HomeMy WebLinkAbout2470 FARADAY AVE | 6200 EL CAMINO REAL; ; CB081733; PermitCity of Carlsbad \. 1635 Faraday Av Carlsbad, CA 92008 09-26-2008 Mechanical Permit Permit No: CB081733 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC#: Project Title: Applicant: Building Inspection Request Line (760) 602-2725 2470 FARADAY AV CBAD MECH 2090402800 $0.00 Lot#: Status: 0 Applied: Entered By: Plan Approved: Issued: BECKMAN COULTER-ADD 4 SPLIT Inspect Area: SYSTEM A/C COOLERS FOR PROCESSING & ASSOCIATED Owner: ISSUED 09/10/2008 RMA 09/26/2008 09/26/2008 ANDERSON AIR CONDITIONING HAGAMAN FAMILY SURVIVORS 1990 TRUST 11-07-90 1872 N CASE ST 92865 714 998-6850 Mechanical Issue Fee Install/Furn/Ducts/Heat Pumps Fee Fireplace Installation Fee Exhaust Fan Fee Installation/Relocation Vent Fee Hood Fee Boiler/Compressor to 1.5HP Fee Other Additional Fees TOTAL PERMIT FEES 4 0 0 0 0 0 5320 EL CAMINO REAL CARLSBAD CA 92008 $15.00 $36.00 $0.00 $0.00 $0.00 $0.00 $0.00 $120.00 $0.00 $171.00 Total Fees: $171.00 Total Payments To Date: $171.00 Bala.nee Due: Clearance: $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, er other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. . \ .}-.~ t,. CitJ of Carlsbad 16'.,q Faraday Ave., Carlsbad, CA 92008 760-60,2~2717 / 2?18/ 2719 Fax: 760-602-8558 Building Permit Application JOB ADDRESS 2ho ~ CT/PROJECT# LOT# PHASE# # BEDROOMS DESCRIPTION OF WORK: (Please describe present use and proposed use) 1.,..l~'i'P,u:.ATTc:J ~ fc.; .. '-'K~. ~.c,J:~S __ Co:;, L. ~ . r ~&.c, Plan Check No. (?JJ Est. Value # BATHROOMS TE~ANT B~INESS\NAME l?~acJt..~ TYPE OF CONST. occ-:-GROUP c.. 'Sf~~-;fu~~ 't:.'--.~<!..~c.A'L. BUILDING AREA (S.F) ADDITION AREA (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESD #_ NOD AIR CONDITIONING YES D NOD FIRE SPRINKLERS YES D NOD CONTAqT NAME (If Different Fam Applicant) APPLICANT NAME ADDRESS STATE ZIP PH FAX EMAIL CONTRACTOR BUS. NAME J::.,,R-~Tc"c;,J1 ADDRESS ADDRESS r "i5-"T2 . SC-: CITY STATE ZIP G-1- PHONE FAX o-c;6o FAX 7t' EMAIL ARCH/DESIGNER NAME & ADDRESS STATE LIC. # CITY BUS. UC.# STATE LIC.'89':f''1'o )_S • 12.2, ( 2. '2.. . (Sec. 7031.5 Business and Professions Code: Any City or Count)'. which requires a permit to construct, alte~ improve, demolish or reP,air any structure1 prior to its issuance, also requires the applicant for such permit to file a signed statement that he is ficensed J!ursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 1000 of Division 3 of the Business and Pro,essions Code} or that he is exempt therefrom, and the ballS for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). · ci:i@.tt?ci&m@< @@@@@roi·~tro@~ . •,_: ___ :. • ' ' . • •. t .. • • ' • ' Woi:Jiers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: g I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this penmit is issued. D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued, My workers' compensatio , insura ce carrier and policy ~-~ ., ~ 9 Insurance Co. ~Yc:'.~~ • Policy No. o,/tw l'o Cle. ' l Expiration Date O ~, O I O . This section need not be completed if the penmit is for one hundred dollars ($100) or less. a Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California, WARNING: Failure to secure worke~mpensation cover~ Is unlawful, and shall subject an employer to criminal penalties and civil fin_es up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, dam~rovided for ln,S~n 3706 of the Labor code, Interest and attorney's fees. J!5 CONTRACTOR SIGNATURE DATE o<f, ... ® W !tt@ro;m©od0!3 t1l 0@@ri.t.6 @t) u>O<i>ro . . '' . ··--·'··-·---------' ' I hereby affirm that I am exempt from Contractor's License Law for the following reason: a I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). a I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). a I am exempt under Section _____ usiness and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. a Yes a No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted wilh the following person (firm) to provide the proposed construction (include name address /phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone I type of work): J!5PROPERTY OWNER SIGNATURE DATE _g~~~~-ffi~®!J-~~~~iri~~,=~ffe?-W~"1i~~i~~ii@~t~111:,qfMb .m,f!Hl(}@O_(}!l.© . .iP:@@mJl~~:~w~-. _·:.":::, . .,,~:· Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? a Yes a No Is the applicant or future building occupant required to obtain a penmit from the air pollution control district or air quality management district? a Yes a No Is the facility to be constructed within 1,000 feet of the outer boundal)' of a school site? a Yes a No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. -:&@®9ir$Q:"J_~t?O®ro · ~@ro@r.iQJ,© ti©@69<s'1 I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address ... 0-)Gtt>-&o:i~ro:;&'ji&m'!io~o@~vo0ro~ · · · · ·. ,, • • .-, ' ' OS ',> • • ... V . ~Y. , ',111 I certify that I have read the application and state that the above information is correct and that the information on the plans is ?Ccurate. I agree to comply with all City ordinances and State laws relating to building construction. • I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Eve!)' permit issued by the Building Official under the provisions of !hi de shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such penmit ~uilding or work authorized by sue enmit is suspended or abandoned at any time· after the work is commenced for a period of 180 days (SeJtion 106.4.4 Uniform Building Code). J!5 APPLICANT'S SIGNATURE DATE~ to ~/ City of Carlsbad ·Bldg Inspection Request For: 11/03/2008 Permit# CB081733 Title: BECKMAN COULTER-ADD 4 SPLIT Description: SYSTEM A/C COOLERS FOR PROCESSING & ASSOCIATED ELECTRICAL Type:MECH Sub Type: Job Address: 2470 FARADAY AV Inspector Assignment: Phone: 7149986850 Suite: Lot: 0 ~ , Location: Inspector: ~ OWNER HAGAMAN FAMILY SURVIVORS 1990 TRUST 11-07-90 Owner: BECKMAN COULTER INC Remarks: Total Time: CD Description 44 Rough/Ducts/Dampers aCommenIB Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act lnsp Comments Requested By: NA Entered By: CHRISTINE .. \ ~ EsGH Corporation ' In <Partnersli.ip witli. (Jovernment for (Bui{aing Safety DATE: Septembe.:r. 17, 2008 JURISDICTION: Carlsbad PLAN CHECK NO.: 08-1733 PROJECT ADDRESS: 2470 Faraday PROJECT NAME: Beckman Coulter SET:I ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitt,ed for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person ~ REMARKS: Addition of (4) cooling units overhead of industrial machinery locations. By: Eric Jensen Esgil Corporation D GA D MB D EJ D PC Enclosures: 9/11 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 08-1733 Septep11ber 17, ·2008Carlsbad 08-1733 S'eptember 17, 2008 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Eric Jensen BUILDING ADDRESS: 2470 Faraday BUILDING OCCUPANCY: PLAN CHECK NO.: 08-1733 DATE: September 17, 2008 TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance --------·-·-··-------... -·· ;-::-7 !3~dg. Permit Fee by Ordina~ce --~ . --··. ---···-- Plan Check Fee by Ordinance Type of Review: [j Complete Review D Structural Only D Repetitive Fee =-; ,.. I Repeats * Based on hourly rate Comments: D Other 0 Hourly 1 J Hour* Esgil Plan Review Fee ($) $120.ool $96.001 Sheet 1 of 1 macvalue.doc 1 · .. \ ~DD ~DD ~DD ~DD lZl D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB081733 Address 2470 FARADAY Planner GINARUI2l Phone .,_,_{7...::;6-=-0)'-'6=--=0=2'-"-14 __ 6;;;...7 .... B .... , ______ _ APN: 209-040-28-00 Type of Project & Use: __ Net Project Density: DU/AC Zoning: R-A-2.5 General Plan: RLM Facilities Management Zone: 1§. CFD (in/out) #_Date of participation: __ Remaining net dev acres: __ Circle One (For non-residential development: Type of land used created by this permit: . ) Legend: [x] Item Complete &item Incomplete -Needs your action Environmental Review Required: YES D NO !Zl TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES D NO !Zl TYPE __ APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: __ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES -0 NO !81 CA Coastal Commission Authority? YES D NO !81. If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES D NO !Zl If property has Habitat Type identifje_d in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) lnclusionary Housing Fee required: YES D NO ~ (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data Entry Completed? YES D NO D (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATE!) H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev4/08 ~DD ~DD ~ D·D ~DD ~DD ~DD ~DD Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Policy 44 -Neighborhood Architectural Design Guidelines 1. Applicability: YES D NO ~ 2. Project complies: YES D NOD Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required __ Shown __ Required __ Shown __ Required __ Shown __ Required __ Shown __ Required __ Shown __ 2. Accessory structure setbacks: Front: Required __ Shown __ Interior Side: Required __ Shown __ Street Side: Required __ Shown __ Rear: Required __ Shown __ Structure separation: Required __ Shown __ 3. Lot Coverage: Required __ Shown __ 4. Height: Required __ Shown __ 5. Parking: Spaces Required __ Shown __ (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required __ Shown __ Additional Comments #1. INCLUDE A SITE PLAN SHOWING WHERE THIS PROJECT IS LOCATED, NEAREST STREETS, ETC. SEE" "SITE PLAN" ABOVE FOR THE INFORMATION REQUIRED TO BE SHOWN. #2. IS THERE AN EXISTING PARAPET WALL TO SCREEN THE NEW ROOF MOUNTED EQUIPMENT? PLEASE SHOW HOW THE EQUIPMENT WILL BE SCREENED FROM STRE~ITHIN 500'. SEE HANDOUT FOR EXAMPLE. ~~*'/L ·. {S)~ ~~ \JIA-w aL,A · OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER ~DATE ~/or H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev4/08 &a&o(ffJo ENGINEERING TITLE 24 Title 24 Report For: Beckman Coulter 2470 Faraday Avenue Carlsbad, California PROJECT DESIGNER: REPORT PREPARED BY: REO ENGINEERING 11711 Sterling Avenue, Suite H Riverside, CA 92503 (951) 343-0890 Project Number: 9963 · Date.: 9-02-08 The EnergyPro compl/ter program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commissipn for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC -www.energysoft.com EnergyPro 4.1 -By EnergySoft Job Number: 9963 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV-MM Envelope Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary Room Heating Peak Loads Room Cooling Peak Loads EnergyPro 4.4 by EnergySoft Job Number: 9963 1 2 3 12 13 15 17 19 User Number: 2298 .l 1 IPERFO~MANC.E CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-11 PROJECT NAME DATE Beckman Coulter 9/2/2008 PROJECT ADDRESS 2470 Faraday Avenue Carlsbad PRINCIPAL DESIGNER· ENVELOPE TELEPHONE Building Permit # DOCUMENTATION AUTHOR TELEPHONE Checked by/Date R.E.O. Engineering (951) 343-0890 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS IBUILDING CONDITIONED FLOOR AREA I CLIMATE ZONE 7 2,585 Sq.Ft. BUILDING TYPE [X] NONRESIDENTIAL D HIGH RISE RESIDENTIAL D HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION D NEW CONSTRUCTION D ADDITION [X] EXISTING +ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGN URE R Evers The Principal Designer hereby certifys that the proposed bu ding clesign represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 ofTitle 24, Part 6. ENV. L TG. MECH. D D D D D D D D 1. I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. 2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. 3. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ,___ ___________________ _, Required Forms ENV-1 PRINCIPAL ENVELOPE DESIGNER -NAME SIGNATURE LIC. NO. DATE · LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lig_hting C(?mpliance Not In The Scope Of Required Forms PRINCIPAL LIGHTING DESIGNER· NAME SIGNATURE LIC. NO. DATE · MECHANICAL COMPLIANCE PRINCIPAL MECHANICAL DESIGNER· NAME Run Initiation Time: 09/02/08 13:40:52 Run Code: 1220388052 EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page:3 of 20 I PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-11 PROJECT NAME DATE Beckman Coulter 9/2/2008 ANNUAL TDV ENERGY USE SUMMARY (kBtu/saft-vr) Standard Proposed Compliance ENERGY COMPONENI Design Design Margin !O Standard ·--. :-=-·.~-fro~ . ---~_:J , . Space Heating 0.00 0.00 0.00 .~~Heiltfng , ' ; I .. " Space Cooling 176.29 175.97 0.32 ' ,.spt1¢ecoo11ng: ·I , ;, . . . . . . . --· ;~ Indoor Fans 45.98 45.98 0.00 y • l~~na . ; Heat Rejection 0.00 0.00 0.00 HoatRoj~on: ·-·· Pumps & Misc. 0.00 0.00 0.00 i· • t'limpo &IC,so. · ? i' """ .~ Domestic Hot Water 16.95 17.03 -0.08 I pHW· ' •, Lighting : '[J~hling ·1 72.80 72.80 0.00 '. , ·'f ! f!ocepta_cle . ·.I. { Receptacle 83.94 83.94 0.00 ., l ! • < , . , ,, ' ;~ .. ,. ~ ' i' Process 296.16 296.16 0.00 ! .. '•• " L -r~,i,·•-',1r1 1~ 1.,....,-.,,.., .• ,_ .... ,__.,h.;;,.~,,,.t-•-i-1:.~,,-•-K•-t-1-.::.:--.i:- ' o ?O 4ll ~o .~0.1001io 1401eo·1802002202402eo.280 f TOTALS: 692.13 691.89 0.24 i . ~Btu/~qrt-yr _ _, ...,_....,, ,.,,.,, Percent better than Standard: 0.0% ( 0.1% excluding process) ·BUILDING COMPLIES GENERAL INFORMATION Building Orientation (N) 0 dea Conditioned Floor Area 2,585 sqft. Number of Stories 1 Unconditioned Floor Area 0 sqft. Number of Systems 4 Conditioned Footprint Area 2,585 sqft. Number of Zones 2 Fuel Type Natural Gas Orientation Gross Area Glazing Area Glazing Ratio Front Elevation (N' 0 sqft. 0 sqft. 0.0% Left Elevation (E 0 sqft. 0 sqft. 0.0% Rear Elevation (S 0 sqft. 0 sqft. 0.0% Right Elevation 0N 0 sqft. 0 sqft. 0.0% Total 0 sqft. 0 sqft. 0.0% Roof I olsqft. I olsqft. I o.o¾I Standard Proi;,osed Lighting Power Density ~wsqft. ~WI~ Prescriptive Env. Heat Loss o stuth Btu/h Prescriptive Env. Heat Gain o stuth-F Btu/h-F Remarks: Standard Building (Compliance) Run Initiation Time: 09/02/08 13:40:52 Run Code: 1220388052 EnergyPro 4,4 by EnergySoft User Number: 2298 Job Number: 9963 Page:4 of 20 IPER~O~MANC.E CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-11 PROJECT NAM~ IDATE Beckman Coulter 9/2/2008 ZONE INFORMATION Floor Inst. Ctrl. Allowed LPD Proc. Area LPD Credits Area Tailored Loads System Name Zone Name Occupancy Type (sqft.) (W/sf)1 (W/sf)2 · (W/sf)3 (W/sfl4 (W/sf) 3 -Clean Room Enclosures 3-Clean Rm Enclosures Office 1,830 *1.20C 5.000 Clean Room Enclosure Clean Room Enclosure Office 755 *1.20C 6.000 ' Notes: 1. See LTG-2-C 2. See L TG-4-C 3. See L TG-5-C 4. See L TG-6-C Items above require special documentation (items marked with asterisk, see L TG-2 -C by others) (by others) EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and snecial verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Si nature or Stam Run Initiation Time: 09/02/08 13:40:52 Run Code: 1220388052 EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page:5 of 20 I lcERT1FICATE OF COMPLIANCE ENV-1-CI PROJECT NAME DATE Beckman Coulter 9/2/2008 !OPAQUE SURFACES Surface Insulation Act. Cond: Joint Appendix # Type Area U-Fac. Cav. Cont. Azm. Tilt Status IV Reference Location I Comments • N, E, A, R (New, Existing, Altered, Removed) I FENESTRATION SURFACES D More than or equal to 10,000 sq.ft. of site-built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default LI-factors from Standards Table 116-A and B. Certificate shall be filed in the contracto(s Proiect office durtng construction and in the buildinA manaQe(s office after construction Act. Cond. # TvPe Area · U-Fac.1 SHGC2 Azm. Stat. GlazinQ Type (1) LI-factor Type: 116-A DefaultTable from Standards, Table Nl-1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang # Exterior Shade Type SHGC Hgt. Wd. Len. Hat. LExt.RExt. ! MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES Left Fin Dist. Len. Hat. Location/ Comments Right Fin Dist. Len. Hat. D The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W/ft2. See Section 143(c). If this box Is checked, ENV-4-C must be filled out. when submitting under the Prescriptive Compliance Approach. Run Initiation Time: 09/02/08 13:40:52 Run Code: 1220388052 EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page:6 of 20 .. !CERTIFICATE OF COMPLIANCE MECH-1-C I PROJECT NAME DATE Beckman Coulter 9/2/2008 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential AQM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately . Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space-conditioning system serving a building or space is operated for normal use, all control deviqes serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and ooeratina and maintenance information meet the reauirements of Section 10-103(b l and Title 24 Part 6. STATEMENT OF COMPLIANCE D MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. D MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. D MECH-4-A: Air-Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. D MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 ft2 of space or Jess and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. D MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. D MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA V fan volume controls installed on new or existing systems must be tested n D MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. ,Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr. -Water-loop Heat Pump Controls Applies to all new watertoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page:7 of 20 !AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-CI PROJECT NAME DATE Beckman Coulter iSYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES · Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance3 T-24 Section 112(a) 112(a) 112{b) 112(c), 115(a) 121 (b) 121(b) 121(c) 121(c) 121(c). 122(e) 122(e) 122/f\ 122(0) 123 124 144 (a & b) 144 (a & b) 144 (a & b) 144 (a & b) 144 (c) 144 (c) 144 (c) 144 (d) 144 (e) 144 /f\ 144 (f) 144 (k) 9/2/2008 AIR SYSTEMS, Central or Simile Zone 3 -Clean Room Enclosures Clean Room Enclosure 3 1 Reference on Plans or Specification 1 nla 8.00 HSPF 13.0 SEER/ 11.0 EER 13.0 SEER/ 11.0 EER n/a Yes n/a nla Yes Yes 275 cfm 113 cfm No No No No Proarammable Switch Proarammable Switch No Setback Required No Setback Required Gravitv Gravitv n/a n/a R-4.2 R-4.2 n/a n/a 0 btuh 27,540 btuh n/a n/a 65,241 btuh 32,329 btuh Constant Volume Constant Volume No No No No No Economizer No Economizer Constant Temo Constant Temo Constant Temp Constant Temp No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference ot plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves< 5,000 sqft; Has> 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF-1 for performance method duct sealing requirements. !NQTES I9 FIELD -Fgr Building Department Uu Qnly Run Initiation Time: 09/02/08 13:40:52 Run Code: 1220388052 EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page:8 of 20 IWATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-CI PROJECT NAME Beckman Coulter iSYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 Section DATE 9/2/2008 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, Hydronic Loops Reference on Plans or Specification1 MANDATORY MEASURES Equipment Efficiency Pipe Insulation 112(a) 123 1-------ll lf-------l If------- PRESCRIPTIVE MEASURES Calculated Capacity Proposed Capacity Tower Fan Controls Tower Flow Controls Variable Flow System Design Chiller and Boiler Isolation 144 (a & b) 144 (a & b) CHW and HHW Reset Controls ,_1_44~~--1 WLHP Isolation Valves f--'1'-'4'"'"4_,,_,_ __ -1 VSD on CHW, CW & WLHP Pumps > 5 HP DP Sensor Location 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section an number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater -No Pilot Light Spa Heater -No Pilot Light 113 (a) 113 (bl 113 (c) 114 (a) 114 {b) 115 (c) 115 (d) DHW Heater Bradford White M-1- 12~J¥.,SS n/a n/a n/a n/a Service Hot Water, Pool Heating Reference on Plans or Specification1 d paragraph 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section an d paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. I NOTES TO FIELD • For Building Department Use Only Run Initiation Time: 09/02/08 13:40:52 Run Code: 1220388052 EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page :9 of 20 I ), !MECHANICAL VENTILATION MECH-3-CI !PROJECT NAME Beckman Coulter !DATE 9/2/2008 I PRESCRIPTIVE REHEAT MECHANICAL VENTILATION (Section 121lbl2l LIMITATION (Section 144(d)) AREA BASIS OCCUPANCY BASIS VAVMINIMUM A B C D E F G H I ·J K L M N C" Ni::: ,-o C en CD -I C) JJ -C" :s: z '< :s: ;:a < g~ C) 0 2. en!!!. ... ->g Iii "C C) "'CJC "'CJ mi;?5· -:s:m C) CD C ~OJ -, C S: CD CQ Ill OJ'< :i' CD 3 CD "C C) ~Ill .q C) CD 0 ::I .,, am c,, 3 111 -:::1 U) en ... c. ia CD "II >< ~C) 0 C" iii CD "II >< 0 C) .,, en..., in>< O:::s >< '8 s: "II CD _, .,, ... s: "C CD 0 ... :s: .., >< C s: :i:,,cci' 31:c C JJ !=' Ou,0 ~ -m ~ C) CD "II cD°~ .,,c.,, G)O < "C CD :i' :i' ... 0 -111:s: ::I -a.is: _, ::I -~ C) ::c .... ZONE/SYSTEM ::I 0 _ .... > ... 'E.~-;:I! ..... > 0 .... ::I .,,. > :;· .... .... '< ::I S:!--=· 3-Clean Rm Enclosures 1,83( 0.15 274 18.3 15.0 275 275 275 3 -Clean Room Enclosures Total 275 275 Clean Room Enclosure 75e 0.15 113 7.6 15.0 113 113 113 Clean Room Enclosure Total 113 113 C Minimum ventilation rate oer Section 121 Table 121-A E Based on fixed seat or the areater of the exoected number of occuoants and 503/, of the CBC occuoant load for earess ourooses for soaces without fixed seatina. H Required Ventilation Air (REQ'D V.A.l is the larger of the ventilabon rates calculated on and AREA or OCCUPANCY BASIS /column D or G . I Must be areater than or eaual to H or use Transfer Air (column Nl to make up the difference. J Design fan supply cfm /Fan CFM) x 30%; or K Condition area (ft sa. l x 04 cfm/ft. sa.; or L Maximum of Columns H, J, K, or 300 cfm M This must be less than or eoual to Column Land areater that or eaual to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column I) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column I) and the Design Minimum Air (column M), column H -M. EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 1 O of 20 ,. } !MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-s-cl PROJECT NAME DATE 9/2/2008 Beckman Coulter CHILLER AND TOWER SUMMARY PUMPS Tot. Motor Drive Pump Equipment Name Equipment Type Qty. Efficiency Tons Qty GPM BHP Eff. Eff. Control DHW / BOILER ~1 IMMARY Energy Standby TANK INSUL. Rated Vol. Condition Factor Loss or Ext. System Name System Type Distribution Type Qty Input (Gals.) Status or RE Pilot R-Val. Bradford White M-I-Small Elec. No Pipe Insulation 1 10,239 12 New 0.95 n/a n/a 12UT6SS MULTI-FAMILY CENTRAL WATER HEATING DETAILS Hot Water Pumo Hot Water Pioina Lene th (ft) Control # HP Tvoe In Plenum Outside Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Condition Svstem Name Svstem Tvne ntu Outnut kW Eff. Outnut Efficiencv Status Economizer Type York F2FP024/CMB024 Split DX 3 0 0.0 .n/a 23,000 13.0 SEER/ 11.0 EER New No Economizer York F2FP036/YMB036 Split DX 1 36,000 0.0 8.00 HSPF 35,200 13.0 SEER/ 11.0 EER New No Economizer CENTRAL SYSTEM FAN SUMMARY c,11nn1 "l=.l!.l'J RETLIS:.1\11=41\1 Motor Drive Motor Drive Svstem Name Fan Tvoe Motor Location CFM BHP Eff. Eff. CFM BHP Eff. Eff. York F2FP024/CMB024 Constant Volume Draw-Through 800 0.25 64.0% 100.0% none York F2FP036/YMB036 Constant Volume Draw-Through 1,200 0.50 76.0% 100.0% none Run Initiation Time: 09/02/08 13:40:52 Run Code: 1220388052 EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 11 of 20 !ENVELOPE MANDATORY MEASURES ENV-MMI PROJECT NAME DATE Beckman Coulter 9/2/2008 DESCRIPTION Designer Enforcement [X] §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. [X] § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. [X] §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. [X] § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). [X] § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U-value according to NFRC procedures. [X] § 118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-13 between framing members. EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page:12 of 20 IMEQHA~ICAL .MANDATORY MEASURES Part 1 of 2 MECH-MMI PROJECT NAME DATE Beckman Coulter 9/2/2008 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies [X] §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. [X] §115(a) Fan type central furnaces shall not have a pilot light. [X] §123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance.with Standards Section 123. [Z] §124 Air handling duct systems shall be installed and insulated in compliance with Sections 601,602,603,604, and 605 of the 2001 CMC Standards. Controls §122(e) Each space conditioning system shall be installed with one of the following: [X] §122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or D §l22(e)18 An occupancy sensor to control the operating period of the system; or D §122(e)1C A4-hourtimerthat can be manually operated to control the operating period of the system. [x] §122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. D §122(9) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time,control device as described above. [x] §122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. [X] §122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized ·personnel. D §112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary h~ater operation when the heating load can be met by the heat pump alone. EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 13 of 20 !MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MMI PROJECT NAME DATE Beckman Coulter 9/2/2008 Description Designer Enforcement Ventilation D §121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. [Z] §122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. [Z] §122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. D §121(f)1 Air Balancing: The system shall be !)alanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or > [Z] §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or D §121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or D §l21(f)4 Another method approved by the Commission. Service Water Heating Systems D §113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. D §113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 14 of 20 IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I PROJECT NAME DATE Beckman Coulter 9/2/2008 SYSTEM NAME FLOOR AREA 3 -Clean Room Enclosures 1 830 ENGINEERING CHECKS SYSTEM LOAD I Number of S~stems I 31 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 0 Total Room Loads 2,380 56,216 3,864 151 6,512 Total Output (Btuh) 0 Return Vented Lighting 0 Output (Btuh/sqft) 0.0 Return Air Ducts 2,811 326 Cooling System Return Fan 0 0 Output per System 23,000 Ventilation 275 2,934 5,098 275 10,618 Total Output (Btuh) 69,000 Supply Fan 0 0 Total Output (Tons) 5.8 Supply Air Ducts 2,811 326 Total Output (Btuh/sqft) 37.7 TOTAL SYSTEM LOAD I 64,7721 8,9631 I 17,7811 Total Output (sqft/Ton) 318.3 Air System HVAC EQUIPMENT SELECTION CFM per System 800 § Airflow (cfm) 2,400 York F2FP024/CMB024 65,24 0 Airflow (cfm/sqft) 1.31 Airflow (cfm/Ton) 417.4 Outside Air(%) 11.4 Total Adjusted System Output I (Adjusted for Peak Design Conditions) 65,2411 ol I ol Outside Air (cfm/sqft) 0.15 TIME OF SYSTEM PEAK I Jan 11 pml I Jan 12 aml Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS <Airstream Temoeratures at Time of Heatina Peak 34.0 °F 65.8°F 110.0°F 110.0°F Supply Air Ducts S ~ ... J ... ... ~h , ,-, , ® Outside Air 275 cfm )~ 109.9°F Heating Coil Supply Fan '~ 2400 cfm I ROOMS! 69.9 °F 70.0°F ~ ,J ,; h Return Air Ducts s~ I ' r ' COOLING SYSTEM PSYCHROMETRICS {Airstream Temoeratures at Time of Coolina Peak) 83.0 / 67.8 OF 74.2/59.6°F 49.0 / 47.8 OF _ 49.0 / 47.8 °F Supply Air Ducts S ~ .... .,, .... .... '@ ~h , ~ , , Outside Air 275 cfm /~ Cooling Coil Supply Fan 50.1 / 48.2 °F '~ 2400 cfm 43.3% R.H. I ROOMSI 73.1 / 58.6 OF 72.0 / 58.2 °F ,; J ~ h Return Air Ducts g ~ I ' r ' EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 15 of 20 > IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Beckman Coulter 9/2/2008 SYSTEM NAME FLOOR AREA Clean Room Enclosure 755 ENGINEERING CHECKS SYSTEM LOAD I Number of S}'.stems I 11 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 36,000 Total Room Loads 1,084 25,770 1,594 141 2,686 Total Output (Btuh) 36,000 Return Vented Lighting 0 Output (Btuh/sqft) 47.7 Return Air Ducts 1,288 134 Cooling System Return Fan 0 0 Output per System 35,200 Ventilation 113 1,222 2,173 113 4,383 Total Output (Btuh) 35,200 Supply Fan 0 0 Total Output (Tons) 2.9 Supply Air Ducts 1,288 134 Total Output (Btuh/sqft) 46.6 TOTAL SYSTEM LOAD I 29,5681 3,7681 I 7,3381 Total Output (sqft/Ton) 257.4 AirSvstem HVAC EQUIPMENT SELECTION CFM per System 1,200 ~ Airflow (cfm) 1,200 York F2FP036/YMB036 32,329 750 Airflow (cfm/sqft) 1.59 Airflow (cfm/Ton) 409.1 Outside Air(%) 9.4 Total Adjusted System Output I (Adjusted for Peak Design Conditions) 32,3291 7501 I 27,5401 Outside Air (cfm/sqft) 0.15 TIME OF SYSTEM PEAK I Jan 11 pml I Jan 12 aml Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak 34.0 °F 66.5°F 87.8 OF 87.8 OF Supply Air Ducts S-i, .... .J .... .... -. ~h r ,-, , ® Outside Air 113 cfm )~ 87.7 °F Heating Coil Supply Fan '' 1200 cfm I ROOMS! 69.9 °F 70.0°F ~ .J .,. b Return Air Ducts 9 ~ I ' ,-,.. COOLING SYSTEM PSYCHROMETRICS lAirstream Temoeratures at Time of Coolina Peak) 83.0 / 67.8 OF 73.9 / 59.2 °F 49.0 / 47.7 °F _ 49.0 / 47.7 °F Supply Air Ducts 9 -i, .... .J .... .... '@ ~b , r , , Outside Air 113 cfm ) " Cooling Coil Supply Fan 50.0 / 48.1 °F '\ 1200 cfm 42.6% R.H. I ROOMS I 73.0/58.4 OF 72.0 I 58.0 °F .,. .J .,. h Return Air Ducts g ~ I ,.. r ' EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 16 of 20 I ROQM ~EATING PEAK LOADS Project Title !Date Beckman Coulter 9/2/2008 Room Information Desian Conditions Room Name 3 -Clean Room Time of Peak Floor Area Enclo~'.if ~O Outdoor Dry Bulb Temperature Indoor Dry Bulb Temperature 70°F Conduction Area Items shown with an asterisk (*) denote conduction through an interior surface to another room. X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Infiltration:~-1.oolx I 1.D?al x ~I -~1=.a3=ol x I 11.ool x I llgchedule Air Sensible Area Ceiling Height Fraction TOTAL HOURLY HEAT LOSS FOR ROOM U-Value o.5ool / 6~ x ACH EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Page Total: 361 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Page: 17 of 20 Jan 12 am 34°F Btu/hr ol 6.5121 6.512 I I ROQM ttEATING PEAK LOADS Project Title IDate Beckman Coulter 9/2/2008 Room Information Desian Conditions Room Name Clean Room Time of Peak Jan 12 am Floor Area Enclosflg Outdoor Dry Bulb Temperature 34°F Indoor Dry Bulb Temperature 70°F Conduction Area U-Value b.T°F Btu/hr X X = X X = x X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: ol Infiltration:~ 1.oolx I 1.0181 x I 1sslxl 11.oo[xl o.soo[ / 6~ X 35/ = 2,6861 chedule Air Sensible Area Ceiling Height ACH .6.T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 2,6861 EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 18 of 20 !ROOM C.OOLING P.EAK LOADS Project Title I Date Beckman Coulter 9/2/2008 ROOM INFORMATION DESIGN CONDITIONS Room Name 3 -Clean Room Enclosures Time of Peak Jan 11 pm Floor Area 1,830 Outdoor Dry Bulb Temperature 65 °i= Indoor Dry Bulb Temperature 729= Outdoor Wet Bulb Temperature 56 9= Conduction Area U-Value DETD 1 Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = 1. Design Equivalent Temperature Difference (DETD) Page Total ol Items shown with an asterisk (*) denote conduction through an interior surface to another room. Solar Gain Orientation Area SGF SC Weighting Btu/hr Factor X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X = Page Total ol Sched .. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor ;· 1,830 X 1.200 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 7,492 X 1,830 X 250 Btuh/occ. I 10 sqft/occ. X 1.00 = 4,575 X 1,830 X 1.750 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 10,930 X 1,830 X 5.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 31,229 0.501 / 6~ X Infiltration: ~ 1.ool xi 1.0781 X I 1,8301 X I 11.ool xi I 11! = 1,9901 chedule Air Sensible Area Ceiling Height ACH .6.. T Fraction !TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 56,2161 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occuoants ~· 1 830 · x § Btuhlocc. I ~ sqWocc. = ~ Receotacle X x Watts/sqft x Btuh/Watt = Process 0 X 1,830 x 0.000 Watts/sqft x 3.413 Btuh/Watt = Infiltration: t 1 ool xi 48341 X I 1 8301 X I 11 nnl xi o sol / 6~ x I -a aaa881 = -z11I chedule Air Latent Area Ceiling Height ACH 6W Fraction !TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 19 of20 I IROOM ~OOLING PEAK LOADS Project Title 'Date I Beckman Coulter 9/2/2008 ROOM INFORMATION DESIGN CONDITIONS Room Name Clean Room Enclosure Time of Peak Jan 11 pm Floor Area 755 Outdoor Dry Bulb Temperature 65 °F Indoor Dry Bulb Temperature 729= Outdoor Wet Bulb Temperature 56 9= Conduction Area U-Value DETD 1 Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = 1. Design Equivalent Temperature Difference (DETD) Page Total ol Items shown with an asterisk(*) denote conduction through an interior surface to another room. Solar Gain Orientation Area SGF SC Weighting Btu/hr Factor X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X = X X X = Page Total ol Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor ;x 755 X 1.200 Watts/sqft X 3.41 Btuh/Watt X 1.000 = 3,091 X 755 X 250 Btuh/occ. I 10 sqft/occ. X 1.00 = 1,888 X 755 X 1.750 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 4,509 X 755 X 6.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 15,461 o.5ol Is~ Infiltration: ~ 1.ool xi 1.0781 X I 7551 X I 11.ool xi X I 11 I = 8211 chedule Air Sensible Area Ceiling Height ACH .6.T Fraction !TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,110 I Sched. p~=:':=~=::~=a:=:=-e-n_t _G_a-in-----1 I Frac. 0 I Process Infiltration: If 1 oo I Ll:schedule Area Heat Gain xx ~755 x~50 Btuh/occ. / ~oo sqft/occ. ==-~88 0 8 x Watts/sqft x Btuh/Watt x~--~755 x 0.000 Watts/sqft x 3.413 Btuh/Watt xi 4 6341 x ~I -~Z-s-sl x 11 ool x I o sol I 6~ x I -a oooaa 1 = -2931 Air Latent Area Ceiling Height ACH 6.W Btu/hr TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 594 I EnergyPro 4.4 by EnergySoft User Number: 2298 Job Number: 9963 Page: 20 of 20 I ilYORK® Heating and Air Conditioning TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) COOLING MODELS F2RC/F2FC024 THRU 036 VARIABLE SPEED MODEL: F2FV060 F3FV060(T) c®® Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ariprimenet.org. 036-21110-002 Rev. C (1204) DESCRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application: These versatile models may be used for split-system cooling or heat pump operation. Compact cabinets along with return air options in both the upflow and horizontal positions allow this unit to fit into tight spaces such as attics, crawl spaces, and closets. ·NOTE: For matching condensing units and performance data, refer to condenser technical guides. FEATURES CABINET -The compact and sturdy cabinet is protected with a durable, attractive finish to prevent rust. The cabinet is also insulated to prevent cabinet sweating. F*RP/F2RC models have 1/2 inch fiber glass insulation and F*FP/F2FC & F*FV models have 3/4 inch insulation. BLOWERS -Blowers are sized to circulate air both quietly and efficiently. The direct-drive, 3-speed motors provide a selection of air volume to match any application. Motor speeds may be selected via quick connect terminal at the motor. Slide-out blower/motor assemblies provide for easy servicing. COILS -Using the latest in heat transfer technology, the rifled tube coil/aluminum fin coils produce high performance ratings and provide long lasting quality. The coils are capable of bot- tom return air in the upflow position, and right or left end return air in the horizontal position. FACTORY INSTALLED TXV -Air handler models F3RP(T)/ F3FP(T) & F3FV(T) have factory installed TXV metering device. All other models are orifice metered. ELECTRIC HEATERS -Models providing up to 25kw of heat are available as field installed accessories. Electric heaters are available in both single and three phase. EASY INSTALLATION -These fan coil units are designed to provide the lowest total installation cost. Accessible color coded control wiring, top and side power wiring knockouts, easy to install drain connections and electric heaters all com- bine to minimize installed cost on every job. CONTROL BOARD -The control board is equipped with low voltage terminal strips for easy installation. The control board is also equipped with plug-in receptacles for the auxiliary heaters. FOR DISTRIBUTION USE ONLY -NOT TO BE USED AT POINT OF RETAIL SALE 036-21110-002 Rev. C (1204) Physical and Electrical Data MODEL F2RC/F2FC/F2RP/F3RP(T)/F2FP Blower -Diameter Width HP Motor Nominal RPM Voltage Full Load AMPS Locked Rotor Type Filter1 Size Permanment Type Kit Shipping/Operating Weight (lbs.) -RP/FP Shipping/Operating Weight (lbs.) -RC/FC MODEL F2RP/F3RP(T)/F2FP/F3FP(T)/F2FV/F3FV(T) Blower -Diameter x Width HP Motor Nominal RPM Voltage Full Load Amps Locked Rotor Type Filter1 Size Permanment Type Kit Shipping/Operating Weight (lbs.) -RP/FP Shipping/Operating Weight (lbs.) -RC/FC 1. Field Supplied. ELECTRICAL DATA -Cooling Only MODEL TOTAL MOTOR F2RP/F3RP(T)/F2FP/F3FP(T)/ AMPS F2RC/F2FC/F2FV/F3FV(T) 208V 240V 018 (N/H) 06 1.6 1.5 024 (NIH) 06 1.6 1.5 030(N/H) 06 2.5 2.3 036 (N,H) 06 3.3 3.0 040H06 2.5 2.3 042(N/H) 06 4.4 4.0 045H06 3.1 2.6 048(N/H) 06 3.9 3.5 060(N/H) 06 4.6 4.4 VARIABLE SPEED MODEL F(2,3)FV06H06 --- 018 024 030 036(RP/FP) 9x6 10x6 10x8 10x8 1/4 1/4 1/3 1/2 1075 1075 1075 1075 208/230 1.6/1.4 1.6/1.4 2.5/2.2 3.3/2.9 3/3/2.9 3.3/2.9 6.2/5.5 7.4/6.5 Disposable/Permanent 16x20x1 16x20x1 16x20x1 20x20x1 1PF601BK 1PF601BK 1PF601BK 1PF602BK 87/92 93/98 100/105 109/115 --90/95 90/95 - 040 042 045 048 10x8 10x8 10x10 11x10 1/3 3/4 1/3 1/2 1075 1130 925 1085 208/230 2.5/2.2 4.4/3.8 3.0/2.7 3.8/3.3 6.2/5.5 11.9/10.3 4.8/4.1 4.6/4.0 Disposable/Permanent 16x20x1 20x20x1 22x20x1 22x20x1 1PF601BK 1PF602BK 1PF603BK 1PF603BK 115/121 115/121 144/150 142/148 ------- MINIMUM CIRCUIT Max. O.C.P.1 Amps/ AMPACITY 208V 240V Type 2.0 1.8 15 2.0 1.8 15 3.2 2.8 15 4.2 3.7 15 3.2 2.8 15 5.5 4.8 15 3.9 3.4 15 4.9 4.3 15 6.4 5.5 15 ----15 1. O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay Fuse. Unitary Products Group 036(RC/FC) -- 10x8 - 1/2 -- 1075 - 3.3/2.9 -- 7.4/6.5 -- 16x20x1 -- 1PF601BK --- 90/95 -- 060 F(2,3)FV060 11x10 11x10 3/4 1.0 1100 1200 4.4/3.8 7.8/7.0 8.4/7.3 -- 22x20x1 22x20x1 1PF603BK 1PF603BK 149/155 160 ---- MINIMUM WIRE SIZEA.W.G 14 14 14 14 14 14 14 14 14 14 9 ilYORK® Heating and Air Conditioning TECHNICAL GUIDE AFFINITY R-22 SPLIT-SYSTEM AIR CONDITIONERS 13 SEER MODELS: CM8018 THRU 060 (1.5 THRU 5 NOMINAL TONS) • WHEN TH5 COMPLETE CERTIFICATION APPLIES ONLY @ svsw~~~~TED C VL us LISTED Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ariprimenet.org. 036-21660-001 Rev. B (0206) DESCRIPTION The CMB Series condensing unit is the outdoor part of a versatile air conditioning system. It is designed to be custom matched with one of our complete line of evaporator sections, each designed to serve a specific function. Matching air handlers are available for upflow, downflow, and horizontal left or right application to provide a complete system. Electric heaters are available if required. Add-on coils are available for use with upflow, down- flow, or horizontal furnaces. Field installed accessories are avail- able as needed. WARRANTY 5-year limited parts warranty. 10-year limited compressor warranty. FEATURES • Superior Coil Protection -A stamped decorative metal coil guard completely protects coil from debris and other large damaging material while a polymer mesh further protects the coil against smaller particles. • Color Grilles -Engineered around the needs and wants of the consumer, Affinity units are now available with a choice of color options designed to compliment any home. • Isolated Compressor Compartment -A molded composite bulkhead isolates the compressor from the rest of the unit reducing sound and vibration. • Protected Compressors -Each compressor is protected against abnormal pressures by an internal pressure relief valve and factory installed high and low pressure controls. Additional protection against moisture and debris is provided by factory installed liquid line filter driers. • Durable Finish -Automotive quality finish provides the ulti- mate protection from harmful U.V. rays and rust creep ensur- ing long-lasting high quality appearance. A powder-paint topcoat is applied over a baked-on primer, using a galvanized, zinc coated steel base material. The result is a finish that has been proven in testing to provide 33% greater durability than conventional powder-coat finishes. • Lower Installed Cost -Designed to provide enhanced installability by featuring a slide-down control compartment and angled service valves to reduce overall installation time and cost. • Low Operating Sound Levels -A fan design boasting tech- nology adapted from aeronautic and defense engineering pro- vides for whisper quiet operation by allowing airflow to flow smoothly and efficiently across the fan tips. • Filter-Drier -A factory installed, solid core liquid line filter- drier filters harmful debris and moisture from the system. • Easy Service Access -A full end, full service, access panel with handle makes for easy entry to internal components. • Composite Base -Strong and durable composite base pan resists rust and corrosion while it helps reduce vibrations and noise. • Quiet drive system -Features combination of swept-wing fan, composite base pan, isolated compressor compartment and two-stage compressor to reduce overall sound to a mere whisper. • Low RPM fan motor -Helps to reduce airflow noise. Certified in accordance with the Unitary Small Equipment certifi- cation program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY -NOT TO BE USED AT POINT OF RETAIL SALE 036-21660-001 Rey. B (0~06) COOLING CAPACITY -With Air Handler Coils AIR HANDLER COIL1 COOLING UNIT MODEL MODEL ELECTRIC2 w MODEL RATED NETMBH I EER HEAT KW CFM TOTAL SENSIBLE SEER 1 PH 13 SEER AC WITH N1AH / MA N1AHB08 / MA08B 2,5,8, 10 / TBD 17 FC/MC18B 600 18.0 12.1 13.00 11.00 CMB01811 N1AHB12 / MA12B 5,8, 10,15,19 /TBD 17 FC/MC18B 600 18.0 12.1 13.00 11.00 N1AHB08 / MA08B 2,5,8, 10 / TBD 17 FC/MC24B 600 18.2 12.3 13.00 11.00 N1AHB12 / MA12B 5,8, 10, 15,19 / TBD 17 FC/MC24B 600 18.2 12.3 13.00 11.00 N1AHB08 / MA08B 2,5,8, 10 / TBD 17 FC/MC24B 800 23.0 16.8 13.00 11.00 CMB02411 N1AHB12 / MA12B 5,8,10,15,19 /TBD 17 FC/MC24B 800 23.0 16.8 13.00 11.00 N1AHB08 / MA08B 2,5,8, 10 /TBD 17 FC/MC30B 800 23.0 16.8 13.00 11.00 N1AHB12 / MA12B 5,8, 10,15,19 /TBD 17 FC/MC30B 800 23.0 16.8 13.00 11.00 N1AHB12 / MA12B 5,8,10,15,19 / TBD 17 FC/MC30B 1000 29.6 20.7 13.00 11.00 CMB03011 N1AHB12 / MA12B 5,8, 10, 15,19 / TBD 17 FC/MC36B 1000 29.6 20.9 13.00 11.00 N1AHC16 / MA16C 5,8, 10, 15,20 / TBD 21 FC/MC36B 1000 29.6 20.9 13.00 11.00 N1AHB12 / MA12B 5,8,10,15,19 / TBD 17 FC/MC42B 1200 35.4 26.6 13.00 11.00 CMB03611 N1AHC16 / MA16C 5,8, 10, 15,20 /TBD 21 FC/MC42C 1200 35.4 26.6 13.00 11.00 N1AHC16 / MA16C 5,8, 10, 15,20 / TBD 21 FC/MC48C 1200 36.0 27.1 13.00 11.00 CMB04211 N1AHC16 / MA16C 5,8, 10, 15,20 / TBD 21 FC/MC48C 1400 41.5 30.7 13.00 11.00 CMB04811 N1AHC16 / MA16C 5,8, 10, 15,20 / TBD 21 FC/MC48C 1600 47.5 34.2 13.00 11.00 N1AHD20 / MA20D 8, 10, 15,20,25,30 / TBD 24 FC/MC48D 1600 47.5 34.2 13.00 11.00 CMB06011 N1AHD20 / MA20D 8, 10, 15,20,25,30 / TBD 24 FC/MC60D 1800 55.5 40.0 13.00 11.00 N1AHD20 / MA20D 8, 10, 15,20,25,30 / TBD 24 MC61D 1800 56.0 40.4 13.00 11.00 1 PH 13 SEER AC WITH MV -VARIABLE SPEED CMB01811 MV12B TBD 17 FC/MC18B 600 18.3 12.0 14.00 11.50 MV12B TBD 17 FC/MC24B 600 18.6 12.2 14.00 11.50 CMB02411 MV12B TBD 17 FC/MC24B 800 23.4 16.8 14.00 11.50 MV12B TBD 17 FC/MC30B 800 23.4 16.8 14.00 11.50 MV12B TBD 17 FC/MC30B 1000 30.0 20.6 14.00 11.50 CMB03011 MV12B TBD 17 FC/MC36B 1000 30.0 20.6 14.00 11.50 MV16C TBD 21 FC/MC36C 1000 30.0 20.7 14.00 11.50 MV12B TBD 17 FC/MC42B 1200 35.6 26.2 13.75 11.00 CMB03611 MV16C TBD 21 FC/MC42C 1200 35.8 26.4 14.00 11.50 MV16C TBD 21 FC/MC48C 1200 36.4 26.9 14.00 11.50 MV20D TBD 24 FC/MC48D 1200 36.4 26.9 14.00 11.50 CMB04211 MV16C TBD 21 FC/MC48C 1400 41.0 30.2 13.75 11.00 MV20D TBD 24 FC/MC48D 1400 41.0 30.3 14.00 11.50 CMB04811 MV16C TBD 21 FC/MC48C 1600 47.5 33.6 13.50 11.00 MV20D TBD 24 FC/MC48D 1600 47.5 33.5 13.50 11.00 CMB06011 MV20D TBD 24 FC/MC60D 1800 55.5 39.1 13.00 11.00 MV20D TBD 24 MC61D 1800 55.0 39.4 13.25 11.00 1 PH 13 SEER AC WITH AHP CMB01811 AHP18 2,5,8 17 -650 18.0 12.6 13.00 11.00 AHP24 2,5,8,10 17 -655 18.2 12.8 13.25 11.00 CMB02411 AHP24 2,5,8,10 17 -830 23.0 17.1 13.00 11.00 AHP30 5,8,10 17 -795 23.6 17.2 13.25 11.00 CMB03011 AHP30 5,8,10 17 -1015 30.6 21.7 13.00 11.00 AHP36 5,8,10,15,18 17 -1040 31.0 22.2 13.25 11.00 AHP36 5,8,10,15,18 21 -1235 36.0 27.9 13.00 11.00 CMB03611 AHP42 5,8,10,15,18 21 -1255 36.0 27.9 13.25 11.00 AHP60 5,8,10,15,20,25 24 -1255 36.0 27.9 14.00 11.50 CMB04211 AHP48 5,8,10,15,20 24 -1400 42.0 31.4 13.00 11.00 AHP60 5,8,10,15,20,25 24 -1400 42.0 31.6 14.00 11.50 CMB04811 AHP48 5,8, 10, 15,20 24 -1675 48.0 35.1 13.00 11.00 AHP60 5,8,10,15,20,25 24 -1600 48.0 35.1 13.50 11.00 CMB06011 AHP60 5,8,10,15,20,25 24 -1850 55.5 40.5 13.00 11.00 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80'F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU's at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 6 1 MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2 Single phase units require single phase 4HK heaters. -,; Not applicable. Unitary Products Group . ,; ' aYORK Heating and Air Conditioning TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM HEAT PUMPS 13 SEER -R-22 MODELS: YMB018 THRU 060 (1.5 THRU 5 NOMINAL TONS) ... ARJStliod1<i/2:!D/'-4Q Unltnry K••t Pump• c@us LISTED ~: ~ ()01;0 J.:1,Gl5'\'\\~ ISO 9001 Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ariprimenet.org. . , 246809-YTG-E-0507 DESCRIPTION The YMB Series unit is the outdoor part of a versatile heat pump system. It is designed to be custom matched with one of our complete line of evaporator sections, each designed to serve a specific function. Matching air handlers are available for upflow, downflow, and horizontal left or right application to provide a complete system. Electric heaters are available if required. Add-on coils are available for use with upflow, downflow, or horizontal furnaces. Field installed accessories are available as needed. WARRANTY 5-year limited parts warranty. 10-year limited compressor warranty. FEATURES • Superior Coil Protection -A stamped decorative metal coil guard completely protects coil from debris and other large damaging material while a polymer mesh further pro- tects the coil against smaller particles. • Isolated Compressor Compartment -A molded com- posite bulkhead isolates the compressor from the rest of the unit reducing sound and vibration. • Protected Compressors -Each compressor is protected against high and low pressure as well as excessive tem- perature. This is accomplished by by the simultaneous operation of a high pressure relief valve and temperature sensors which protect the compressor if undesirable con- ditions occur. • Durable Finish -Automotive quality finish provides the ultimate protection from harmful U.V. rays as well as rust creep ensuring long-lasting high quality appearance. A powder-paint topcoat is applied over a baked-on primer, using a galvanized, zinc coated steel base material. The result is a finish that has been proven in testing to provide 33% greater durability than conventional powder-coat fin- ishes. • Lower Installed Cost -Designed to provide enhanced installability by featuring a slide-down control compartment allowing easy access to control components along with angled service valves to reduce overall installation time and cost. • Low Operating Sound Levels -A fan design boasting technology adapted from aeronautic and defense engi- neering provides for whisper quiet operation by allowing airflow to flow smoothly and efficiently across the fan tips. • Filter-Drier -A factory installed, solid core liquid line filter- drier filters harmful debris and moisture from the system. • Easy Service Access -A full end, full service, access panel with handle makes for easy entry to internal compo- nents. • Long Lasting Operation -Strong and durable composite base pan provides added strength while resisting rust and corrosion as well as reducing sound and vibration. • Complete System Control -These heat pumps utilize the unique microprocessor defrost control system to pro- vide optimal comfort as well as monitor the overall system for reliable operation. The defrost control system continu- ously monitors the space environment to maintain opti- mum efficiency. It initiates defrost only when necessary to further reduced heating costs and improve reliability. Sup- plemental heat can only operate below the balance point and then only upon need. In the event improper operating conditions occur (high temperature and/or high pressure), the will automatically shut the system down to extend the life of the heat pump. Rapid cycling is prevented by use of an internal anti-recycle timer. The defrost control features an internal memory to aid the technician in troubleshoot- ing, reducing service time and cost. Certified in accordance with the Unitary Small Equipment cer- tification program, which is based on ARI Standard 210/240 . FOR DISTRIBUTION USE ONLY -NOT TO BE USED AT POINT OF RETAIL SALE 246809-YTG-E-0507 COOLING CAPACITY -With Air Handler Coils AIR HANDLER COOLING UNIT MODEL COIL1 RATED NETMBH MODEL w MODEL CFM TOTAL I SENilBL SEER EER 1 PH 13 SEER HP WITH MA YMB01811 MA08B 17 FC/MC18B 600 17.3 12.1 13.00 11.00 YMB02411 MA08B 17 FC/MC24B 800 23.0 16.3 13.00 11.00 MA08B 17 FC/MC30B 800 23.0 16.3 13.00 11.00 YMB03011 MA12B 17 FC/MC35B 1000 28.6 20.3 13.00 11.00 MA12B 17 FC/MC42B 1000 28.6 20.3 13.00 11.00 YMB03611 MA12B 17 FC/MC42B 1200 34.6 25.0 13.00 11.00 MA14D 24 FC/MC48D 1200 35.2 25.5 13.50 11.00 YMB04211 MA16C 21 FC60C 1400 41.5 30.7 13.00 11.00 MA14D 24 FC/MC60D 1400 41.5 30.7 13.00 11.00 YMB04811 MA16C 21 FC60C 1600 47.0 34.2 13.00 11.00 MA20D 24 FC/MC60D 1600 47.0 34.2 13.00 11.00 YMB06011 MA20D 24 FC/MC60D 1800 55.0 37.9 13.00 11.00 MA20D 24 MC61D 1800 55.5 38.3 13.00 11.00 1 PH 13 SEER HP WITH MV -VARIABLE SPEED YMB01811 MV12B 17 FC/MC18B 600 17.5 12.0 14.00 11.50 YMB02411 MV12B 17 FC/MC24B 800 23.4 16.3 14.00 11.50 MV12B 1-7 FC/MC30B 800 23.4 16.3 14.00 11.50 YMB03011 MV12B 17 FC/MC35B 1000 29.0 20.1 14.00 11.50 MV12B 17 FC/MC42B 1000 29.0 20.1 14.00 11.50 YMB03611 MV16C 21 FC/MC48C 1200 36.0 25.3 14.00 11.50 MV20D 24 FC/MC48D 1200 36.0 25.3 14.00 11.50 YMB04211 MV16C 21 FC60C 1400 41.0 29.6 13.50 11.00 MV20D 24 FC/MC60D 1400 42.0 30.2 14.00 11.50 YMB04811 MV16C 21 FC60C 1600 46.0 32.7 13.25 11.00 MV20D 24 FC/MC60D 1600 47.0 33.3 13.50 11.00 YMB06011 MV20D 24 FC/MC60D 1800 55.0 37.2 13.25 11.00 MV20D 24 MC61D 1800 55.5 37.6 13.25 11.00 1 PH 13 SEER HP WITH AV/ SV / F*FV -VARIABLE SPEED YMB01811 AV24 17 -600 17.5 12.0 14.00 11.50 YMB02411 AV24 17 -800 23.4 16.3 14.00 11.50 YMB03011 AV36 21 -1000 29.0 20.1 14.00 11.50 YMB03611 AV36 21 -1200 36.0 25.3 14.00 11.50 AV/SV48 24 -1400 42.0 30.2 14.00 11.50 YMB04211 AV/SV60 24 -1400 42.0 30.2 14.00 11.50 F*FV060 24 -1400 42.0 30.2 14.00 11.50 AV/SV48 24 -1600 47.0 33.3 13.50 11.00 YMB04811 AV/SV60 24 -1600 47.0 33.3 13.50 11.00 F*FV060 24 -1600 47.0 33.3 13.50 11.00 YMB06011 AV/SV60 24 -1800 55.0 37.2 13.25 11.00 F*FV060 24 -1800 55.0 37.2 13.00 11.00 1 PH 13 SEER HP WITH AHP / SHP / F*FP YMB01811 AHP18 17 -650 17.4 12.7 13.00 11.00 F*FP024 17 -600 17.3 12.1 13.00 11.00 YMB02411 AHP24 17 -830 23.0 16.5 13.00 11.00 YMB03011 AHP30 17 -1015 28.8 20.4 13.00 11.00 F*FP040 17 -1000 28.6 20.3 13.00 11.00 YMB03611 AHP36 21 -1200 35.2 25.5 13.50 11.00 AHP42 21 -1200 35.2 25.5 13.50 11.00 AHP/SHP48 21 -1400 41.5 30.7 13.00 11.00 YMB04211 AHP/SHP60 24 -1400 42.0 30.8 14.00 11.50 F*FP045 21 -1400 41.5 30.7 13.00 11.00 YMB04811-AHP/SHP48 21 -1675 47.0 35.0 13.00 11.00 AHP/SHP60 24 -1600 47.0 34.2 13.50 11.00 YMB06011 AHP/SHP60 24 -1850 55.0 38.7 13.00 11.00 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. -Cooling MBH based on 80"F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU's at 95"F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU's during a normal annual usage period for cooling divided by the· total electric power input in watt-hours during the same period. 1 MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. -= Not applicable. Go to www.ari.org/aridirectory for the latest additional matches. Unitary Products Group 5 4 , ' .. 246809-YTG-E-0507 ' HEATING PERFORMANCE -Air Handlers UNIT AIR COIL1 ARI HEATING2 MODEL* HANDLER MODEL 47°F 17°F HSPF MBH COP KW MBH COP KW STD 1 PH 13 SEER HP WITH AHP/ SHP AHP18 -17.5 3.40 1.51 10.6 2.40 1.29 8.00 YMB01811 F*FP024 -17.5 3.40 1.51 10.6 2.40 1.29 8.00 YMB02411 AHP24 -23.6 3.20 2.16 14.6 2.20 1.94 8.00 AHP30 -29.6 3.40 2.55 18.0 2.20 2.40 8.00 YMB03011 F*FP040 -29.6 3.40 2.55 18.0 2.20 2.40 8.00 AHP36 -36.0 4.00 2.78 22.6 2.58 2.58 9.25 YMB03611 AHP42 -36.0 4.00 2.78 22.6 2.58 2.58 9.25 AHP/SHP48 -42.0 3.78 3.25 28.8 2.56 3.30 8.60 YMB04211 AHP/SHP60 -42.0 3.90 3.15 28.2 2.64 3.13 8.80 F*FP045 -42.0 3.78 3.25 28.8 2.56 3.30 8.60 AHP/SHP48 -48.0 3.72 3.78 33.4 2.58 3.79 8.50 YMB04811 AHP/SHP60 -48.0 3.82 3.68 33.0 2.66 3.63 8.70 YMB06011 AHP/SHP60 -58.0 3.60 4.72 39.0 2.40 4.76 8.05 1 Rated CFM same as for cooling. 2 Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. CP equals MBH output divided by (total KW inputx 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. -= Not Applicable. HEATING PERFORMANCE -Furnace Coils 10 UNIT COIL1 ARI HEATING2 MODEL* MODEL 47°F 17°F HSPF MBH COP KW MBH COP KW STD YMB01811 FC/MC/PC/UC18 17.5 3.40 1.51 10.6 2.40 1.29 8.00 HC18 17.5 3.40 1.51 10.6 2.40 1.29 8.00 FC/MC/PC/UC24 23.6 3.20 2.16 14.6 2.20 1.94 8.00 YMB02411 FC/MC/PC/UC30 23.6 3.20 2.16 14.6 2.20 1.94 8.00 HC30 23.6 3.20 2.16 14.6 2.20 1.94 8.00 HD24 23.6 3.20 2.16 14.6 2.20 1.94 8.00 FC/MC/PC35 29.6 3.40 2.55 18.0 2.20 2.40 8.00 YMB03011 FC/MC/PC/UC42 29.6 3.40 2.55 18.0 2.20 2.40 8.00 HC36 29.6 3.40 2.55 18.0 2.20 2.40 8.00 HD36 29.6 3.40 2.55 18.0 2.20 2.40 8.00 FC/MC/PC/UC42 35.0 4.00 2.78 22.6 2.58 2.57 8.50 YMB03611 FC/MC/PC/UC48 36.0 4.00 2.78 22.6 2.58 2.57 8.50 HC42 36.0 4.00 2.78 22.6 2.58 2.57 8.50 HD48 36.0 4.00 2.78 22.6 2.58 2.57 8.50 FC/MC/PC/UC60 42.0 3.76 3.27 29.0 2.54 3.34 8.50 YMB04211 HC60 42.0 3.76 3.27 29.0 2.54 3.34 8.50 HD60 42.0 3.76 3.27 29.0 2.54 3.34 8.50 FC/MC/PC/UC60 48.0 3.76 3.74 33.4 2.58 3.79 8.60 YMB04811 HC60 48.0 3.76 3.74 33.4 2.58 3.79 8.60 HD60 48.0 3.76 3.74 33.4 2.58 3.79 8.60 FC/MC/PC/UC60 58.0 3.58 4.75 40.0 2.40 4.88 8.00 YMB06011 MC61 58.0 3.58 4.75 40.0 2.40 4.88 8.00 HC60 58.0 3.58 4.75 40.0 2.40 4.88 8.00 HD60 58.0 3.58 4.75 40.0 2.40 4.88 8.00 1 Rated CFM same as for cooling. 2 Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. COP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. Unitary Products Group