HomeMy WebLinkAbout2501 El Camino Real; 230; CBC2019-0423; PermitCommercial Permit
Print Date: 12/27/2019
Job Address:
Ccityof
Carlsbad
Permit No: CBC2019-0423
Permit Type:
2501 El Camino Real, 230
BLDG-Commercial
1563023500
Work Class: Tenant Improvement Status: Closed -Finaled
09/04/2019
10/24/2019
Parcel No:
Valuation: $87,531.82
Occupancy Group:
# Dwelling Units:
Bedrooms:
ProjectTitle:
lot#:
Reference #:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Applied:
Issued:
Permit
Finaled:
Inspector: MColl
Final
Inspection: 12/27/2019 1:56:59Pt
Description: GRUBBY$ POKE AND FISH MARKET: 1,882 SF T.I. COFFEE SHOP TO RESTAURANT
Applicant: Owner:
ALLEN GEE R P I CARLSBAD LP
1114 Avenue Of The Americas, Floor 45
New York, NY 10036-7700
214-660-5232 x215232
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
FIRE A-2 & A-3 Occupancies -Tl
FIRE Plan Resub (3rd&Subsequent Submittal/hr)
MANUAL BUILDING PLAN CHECK FEE
MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL
581473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $2,035.72 Total Payments To Date: $2,035.72
Contractor:
JRE CONSTRUCTION INC
1645 S Rancho Santa Fe Rd, Unit 205
San Marcos, CA 92078-5188
760-445-4190
Balance Due: $0.00
$574.34
$402.04
$60.00
$628.00
$136.00
$90.83
$45.00
$71.00
$4.00
$24.51
Please take NOTICE that approval of your project includes the 11lmposition11 of fees, dedications, reservations, or other exactions hereafter
collectively referred to as *'fees/exaction.11 You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
( City of
Carlsbad
Job Address 2501 El Camino Real
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check
Est. Value
mcao1tt-cJIJ.3
PC Deposit -----,-,--r-=---
Dat e a./~ /11
____ APN: 156-302-07 & 156-302-08
Tenant Name: Grubbys Poke and Fish Market CT/Project #: _________ Lot#: ___ _
Occupancy: A-2 Construction Type: 111-B Fire SprinklersB no Air Conditioning:! yes!f no
BRIEF DESCRIPTION OF WORK: Relocate tenant from suite 215 to suuite ~interior tenant improvement
230
D Addition/New: ___________ New SF and Use, ___________ ,New SF and Use,
____ Deck SF, ____ Patio Cover SF (not including flatwork)
~ Tenant Improvement: 1,882 SF, Existing Use Restaurant Proposed use Restaurant
_____ SF, Existing Use ______ Proposed Use ______ _
□ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _
D Solar: ___ KW, __ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No
l.J Plumbing/Mechanical/Electrical Only: _______________________ _
D Other: ----------------------------------
APPLICANT (PRIMARY)
Name: Allen Gee
Address: 790 37th Avenue
City: San Francisco State: CA Zip: 94121
Phone: 415-559-1176
Email: Allen.agarchitects@gmail.com
DESIGN PROFESSIONAL
Name: Allen Gee
Address: 790 37th Avenue
City: San Francisco State: CA Zip: 94121
Phone: 415-559-1176
Email: Allen.agarchitects@gmail.com
Architect State License: ~C~-2~4"'3~0~3 _______ _
PROPERTY OWNER
Name: Brookfield Properties
Address: 6181 South State Street
City: Murry State: Utah Zip: 84107
Phone: 801-463-4232
Email: Jonathan.Kath@brookfieldpropertiesretail.com
CONTRACTOR BUSINESS
Name: :f';i?._~ Cuy,_d-ru cf,'d >J J;',ic_
Address: / 1, '( f S . f2,-,,._ c/4....., sJ._ r,-4f fl 1:-0 s-
City: SJM. lil¼v-<..o.S State: Y"} Zip: ")2,01()'
Phone: Jc,, o · '{ ':I. ,-I I 9 o
Email: TeH--@ 'Jl(_c -b<-t ,' tels , t.. cf1'.'1
State License: <;2-S-C,,(,,\ Bus. License: C'3Lo S I z.y ~,n '(
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)),
1635 Faraday Ave Carlsbad, CA 92008
B-2
Ph: 760-602-2719 Fax: 760-602-8558
Page 1 of2
Email: Building@carlsbadca.gov
Rev. 06/18
( OPTION A): WORKERS'COMPENSATION DECLARATIOl'i.;
I hearby affirm under penalty of perjury one of the following declorotions:
n I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
~ have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the perfpr"]anc&:::work for which this J:)ermit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: S ~ V\A-\0 .:l-vt. ,St, h: o,, h,, £
Polley No. 4i()t'f s'(t. L/z.c!tS Expiration Date: '::I l<;:,lz ., Tl
□ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to ..... --~··· ····-. -·~-.......... ~ R ....... ·-...... -. ~ ... _ ~ -~ ... ~-interest and attorney's fees.
CONTRACTOR SIGNATURE: ~ d7 □AGENT DATE/lJ/z.'f(rj
t,'
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. tf, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
□ I, as owner of the property, am excluslvely contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
□ I am exempt under Section ________ ,Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D Yes □ No
2 I {have/ have not) signed an application for a building permit for the proposed work.
3.1 have contracted with the following person {firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/
contractors' license number):
S. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: LJAGENT DATE: _____ _
CONSTRUCTION LENDING AGENCY. IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code).
Lender's Name: _____________________ Lender's Address: ___________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes ■ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes ■ No
Is the facility to be constructed within 1,000 feet ofthe outer boundary of a school site? □ Yes I No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes, I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABIL1TIES, JUDGMENTS, COSTS AND EXPENSES WH!CH MAY !N ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over S'O' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time
aftec the work;, commenced for a per;od of !Soz:;;.06.4.4 Un;form Md;ng Code).
APPLICANT SIGNATURE: ~ DATE: 8/28/2019
1635 Faraday Ave Carlsbad, CA 92008
8-2
Ph: 760-602-2719 Fax: 760-602-8558
Page 2 of2
Email: Building@carlsbadca.gov
Rev. 06/18
PERMIT INSPECTION HISTORY REPORT (CBC2019-0423)
Permit Type: BLDG-Commercial Application Date: 09/04/2019 Owner: R P I CARLSBAD LP
Work Class: Tenant Improvement Issue Date: 10/24/2019 Subdivision: CARLSBAD TCT#76-18
Status: Closed -Finaled Expiration Date: 06/22/2020 Address:
IVR Number: 21518
Sc';;!~led S~~t~~te Inspection Type Inspection No. Inspection Status Primary Inspector
12/23/2019 12/23/2019 BLDG-Final
Inspection
12/27/2019 12/27/2019 BLDG-Final
Inspection
Checklist Item
BLOG-Building Deficiency
BLDG-Building Deficiency
114720-2019
Checklist Item
BLDG-Building Deficiency
BLDG-Electrical Final
114858-2019
Checklist Item
BLDG-Building Deficiency
BLOG-Electrical Final
BLDG-Fire Final 114864-2019
Checklist Item
FIRE-Building Final
December 27, 2019
COMMENTS
For roof top equipment
Prelim atWest wall only for new lighting
Failed Michael Collins
COMMENTS
Recheck GFCI
Not ready, recheck occupant load number
& accessibility
Passed Paul York
COMMENTS
Recheck GFCI
Not ready, recheck occupant load number
& accessibility
Scheduled Fellx Salcedo
COMMENTS
2501 El Camino Real , 230
Carlsbad, CA 92008-1215
Reinspection Complete ---
Passed
Yes
Yes
Reinspection Complete
Passed
No
No
Complete
Passed
Yes
Yes
Incomplete
Passed
No
Page 2 of 2
PERMIT INSPECTION HISTORY REPORT (CBC2019-0423)
Permit Type: BLDG-Commercial Application Date: 09/04/2019 Owner: R P I CARLSBAD LP
Work Class: Tenant Improvement Issue Date: 10/24/2019 Subdivision: CARLSBAD TCT#76-18
Status: Closed -Finaled Expiration Date: 06/22/2020 Address: 2501 El Camino Real , 230
Carlsbad, CA 92008-1215
IVR Number: 21518
Scheduled Actual .
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
10/29/2019 10/29/2019 BLDG-34 Rough 109033-2019 Partial Pass Michael Collins Relnspectlon Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Prelim atWest wall only for new lighting Yes
11/08/2019 11/08/2019 BL0G-17 Interior 110291-2019 Partial Pass Michael Collins Relnspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wall at Dining Rm. only Yes
BLDG-24 110292-2019 Passed Michael Collins Complete
Rough/Topout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Grease waste & water at Kitchen/prep & Yes
service area
11/12/2019 11/12/2019 BLOG-24 110435-2019 Passed Michael Colllns Complete
Rough/Topout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Underiloor grease waste. Provide grease
waste signage on piping
Yes
11118/2019 11118/2019 BLDG-17 Interior 111109-2019 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wall at Dining Rm. only Yes
BLDG-Building Deficiency Walls at Kitchen/Prep areas Yes
12/09/2019 12/09/2019 BLDG-25 Water 113180-2019 Partial Pass Michael Collins Reinspectlon Incomplete
HeaterNents
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial, in Kitchen/Prep Rm only Yes
12/10/2019 12/10/2019 BLDG-43 Air 113317-2019 Failed Michael Collins Re inspection Complete
Cond./Furnace Set
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready, spoke with Robert about the use
of sleepers on roof.
No
12/16/2019 12/1612019 BLDG-15 113881-2019 Passed Michael Collins Complete
Rool/ReRool (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency HVAC equipment "sleepers" only Yes
12/20/2019 12/20/2019 BLDG-34 Rough 114583-2019 Passed Michael Collins Complete
Electrical
December 27, 2019 Page 1 of 2
DATE: 10/1/2019
JURISDICTION: Carlsbad
PLAN CHECK#.: CBC2019-0423
✓• EsG1I
A SAFEbu:lt Colllpilny
SET: II
PROJECT ADDRESS: 2501 El Camino Real #230
✓APPLICANT
( JURIS.
PROJECT NAME: Grubby's Poke & Fish Market Tenant Improvement
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: q\J Telephone#:
Date contacted: / (b✓-" ) Email:
Mail Telephone
0 REMARKS:
By: Jason Pasiut
EsGil
Fax In Person
Enclosures:
9/26/2019
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 9/11/2019
JURISDICTION: Carlsbad
PLAN CHECK#.: CBC2019-0423
✓• EsG1I
A SAFEbuilt' Company
SET:I
PROJECT ADDRESS: 2501 El Camino Real #230
□ APPLICANT
□ JURIS.
PROJECT NAME: Grubby's Poke & Fish Market Tenant Improvement
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Allen Gee
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Allen Gee Telephone#: 415-559-1176
Date contacted:
Mail Telephone
0 REMARKS:
By: Jason Pasiut
EsGil
(by: ) Email: allen.agarchitects@gmail.com
Fax In Person
Enclosures:
9/6/2019
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBC2019-0423
9/11/2019
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK#.: CBC2019-0423
OCCUPANCY: A-2
TYPE OF CONSTRUCTION: III-B
ALLOWABLE FLOOR AREA: complies
SPRINKLERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 9/4/2019
DATE INITIAL PLAN REVIEW
COMPLETED: 9/11/2019
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
USE: Restaurant
ACTUAL AREA: l,882sf
STORIES: 3
HEIGHT: unchanged
OCCUPANT LOAD: 58
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 9/6/2019
PLAN REVIEWER: Jason Pasiut
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CBC2019-0423
9/11/2019
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring IWQ corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
• PLANS
3. Please taka closer look at sheet A-2.1. The elevation detail call outs reference
the wrong sheet(s) and or details on other sheets.
• MECHANICAL/ ELECTRICAL/ PLUMBING
4. Please define what "FCW' means on sheet P-3.
5. Please show that the water supply connection to the commercial dish washing
machine(s) is protected by an air gap or a back-flow prevention device. CPC
414.2.
6. Please show that the water supply to the urinal(s) is protected by an approved-
type vacuum breaker or other approved backflow prevention device. CPC 603 .5.
7. Please show that potable water outlets with hose attachments, other than water
heater drains, boiler drains, and clothes washer connections, are protected by a
nonremovable hose bib-type backflow preventer, a nonremovable hose bib-type
vacuum breaker, or by an atmospheric vacuum breaker installed not less than 6
inches (152 mm) above the highest point of usage located on the discharge side
of the last valve. CPC 603.5.7.
8. Show that indirect waste pipes that are 5' to 15' long are trapped. (A vent is not
required on the indirect waste pipe). CPC 803.3.
9. Show that indirect waste pipes that are less than 15' in length are provided with a
clean-out. CPC 803.3.
•-*-••'-~--~--__ , -------------..
Carlsbad CBC2019-0423
9/11/2019
10. Please show the water supply to the pure water process system, such as a
reverse osmosis and dialysis water systems, semiconductor washing systems,
and similar process piping systems, protected from backpressure and back-
siphon by a reduced pressure principle backflow preventer. CPC 603.5.18.
11. Hot water recirculating loop systems requirements: Detail the following:
a) The installation of an air release valve on the inlet side of the recirculation
pump, within 4' of the pump.
b) A check valve is required between the recirculating pump and the water
heating equipment to prevent the hot water from flowing backwards
through the recirculation loop.
c) A check valve is required on the cold water supply line between the hot
water system and the next closest tee on the cold water supply line. (See
CPC 608.3 for expansion tank requirements.)
• WALK IN COOLER
12. Provide the manufacturer standard plans and installation instructions/listing
information for the cooler walls and refrigeration equipment being proposed.
CMC 935.
a) Show electrical loads and show that the equipment meets UL 471 and 427.
b) Show connection details for corners and roof including fasteners.
c) Show foam thickness and flame-spread information.
d) Provide a refrigeration ventilation calculation to show adequate cubic foot per
unit horsepower.
13. Show location of indirect drain / floor sink and detail drain pipe size and required
airgap. CPC418.4.
14. Refrigerated Spaces that are less than 3,000 square feet shall meet the
requirements of the Appliance Efficiency Regulations for walk-in coolers or
freezers contained in the Appliance Efficiency Regulations (California Code of
Regulations, Title 20, Sections 1601 through 1608). Note on the plans whether
this installation meets these requirements. CEC 120.6 (a)
15. Please note or show that all electrical penetrations into the cooler shall be sealed
per section 300-7 of the NEC.
16. Please provide a roof plan showing the location of the new condensing unit.
• END OF REVIEW
To speed up the review process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number, calculation
page, etc.
Carlsbad CBC2019-0423
9/11/2019
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate: D Yes D No
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review
items, please contact Jason Pasiut at Esgil. Thank you.
Carlsbad CBC2019-0423
9/11/2019
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Jason Pasiut
PLAN CHECK#.: CBC2019-0423
DATE: 9/11/2019
BUILDING ADDRESS: 2501 El Camino Real #230
BUILDING OCCUPANCY: A-2
BUILDING AREA
PORTION (Sq.Fl)
Tl 1882
Air Con:litioring
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
I 1m use Building Permit Fee illl
I t'Hltill•,
I 19!!7 UBC Plan Check fee llil
t 1\J.m,
...
Valuation
Multiplier
46.51
By Ordinance
Tw,e ofRevt-: P Complete Review
r Repeltive Fee .., I Jill Repeats
,.
Comments:
r Other
r Hourly
EsGDFee ,.
Reg. VALUE
Mod.
r Structural Only
~Hr.@*
($)
87,532
87,632
' J
J
$370.1~
Sheet 1 of 1
OFFICE USE ONLY SAN DIEGO REGIONAL
HAZARDOUS MATERIALS
QUESTIONNAIRE
RECORD ID# I PLAN CHECK# ________________ _
BP DATE
Business Name 1 , .-:-. Business Contact Telephone#
12€ c,r,.~fy,,..c.n/Y\ h,.c.. :1-di ~;,,,._p 1e,o -t<t, <(19a
ProjectAdgr-ess lA _ r, 1, City fJ State Zj,> Code 4 2-)0/ '2LLvvv<-(h)_r_t.<:A.<.I' 1"' 210 Cvv-h·\c,t" CA '1Z-_il_Oo
APN#
Mailing Address {) _ 1 /I I r ,<;ity 1,, • State Zip Cod'lc, /~'/\ s, fUM--~~t-e_e( :l=t'l.O._--faVv<NW5u.\:. 1UJ7~ ------
Plan File#
Project Cqqtact , fl Al)plicant E-mail Telephone# J-e H-6-o-c ;:Je-J< :r-df @ ~ ~ 111 tb , ' '°"1. --, e, o ti 'i •'fl '+Y.. -------------------
The following questions represent the f3cllity's activitieS,NOT the specific project description.
PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San
Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled,
applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: Facility's Square Footage (including proposed project):
1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives
2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These.
4. Flammable Solids 8. Unstable Reactives 12. Radioactives
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISION !HMO): If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123.
Call (858) 505-6700 prior to the issuance of a building permit.
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy:
1. D Is your business listed on the reverse side of this form? (check all that apply).
YES i (for new construction or remodeling projects)
2. D Will your business dispose of Hazardous Substances or Medical Waste in any amount?
3. D Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500
4.
5.
6.
7_
8.
pounds and/or 200 cubic feet?
D "1. Will your business store or handle carcinogens/reproductive toxins in any quantity? D ~ Will your business use an existing or install an underground storage tank?
D I Will your business store or handle Regulated Substances (CalARP)?
D Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?
D Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to
or greater than 1.!320 gallons? (California's Aboveground Petroleum Storage Act).
□ CalARP Exempt
L
Date Initials
0 CalARP Required
L
Date Initials
□ CalARP Complete
L
Date Initials
PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCDl: Any YES• answer requires a stamp from APCD 10124 Old Grove Road, San
Diego, CA 92131 apcdcomp@sdcoµnty.ca.gov (858) 586-2650). [*No stamp required if 01 Yes and 03 Yes and 04-06 No}. The following questions are intended
to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive
requirements contact APCD. Residences are typically exempt, except -those with more than one building+ on the property; single buildings with more than four
dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [+Excludes garages & small outbuildings.]
1. D Will the project disturb 160 square feet or more of eXisting building materials? YES i
2. D Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition.
3. D O (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been pelformed by a Certified Asbestos Consultant or Site Surveillance
Technician?
4. D D (ANSWER ONLY IF QUESTION 3 15 YES) Based on the survey results, will the project disturb any asbestos containing material? Notification
may be required 10 working days prior to commencing asbestos removal.
5. 0 t:ii, Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet
(www.sdapcd.org/jnfolfacts/permits.pd:0 for typical equipment requiring an APCD permit.
6. D D (ANSWER ONLY IF QUESTION 5 15 YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bounda
Briefly de.,§f_ribe proposed project: T _,\,. -fo-. \Les-+-~
I declare u re best of my knowledge and belief tHe responses made herein are true and correct. /o/Z..l('f/'i
Name of Signature of Owner or Authorized Agent Date
FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ________________________________ _
BY DATE: __ / . L
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMO• APCO COUNTY-HMO APCO COUNTY-HMO APCO
*A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply.
HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division
LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO
DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION
Check all that apply:
AUTOMOTIVE
D Battery Manufacturing/Recycling
0 Boat Yard
0 Car Wash
D Dealership Maintenance/Painting
0 Machine Shop
O Painting
O Radiator Shop
0 Rental Yard Equipment
D Repair/Preventive Maintenance
O Spray Booth
D Transportation Services
O Wrecking/Recycling
CHEMICAL HANDLING
D Agricultural supplier/distributor
D Chemical Manufacturer
D Chemical Supplier/Distributor
O Coatings/Adhesive
D Compressed Gas Supplier/Distributor
O Dry Cleaning D Fiberglass/Resin Application
0 Gas Station
D Industrial Laundry
0 Laboratory
D Laboratory Supplier/Distributor
0 Oil and Fuel Bulk Supply
D Pesticide Operator/Distributor
CHEMICAL HANDLING
D Photographic Processing
D Pool Supplies/Maintenance
D Printing/Blue Printing
0 Road Coatings
D Swimming Pool
D Toxic Gas Handler
D Toxic Gas Manufacturer
METAL WORKING
D Anodizing
0 Chemical Milling/Etching
D Finish-Coating/Painting
0 Flame Spraying
0 Foundry
0 Machine Shop-Drilling/Lathes/Mills
0 Metal Plating
0 Metal Prepping/Chemical Coating
D Precious Metal Recovery
D Sand Blasting/Grinding
D Steel Fabricator
D Wrought Iron Manufacturing
AEROSPACE
D Aerospace Industry
D Aircraft Maintenance
D Aircraft Manufacturing
OTHERS AND MISCELLANEOUS
0 Asphalt Plant
D Biotechnology/Research
D Chiropractic Office
D Co-Generation Plant
0 Dental Clinic/Office
D Dialysis Center
D Emergency Generator
D Frozen Food Processing Facility
D Hazardous Waste Hauler
D Hospital/Convalescent Home
D Laboratory/Biological Lab
0 Medical Clinic/Office
D Nitrous Oxide (NOx) Control System
D Pharmaceuticals
0 Public Utilny
D Refrigeration System
0 Rock Quarry
D Ship Repair/Construction
D Telecommunications Cell Site
D Veterinary Clinic/Hospital
D Wood/Furniture Manufacturing/Refinishing
ELECTRONICS
0 Electronic Assembly/Sub-Assembly
D Electronic Components Manufacturing
D Printed Circuit Board Manufacturing
NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES.
ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE
HAZARDOUS MATERIALS DIVISION (HMD) REVIEW OF BUSINESS PLANS. FDR MORE INFORMATION CALL (858) 505-6880.
LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES
Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District.
CHEMICAL
47 -Organic Gas Sterilizers
32 -Acid Chemical Milling
33 -Can & Coil Manufacturing
44 -Evaporators, Dryers & Stills Processing
Organic Materials
24 -Dry Chemical Mixing & Detergent Spray
Towers
35 -Bulk Dry Chemicals Storage
55 -Chrome Electroplating Tanks
COATINGS & ORGANIC SOLVENTS
27 -Coating & Painting
37 -Plasma Arc & Ceramic Deposition Spray
Booths
38 -Paint, Stain & Ink Mfg
27 -Printing
27 -Polyester Resin/Fiberglass Operations
METALS
18 -Metal Melting Devices
19 -Oil Quenching & Salt Baths
32 -Hot Dip Galvanizing
39 -Precious Metals Refining
ORGANIC COMPOUND MARKETING
!GASOLINE. ETC)
25 -Gasoline & Alcohol Bulk Plants & Terminals
25 -Intermediate Refuelers
26 -Gasoline & Alcohol Fuel Dispensing
COMBUSTION
34 -Piston Internal -Combustion Engines
13 -Boilers & Heaters (1 million BTU/hr or larger)
14 -Incinerators & Crematories
15 -Burn Out Ovens
16 -Core Ovens
20 -Gas Turbines, and Turbine Test Cells & Stands
48 -Landfill and/or Digester Gas Flares
ELECTRONICS
29 -Automated Soldering
42 -Electronic Component Mfg
FOOD
12 -Fish Canneries
12 -Smoke Houses
50 -Coffee Roasters
35 -Bulk Flour & Powered Sugar Storage
SOLVENT USE
28 -Vapor & Cold Degreasing
30 -Solvent & Extract Driers
31 -Dry Cleaning
ROCK AND MINERAL
04 -Hot Asphalt Batch Plants
05 -Rock Drills
06 -Screening Operations
07 -Sand Rock & Aggregate Plants
08 -Concrete Batch, CTB, Concrete Mixers, Mixers
&Silos
10 -Brick Manufacturing
OTHER
01 -Abrasive Blasting Equipment
03 -Asphalt Roofing Kettles & Tankers
46 -Reverse Osmosis Membrane Mfg
51 -Aqueous Waste Neutralization
11 -Tire Buffers
17 -Brake Debonders
23 -Bulk Grain & Dry Chemical Transfer & Storage
45 -Rubber Mixers
21 -Waste Disposal & Reclamation Units
36 -Grinding Booths & Rooms
40 -Asphalt Pavement Heaters
43 -Ceramic Slip Casting
41 -Perlite Processing
40-Cooling Towers-Registration Only
91 -Fumigation Operations
56 -WWTP (1 million gal/day or larger) & Pump
Station
NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION
CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600.
HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division
,,
ELISE ROTHSCHILD
Director
Qtountp of $)an iJBiego
DEPARTMENT OF ENVIRONMENTAL HEALTH
FOOD AND HOUSING DIVISION
P.O. BOX 120261, SAN DIEGO, CA 92112-9281
Phone: (858) 505-6658 FAX: (8.58} 505-6824
1(800)2=
www sdcdeh org
REC
OCT .2 5 2019
CITY OF CARLSBAD
BUIL01NG DiVISION
AMY HARBERT
Assistant Director
OBA: GRUBBYS POKE AND FISH MARKET DATE: 9/25/2019
JOB
ADDRESS:
250 I EL CAMINO REAL
CARLSBAD
PLAN CHECK#: DEH2019-FFPP-011579
SUBMITTED
BY:
ALLEN GEE BUILDING USE: New Food Facility
Plans are approved contingent upon the following
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
Department of Environmental Health IDEID stamped plans shall be maintained at the jobsite and available for review at the time of the
inspection.
Changes to equipment layout, menu, or application must be submitted for approval. Changes made without approval will make the plan approval
null and void.
Obtain local Building Department and all applicable agencies permits and approvals PRIOR TO FINAL INSPECTION AND APPROVAL
TO OPERA TE BY TIDS DEPARTMENT .
All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI accredited testing agency.
Upon completion of 50%-80% of construction, email jeff.arsua@sdcounty.ca.gov to schedule inspection. In lieu of a plumbing inspection by
DEH, ensure that the plumbing is constructed to these standards:
a. Floor sinks shall be installed ½ exposed and equipped with an appropriate grill cover if no access is provided for cleaning.
b. Drain lines shall slope¼" per foot, shall not exceed 15' in length and shall terminate a minimum of I" above the floor sink with a legal air
gap or otherwise approved by the enforcing agency. Drain lines shall not intersect walkways or door ways.
c. No condensate drainage of any kind can drain to the mop sink.
d. 3-compartment sinks, preparation sinks, dump sinks, and any other plumbed equipment must drain indirect to a floor sink.
e. Grease traps/interceptors, if required by the local waste water authority must be located outside of the food preparation, food storage, or
warewashing areas.
f Floor surfaces must be sloped I :50 to required floor drains.
g. Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed in a chase
so as to facilitate cleaning.
Owners and/or operators must pass an approved and accredited Food Safety Certification course. Proof of successful completion of this course is
to be furnished at the final inspection .
All equipment is to be in place and functional. At the time when the final inspection is requested, the facility shall have all utilities operational
and all refrigeration shall have an ambient air temperature of 38"F or below and shall be equipped with a thermometer accurate to+/-2"F in the
warmest section of the unit.
Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashes, around pipes and conduits with silicone sealant.
AN AIR BALANCE REPORT IS REQUIRED IF THE FACILITY BAS VENTILATION HtfODS.urr,.,nn· t
ANY FOOD PROCESSING AREAS M ST BE COMPLETELY ENCLOSED. OPE . E BLE WALL
PANEL ARA E ROLL-UP DOORS OR OTHER MEANS OF RENDERING F OT FULLY
. ENCLOSED ARE NOT APPROVED.
Be advised. applicable jurisdiction requirements that result in changes to approved planG may OQUire qylslon9 tt thl Department of
. Environmental Health plans.
Plans reviewed by:
~A~
Jeff Arsua, REUS, CPO
"Environmental and public health through leadership, partnership and science"
'
* -2 -September 25, 2019
PLEASE EMAIL JEFF.ARSUA@SDCOUNTY.CA.GOV OR TEXT/CALL 858-247-6013 AT LEAST 10
WORKING DAYS IN ADVANCE TO SCHEDULE INSPECTIONS. A FINAL INSPECTION MUST BE
CONDUCTED AND AN ENVIRONMENT AL HEALTH PERMIT SHALL BE ISSUED PRIOR TO OPENING
AND OPERATING TIDS FOOD ESTABLISHMENT.
{ City of
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
8-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2 719
www.carlsbadca.gov
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance
requ irements apply to their projects. Unless none of the requirements apply, the completed checklist must be
included in the building permit application. It may be necessary to supplement the completed checklist with
supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance
requirements. For example, projects that propose or require a performance approach to comply with energy-
related measures will need to attach to this checklist separate calcu lations and documentation as specified by
the ordinances.
A If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required
by ordinance, an explanation must be provided to the satisfaction of the Building Official.
A Details on CAP ordinance requirements are available on the city's website.
Project Name/Building
Permit No.:
Appllcatlon Information
Grubbys Poke and Fish Market BP No.: Cl?)C/J.0 lq -OLJJ.j
Property Address/APN: 2501 El Camino Rea l Suite #2030, Carlsbad, CA 92008/ 156-302-07 & 156-302-08
Applicant Name/Co.: Allen Gee/ AGArchitect s
Applicant Address: 790 37th Avenue, San Francisco, CA 94121
Contact Phone: 415-559-1176 Contact Email:
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
B-50
Contact Phone:
Contact Email:
Applicant Signature: ~ --~---
Page 1 of 3
Allen.agarchitects@gmail.com
Date: 8/28/2019
Revised 04/19
City of Carlsbad Climate Action Plan Consistency Checklist
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project.
For residential alterations and additions to existing buildings, contact the building counter for the building permit valuation.
Building Permit Valuation (BPV) $ _8_7'-,5_3_1_.8_2 _______ _
Construction Type I Complete Section(,) I Notes:
D Residential
D New construction 1A
D Alterations: D exempt
D BPV ~ $60,000
D Electrical service panel upgrade
1A
1A
1-2 family dwellings and townhouses with attached garages
only
D BPV ~ $200,000 1A
Multi-family dwellings only where interior finishes are removed
and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
■ Nonresidential
D New construction 1 Band 2
■ Alterations 2
1. Electric Vehicle Char.9.!!!g
A. D Residential New construction and major alterations (or electric panel upgrade)*
Please refer to Carlsbad Ordinance CS-349 when completing this section.
D One and two-family residential dwelling or townhouse with attached garage:
D One EVSE ready parking space required D Exception :
D Multi-family residential· D Exception ·
Total Parking Spaces EVSE Spaces
Proposed Capable I Readv I
I I
Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number)
EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number)
EVSE other= Total EVSE spaces -EVSE Installed
(EVSE other may be "Capable," "Ready" or "Installed.")
Installed I Total
I
*Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation~ $60,000 or
include an electrical service panel upgrade; (2) for multifami~ dwellings (three units or more without attached garages), alterations have a building permit valuation
~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed.
B. D Nonresidential new construction (includes hotels/motels) D Exception ·
Total Parking Spaces EVSE Soaces
Proposed Capable I Ready I Installed I Total
I l I
Calculation: Refer to the table below
Total Number of Parkino Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces
D 0-9 1 1
D 10-25 2 1
□ 26-50 4 2
D 51-75 6 3
□ 76-100 9 5
D 101-150 12 6
D 151-200 17 9
D 201 and over 10 percent of total 50 percent of Reouired EV Spaces
Updated 4/12/2019 2
City of Carlsbad Climate Action Plan Consistency Checklist
2. 0 Transportation Demand Management (TOM)
A. List each proposed nonresidential use and gross floor area (GFA) allocated to each use.
B. Employee ADT/1,000 square feet is selected from the table below.
Use GFA Employee ADT for first Employee ADT for each
1,000 S.F. subsequent 1,000 S.F.
Restaurant 1,882 11 10
Total
If total employee ADT is greater than or equal to 110 employee ADT, a TOM plan is required.
TOM plan required: Yes D No ■
Updated 4/12/20 I 9
Employee ADT Estimation for Various Commercial Uses
' -. -
Office ( all)2 20
Restaurant 11
Retaib 8
Industrial 4
Manufacturing 4
Vvc!r_eh9_usina 4
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 101hEdition
20
11
4.5
3.5
3
1
2 For all office uses, use SANDAG rate of 20 ADT/1 ,000 sf to
calculate employee ADT
3 Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
Sample calculations:
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf = 8 ADT
2. 9,334 sf -1,000 sf = 8,334 sf
3. (8,334 sf / 1,000 x 4.5) + 8 = 46 Employee ADT
Total Employee ADT
21
21
3