Loading...
HomeMy WebLinkAbout2458 OCEAN ST; ; CB931044; PermitB U I L D I N G P E R M I T Permit No: CB931044 Project No: A9301484 Development No: 02/16/94 14:09 1 Page 1 of 1 Job Address: 2458 OCEAN ST Suite: Permit Type: MISCELLANEOUS Parcel No: 203-022-16-00 Lot#: Valuation: 5,950 Construction Type: NEW Occupancy Group: Reference#: Status : ISSUED Applied: 09/28/93 Apr/Issue: 09/28/93 Entered By: MDP Description: 25 SQUARES OF RE ROOFING : WOOD TO TILE Appl/Ownr : REAGAN ROOFING 167 CEDAR ROAD VISTA, CA . 9208 3 *** Fees Required Fees: Adjustments: Total Fees: Fee description Miscellaneous Fee #1 * MISCELLANEOUS TOTAL *** 159.00 .00 159.00 *** 619 758-9140 Fees Collected & Credits *** Total Credits: Total Payments: Balance Due: Units Fee/Unit - .00 134.00 25.00 Ext fee Data 159.00 PC/BP 159.00 AL APPROV~'f 0 /4'/ · DATE~ CE _____ , CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PERMIT APPLICATION PI.AN CHECK NO. City of carlsbad Building Departllef'lt 207S Las PalllBS Dr., carlsbed, CA 92009 (619) 438·1161 I. P£kMII IYPE A -U COmmerc1al LI New Butldmg LI lenant Improvement B -D Industrial U New Building D Tenant Improvement C -)(Residential □ Apartment □ Condo □ Single Family Dwelling □Addition/Alteration □ Duplex U Demolition □ Relocation LI Mobile Home □ Electrical □ Plumbing □Mechanical □Pool □ Spa □Retaining Wall □Solar /(9the~C 2. PROJECT INFORMATION Address 2.4J5(J (!?c..cAAJ 'ST; BuUdmg or Suite No. Nearest Cross Street CHECK BEWW IF SOBMII 1£0: □ 2 Energy Cales □ 2 Structural Cales □ 2 Soils Report □ 1 Addressed Envelope ASSESSOR'S PARCEi. DESCRIPTION OF WORK R. f:..movL SQ. FT. 2 i; -Et-# OF SIDRIES I a::. z... 3. WN IACI PERSON (tr dnferent from applicant) NAME ADDRESS CITY ST A TE ZIP CODE DAY TELEPHONE FOR OFFICE USE ONLY mt o. PROPOSED USE 4. APPLICANI )(WNIRACIOR □AGENI FORWNIRACIUR DOWNER □AGENI FOR OWNER c1TY Vts•A-sTATEC4-•· ="¾~~RR ~R?tJ l-F- ZIP CODE 9'2.tJ8 '5 DAY TELEPHONE 7.r;; B-91 40 CITY 9,4--m E; STATE 6. WNiiW!IOR ADDRESS ZIP CODE DAY TELEPHONE NAME MOJ"l.-ADDRESS ZIP CODE CITY STATE DAY TELEPHONE CITY BUSINESS LlC. # '¼::" -k-, \e,, STATE LlC . .4-,4eql, LlCENSE CLASS C-g 4 CITY STATE ZIP CODE DAY TELEPHONE STATE LlC. # 7. WuRkERS' WMPENSAIION Workers' Compensation Ueciaratmn: I hereby alurm that I have a cert1tlcate of consent to self-msure issued by the Director of lndustnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). SIGNATURE DATE 8. UWNER-BOnnmt oocootAIION Owner-Builder Oeclarat1on: I hereby affirm that I am exempt from the COntracto?s Llcense Law for the foilowmg reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's Llcense Law does not apply co an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving chat he did not build or improve for the purpose of sale.). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's Llcense Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section ________ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such pennit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's Llcense Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or chat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). SIGNATURE DATE COMPLEIE IRIS SECIION FOR NON-RESIDENIIAL B0IWING PERMIIS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □YES □NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? CYES □NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □YES □NO IF ANY OF TIIE ANSWERS ARE YES, A FINAL CERTIFICATE OF CXIlJPANCY MAYNOf BE ISSUED AFTER JULY 1, 1989 IINIJ!SS TIIE APPIJCANT HAS MET OR IS MEIITING TIIE REQlllREMENfS OF TIIE OFFICJ! OF EMERGENCY SERVICES AND TIIE AIR FOillJ1lON CONTROL DISllllCT. 9. WNSlkUCIION LENDING AGENCY I hereby aihrm that there 1s a construction lendmg agency for the performance of the work for which this pemut 1s issued (Sec 309?(1} Civil Code). LENDER'S NAME LENDER'S ADDRESS 10. APPLICANI CPltliPiCAIIUN I certify that I have read the apphcatlon and state that the above mformat1on 1s correct. I agree to comply with all City ordmances and State laws relating co building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I AIID AGREE ID SAVE INDF.MNIFY AND KEEP IIARMUlSS TIIE CTIY OF CARISBAD AGAINST AIL 1JA111U11ES, JUDGMENTS, CX>STS AND EXPENSES WIIlCII MAY IN ANY WAY ACXJUJE AGAINST SAID CTIY IN CONSEQUENCJ! OF nm GRANTING OF 11ns PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at a time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLlCANTS SIGNATURE <jJ_ ~ DATE: 9-2#-'23 4\ V CITY OF CARLSBAD SUPPLEMENTAL BUILDING PERMIT APPLICATION FOR REROOFING 1. JOB ADDRESS 2 4 5 8 2. TYPE OF BUILDING: RESIDENTIAL~ COMMERCIAL __ 3. ROOF SLOPE: RISE 7 inches in 12 inches 4. TYPE OF EXISTING ROOF COVERING iv'Po'I> S'Hnllt>LL s SHEATHING_~~'i:~/~/' ____ _ 5. NUMBER OF EXISTING ROOF COVERINGS (circle one) (!) 2 3 *6. NEW ROOF MATERIAL v, F CLAss_A._ WEIGHT PER SQUARE 950 7. NUMBER OF SQUARES --=2.=5'------- 8. TRADE NAME QJ&CU Ti£ ,1 L-tf MANUFACTURER L._ / i=-6 "Tl L£... 9. ROOF SYSTEM APPROVAL UL No. _____ Other /C.80 -26 Sh 10. IS THE EXISTING STRUCTURAL DESIGN SUFFICIENT TO SUSTAIN THE WEIGHT OF THE PROPOSED ROOF YES X NO --- If the answer is no, a roof plan must be provided with this application. 11. Fire rating of roof: Class A_x_ Class B __ I understand the following inspections are required: 1. Tear Off/Pre-inspection prior to installing new roof covering. 2. Final Inspection I agree to provide a ladder extending at least 2 rungs above the roof for inspection. 2-16-94- DATE Contractor -~X ........... _ Owner ---Contractor Name __ ~__,_,£."'--"{!;,"''A---'--"'-/"----'~--=-'--'c'J"-';:'---1_,<./_G'----- *6 -Rolled Roofing, Tile, Shake, Shingle, ·Asphalt/Comp Fiberglass, Built up. C\ 'U :::~ ~~ C,") ... ) IDQ ... t ,:.t, ..... ''? Iii:'\ UnderwrHers Laboratories Inc.® ~ USTEO PREPARED ROOF COVERING MATERIAL _ ~ ~•• SHAKES ISSUE NO f:371 421 / F/RF:: RETARDANT PRESSURE TREATED CLASs C · • • " SHAKES OR SHINGLES DEGREE OF RESISTANCE OF EXTERNAL r -_ FIRE ANO FlAMMABILITV LIMITS IN I . ~MERICAN WOoo TREATERS, INC. ACCORDANCE WITH UL STANDARD 790 J 00 BOB MITCHE WHEN APPLIED IN ACCORDANCE WITH '' I · 2 LL AVE. INSTRUCTI0/1/S INCLUDED WITH THIS AOoF/N.° . _SUM~,!NASHINGTQN 98295 I I I . I I I I I I I I I I I n 0 r1 < t-i 0 t:1 (J} n ::tl H ~ H 0 ....,. - 1111111~ 5 n 0 23 M ..... -t-j Ul t-j H ..... •·· t--1 ~ f::, H ~ t-j H ~ -~ < M t' Lj •u . r:J 0 . M ::-, c., C: ~} "" t,j > H 0 t-j 0 ~ ~ (/) (/} 1--.,D ~ ()J ~ ;~ >--v '~ (,_; * OQ ~ H ~ . -r-U) ~ ~ .-t ~ ·~ n :;,:. ~ ''\ Lowell A. Dukleth, Consulting Engineers CE -#9901 C1 \ y of C ar·] sb;.d c/o Regan Ro□f1nq 167 Cedar Rd . Vista , Calif . 92083 3521 Buena Creek Rd . Vista, CA 92084 (619) 727-2321 • (619) 727-9676 FAX Jan 3 0 , 1 994 9 3 --.l .t 3 l~e : Use of concrete roof tile to reroof existing residence at 2458 Ocean St . Carlsbad, California. Gentlemen : This is to advise vou that l have personal ]v inspected the subject root structure a n d f1nd it satisfactory tor the support of c oncrete roof tiles laid i.,,Jit.h a 3 " headlap . J have formed this professional opinion aiter gathering data and analyz i ng the followin g information: 1. The structure was built in 1 973 under the Uniform Buil ding Code and City of Carls bad i n spection . Some original construction plans are available. 2. Existing roof suppo r t i.s as fol l ows : Residence : 2x8 @24" 15. 2 11 max . span conventional canst . 2x8 @24" 13'0" max . span cathedral cei l 'g. 3 . The roof pi tr: h is 7 in 1 2 . 4 . A 4x4 co l . support in the 1 ivi.ng room has a questionable top c1m11ection. T l,e engineer is to be notified during con struc t ion in order to have this support improved as required . 5. The foll o wing represenls the Cone ti le w/ 3'' hdlp Lifetile Building paper-·lnsulat.ion-11isc 1 5\32 Plywood 1x4 ski.p boards Roof Joists 2x8 @ 2 11 1• -~1£1" r&G Ce d ar c e .i. l · g new loading conditions . Wt in PSF Cath· l Conv · IC80#2656 9.5 9 .5 t). 2 0 .2 1.4 1.4 1. 1 1. J. 1 . 4 1. 4 1. 4 -0- DEAD LDAD 15 .0 1 3 .6 LlVE LOAD!O t o 200sfl DL+LL TCJTAL 16 .0 3 .1.. 0 16.0 2 9 .6 DESIGN LOADS 3 1 3 0 lt is my ~rofes sional opinion that the roof s t r u cture was d e signed i"or the above DE.SIGN LOADS and is therefore considered sa t isfactory for th~ support of t he imposed loads . to be of serv ice . Please det:';,,Js,:;~~ ~ ~ . Du k 1 et h RCE :tt:990 1