Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2483 Wellspring St; ; CBRA2017-0288; Permit
Permit Print Date: 09/20/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: Applicant: TOLL BROS INC JOANN EPSTINE 2483 Wellspring St BLDG-Associated Permit Residentia Work Class: 2081929300 Lot#: $351,324.74 Reference#: Construction Type: 1 Bathrooms: 3.00 Orig. Plan Check#: Plan Check#: THE VISTAS Single Family Detached 209 DEV2016-0039 VB 305.00 PC150042 PC2016-0067 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: THE VISTAS: PHASE 10 / LOT 209 / PLAN 1 / 2,165 SF LIV/ 430 SF GARAGE/ 153 SF CA ROOM Owner: Co-Applicant: RANCHO COSTERA LLC -2483-INACTIVE TOLL BROS INC (city of Carlsbad Permit No: CBRA2017-0288 Closed -Finaled 11/01/2017 02/08/2018 CRenf 9/20/2018 3:33:57PM 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 725 W Town And Country Rd, 200 ORANGE, CA 92868-4723 714-347-1300 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 BUILDING PERMIT FEE {$2000+) BUILDING PLAN CHECK FEE {BLOG) COMMUNITY FACILITIES DISTRICT {CFO) FEE -RES ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLOG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFD 581473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER BENEFIT AREA FEES -B SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG TRAFFIC IMPACT Residential Single Family w/in CFO TRAFFIC IMPACT Residential Single Family w/in CFO WATER METER FEE 1" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT {P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $29,104.75 Total Payments To Date: 760-720-5485 $24,501.65 Balance Due: $4,603.10 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $1,520.60 $979.27 $1,723.10 $66.00 $170.00 $92.00 $182.00 $6,394.11 $15.00 $5,099.00 $1,304.00 $934.00 $45.67 $238.00 $2,880.00 $2,800.00 $352.00 $4,169.00 $141.00 PERMIT INSPECTION HISTORY REPORT (CBRA2017-0288). , -:: : ' ' ' Permit Typo: BLDG-Associated Permit Residential Application Date: 11/01/2017 Work Class: Single Family Detached Issue Date: 02/08/2018 Status: Closed -Finaled Expiration Date: 02/18/2019 Scheduled Date Actual Start Date 08/21/2018 08/21/2018 08/22/2018 08/22/2018 09/20/2018 09/2012018 September 20, 2018 IVR Number: 7405 Inspection Type Inspection No. Checklist Item BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLDG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs BLDG-Electric Meter 067717-2018 Release Checklist Item BLDG-Building Deficiency BLDG-Fire Final 066958-2018 BLDG-Final Inspection Checklist Item FIRE-Building Final 070534-2018 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Inspection Status COMMENTS Passed COMMENTS Passed COMMENTS Passed COMMENTS Owner: Subdivision: Address: Primary Inspector Chris Renfro Dominic Flerl Chris Renfro RANCHO COSTERA LLC - 2483-INACTIVE 2483 Wellspring St Carlsbad, CA 92010-5605 Re inspection Complete ------·-- Passed Yes Yes Yes Yes Passed Yes Passed Yes Passed Yes Yes Yes Yes Yes Complete Complete Complete Page 2 of 2 S( " \yf <, t' 1 Y, s;4 </ ~ PERMIT INSPECTION HISTORY REPORT (CBRA2017-0288) :'C , ' ' 'f J Permit Type: BLDG-Associated Permit Residential Application Date: 11/01/2017 Owner: RANCHO COSTERA LLC - 2483-INACTIVE Work Class: Single Family Detached Issue Date: 02/08/2018 Subdivision: Status: Closed -Finaled Expiration Date: 02/18/2019 Address: 2483 Wellspring St Carlsbad, CA 92010-5605 IVR Number: 7405 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 03/13/2018 03/13/2018 BLDG-21 051576-2018 Passed Chris Renfro Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/10/2018 04/10/2018 BLDG-11 054403-2018 Passed Chris Renfro Complete Foundatlon/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes BLDG-12 Steel/Bond 054406-2018 Passed Chris Renfro Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 05/30/2018 05/30/2018 BLDG-15 059474-2018 Passed Chris Renfro Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/15/2018 06/15/2018 BLDG-13 Shear 061146-2018 Passed Chris Renfro Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/27/2018 06/27/2018 BLDG-84 Rough 062011-2018 Passed Chris Renfro Complete Combo(14,24,34.44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding {Decks) BLDG-24 Rough-Topout Yes BLOG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 07/03/2018 07/03/2018 BLOG-82 Drywall, 063008-2018 Passed Chris Renfro Complete Exterior Lath, Gas Test, Hot Mop September 20, 2018 Page 1 of 2 «~'> ~ CITY Of ~ECORD COPY -- CBRA2017-0288 CARLSBAD INSPECTION RECORD 2483 WELLSPRING ST Building Division I?! fNSPECTION RECORD CARD WITH APPROVED THE VISTAS: PHASE 10 I LOT 209 / PLAN 1 / 2,165 SF LIV I 430 SF.GARAGE/ 153 SF CA ROOM )'\NS MUST BE l(EPT ON THE JOB DEV2016-0039 PC2016-0067 2081929300 11/13/2017 0 CALL BEFORE 3:00 pm FOR NEXT WORI< DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760•602-2725 OR GO TO: www.carlsbadca.gov/Bulldlng AND CLICI( ON "Request Inspection" DATE: --JB CBRA2017-0288 If "YES" is checked below that Division's approval is required p_rlQr to re uest!_ng a Final Building Inspection. It you have any questions please call the applicable divisions at the 11hone numbers provided below. After all required approvals are signed off-fax to 760-602-8560, email to IJ)cfgimm.e.cJions@carlsbadci!_.goy_ or bring in a COPY of this card to: 1635 Faraday Ave., Carlsbad. :,_:,_, i'I IF MARl<ED 'YES", IT JS REQUIRED PRIOR TO ANY CONSTRUCTION STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours IF MARl<ED 'YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING Fire Prevention 760-602-4660 Allow 48 hours Planning/Landscape 760-944-8463 Allow 48 hours CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm #12 REINFORCED STEEL #66 MASONRY PRE GROUT j ')OGROUT 0 WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #38 SIGNS #11 POUR STRIPS BLDG· FINAL #11 COLUMN FOOTINGS COl'>E tr MECHANICAL #14 SUBFRAME D FtOOR D CEILING #41 UNDERGROUND DUCTS & PIPING #15 ROOF SHEATHING #44 0 DUCT & PLENUM O REF. PIPING #13 EXT, SHEAR PANELS #43 HEAT-AIR COND. SYSTEMS #16 INSULATION #18 EXTERIOR LATH #17 INTERIOR LATH & DRYWAU #82 DRYWALL,EXTLATH, GAS TES (17,18,23) Date Ins ector #83 ROOF SH EATING, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) #21 #85 T-Bar (14,24,34,44) #24 BLDG· FINAL OCCUPANCY #27 TUB & SHOWER PAN #23 OGAS TEST OGAS PIPING A/S UNDERGROUND VISUAL #25 WATER HEATER A/S UNDERGROUND HYDRO #28 SOLAR WATER A/S UNDERGROUND FLUSH BLDG-FINAL A/S OVERHEAD VISUAL CODll:U POOLS Date Ins ector A/S OVERHEAD HYDROSTATIC #51 POOL EXCAV / STEEL •A/S FINAL #52 PLUMBING F/A ROUGH-IN #53 ELEC /CONDUIT/WIRING F/AFINAL :, EQUIPOTENTIAL BOND FIXED EXTINGUISHING SYSTEM ROUGH-IN ~.,; PREPLASTER FENCE/ ALARMS FIXED EXTING SYSTEM HYDROSTATIC TEST #57 GUNITE FIXED EXTINGUISHING SYSTEM FINAL BLDG. FINAL MEDICAL GAS PRESSURE TEST MEDICAL GAS FINAL COPY OF CARD REOUl~ED Inspector Date Ins ector Date Ins ector Ins ector Michael Baker INTERNATIONAL April 4, 2018 City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 Subject: Vistas -Lots 209,210, & 211 City of Carlsbad Tract No. CT 13-03 Inspector: JN 143824 Michael Baker International has performed a field survey on April 3, 2018 to field check the building footing forms for Lots 202-205 on Wellspring Street. The results of the field survey reveal the footing forms to be within substantial conformance, both horizontally (0.1 o·~ and vertically (0.05'.:t) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated February 9, 2016. Sincerely, Tim Thiele, P.E. Project Manager H:\PDAT A\143824_ROBERTSON RANCH\ADMIN\CORRESPNONC\FORM CERTS\TOLL BRO_FORM_PA6_CERT16_209-211.DOC PLANNING • DES1t3N • CONSTRUCTION 5050 Avenida Encinas, Suite 260, Carlsbad, California 92008 # 760.476.9193 # FAX 760.476.9198 Offices located throughout the Country • www.mbakednU com .. Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90631 (562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026 REGISTERED INSPECTOR'S DAILY REPORT I SWIT Job No. 150314 I Date 4/09/2018 TYPE OF D Reinforced Concrete D Structural Steel Assembly D Quality Control INSPECTION Iii PostTensioned Concrete D Fire Proofing D Wood Framing REQUIRED D Reinforced Masonry D Asphalt D Other Job Address Lot 209 Lot 210 & Lot 211 City Carlsbad, CA Job Name Vistas @ Robertsons Ranch Penmit No. CBRA2017-0228-0289-0290 I Issued By Carlsbad Type of Structure Residential Architect N/ A Material Description (type, grade, source) Engineer Ian R. Waddell Phase #10 Tract# 3663 Contractor Toll Brothers Inspector's Name Raymond Mitchell Subcontractor Frontier TESTS PERFORMED TYPE OF SAMPLE SLUMP QUANTITY IN SET ADDITIONAL REMARKS ON SAMPLE INSPECTION SUMMARY -LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS IWELD MADE H.T. BOLTS TORQUED\ CHECKED, ETC. Observed reinforcing steel and tendons for lot #s 209,210 & 211 all per details on sheet 1 M, 3T & 4SC of approved plans. Verified reinforcing steel for size, grade, lap, locations and clearances. Checked locations of embedded items and sleeves. All work observed is in accordance to approved plans and specs. Work is complete CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATION, AND APPLICABLE SECTION OF THE GOVERNING BUILDING LAWS. SIGNATUROF REGISTERED INSPECTOR CONTINUED ON NEXT PAGE D TIMEIN TIMEOUT 2:00pm 3:00pm ~ PAGE OF SAMPLES PT Concrete 8343448/3352 ICC Approved By £ ~ """' SPECIALTY NO. AGENCY Project Superintendent White -Office Copy• Canary-Accounting Copy• Pink -Inspector's Copy• Goldenrod -Jobsite Copy sm F-002 S:\FORMS\DAILY REPORT TEMPLATES & FORMS\Registered Inspector's Daily Report Template.dot ©Southwest Inspection & Testing, Inc. Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90631 (562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026 REGISTERED INSPECTOR'S DAILY REPORT I SWIT Job No. 150314 I Date 4/09/2018 TYPE OF D Reinforced Concrete D Structural Steel Assembly D Quality Control INSPECTION Iii Post Tensioned Concrete D Fire Proofing D Wood Framing REQUIRED D Reinforced Masonry D Asphalt D Other Job Address Lot209 Lot210 & Lot211 City Carlsbad, CA Job Name Vistas @ Robertsons Ranch Permit No. CBRA2017-0228-0289-029o/ Issued By Carlsbad Type of Structure Residential Architect N/ A Material Description (type, grade, source) Engineer Ian R. Waddell Phase #10 Tract# 3663 Contractor Toll Brothers Inspector's Name Raymond Mitchell Subcontractor Frontier TESTS PERFORMED TYPE OF SAMPLE SLUMP QUANTITY IN SET ADDITIONAL REMARKS ON SAMPLE INSPECTION SUMMARY -LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS Mll=LD MADE H.T. SOL TS TORQUED) CHECKED, ETC. Observed reinforcing steel and tendons for lot #s 209,210 & 211 all per details on sheet 1 M, 3T & 4SC of approved plans. Verified reinforcing steel for size, grade, lap, locations and clearances. Checked locations of embedded items and sleeves. All work observed is in accordance to approved plans and specs. Work is complete CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATION, AND APPLICABLE SECTION OF THE GOVERNING BUILDING LAWS. SIGNATUROF REGISTERED INSPECTOR PT Concrete 8343448/3352 ICC CONTINUED ON NEXT PAGE D TIMEIN TIMEOUT 2:00pm 3:00pm ~ PAGE OF SAMPLES Approved By ~ ~ """" SPECIALTY NO. AGENCY Project Superintendent White -Office Copy • Canary-Accounting Copy• Pink -Inspector's Copy• Goldenrod -Jobsite Copy sm F-002 S:\FORMS\DAILY REPORT TEMPLATES & FORMS\Registered Inspector's Daily Report Template.dot ©Southwest Inspection & Testing, Inc. Project N. I ~·w Uiz:ts' , '~ . I Date: 4\2-J Report No.: . ~ '•, Au11,-.... ~' . I Ltz F S S Client: Toi Soil Engineer: Unit/Phase/Lots: Q.OC1 I l \ 0 1.. Initials: LF Date: 4 Jz) J B Initials: LF Date: 4-fz.J, £1 lnitials:_L_f= __ _ Date: 4/z/} S Notes: Superintendent: j Contractor: Geologist: Rainy Other: ____ _ Permit No. ozg-g- C~A ZV\1CU q Footin Observation Summa : D A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at the site are substantially in conformance with those assumed in the geotechnical report. A representative of LGC Valley, Inc. observed the footing excavation(s). The footing excavation(s) extend into the proper bearing strata and are in general conformance with the recommendations of the geotechnical report. 1. Footing excavations should be cleaned of loose soil and debris and thoroughly moistened just prior to placing the concrete. 2. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc. 3. In the event of a site change subsequent to our observation of footing excavations and prior to concrete placement (i.e. heavy rain , a construction/placement delay, etc.), LGC should be contacted to perform a recheck of footing excavations and site observations, as necessary. For L~nc. FOOTING OBSERVATION SUMMARY Print: j( White-File Copy Yellow -Client Copy Pink -Field Copy 2.0 Technician Hours LGC VALLEY, INC. Geotechnical Consulting Gold -Client/Agency Copy