HomeMy WebLinkAbout2459 OCEAN ST; ; CB141623; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-21-2014 Residential Permit Permit No: CB141623 Building Inspection Request Line (760) 602-2725 Job Address: 2459 OCEAN ST CBAD St: C Permit Type: RESDNTL Sub Type: -RAD Parcel No: 2030210203 Lot #: 0 Valuation: $32,591.00 Constuction Type: 513 Occupancy Group: Reference #: # Dwelling Units: 1 Structure Type: Bedrooms: 0 . Bathrooms: 0 Orig PC #: Project Title: DIXON RES REMODEL 2 EXISTING BATHROOMS AND KITCHEN 567 SF Status: ISSUED, Applied: 07/08/2014 Entered By: LSM Plan Approved: 08/21/2014. Issued: 08/21/2014 Inspect Area: Plan Check #: Applicant: SAM DROGO 2744 CARLSBAD BL CARLSBAD CA 92008 760-583-8573 Owner: DIXON CHARLES L P0 BOX 4827 CAVE CREEK AZ 85327 Building Permit $330.43 Meter Size Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $231.30 Meter Fee $0.00 Add'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $3.26 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $59.00 Renewal Fee $0.00 ELECTRICAL TOTAL $43.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $42.45 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee . $0.00 Meter Size . Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (5B1473) Fee $1.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $710.44 Total Fees: $710.44 TOW Payments to Date: $710.44 Balance Due: $0.00 inspector,/,tL FINAL,4AP/PRO),AL Clearance: NOTICE: Please take NfTIC at approval of your project includes the Imp sition o fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exaions? You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protesl the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any LTHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLANNING DENGINEERING DBUILDING DFIRE DHEALTH DHAZMAT!AFCD I 44 Building Permit Application Plan Check No. c!AfL I ( .3 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value I CITY O F Ph: 760-602-2719 Fax: 760-602-8558 CARLSBAD email: buildingcarlsbadca.gov Plan Ck. Deposit _.50 www.carlsbadca.gov Date 7 1 t IswPPP I lApN JOB ADDRESS C.._.— SUITESPACE/ntc.,..... I uLIKuru luri UI WUKR ,nc,uoe aquare I•eer or awe owe RfO8(5) op 1/1 5&7 L TT EXISTING USE I PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) I FIREPLACE I AIR CONDITIONING çp4-FrL_I '4-2 I I & IYES D#. NO YES OE IFIRESPRINKLERS YESENO APPLICANT NAME PROPERTYOWN ER Primary Contact ADDRESS 7144 CALP 00451 4f5 ADDRESS O\OT (_ E ZIP A STATE STATE CITY cA ZIP qzmb PHONE ' b5Th I FAX PHONE /,,ôz 4o ii FAX EMAIL — co-.--_-- EMAIL DESIGN PROFESSIONAL CONTRACTOR BUS NAM ADDRESS ADDRESS Z,1*di: CITY STATE ZIP U1 STATE ZIP PHONE HONE P FAX (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter , commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a D ,sf nnt mnm than flua h,,n,lr,l einlinrc t5SflflU Workers' Compensation Declaration: I hereby affirm under penally of pe4ury one of the following declarations: EJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. C] I have and will maintain workers' compensation, as required by Section 370001 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co.___________________________________________________________ Policy No. Expiration Date section need not be completed if the permit is for one hundred dollars ($100) or less. Thi Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (5100,000), In addition to the cost of compensation, damage; as provided for In Section 3706 of the Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE DATE I hereby affirm that lam exempt from Contractor's License Law for the following reason: [] 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractcr's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. if, however, the building or improvement Is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). C] I, as owner of the properly, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [J I am exempt under Section _____________Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed properly improvement Dyes [:]No I (have! have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address! phone! contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (Include name/address/phone/type of work): PROPERTY OWNER SIGNATURE []AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or futu're building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility lobe constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a truction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name aL. Lender's Address IcerthatIhavereadtheappIlcadonandsathattheaboveinformationisconsctandthatthelnfonnationonthepIansisaccurete. I agree tocamplywith all Cityotthnanoes and State laws elatingto building constiucticn. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 59 deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Oflial under the previsions of this Code shall expire by limitation and became null and void tithe building or work authorized by such permit is not commenced within 180 days from the date of such permit on riding or work such permit is suspended or abandoned at any time after the work is commenced bra period of 180 days (Section )OSAA Uniform Building Code). APPLICANT'S SIGNATU DATE -7 - ZZ J cc STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CE RTIFICATE . P rojects. Fax (760) 602-8560, Email buiIdinaCarlSbadCa.gOV or Mail the completed form to City of Carlsbad, Building Division-1635 Faraday Avenue, Carlsbad, California 92008. CO#: (office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1.) ASSOCIATED CIS# MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) NO CHANGE IN USE / NO CONSTRUCTION MAIL! FAX TO OTHER: __________________________________ CHANGE OF USE / NO CONSTRUCTION ,APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB141623 Type: RESDNTL RAD DIXON RES- REMODEL 2 EXISTING BATHROOMS AND KITCHEN 567 SF pf_ Inspection Item Inspector Act Comments 04/28/2015 89 Final Combo - RI UNIT C 04/28/2015 89 Final Combo PY AP 11/06/2014 17 Interior Lath/Drywall PD AP 10/30/2014 16 Insulation PY PA 10/29/2014 16 Insulation PY AP 10/29/2014 18 Exterior Lath/Drywall PY AP 10/29/2014 27 Shower Pan/Roman Tubs PY AP 10/22/2014 84 Rough Combo PY AP 09/11/2014 11 Ftg/Foundation/Piers PY AP 09/10/2014 11 Ftg/Foundation/Piers PY CA Wednesday, April 29, 2015 Page 1 of 1 EsGil Corporation In (Partners/lip with government for (Building Safety DATE: 8/20/2014 .0 APPLICANT 0 JURIS JURISDICTION: City of Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: B14-1623 SET: II PROJECT ADDRESS: 2459 Oceans St. Unit C PROJECT NAME: Dixon Residence Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. LI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. LI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person REMARKS: Please- new TS-1 and A2.2 sheets and slip revised A2.1 sheet to the city I set. (at building department) _--~ J By: David Yao Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC 8/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In lFartrimfiip wit/i government for (Building Safety DATE: 7/18/2014 0 F'LICANT 'iURIS. JURISDICTION: City of Carlsbad / 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.:B14-1623 SET: I PROJECT ADDRESS: 2459 Oceans St. Unit C PROJECT NAME: Dixon Residence Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Sam Drogo Lii EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Sam Drogo Date contacted: - .74 (by: Cj) ljnaii)( Telephone V Fax In Person LII REMARKS: By: David Yao EsGil Corporation LIGA EEJ [I MB E] PC Telephone #: 760-583-8573 Email: samdrogo©hotmail.com Enclosures: 7/10 Fax #: 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad B14-1623 7/18/2014 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: B14-1623 JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2459 Oceans St. Unit C FLOOR AREA: Remodel 2-bath and kitchen REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 7/18/2014 STORIES: 1 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/10 PLAN REVIEWER: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 lRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 20.12 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad B14-1623 7/18/2014 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 2. The scope of work shall be clearly identified on the plan. (new windows, Any mechanical and electrical changes?). Section R106.2. 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2013 California Residential Code, which adopts the 2012 IRC, 2012 UMC, 2012 UPC and the 2011 NEC. Section R106.1. 4. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 5. Show locations of permanently wired smoke alarms with battery backup, per Section R314: Inside each bedroom. Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each story, including basements. NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 6. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the City of Carlsbad B14-1623 7/18/2014 smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.3.1. 7. Specify on the plans that any existing smoke alarms that are more than 10 years old will be replaced. Section R314.3.2. 8. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each story, including basements. NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 9. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. 10. Bathrooms and powder rooms must be mechanically ventilated (an openable window won't suffice). Section R303.3.1 and CIVIC 403.7. 11. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: Glazing in doors. (door 8) Glazing adjacent to a door where the nearest vertical edge of the glazing is within a 24" arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60" above the walking surface. (window 7) Glazing in individual fixed or operable panels that meet all of the following conditions: City of Carlsbad B14-1623 7/18/2014 Exposed area of an individual pane is greater than 9 square feet, and: Exposed bottom edge is less than 18" above the floor, and: Exposed top edge is greater than 36" above the floor, and: One or more walking surfaces are within 36" horizontally of the plane of the glazing. 12. Guards (Section R312): (any changes?) Shall be installed along open-sided walking surfaces that are located more than 30" above the floor or grade below. Shall have a height of 4" (may be 34" along the sides of stairs). Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". Shall be detailed to show capability to resist a concentrated load of 200 pounds in any direction along the top rail. Table R301.5. 13. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. 14. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. 15. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.8(A): Family, living, bedrooms, dining, halls, etc. C) GFCI protected outlets for locations described in NEC 210.8: Kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. 16. Show on the plans that countertop receptacle outlets comply with CEC Article 210.52(C): In kitchens a receptacle outlet shall be installed at each counter space 12 inches or wider; Receptacles shall be installed so that no point along the wall line is more than 24 inches; Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle. (Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces). 17. Per CEC Article 210.11(C)3, note on the plans that bathroom circuiting shall be either: •A 20 ampere circuit dedicated to each bathroom, or At least one 20 ampere circuit supplying only bathroom receptacle outlets. City of Carlsbad B14-1623 7/1812014 Show on the plans a wall receptacle within 36" of each lavatory in the bathroom. CEC 210.52(D). Dimension on the plans the 30" clear width required for the water closet compartment and the 24" clearance required in front of the water closet. CPC 402.5. Provide a note on the plans: The control valves in showers, bathtubs, and bidets must be pressure balanced or thermostatic mixing valves. CPC Sections 408, 409, 410. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.5 GPM, and showerheads may not exceed 2.0 GPM of flow. CPC Section 403 and 408. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. . RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the .Green Building Standards Code which became effective January 1, 2011 and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, along with additions/alterations that increase the building's conditioned area, volume or size. CGC Section 303.1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. Indoor water use. Show compliance with the following table for new/replaced fixtures, perCGC 4.303.1. FIXTURE FLOW RATES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1.28 gallons/flush Showerheads 2 gpm @ 80 psi Lavatory faucets 1.5 gpm @ 60 psi' Kitchen faucets 1.8 gpm @ 60 psi City of Carlsbad B14-1623 7/18/2014 I. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management, per CGC 4.408.2. Operation and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC 4.410.1. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4504.3 and Tables 4.504.1, 4.504.2, 4504.3 and 4504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified in Section 4.505.3. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC 4.505.3. Indoor air quality. Note on the plans that. bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. City of Carlsbad B14-1623 7/18/2014 . ENERGY CONSERVATION 32. For plans submitted for plan check on or after 711114, provide a Prescriptive or Performance energy design, demonstrating compliance with current 2013 energy efficiency standards. Information and Forms are available at: www.energy.ca.gov/title24/201 3standards o Current Performance energy design versions are: CBECC-Res ver. 2 (Public Domain software) hftp://www.bwilcox.com/BEES/BEES.html EnergyPro V6.1 & V6.2 (6.1 is not valid after 07131114) www.enerqysoft.com Right-Energy Title 24 v1.0 www.wriqhtsoft.com Prior to the initial plan submittal, the energy design was required to be registered with the appropriate HERS provider data registry. Before the next plan review, please register the energy design and resubmit plans with completed forms showing the registration number. CaICERTS is the only current registry: https:llwww.calcerts.com Include on the Title Sheet of the plans the following statement: "Compliance with the documentation requirements of the 2013 Energy Efficiency Standards is necessary for this project. Registered, signed, and dated copies of the appropriate CFi R, MR, and CF3R forms shall be made available at necessary intervals for Building Inspector review. Final completed forms will be available for the building owner." Include all applicable sections of the MF-i R form with the plans. Residential energy lighting requirements: ES 150.0(k) In the kitchen, at least one-half of the wattage rating of the fixtures must be high efficacy. In bathrooms, at least one fixture shall be high efficacy and all remaining fixtures shall be high efficacy or be controlled by a vacancy sensor. High efficacy fixtures are required for all other rooms (not described above) or low efficacy fixtures are allowed if controlled by a dimmer or a vacancy sensor. Outdoor lighting fixtures that are attached to a building are required to be high efficacy or be controlled by a combination photo-control/ motion sensor. 37. Residential ventilation requirements: Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior.. Detail compliance by including a complying exhaust fan or a ducted range hood to the exterior. City of Carlsbad B14-1623 7/18/2014 Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or some similar source of moisture" Residential bathroom exhaust fans shall be energy star rated and shall be control by a humidistat capable of an adjustment between 50 and 80% humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not required if the bathroom exhaust fan is also the dwelling whole house ventilation. Mechanical whole house ventilation must be provided. Identify the fan providing the whole house ventilation (complete with CFM) on the floorplans. For additions 1,000 square feet or less, whole house ventilation is not required. For additions over 1,000 square feet, the whole house ventilation CFM shall be based upon the entire (existing and addition) square footage, not just the addition. All fans installed to meet all bf the preceding requirements must be specified at a noise rating of a maximum I "Sone" (for the continuous use calculation) or 3 "Sone" (for the intermittent use calculation). Mandatory Mechanical design requirements: ES 150.0 Mechanical system sizing from ASHRAE, SMACNA, or ACCA. See ES 150.0(h) for information. Duct System Sealing and Leakage Testing ES 150.0(m) Indoor Air Quality Ventilation: Field Verification and Diagnostic Testing. Specify on the plans the make, model, type and efficiency of the space heating (or cooling) system. .• MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes E3 No L3 42. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any City of Carlsbad B14-1623 7/18/2014 questions regarding these plan review items, please contact David Yao at EsGil Corporation. Thank you. City of Carlsbad B14-1623 7/18/2014 [DO NOT PAY— THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: B14-1623 PREPARED BY: David Yao DATE: 7/18/2014 BUILDING ADDRESS: 2459 Oceans St. Unit C BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) remodel per city 32,591 Air Conditioning Fire Sprinklers TOTAL VALUE 32,591 Jurisdiction Code Icb IBY Ordinance I Bldg. Permit Fee by Ordinance I $330.43 I Plan Check Fee by Ordinance I $214.781 Type of Review: ED Complete Review E1 Structural Only El Other El Repetitive Fee Repeats Hourly IHr. @ * EsGil Fee I I $185.041 Comments: total Esgil fee=1 85.04+43(calgreen)=228.04 Sheet I of I macvalue.doc + CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 7/25/14 PROJECT NAME: Dixon residential remodel PROJECT ID: PLAN CHECK NO: CB141623 SET#:l ADDRESS: 2459 Ocean St APN: 203-021-02-01 VALUATION: $32,591 APPLICANT CONTACT: samdrogo@hotmaii.com FX-1 Tlis plan check review transmittal is to notify you of clearance by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by the Construction & Inspection Division is required: Yes No X GM For status from a' division not marked below, please call 760-602-2719 F-1 This plan check review is NOMPLETE Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Thj?1J? LAND DEVELOPMENT ENG. f 111JiJIi1J 760-602-2750 Chris Sexton Kathleen Lawrence Greg Ryan 760-602-4624 - 760-602-2741 "- 760-602-4663 Chris.Sexton@carlsbadca.gov I Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov fl Gina Ruiz Linda Ontiveros. Cindy Wong 760-602-4675 760 602-2773 -- 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.wong@carlsbadca.gov Dale Willis 760-602-2784 fl Dominic Fieri 760-602-4664 Dale.Willis@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: City use only Dedication existing per document no.: 78-264624 F 40N,> CITY OF CAR LSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P.29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.20v DATE: 7-8-14 PROJECT NAME: PROJECT ID: PLAN CHECK NO: CB 14-1623 SET#: I ADDRESS: 2459 Ocean St APN: 203-021-02-03 This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required J Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. 'This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: samdrogo@hotmail.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton Kathleen Lawrence Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chris.Sexton@carlsbadca.gov KathIeen.Lawrence@carIsbadCa.Ov Gregorv.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carIsbadca.gov Linda.Ontiveros@carlsbadca.gov Cvnthia.Won@carIsbadca.ov Dominic Fieri 760-602-4664 Dominic.Fieri@carIsbadca.gov Remarks: