NONRESIDENTIAL GREEN
BUILDING CODE STANDARDS
MANDATORY MEASURES
CERTIFICATION CHECKLIST
B-52
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Tliiiform, signed and completed, and all receipts fir recycled materials shlI bi
submitted to the Building Inspector prior to Final lnspectionJ
Site Development Mandatory
5.106.1 Storm water pollution prevention plan. For projects of one acre or less, develop a Storm
Water Pollution Prevention Plan (SWPPP) that has been designed specific to its site, conforming to (x)
the State Storm water NPDES Construction Permit or local ordinance, whichever is stricter, as is
required for projects over one acre. The plan should cover prevention of soil loss by storm water
run-off and/or wind erosion, of sedimentation and/or of dust/particulate matter air pollution.
5.106.4 Bicycle parking and changing .rooms. Comply with Sections 5.106.4.1 and 5.106.4.2; or (x)
meet local ordinance, whichever is stricter.
5.106.4.1 Short-Term bicycle parking. If the project is expected to generate visitor traffic, provide
permanently anchored bicycle racks within 200 feet of the visitor's entrance, readily visible to (x)
passers-by, for 5 percent of visitor motorized vehicle parking capacity, with a minimum of one two-
bike capacity rack.
5.106.4.2 Long Term bicycle parking. For buildings with over 10 tenant-occupants, provide secure
bicycle parking for 5 percent of tenant-occupied motorized vehicle parking capacity, with a minimum (x)
of one space. - -
5.106.5.2 Designated parking. Provide designated parking for any combination of low emitting,
fuel-efficient and carpool/van pool vehicles as shown in Table 5.106.5.3.1. (x)
5.106.8 Light pollution reduction. Comply with lighting power requirements in the California
Energy Code and design interior lighting such that zero direct-beam illumination leaves the building (X)
site. Meet or exceed exterior light levels and uniformity ratios for lighting zones 1-4 as defined in
Chapter 10 of the California Administrative Code, using the following strategies:
Shield all exterior luminaries or use cutoff luminaries (X)
Contain interior lighting within each source (x)
Allow no more than .01 horizontal foot candle 15ft. beyond the site (X)
Contain all exterior lighting within property boundaries (x)
Exception: See part 2, Chapter 12, Section 1205.6 for campus lighting requiremerfts fOr parking
facilities and walkways.
5.106.10 Grading and paving. The site shall be planned and developed to keep surface water
away from buildings. Construction plans shall indicate how site grading or drainage system will (X)
manage all surface water flows.
Water Efficiency and Conservation
Indoor Water Use
5.303.1 Meters. Separate meters shall be installed for the uses described in Sections 503. 1.1 (X)
through 503.1.3.
5303.1.1 Buildings in excess of 50,000 square feet. Separate sub-meters shall be installed as
follows:
For each individual leased, rented, or other tenant space within the building projected to (X)
consume
more than 100 gal/day.
For spaces used for laundry or cleaners, restaurant or food service, medical or dental office,
laboratory or beauty salon or barber shop projected to consume more than 100 gal/day.
B-52 Page 1of 5 Rev. 5/17
5.303.1.2 Excess consumption. Any building within a project or space within a building that is
projected to consume more than 1,000 gal/day. (X)
5.303 Percent savings. A schedule of plumbing fixtures and fixture fittings that will reduce the
overall use of potable water within the building by 20 percent shall be provided (Calculate (X)
savings by Water Use Worksheets or utilize Table 5.303.2.3).
5.303.2.1 Multiple showerheads serving one shower. When single shower fixtures are
served by more than one showerhead, the combined flow rate of all the showerheads shall not (x)
exceed the maximum flow rates specified in the 20 percent reduction column contained in
Table 5.303.2.3 or the shower shall be designed to allow only one showerhead to be in
operation at a time.
5303.6 Plumbing fixtures and fittings. Plumbing fixtures (water closets
and urinals) and fittings (faucets and showerheads) shall comply with the requirements listed As applicable
for each type in items listed in Table 5.303.6.
Water closets (toilets) - flushometer type (X)
Water closets (toilets) - tank type (X)
Urinals (x)
Public lavatory faucets (x)
Public metering self-closing faucets (x)
Residential bathroom lavatory sink faucets (x)
Residential bathroom lavatory sinks (X)
Residential showerheads (X)
Single shower fixtures served by more than one showerhead (x)
Outdoor Water Use
5.304.1 Water Budget. A water budget shall be developed for landscaping irrigation use. (x)
5.304.2 Outdoor potable water use. For new water service, separate meters or submeters
shall be installed for indoor and outdoor potable water use for landscaped areas between
1,000 and 5,000 square feet. (X)
5.304.3 Irrigation design. In new nonresidential projects with between 1,000 and 2,500
square feet of landscaped area (the level at which the MLO applies), install irrigation controllers
and sensors which include the following criteria and meet manufacturer's recommendations.
5.304.1.1 Irrigation controllers. Automatic irrigation system controllers installed at the time of
final inspection shall comply with the following:
Controllers shall be weather- or soil moisture-based controllers that automatically adjust
irrigation in response to changes in plant's needs as weather conditions change. (x)
Weather based controllers without integral rain sensors or communication systems that As applicable account for local rainfall shall have separate wired or wireless rain sensors which connects or (x) communicates with the controller(s). Soil moisture-based controllers are not required to have
rain sensor input.
Construction Waste Management Plan
(x)
5.408.1 Construction waste diversion. Establish a construction waste management plan or
meet local ordinance, whichever is more stringent. (x) 5.408.2 Construction waste management plan. Submit plan per this section to enforcement
authority within the city.
5.408.1.4 Documentation. Provide documentation of the waste management plan (see form (x)
B-59) that meets the requirements listed in Section 5.408.1.1 thru 5.408.1.3 and the plan is
accessible to the enforcement authority.
5.408.3 Construction waste. Recycle and/or salvage for reuse a minimum of 50 percent of
nonhazardous construction and demolition debris or meet local ordinance, whichever is more
stringent. (x) Exceptions:
Excavated soil and land-clearing debris
Alternate waste reduction methods, developed by working with local agencies if
diversion or recycle facilities capable of compliance with this item do not exist.
5.408.3 Excavated soil and land clearing debris. 100 percent of trees. Stumps, rocks and
B-52 -I Page 2 of 5 Rev. 5/17
associated vegetation and soils resulting primarily from land clearing shall be reused or
Building Maintenance and Operation
5.410.1 Recycling by occupants. Provide readily accessible areas that serve the entire
building and are identified for the depositing, storage and collection of nonhazardous materials (x)
for recycling.
5.410.2 Commissioning. For new buildings 10,000 square feet and over, building (x)
commissioning for all building systems covered by T24, Part 6, process systems and
renewable energy systems shall be included in the design and construction processes of the
building project. Commissioning requirements shall include items listed in Section 5.410.2. -
5.410.2.6 (x)
5.410.2.1 Owner's Project Requirements (OPR). Documented before the design phase of
the project begins the OPR shall include items listed in Section 5.410.4. (x)
5.410.2.2 Basis of Design (BOD). A written explanation of how the design of the building
systems meets the OPR shall be completed at the design phase of the building project and
updated periodically to cover the systems listed in Section 5.410.2.2. (x)
5.410.2.3 Commissioning plan. A commissioning plan describing how the project will be
commissioned shall be started during the design phase of the building project and shall include
items listed in Section 5.410.2.3. (X)
5.410.2.4 Functional performance testing shall demonstrate the correct installation and
operation of each component, system and system-to-system interface in accordance with the (x)
approved plans and specifications.
5.410.2.5 Documentation and training. A Systems manual and systems operations training
are required. , (X)
5.410.2.5.1 Systems manual. The systems manual shall be delivered to the building owner or
representative and facilities operator and shall include the items listed in Section 5.410.2.5.1. (x)
5.410.2.5.2 Systems operations training. The training of the appropriate maintenance staff
for each equipment type and/or system shall include items listed in Section 5.410.2.5.2. (x)
5.410.2.6 Commissioning report. A complete report of commissioning process activities
undertaken through the design, construction and reporting recommendations for post
construction phases of the building project shall be completed and provided to the owner or
representative.
5.410.4 Testing and adjusting. Testing and adjusting of systems shall be required for (X)
buildings less
than 10,000 square feet.
5.410.4.2 Systems. Develop a written plan of procedures for testing and adjusting systems. (x)
Systems to be included for testing and adjusting shall include, as applicable to the project, the
systems listed in Section 5.410.3.2. (x)
5.410.4.3 Procedures. Perform testing and adjusting procedures in accordance with industry
best practices and applicable national standards on each system. (X)
5.410.4.3 HVAC balancing. Before a new space-conditioned system serving a building or
space is operated for normal use, the system should be balanced in accordance with the
procedures defined by national standards listed in Section 5.410.3.3.1. (X)
5.410.4.4 Reporting. After completion of testing, adjusting and balancing, provide a final report (X)
of testing signed by the individual responsible for performing those services.
maintenance instructions and copies of guaranties/warranties for each system prior to final
inspection.
5.410.4.5 Operation and maintenance manual. Provide the building owner with detailed
operating and maintenance manual
5.410.4.5.1 Inspection and reports. Include a copy of all inspection verifications and reports
required by the enforcing agency.
B-52 Page 3 of 5 Rev. 5/17
Environmental Quality
Fireplaces
5.503.1 Install only a direct-vent sealed-combustion gas or sealed wood-burning fireplace or a (x)
sealed woodstove and refer to residential requirements in the California Energy Code, Title 24,
Part 6, Subchapter 7, Section 150. As Applicable
5.503.1.1 Woodstoves. Woodstoves shall comply with US EPA Phase II emission limits. (X)
Weather Resistance and Moisture Management
5.407.1 Weather protection. Provide a weather-resistant exterior wall and foundation envelope
as required by California Building Code Section 1403.2 and California Energy Code Section 150, (x)
manufacturer's installation instruction instructions or local ordinance, whichever is more stringent.
5.407.2 Moisture control. Employ moisture control measured by the following methods:
5.407.2.1 Sprinklers. Prevent irrigation spray on structures. (X)
5.407.2.2 Entries and openings. Design exterior entries and openings to prevent water intrusion (X)
into buildings.
Pollution Control
5.504.3 Covering of duct openings and protection of mechanical equipment during
construction. At the time of rough installation or during storage on the construction site and until
final start up of the heating and cooling equipment, all duct and other related air distribution (x)
component openings shall be covered with tape, plastic, sheet metal or other methods to reduce
the debris or duct which the _amount _of _may _collect _in_ _system.
5.504.5.3 Filters. In mechanically ventilated buildings, provide regularly occupied areas of the
building with outside and return air prior to occupancy that provides at least a MERV of 8.
5.504.4 Finish material pollutant control. Finish materials shall comply with Sections 5.504.4.1
through 5.504.4.6
5.504.4.1 Adhesives, sealants, caulks. Adhesives and sealants used on the project shall meet
the requirements of the following standards: (x)
Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and
caulks shall comply with local or regional air pollution control or air quality management
district rules where applicable or SCAQMD Rule 1168 VOC limits as shown in Tables
5.504.4.1 and 5.504.4.2.
Aerosol adhesives and smaller unit sizes of adhesives and sealant or caulking
compounds (in units of product, less packaging, which do not weigh more than one pound
and do not consist of more than 16 fluid ounces) shall comply with statewide VOC
standards and other requirements, including prohibitions on use of certain toxic
compounds, of California Code of Regulations, Title 17, commencing with Section 94507.
5.504.4.3 Paint and coatings. Architectural paints and coatings shall comply with Table 5.504.4.3
5.504.4.3.1 Aerosol paints and coatings. Aerosol paints and coatings shall meet the Product-
Weighted MIR limits for ROC in Section 94522 (a)(3) and other requirements, including prohibition
on use of certain toxic compounds and ozone depleting substances (CCR, Title 17, Section 94520
etseq.).
5.504.4 Carpet systems. All carpet installed in the building interior shall meet the testing and
product requirements of one of the standards listed in Section 5.504.4.4.
50504.4.4.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the
requirements of the Carpet and Rug Institute Green Label Program.
5.504.4.4.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 804.4.1.
5.504.4.5 Composite wood products. Hardwood, plywood, particleboard and medium density
fiberboard composite wood products used on the interior or exterior of the building shall meet the
requirements for formaldehyde as specified in Table 5.504.4.
5.504.4.5.2 Documentation. Verification of compliance with this section shall be provided as
requested by the enforcing agency. Documentation shall include at least one of the following:
Product certification and specifications
Chain of custody certifications
Other methods acceptable to the enforcing agency
5.504.4.6 Resilient flooring systems. Comply with the VOC emission limits defined in the 2009 (X)
CHPS criteria and listed on its Low-emitting Materials List (or product registry) or certified under
the _FloorScore_ program _of the _Resilient _Floor _Covering _Institute.
B-52 Page 4 of 5 Rev. 5/17
Indoor Moisture and Radon Control
5.505.1 Indoor moisture control. Buildings shall meet or exceed the provisions of the California
Building Code, Title 24 Part 2, Sections 1203 (Ventilation) Chapter 14.1. (X)
Air quality and Exhaust
5.506.1 Outside air delivery. For mechanically or naturally ventilated spaces in buildings, meet the (X)
minimum requirements of Section 121 of the California Energy Code, CCR, Title 24, Part 6 and
Chapter 4 of CCR, Title 8 or the applicable local code, whichever is more stringent.
5.506.2 CaThon DIOXIDE (CO2) monitoring. For buildings equipped with demand control ventilation,
CO2 sensors and ventilation controls shall be specified and installed in accordance with the (X)
requirements of the latest edition of the California Energy Code, Title 24, Part 6, Section 120.1.(C) (4)..
Outdoor Air Quality
5.508.1 Ozone depletion and global warming reductions. Installations of HVAC, refrigeration and
fire suppression equipment shall comply with Sections 5.508.1.1 and 5.508.1.2. As
5.508.1 CFCs. Install HVAC and refrigeration equipment that does not contain CFCs. applicable
5.508.1.2 Halons. Install fire suppression equipment that does not contain Halons. (X)
(x)
I, as the professional responsible for this project, certify that, to the best of my knowledge, the mandatory items
listed on this form have been incorporated into the project in order to comply with Title 24, Part 11 of the 2016
California Green Building Standards. All receipts for recycled materials .have been attached to this form.
Project Address: 2502- E ( C4rn t 0 1 Plan Check Number:LARC2,019.6211
Print Name: 1/i/I Signed: (35L
License Number: 9 &/ 1 9 Date: iii i 9
B-52 Page 5 of 5 Rev. 5/17
412-243-7925 22:26:48 11-11-2019 1/9
GENERAL CONTRACTOR:
DISCOUNT WASTE
2502 EL CAMINO REAL
VMS
CARLSBAD CA 92008
WASTE MANAGEMENT Construction & Recycling Services
5701 S. Eastern Ave., STE 300, Commerce, CA 90040
714-480-2317 (Direct) 866-459.3985 (Fax)
DUMPSITE/LANDFILL C&D SORT & TRANSFER FACILITY Acct: 350-73526
Palomar Landfill (PAL) EDCO CDI Recycling & Buy Back Center Sales Rep: Margaret Miramontes
5960 El Camino Real 2245 Las Posas Rd cscoIttdiscountwaste.com
Carlsbad, CA, 92008 San Marcos, CA. 92078 Prepared Date: 10/25/2019
DATE OF SERVICE SVC TICKET IS BIN SIZE MATERIAL TYPE
Total
Tons
Tons
RCY
RECY
RATE % FACILITY
7/23/2019 108419 40YD TRASH / MSW 1.30 0.00 0.00% PALOMAR LANDFILL (PAL)
8/7/2019 112882 40Y0 MIXED DEMO 6.35 S.S9 88.00% EDCO SAN MARCOS (EDO)
9/5/2019 122447 4DYD TRASH / MSW 3.2S 0.00 0.00% PALOMAR LANDFILL (PAL)
9/23/2019 127570 4DYD TRASH / MSW 4.76 0.00 0.00% PALOMAR LANDFILL (PAL)
10/1/2019 130100 4DYD TRASH / MSW 4.09 0.00 0.00% PALOMAR LANDFILL (PAL)
10/1/2019 130111 40YD TRASH / MSW 2.00 0.00 0.00% PALOMAR LANDFILL (PAL)
10/7/2019 132165 40YD TRASH / MSW 1.25 0.00 0.00% PALOMAR LANDFILL (PAL)
10/16/2019 134714 40YD TRASH / MSW 0.07 0.00 0.00% PALOMAR LANDFILL (PAL)
Total Tons 23.07
Total Tons Diverted 5.59
Total Tons Landfilled 17.48
124.22% Total Diversion I
412-243-7925 22:28:26 11-11-2019 8/9
8:03 AN Roll. Off Dispatch Closed Ticket Display 11/12/2019
Opened by HEERMUD].
350-73526 DISCOUNT WASTE Closed by LEELTRAN
2502 EL CANINO REAL CARLSBAD CA 92008-1201
Ticket 132165 Driver code 1CMOR Requested by NATE 404 242 5993
Dumpinfo:Site PAL T Tkt 195XXXX Qty 1.25 Tax
Load type E/R Equipment code - Points 0
Statue Code * Additional comments exist for this ticket *
Date Time Time
Dispatched: 10/07/2019 14:34 Arrived at customer: 14:47
Loaded / Drop off: 14:54 StOp Ticket:
Restart Ticket: Arrived at landfill: 15:14
Finished at landfill: 15:24 Ticket completed: 15:45
Waste
Eve Quantity Special Description Job # Type Tax T/P
DTN 1.25 NSW T.
400 1.00 MEW T
Bottom
P3=cit P11=Viev Dates P12=Prev P13Additiona1 Comments F17=Top F18aBottom
72 0=Profile
412-243-7925 22:28:39 11-11-2019 9/9
8:03 AM Roll Off Dispatch Closed Ticket Display 11/12/2019
Opened by UEERMUD1
350-73526 DISCOUNT WASTE Closed by LBELITRPIN
2502 EL CANINO REAL CARLSBAD CA 92008-1201
Ticket 134714 Driver code LICAR Requested by TYLER 678 722 8828
Dumpinfo:Site PAL T Tkt 451XXXX Qty .07 Tax
Load type E/R Equipment code - Points 0
Status Code a Additional comments exist for this ticket •
Date Time Time
Dispatched: 10/16/2019 11:36 Arrived at customer: 11:49
Loaded [Drop off: 11:57 Stop Ticket:
Restart Ticket: Arrived at landfill: 12:11
Finished at landfill: 12:47 Ticket completed: 13:04
Waste
Svc Quantity Special Description Job * Type Tax T/P
DTN .07 T
40D 1.00 706371 706371 NSW T
Bottom
P3Exit P13.View Dates P12Prev F13Additional Coenta Pl7Top 71820ttom
P20=Prof Lie
412-243-7925 22:27:14 11-11-2019 2/9
8:03• AM Roll OZ Dispatch Closed Ticket Display 11/3.2/2019
Opened by EMONTELL
350-73526 DISCOUNT WASTE Closed by TLOVELR1
2502 EL CAMINO REAL CARLSBAD CA 92008-1201
Ticket 108419 Driver code KJCAR Requested by CUST
Dwnpinfo:Site PAL T Tkt 771XXXX Qty 1.30 Tax
Load type Sf0 Equipment code - Points 0
Status Code * Additional comments exist for this ticket *
Date Time Time
Dispatched: 7/23/2019 10:07 Arrived at customer: 10:09
Loaded / Drop off: 10:10 Stop Ticket:
Restart Ticket: Arrived at landfill: 10:12
Finished at landfill: 10:15 Ticket completed: 10:15
Waste
Svc Quantity Special Description Job U Type Tax T/P
DTN 1.30 NSW T
400 1.00 MSW T
Bottom
P3=Exit F11View Dates F22Prev F13Additiena1 Comments F17=Top F18Botton
F20aProf Lie
412-243-7925 22:27:26 11-11-2019 3/9
EDCO WASTE & RECYCLING SERVICES, INC
24 S. LAS POSAS RD
SAN NARCOS, CA 978
(760) 744-270
Customer: l(7l4 Ticket: 1466 In: 8:59
Date: 00107/19 Out; 9:00
COAST WASTE/I INA LOUELRCE
560 EL CAPIIND REAL
CARLSBAD CA 9008
Commodity Units
45 C & D NIX 6.5 per- TON
CGross(n): 46,540. lbs Man Wt Tare 33,80. lbs Scilti
INVOICE
Truck: 6089/0000
Container:
Route: 08645
Origin; 086 CARLSBAD
Extended
Charge
Net: 12,70. 1bs3
TOTAL DUE
Construction & Demolition Diversion Certificate - Diversion Percentage 88%
This cirUfies that the conpany listed above has utilized an DICO facility to divert construction deeelltiia IatUial5 in accordance
with LEED roqutreaent. The diversion tonnage I; booed on an overall tonnage percentage of the re: ve EiXl facility.
RODRIGO
1AI / ~'L
ff
I
412-243-7925 22:27:39 11-11-2019 4/9
8:03 AM Roll. Off Dispatch Closed Ticket Display 11/12/2019
Opened by cHERRER4 350-73526 DISCOUNT WASTE Closed by LBELTRAS 2502 EL CASINO REAL CARLSEAD CA 92008-1201
Ticket 122447 Driver code KITCAR Requested by DREW EMAIL flumpinfo:Site PAL T Tkt 455]OCXX Qty 3.25 Tax Load type 5/0 Equipment code - Points 0 Status Code * Additional comments exist for this ticket *
Date Time Time Dispatched: 9/05/2019 7:23 Arrived at customer: 7:30 Loaded I Drop off: 7:37 Stop Ticket: Restart Ticket: Arrived at landfill: 7:59 Finished at landfill: 8:27 Ticket completed: 8:27
Waste Bye Quantity Special Description Job # Type Tax TIP DTN 3.25 142W T 400 3.00 P0* 688521 142W T
Bottom
F3"Exit F11=View Dates P12ruPrev ?l3uAdditional Comments F17=Top F18=20ttom
120 c5Profi1e
412-243-7925 22:27:50 11-11-2019 5/9
8:03 AM Roll Off Dispatch Closed Ticket Display 11112/2019
350-73526 DISCOUNT WASTE
Opened by OCS Driver
Closed by LBELTRAN
2502 EL CANXNO REAL CARLSBAD CA 92008-1201
Ticket 127570 Driver code ICJ'CAR Requested by CHRIS 678 722 8796
Dumpinfo:Site PAL T Tkt 099]000C Qty 4.76 Tax
Load type FYS Equipment code - Points 0
Status Code * Additional comments exist for this ticket *
Date Time Time
Dispatched: 9/23/2019 5:55 Arrived at customer:
Loaded / Drop off: Stop Ticket:
Restart Ticket: Arrived at landfill: 6:00
Finished at landfill: 6:10 Ticket completed: 6:10
Waste
Ova Quantity Special Description Job It Type Tax T/P
DTN 4.76 MOW T
400 1.00 s/o TKT 127397 NSW T
Bottom
F3-Exit F11=View Dates F12=Prev F13Additional Coento P17-Top F18Bottom
F20=profile
412-243-7925 22:28:03 11-11-2019 6/9
8:03 AM Roll Off Dispatch Closed Ticket Display 1112/2019
Opened by HDERNUD1 350-73526 DISCOUNT WASTE Closed by LDEL'IRMI
2502 EL CANINO NEAL CARLSBAD CA 92008-1201
Ticket 130100 Driver code KMORD Requested by CHRIS 404 242 5993
Dumpinfo:Site PAL T Tkt 058XXXX Qty 4.09 Tax Load type 5/0 Equipment code - Points 0
Status Code * Additional comments exist for this ticket *
Date Time. Time
Dispatched: 10/01/2019 7:25 Arrived at customer: 7:32
Loaded I Drop off: 7:39 Stop Ticket:
Restart Ticket: Arrived at landfill: 8:02
Finished at landfill: 8:43 Ticket completed: 8:46
Waste
Svc Quantity. Special Description Job # Type Tax TI'? DTN 4.09 P18W T
400 1.00 P18W T
Bottom
73aEx1t F11View Dates P12Prev F13=Additional Co'"ts P17=Tep F18=Bottom
720=Profi2e
412-243-7925 22:28:15 11-11-2019 7/9
8:03 AN Roll. Of Dispatch Closed Ticket Display 11/12/2019
Opened by HBBRZ4UD1
350-73526 DISCOUNT WASTE Closed by LBELTRAN
2502 EL CAXINO REAL CARLSBAD CA 92008-1201
Ticket 130111 Driver code RMORD Requested by CHRIS
Dumpinfo:Site PAL T Tkt 131XaCX Qty 2.00 Tax
Load type DNR Equipment code - Points 0
Status Code * Additional comments exist for this ticket *
Date Time Time
Dispatched: 10/01/2019 8:47 Arrived at customer: 8:49
Loaded / Drop off: 8:50 Stop Ticket:
Restart Ticket: - Arrived at landfill: 9:44
Finished at landfill: 9:53 Ticket completed: 9:56
Waste
Sire Quantity special Description Job * Type Tax T/P
DTN 2.00 T
40D 1.00 NSW T
Bottom
F3R3cit PilView Dates P12'Prev F13AddLtioxia1 Comments F17=Top F18Bottam
2 0=Profile
LI