HomeMy WebLinkAbout2489 OCEAN ST; ; CB881222; Permit'2 1. 0 ihórsbyaffIim that I am licensed under
ol_pcgwislone of Chapter 9 (commencing with
S.tion 7000) of Division 3 of-the Business
4. I' and Professions Code, and my license is in
L full force and effect.
(Jr I hereby affirm that I am exempt from the Contrac-tor's License Law for the following reason (Sec. 7031.5
Business and Professions Cede: Any city or County wllicr, re quires a permit to censtruci, alter, improve, demolish, or
- repair any structure. prior to its issuance also requires the ap
phicant for such permit to tile a signed statement the. ho is
licensed pursuant to the -provisions 01 the Contractors License Law (Chapter 9 commencing with Section 7000 of
Division 301 the Business and Professions Code) or that is en- enuW llueretuunu and ike oasis for ituo 4llegeo enemplian. Any -
violation of Section 7031.5 by an applicant for a permit sob'. jects the applicant to a civil penalty 01001 more than live hun-
dred dollars ($500). .-
'
I I. as owner of the property. or my employees with wages
as their sole eompnnsation. will do the work, and the strut tory is not intended or offered for univ ISec 7044. Ravinvsn
and PrnlgSsions Code: The. Cent rectors License Law does
not apply to an owner of property who builds or improves
- thereon and who done coch work himcelt or through his Own
employees, provided that such improvements are not intend ed or uttered for sale. If. however, the building or improve-
ment is sold within one year of completion, the owner-builder will have the burden of proving -that he did not build or im-
prove for the purpose 01 sale).
It I, as owner of the property. -am exclusively contracting
with licensed contractors 10 construct the project (Sec. 7044.
Business and Professions Cede: The Contractor's License Caw does net apply loan owner 01 property who builds or im-
proves, thereon, and who contracts for each projects with a contractor(s) license pursuant to the Contractor's License Law).
fl As a homeowner lam improving my home, and the 10110w- - 'I
ing conditions exist: .1. The work is being performed prior to sole.
I have lived in my home ter twelve months prior 16 completion 01 this work.
I have not claimed this exemption during the'-last three years.
0 lam exempt coder Sec. ___________________ . B & P.C.
for this reason
O thereby affirm that .1 have a certificate of c00505l to
sell-mourn, or a certificate 01 Workers' Compensation In..
- surance. or a certified copy thereof (Sec. 3800. Labor Code)
POLICY NO. -'
COMPANY,
-- D-Copy Is tiled with the ci1y.
certified copy is hereby furnished - -
CERTIFICATE OF EXEMPTION FROM
- - WORKERS' COMPENSATION INSURANCE
(This,00ction need not be completed it the permit
is for one hundred dollars (Stool or less) - I
tcenity that in the performance of the work for which
this permit in issued. I shall not employ any person In any
manner no an to become subject to the Workers' Compen'
nation Laws 01 California.
NOTICE TO APPLICANT: Ii.'alter making Ihik Certificate
01 Esemplion, you should become subject to the WOrkern'
Compensation provisions of the Labor Code, you must,
-forthwith comply with-such provisiono or this permit shall
- be deemed revoked.
I" 0 I hereby affirm that there in a construction lending
agency tot the perlorniance orson work iot which 11510 per.
0 mit is issued (Sec. 3097. Civil Code)
MI Lender's Name.
.- Lender's Address -
to
lICE RAil PflIIdT PEN flNIV A PR HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr., Carlsbad, CA 92009-1915 (619) 438-1161 APPLICATION & 'PERMIT
JOB ADORCSS AV. D. THOMAS BROS NO, FA I ON BUSINESS LICENSE C 1
La BLOCK CONTRACTORS PHONE C
- . I 71 IZ 79'ONTRACTOR
CTOR'S AODACSS STATE LICENSE NO. fr I .
OWNER'S MAILING AOORB8
R DESIGNER'S PHONE
- -- I
DESCRIPTION dF WORK —
-R'S ADDRESS STATE LICENSE NO.
OS NAME I OWNE B'S PMOM
PUE-10
A4 f/p FLRELEV.NO 0CC GP i
ALUATION PERMIT NUMBER
-________________
Zola
BUILDING SO. FOOTAGE
9687 09/11/89 0001 01 02STORIES C-PRMT109..0-
Not Valid Unless Machine Certified
TRACT PARKING SPACE RES UNITS GRADING PERM REDEVELOPMENT
CONSTCENSUS
vii NI] —
AREA
YO NO
FIRE SPR
Y 0
TYPE
I
0CC LOAD
I vJ NO
QTY. PLUMBING PERMIT,- ISSUE ' 7 Si) OTY. MECHANICAL PERMIT - ISSUE OO - SUMMARY/ACCOUNT NUMBER —
-
EACH FIXTURE TRAP . —
INSTALL FURN. DUCTS UP TO 100,000 BTU BUILDING PERMIT 001'810-00'00'8220 if)
EACH BUILDING SEWER , - OVER 100,000 BTU , SIGN PERMIT 001'810'00'00'8221 F
EACH WATER HEATER ANDiOR VENT , -
BOILER/COMPRESSOR UP TO 3 HP - PLAN CHECK 001-810-00-00-8891
—
EACH GAS SYSTEM 110 4 OUTLETS , —
BOILER/COMPRESSOR 3.15 HP ' , ' TOTAL PLUMBING 001'810-00'00'8222
—
EACH GAS SYSTEMS OR MORE , METAL FIREPLACE , ELECTRICAL 001,81,O:00008223
—
EACH INSTAL., ALTER, REPAIR WATER PIPE , —
VENT FAN SINGLE DUCT . MECHANICAL 001'810-00'00'8224
—
EACH VACUUM BREAKER - , — MECH EXHAUST H000'DUCTS , MOBILEHOME 001'810'00-00-8225 -
-
WATER SOFTNER , ' -
RELOCATION OF EA FURNACE/HEATER . - - SOLAR 001-810'00'00'8226
—
EACH ROOF DRAIN IlNSIDEI . -
DRYER VENT ' STRONGMOTION 880-519-92-33
-' TOTAL MECHANICAL
1 .
FIRESPRINKLERS 001-810-00-00-8227
TOIALPLUMBING I .
PUBLIC FACILITIES FEE 320-810-00'00'8740
QTY. ELECTRICAL PERMIT - ISSUE , •"9 OTY. MOBILE HOME SETUP
BRIDGE FEE 360-810-00-00-8740
PARK-IN'LIEU (AREA ). . -
NEW CONSTEAAMP'SWlSKA CAR PORT . TIF 312-810-00-00-8835
— IPH 3PH - , AWNING --, LA COSTA hF - 311-810-00-00-8835 -
EXIST BLDG EAAMPISWT'BKR GARAGE - . - . FMF
1 PH 3 PH. . - LICENSE TAX 001-810-00-00-8162
REMODEL'ALTER PER CIRCUIT . ' . . MFF 880-519-92-57
—
TEMPPOLE200AMPS
—
OVER 200AMPS
- tEMP OCCUPANCY (30DAYS)
CREDIT DEPOSIT JE - TOTALELECTRICAL I_- -
- TOTAL ' TOTAL FEES PAYA J,,g-71/0_q
I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PEMlT" AND DO HEREBY I Expiration. Every permit issued bythe Building Official under the provisions Ofthis *ANOS!jPt'RM:TISREQUIEO FOR EXCAVATIGNS OVER
('.FRTIFY tINDER PENALTY OF PFR.tI tRY THAT All. INFORMATION HEREON INCLUDING THE Code shaft expire by limitation and become null and void, tithe building or work 510 EP AND DEMdX.rrION 000 CONSTRUCTION OF
,
author lzedbyou'Pu_eiiiiit _6notcommencedwithin180 ddyhfrUiuithedateofOuch s iu TORIES IN HEIGHT DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CRTIFY AND AGREE If A PERMIT lb permit, or - ho building or work authorized by such permit in suspended or
ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON' abondo_timea_tarfheworkinCommencedfora _nodof100days
DRES OVER 3 STOR______
-D)/11/ STRUCTION, Wl'bETI-lR SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND OWNE\CONTRACTOR APP
?b BIN KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND APP
BY PHONE 173 EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ,"
GRANTING OF THIS PERMIT..-. -.
TYPE DATE INSPECTOR
BUILDING
FOUNDATION
REINFORCED STEEL
MASONRY
GUNITE OR GROUT
SUB FRAME 0 FLOOR 0 CEILING
SHEATHING 0 ROOF 0 SHEA
FRAME
EXTERIOR LATH
INSULATION
INTERIOR LATH & DRYWALL
PLUMBING
SEWER AND BL!CO 0 PLICQ
UNDERGROUND 0 WASTE 0 WP'TER
TOP OUT 0 WASTE 0 WATER
TUB AND SHOWER PAN
GAS TEST
O WATER HEATER 0 SOLAR WATER
ELECTRICAL
ELECTRIC UNDERGROUND 0 UFFER
ROUGH ELECTRIC
ELECTRIC SERVICE 0 TEMPOR4RY
O BONDING 0 POOL
MECHANICAL
DUCT & PLEM., 0 REF. PIPING
HEAT - AIR COND. SYSTEMS
VENTILATING SYSTEMS .
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE
ITEMS ABOVE HAVE BEEN APPROVED
FINAL
PLUMBING
ELECTRICAL
MECHANICAL -
GS :\
BUILPAHG
SPECIAL CONDITIONS \
\. \ I ...
-' - FIELD INSPECTION RECORD r
REQUIRED SPECIAL INSPECTIONS INSPECTORS NOTES
REQ. IF INSPECTORS INSPECTION CHECKED APPROVAL DATE
f
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP
STRUCTURAL CONCRETE
OVER 2000 PSI
PRESTRESSED
CONCRETE
POST TENSIONED
CONCRETE
FIELD WELDING
HIGH STRENGTH
BOLTS
SPECIAL MASONRY
PILES CAISSONS
87
' .:...c.
T-7
DEVELOPMENT PROCESSING SERVICES DIVISION
2075 LAS PALMAS DRIVE
CARLSBAD, CA 92009-4859.
(619)438-1161
MISCELLANEOUS FEE RECEIPT
Applicant Please Print And Fill In Shaded Area Only
JOB
ADDRESS4_T PLAN ID. NO.' j
- Q 2 1— 09
ASSESSOR'S
PARCEL PARCEL NO.26)'5 ) ALS ?AYLE OWNER
1877 MUM 0001 01 05 OWNER'S MAILING 6?9 if.. re,z ADDRESS ' Misc 70.00
. VALIDATI9N AREA CITY S'COTT~' L)/'LE ZIP 7T.2,,cI TEL.2-9..q5 -
CONTRACTOR
ESTMATED VALUATION
001-810-00-00-8821 7o CONTRACTOR'S
MAILING
ADDRESS PLAN CHECK FEE
IF THE APPLICANT TAKES NO ACTION
WITHIN 180 DAYS, PLAN CHECK FEES
CITY ZIP TEL. WILL BE FORFEITED.
STATE BUSINESS
LICENSE NO. LICENSE NO. 5ç
SUBDIVISION LOT(S)
LEGAL DESCRIPTION L1..,1_- .7P17 .. CHECK IF SUBMITTED:
o 2 ENERGY CALCS
El 2 1987 ENERGY CALCS
FOR NON RESIDENTIAL BLDGS
DESCRIPTION OF WORK o 2 STRUCTURAL CALCS
i-41P1-ovE £ET,4ift//,U4 t4j-L.. ox ,1354-c" 0 2 SOILS REPORTS
0 2 SELF ADDRESSED ENVELOPES
DATE GIVEN! DATE , SENT TO APPLICANT
/4,2Is rL'
CONTACT PERSON WE I T H g T L. E LA COSTA LETTER
ADDRESS Z/? q/L) ST SCHOOL FEE FORM
(412L . VYOTEL.')a P & E CORRECTIONS LIST CITY ZIP
CERTIFICATE OF OCCUPANCY
APPLICANT'S SIGNATURE / -
DATE
White- File YellowS Applicant Pink - Finance Gold - Assessor
d 2- 2- ~Wvnu 41* .
If
LD EPORT.
'To
/
DATE I / PROJECT NO.
99. /
PRO2 1
LOc
CONTRACTOR OWNER -
WEATHER TEMP.
PRESENT AT SITE
SUMMARY OF INSPECTION:
1) v
Alt- lcxwr3a~~
'J 4;7 2 hrer
2 -
€ 1-
,
41 ?1rv'/' •
..
RECOMMENDATIONS: 4)
% 4j e4f '4
4. ZZ i4A7 a
j7
HETHERINGTON ENGINEERING, INC.
'BJIGNATURE 42.i44. d SOIL & FOUNDATION ENGINEERING
ENGINEERING GEOLOGY • HYDROGEOLOGY
(619) 931-1917
COPIES TO: " 1 5245 Avenida Encinas, Suite G.
- Carlsbad. California 92008
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 5601468
DATE:
JURISDICTION: _________________
PLAN CHECK NO: V2i2...2.. SET:
PROJECT ADDRESS:Z4 O0-ea S--
PROJECT NAME:________________________________
R
APPLICANT
JURISDICTION
PLAN. CHECKER
[]FILE COPY
DUPS
[]DESIGNER
E The plans transmitted herewith have been corrected. where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified 'ce'arncks br-tovi are resolved and
checked by building department staff.
.The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected ...plans are submitted for recheck.
IJ The applicant's copy of the check list is enclosed for the
jurisdiction to return to. the applicantcoñtact person.'
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
0 Esgil staff did advise applicant that the plan check has
been completed. Person contacted:_______________________
Date contacted:
In REMARKS:______
By&j1jjj( I VQ.,.C40-4.
ESGIL CORPORATION
0 GA . 0 AA 0 vw 0DM
Telphone #________________
-covn *Ae S, 0i ery1c,
ce V ( e ,u am
'.cs a.rvic( +\'le' acs-y -yv
lJv\ LS .So
nclosures: ...
ESG1L CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: PT Q'Z
ArrJ:
JURISDICTION: C.ii-.., op FL50
PLAN CHECK NO: 1212. SET:
PROJECT ADDRESS: 124- Oc&i
PROJECT NAME: t>eAVJLL
.PPLICANT
JURISDICTION
Li PLAN CHECKER
OFILE COPY
!-,UPS
ODESIGNER
G The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building-codes when minor deficien-
cies identified 00MTAC4E.D - AL30 EEELO) are resolved and
checked by building department staff.
D The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
E) The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
0 The applicant's copy of the check list has been sent to:
Esgil staff didnot advise the applicant conta4on/at
plan check has been completed.
Esgil staff did advise applicant that the plan che has
been completed. Person contacted: 5aa ReL. N--, _______________________
Date contacted: Telephone *________________
REMARKS: CART :_M.AP.TLE _CALLC_)-4 _LD
AEDIFW COULD_1ri'.'I %.Ar' _IJDtC..aTED
30 IL- CE PJC,Q..Ui I'LL P_I.D LEc _I TEM _CD*)(7E
ATrAxAF-io) t, TPAT 4S wo Ila,_OTE_To_C.0VE2.. IrSLA
By: I _Th
ESGIL COORATION
---- ., WI.% 10 kETORJJ PLAi5 To
os.'4i AlT ,1L3WA. _rI-AT_OP A PcsoJ
OJLDL1)<ETO A:5r. ACCOLfIrE;
CITY OF CARLSBAD
PLAN CHECK NO. 88-1222
2489 OCEAN ST.
SEAWALL
SEPTEMBER 19, 1988
Footings do not extend 3 ft. into bedrock as required by the
soils investigation report.
Provide a letter from the soils engineer stating that he has
reviewed the plans to confirm conformance with the recommendations
of the soils report.
Note on plans that: "Prior to the contractor requesting a
Building Department foundation inspection, the soils engineer
shall advise the Building Official in writing that the foundation
excavation, forming and reinforcement comply with the soils
report and the approved plans.
Please make any changes on tracings and submit two new sets
of prints to Esgil Corporation, 9320 Chesapeake Dr., Suite 208,
San Diego, CA 92123
If you have any questions, please:-.contact Gene Meier of Esgil
Corporation at (619) 560-1468. Thank you.
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: SE.Fr iq ,
JURISDICTION: Crr',' OF CIRLAD
PLAN CHECK NO: 1222 SET: -
PROJECT ADDRESS: EIL) ST.
PROJECT NAME: SEAAJALL
FILE COPY
UPS
DESIGNER
ON
E The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
D The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
D The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction .to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
RLE TL1
24 OCeA-.) T.
CA, ILS&c 0 200r
0 Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted: 1 I-fAiL
Date contacted: Telephone #________________
0 REMARKS:
/
By: Enclosures:
ESGIL CORPORATION
I
Footings
soils /
ea Provi
CITY OF CARLSBAD
PLAN CHECK NO. 88-1222
2489 OCEAN ST.
EAWALL
£SEPTEMBER 19, 1988
/ I
b'not extei3/3 into bedrock as required by the
stigation 0
b_
etter from the soils engineer stating that he has
revi we t e lans to confirm conformance with the recommendations
of t soi report.
Note on p1 ns that: "Pr6 ontractor requesting a
Building Department foundation nspection, the soils engineer
shall advise the Building ficial in writing that the foundation
excavation, forming and ei rcement comply with the soils
report and the approv .
Please make any changes on tracings and submit two new sets
of prints to Esgil Corporation, 9320 Chesapeake Dr., Suite 208,
San Diego, CA 92123
If you have any questions, pleasecontact Gene Meier of Esgil
Corporation at (619) 560-1468. Thank you.
Datei
Prepared byi
Jurisdiction LAc -
o Bldg. Dept.
VALUATION AND PLAN CHECK FEE D Esgil
*
di
PLAN CHECK NO._IM -I2.2-
BUILDING ADDRESS -4- Oc&, &r.
APPLICANT/CONTACT CI-&RLE.-, 1&cL PHONE NO. &lq 72' (0544
BUILDING OCCUPANCY DESIGNER PHONE____________
TYPE OF CONSTRUCTION CONTRACTOR PHONE___________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
140uL : 2HR5 '-1,25
Air Conditionine
Commercial
-
Residential
Res. or Comm.
Sprinklers -Fire
Total Value
Building Permit Fee $_ S
Plan Check Fee S $
CON I1CNTS Ec.IL..
SHEET OF
12/87
BUILDING PLANCHECK
ENGINEERING CHECKLIST
DATE: 8/21/89
PLAN CHECK NO. 6,9/22Z
PROJECT ADDRESS:
25/9? O 5r
LEGEND
ITEM COMPLETE
ITEM INCOMPLETE -
NEEDS YOUR ACTION
N/A - NOT APPLICABLE
PROJECT NAME: _qgy 5EMaLL..
LEGAL REQUIREMENTS
Site Plan
0 0 1. Provide a fully dimensioned site plan drawn to scale. Show:
north arrow, property lines, easements, existing and proposed
structures, streets, existing street improvements, right-of-way
width and dimensioned setbacks.
U 2. Show •on site plan: Finish floor elevations, pad elevations,
elevations of finish grade adjacent to building, existing
topographical lines, existing and proposed slopes, driveway with
percent (%) grade and drainage patterns.
0 0 U 3. Provide legal description and Assessors Parcel Number.
Discretionary Approval Compliance
No discretionary approvals were required.
Project complies with all Engineering Conditions of Approval
for Project No.___________________
Project does not comply with the following Engineering
Conditions of Approval for Project No.
Conditions complied with. by: Date:_________
Field Review
Field review completed. No issues raised.
Field review completed. The following issues or discrepancies
with the site plan were found:
Site lacks adequate public improvements.
Existing drainage improvements not shown or in cbnflict with
site plan.
Site is served by overhead power lines (Future Improvement
Agreement required).
Grading is required to access site, create pad or provide
for ultimate Street improvement.
Site access visibility problems exist. Provide onsite
turnaround or engineered solution to problem.
Other:_______
Dedication Requirements
No dedication required.
Dedication required. Please have a registered Civil Engineer
or Land Surveyor prepare the appropriate legal description
together with an 8-1/2" x 11" plat map and submit with a title
report and the required processing fee. All easement documents
must be approved and signed by owner(s) prior to issuance of
Building Permit. The description of the dedication is as
follows:
Dedication completed, Date: By:________________
Improvement Requirements
No public improvements required. SPECIAL NOTE: Damaged or
defective improvements found adjacent to building site must be
repaired to the satisfaction of the City inspector prior
to occupancy.
Public improvements required. This project requires
construction of public improvements pursuant to Section 18.40 of
the City Code. Please have a registered Civil Engineer prepare
appropriate improvement plans and submit for separate plan check
process through the Engineering Department. Improvement plans
must be approved, appropriate securities posted and fees paid
prior to issuance of permit. The required improvements are:
Improvement plans signed, Date: By:
Improvements are required. Construction of the public
improvements may be deferred in accordance with Section 18.40 of
the City Code. Please submit a recent title report on the
property so we may prepare the necessary Future Improvement
Agreement. The Future Improvement Agreement must be signed,
notorized and approved by the City prior to issuance of a
Building Permit.
Future Improvement Agreement completed, Date:
By:____________
Grading Requirements
13a. Inadequate information available on site plan to make a
determination on grading requirements. Please provide more
detailed proposed and existing elevations and contours.
Include accurate estimates of the grading quantities (cut,
fill, import, export).
14. No grading required as determined by the information provided
on the site plan.
____ 15. Grading Permit required. A separate grading plan prepared by
Pe2 Be. a registered Civil Engineer must be submitted for separate
plan check and approval through the Engineering Department.
NOTE: The Grading Permit must be issued and grading
,i substantially complete and found acceptable to the City
I Inspector prior to issuance of Building Permits.
Grading Inspector sign off. Date: By:_____________
Miscellaneous Permits
Right-of-Way Permit not required.
Right-of-Way Permit required. A separate Right-of-Way Permit
issued by the Engineering Department is required for the
following:____________________________________________________________
Sewer Permit is not required.
- 19. Sewer Permit is required. A Sewer Permit is required concurrent
with Building Permit issuance. The fee required is noted below
in the fees section.
_____ 20. Industrial Waste Permit is not required.
21. Industrial Waste Permit is required. Applicant must complete
Industrial Waste Permit Application Form and submit for City
approval prior to issuance of Building Permits. Permits must
be issued prior to occupancy.
Industrial Waste Permit accepted -
Date: By:___________
Fees Required
t3i4 22. Park-in-Lieu Fee
Quadrant:-..---. Fee Per Unit: - Total Fee:__________
23. Traffic Impact Fee
Fee Per Unit: - Total Fee:__________
I'
24. Bridge and Thoroughfare Fee
Fee Per Unit: - Total Fee:'Xd4,
____ 25. Public Facilities Fee required.
44 26. Facilities Management Fee Zone: Fee:
____ 27. Sewer Fees Permit No. EDU's: 4t7,g
Fee:______
'Ik 28. Sew~;~
Fee: ral required:_________________________
____ REMARKS: A)01
ENGINEERING AUTHORIZATION TO ISSUE PERMIT
BY: Date:_______
/ /
nish floor elevations, elevations of finish
ng, existing topographical lines, existing
veway and percent (%) grade and drainage
ENGINEERING CHECKLIST
a, LEGEND
Date: 9 27S8 Item Complete Plan Check No. 813/22Z
Project Address: 211 91 t%elqla dr. Item Incomplete - Needs
Project Name: 5ienv Your Action
Number in circle 1,2,3 Field Check Date: indicates plancheck By: number that deficiency
was identified
LEGAL REQUIREMENTS
Site Plan a,
1. Provide a fully dimensioned te plan drawn to scale. Show: North
F1 arrow, property Iinea easements, existing and proposed
structures, streets , tfflg street improvements, right-of-way width and dimensioned socks.
Show on Site Plan:
grade adjacent to b
and proposed slopes
patterns.
b ,' Provide legal descp
Provide assessortrcnmv
i PERMITS REQUIRED Ii 1
Grading pJrequired. (Separate submittal to Engineering
Department -duted for Grading Permit).
Grading plans in plan check PE 2.83?
Need the following completed prior to building permit issuance:
Grading plans signed.
Grading permit issued.
Grading completed.
Certification letter and compaction reports submitted.
Grading inspected and permit signed off by City Inspector.
Right-of-Way Permit required for work in public right-of-way
(e.g., driveway approach, sidewalk, connection to water main,
etc).
Grading
S.
uPr 0 0 9. Industrial Waste Permit application required. To be filled out
completely and returned to Development Processing.
FEES REQUIRED
10. Park-in-Lieu fees required.
Quadrant: -, Fee Per Unit: Al Total Fee:______
D 0 11. Traffic impact fee required.
Fee Per Unit: , Total Fee:
_____
'/ 0 0 12 Bridge and Thoroughfare fee required.
Fee Per Unit: -._--, Total Fee:
- 11
REMARKS:
O.K. to issue: Date:
If you have any questions about any of the above items identified on this plan
check, please call the Development Processing Department at 438-1161.
Vil
We-
Public facilities fee required.
V00 Facilities management fee required. Fee:__________
IS. Additional EDU's required: _
'permitn0 Sewer connection fee: S
zD .D
16. Sewer lateral required: #4)
Plan Check No. A5/222, Address ZVB? Qa' C;>-7-
Type of Project and Use 5JCLL.L
Zone R- 3 Use Allowed? YES ( NO
Setback: Front 0$. Side 61c Rear
Facilities Management Zone I
School District: San Dieguito Encinitas
Carlsbad IX San Marcos
Discretionary Action Required YES NO Type
Environmental Required YES NO
Landscape Plan Required YES NO
Comments
Coastal Permit Required YES NO
Additional Comments
Ix
r.i m 1: $
U U U o_ (L o
UR
PLANNING CHECKLIST
OK TO ISSUE DATE
Plan Check No.
APN:
PLANNING CHECKLIST
Address Z-,y 67 odd'*4 ¶11-
Planner TZ.( C- /tl UNOJE Phone 438-1161
(Name)
Type of Project and Use
Zone 3 Facilities lbnagement Zone
'S
"S
Legend
Sd Item Complete
Item Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number that deficiency
was identified
Environmental Review Required: YES NO _____ TYPE
DATE OF COMPLETION: NO LI, /5' J
Compliance with conditions of approval? If not, state conditions which
require action.
Conditions of Approval
Discretionary Action Required: YES NO TYPE
APPROVAL/RESO. NO. DATE:
PROJECT NO.
OTHER RELATED CASES:
fl Compliance with conditions of approval? If not, state conditions which
require action.
Conditions of Approval
Landscape: YES NOf DATE OF A.0?ROV.L:
O 0 0 Compliance with conditions of approval? If not, state conditions which
require action.
Conditions of Approval
1•1.1
Coastal: YES NO ____ DATE OF APPROVAL:
Compliance with conditions of approval? If not, state conditions which
require action.
Conditions of Approval
Show on Site Plan: Finish floor elevations, elevations of finish
grade adjacent to building, existing topographi:çal lines, existing
and proposed slopes and driveway.
Provide legal description of property.
Provide assessor's parcel number.
Setbacks:
Front: Required Shown
I nt. Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Lot coverage: Required Shown
Height: Required Shown
Parking: Spaces Required Shown
Guest Spaces Required Shown
Additional comments and remarks have been made on the building plans. These
marked-up plans may be picked up at the Building Department. These marked-up
plans must be resubmitted with the revised plans for this project.
Have plans been marked up? YES N
Additional Comments
K TO ISSUE DATE
PLNCK. FRM
Site Plan:
1. Provide a fully dimensioned site plan drawn to scale. Show:
North arrow, property lines, easements, existing and proposed
structures, streets, existing street. improvements, right-of-way
width and dimensioned setbacks.
STATE OF CALIFORNIA—THE RESOURCES AGENCY GEORGE DEUKMEJIAN, Governor
CALIFORNIA COASTAL COMMISSION
SAN DIEGO COAST DISTRICT
1333 CAMINO DEL RIO SOUTH, SUITE 125
SAN DIEGO, CA 92108-3520
(619) 297-9740
Mr. C. E. Bartley
2489 Ocean St.
Carlsbad, CA 92008
NOTICE OF ACCEPTANCE
Date: August 17, 1989
Applicant: Charles E. Bartley
Document or
Plans: Revised seawall building plans, including approved stairway design
Submitted in compliance with Special Condition(s) No(s).
of Coastal Development Permit No. 6-89-45
Material submitted in compliance with said Special Condition(s) of your
development permit has been reviewed by the District Director and found to
fulfill the requirements of said condition(s). Your submitted material and a
copy of this letter have been made a part of the permanent file.
Sincerely,
Charles Damm
Di-strict Director
By: Paul B. Webb
(1 802 N)
HETHERINGTON ENGINEERING, INC.
GEOTECHNICAL CONSULTANTS
C. E. Bartley August 4, 1989
2489 Ocean Street Proj. No. 249.1
Carlsbad, California 92008
SUBJECr: Revised Foundation Depth
Proposed Seawall
2489 Ocean Street
Carlsbad, California
REFERENCE: "Shore Protection Design Recawnendations,
2489 Ocean Street, Carlsbad, California",
by Hetherington Thgjneerjng, Inc., dated
August 1, 1988.
Dear Chuck:
Based on review of the referenced report and recent observations of exposed bedrock
in the innediate vicinity of the proposed seawall, it appears that a depth of
embedment into bedrock of two feet will be adequate for the proposed wall foundation.
The foundation excavation should be inspected by the geotechnical engineer prior
to the placement of reinforcing steel and if any potentially erodible materials are
present in the seawall foundation excavation which could result in scour, then
deepening of the foundation will be necessary.
Very truly yours,
(both expire 3/31/92)
MKH: cb
5245 AVENIDA ENCINAS 9 SUITE G • CARLSBAD, CALIFORNIA 92008 9 (619) 931-1917
SEPTEMBER 14, 1988 HELEN AND CHARLES BARTLEY
2489 OCEAN ST,CARLSBAD,CA
DEVELOPMENT PROCESSING DIVISION
2075 LAS PALMAS DRIVE, CITY OF CARLSBAD
ATIN :CARTER DARNELL--BLDG DEPT
StJBJECr: IMPROVEMENT OF RETAINING WALL ON BEACH PROPEWIY- "BAR'JLEY SEAWALL"
ATTACHED IS A COPY OF A LIrrK SUBMITTED TO THE GRADING DEPT DESCRIBING THE SUBJECT
WALL FOR WHICH WE DESIRE TO OBTAIN A PERMIT TO BUILD AS SOON AS POSSIBLE TO PRCYTECT
THE PROPERTY BEFORE THE WINTER STORMS COME. WE UNDERSTAND THAT SOME OF THE SUBMITTALS
WE LISTED SHOULD BE SUBMITTED To THE BUILDING DEPT:
TWO SOILS REPORTS
TWO ENGINEER'S DESIGN CALCULATIONS
TWO BLUELINE PRINTS
WE NOW SUBMIT THE ABOVE DIRECTLY To YOU ALONG WITH THE PLAN CHECK FEE OF $70. AN IM-
PORTANT FACT THAT WAS MENTIONED TO JIM MURRAY IS THAT WE ARE AT THE ABOVE ADDRESS
ONLY To ABOUT OCTOBER 5th AND THAT OUR PERMANENT ADDRESS IS AT 6520 E. EXETER BLVD.,
SaYrPSDALE, AZ 85251 TEL (602)946-4558. OUR BROTHER, KEITH HARTLEY, HOWEVER, WILL BE
AT THE CARLSBAD ADDRESS AND CAN TAKE MESSAGES FOR US (TEL 729-6544). IT IS IMPORTANT
TO CONTACT DIRECTLY IF YOU ARE UNABLE TO REACH OUR BROTHER OR PERTINENT ENGINEERS;SO
CALL US COLLECT IN ARIZONA IN ORDER TO MINIMIZE DELAYS. HOPEFULLY, MOST OF THE IN-
FORMATION YOU NEED CAN BE PROVIDED AND THE PERMIT CAN BE ISSUED BEFORE WE LEAVE THE
STATE. IF AT ANY TIME YOU WISH TO CALL THE ENGINEERS AND DON 'T GET TEEN IMMEDIATELY,
PLEASE CALL X7
.
0 EXPEDITE MATTERS BECAUSE I FOUND LIJRING TEE DEVELOPMENT OF TEE
PLANS THEY WY FROM THE PHONES MUCH OF THE TIME.
VERY TRULY YOURS,
9..
SEPTEMBER 14, 1988
DEVELOPMENT PROCESSING SERVICES DIVISION
2075 LAS PALMAS DRIVE
CITY OF CARLSBAD, CA 92009-4859
AT1'N:JIM MURRAY
HELEN AND CHARLES BARTIEI
2489 OCEAN ST., CRLSBAD, CA 92008
SUBJECT: IMPROVEMENT OF RETAINING WALL ON BEACH PROPERTY -"BARI!LE! SPAWALL"
DURING THE JANUARY 1988 STORMSo, THE SEASIDE BANK OF OUR PROPERTY WAS SEVERELY ERODED,
AND IT IS URGENT 10 PROTECT IT FROM FUIVRE DAMAGE. SHORTLY AFTER THE STORMS, WE
ATENFI'ED ¶10 PROCESS A DESIGN WE HAD COMPLETED IN 1983, BUT IT WASN'T ACCEPTABLE
BY YOUR OFFICE DUE TO TECHNICALITIES SUCH AS NON-STANDARD DRAFTING PAPER SIZE.
WE ODNTACTED THE GFfiLOGIST/C[VIL ENGINEER WHO DID THE ORIGINAL WORK TO UPGRADE TO
CARLSBAD 'S PRESENT STANDARDS, BUT, UNFORTUNATELY, HE SAID HE WAS NO LONGER IN THE
BUSINESS. BEING UNABLE TO LOCATE A COMBINATION STRUC1JRAL/GEXYTEO1NICAL RcE,, WE
HIRED SUITABLE SEPARATE TALENTS EARLY IN THE SUMMER, BUT THEIR OTHER COMMITTMENTS
DURING THE JANUARY STORM, OUR ROCK/CENENT BEACH WAIL WAS NOT DAMAGED, BUT IT WAS
NOT HIGH ENOUGH 10 PREVENT APPROXIMATELY SEVEN ir OF ICEPLANT COVERED BANK BEHIND
THE WALL 10 BE WASHED AWAY. WE UNDERSTAND THAT CUR THREE ir HIGH BY 'IWO FEET
THICK WAIL WAS CONSTRUCTED ON BEDROCK SANDSTONE ABCXYI' FIFTY YEARS AOO, AND UNTIL
THE JANUARY 510PM IT HAD ALWAYS BEEN COMPLETELY WVixw WITH SAND DURING OUR
OCCUPANCY SINCE 1967. THE WALL STILL IS WELL BONDED TOGETHER WITH AB(XII' TWO ir
BEING EXPOSED. OUR NEIGHBOR (N THE SOUTH ORIGINALLY BUILT THIS WAIL AND ALSO BUILT
A SIMILAR O11NECTING ONE FOR HIS PROPERTY, EXCEPT THAT HIS WAIL IS FIVE I?r HIGH
AND IS NOT IN LINE BUT ABOUT SEVEN FEET CLOSER 70 THE OCEAN. THE DAMAGE 10 THE
BANK BEHIND HIS WAIL WAS NOT SUBSTANTIAL. THE NEIGHBORS 10 HIS SOUTH WERE ADEQUATELY
PROTECTED BY A STONE REVgTHENI' TEN ir HIGHER THAN OUR WALL AND EXTENDING ABOUT
THIRTY j?r CLOSER '10 THE OCEAN. OUR TWO NEIGHBORS DIRECTLY 10 THE NORTH ALSO HAVE
WAILS ODNSTRUCTED SIMILAR '10 OURS AND OF ABOUT THE SAME AGE, BUT THOSE WAILS ARE
ABCXYP SEVEN imr HIGHER, AND THEIR BANKS SUFFERED NO DAMAGE. OUR THIRD NEIGHBOR
TO THE NORTH HAS A (XNCRETE WAIL TEN FEET HIGHER THAN OURS AND IT HAS EXTENSIVE
DEVELOPMENT INCLUDING A SWIMMING POOL BEHIND IT. THAT PROPERTY SUFFERED NO DAMAGE.
WE PROPOSE TO (INSTRUCT A OONCRE7FE WAIL INTRRAL WITH OUR PRESENT WAIL,I0 THE HEIGHT
OF OUR NEIGHBORING WALLS TO THE NORTH AND '10 REPLACE THE BANK WHICH WAS WASHED AWAY
BEHIND IT. THE PLANS HAVE BEEN CERTIFIED BY LICENSED GEXYI'ECHNICAL AND CIVIL
ENGINEERS AND ARE SUBMITTED HEREWITH WITH WHAT WE SUPPOSE 10 BE THE NECESSARY FORMS,
BLUEPRINTS, AND PERMIT FEES • WE (INSIDER IT URGENT TO OBTAIN PROITION FROM THE
POTENTIAL FORTHCC}IING WINTER STORMS; SO WOULD APPRECIATE YOUR PROMPT ATTENTION TO
PROCESS THE PERMIT. WE UNDERSTAND THAT THE PERMIT IS NECESSARY FROM YOU
WE PROCEED TO OBTAIN AN ADDITIONAL PERMIT FROM THE COASTAL COMMISSION.
VERY TRULY YOURS,
SUBMITTALS: (1) GRADING PERMIT FORM. (2 )THREE BLUELINE PRINTS (3) TWO COPIES OF SOILS
REPORT (4) TWO 'COPIES OF DESIGN CALCULATIONS (5) TWO COPIES OF ESTIMATED GRADING
QUANTITIES (6) CERTIFI(TIONS OF SOILS ENGINEER, DESIGN ENGINEER, AND ONNER (7)
COMPIMM ENVIRONMENTAL IMPACT ASSESSMENT (REF. $175 RECEIPT #81787, DATED 3-10-
88)-(8) $25 GRADING PLAN CHECK FEE ( UNDER 100 cu. yds. . )- (9) PLAN CHECK (BASED
ON A 10' NICE BY 75' LONG WAIL). .
HETHERINGTON ENGINEERING, INC.
GEOTECHNICAL CONSULTANTS
September 23, 1988
Project No. 249.1
C.E. Bartley
2489 Ocean Street
Carlsbad, California 92008
SUBJECT: SEAWALL PLAN REVIEW
2489 Ocean Street
Carlsbad, California
REFERENCE: Shore Protection Design Recommendations, 2489 Ocean
Street, Carlsbad, California, dated August 1, 1988, by
Hetherington Engineering, Inc.
Dear Mr. Bartley:
In accordance with your request we have reviewed the plans dated
September 1, 1988, for a proposed seawall to be constructed at the
subject site. Based on Our review, the plans appear to have been
prepared in accordance with the pertinent geotechnical
recommendations included in the referenced report.
If you have any questions, please call.
Very truly yours,
HETHERINGTO GI EERING, INC.
%OESSIO
!!!m 30488 No. 397 7 rn
5245 AVENIDA ENCINAS • SUITE G 9 CARLSBAD, CALIFORNIA 92008 • (619) 931-1917
,BA RTLEY YE A k/L.L
S pit. RJERV&'r SHORE PROTECTION DESIGN RECOMMENDATIONS
2489 Ocean Street
Carlsbad, California
HETHERINGTON ENGINEERING, INC.
HETHERINGTON ENGINEERING, INC.
GEOTECHNICAL CONSULTANTS
August 1, 1988
Project No. 249.1
C.E. Bartley
2489 Ocean Street
Carlsbad, CA 92008
Subject: SHORE PROTECTION DESIGN RECOMMENDATIONS
2489 Ocean Street
Carlsbad, California
Dear Mr. Bartley:
In accordance with your request, we are providing preliminary
design recommendations for shore protection to be constructed at
the toe of slope at the rear of the subject property. The shore
protection will consist of either a seawall or a stone revetment.
The purpose of the shore protection is to protect the existing
slope against erosion by wave action.
Our work has consisted of review of pertinent coastal design
criteria and geotechnical maps and reports for the site and
vicinity (see References), subsurface exploration, laboratory
testing, engineering analysis and the preparation of this report.
We were provided with a Topographic Map, undated, prepared by
Sidney Hale, which served as the base map for our Plot plan, Figure
1. Elevations used in our analysis were extrapolated from the
Topographic Map using a hand level and should be confirmed by a
future topographic survey.
SITE DESCRIPTION
The site consists of one, residential, rectangularly shaped lot (75
feet x 135 feet) . Site improvements include an attached, wood-
frame, living area and garage structure. Site topography at the
rear of the lot descends to the beach to the southwest at a slope
ratio of approximately 4:1 (horizontal to vertical) . The lower
portion of the slope has been eroded by wave action to near
vertical. Slope vegetation consists generally of ice plant. An
approximately 3 feet high stone seawall was reportedly constructed
along the rear property boundary about 35 years ago. An
approximately 10 feet high stone seawall has been constructed along
the rear boundary of the property to the north and an approximately
5 feet high wall to the south.. The approximate layout of the site
is shown on the attached Plot plan, Figure 1.
5245 AVENIDA ENCINAS • SUITE G • CARLSBAD, CALIFORNIA 92008 9 (619) 931-1917
SHORE PROTECTION DESIGN RECOMMENDATIONS
Project No. 249.1
August 1, 1988
Page 2
GEOTECHNICAL CONDITIONS
Geotechnical conditions were determined by review of Reference 3,
excavation of two test pits at the toe of slope and geologic
mapping of the slope. The approximate locations of the test pits
are shown on the plot plan, Figure 1. The geotechnical conditions
at the site are shown on Cross Section A-A', Figure 2. The Test
Pit Logs are included on Figure 3.
LABORATORY TESTING
Laboratory testing was performed on samples obtained from the test
pits. Laboratory testing consisted of the following:
Dry Density and Moisture Content
(ASTM: D 1188 and ASTM: D 2216)
0 Direct Shear
(ASTM: D 3080)
Material Finer than the No. 200 Sieve
(ASTM: D 1140)
Results of the dry density and moisture content determinations are
shown on the Test Pit Logs, Figure 3. The remaining laboratory
test results are shown on Figure 4.
COASTAL DESIGN CRITERIA
The following coastal design criteria for the subject site are
based on 1983 storm data for the San Diego coastal area (References
2, 4, and 5) and calculations have been performed in accordance
with the Shore Protection Manual (Reference 1)
Still Water Elevation - San Diego Harbor = +8.3 ft. MSL
Scour Elevation - bedrock contact = +2.0 ft. MSL
Design Wave Period = 22 sec.
Elevation of Breaking Wave = +11.5 ft. MSL
Run-up Elevation = +16.0 ft. MSL
HETHERINGTO! ENGINEERING INC.
SHORE PROTECTION DESIGN RECOMMENDATIONS
Project No. 249.1
August 1,, 1988
Page '3
CONCLUSIONS AND RECOMMENDATIONS
General
The construction of a seawall or stone revetment at the toe of
slope to provide protection against slope erosion from wave
action is feasible. Design and construction should take into
account the appropriate geotechnical and coastal features of
the site.
Seawall
A seawall may consist of a cantilever, vertical, retaining wall
founded in the underlying bedrock. The wall should extend to a
crest elevation of +16 feet MSL with some overtopping
expected. The wall should be constructed in line with the
walls to the north and south. Some flanking should be
anticipated if the adjacent walls do not extend to elevation
+16 feet MSL.
Foundations bearing at a minimum depth of 3 feet into bedrock
may be designed for a dead plus live load bearing value of 4000
pounds per square foot. This value may be increased by one-
third for loads due to seismic forces. A lateral bearing value
of 400 pounds per square foot per foot of depth into bedrock
and a coefficient of friction between bedrock and concrete of
0.4 may be assumed. These values assume that foundations will
be poured neat against bedrock. Footing excavations should be
inspected by the Geotechnical Engineer to insure that they are
founded as recommended.
Seawalls should be designed to resist lateral soil pressures
applied above the bedrock contact (approximate elevation +5
feet MSL) of 80 pounds per cubic foot, equivalent fluid
pressure. Walls should also be designed to resist wave forces.
A gravel drain wrapped in filter cloth is recommended directly
behind the face of the wall with weep holes constructed through
the wall face. This is to reduce the hydrostatic pressure
directly behind the wall.
Wall backfill should consist of clean sand or gravel compacted
to at least 90 percent relative compaction (ASTM: D 1557)
Wall backfill should be properly benched into bedrock/terrace
deposits. Wall backfill should be tested and inspected by the
- -. Geotechnical Engineer.
Type V cement should be used for concrete in a marine
environment.
HETHEPINCTON ENGINEERING INC.
SHORE PROTECTION DESIGN RECOMMENDATIONS
Project No. 249.1
August 1, 1988
Page 4
Stone Revetment
A -stone revetment should. be constructed in line with the
adjacent seawalls to the north and south. Prior to
construction of a stone revetment, existing vegetation and
miscellaneous debris should be removed and the existing slope
should be regraded to a 1-1/2:1 (horizontal to vertical) slope
by either placing fill at the toe or by cutting back. Any fill
placed should be properly keyed and benched into
bedrock/terrace deposits and compacted to at least 90 percent
relative compaction.
To prevent scour, the base of the revetmént should be founded
in bedrock requiring excavation of a 3 feet deep key at the toe
of slope which should be approved by the Geotechnical Engineer
prior to the placement of rock. The stone revetment should
extend to a crest elevation of +16 feet MSL with some
overtopping expected. Some flanking should be anticipated if
the adjacent walls do not extend to elevation +16 feet MSL.
Remaining recommendations are shown on the attached Shore
Protection Stone Revetment (Typical Detail) , Figure 5.
Construction of the revetment should be periodically observed
by the Geotechnica]. Engineer.
Review of plans
Plans for the seawall or stone revetment should be reviewed by
the Geotechnical Engineer to confirm conformance with the
recommendations included in this report and to provide
modification as necessary.
If you have any questions, please call.
Very truly yours
HETHERINGTON ,il1XN1 ERING, INC.
'MAI,O. HE,RINGTON
Civi'L inedr 30488
Geotec n cal Engineer 397
(bat expire 3/31/92)
MDH/ss
-' Attachments
cc: 3-Addressee
H
far No. 397
1xp. Dalc.........._ )
%
rr c
HETHERINGTON ENGINE INC.-
REFERENCES
Shore Protection Manual, U.S. Army Coastal Engineering Research Center, 1975.
Coastal Storm Damage, Winter 1983, A Task Force Report, prepared by the U.S. Army Corps of Engineers, Los Angeles District and the.State of California, April 1984.
Retaining Wall Design, 2489 Ocean Street, Carlsbad, California,
by Claude B. Parker, May 5, 1983.
Preliminary Engineering Study, Beach and River Protective
Devices, Del Mar, California, by R.M. Noble & Associates, July
22, 1983..
Coastal Engineering, 1984 Proceeding, Chapter one hundred
eighty-nine, Coastal Design Criteria in Southern California, by
Walker, Nathan, Seymour and Strange
Construction and Geotechnical Methods in Foundation
Engineering, by Robert M. Koerner, 1984.
.
Coastal Flood Plain Development, Orange County Coastline,
prepared by Moffatt & Nichol, Engineers, January 1985.
HETHERINGTON ENGINEERING .
OCEAN STREET
EXISTING I EXISTING
RESIDENCE RESIDENCE
TOP OF
ERODED BANK
EXISTING
SEAWALL
:iuuluiIisIIus
16' HIG
.T.W. ELEV. 91*
I...II.IIIu
TP-1
LEGEND
APPROXIMATE LOCATION
TP-2 OF TEST PIT
A At CROSS SECTION A
If
SCALE: 1"= 20'
PLOT PLAN
KETKERUGTOI LIG IERIiG BARTLEY RESIDENCE
GEOTECHNICAL CONSULTANTS PROJECT NO. 249.1 FIGURE NO. 1
A'
.55E
40
EXISTING
STRUCTURE
30
ERODED AREA OF BAN
20
SLOPEWASH
BEDROCK
MEAN SEA LEVEL 0
-10
CROSS SECTION A - A'
HETHERINGTON ENGINEERING BARTLEY RESIDENCE
GEOTECHNICAL CONSULTANTS PROJECT NO. 249.1 IFIGURE NO. 2
BACKHOE COMPANY: Earthworks BUCKET SIZE: Hand-excavated DATE: 7/5/88 >. Ui .. Ix z c6
I°
TEST PIT NO. i. ELEVATION +6 NSL ZW0ZQ " !z - Ui.-
a a 0
SOIL DESCRIPTION
BEACH SAND: Black and gray silty sand, wet, loose - SIl becomes cobbly @ 1½'
water @ 2'
BEDROCK: Brown-gray silty sandstone, moist, dense,
slightly cemented
15
Total Depth 2½'
110
TEST PIT NO. 2 ELEVATION +9 MSL 0
SLOPEWASH: Brown sand, et, loose
becomes cobbly @ 1½'
bottom of existing wall @ 3'
Brown-red cobbly sand, wet, loose
- BEDROCK: Gray silty sandstone, moist, very dense,
cemented
Total Depth 4½'
LOG OF TESTPITS
KETKERI I'M TOI Ba:ri].ey Residence GEOTECHNICAL CONSULTANTS
PROJECT No. 249.1 FIGURE NO. 3
LABORATORY TEST RESULTS
DIRECT SHEAR
(ASTM: D 3080)
Sample Angle of Internal Cohesion Location Friction ( ) (psf)
TP-2 @ 4' 26 700
MATERIAL FINER THAN THE NO. 200 SIEVE
(ASTM: D 1140)
Sample Passing No. 40 Passing.No. 200
Location Sieve (%) Sieve ()
TP-2 @ 4' 65.9 13.5
Project No. 249.1
Figure No. 4
APPROXIMATE
JGRADE
L30
a A.-20 20-
E
FILTER FABRIC
DEPOSITS 1~7
10-
TERRC
O l
-10
12" TO 16" 5 - 20 # STONE
0 I 1 I I fO 10 20 30 40 50 60
NOTES:
ELEVATION OF BEDROCK CONTACT
WILL VARY WITHIN SITE
FILTER FABRIC SHALL BE PHILLIPS
SUPAC 12NP OR EQUIVALENT
SHORE PROTECTION STONE REVETMENT
(TYPICAL DETAIL)
KETHERINGTON Wt;iRPEG BARTLEY RECIDE.NCE
GEOTECHNICAL CONSULTANTS
PROJECT NO. 249.1 FIGURE NO. 6