HomeMy WebLinkAbout2463 IMPALA DR; ; CB151531; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-17-2015 Commercial/Industrial Permit Permit No: CB151531
Building Inspection Request Line (760) 602-2725
Job Address: 2463 IMPALA DR CBAD
Permit Type: TI Sub Type: INDUST Status: ISSUED
Parcel No: 2090411500 Lot #: 0 Applied: 05/20/2015
Valuation: $5,300.00 Construction Type: NEW Entered By: JMA
Occupancy Group: Reference # Plan Approved: 06/17/2015
Issued: 06/17/2015
Inspect Area
Project Title: ULTURA WATER: INSTALL PALLET Plan Check #:
RACKS
Applicant: Owner:
WAREHOUSE SOLUTIONS INC R I F III -IMPALA L L C
P.O. BOX 60727 11620 WILSHIRE BLVD #300
SAN DIEGO CA 92166 LOS ANGELES CA 90025
619-873-4410
Building Permit
$78.91
Meter Size
Add'I Building Permit Fee
$0.00
Add'I Red. Water Con. Fee
$0.00
Plan Check
$55.24
Meter Fee
$0.00
Add'I Building Permit Fee
$0.00
SDCWA Fee
$0.00
Plan Check Discount
$0.00
CFD Payoff Fee
$0.00
Strong Motion Fee
$1.48
PFF (3105540)
$0.00
Park Fee
$0.00
PFF (4305540)
$0.00
LFM Fee
$0.00
License Tax (3104193)
$0.00
Bridge Fee
$0.00
License Tax (4304193)
$0.00
BTD #2 Fee
$0.00
Traffic Impact Fee (3105541)
$0.00
BTD #3 Fee
$0.00
Traffic Impact Fee (4305541)
$0.00
Renewal Fee
$0.00
PLUMBING TOTAL
$0.00
Add'I Renewal Fee
$0.00
ELECTRICAL TOTAL
$0.00
Other Building Fee
$0.00
MECHANICAL TOTAL
$0.00
Pot. Water Con. Fee
$0.00
Master Drainage Fee
$0.00
Meter Size
Sewer Fee
$0.00
Add'I Pot. Water Con. Fee
$0.00
Redev Parking Fee
$0.00
Red. Water Con. Fee
$0.00
Additional Fees
$0.00
Green Bldg Stands (SB1473) Fee
$1.00
HMP Fee
9?
Fire Expedidted Plan Review
$0.00
Green Bldg Standards Plan Chk
??
TOTAL PERMIT FEES
$136.63
Total Fees: $136.63 TotO
if
Payments To Date:
$136.63 Balance Due:
$0.00
FINAL A PR VALE
L
Inspector:44Z�-Date: 1!5 Clearance:
NOTICE: Please take NgrICE t at approval of your, project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." ou have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: I IPLANNING DENGINEERING (_,.,jBUILDING :.;FIRE HEALTH HAZMAT!APCD
" Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Plan Check No. � ( S - 1s3�
Est. Value
Ph:760-602-2719 Fax:760-602-8558
Cad= email: building@carlsbadca.gov
Plan Ck. Deposit
Date S /f
www.carisbadca.gov
JOB ADDRESS
2463 Impala Drive
SUI7EN/SPACE#/UNITN
APN
661 - 312 - 139 - 4
CONSTR. TYPE OCC. GROUP
CT/PROJECT # LOT # PHASE: # # OF UNITS It BEDROOMS # BATHROOMS TENANT BUSINESS NAME/���/.��1*
_.
_
DESCRIPTION OF WORK: Include Square Feet of Affected Areas) --
Installation of Pallet Storage Racking
EXISTING USE
PROPOSED USE
GARAGE (SF)
PATIOS (SF)
DECKS (SF)
FIREPLACE
AIR CONDITIONING
YES❑p NO[::]
YES F-1NO ❑
IFIRESPRINKLERS
YES[:] NO[:]
APPLICANT NAME
Primary Contact Warehouse Solutions Inc.
PROPERTYOWNER NAME RIF III, Impala LLC
ADDRESS
ADDRESS
12562 Highway 67
11620 Wilshire Blvd, Ste.1000
CITY STATE ZIP
Lakeside CA 92040
CITY STATE ZIP
Los Angeles CA 90025
PHONE
FAX
PHONE
FAX
619-873-4410
619-449-1710
EMAIL
EMAIL
anitathornton(aD.warehouslesolutions.com
DESIGN PROFESSIONAL
CONTRACTOR BUS. NAME
Warehouse Solutions Inc.
ADDRESS
ADDRESS
12562 Highway 67
CITY STATE ZIP
CITY STATE ZIP
Lakeside CA 92040
PHONE
FAX
PHONE
FAX
619-873-4410
619-449.1710
EMAIL
EMAIL
anitathorntonOwarehousesolutions.com
STATE LIC. #
STATE UC.#
CLASS
CITY BUS. LIC.#
918115
I
C611D24
1 1226177
koG r uoi. oumunss ., iu nuiessiuns wue: miry ucy or Lounty wmcn requires a permit to construct, alter, Improve, demolish or repair anyy structure, prior to its issuance, also requires the
applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the
Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars ($500)).
Workers' Compensation Declaration: I hereby affirm under penafty of perjury one of the following declarations:
❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
❑✓ 1 have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. State Compensation Insurance Fund Policy No. 9092900.2014 Expiration Date
Th'section need not be completed If the permit is for one hundred dollars ($100) or less. 3 t t/�
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compens lion L s o
California. WARNING: Failure to sec4re workers' compensation rage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, m as roved r' o S n 3706 of the Labor code, interest and attomey's fees.
.eS CONTRACTOR SIGNATURE \ \ v AGENT DATE S /ZO/I S
1 hereby affirm that 1 am exempt from Contractor's License Law for Me following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one: year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or impmves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
1 am exempt under Section Business and Professions Code for this reason:
1. 1 personally plan to provide the major labor and materials for construction of the proposed property improvement. ❑Yes ❑No
2. 1(have / have not) signed an application for a building permit for the proposed work.
3. 1 have contracted with the following person (firm) to provide the proposed construction (indtde name address / phone I contractors' license number):
4. 1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone I contractors' license number):
5. 1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
)KPROPERTY OWNER SIGNATURE ❑AGENT DATE
Is the applicant or future building occupant required to submit a business pfan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley -Tanner Hazardous Substance Account Act? Yes No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name N/A Lender's Address
I certifythatl have read theapplication and stateMtheabove infamlation is correctandthatthe information onthe plans isaccurate. I agreemcomplyMth all City ordinances and State laws relatingm building construction
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Bui ng Official under the provisions of IN Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within
180 days from the date of such permit or if thlbuuVing or work authorized by such id is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Cade).
At�APPLICANVS SIGNATURE
DATE s , .'
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email buildinQ0carlsbadcalaw or Mail the completed form to City of Cadsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
r0#: (Office Use Only)
CONTACT NAME
OCCUPANT NAME
ADDRESS
BUILDING ADDRESS
CITY STATE
ZIP
CITY STATE ZIP
Carlsbad CA
PHONE
FAX
EMAIL
OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
PICK UP: CONTACT (Listed above)
OCCUPANT (Listed above)
CONTRACTOR (On Pg.1)
ASSOCIATED CB#
MAIL T0: CONTACT (Listed above)
OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
NO CHANGE IN USE / NO CONSTRUCTION
MAIL / FAX TO OTHER: _
CHANGE OF USE / NO CONSTRUCTION
A5APPLICANT'S SIGNATURE
DATE
Inspection List
Permit#: CE151531
Date Inspection Item
08/04/2015 89 Final Combo
07/31/2015 89 Final Combo
07/28/2015 89 Final Combo
Type: TI INDUST ULTURA WATER: INSTALL PALLET
RACKS
Inspector Act Comments
PY AP
PY NR
PY CA
Thursday, November 19, 2015 Page 1 of 1
CITY OF
CARLSBAD INSPECTION RECORD
Building Division
0 INSPECTION RECORD CARD WITH APPROVED
PLANS MUST BE KEPT ON THE JOB
2 CALL BEFORE 300 pm FOR NEXT WORK DAY INSPECTION
Z FOR BUILDING INSPECTION CALL: 760-602-2725
OR GO TO: www.Carlsbadca.goy/Building AND CLICK ON
"Request Inspect!5!rr"
DATE: b," , 11, ( &
CR151531 2463 IMPALA DR
ULTURA WATER: INSTALL PALLET
RACKS
TI INDUST
Loft WAREHOUSE SOLUTIONS INC
Y
IF "YES" IS CHECKED BELOW THAT DIVISION'S APPROVAL IS REQUIRED PRIOR TO
IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE
ALL REQUIRED APPROVALS ARE SIGNED OFF— FAX TO 760.602-8560, EMAIL
BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE., CARLSBAD, CA 92008.
AT 760-602-2700 BETWEEN 7:30 AM — 8:00 AM THE DAY OF YOUR INSPECTION.
Required Prior to Requesting Building Final If Checked YES
®_Planning/Landscape
REQUESTING
PHONE NUMBERS
TO BLDGINSPECTIONS@CARLSBADCA.GOV
BUILDING
A FINAL BUILDING INSPECTION.
PROVIDED BELOW. AFTER
OR
INSPECTORS CAN BE REACHED
760-944-8463
Allow 48 hours
Fire Prevention
760-602-4660
Allow 48 hours
type or inspection
Tvae of Inspection
BUILDINGDate
#it FOUNDATION
Inspector
Date
#31 ❑ ELECTRIC UNDERGROUND ❑ UFER
Inspector
#12 REINFORCED STEEL
#34 ROUGH ELECTRIC
#66 MASONRY PRE GROUT
#33 ❑ ELECTRIC SERVICE ❑ TEMPORARY
❑ GROUT ❑ WALLDRAINS
#35 PHOTOVOLTAIC
#10 TILT PANELS
#39 FINAL
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#41 UNDERGROUND DUCTS & PIPING
#14 SUBFRAME ❑ FLOOR ❑ CEILING
#44 ❑ DUCT& PLENUM ❑ REF. PIPING
#15 ROOFSHEATHING
#43 HEAT -AIR COND. SYSTEMS
#13 EXT. SHEAR PANELS
#49 FINAL
#16 INSULATION
. _ . •
#18 EXTERIOR LATH
#81 UNDERGROUND (11,12,21,31)
#17 INTERIOR LATH & DRYWALL
#82 DRYWALL,EXT LATH, GAS TES (17,18,23)
#51 POOL EXCA/STEEL/BOND/ FENCE
#83 ROOF SHEATING, EXT SHEAR (13,15)
#55 PR EPLASTER/ FINAL
#84 FRAME ROUGH COMBO (14,24,34,44)
#19 FINAL
#85 T-Bar (14,24,34,44)
CODE0 PLUMBING
#22 ❑ SEWER & BL/CO ❑ PL/CO
Date
Inspector
#89 FINAL OCCUPANCY (19,29,39,49)
FIRE
Date
Inspector
#21 UNDERGROUND ❑WASTE ❑ WTR
#24 TOP OUT ❑ WASTE ❑ WTR
A/S UNDERGROUND VISUAL
#27 TUB & SHOWER PAN
A/S UNDERGROUND HYDRO
#23 ❑ GAS TEST ❑ GAS PIPING
A/S UNDERGROUND FLUSH
#25 WATER HEATER
A/S OVERHEAD VISUAL
/
#28 SOLAR WATER
A/S OVERHEAD HYDROSTATIC
#29 FINAL
A/S FINAL
CoDE# STORM WATER
F/A ROUGH -IN
#600 PRE -CONSTRUCTION MEETING
F/A FINAL
#603 FOLLOW UP INSPECTION
FIXED EXTINGUISHING SYSTEM ROUGH -IN
#605 NOTICE TO CLEAN
FIXED EXTING SYSTEM HYDROSTATIC TEST
#607 WRITTEN WARNING
FIXED EXTINGUISHING SYSTEM FINAL
#609 NOTICE OFVIOLATION
MEDICAL GAS PRESSURETEST
#610 VERBAL WARNING
MEDICAL GAS FINAL
REV 10/2012
SEE BACK FOR SPECIAL NOTES
0 __000*,
P.O. Box 2450
Alpine, CA 91903
Phone 619-540-0612
Fax 619-445-5889
Inspection & Material Testing
1��
DATE
COVERING WORK PERFORMED REQUIRING
APPROVAL BY THE SPECIAL INSPECTOR OF: ❑ Reinforced Concrete ❑ Reinforced Masonry ❑ Struct. Steel Assembly
(One inspection per Report) ❑ Pre -Stressed Concrete ❑ Fireproofing Other:-S
Project Name:
/
Project No:
Perm' Application No:
Plan File No:
Project 5treetAddress \� ��
L J
Jurisdiction
/�L5
role an pec cats s d e & Date evilslon
Architect
Engineer
General Contractor
L ",- .1�;•r , r_
Contractor Doing Reported Work
- ..�• �j
CODE
DESCRIPTIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES
INFORMATION ABOUT - AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED: NUMBER, TYPE, & IDENTIFICATION NUMBERS OF TEST SAMPLES
4-' / - S f c1 C
IGJy`-� e:,. _ Q�
.r •-7:_i-
077 2 . 1
TIME ON
SITE
TIME OFF
SITE
REG.
HOURS
O.T.
HOURS
# OF TEST
SPECIMENS
NaRLLLLeggiistered Inspector (Print)
JOB SITE CONTACT IS ASKED TO SIGN TO VERI N CTION HO S ONLY. THE
CONTENT OF THIS REPORT AND FEE CHARG AR THE RESPONSI ILITY OF HERS.
Signature:
O er ; Authorize Job Site C tact
Signature of Registered Inspector
Date of Report Registered Number
CERTIFICATE OF COMPLIANCE
TO THE BEST OF MY KNOWLEDGE, THE ABOVE REPORTED WORK, UNLESS
OTHERWISE NOTED, IS IN CONFORMANCE WITH THE APPROVED PLANS AND
SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE
GOVERNING STANDARDS.
EsGil Corporation
In Partnership with Government for Building Safety
DATE: 5/29/2015
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 15-1531 SET: I
PROJECT ADDRESS: 2463 Impala Dr.
PROJECT NAME: Storage Racks for Ultura Water
❑ APPLICANT
❑ JURIS.
❑ PLAN REVIEWER
❑ FILE
❑ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
® The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
❑ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
❑ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Email:
Mail Telephone Fax In Person
❑ REMARKS: 1. Fire Department ap Tea'&required. 2. City to field verify that the path of travel
from the handicapped parking space to the rack area and the bathrooms serving the rack area
comply with all the current disabled access requirements.
By: David Yao Enclosures:
EsGil Corporation
❑ GA ❑ EJ ❑ NIB ❑ PC 5/21
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
City of Carlsbad 15-1531
5/29/2015
[DO NOT PAY— THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-1531
PREPARED BY: David Yao DATE: 5/29/2015
BUILDING ADDRESS: 24-63 Impala Dr.
BUILDING OCCUPANCY:
BUILDING
PORTION
AREA
( Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
racks
per city
5,300
Air Conditioning
Fire Sprinklers
TOTAL VALUE
j
5,300
Jurisdiction Code Icb IBy Ordinance
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance W
Type of Review: 7, 1 Complete Review
❑ Repetitive Fee
i Repeats
❑ Structural Only
❑ Other
Hourly Hr. @ "
E❑sGil Fee
$79.11
$51.42
Comments:
Sheet 1 of 1
macvalue.doc +
Al
' CITY OF
CARLSBAD
PLAN CHECK
REVIEW
TRANSMITTAL
DATE:05/20/2015 PROJECT NAME: RACK WORK
PLAN CHECK NO: 1 .SET#: 1 ADDRESS: 2463 IMPALA DRIVE
VALUATION: $5,300
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
PROJECT ID: CB151531
APN: 661-312-139-04
This plan check review is complete and has been APPROVED by the ENGINEERING
Division.
By: VALRAY NELSON
A Final Inspection by the ENGINEERING Division is required Yes , No
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: ANITATHORNTON@WAREHOUSESOLUTIONS.COM
ron-! orie olp nnore gig` r, ivisiof) a li af.'d ,4',,elow prova/
'nl the e qqn£,p �e i,e ,.Li1rei,JP %1✓ to fh"i xu Ccle p�"�p' j� gpg f • '¢[gyp g 'y p.�
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
ENGINEERING
FIRE PREVENTION
760-602-4610
760-602-2750
760-602-4665
Chris Sexton
Kathleen Lawrence
Greg Ryan
760-602-4624
760-602-2741
760-602-4663
Chris.5exton@carlsbadca.goy
Kathleen.Lawrence@carlsbadca. ov
Gret;or�Ryan@carlsbadca.gov
Gina Ruiz
Linda Ontiveros
Cindy Wong
760-602-4675
760-602-2773
760-602-4662
Gina. Ruiz@carlsbadca.eov
Linda.0ntiveros@carlsbadca eov
Cynthia.Won @carlsbadca.yov
1/0 ValRay Marshall
760-602-2773
Dominic Fieri
760-602-4664
tialRay.Marshal6carlsbadca.gov
dca. Dominic.Fieri@carlsbaov
—�—
Remarks:
BUILDING PLADevelopment Services
NCHECK Land Development Engineering
C I F
CHECKLIST 1635 Faraday Avenue
J Y 0
CARLSBAD QUICK-CHECK/APPROVAL 760-602-2750
www.carlsbadca.gov
ENGINEERING Plan Check for C13151531
Project Address: 2463 IMPALA DRIVE
Project Description: STORAGE RACK INSTALLATION
ENGINEERING Contact: VALRAY NELSON
Phone: 760-602-2741
RESIDENTIAL INTERIOR
RESIDENTIAL ADDITION MINOR
(<$20,000.00)
CARLSBAD PREMIER OUTLETS
OTHER: GYM
Valuation: $5,300
Email: VALRAY, MARSHALL CcOCARLSBADCA, GOV
Fax: 760-602-1052
V TENANTIMPROVEMENT
PLAZA CAMINO REAL
COMPLETE OFFICE BUILDING
r , , — , , — * , — , , — , , — * , — , * — * , OFFICIAL USE ONLY - - — - - — - - — - - — - - — - - — - - I
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT
BY: VALRAY NELSON DATE:05/2012015
REMARKS: STORAGE RACK INSTALLATION, NO FEES INSTALLED.
Notification of Engineering APPROVAL has been sent to ANITATHC)RNTON@WAREHO(JSESOLUTIONS.COM
via VALRAYBAIRSHALL@CARLSBADCA.GOV on 05/20/2015
E-36 Page 1 of 1 REV 4/3 0/11
r
Fee Calculation Worksheet
ENGINEERING DIVISION
Prepared by: Date: 05120/2015 GEO DATA: LFMZ: I B&T:
Address: 2463 IMPALA DRIVE Bldg. Permit #: CB1 1531
Fees Update by: Date: 05/2012015 Fees Update by: Date: 05I201201
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use:
Sq.Ft./Units
EDU's:
Types of Use:
Sq.Ft./Units
EDU's:
Types of Use:
Sq.Ft./Units
EDU's:
Types of Use:
Sq.Ft./Units
EDU's:
ADT CALCULATIONS: List types and
square footages for all uses.
Types of Use:
Sq.Ft,/Units
ADT's:
Types of Use:
Sq.Ft./Units
ADT's:
Types of Use:
Sq.Ft./Units
ADT's:
Types of Use:
Sq.Ft./Units
ADT's:
FEES REQUIRED:
Within CFD: YES (no bridge & thoroughfare
fee in District #1, reduces
Traffic Impact Fee)
1. PARK -IN -LIEU FEE: NW QUADRANT / NE QUADRANT
SE QUADARANT
ADT'S/UNITS:
X FEE/ADT:
=$
23RAFFIC IMPACT FEE:
ADT'S/UNITS:
I X FEE/ADT:
=$
3. BRIDGE & THOROUGHFARE FEE:
DIST. #1
DIST.#2
ADT'S/UNITS:
FEE/ADT:
=$
4. FACILITIES MANAGEMENT FEE
ZONE:
ADT'S/UNITS:
X FEE/SQ.FT./UNIT:
I
=�
5. SEWER FEE
EDU's
BENEFIT AREA:
EDU's
6. DRAINAGE FEES:
ACRES:
7, POTABLE WATER FEES:
UNITS I CODE
X FEE/EDU: I =$
X FEE/EDU: I =$
PLDA: HIGH MEDIUM
X FEE/AC: I =$
NO
SW QUADRANT
1-1
DIST.#3
LOW
CONN. FEE I METER FEE I SDCWA FEE
TOTAL
INS
PLANNING DIVISION Development Services
X BUILDING PLAN CHECK Planning Division
�p REVIEW CHECKLIST 1635 Faraday Avenue
CAR LS /► D P-28 (760) 602 4610
[�f-"� www.carlsbadca.eov
DATE: 5-21-15 PROJECT NAME: PROJECT ID:
PLAN CHECK NO: CB 1.5-1531 SET#: 1 ADDRESS: 2463 Impala Dr APN:
Z This plan check review is complete and has been APPROVED by the Planning
Division.
By: Chris Sexton
A Final Inspection by the Planning Division is required ❑ Yes E] No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
[] This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to:
anitathornton@warehousingsolutions.com
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
l.VV-QVL"FQ1V
!VV-VVL'LI UV ...
'•-:-�VVZ7�/G�TVVJ _ - ._;-.
Chris Sexton
Chris Glassen
I i
Greg Phan
760-602-4624
+'60-602-2784
760-602-4663
Chris.Sexton@carlsbadca.gov
c v
Grc gcart',€ vaar zcarlsba ca,.gov
Gina Ruiz
ValRay Marshall
L
Cindy Wong
760-602-4675
760-602-2741
760-602-4662
Gina.Ruiz@carlsbadca.gov
Vr�IRay jar ,ha11r carlsbad a, ov
Q i th _ldrar g` rlsb ca. ov
�- Linda Ontiveros
�_j
Dominic Fieri
760-602-2 7 73
a 60-602-4664
l_s��ci .ear c t t,r, )E:I k do i. go,
t�cjmiilli .Fie,4 i 7�c arisbadca. o_v
Remarks: pallet storage racking
PLAN CHECK
REVIEW
TRANSMITT .
DATE: 6-4-15 PROJECT NAME: Ultura Water
PLAN CHECK NO: CB151531
PROJECT ID:
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
SET#: 1 ADDRESS: 2463 Impala Dr. APN:
Z This plan check review is complete and has been APPROVED by the Fire Division.
By: D. Fier!
A Final Inspection by the Fire Division is required ❑ Yes ® No
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to:
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
[� Chris Sexton
760-602-4624
Chris.Sexton@carisbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
Remarks:
Kathleen Lawrence
760-602-2741
Kathleen.Lawrence@carlsbadca.gov
[] Linda Ontiveros
760-602-2773
Li nda.Ontiveros@ca rlsbadca.:sov
Greg Ryan
760-602-4663
Gregory.Ryan@carisbadca.gov
Cindy Wong
760-602-4662
Cynthia.Wong@carisbadca.gov
Dominic Fieri
760-602-4664
Dominic.Fieri@car[sbadca.gov
Carlsbad Fire Department
Plan Review Requirements Category: TI , INDUST
Date of Report: 06-04-2015
Name:
Address:
Permit #: CB151531
WAREHOUSE SOLUTIONS INC
P.O. BOX 60727
SAN DIEGO CA
92166
Job Name: ULTURA WATER: INSTALL PALLET
Job Address: 2463 IMPALA DR CBAD
Reviewed by:
INCOMPLETE I he_item you have submi d'for review is inco ete: At this timi_; this of
---adequately conduct a°Keview to determine compliance with the applica codes`ard/or star dards
carefully all comments a ached. Please resubmit tlie� necessary plans and r specific�fii s, fivith
to this office for review n approval. . ,
.j
Conditions:
Cond: CON0008320
[MET]
` APPROVED: .
face ca . t
1 Pl~ease r view
charier "c uded",
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF
BUILDING PERMIT.
THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON,
CONDITIONS IN
CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW.
Entry: 06/04/2015 By: df Action: AP
Structural
Concepts
E
RECEIVED
MAY 2 0 701
:I (Y OF CARLSBAL
UILDING DIVISION
Engineering
1615 Yeager Ave
La Verne, CA. 91750
Tel:909.596.1351 Fax:909.596.7186
e-mail: mail@sceinc.net
Project Name : ULTURA
Project Number : 0-112014-4LV
Date : 11 /24/ 14
Street Address : 2463 IMPALA DR
City/State : CARLSBAD CA 92010
Scope of Work : SELECTIVE RACK
DEC 0 2 2014
C�
('Fi1S• I �,31
tructurai
Concepts
ngineering
1200 N. Jefferson Este Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763
By: S.P. Project: ULTURA WATER Project #: 0-112014-4
TABLE OF CONTENTS
TitlePage........................................................... ....... .......... ........ .............
......... .... 1
Tableof Contents.....................................................................................................
2
Design Data and Definition of Components .................................................
I.......... 3
CriticalConfiguration..............................................................................................
4
SeismicLoads..........................................................................................................
5 to 6
Column... .............. ....... ............. ............................... ................ ...........
.......... ......... 7
Beamand Connector...............................................................................................
8 to 9
Bracing....................................................................................................................
10
Anchors..................................................................................................................
11
BasePlate .....................__. ............. ................................................._...............
12
Slabon Grade ..... .............................. ............................. ........ ..............
................. . 13
OtherConfigurations ................ ........................................... _................................
14
Ji T! PA. �,VA.TER TYPE 1 aB 2 TRAMS of 1 /24/24
vft
tructural
Concepts
=-
,�� � Engineering
By: S.P. Project: ULTURA WATER Project #: 0-112014-1
Design Data
1) The analyses herein conforms to the requirements of the:
2012I3C Section 2209
2013 CBC Section 2209A
ANSI MH 16.1-2012 Speciflcatwns for the Design oflndustrial Steel Storage Racks 2012 RMI Rack Design Manual'
ASCE 7-10, section 15.5.3
2) Transverse braced frame steel conforms to ASfM A570, Gr.50, with minimum strength, Fy=50 ksi
Longitudinal frame beam and connector steel conforms to AST1 A570, Gr.50, with minimum yield, Fy=50 ksi
All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi
3) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein.
4) All welds shall conform to AWS procedures, utilizing E70xx electrodes or similar. All such welds shall be performed
in shop, with no field welding allowed other than those supervised by a licensed deputy inspector.
5) The existing slab on grade is 5" thick with minimum 2500 psi compressive strength. Allowable Soil bearing capacity is 1000 psf.
The design of the existing slab is by others.
6) Load combinations for rack components correspond to 2012 RMI Section 2.1 for ASD level load criteria
Definition of Components
Fri
He
Front View: Down Aisle
(Longitudinal) Frame
Column
3eam to Column
-onnector
Base Plate and
Anchors
T
Panel
Height
i� Frame �}
(� Depth
Section A: Cross Aisle
(Transverse ) Frame
Horizontal
Brace
Diagonal
Brace
-�jiRA \AIATF-R-T-1 1 FB 2 FRAME Page '�� of � � � 112412014
Str?O"al
V oncepts
- Engineering
- — 1200 N. Jefferson Ste, Ste F Anaheim, CA 928€17 Tel: 714.632.7330 Fax: 714.632.7763
By: S.P. Project: ULTURA WATER Project #: 0-112014.4
Configuration & Summary: TYPE 1 PUSH BACK 2 DEEP 2 FRAME
102" — +
?— 42" ='t +-- 42" Wit`
**R4CK COLUMN REACTIONS
ASD LOADS
AXIAL DL= 100lb
AXIAL LL= 4,0001b
5,E 5MICAXIAL Ps=f/- 1,8541b
BASE MOMENT= 0 in -lb
Seismic Criteria
# Bm Lvls
Frame Depth
Frame Height
# Diagonals
Beam Length
Frame Type
Ss=1.053, Fa=1.079
2
42 in
120.0 in 1
3 1
102 in
Single Row
Component
Description
STRESS
Column
Fy=50 ksi
Struc C3x3.5
P=2050 lb, M=13574 in -lb
0.47-OK
Column & Backer
None
None
None
N/A
Beam
Fy=50 ksi
Struc C4x4.5
Unbraced Length=72"
Capacity: 5017 Ib/pr
0.8-OK
Beam Connector
Fy=50 ksi
Lvl 1: 2 bolt OK Mconn=9175 in -lb
Mcap=27480 in -lb
0.33-OK
Brace -Horizontal
Fy=36 ksi
Struc Ll-1/2 x Ll-1/2 x 1/8
0.31-OK
Brace -Diagonal
Fy=36 ksi
Struc 1-1-1/2 x LI-1/2 x 1/8
0.88-OK
Base Plate
Fy=36 ksi
5x4xl/4 Fixity= 0 in -lb
0.71-OK
Anchor
1 per Base
0.5" x 3.25" Embed HILTI SCREW ANCHOR HUS EZ ESR 3027 Inspection Reqd (Net Seismic Uplift=482 Ib)
0.708-OK
Slab & Soil
5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure
0.45-OK
Level
Load**
Per Level
Beam Spcg
Brace
Story Force
I Transv
Story Force
Longit.
Column
Axial
Column
Moment
Conn.
Moment
Beam
Connector
1 4,000 lb 14.0 in 44.0 in 139 Ib 106 Ib 4,100 lb 4,010 "# 9,175 "# 2 bolt OK
2 4,000 lb 78.10 in 44.0 in y141D oyo io z,uw iU /,//i * c LJUIL
24.0 in
** Load defined as product weight per pair of beams Total: 1,053 lb 802 lb
Notes I PB UNIT 2 WIDE x 2 FRAME` x 2000# PALLET
UJUKA V/A?ER TYFc i P 2 FRAVff Page _ of f J 1 l i2-11
tructurai
®nCeptS
Engineering
-
-- 1200 N. Jefferson Ste Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763
By: S.P. Project: ULTURA WATER
Project #: 0-1120144
Seismic Forces Configuration: TYPE 1 PUSH BACK 2 DEEP 2 FRAME
Lateral analysis is performed with regard to the requirements of the 2012 RMI ANSI MH 16.1-2012 Sec 2.6 & ASCE 7-10 sec 15.5.3
Ss= 1.053
Transverse (Cross Aisle) Seismic Load
S1= 0.408
v= Cs*Ip*Ws=Cs*Ip*(0.67*P*Prf+D)
vt
Fa= 1.079
Csl= Sds/R
Fv= 1.592
= 0.1894 Cs -max * Ip= 0.1894ti
Sds=2/3*Ss*Fa= 0.758
Cs2= 0.044*Sds V", ,,= 0.015
Shc=2/3*Si*Fv= 0.433
= 0.0333 Eff Base Shear=Cs= 0.1894 Transverse Elevation
Ca=0.4*2/3*Ss*Fa= 0.3030
Cs3= 0.5*S1/R \rJs= (0.67*PLRFi * PL)+DL (RMI 2.6.2)
(Transverse, Braced Frame Dir.) R= 4.0
= 0.0510 = 5,560 Ib
Ip= 1.0
Cs -max= 0.1894
Vtransv=Vt= 0.1894 * (200 Ib + 5360 Ib)
PRFI= 1.0
Base ShearCoeff=Cs= 0.1894
Etransverse= 1,053 Ib
Pallet Height=hp= 48.0 in
Lett& States Level Transverse seismic shear per upright
DL per Beam Lvl = 100 lb
Level PRODUCT LOAD P P*O.E57*PRFi DL hi vii*hi
F Fi*(hi+hp/2)
1 4,000 Ib 2,680 Ib 100 Ib 14 in 38,920
139.1 Ib 5,286-#
2 4,000 Ib 2,680 Ib 100 Ib 92 in 255,760
913.9 lb 106,012-#
sum: P=8000lb 5,360lb 200 lb W=5560lb 294,680
1,053lb 2=111,298
Similarly for longitudinal seismic bads, using R=6.0 Ws= (0.67 * PLR * P) + DL PRF2= 1.0 =`+ Z'• =\h I
Csl=Shc/(T*R)= 0.1443
- 5,560 Ib
(Longitudinal, Unbraced Dir.) R=
6.0
Cs2= 0.0333
Cs=Cs-max*Ip= 0.1443
T=
0.50 sec
Cs3= 0.0340
vlong= 0.1443 *
(200 Ib + 53601b)
Cs -max= 0.1443
Elongitudinai= 802 Ib
LuuitStates Level LorWt se&nksheaperupright
Level PRODUC LOAD P
P*O.157*PRF2 DL
hi wi*hi
Ft Front View
1 4,000 Ib
2,680 Ib 100 Ib
14 in 38,920
105.9 Ib
2 4,000 Ib
2,680 lb 100 lb
92 in 255,760
696.1 Ib
sum: 5,360lb 200 lb W=5560lb 294,680 802lb
ULTURA OVATEP-IYFE 1 FB 2 FRAME Page ') of 1/1_ ' 112412C i
tructural
Concepts
- Engineering
- 1200 N. Jefferson Ste. Ste F Anaheim CA 92807 Tel: 714.532 7330 Fax; 714.632.7763
By: S.P. Project- ULTURA WATER Project #: 0-112014.4
Downaisle Seismic Loads Configuration: TYPE 1 PUSH BACK 2 DEEP 2 FRAME
Determine the story moments by applying portal analysis. The base plate is assumed to provide no fixity.
Seismic Story Forces
Typical frame made
Vlong= 802 lb
Tributaryarea of two columns
Vcol=Vlong/2= 401 lb
fra
of rack me�, — ---- --
`
F1= 106 lb
ti
p{ r
• , k�
E
ti `:
Typical Frame made
F2= 696 lb
of two columns
®/
,
{
Top View
Se„ ---------
Front View Side View
Seismic Story Moments
Conceptual System
Mbase-max= 0 in -lb <__= Default capacity hl-eff= hl - beam clip height/2
Mbase-v= (Vcol*hleff)/2 = 10 in Vcol
= 2,005 in -lb <__= Moment going to base
Mbase-eff= Minimum of Mbase-max and Mbase-v
= 0 in -lb PINNED BAISEASSUMED
M 1-1= [Vcol * hleff]-Mbase-eff M 2-2= [Vcol-(Fl)/2] * h2
= (401 lb * 10 in)-0 in -lb = [401 lb - 348.1 Ibj*78 in/2
= 4,010 in -lb = 13,574 in -lb
Mseis= (Mupper+Mlower)/2
Beam to Column Elevation
Mseis(1-1)= (4010 in -lb + 13574 in-lb)/2 Mseis(2-2)= (13574 in -lb + 0 in-lb)/2
= 8,792 in -lb = 6,787 in -lb rho= 1.0000
Summary of Forces
LEVEL hi Axial Load Column Moment** Mseismic** Mend -fixity Mconn** Beam Connector
1 14 in 4,100 lb 4,010 in -lb 8,792 in -lb 4,315 in -lb 9,175 in -lb 2 bolt OK
2 78 in 2,050 lb 13,574 in -lb 6,787 in -lb 4,315 in -lb 7,771 in -lb 2 bolt OK
Mconn= (Mseismic + Mend-fixity)*0.70*rho
Mconn-allow(2 Bolt)= 27,480 in -lb
**all moments based on limit states level loading
ULTURA WAFER -TYPE 1 PB 2 fKAME Page � of " i2412-- 1 4
tructurai
oncepts
- n ineerin
g 9
1200 N. Jefferson Sirs Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763
By: S.P. Project: ULTURA WATER Project #: 0-112014-4
Column (Longitudinal) Configuration: TYPE 1 PUSH BACK 2 DEEP 2 FRAME
Section Properties
Column Member= Struc C3x3.5
3.00 in
Aeff = 0.881 inA2
Fy= 50,000 psi
L
Ix = 1.414 in,,4
Kx= 1.7
1.38 in
Sx = 0.943 inA3
Lx= 76.0 in
s
rx = 1.267 in
Ky= 1.0
'�
Iy = 0.138 inA4
Ly= 44.0 in
Sy = 0.157 inA3
Cm= 0.85
ry = 0.396 in
Loads Considering loads at level 2
COLUMN DL= 50 lb Critical load cases are. RMT Sec Z 1
COLUMN PL= 2,000 lb Load Case 5.- : (1+0.105*5ds)D + 0.75*(1.4+0.145d5)*5*P + 0.75*(0.7*rho*E)<= 1.0, ASD Method
Mcol= 13,573 in -lb
Sds= 0.7575 Load Case 6.- (1 +0.104*5ds)D + (0.85+0.1456s)*B*P + (0.7*rho*E)<= 1.0, ASD Method
1+0.105*Sds= 1.0795
1.4+0.14Sds= 1.5061 By analysis, Load case 6 governs utilizing loads as such
1+0.14Sds= 1.1061
0.85+0.14*Sds= 0.9561 Axial Load=Pa= 1.10605*50 lb + 0.95605*0.7*2000 lb
B= 0.7000 = 1,394 lb
rho= 1.0000 Moment=Mx= 0.75*0.7*rho*Mcol
= 0.7 * 13573 in -lb
= 9,501 in -lb
Axial Analysis
(kl/r)x = (1.7*76 in/1.267 in) (kl/r)y = (1*44 in/0.396 in)
= 101.97 = 111.11
(kl/r)max= 111.11
SINCE (KL/r)max > Cc, USE EQTN E2-2
Fa = 12nA2E/23N/r)A2
23(kl/r)A2
= 12,096 psi
fa= Pa/AREA
= 1,582 psi
Bendina Analysis
Cc = (2nA2E/Fy)A0.5
= 107.0
fa/Fa= 0.13 < 0.15
fbx= Mx/Sx Fbx= 0.6*Fy
= 10,075 psi = 30,000 psi
F'ex= (12*nA2*E)/(23*(KL fb/Fb= 0.34
= 14,361 psi
(1-fa/F'e)=
Combined Stresses
(HI-3)-
fa/Fa + fb/Fb= 0.47 <_ 1.0 OK
LTi.JRA , ATE-k PE 1 r D 2FRA` Page of i f ; I ! 12-V
tructural
Concepts
-- ngineering
1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763
By: S.P. Project: ULTURA WATER Project #: 0-1120144
Beam Configuration: TYPE 1 PUSH BACK 2 DEEP 2 FRAME
The beam to column connection is assumed to provide partial end fixity for the beam frame. The end moment calculated herein is added
to the lateral force force portal moment when analyzing the connection capacity.
The impact load on the beam is addressed by including the Impact Factor "a" in the determination of the beam center bending stress.
Section Properties
Beam Member= Struc C4x4.5
Beam at Level= 1
Beam Type= Structural
Ix= 3.469 in^4
Sx= 1.735 in^3
Beam Length=L= 102.0 in
Unbraced Length, Lu= 72.0 in
ti
Beam Weight= 4.0 Ib/ft
Thickness= 0.137 in 4.000
in
Beam Shape= Channel
d/Af= 9.4 `
Impact Factor (a)=[1-(25%/2)]= 0.875
Loads
Load Case. D + 0.88P + Impact RMI Section 2.1, Load case 10
Bending
--------------
% End Fixity= 25 %
Coeff 8= 0.104/0.125
0 = 0.25
= 0.832
Mcenter= 13*(wL^2/8)
Mcenter= Mcenter(simple ends) - O*Mcenter(fixed ends)
= 0.832*(wL^2/8)
= wL^2/8 - (0.25 * wL^2/12)
Mends= O*Mmax(fixed ends)
= wL^2/8 - wL^2/48
= (wLA2/12)*0.25
= 0.104 * wL^2
= 0.0208*wL^2
Fy= 50,000 psi
Fb= 0.6 * Fy
= 30,000 psi
Fb' = 12,000/(lu*d/Af)
= 12,000/(72*9.4)
Fb-eff= 17,730 psi
= 17,730 psi
Live Load/Pair= 4,000 lb
Dead Load/Pair= (4 Ib/ft) * 2 * 102 in/12 Dist Load=w= 19.9 lb/in
= 68 lb
Mcenter= 0.104 * wL^2
Mends= 0.0208*wL^2
= 21,577 in -lb
= 4,315 in -lb
M= 21,577 in -lb
fb= (M/Sx)/a -4
= 14,213 psi
fb/Fb= 14213 psi/17730 psi
0.80
Bending Capcity= 5,017 lb/pair
includes impact factor (a) reduction coefi; conservatvely 1.OP is used in lieu of 0.88P
<= 1.0, OK
<=== Critical
Deflection
Defl-allow=L/ 180 Defi= B * [5wL^4/(384*E*Ix)]
= 0.567 in = [5*19.9 Ib/in*(102 in)^4/(384*29.5x10^6 psi * 3.469 in^4)]*0.832
= 0.228 in <= 0.567 in, OK
Deflection Capacity= 10,048 lb/Pair
Allowable load per beam pair= 5,017 lb
__T, j2A, ; a E - �= ! or, 2 F= ,ME Page q of i � 1 I12412014
�t��-e-O�ts
turol
ngineering
1200 N. Jefferson Ste, Ste IFAnaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763
By: S.P. Project: ULTURA WATER Project #: 0-1 i2014-4
2 Bolt Beam to Column Connection Conficguration: TYPE I PUSH BACK 2 DEEP 2 FRAME
1"
Mconn max= (Mseismic + Mend-fixity)M0.70*Rho
= 9,175 in -lb
Connector Type= 2 Bolt
Shear Capacity of Bolt
Bolt Uiam= 0.50 in Fy= 50,000 psi
Pv-bolt= 2 1 ,000 psi
Ashear= (0.5 m) — 2 * Pi/4
= 0. 1 963 in — 2
Pshear= Ashear * Pv
= 21,000 psi * 0. 196.3 m - 2
= 4,122 lb
Bearmq Capacity of Bolt
tcol= 0. 137 in Fu= 65,000 psi
Bolt Dom= 0.5
Pbearin9= 1.2 * Bearing Area * Fu
= 1.2 ` 0.5 in dram * U. 1 37 in ' 65000 psi
= 5,343 lb > 41 22 lb
Moment Capacity of Bracket
Edge Distance=E= 1 .00 in Bolt Spacing= 4.0 in
C= P I +P2 tclip= 0. 15 in
I.I I 'PI
Mcap= 5clip * Fbendrncg C*d= Mcap
=0.14in-3*0.66*Fy
= 4.620 in -lb
= 4620 in-lb/(I . I I m) Thus, P I = 4,1 22 lb
= 4. 162 lb
Mconn-allow= [P I *6"+P 1 *(2"/6")*0.51
= 41 22 LB*[6"+(2"/6")*2"]
= 27,480 in -lb > Mconn max, OK
P1
8„ 6"
P2
C
Standard Bolt Pattern
Fy= 50,000 psi
5chp= O. 140 in — 3
d= E
1 .00 in
ULTURA WATER. -TYPE I PB 2 FRAME Page 0 of 1124120 14
StConcepts
tural
ngineering
_ 7: 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763
By. S.P. Project: ULTURA WATER Proiect #: 0-112014-4
Transverse Brace TYPE 1 PUSH BACK 2 DEEP 2 FRAME
Diagonal Member= struc a-11/2 x u-1/2 x 1/8
Area= 0.35 in^2
r min= 0.285 in
K= 1.0
Fy= 36,000 psi
Frame Dimensions
Horizontal Member= Struc Li-1/2 x Ll-1/2 x 1/8
Area= 0.35 in^2
r min= 0.285 in
K= 1.0
# 0
Load Case 6:: (1+ > + ((0.85+0.14.Sds)*S*P +[0.7*rho*E]<= 1.0, ASt7 Method
Bottom Panel Height=H= 48.0 in Clear Depth= D-8*2-4" =d = 35.3 in
Frame Depth=D= 42.0 in Ldiag= [d^2 + H^2]^0.5
Column Width=B= 1.4 in = 59.6 in
Diagonal Brace
Vtransverse= 1,053lb
Vb=Vtransv*0.7*rho= 1053 lb * 0.7 * 1
= 737Ib
(kl/r)max= 209.12
(kl/r)x = (1*59.6 in/0.285 in)
= 209.12
(KL/r)max > Cc, Eqtn E2-2 Applies
Fa = 12n^2E/23(kl/r)^2
23(kl/r)^2
= 3,415 psi
fa/Fa= 0.88 <_ 1.0 OK
Horizontal Brace
V=Vtransv= 737Ib
Vdiag= V*(Ldiag/D)
= 1,046lb
Tvpiral Panel
Configuration
Cc = (2n^2E/Fy)^0.5 fa= P/AREA
= 126.1 = 2,989 psi
Check Weld
Weld Tension= 1,046 lb
tweid= 0.125 in
Lweld= 4.0 in
Fweld= 70,000 psi
Weld Capacity= tweld*0.7071*Lweld*0.3*Fweld*1.0
= 7,425lb 14.1% OK
(kl/r)x = (1*42 in/0.285 in) (kl/r)max= 147.37
= 147.37 Cc = (2n^2E/Fy)^0.5
= 126.1
(KL/r)max > Cc, Eqtn E2-2 Applies
Fa = 12n^2E/23(kl/r)A2 fa= P/AREA
23(ki/r)^2 = 2,106 psi
= 6,876 psi Diag Status= 10.88
fa/Fa= 0.31 <= 1.0 OK Horiz Status= 10.31
tructurai
Concepts
—Wl Engineering
By: S.P. Project: ULTURA WATER Project #: 0-112014-4
Single Row Frame Overturning Configuration: TYPE 1 PUSH BACK 2 DEEP 2 FRAME
Critical Load case(s):
1) RMI Sec 2.1, item 9: (0.6-0.14Sds)D + (0.6-0.14Sds)*B*Papp - 0.7*E*rho
Sds= 0.7575
Vtrans=V=E=Qe= 1,053lb (0.6-0.14Sds)= 0.4940
DEAD LOAD PER UPRIGHT=D= 200 lb (0.9-0.2Sds)= 0.7485
PRODUCT LOAD PER UPRIGHT=P= 8,000 lb B= 1.0000
Papp=P*0.67= 5,360 lb rho= 1.0000
_C1=Wst1=(0.49395*D + 0.49395*Papp*l)= 2,746 lb
Frame Depth=Df= 42.0 in
Product Load Top Level, Ptop= 4,000 lb Htop-Ivl=H= 92.0 in
DL/Lvl= 100 lb # Levels= 2
Seismic Ovt based on E, E(R*hi)= 111,298 in -lb # Anchors/Base= 1
hPinht/rh-nth ratin= ?-2 in hn= 4A n in
hp
I'f Df t
SIDE FLFVATICSN
A Fully Loaded Rack h=H+h
2= 116.0 in
Load case 1:
Movt= E(F*hi)*0.7*E*rho Mst= Wstl * Df/2
T= (Movt-Mst)/Df
= 77,909 in -lb = 2746 lb * 42 in/2
= (77909 in -lb - 57666 in-lb)/42 in
= 57,666 in -lb
= 482 lb Net Uplift per Column
Net Seismic U lift= 482 lb
B Top Level Loaded Only
Load case 1:
0 Vl=Vtop= Cs * Ip * Ptop >= 350 lb for H/D >6.0
Movt= [Vl*h + V2 * H/2]*0.7*rho
= 0.1894 * 4000 Ib
= 62,737 in -lb
= 758Ib
T= (Movt-Mst)/Df
Vleff= 758 lb Critical Level= 2
= (62737 in -lb - 43566 in-lb)/42 in
V2=VpL= Cs*Ip*D Cs*Ip= 0.1894
= 456 lb Net Uplift per Column
= 38 lb
Mst= (0.49395*D + 0.49395*Ptop*1) * 42 in/2
= 43,566 in -lb
Net Seismic U lift= 456 lb
Hncnor
Check (1) 0.5" x 3.25" Embed HILTI SCREW ANCHOR HUS EZ anchor(s) per base plate.
Special inspection is required per ESR 3027.
Pullout Capacity=Trap= 950 lb L.A. City Jurisdiction? NO Tcap*Phi= 950 lb
Shear Capacity=Vcap= 1,550 lb Phi= 1 Vcap*Phi= 1,550 lb
Fully Loaded: (482 lb/950 lb)-1 + (526 Ib/1550 lb)-i = 0.85 <= 1.2 OK
Top Level Loaded: (456 lb/950 lb) -I + (378 Ib/1550 lb)-1 = 0.72 <= 1.2 OK
ULTI KA, IXArER-TY E 1 PE 2 FRAME 1,, -
Page � of .� �i24i2,-
.4
i
tructura!
Concepts
Engineering
1200 N. Jefferson 'ate Ste F Anaheim CA 92807 Tel: 714.632.7330 Fax: 714.632.7763
By: S.P. Project: ULTURA WATER Project #: 0-112014-4
Base Plate Configuration: TYPE 1 PUSH BACK 2 DEEP 2 FRAME
Section a P
Baseplate= 5x4x1/4
Eff Width=W = 5.00 in a = 1.50 in
Mb
Eff Depth=D = 4.00 in Anchor c.c. =2*a=d = 3.00 in
Column Width=b = 3.00 in N=# Anchor/Base= 1
Column Depth=dc = 1.38 in Fy = 36,000 psi
L = 1.31 in
Plate Thickness=t = 0.250 in
{ b
W
Downaisle Elevation
wn Aisle Loads Load Case 5:: (1+0.i'05*5ds)D + 0.75*1-(1.4+0.14W*B*P + 0.75*%07*rh0*E7<= 1 0 A5D Method
COLUMN DL= 100 lb
Axial=P= 1.0795375 * 100 lb + 0.75 * (1.50605 * 0.7 * 4000 lb)
COLUMN PL= 4,000 lb
= 3,271 lb
Base Moment= 0 in -lb
Mb= Base Moment*0.75*0.7*rho
1+0.105*Sds= 1.0795
= 0 in -lb * 0.75*0.7*rho
1.4+0.14Sds= 1.5061
= 0 in -lb
B= 0.7000
Axial Load P = 3,271 lb Mbase=Mb = 0 in -lb
Axial stress=fa = P/A = P/(D*W)
M1= wLA2/2= fa*LA2/2
= 164 psi
= 141 in -lb
Moment Stress=fb = M/S = 6*Mb/[(D*BA2]
Moment Stress=fb2 = 2 * fb * L/W
= 0.0 psi
= 0.0 psi
Moment Stress=f it = fb-fb2
M2= fbl*LA2)/2
= 0.0 psi
= 0 in -lb
M3 = (1/2)*fb2*L*(2/3)*L =:
(1/3)*fb2*LA2 Mtotal = M1+M2+M3
= 0 in -lb
= 141 in-lb/in
S-plate = (1)(tA2)/6
Fb = 0.75*Fy
= 0.01 inA3/in
= 27,000 psi
fb/Fb = Mtotal/[(S-plate)(Fb)]
F'p= 0.7*F'c
= 0.50 OK = 1,750 psi OK
Tanchor =(Mb-(PLapp*0.75*0.46)(a))/[(d)*N/2]
Tallow= 950 1b OK
_ -2,746 lb No Tension
Cross Aisle Loads CL� bad�eRMISc ZZ �m 4: ("I+0,Z 5dsJUL (1 M,145O5%PLfi.75+EL 0,75 <=LD, ASD pf y d
Pstatic= 3,271 lb
Movt*0.75*0.7*rho= 58,431 in -lb Pseismic= Movt/Frame Depth
Frame Depth= 42.0 in = 1,391 Ib
P=Pstatic+Pseismic= 4,662lb
b =Column Depth= 138 in
L =Base Plate Depth -Col Depth= 1.31 in
fa = P/A = P/(D*W)
= 233 psi
Sbase/in = (1)(tA2)/6
= 0.01 inA3/in
fb/Fb = M/[(S-plate)(Fb)]
= 0.71 OK
M= wLA2/2= fa*LA2/2
= 201 in-lb/in
Fbase = 0.75*Fy
= 27,000 psi
_Check uplift load on Baseplate
Check uplift forces on baseplate with 2 or more anchors per RMI 7.2.2.
the base plate configuration consists of two anchor bolts located on either side
f the column and a net uplift force exists, the minimum base plate thickness
all be determined based on a design bending moment in the plate equal
to the uplift force on one anchor times 1/2 the distance from
he centerline of the anchor to the nearest edge of the rack column"
T
�f- c ►
Ta a
Ta
Elevation
Uplift per Column= 482 Ib
Qty Anchor per BP= 1
Net Tension per anchor=Ta= 482 lb
c= 1.31 in
Mu=Moment on Baseplate due to uplift= Ta*c/2
= 316 in -lb
Splate= 0,042 inA3
75=
JLTURA b0JAI FR-TY E 1 FB 2 FPA%AE Pacjc I Q of � (3, i 112-1/2 ',
Structural
Concepts
ngineering
1200 N. Jefferson Ste. Ste F Anaheim, CA 92807 Tel` 714 632 7330 Fax 714 632 7763
By: S.P. Project: ULTURA WATER Project ##: 0-112014-4
Slab on Grade Configuration: TYPE 1 PUSH BACK 2 DEEP 2 FRAME
0
y-- x ►� 1-4- c __� j
f y -�
L -�
SLAB ELEVATION
Base Plate
Effec. Baseplate width=B= 5.00 in
Effec. Baseplate Depth=D= 4.00 in
DEAD LOAD=D= 100 lb per column
unfactored ASO load
PRODUCT LOAD=P= 4,000 lb per column
unfactored ASD load
Papp= 2,680 lb per column
P-seismic=E= (Movt/Frame depth)
= 2,092 lb per column
unfactored limit State load
B= 17000
rho= 1.0000
Sds= 0.7575
1.2 + 0.2*Sds= 1.3515
0. 9 - 0.20Sds= 0.7485
Apunct= [(c+t)+(e+t
= 166.88 inA2
�1.t
width=a= 3.00 in
depth=b= 1.38 in
.-_. '...'-`.'...'F4 slab
, . . . . . . . . .
.
-----------
Concrete
' .
.'.'
• • -
a
b e
fc= 2,500 psi
tslab=t= 5.0 in
Cross
tell= 5.0 in
----� ----'
Aisle
phi=0= 0.6
Soil
fsoil=
e
1,000 psf
Down Aisle
.
Movt= 87,882 in -lb
F
Frame depth= 42.0 in
Basepiaie ?!an View
Sds= 0.758
0.2*Sds= 0.152
midway list face of column to edge
of plate=c=
4.00 In
midway cost face of column to edge
of plate=e=
2.69 In
Load Case 1) (1.2+0.2Sds)D + (1.2+0.2Sds)*B*P+ rho*E RMI SEC 2.2 EQTN 5
= 1.3515*100lb+1.3515*0.7*4000lb+1*2092lb
= 6,011 lb
Load Case 2) (0.9-0.2Sds)D + (0.9-0.2Sds)*B*Papp + rho*E RMI SEC 2.2 EQTN 7
= 0.7485 * 100 lb + 0.7485 * 0.7 * 2680 lb + 1 * 2092 lb
= 3,571 lb
Load Case 3) 1.2*D + 1.4*P RMI SEC 2.2 EQTN 1,2
= 1.2*100 lb + 1.4*4000 lb
= 5,720 lb
Effective Column Load=Pu= 6,011 lb per column
Fpunct=
= 79.8 psi
fv/Fv= Pu/(Apunct*Fpunct)
0.451 < 1 OK
Slab Bending
Pse=DL+PL+E= 6,011 lb
Asoil= (Pse*144)/(fsoii)
= 866 inA2
x= (L-y)/2
= 8.1 in
Fb= 5*(phi)*(fc)A0.5
= 150. psi
L= (Asoil)A0.5
= 29.43 in
M= w*xA2/2
_ (fsoil*xA2)/(144*2)
= 226.4 in -lb
y= (c*e)A0.5 + 2*t
= 13.3 in
S-slab= 1*teffA2/6
= 4.17 inA3
fb/Fb= M/(S-slab*Fb)
= 0.362 < 1, OK
ULTL'P,A N/ATEi2-TI,PE ! F5 2 FRAME
Str turat
Ioncepts
— Engineering
By: S.P. Project: ULTURA WATER Project #: 0-112014-
Configuration & Summary: TYPE 2 PUSH BACK 2 DEEP 2 FRAME
it
96
42' --� +— 42" rl
"RACK COLUMN REACTIONS
ASD LOADS
AXIAL DL= 100lb
AXIAL LL= 4,000lb
SEISMICAXIAL Ps=+/- 1,8541b
BASE MOMENT= 0 in -lb
Seismic Criteria
# Bm Lvls
Frame Depthl
Frame Height
# Diagonals
Beam Length
Frame Type
Ss=1.053, Fa=1.079
2
42 in
120.0 in
3
96 in
Single Row
Component
Description
STRESS
Column
Fy=50 ksi
Struc C3x3.5
P=2050 lb, M=13574 in -lb
0.47-OK
Column & Backer
None
None
None
N/A
Beam
Fy=50 ksi Struc C4x4.5 Unbraced Length=72" Capacity: 5355 Ib/pr
0.75-OK
Beam Connector
Fy=50 ksi Lvl 1: 2 bolt OK F Mconn=8994 sn-Ib Mcap=27480 in -lb
0.33-OK
Brace -Horizontal
Fy=36 ksi Struc Ll-1/2 x 1-1-1/2 x 1/8
0.31-OK
Brace -Diagonal
Fy=36 ksi Struc LI-1/2 x Ll-1/2 x 1/8
0.88-0K
Base Plate
Fy=36 ksi 5x4xl/4 Fixity= 0 in -lb
0.71-OK
Anchor
1 per Base 0.5" x 3.25" Embed HILTI SCREW ANCHOR HUS EZ ESR 3027 Inspection Reqd (Net Seismic Uplift=482 Ib)
0.708-OK
Slab & Soil
5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure
0.45-OK
Level
Load**
Story Force
Story Force
Column
Column
Conn.
Beam
Per Level
Beam Spcg
Brace
Transv
Long
Axial
Moment
Moment
Connector
1 4,000 lb 14.0 in 44.0 in 139 lb 106 lb 4,100 lb 4,010 "# 8,994 "# 2 bolt OK
7 d Ann Ih 74 n :.,
Z,u5u io Is,574 "# 7,591 "# 2 bolt OK
24.0 in
** Load defined as product weight per pair of beams Total: 1,053 lb 802 lb
Notes I PB UNIT 2 WIDE x 2 FRAME x 2000# PALLET
JL-JRA NATEF-TYPE 2 PB 2 FRAM= Page Ln of 1121t201 4
1