HomeMy WebLinkAbout2470 FARADAY AVE | 6200 EL CAMINO REAL; ; CB072138; Permit' City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-16-2007 Commercial/Industrial Permit Permit No: CB072138
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
· Valuation:
Occupancy Group:
Project Title:
Applicant:
2470 FARADAY AV CBAD
Tl
2090402800
Sub Type: INDUST
Lot#: 0
$60,830.00 Construction Type: NEW
Reference #:
BECKMAN COULTER
RELOCATE AUTO CLAVE & WASH DOWN ROOM
Owner:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
ISSUED
08/16/2007
MOP
08/16/2007
08/16/2007
GOOD & ROBERTS INC. HAGAMAN FAMILY SURVIVORS 1990 TRUST 11-07-90
1090 JOSHUA WAY
VISTA, CA 92083
619-598-7614
Building Permit
Add'I Building Permit Fee
Plan Check
Add'! Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
STD #2 Fee
STD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$396.41
($1.27)
$257.67
$0.00
$0.00
$12.77
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
5320 EL CAMINO REAL
CARLSBAD CA 92008
Meter Size
Add'! Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
HMP Fee
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$48.00
$35.00
$21.50
$0.00
$0.00
$0.00
$0.00
??
$770.08
Total Fees: $770.08 Total Payments To Date: $770.08 Balance Due: $0.00
FINAL ~APPROVA~
Date· /.J-.---/O r I) K' , I Clearance: ------
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions·hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired.
City of Carlsbad
1635 Faraday Ave., Carlsbad, CA 92008
760;602-27171/ 2718 / 2719
· Fax: 760-602-8558
Building Permit Application
JOB ADDRESS
CT/PROJECT#
-~-EXISTING USE
1-AB
ADDRESS
Est. Value
Plan Ck. Deposit
Date
SUITE#/SPACE#/UNIT#
# BEOROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. lYPE OCC. GROUP
GARAGE (SF) PATIOS (SF)
APPLICANT NAME
ADDRESS ,:: I ,, A"'-A v?~ ~ l "J--Z.. "U:J ~ ~ ·,tN.0 ~~
CITY STATE ZIP SCA-ZIP CJZ4
PHONE FAX FAX
EMAIL
STATECA-
FAX
ARCH/DESIGNER NAME & ADDRESS
c;~L.-~i dl STATE LIC.#
3 S"is1 CLASSB
/Sec. 7031.5 Business and Professions Code: Any City or County which requires a ermit licensed J!Ulluant to the provisions of the Contractor's License Law {Chapler 9, c Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty
construe~ alte~ improve, demolish or reP,air any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is with Section , 00 of Division 3 of the Business and Pro1essions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of mo(e than five hundred dollari {$500}). .
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
D I have and will maintain a certificate of consent to self-Insure for workers' compensati~n as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. . . )21, I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
numberare:lnsuranceCo. S?A?ee<r1P_;jiJJ, 6wa . PolicyNo. JJ3-oooo ;>'15[: Expiration Date /<)/;/20<>?
This section need not be completed if the permit is for one hundred dollars ($100) or less.
D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
25 CONTRACTOR SIGNATURE ,/~ ;_
I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason:
a I, as owner of the properly or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
a I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s} licensed pursuant to the Contractor's License Law}.
a I am exempt under Section ____ B,usiness and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. a Yes a No
2. I {have I have not} signed an application for a building permit for the proposed work.
3. I have contracted with the following person {firm) to provide the proposed construction (include name address I phone I contractors' license number}:
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supeivise and provide the major work {include name I address I phone I contractors' license number}:
5. I will provide some of the work, but I have contracted (hired} the following persons lo provide the work indicated (include name I address I phone I type of work):
25 PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required lo submi~iness plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? ~es a No _
Is the applicant or future building occupant required lo obtain a permit from the air pollution control district o~a· qu lity management district? a Yes a No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? a Yes N6
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUE L SS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
, 'J,~,
I certify that I have read the application and state that the above information is correct and that the information on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above m tioned property for inspection pul]loses. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES Y WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official u !h.,.r-;n,~-.. is Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within
180 days from the date of such permit or if the buildin ch permit is suspended or abandoned at any time after the work is commenced for a period of 180 days {Section 106.4.4 Uniform Building Code).
25 APPLICANT'S SIGNATURE DATE B 1s; CJ
City of Carlsbad Bldg Inspection Request
For: 12/10/2008
Permit# CB072138 Inspector Assignment: JM
Title: BECKMAN COULTER
Description: RELOCATE AUTO CLAVE & WASH DOWN ROOM
Type:TI
Job Address:
Suite:
Location:
Sub Type: IN DUST
2470 FARADAY AV
Lot: 0
OWNER HAGAMAN FAMILY SURVIVORS 1990 TRUST 11-07-90
Owner: BECKMAN COULTER INC
Remarks:
---
Total Time: Requested By: MATT UMBERGER
Entered By: CHRISTINE
CD Description
19 Final Structural
39 Final Electrical
~ CommenIB
------------
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
lnst2ection Histo!Y
Date Description Act lnsp Comments
12/12/2007 21 Underground/Under Floor AP JM FLOOR DRAIN
11/21/2007 17 Interior Lath/Drywall AP PY AUTOCLAVE AREA OK
11/19/2007 84 Rough Combo AP JM WALLS & HARD LID
11/02/2007 11 Ftg/Foundation/Piers AP JM AP ON 11/1/07
11/01/2007 11 Ftg/Foundation/Piers AP JM
10/29/2007 21 Underground/Under Floor AP JM
10/29/2007 22 Sewer/Water Service AP JM
FINAL REPORT FOR
SPECIAL INSPECTION AND MATERIALS TESTING
DATE: January 4, 2008
To: City of Carlsbad
Building Department
1635 Faraday Avenue
Carlsbad, California 92008
SUBJECT: SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL
INSPECTION AND MATERIAL TESTING
89443
PLAN FILE NO. N/A --------------------------------------
-PERMIT NO. CB072138 ----------------------------------------
PROJECT ADDRESS: ______ 2 __ 4 __ 7 __ 0 __ F __ a __ ra __ d __ a_..y __ R __ o ___ a,a..d .... , ..... C __ a __ rl __ s __ ba __ d_., __ C __ a __ li __ fo ___ r __ n __ ia ______________ _
We declare under penalty of perjury that, to the best of our knowledge, all the work listed below
requiring special inspection, material sampling and testing, including the off-site fabrication of
building components for the structure/s constructed under the subject.permits is in conformance with
the approved plans, the inspe~tion and observation program and other construction documents, and
the applicable workmanship provisions of the Uniform Building Code.
Executed on this 4th day of .... Ja .... n __ u ___ a __ ry ___ 20 __ 0 ___ 8 __ _
MONTH YEAR
Special Inspection and Materials Testing covered by this final report include the specific inspection and
testing services for the specific dates of October 30, 2007 and November 2, 2007. The type of special
inspection and testing services described in our Daily Field Reports is summarized as: Observation of the
installation of epoxied-in anchors, observation during concrete placement and laboratory testing of concrete
test specimens.
A. If the inspection services were provided by an approved materials testing laboratory or special inspection
agency: .
TESTING LABORATORY OR SPECIAL INSPECTION AGENCY: _____ K __ L=EI ___ N __ F __ EL=D .... E ___ R __ , ___ IN'"""'C'"'". _____ _
ADDRESS: ________ ----=5=0..:..:15"-'S=H..:,;O=R=E=H=A=M:.:..:...PL=A..:,;C=E=,-=S""-'A::..:N-=D=IE=G=O=,'--"C=A""-'9=2:..:.1=22=--------
RESPONSIBLE PROJECT MANAGER OF THE TESTING LABORATORY OR SPECIAL INSPECTION
AGENCY:
NAME (Print or Type) ______ R;;.;;;O'"'"N __ A=L=D __ C __ . __ T __ H __ O=M=S .... O __ N ____________________ _
City of San Diego Special Inspector Registration Number: #380 Expiration Date: ___ _,1=2 ..... /=31.;.../;...;0:..:.7-"'-
SIGNATURE:_-f"'_~-----=-_<c _____ .._;a;..__\.....,\....,1__...-e,..=-----------_________ _ \
RESPONSIBLE MANAGING ENGINEER OF THE TESTING LABO RA TORY OR SPECIAL INSPECTION
AGENCY:
NAME (Print or Type) ____ R_IC_K_E_. L_A....,R __ S ___ O __ N ___________________ _
State of California registration Number: RCE 39226 Expiration Date: ____ 1 __ 2 ___ / ___ 31 ___ / __ 0 __ 7 __
SIGNATURE: __ k:3 __ ~--~-~ ___ -_, ____________________ _
NMANGOLD/89443 Beckman
Copyright 2007 Kleinfelder, Inc.
Page 1 of 1 ·
Ill -KLEINFELDER
5015 Shoreham Place
San Diego CA 92122
Report No.: 4
CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT ASTM C39
Report Date: 12/3/2007
Report To: Eric Moody
Good & Roberts Inc.
1330 Park Center Drive
Last Reissued on:
Project No::
Project:
Phase:
Vista, CA 92081 Permit No.:
89443 Ref. No.:
Beckman Carlsbad
Carlsbad
N/A
£:=21~:~::u~=~~::r=~~:::z::~s=2t~~n~~~~ea~:~~~:£~~2~:~i:~~::--~:
Supplier:
Mix No.:
Palomar Transit Mix
303005
Design Strength: 3000 psi @
Date Sampled: 11/2/2007
Source of Sample: Autoclave room
Contractor:
Truck/Ticket: 1330/228418
Sampled By: Jim Allen
Submitted By: Jim Allen
Curing Method:
Specimen Prep:
Field Cure Temp (°F) Hi: Lo:
Cement Type:
Cement Factor (sk/cy):
Max. Size Agg.(in.):
Admixtures:
Date Received:
Slump(in.):
Slump w/plasticizer(in.):
Air Temperature (°F):
Mix Temperature (°F):
Air Content'(%):
Unit Weight (pcf):
Batch Size (cy):
Weather: Water Added (gal.)
Wind (MPH) Time Batched:
Measured
4
67
74
Specified
Field Cure Time: 24±4 hrs. Rh(%): Time Sampled: Time in Truck:
-=,_,.__. " ;..~sz...--=,-. ,, __ , --. -"•""' ~ --_,_ ~-. _.,. --.. -·· -· . -. -~ .......... ..,._,.,.,. =-
Sample Date Age Dimensions Area Ultimate Load Compressive Required
Number Tested (days) Diam. Ht. Len. (in2) (lbs.) Strength (psi) Strength (psi)
20355 A 11/9/200 7 6 X 12 X 28.27 67660
20355 B 11/30/20 28 6 X 12 X 28.27 107600
20355 C 11/30/20 28 6 X 12 X 28.27 106340.
20355 D 12/28/20 56 6 X 12 X 28.27
Average 28 Day Strength (psi):
All fractures were conical in nature unless noted otherwise.
Remarks:
Reviewed on 12/3/2007 by:
Unless prior arrangements have been made, all HOLD specimens will be discarded if required strength is attained.
2390
3810
3760
3790
Nikki Mangold
Lab Coordinator
As a mutual protection to our clients and ourselves, all reports submitted are the confidential property of our clients and authorization for publication of statements, conclusions, or extracts from
our reports are reserved pending our written approval.
3000
3000
3000
3000
•Ill ,KLEI ~ FE L_D ER
Construction Observation Report
Project Name J31c_e14v1 AN -e. 0 L( 1..:.-Tefc.
Client---------------Project No. (o:\ YI..(.~
Date //)-3cJ-o 7
DFR No ________ _
Project Location .;2... '-I'? O r°A-12.kblt Y R. j) • c!.J{-12L.$/3 Ao C' A 3/..!:> Time Arrived g A-rt
Contractor Gao2> ./ l<oBc~,s (!&1'15 :rR. • Bldg. Permit No. e. B & 7213 8
/..>
Time Departed / / ~rt
Reviewed by Date Reviewed _______ _ Travel Time I ffettlL
Type of Observations D Masonry
0 Welding
0 Bolting
0 Batch plant
0 Reinforcement Steel
0 Pre-Post Tensioned Tendon
0 Foundations
0 Fireproofing
0 Metal Decking
D Concrete
D Soil
J8. Other EPoxy
Documents Referenced _),_e;._;_r;.,._,_'}1.,_;=L:........c.'7_,,(--'' P.,_'/1-...,__:,:::-6_;:;E:__13c....::::..-S-_,_l____,o,::__:__,::-___,_A-_P=-J_>p._o_v--='£'--'J)=-' ....:./J_i-A-ltl. _ __c'S___.,_ ___________ _
½,,,
Summary t:JBSO-vt:i> 2. Di A-Merel l-loLES 'i>~, L.LtEo /./-,:;,~1zaAJTA-LLY //I/To EXlsr,;A/0 SLJt!r;
EAeil I-IDLE /.//9-J//NG /4J EHBE.b bi?P77-I t2F 6 '· o.e /3lff'T7l:i"~ ,/hvJ.:> oase~llc.b p(,/l)L€$ ro :,
J)olJ Al ;:-vR.. w JJ LL /2. E; .N .F,;, ,2C:/,o/6 ; 19-J,,L />£12-/) ;Fr A I L 7? l?,IJ-aP 7'S/ 0 F ,(1-/J/'RD II e.t) .P L,4,v J.
aBse,R.VJ!"/) #'3 1'?E.8M /H.ST,,J-L-le'n //1/'TD e.4CI-/ /~~E /9-r ft,?/->/€£>)< 7t,,
{-pAJ,,vc~rtoA,J...s: Uf//116 J'.1MP..seuv S'er 2-2.. ?Or# 3o/3 ?r' /,I.II w,-7# /J;JE=kl'IM-np,,,/
AA-r£ o,~ "ib'7'. ., J
Wo/2.lc bod E BY /Jc,oj) j ;tpBe2.i'Y &A12.1£..t,r_'77l.1µ, .GW<l //-LL wt'IV< ./)c>Nff CvAIF~s "
79 17/Z-#&av eh //LM-1 ,
WoRI< 1.s 0A"Go1;11G FJ-rr»,s Li>t!/J-77Z>/tJ,,
"---------. ----. -------. -------·----. ---' -----. . --------
,% Report items comply 0 Report items comply with exceptions
Kleinfelder Repr~· Signature
Representing __ ___,<:......;:;_-=..;::_._.,.-t...=.c...a==,.,,,,__ ______ _
Page j_ of J__ Kleinfelder Representative Print Name
F·1 (9/93)
KLEINf.ELUER . .
Construction Observation Report
Project Name _ ___,_]3,_,_ '---e._L-_K_,___1~_-..... '--4-'--._0-'--_---\_,__ __ L_0_u_lc.._·f_--t_, _____________ _
Client ______________ Project No. ~tz~C(,____'--f~'t_,___~--"----
Project Location __ ¼±:_~_c__a~,-~/-~~l~~-d/_"...,_J _______________ _
Contractor _______________ Bldg. Permit No.---------
Reviewed by Date Reviewed---------
Date f / / $ J O 7 J I
DFR No.---------
Time Arrived--------
Time Departed-------
lfflwl Time ~ b r' ..
lype of Observations D Masonry
D Welding
D Bolting
D Batch plant
D Reinforcement Steel
D Pre-Post Tensioned Tendon
D Foundations
D Fireproofing
D Metal Decking
D Concrete
D Soil
D Other
Documents Referenced ----------------------------------
Summary _ _-:c..~l-'r--'----+---'~-'---v_,1 _________________________ _
D Report items comply D Report items incomplete D Report items comply with exceptions
Acknowledged by ______________ _
Representing _________________ _
Page __ of __ Kleinfelder Representative Print Name
F-1 (08/06)
K L· E I N F E L D E R
Construction Observation Repo
u
Project Name f3 e c f-r ~ ct vi l c? u( 1 ~y, 13 / 45 ,· Date -=--1"~:i~~J::E~~!::::::::-__
Client-------------Project No. g '1 lf-4 '"')
Project Location __ l=-=-4....,_r-/,_,~'--""b_q,_...J"-l---~--------------
Contractor 131 g G fr i ?-t?~J /,8~~-Permit No. (. B O 7 2 I ·3 0
DFR No. _______ _
C ,.~ L ·" Time Arrived _n."""-'-~.2~v ___ _
Time Departed ~cg~: J~O __ _
Reviewed by ____________ Date Reviewed ______ _ Travel Time -~l~h.._,V"' ___ _
Type of Observations D Masonry 0 Batch plant D Foundations ~Concrete
D Welding D Reinforcement Steel D Fireproofing D Soil
D Bolting 0 Pre-Post Tensioned Tendon D Metal Decking D Other
Documents Referenced a pp Y'D U -eof p/q") I I
±S---e bet,j of MY.-P-f'Jrt;ovi~I t[Mo,_,/-edc:;-{ ,-11 cot:'lt=or/'1«'ici
v1 ~ k:) p}tihS qi-, J q bp}1'Lq b)<-e St 4l-, cf ,!Jfr4f &f
3/ Report items comply D "?: ::!=""":item, comp~ with exceptions
Acknowledged by ~ ~ ---,J<C='--"~~!.-~.=:.t.L:!q._---------
Representing Er, (E::::-C-J--U(__
Page_of __
Kl infelder Representative Si nature
)&)'7£4 G-AU-lh*,oJA\
Kleinfelder Representative Print Name
F·1 (08/06)
KJ.-AUSB'RUCKNER
AND ASSOCIATES
October 4, 2007
Carlsbad Fire & Building Departments
City of Carlsbad
1635 Faraday Ave.
Carlsbad,CA 92008
RE: Beckman Coulter -2470 Faraday Ave.
Autoclave Relocation
To Whom It May Concern:
www.KLAUSBRUCKNER.COM
PHONE! + 1 858 677 9878
FAX! + 1 858 677 9894
This letter is to confirm that relocation of the proposed Autoclave Room from Building #1 to Building #2
does not affect the control areas within the facility or any major construction as a result of hazardous
materials use for that control area.
The autoclave is used for cleaning and disinfecting empty bottles and containers using steam. The room
will be moved to an area that has been previously used for offices. Therefore the occupancy will change
from B to F-1. The sprinkler requirements will change in Building 2, Autoclave Room, as follows:
Current Requirements: Light Hazard Occupancy
0.1/1500 plus 100 gpm hose demand
Requirements Based on Change: Ordinary Hazard Group 1
0.15/1500 plus 250 gpm hose demand
Based on information provided by West Coast Fire Protection, the design density within the room was
previously overdesigned to Ordinary Hazard Group 1. Therefore there will be no proposed changes to
the sprinkler system design.
If you have any questions or need additional information, do not hesitate to call at 858-677-9878.
Sincerely,
~~-
Elley Klausbruckner
Fire Protection Consultant
4105 SORRENTO VALLEY BOULEVARD, SAN DIEGO, CA 92121