Loading...
HomeMy WebLinkAbout2475 Wellspring St; ; CBRA2017-0290; PermitPrint Date: 09/26/2018 Job Address: Permit (_ City of Carlsbad Permit No: CBRA2017-0290 Permit Type: Parcel No: 2475 Wellspring St BLDG-Associated Permit Residentia 2081929500 Work Class: Lot#: Single Family Detached 211 Status: Applied: Closed -Finaled 11/01/2017 02/08/2018 Valuation: Occupancy Group: # Dwelling Units: Bedrooms: $530,037.77 1 5.00 Reference #: Construction Type: Bathrooms: Orig. Plan Check#: DEV2016-0039 VB Issued: Permit Finaled: Inspector: TFraz Plan Check #: 5.50 PC150042 PC2016-0067 Final Inspection: 9/26/2018 4:23:06PM Project Title: THE VISTAS Description: THE VISTAS: PHASE 10 / LOT 211 / PLAN 4 / 3,352 SF LIV / 432 SF GARAGE/ 229 SF PATIO Applicant: Owner: TOLL BROS INC JOANN EPSTINE RANCHO COSTERA LLC -2483-INACTIVE 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 725 W Town And Country Rd, 200 ORANGE, CA 92868-4723 714-347-1300 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) COMMUNITY FACILITIES DISTRICT (CFO) FEE -RES ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFO SB1473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER BENEFIT AREA FEES -B SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1 -Medium BLDG TRAFFIC IMPACT Residential Single Family w/in CFO TRAFFIC IMPACT Residential Single Family w/in CFO WATER METER FEE 1" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $33,479.41 Total Payments To Date: $28,876.31 Co-Applicant: TOLL BROS INC 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 Balance Due: $4,603.10 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $2,130.00 $1,371.72 $1,723.10 $96.00 $170.00 $110.00 $224.00 $9,646.69 $22.00 $5,099.00 $1,304.00 $934.00 $68.90 $238.00 $2,880.00 $2,800.00 $352.00 $4,169.00 $141.00 Permit Typo: BLDG-Associated Permit Residential Application Date: 11/01/2017 Owner: Work Class: Single Family Detached Issue Date: 02/08/2018 Subdivision: Status: Closed -Finaled Expiration Date: 02/20/2019 Address: IVR Number: 7407 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 08/24/2018 08/2412018 0912612018 09126/2018 September 26, 2018 Checklist Item BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLOG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs BLDG-Electric Meter 068052-2018 Release BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 070826-2018 Checklist Item BLDG-Building Deficiency BLOG-Plumbing Final BLDG-Mechanical Final BLOG-Structural Final BLDG-Electrical Final COMMENTS Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS RANCHO COSTERA LLC - 2483-INACTIVE 2475 Wellspring St Carlsbad, CA 92010-5605 Re inspection Complete Passed Yes Yes Yes Yes Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes Page 2 of 2 P~RMIT INSPECTION HISTORY REPORT (CBRA2017-0290) Permit Typo: BLDG-Associated Permit Residential Application Dato: 11/01/201 7 Owner: RANCHO COSTERA LLC - 2483-INACTIVE Work Class: Single Family Detached Issue Date: 02/08/2018 Subdivision: Status: Closed -Finaled Expiration Date: 02/20/2019 Address: 2475 Wellspring St C arlsbad, CA 92010-5605 IVR Number: 7407 Scheduled Actual Date Start Date Inspection Type Inspection No, Inspection Status Primary Inspector Reinspection Complete 03/1412018 03/14/2018 BLDG-21 051861-2018 Passed Chris Renfro Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/1012018 0411012018 BLDG-11 054409-2018 Passed Chris Renfro Complete Foundatlon/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-12 Steel/Bond 054410-2018 Passed Chris Renfro Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/06/2018 06/05/2018 BLDG-15 059843-2018 Passed Chris Renfro Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/19/2018 06/19/2018 BLDG-13 Shear 061376-2018 Passed Chris Renfro Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/05/2018 07103/2018 BLDG-84 Rough 062804-2018 Passed Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-1 4 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 07111/2018 07/10/2018 BLDG-82 Drywall, 063537-2018 Passed Tim Frazee Complete Exterior Lath, Gas Test, Hot Mop September 26, 2018 Page 1 of 2 «~> ~ CITY OF CARLSBAD RECORD CO£iX2011-0290 INSPECTION RECORD : 2415 WELLSPRING ST Building Division THE VISTAS: PHASE 10 / LOT 211 / PLAN 4 / 3. 352 SF UV / ~ 1~SPECTION RECORD CARD WITH APPROVED ANS MUST BE l(EPT ON THE .JOB 432 SF GARAGE / 229 SF PATIO DEV2016-0039 PC2016-0067 2081929500 11/13/2017 0 CALL BEFORE 3:00 pm FOR NEXT WORI( DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carl.sbadca.gov/Bullding AND CLICI< ON "Request Inspection" DATE; CBRA2017-0290 If "YES" is checked below that Division's approval is required rior to re estln a Final Building Inspection. If you have any questions please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to 760-602-8560, email to~ ectlons@carlsbadca. ov or bring in a COPY of this card to: 1635 Faraday Ave., Carlsbad. IF MARKED 'YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours IF MARKED 'YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING Fire Prevention 760-602-4660 Allow 48 hours Planning/Landscape 760-944-8463 Allow 48 hours 760-438-3891 Call before 2 pm #12 REINFORCED STEEL ELECTRIC/ EV CHARGER Date COl'YOf-CAflD flEOUlflED Jn.spector #66 MASONRY PRE GROUT #32OTEMPORARY f} -z..y \ ~ LL._ -, ,• GROUT 0 WALL DRAINS #lU TILT PANELS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME O FLOOR • CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSULATION #18 #17 #21 #24 TOP OUT • WASTE • WTR #27 TUB & SHOWER PAN #23 0 GAS TEST O GAS PIPING #25 WATER HEATER #28 SOLAR WATER BLDG-FINAL CODI? II POOLS #51 POOL EXCAV / STEEL #52 PLUMBING _!153 ELEC /CONDUIT/WIRING _l ) EQUIPOTENTIAL BOND tis{ PREPLASTER / FENCE/ ALARMS #57 GUNITE BLDG-FINAL Date Ins ector #35 PHOTO VOLTAIC #38 SIGNS BLDG-FINAL CODI! II MECHANICAL #41 UNDERGROUND DUCTS & PIPING #44 0 DUCT & PLENUM O REF. PIPING #43 HEAT-AIR COND. SYSTEMS DRYWALL,EXT LATH, GAS TES (17,18,23) #83 ROOF SH EATING, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) #85 T-Bar (14,24,34,44) BLDG-FINAL OCCUPANCY A/5 UNDERGROUND HYDRO A/5 UNDERGROUND FLUSH A/5 OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/5 FINAL F/A ROUGH-IN F/AFINAL FIXED EXTINGUISHING SYSTEM ROUGH-IN FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL MEDICAL GAS PRESSURETEST MEDICAL GAS FINAL Date Ins ector Ins ector Michael Baker INTERNATIONAL April 4, 2018 City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 Subject: Vistas -Lots 209, 210, & 211 City of Carlsbad Tract No. CT 13-03 Inspector: JN 143824 Michael Baker International has performed a field survey on April 3, 2018 to field check the building footing forms for Lots 202-205 on Wellspring Street. The results of the field survey reveal the footing forms to be within substantial confprmance, both horizontally (0.1 O'±) and vertically (0.05'.:t) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated February 9, 2016. Sincerely, Tim Thiele, P.E. Project Manager H:\PDATAI143824_ROBERTSON RANCHIADMINICORRESPNDNC\FORM CERTSITOLL BRO_FORM_PA6_CERT16_209-211.DOC PLANNING • DESIGN • CONSTRUCTION 5050 Avenida Encinas, Suite 260, Ca~sbad, California 92008 ff 760.476.9193 ff FAX 760.476.9198 Offices located throughout the Country • www.mbakerintl.com Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90631 (562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026 REGISTERED INSPECTOR'S DAILY REPORT I SWIT Job No. 150314 j Date 4/09/2018 TYPE OF D Reinforced Concrete • Structural Steel Assembly • Quality Control INSPECTION [i] Post Tensioned Concrete • REQUIRED D Reinforced Masonry • Fire Proofing • Wood Framing Asphalt • Other Job Address Lot 209 Lot 210 & Lot 211 City Carlsbad, CA Job Name Vistas @ Robertsons Ranch Permit No. CBRA2017-0228-0289-0290 J Issued By Carlsbad Type of Structure Residential Architect N/A Material Description (type, grade, source) Engineer Ian R. Waddell Phase #10 Tract# 3663 Contractor Toll Brothers Inspector's Name Raymond Mitchell Subcontractor Frontier TESTS PERFORMED TYPE OF SAMPLE SLUMP QUANTITY IN SET ADDITIONAL REMARKS ON SAMPLE INSPECTION SUMMARY -LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT-AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS (WELD MADE H.T. BOLTS.TORQUED) CHECKED, ETC. Observed reinforcing steel and tendons for lot #s 209,21 O & 211 all per details on sheet 1 M, 3T & 4SC of approved plans. Verified reinforcing steel for size, grade, lap, locations and clearances. Checked locations of embedded items and sleeves. All work observed is in accordance to approved plans and specs. Work is complete CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATION, AND APPLICABLE SECTION OF THE GOVERNING BUILDING LAWS. PT Concrete 8343448/3352 ICC CONTINUED ON NEXT PAGE 0 TIME IN TIMEOUT 2:00pm 3:00pm ... PAGE OF SAMPLES SPECIALTY NO. Approved By £ ~ .c::::: AGENCY Project Superintendent White -Office Copy • Canary -Accounting Copy• Pink-Inspector's Copy • Goldenrod -Jobsite Copy sm F-002 ©Southwest Inspection & Testing, Inc. S:\FORMS\DAILY REPORT TEMPLATES & FORMS\Reglstered Inspector's Daily Report Template·.dot .. \ o · Project N, Date: 4\2.J . _J1 \ \ ]\g \k%:'J I , __ Report No.: Auu,_,, J--rr, 1 I Liz F S S Client: 16I Soil Engineer: Unit/Phase/Lots: 1-0Ci I l\O ,z Initials: LF Date: 4/2} I B Initials: LF Date: 4/2,,}J B lnitials:.~L-F' __ _ Date: 4/2/.J B Notes: Superintendent: Contractor: Rainy Other: ____ _ Permit No. OZ.~g' C~l2AW\1CUq Footin Observation Summa : D A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil cont!itioos at the site are substantially in conformance with those assumed in the geotechnical report. A representative of LGC Valley, Inc. observed the footing excavation(s). The footing excavation(s) extend into the proper bearing strata and are in general conformance with the recommendations of the geotechnical report. 1. Footing excavations should be cleaned of loose soil and debris and thoroughly moistened just prior to placing the concrete. 2. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc. 3. In the event of a site change subsequent to our observation of footing excavations and prior to concrete placement (i.e. heavy rain, a construction/placement delay, etc.), LGC should be contacted to perform a recheck of footing excavations and site observations, as necessary. FOOTING OBSERVATION SUMMARY Print: j( White -File Copy Yellow -Client Copy Pink -Field Copy 2.0 Technician Hours LGC VALLEY, INC. Geotechnical Consulting Gold -ClienUAgency Copy