Loading...
HomeMy WebLinkAbout2497 OCEAN ST; ; CB111453; Permit07-18-2011 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Applicant: SCOTT PACKARD City of Carlsbad 1635 Faraday Av Carlsbad.CA 92008 Residential Permit Permit No: CBl 11453 Building Inspection Request Line (760) 602-2725 • 4 2497 OCEAN ST CBAD RESDNTL 2030210800 $8,622.00 SubType: RAD Status: ISSUED Lot#: 0 Applied: 06/29/2011 Construction Type: 5B Entered By: RMA Reference*: Plan Approved: 07/18/2011 0 Structure Type: Issued: 07/18/2011 0 Bathrooms: 0 Inspect Area: FRAZIER RES- FINISH OUT 150 SF Orig PC#: CB070099 OF BATHROOIVI & STORAGE ROOM IN BASEMENT Plan Check # PC110026 (PRE-PLUMBED UNDER CB070099) Owner: DONALD FAMILY TRUST 03-19-99 4620 TRIESTE DR CARLSBAD CA 92010 760 822-4925 POBOX 1489 CARLSBADCA 92018 Building Pemiit $108.71 Meter Size Add'l Building Pemiit Fee $0.00 Add'l Reel. Water Con. Fee $0.00 Plan Check $70.66 Meter Fee $0.00 Add'l Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $1.00 PFF (3105540) $0.00 Park In Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $48.00 Renewal Fee $0.00 ELECTRICAL TOTAL $20.00 Add'l Renewal Fee $0.00 MECHANICAL TOTAL $21.50 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Reel. Water Con. Fee $0.00 Additional Fees $0.00 Green Bidg Stands (SBI473) Fee $1.00 Fire Sprinkler Fees $0.00 TOTAL PERMIT FEES $270.87 Total Fees: $270.87 Total Payments To Date: $270.87 Balance Due: $0.00 Inspector: FINAL APP li Date: 3ROVXL Clearance: NOTICE: Please tal<e NO ICE that approval of your project includes tlie "Imposition" of fees, dedications, reseivations, or other exactions hereafter collectively refered to as lees/exactiofts.' Yoli fiave 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth In Government Code Section 66020(a), and file the protest and any other required Information with the City Manager for processing in accordance with CarlstTad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their Imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or sen/Ice fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv othenwise expired. City of Carlsbad BIdg Inspection Request For: 11/16/2011 Permit* CB111453 Title: FRAZIER RES-FINISH OUT 150 SF Inspector Assignment: PY Description: OF BATHROOM & STORAGE ROOM IN BASEMENT (PRE- PLUMBED UNDER CB070099) Type:RESDNTL SubType: RAD Job Address: 2497 OCEAN ST Suite: Lot: 0 Location: APPLICANT SCOTT PACKARD Owner: CARLSBAD TRUST 01-04-11 Remarks: Phone: 7608224925 Inspector: Total Time: Requested By: SCOTT Entered By: CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comments Comments/Notices/Holds Notice ORIGINAL PLANCHECK DONE UNDER PC110026. APPLICANT SEPARATED OUT THIS PERMIT TO PULL EARUER THAN PC110026 Associated PCRs/CVs/SWPPPs Original PC# CB070099 Inspection Historv Date Description 09/29/2011 27 Shower Pan/Roman Tubs 09/06/2011 17 Interior Lath/Drywall 09/06/2011 84 Rough Combo 09/02/2011 17 Interior Lath/Drywall 08/29/2011 84 Rough Combo Act Insp Comments AP PY AP PY AP PY CA PY NEED VENTAUVTION AP PY ^ EsGil Corporation i^rtnersAipwit/i government for ^uiCifiitg Safety S Cj^) /^^^^^3 DATE: 6/24/1^ (6/29/11) y /) ) ^^^^T^^PPUq^NT JURIS. JURISDICTION: Carlsbad n /IA^/^ "' ^ • ^CAFTREVIEWER FILE PLAN CHECK NOT: PCI 10026 /^ SET: I Supplement PROJECTADDRESS: 2497*2499 Ocean St. PROJECT NAME: New Outdoor above Ground Pre-Fab Spa ^ J^^Zwil^y^i^^/ fft^l^^Jl^ I I The plans transmitted herewith have been corrected where necessary and substantially comply ' with the jurisdiction's codes. (^C-£4f) I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 3 The applicant's copy of the check list has been sent to: Scott Packard 4620 Trieste St., Carlsbad, CA 92010 n Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Scott Packard Telephone #: (760) 822-4925 Date contacted: (^f^o/f f (by: k^) Email: spackcon@yahoo.com .Fax #: (760) 730-3238 By: Chuck Mendenhall c/^^o^ iPf^ M ^^^UUT EsGi,C0«n ^ ^ ^^^^^^ ^ \j,0d^ 9320Chesapeake Drive, Suite 208 • SanDiego, Califoraia92123 • (858)560-1468 • Fax(858) 560-1576 y^bad>C110026 //24/11 Please make all connections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2010 California Building Code which adopts the 2009 UPC and the 2008 NEC for regulation of pools and spas. I. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). In addition to signing the plans show on the floor plan for the new bath room In the basemant of 2499 that an exhaust fan wili be provided that complies with CRC Section R303.3 which requires 50 CFM intermittent exhaust. 5. Provide the following notes on the plans that relate to the proposed spa: CBC 3109.4.4.2 Construction permit; safety features required. Commencing January 1, 2007, whenever a buildtng permit is issued for construction of a new swimming pool or spa or any building permit is at a private, single-family home, it shall be equipped with drowning prevention safety features: A. 3109.4.4.3 Enclosure; required characteristics. An enclosure shall have all of the following characteristics: • The pool or spa shall be isolated from access to a home by an enclosure that meets the requirements of Section 3109.4.4.3. • Any access gates through the enclosure open away from the swimming pool and are self- closing with a self-latching device placed no lower than 60 inches above the ground. • A minimum height of 60 inches. • A maximum vertical clearance from the ground to the bottom of the enclosure of 2 inches. • Gaps or voids, if any, do not allow passage of a sphere equal to or greater than 4 inches in diameter. B. Hot tubs or spas with locking safety covers that comply with the American Society for Testing Materials Emergency Performance Specification (ASTM ES 13-89) PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 11-1453 DATE 7/18/11 ADDRESS 2497 Ocean Street RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE POOUSPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING SOLAR PANELS OTHER all internal - bathrooms, storage PLANNER ENGINEE DATE 7-1^-1 J H:\ADIiN\COUNTER/PUNNlNG/ENGlNEEfliNG APPR0VAI5 SEE PC110026 FOR MORE INFO