROPERTY AND THAT I UNDERSTAND AND WILL COMPLY WITH THE PROVISIONS AS STATED ABOVE. Signature of Property Owner Title Print Name Date The City of Carlsbad has not independently verified the information shown above. Therefore, we accept no responsibility as to the accuracy or completeness of this information. _ Page 1 of 1 .JL^u 20:41 FAX 7606357890 Bob Wade- T-1G-1998 7: 12AM FROM SM 1 7H_CQNSULT ING-OUT 6194523907 P. 5 ra.IfflOO! NON-RESIDENTIAL CERTIFICATE:o»n«r.t*. en you- proparty. CA Oty CNy Court or** CHy of CtttoM. Ortfomta. t* dy 1. A Da«L^^ OPTION (1): OFTION<2): I Tw: t Y for »pMtod not to OWNER OP THE SUUBCT PRU»tHTi AND THAT I UNDERSTAND ***> VMU COMPLY WITH THE TM» J. NON-RESDENHAL CERTIFICATH 05/07/2001 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR01090 Building Inspection Request Line (760) 602-2725 Job Address: 2450 IMPALA DR CBAD Permit Type: PCR Parcel No: 2090412000 Lot#: 0 Valuation: $0.00 Construction Type: NEW Reference #: CB01-94 Project Title: SENSA-PARTITION MODIFICATION Status: ISSUED Applied: 04/17/2001 Entered By: JM Plan Approved: 05/07/2001 Issued: 05/07/2001 Inspect Area: Applicant: CALIGIURUTED 2450 IMPALA DRIVE CARLSBAD CA 92008 760-603-2120 01 CGP 02 272-00 Total Fees: $272.00 Total Payments To Date:$0.00 Balance Due: $272.00 Plan Check Revision Fee Additional Fees $272,00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition* of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Address (include Bldg/Suite *) FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. Plan Ck. Validated Date Business Name (at this address) J~ Legal Description Assessor's Parcel # Description of Work Lot No. Subdivision Name/Number Existing Use SO. FT. / T fttof Stories Unit No. Phase No. Total # of units Proposed Use # of Bedrooms it of Bathrooms Name Address City State/Zip Telephone # (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file e signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License It Address City Stete/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date {THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 19100] OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: FaBure to secure workers' compensation coverage Is unlawful, and shad subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), In addition to the cost of compensation, damage* aa provided for in Section 3706 of the Labor code. Interest and attorney's fees. SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I. as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sac. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but 1 have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): ___ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): __ PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans i$ accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA; An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued b^Jbebuilding Official unda the provisions of this Code shall expire by limitation and become null and void If the building or work authorized by such permit is not CQrtfojwpMwiOfin 180 days foBrn the date of such permit or If the building or work authorized by such permit is suspended or abandoned at any time after the work is comrn$ir)fe/.for/j5erjod of 180 ^SJftfJection 106.4.4 Uniform Building Code). PPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance EsGil Corporation In Partners/lip -ufitfi. government for Quitting Safety DATE: May 3, 2001 JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: PCROl-90(01-94.rev.rcl) SET: II PROJECT ADDRESS: 2450 Impala Drive PROJECT NAME: Revision for the Interior Partition for Sesna XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: Please have the other set be slip sheeted to the city's set. By: Bert Domingo Enclosures: Esgil Corporation D GA D MB D EJ D PC 4/27/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 *• (858)560-1468 *• Fax (858) 560-1576 EsGil Corporation 2n Partners/tip with government for 'Buitding Safety DATE: April 24, 2001 Q APPLICANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: PCROl-90(01-94.rev) SET: I PROJECT ADDRESS: 2450 Impala Drive PROJECT NAME: Revision for the Interior Partition for Sensa The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IX| The applicant's copy of the check list has been sent to: TedCaliguri - (-7<*o)6ob-zi2.0 l?«,»)c,o%»-2 2450 Impala Drive, Carlsbad, CA 92009 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Stephen Brown Telephone #: (858) 459-8050 Date contacted:4-2^' (by:i***>) Fax #: ^aun^^- Mail Telephone ^ Fax -~ In Person REMARKS: By: Bert Domingo Enclosures: Esgil Corporation GA MB n EJ PI PC 4/17/01 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 Carlsbad PCR01-90(Ol-94,rev) April 24, 2001 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: PCR01-90(01-94.rev) JURISDICTION: Carlsbad OCCUPANCY: B USE: Office TYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: AprU 24, 2001 ACTUAL AREA: 26100 SQ. FT. STORIES: TWO HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGiL CORPORATION: 4/17/01 PLAN REVIEWER: Bert Domingo FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tJfonv.dot Carlsbad PCR01-90(01-94.rev) April 24, 20O1 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • MISCELLANEOUS 2. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 3. The detail J/A7 is not compatible with the cross referenced designation under legend on sheet A-1 4. Any access/exit door for office 107? 5. Please submit ICBO approval for the polyglass walls. 6. Please submit only the sheets that were changed. Carlsbad PCR01-90(01-94.rev) April 24, 2001 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation. Thank you. Carlsbad PCR01-90(01-94.rev) AprU 24; 2001 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad 94.rev) PLAN CHECK NO.: PCR01-90(01 DATE: April 24, 2001PREPARED BY: Bert Domingo BUILDING ADDRESS: 2450 Impala Drive BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq.Ft) cb Valuation Multiplier By Ordinance 1994 UBC Building Permit Fee v Reg. Mod. VALUE ($) 1994 UBC Building Permit Fee $272.34 Type of Review: D Repetitive Fee Repeats Complete Review Other Hourly 2.5 Structural Only Hours * Esgil Plan Review Fee $217.88 * Based on hourly rate Comments: Sheet 1 of 1 macvalue.doc