Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2502 GATEWAY RD; ; CB081773; Permit
01-07-2011 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB081773 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2502 GATEWAY RD CBAD COMMIND Sub Type: 2132610100 Lot#: $7,086,744.00 Construction Type: Reference #: VIASAT- 3 STORY SHELL TILT-UP BLDG=77,4000 SF (BUILDING 8) COMM 0 3B Applicant: SMITH CONSULTING STE 200 12220 EL CAMINO REAL SAN DIEGO CA 92130 858-793-4777 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: Owner: PIVOTAL 650 CALIFORNIA ST L L C C/O PACIFIC CO 1702 E HIGHLAND AVE #310 PHOENIX AZ 85016 EXPIRED 09/16/2008 KG Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD#3Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedited Plan Review $16,124.04 Meter Size $0.00 Add'l Reel. Water Con. Fee $10,480.63 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $1,488.22 PFF (3105540) $30,960.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees ?? HMP Fee ?? TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $30,826.60 $0.00 $0.00 $0.00 $0.00 $0.00 $30,480.12 $0.00 $0.00 $0.00 $120,359.61 Total Fees:$120,359.61 Total Payments To Date:$10,480.63 Balance Due:$109,878.98 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. City of Carlsbad /f*2^ 1635 Faraday Ave., Carlsbad, CA 92008 B ^|*f^ 760-602-2717/2718/2719 O^fLfP Fax: 760-602-8558 X^T<^ Building Permit Application JOB ADDRESS -v^-^y-* -v /O-Lj Y/ ) CT/PROJECT# LOT#(I PH*E# # OF UNITS # BEDROOMS kUV07600 Plan Check NoPB^ I ' O @ Est. Value£ ^ 0 % , 7W */ r7 Plan Ck. Deposit /O *jffl' &3 Datetf~/L*~OS~ 44 SUITE#/SPACE#/UNIT# APN^, ^, i ^f _ _. # BATHROOMS TENANfl" BUSINESS N*ME j^// (^ CONSTR. TYPE OCC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) ff fJug- i/£u| "77/icgg -Syo/?y 3?ii£i-L. O^jt-y ^W-D/A^ &F "Tit-f-uf (-(^jjyrRv(c^f/d^, EXISTING USE PROPOSED USE GARAGE (SF) CONTACT NAME (If Different Font Applicant) ADDRESS CITY STATE ZIP PHONE FAX EMAIL PROPERTY OWNER NAME - ADDRESS . ' CITY ' STATE 1 ZIP . fH-o&Jft. kk $e3&l*> PHONE FAX^^-f *,.,*, a -i^l- (>c}3-Li'2-Ol 15I-VW- 1/02. EMAIL 1 ARCH/DESIGNER NAME & ADDRESS" \ (/ STATE LIC. # PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS YES| |#. N0| | YES^JNOQ] YES| | N0| | APPLICANT NAME _-- S ' i , 5 ^y^A-ntt CotiSm-TtAft. Apc4/fe*7£ ~ Ifa3> t?l£6EMTJrALgrZ, ADDRESS ' ' CITY STATE ' ZIP PHONE ' FAX EMAIL , , CONTRACTOR BUS. NAME ADDRESS CITY STATE ZIP PHONE FAX EMAIL STATE UC.# CLASS CITY BUS. LIC.# (Sec. 7031.5 Business and Profession^ Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). WORKERS' COMPENSATION Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declaratbn 1 1 1 have and will maintain a certificate of consent to self-insure for workers' compensation as provided b 1 1 1 have and will maintain workers' compensation as required by Section 3700 of the Labor Code, for the number are: Insurance Co PC Thjs section need not be completed if the permit is for one hundred dollars ($1 00) or less. I | Certificate of Exemption : I certify that in the performance of the work for which this permit is issued, I sh; California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subjec addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, intere &£ CONTRACTOR SIGNATURE ', y Section 3700 of the Labor Code, for the performance of the work for which this permit is issued, performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy licv No. Expiration Date II not employ any person in any manner so as to become subject to the Workers' Compensation Laws of ,t an employer to criminal penalties and civil fines up to one hundred thousand dollars (&1 00,000), in st and attorney's fees. DATE OWNER-BUILDER DECLARATION / hereby affirm that 1 am exempt from Contractor's License Law for the following reason: | | 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). | | 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). | | 1 am exempt under Section Business and Professions Code for this reason: 1 . 1 personally plan to provide the major labor and materials for construction of the proposed property improvement. I |Yes I JNo 2. 1 (have / have not) signed an application for a building permit for the proposed work. 3. 1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4. 1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5. 1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): >£f PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR N O N - R E S 1 O E N Tl A L B U I L D I N G PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? | |Yes I iNo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or ainjuality management district? I lYes I I No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I JYes I IN IF ANY OF THE ANSWERS ARE YES,/ EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATIONS >£f APPLICANT'S SIGNATURE DATE ijcu lui a JJDIIVJU ui luii u«y 1/It/If* 6.4.4 Uniform Building Code). ngArch t August 26, 2009 Will Foss Mike Peterson City of Carlsbad 1635 Faraday Avenue Carlsbad, GA 92008 SUBJECT: Request for Plan Review Application Extension Shell Building for ViaSat - Bressi Ranch Lots 10-13 CB 081773 - 2502 Gateway Road Gentlemen: Due to unfavorable economic conditions in the commercial real estate market, this project was placed on hold last fait. The original plan review application will expire 9/15/09. To date we have received plan check corrections from ail departments and agencies, and generated responses to about 90% of them, but we have not re-submitted revised drawings for approval. The project owner, Pivotal 650 California LLC, has advised us that conditions appear favorable for a Spring 2010 start-up. Therefore, we intend to keep this application active, and ask that you.authorize a 6-month extension to expire on 3/15/10. As justification for the extension, know that the building was designed in accordance with the 2007 edition CBC and related ICC codes, which will remain in effect through the proposed extension. We took forward to your response. Please do not hesitate to call us should you have questions. Sincerely^ f , 5eter J. Bussett A Vice President iln p^T -J K:\07Fiies\07123:301 Bressi Ranch Lots iQ-13\Admin\Permil Prbcessing\Builciing\PC EXln Req 082609.doc UZ2O El Camino Real Suite 200 San Diego, CA 92130 858-793.4777 858-793.4787 ^x August 26, 2009 Will Foss Mike Peterson City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 SUBJECT: Request for Plan Review Application Extension Shell Building for ViaSat - Bressi Ranch Lots 10-13 CB 081773 - 2502 Gateway Road Gentlemen: Due to unfavorable economic conditions in the commercial real estate market, this project was placed on hold last fall. The original plan review application will expire 9/15/09. To date we have received plan check corrections from all departments and agencies, and generated responses to about 90% of them, but we have not re-submitted revised drawings for approval. The project owner, Pivotal 650 California LLG, has advised us that conditions appear favorable for a Spring 2010 start-up. Therefore, we intend to keep this application active, and ask that you authorize a 6-month extensionjo expire on 3/15/10. As justification for the extension, know that the building i accordance with the 2007 edition CBC and related ICC codes, which will remain in 'effect through the proposed extension. look forward to your response. Please do not hesitate to call us should you have questions 'incerely, eter J. BussettA jce President K:\07Fihs\Q7123 S01 Bressi Ranch Lois W-13\Admin\Permit Processing\Buildmg\PC EXln Req 082609.doc U22O El Camino Real Suite 200 San Diego, CA 91130 8S8-793.477? 858-79347S7 Fax City of Carlsbad JULY 2, 2009 SMITH CONSULTING ARCHITECTS TAD SIEGENTHALER STE 200 12220 EL CAMINO REAL SAN DIEGO CA 92130 RE: APPLICATION DATE: 09/16/2008 PLAN CHECK*: CB081773 ADDRESS; . 2502 GATEWAY RD EXPIRATION DATE: 09/15/2009 PERMIT TYPE: COMM/IND DESCRIPTION: 77,400 SF TILT UP SHELL BLDG,.... You applied to have your plans checked on the date noted above. To date, the related building permit has not been obtained. The original plan review application will expire as no building permit has been issued. Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed. The provisions of sections 304 (d) of the Uniform Building Code state: "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee." In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department. 'roject Abandoned -1 will pick up the plans within 10 days 'roject Abandoned - Plans may be destroyed you have any questions, please contact the Building Department at (760) 602-2719. Building Department CC: PIVOTAL 650 CALIFORNIA, LLC 1635 Faraday Avenue•* Carlsbad, CA 92008-7314 • (760) 602-270O - FAX (760} 602-8560 City of Carlsbad Building Department JULY 2, 2009 SMITH CONSULTING ARCHITECTS TAD SIEGENTHALER STE200 12220 EL CAMINO REAL SAN DIEGO CA 92130 RE: APPLICATION DATE: 09/16/2008 PLAN CHECK #: CB081773 ADDRESS: 2502 GATEWAY RD EXPIRATION DATE: 09/15/2009 PERMIT TYPE: COMM/IND DESCRIPTION: 77,400 SF TILT UP SHELL BLDG,.... You applied to have your plans checked on the date noted above. To date, the related building permit has not been obtained. The original plan review application will expire as no building permit has been issued. Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed. The provisions of sections 304 (d) of the Uniform Building Code state: "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee." In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department. Project Abandoned -1 will pick up the plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions, please contact the Building Department at (760) 602-2719. Building Department CC: PIVOTAL 650 CALIFORNIA, LLC 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-27OO • FAX (76O) 602-8560 EsGil Corporation In Partnership with government for Quitting Safety DATE: SEPT. 29, 2OO8 Q APPLICANT <^"tT JURIST) JURISDICTION: CARLSBAD ITTCANREVIEWER Q FILE PLAN CHECK NO.: 08-1773 SET: I PROJECT ADDRESS: 2502 GATEWAY ROAD PROJECT NAME: VIASAT (BUILDING # 8) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: SMITH CONSULTING ARCHITECTS 12220 EL CAMINO REAL, # 200, CA 92130 Esgil Corporation staff did not advise the applicant that the plan check has been completed. il Corporation staff did advise the applicant that the plan check has been completed. Person contacted: SMITH CONSULTING Telephone #: 858-793-4777 Datecoptacted:/0///C?J(by>^z^ Fax #: 858-793-4787 Maiy Telephone Fax/ In Person REMARKS: By: ALI SADRE Enclosures: Esgil Corporation D GA [X] MB E] EJ D PC 9/18 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 CARLSBAD OS-1773 SEPT. 29, 20O8 GENERAL PLAN CORRECTION LIST JURISDICTION: CARLSBAD PLAN CHECK NO.: O8-1773 PROJECT ADDRESS: 2502 GATEWAY ROAD Type of Construction = lll-B/Spr.; Story = Three; Occupancy = B/F-1; Actual Area: Total 1st Floor Area = 25,800; 2nd Floor Area = 25,800; 3rd Floor = 25,800; Total = 77,400; allowable area = 12,000x 3 (Stories) X 1.69 (Yards) = 60,840 (no good) (Allowable areas for F-1 is used as the most restrictive occup. for non-separated uses); Height = 52' DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 7/3 SEPT. 29, 20O8 REVIEWED BY: ALI SADRE FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. >• • The following note should be given with each correction list: Please-make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to. the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. CARLSBAD 08-1773 SEPT. 29, 2008 NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? G Yes G No 1. Please revise the notes on Sheet TS1 to clarify second floor that is noted twice. The last line should say third floor. 2. Using F-1 occupancy as the primary use so the non-separated uses are implemented for this project, renders max. 2 stories of F-1 occupancy, sprinklers can be used for one additional story, however, they can not be used for allowable area increases. Justify actual versus allowable areas for this project. 3. Justify the non-rated three story F occupancy building. F is not permitted on the on the 3rd floor in a non-rated building. Sprinklers can by used for additional story or allowable area increases not both, clarify! See the next two items for the city policies related to this item. See Table 503. 4. Automatic sprinklers are required for buildings having an aggregate floor area of 5,000 sq. ft. or more. City ordinance. See the next item as well. 5. If sprinklers are required by city ordinance (i.e., >10,000 square feet), then they can't be used in lieu of one-hour construction, additional story, etc. (city policy). • FIRE-RESISTIVE CONSTRUCTION 6. Provicte-details on the plans for the fire-resistive construction. Include roof/ceiling assemblies, floor/ceiling assemblies, wall assemblies, column and beam assemblies, etc. Be sure to list with each detail the basis of approval (U.L. listing number, ICC research report, etc.). This applies to all the rated assemblies. 7. Detail how fire-resistive wall construction will be maintained at built-in wall fixtures and behind mailboxes, fire extinguisher cabinets, electric panels exceeding 16 square inches in area, etc. Section 712.3.2. 8. Detail on the plans how fire-resistive wall and ceiling protection will be maintained at all duct penetrations, such as at fans and vents. Section 716. 9. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor- ceilings and roof-ceilings shall be protected as required in IBC Section 712." CARLSBAD O8-1773 SEPT. 29, 20O8 10. Fire dampers shall be installed per Section 716.5 at all duct and air transfer openings of: a) Ceilings of fire-resistive floor-ceiling assemblies or roof-ceiling assemblies. b) Fire barriers, (occupancy separations) (see exception for walls). c) Fire partitions at fire-rated corridors; Shaft enclosures. 11. Smoke dampers shall be installed per Section 716.5 at all duct and air transfer openings of: a) Fire-rated corridors; Shaft enclosures. 12. If smoke dampers are required, the plans shall show the locations of the smoke detectors listed in the options of Section 716.3.2.1 of the IBC. 13. Clearly identify location and hourly fire-resistive rating of vertical shafts on the plans. Provide construction details showing location of fire dampers and how fire resistivity will be maintained at floors and roofs. Section 707. 14. Where columns require a fire-resistance rating, the entire column, including its connections to beams or girders, shall be protected. Where the column extends through a ceiling, fire resistance of the column shall be continuous from the top of the floor through the ceiling space to the top of the column. Section 714.2.2. 15. Incidental use areas may need to be separated from the main occupancy. See Table 508.2 below. Please address the following specific concerns: a) Even if sprinklers are used to eliminate the need for 1-hour wall construction, Section 508.2.2.1 still requires the partitions to extend to the underside of the floor/roof above and for any doors in the partitions to be self-closing. ROOM OR AREA Storage rooms over 100 square feet SEPARATION AND/OR PROTECTION 1 hour or provide automatic fire-extinguishing system — • STAIRWAYS 16. Stairways should be enclosed as specified in Section 1020: a) One-hour fire-resistive barrier walls are required in this project unless an exception is cited for each case justifying lesser rating. b) Doors should be labeled 1-hr, fire assemblies for 1-hr, stair enclosures. Sec. 715. Also such doors should have a maximum transmitted temperature end point of not more than 450°(F) above ambient at end of 30 minutes of standard fire test exposure. Sec. 715.3.4. c) Penetrations into or through an exit enclosure are prohibited, except for equipment and ducts necessary for independent pressurization, sprinkler piping, standpipes and electrical conduit serving the enclosure. d) Exit enclosures should include an exit passageway on the ground floor extending to the exterior. Section 1024. Only exit doors are permitted to open into the exit passageway. Section 1021.4. Additionally, a fire-rated door is required between the exit enclosure & the exit passageway (having a 1-hr, rating). Sec. 1020.1.1. CARLSBAD OS-1773 SEPT. 29, 2OO8 CORRIDORS 17. Show the applicable exceptions on the floor plans, otherwise, indicate one hour rated corridors on plans. Alternatively, indicate they will be under a separate permit. Section 1017.1. If not applicable, skip to the next section. 18. Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes. Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 715.4.7. Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 715. 19. Windows in the walls of fire-rated interior corridor walls (Section 715.5): a) Such openings shall be protected by fixed glazing listed and labeled for a fire-protection rating of at least %-hr. (or %" thick wired glass in steel frames). b) The maximum width or height of such windows shall not exceed 54", and the maximum area may not exceed 1,296 sq in. c) The total area of such windows shall not exceed 25% of area of a common wall with a rm. 20. Duct penetrations (or air transfer openings) of fire-rated corridor construction shall have smoke dampers per Sections 716. 21. Provide a complete architectural section of the corridor, showing all fire-resistive materials and details of construction for the fire partition walls and roof/ceilings and all penetrations. Sec. A106.1.1. See Sec. 708.4. Provide a legend for rated corridors on plans. • ELEVATORS 22. Per IBC, Section 707.14: "Elevator hoistway enclosures shall be constructed in accordance with Sec. 707.4 & Ch. 30." Per IBC, Sec. 707.4: Shaft enclosures including exit enclosures shall be 1-hr, rated. IBC, Table 601. See next item. 23. Per IBC, Section 707.7: Openings in a shaft enclosure shall be protected in accordance with Section 714 as required for fire barriers. Such openings shall be self-closing or automatic-closing by smoke detection. IBG, Table 714.2 requires min opening protection assembly of 1-hr, for one-hour fire rated shafts. 24. Doors other than the hoistway door and the elevator car door are prohibited at the point of access to elevator car, except doors readily openable from the car side without a key, tool, special knowledge or effort. IBC, Section 3002.6. This applies to the ground floor if the corridor is one hour rated. Otherwise, note the exception cited on plans. • MISCELLANEOUS ITEMS 25. Please show "No Parking" signage in the loading zone area, on detail 5/AS3. CARLSBAD OS-1773 SEPT. 29, 2008 26. The reference to detail 5/A8.1 as noted on Sheets A2 & A3 are incorrect for the elevator shafts. 27. Please complete the blank bubbles on plans, i.e., See A4 (4-locations), etc. 28. Where is detail 13/A7.1, as referenced on A2, gridline A? 29. Please note where details 5, 10 & 15/A7.1 are referenced on plans. • STRUCTURAL 30. Please submit a copy of the project soils report to the city or EsGil for review. 31. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans. 32. Specify size, ICC approval number and manufacturer of power driven pins, expansion anchors or epoxy anchors. Show edge, end distance and spacing. Section A106.1.1. 33. On the foundation plans for the mechanical enclosure on Sheet S-2, please indicate XT/1 as noted near gridline B. 34. Clarify detail 24 as referenced on detail 24/SD-5, clarify! 35. On detail 2/SD-2, the 3/16" x 3"x continuous plate, looks like it is only 24" or so, in length, please clarify! 36. Please note where detail 3/SD1 is referenced on plans. 37. Please specify where detail 5/SD-3 is referenced on plans. 38. Please_remove the "Not For Construction" Stamp on Structural Plans. 39. Please observe that the revised plans need to be stamped and signed by the project engineer. 40. On the wall panel elevations E-4 & E-5, please justify 6" o.c. tie spacing. This applies to the column like elements (24" wide) with aspect ratios less than 2.5:1. ACI, Sec. 21.4.4.2. The required spacfng is 1/4(dsmaiiescoi. dim.) = %" x13-3// < 3.3". 41. Redundancy Factor SDC D - FI a) In the lateral calculations, seismic forces must be increased by a factor of 1.3 to account for redundancy (Seismic Design Categories D through F), per ASCE 7-05, Section 12.3.4.2, and equation 12.4-3. CARLSBAD 08-1773 SEPT. 29, 2008 • ADDITIONAL 42. Please see attached for the P/M/E correction items. 43. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE at Esgil Corporation. Thank you. CARLSBAD 08-1773 SEPT. 29, 2008 PLUMBING and MECHANICAL CORRECTIONS PLAN REVIEWER: Eric Jensen PLUMBING (2006 UNIFORM PLUMBING CODE) 1. Correct the total CFH adjacent to the gas meter on sheet P0.1. Gas pipe sizing is adequate. 2. Hot water supplied to a public use lavatory or any bathtub is limited to a maximum temperature potential of 120 degrees. Detail how this temperature limitation is achieved. (I see the mixing valve, but no mention or hint of what it is for). 3. If the office building has public areas, drinking fountains must be provided. Please respond. Table 4-1. 4. A minimum of one drinking fountain is required at each occupied floor in schools, theaters, auditoriums, dormitories, offices, or public buildings. UPC Table 4-1, footnote 13. 5. Identify the extent of the private sewer, water, and gas systems on the plumbing site plan. Clearly specify, on the plans, which City Department is responsible for the permitting, plan check, and inspections for the private utility systems. If private, the responsibility of the City Building Department, and under the Uniform Plumbing Code, provide complete civil site utility plans for plan check, or obtain a separate permit from the City for the civil site plans. 6. Please show the upstream sewer manhole rim and finished floor elevations. Provide backwater valves for all fixtures'installed on floor levels below the next upstream manhole rim elevation. (Only fixtures installed on floor levels below the next upstream manhole rim elevation may flow through a backwater valve.) UPC 710.1. 7. Provide a plumbing material schedule on the plans describing the following systems: Potable water piping, the drain, waste, and vent piping, gas piping, and the roof drains. Note: Possible future return air plenum, check with the architect. • Plumbing materials installed in a duct or plenum may not have a flame spread index of more than 25 and a smoke-developed index of more than 50. Provide both indexes for the piping reference in the plumbing specifications for installation above the ceiling. UPC 701.1.2. CARLSBAD 08-1773 SEPT. 29, 2008 8. All water supply systems that have quick closing valves installed therein (washing machines, flush valve fixtures, etc.) shall have devices installed to control the effects of water hammer. Please detail. UPC 609.10. MECHANICAL (2006 UNIFORM MECHANICAL CODE) 9. An elevator machinery room is required to be separated from the remainder of the building by fire barriers (706) and horizontal assemblies (711). Please detail how these ratings will be maintained for the mechanical openings shown. The transfer air duct for the elevator machinery room is missing damper protection. Please provide. IBC 3006.4. 10. Provide smoke detection in the supply air duct of an "air-moving system" for required shut-off of equipment for smoke control. UMC Section 609.0 During the Tl phase undoubtedly the heat pumps installed under this shell phase will require shut-down protection. • An "air-moving system" is a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space. UMC Section 203.0. 11. On the mechanical plans clearly show the limits of ceiling space used as duct or plenum. Then address the following on the plans: • Specify that all combustible materials exposed within the plenum space must comply with UMC Section 602.2. Flame-spread index of not more than 25 and a smoke-developed rating of not more than 50. • A combustion products vent, vent connector, chimney, or chimney connector shall not extend into or through an air duct or plenum. UMC Section 804.0. • Environmental and/or product-conveying duct systems shall not extend into or through ducts or plenums. UMC Sections 504.1 (Environment) & 505.1 (Product conveying). • Add the following three specifications to the mechanical and electrical plans: "Electrical wiring methods to be installed in the plenum areas shall comply with NEC 300-22(c)1", "Nonmetallic pneumatic tubing must be listed and labeled for use in plenum areas", and "Recessed speaker enclosures and light fixtures shall be listed and labeled for use in plenum locations". UMC 602.2. 12. Detail the primary and secondary mechanical condensate waste design: Pipe sizing, routing, and termination areas. UMC 310.0 & UPC 807.2. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. CARLSBAD OS-1773 SEPT. 29, 2O08 * ELECTRICAL & ENERGY PLAN REVIEW • 2005 NEC * JURISDICTION: Carlsbad DATE: 09/26/08 * PLAN REVIEW NUMBER: 08-1773 * PLAN REVIEWER: Morteza Beheshti 1. Please specify a separate ground electrode and disconnecting means for the generator/ mechanical yard structure. NEC 250.32, 230.70 & 72. • ENERGY CONSERVATION 2. Please include all interior luminaries shown on the lightings on to the lighting energy forms. I.e., the restroom cove lighting? Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. CARLSBAD OS-1773 SEPT. 29, 2OO8 VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PLAN CHECK NO.: 08-1773 PREPARED BY: ALI SADRE DATE: SEPT. 29, 2008 BUILDING ADDRESS: 2502 GATEWAY ROAD BUILDING OCCUPANCY: B/F1 TYPE OF CONSTRUCTION: III-B/SPR. BUILDING PORTION office manufacturing Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 77400 CB Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) •^ 7,086,744 $14,869.68' Plan Check Fee by Ordinance Type of Review: l~~ Repetitive Fee Repeats Complete Review r Other P- Hourly Structural Only Hour Esgil Plan Review Fee $9,665.29 3,327.02 Comments: Sheet 1 of 1 macvalue.doc City of Carlsbad Public Works — Engineering DATE: /O BUILDING ADDRESS: PROJECT DESCRIPTION: BUILDING PLANCHECK CHECKLIST PLANCHECK NO.: /c-/3 ASSESSOR'S PARCEL NUMBER:ESf. VALUE: ENGINEERING DEPARTMENT/^ APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. u A Right-of-Way permit is required prior to construction of the following improvements: DENIAL >, /'/ Please see^le^atached list of outstanding issues marked wjfnu. Matke necessary corrections to plans or speclpcaticrns for compliance with applicable codes ant^ standards. Submit corrected plans and/or specifications to the Building Dept. for resubmittal to the Engineering Dept. Oolv-*he applicable sheets have been sent. /Date: By: By: Date: Date: By: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: Date: D D D D D D D ATTACHMENTS Engineering Application Dedication Checklist Improvement Checklist Neighborhood Improvement Agreement Grading Submittal Checklist Right-of-Way Permit Application and Information Sheet Storm Water Applicability Checklist/Storm Water Compliance Exemption Form ENGINEERING DEPT. CONTACT PERSON Name: KATHLEEN M. FARMER City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2741 NOTE: If there are retaining walls associated with your project, please check with the Building Department if these walls need to be pulled by separate RETAINING WALL PERMIT. 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) -602*6562 602-1052 SITE PLAN •>RD D YOUR SUBMITTAL NEEDS TO HAVE SIGNED APPROVED GRADING PLANS INCLUDED WITH YOUR PLANCK. YOUR BUILDING PLANCHECK CHECKI GRADING PLANS ARE NOT APPROVED TO DATE. ONCE THEY ARE SIGNED/APPROVED PLEASE HAVE COPIES MADE FOR BOTH CITY AND OWNER SET AND HAVE SLIP SHEETED IN YOUR PLANCK AND REQUEST TO HAVE REROUTED TO ENGINEERING. 1. Provide a fully dimensioned site plan drawn A. North Arrow B. Existing & Proposed Structures C. Existing Street Improvements D. Property Lines (show all dimensions) E. Easements DWGNO. F. Right-or-way widtn & Adjacent streets G. Driveway widths H. Existing or proposed sewer lateral I. Existing or proposed water service J. Existing or proposed irrigation service K. Submit on signed approved plans DWG No. D D D 2. Show on site plan: D D D A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography. C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Lot Number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF. Example: Tenant Improvement for 3500 SF of warehouse to 3500 SF of office. BUILDING PLANCHECK CHECKLIST ST 0ND oRD D DISCRETIONARY APPROVAL COMPLIANCE O D 4a. Project does not comply with the following Engineering Cpnditions of approval for Project No._ 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS 5.Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18.40.030. For single family residence, easement dedication will be completed by the City of Carlsbad, cost $605.00. Dedication required as follows: _ Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 W x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:Date: D D IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the BUILDING PLANCHECK CHECKLIST ,ST ND2 D 3RD D D D D checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by:Date: 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ 441.00 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. n n n n n Future public improvements required as follows: 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. n n GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill import, export and remedial). This information must be included on the plans. 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by:Date: D D . 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) 4 BUILDING PLANCHECK CHECKLIST ST1 D ND -,RD2 D n n n 7d. No Grading Permit required. 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: D n INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: NPDES PERMIT 10. Complies with the City's requirements of the National Pollutant Discharge Eliminate System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the city Engineer prior to issuance of grading or building permit, whichever occurs first. STORM WATER COMPLIANCE 10A. D Requires Project Storm Water Permit: PSP D Tier I/Tier II (Requires SWPPP) - Please complete attached forms D Exempt - Please complete attached exemption form FEES equired fees are attached No fees required BUILDING PLANCHECK CHECKLIST ..ST 2ND 3RD D O D 12c. Irrigation Use (where recycled water is available) /fn fa 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. D 13. Additional Comments: / ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D Estimate based on unconfirmed information from applicant. D Calculation based on building plancheck plan submittal. Address: 2-£ D 1 C* cjj. ^ O-J^ B|dg permit No C 1 3 OK Prepared by: / C-/ U EDU CALCULATIONS: Types of Use: <$Uj(_JL& Types of Use: Types of Use: Types of Use: APT CALCULATIONS: Types of Use: )fMJL&- Types of Use: Types of Use: Types of Use: Date: /^/(ff/Ov Checked by: List types and square footages for all uses. - O/V^-Cy Sq. Ft./Units: "H, Sf © O Sq. Ft./Units: Sq. Ft./Units: Sq. Ft./Units: List types and square footages for all uses. OnJU., Sq. Ft./Units:"T7, ^OO Sq. Ft./Units: Sq. Ft./Units: Sq. Ft./Units: Date: EDU's: | ^yQ* EDU's: EDU's: EDU's: ADT's: 33>"? ADT's: ADT's: ADT's: FEES REQUIRED. •> , ^ „ 7/ , - , WITHIN CFD: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1. PARK-IN-LIEU FEE: NW QUADRANT FEE/UNIT: D 2. TRAFFIC IMPACT FEE ADT's/UNITS: NE QUADRANT SE QUADRANT SW QUADRANT X NO. UNITS: = $_ /cr\ro >- if ~ 33^ X. X FEE/ADT: = $ D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 -"^ DIST. #2 ADT's/UNITS: X FEE/ADT: DIST. #3 ) D 4. FACILITIES MANAGEMENT FEE nZONE:_ X FEE/SQ.FT./UNIT: (4*0 Bo D 5. SEWER FEE EDU-.:X BENEFIT AREA: EDU's: ' PLDAD 6. DRAINAGE FEES ACRES: D 7. POTABLE WATER FEES UNITS CODE CONNECTION FEE HIGH /LOW_ FEE/AC: METER FEE SDCWA FEE IRRIGATION F:\FARMER\KATHY\MASTERS\FEE CALCULATION WORKSHEET.doc2008.doc Rev. 7/14/00 a PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB 08-1773 Address Bressi Ranch Lots 10-13 Planner Greg Fisher APN: Phone (760) 602-4629 213-261-01 Type of Project & Use: Office Zoning: PM General Plan: PJ_ Net Project Density:.DU/AC Facilities Management Zone: 17 CFD (in/out) #_Date of participation:.Remaining net dev acres:. Circle One (For non-residential development: Type of land used created by this permit: ) Legend: [X] Item Complete Q Item Incomplete - Needs your action Environmental Review Required: YES NO X_ TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required:YES 06/MCUP 08-08 NO TYPE SUP 07-06/PIP 07-06/PUD 08- APPROVAL/RESO. NO. PROJECT NO. SUP 07-06 6430 DATE July 16. 2008 OTHER RELATED CASES:PIP 07-06/PUD 08-06/MCUP 08-08 Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Prior to building permit issuance, project requires approval of MS 07-10: Satisfy condition #8. #11. and #12 within PUD 08-06 approval letter: satisfy condition #14 and #16 within PIP 07-06 approval letter: satisfy condition #11 within MCUP 08-08 approval letter. DD Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES_ CA Coastal Commission Authority? YES_ NO_X NO X If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): EXEMPT Habitat Management Plan Data Entry Completed? YES NO N/A If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Inclusionary Housing Fee required: YES NO N/A (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES.NO N/A (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 * Site Plan: D D Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Policy 44- Neighborhood Architectural Design Guidelines 1. Applicability: YES NO X 2. Project complies YES NO N/A DD DD D D D D Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Required. Required Required. Required. 2. Accessory structure setbacks: Front: Required Interior Side: Required Street Side: Required Rear: Required *Per approved Special Use Permit 07-06 site plan 3. Lot Coverage: Required <50% Shown: *Per SUP 07-06 Shown *Per SUP 07-06 Shown *Per SUP 07-06 " Shown *Per SUP 07-06 Shown *Per SUP 07-06 Shown *Per SUP 07-06 Shown *Per SUP 07-06 Shown *Per SUP 07-06 Shown 11% 4. Height:Required <45" building Shown 45' building/52'Protrustions 5. Parking: Spaces 281: (232 office/49 Manufacturing) Shown 296 (breakdown by uses for commercial and industrial projects required) Additional Comments Please comply with the conditions listed on page one prior to issuance of building permit. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Carlsbad Fire Department 8U3LDING DEFFo Plan Review Requirements Category: COMMBStD , COMM Date of Report: 10-16-2008 Reviewed by: Name: SMITH CONSULTING Address: STE200 12220 EL CAMINO REAL SAN DIEGO CA 92130 Permit #: CB081773 Job Name: VIASAT-3 STORY SHELL TILT-UP Job Address: 2502 GATEWAY RD CBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0003106 [NOT MET] Using Group F-l occupancy (most restrictive) as the primary occupancy, and to achieve non-separated uses (B/F-1) as for this project, they would be limited to 2-floor/stories of Group F-l. Because Carlsbad Municipal Code -17.04.230, Section 903.2 requires Automatic fire sprinklers for all buildings five-thousand (5000) square feet or more in area, they cannot be used in lieu of rated construction, for increases in floor area, or additional height/story beyond that provided in Chapter 5, Section 503. Because automatic fire sprinklers are required for all buildings >5000 S.F. they cannot be used in lieu of fire-rated construction (1-hour, etc.), to achieve the addition story or height. Because fire-resistive construction shall be required provide all appropriate details on the plans for fire resistive construction. These details shall include built-in wall fixtures, wall and ceiling protection at duct penetrations. Fire dampers shall be required at all duct and air transfer openins in ceilings, occupancy separations, etc. Smoke dampers shall be required to be installed at all air trnsfer openings in F.R. corridors and shaft enclosures. The elevator machine room is required to be separated from the remainder of the building by rated fire barriers and horizontal assemblies. Provide a smoke damper in supply air duct into the elevator machine room. Provide smoke detection in the supply air for the required air handling system for required shut-off of equipment.and how Entry: 10/16/2008 By: GR Action: CO c/3 z 11 3 z Special Insp.z "Ow R> 2 § 1 Z -o 3 z oT]D Z I z 3 1 ? I D 1 5 1 O. c Engineering |:zf 3 3 1 B 2 CDcs1' ^5S n I [ HazMat/Air Quail•? !s- *rlbp Tl 3'| EngineeringT3 15'04 Ss3'en ! ApprovedS 5