Loading...
HomeMy WebLinkAbout2505 CHESTNUT AVE; ; CB101754; Permit09-24-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Mechanical Permit Permit No: CB101754 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC#: Project Title: 2505 CHESTNUT AV CBAD MECH 1672703900 $0.00 Lot#: OCONNOR: INSTALL DIRECT VENT HEATER (GARNET-T/QUADRA FIRE) IN MASTER BED Status: ISSUED Applied: 09/23/2010 Entered By: JMA Plan Approved: 09/24/2010 Issued: 09/24/2010 Inspect Area: Applicant: OCONNOR MICHAEL F&DIANE V 2505 CHESTNUT AVE CARLSBAD CA 92010 Owner: OCONNOR MICHAEL F&DIANE V 2505 CHESTNUT AVE CARLSBAD CA 92010 Mechanical Issue Fee Install/Furn/Ducts/Heat Pumps Fee Fireplace Installation Fee Exhaust Fan Fee Installation/Relocation Vent Fee Hood Fee Boiler/Compressor to 15HP Fee Other Additional Fees TOTAL PERMIT FEES 1 0 0 1 0 0 $15.00 $9.00 $0.00 $0.00 $4.50 $0.00 $0.00 $27.00 $0.00 $55.50 Total Fees:$55.50 Total Payments To Date:$55.50 Balance Due:$0.00 Inspector: FINAL APPROVAL Date: ?-/*4fa 11 Clearance: NOTICE: Please take NOTICE tip approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. Building Permit Appli ' 1635 Faraday Ave., Carlsbad, CA NJ7 CITY OF 760-602-2717/2718/27 f"°ARi ^RAD Fax:760-602-8558\-./»r%L«jO/*L«' www.carlsbadca.gov JOB ADDRESS /"»// 4- \*f Af/^ CT/PROJECT* LOT* PHASE* # OF UNITS # BEDROOMS Plan Check No. G(3^O 11 S*4CQtion l \ 92008 Est. ValueiyPlan Ck. Deposit Date ^ {23 ( ( ^) SWPP SUITE#/SPACE#/UNIT# APN # BATHROOMS TENANT BUSINESS NAME CONSTR.TYPE OCC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) MtfAll Dimx vfrtr <s#3 *rw& fajtf&i} M &&0e&M ' EXISTING USE PROPOSED USE GARAGE (SF) CONTACT NAME (If Different Fom Applicant) ADDRESS CITY STATE ZIP PHONE FAX EMAIL PROPERTY OWNER NAME II /, ADDRESS yflfYC- A*/ rTfri'i(-^ff\fY CITY STATE ZIP PHONE FAX EMAIL ARCH/DESIGNER NAME & ADDRESS STATE UC. # PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS YES D #_ NO D YES D NO D YES D NO D APPUCANTNAME^^^ /^A/£ O'COA/A/O fi~ ADDRESS ' CITY STATE ZIP s** PH°7^<y7?-^zy FAX EMAIL CONTRACTOR BUS. NAME ADDRESS CITY STATE ZIP PHONE FAX EMAIL STATE LIC.# CLASS CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars {$500}). Workers' Compensation Declaration: ' hereby affirm under penalty of perjury one of the following declarations: G I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. O I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. _ ; _ ; _ Policy No. _ Expiration Date _ This section need not be completed if the permit is for one hundred dollars ($100) or less. LTI Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE CJAGENT DATE / hereby affirm that I am exempt from Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of iroperty who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). I am exempt under Section _.Business and Professions Code for this reason: D No1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement, a Yes 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of wo*): -A. PROPERTY OWNER SIGNATURE LlAGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? O Yes O No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYes DNo IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {See. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relatingto building construction. I hereby authorize representative of Hie City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if Ihe building or work authorized by such permit is not commenced within 180 days from the date of such permit or if thav&teiing or ySrk auttiofftedj^such permit is suspended or abandoned at any time after the work is commenced for a pericjl of 180 days (Section 106.4.4 Uniform Building Code). ^APPLICANT'S SIGNATURE /f///f/il I//*-4-.,[} l^M jf^^" DATE d for a penof ot 180 days (Sectio t/10/10 I City of Carlsbad Bldg Inspection Request For: 02/24/2011 Permit* CB101754 Title: OCONNOR: INSTALL DIRECT VENT Description: HEATER (GARNET-T/QUADRA FIRE) IN MASTER BED Inspector Assignment: TP 2505 CHESTNUT AV Lot: Type: MECH Sub Type: Job Address: Suite: Location: OWNER OCONNOR MICHAEL F&DIANE V Owner: OCONNOR MICHAEL F&DIANE V Remarks: noon time inspection Total Time: Phone: 76047 Inspector: Requested By: MICHAEL Entered By: CHRISTINE CD Description 43 AirCond/Furnace Set 49 Final Mechanical Act Comments Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description Act Insp Comments 09/27/2010 23 Gas/Test/Repairs CO TP NEE TEST FOR GAS LINE 09/27/2010 44 Rough/Ducts/Dampers NR TP 09/27/2010 49 Final Mechanical NR TP BUILDING Development Services ^jte{, Building Division ^ CITY OF Plan CheCk 1635 Faraday Avenue CARLSBAD Comments 750-602-2719www.carlsbadca.gov By: Steve Borossay (Contact Hours for Steve: Tues.-Fri., 1pm - 5pm) Phone: 760-602-7541 Permit; <^g> [O \ 9 S"^~ Address- ^- STO £7 f\Hg ^-f^1^ ^ Hate- * When corrections from all departments are received please run new prints. » | | Provide: A statement on the Title Sheet of the plans stating that the project shall comply with the 2007 CA Building Code, 2007 CMC, 2007 CPC, 2007 CEC and the 2008 CA Energy Efficiency Standards. I I Provide: A note titled "Scope of Work" describing the work to be performed under this permit. Approved on: 6*4 BY APPROVED SEP 2 4 2010 City of CARLSBAD BUILDING DEPT, ^5 of o Don't let its size fool you—the Garnet-T is a charrjpidri.' £,. ^ heater with a big heart. A diminutive JoojtRriritajriaJrnpjps| design features combine to make this srriallesljiierrjBef,^ r' Quadra-Fire family perfect for the«bedroornj-fieri^r^in1 The Garnet-T is designed to be bdth"attreiE|iyl devoted to the zone heating concept-^fieal not the entire house. The TrueGlow Burner, an exclusive from Quadra-Fire, sets a new standard for realismS The ceramic burner is molded from real wood pieces and coals. Flames rise from gas ports distributed throughout the glowing coal bed a/id logs, producing an Incredibly active and varied fire. No need to hide the burner anymore—the TrueG!6wBufperv t center stage, with an appearance that is ph^nomjjnat it's burning or not. •• - Standard Features • Operable cabinet style doors (Non-operable doors also available, matte black only) • Tube heat exchanger • Strength & beauty of cast iron • Matte black finish • One-hand lighting • Ceramic burner & Pyroglo logs • Natural convection neater • Heats without power • Bedroom/mobile home approved • Limited Lifetime Warranty Options • Porcelain enamel finish in mahogany • Baked durable finish in sienna bronze and willow • Firescreen • Circulation blower • Thermostat & remote control • DV Slim Line wall thimble Cover photo: Garnet-T in optional sienna bronze finish with operable doors Sienna Bronze Dimensions -17-7/8"--15-3/8' 23-5/8"17-34' E F G H Side of stove top to side wall 6" Rear of stove to back wall 2" Corner of stove top to side wall (left) 2" Minimum alcove height 43" Maximum alcove depth 36" Minimum alcove width 30" Top of stove to alcove ceiling 19-3/8" Mantel clearance 19-1/2" No floor protection required. May be installed directly on carpet or flooring. Technical & Performance Data Width 17-7/8" Height 23-5/8" Depth 15-3/8" Shipping weight 160 Ibs. Flue size 6-5/8" Standing pilot ignition Yes Mobile home approved Yes Bedroom approved Yes Heating capacity Up to 700 sq. ft.* Btu/Hour Input NG 12,000 -17,000 Btu/Hour Input LP 13,000 -17,000 Efficiency up to 83%** Convection blower 160cfm Limited Lifetime Warrantyt The strongest in the industry, Quadra-Fire provides a limited lifetime warranty on gas;burriing "products for their most important aspects: firebox and heat exchanger. fForfull warranty details go to www.quadrafire.com IMPORTANT - READ BEFORE YOU INSTALL! Refer to the Owner/Installation Manual for complete clearance requirements and specifications. The images and descriptions in this brochure are provided to assist you in product selection only. Actual product appearance, including flame, maydiffer from product images. *Heating capacity rating is to be used as a guideline only. Actual performance may differ slightly due to climate, building con- struction and condition, amount and quality of insulation, location of the heater, and air movement in the room. "Canadian: P.4.1-02 68%NG/70%LP. Quadra-Fire is a registered trademark of Hearth & Home Technologies. Product specifications and pricing subject to change without notice. The Quadra-Fire Garnet-T direct vent gas appliance listed to ANSI standard Z21.88a-2000/CSA 2.33a-MOO Vented Gas Fireplace Heaters and applicable sections of UL307b Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CGA 2.17-M91 "Gas Fired Appliances for Use at High Altitude," by OMNI-Test Laboratories, Inc., Beaverton, OR. Available From: 1445 North Highway, Colville, WA 99114 www.quadrafire.com • 800-926-4356 FIREPLACES PLUS, INC. 1833 DIAMOND ST., STE. 101 SAN MARCOS, CA 92078 760-752-7789 firep4acesplusinc.com QDF-100SU-0908 Ouaoaa-HPE GARNET-T DIRECT VENT ROOM HEATER Owner's Manual Installation and Operation Model: GARNET-MBK GARNET-D-MBK GARNET-D-PMH GARNET-D-CSB GARNET-D-CWL Tntid *Mf!ifW^B Portl.nd LliUd by ^hMH^^V Orogon USA Ci'i'iUS OMNI-T«tLibontori«, Inc. CAUTION DO NOT DISCARD THIS MANUAL Important operating and • Read, understand and • Leave this manual with maintenance instructions follow these instructions party responsible for use included. for safe installation and and operation. operation. WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. • Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building. - Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. - If you cannot reach your gas supplier, call the fire department. • Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory-trained professionals, or technicians supervised by an NFI certified professional. A WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • Do not touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in the same room as appliance • Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials. • Keep clothing, furniture, draperies and other combustibles away. In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fitter. See Table of Contents for additional Commonwealth of Mas- sachusetts requirements. This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer's instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240MH. This appliance is only for use with the type(s) of gas indicated on the rating plate. www.quadrafire.com 7016-127F September 1,2008 1Listing and Code Approvals A. Appliance Certification MODEL: LABORATORY: TYPE: STANDARD: Gamet-T OMNI Test Laboratories, Inc. 061-S-35c-5 Direct Vent Gas Heater ANSI Z21 .88a-2003 • CSA 2.33a-2003 • UL307b-CAN/CBA2.17-M91 The product is listed to ANSI standards for "Vented Gas Appliance Heaters" and applicable sections of "Gas Burning Heating Appliances for Manufactured Homes and Recre- ational Vehicles" and "Gas Fired Appliances for use at High Altitudes". Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4. When installed, the appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. B. Glass Specifications This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada. C. BTU Specifications Model (US or Canada) Garnet-T (NG) Garnet-T (LP) Maximum Input BID 17,000 17,000 Minimum Input BTU 12,000 13,000 Orifice Size (DMS) 49 56 *Steady State % 76.93 78.19 "P.4 % 67.38 69.52 Thermal efficiency maximum pipe with blower on. ** Canada minimum pipe. D. High Altitude Installations Omni-Test Laboratories listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada. When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility. If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities. E. Non-Combustible Materials Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at750°C, shall be considered non-combustible materials. F. Combustible Materials Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other materials that can ignite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials. WARNING Do NOT use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water. Page 4 Quadra-Fire • Garnet-T • 7016-127F September 1,2008 3Appliance Location and Clearances NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. A WARNING Fire Risk Provide adequate clearance: • Around air openings • To combustibles • For service access Locate appliance away from traffic areas. A. Selecting Appliance Location When selecting a location for your appliance it is important to consider the required clearances to walls (see Figure 3.1). NOTE: For actual appliance dimensions refer to Section 12. A WARNING Fire Risk. • Locate and install appliance to all clearance specifications in manual. B. Clearances "A" measurement is fromstove top, not side H -Alcove Figure 3.1 It is permissible to place the appliance on carpet. CAUTION Some carpet materials may be sensitive to radiant heat from the appliance causing discoloration or odor. NOTE: Flooring beneath appliance may reach 90 degrees plus room ambient temperature. Check with flooring manufacturer for maximum temperature allowed on flooring surfaces. A WARNING Fire Risk. Odor Risk. Tipping Risk • Install appliance on a stable, level platform/ floor strong enough to support appliance without tipping. • USE wood flooring, ceramic tile, brick hearth or high pressure laminate flooring applied directly over the sub-flooring material. September 1,2008 Quadra-Fire • Garnet-T • 7016-127F Page 7 • VENT TERMINAL •• AIR SUPPLY INLET ' AREA WHERE TERMINAL IS NOT PERMITTED A B F G H J = : 12 Inches clearances above grade, veran- (See Note i) £jai porch, deck or balcony = 12 Inches clearances to window or door that may be opened, or to per- manently closed window. (Glass) = 18 Inches vertical clearance to unventilat- ed soffit or to ventilated soffit lo- cated above the terminal *30 inches for vinyl dad soffits and below electrical service : 9 inches clearance to outside corner : 6 inches clearance to inside comer = 3 ft. (Canada) not to be installed above a gas meter/regulatorassembly within 3 feet (90cm) horizontally from the center-line of the regulator 3 ft clearance to gas service regula- tor vent outlet 9 inches (U.S.A.) 12 inches (Canada )clearance to non-mechanical air supply inlet to building or the combustion air Inlet to any other appliance K = 3ft.(U.S.A.) 6 ft. (Canada) clearance to a mechanical (powered) air supply Inlet L** = 7ft clearance above paved (s*e Note i) sidewalk or a paved driveway located on public property M*** = 16 Inches clearance under veranda, porch, deck, balcony or over- hang 42 Inches..- vinyl S = 6 inches , (See Note 3) T = 12 inches , (See Note 3) . clearance from sides of electrical service . clearance above electrical service Alcove App N * 6inch< 12indp = an. 1 cap 2 caps 3 caps 4 caps ilicatlons js non-v ies vinyl QH.N 3 feet 6 feet 9 feet 12 feet nyl sidewalls sidewalls "MAX 2 X Q ACTUAL 1*Q ACTUAL 2/3 X Q ACTUAL 1/2xQ«.TUAL QHN • # termination caps x 3 R,,tt • (2 1 * termination caps) x OACTUAI ** a vent shall not terminate directly above a sidewalk or paved driveway which Is located between two single family dwellings and serves both dwellings. *** only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2. NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap is suggested. (See vents components pages.) NOTE 2: Termination in an alcove space (spaces only open on one side and without an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be at least 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap. NOTE 3: Location of the vent termination must not interfere with access to the electrical service. Figure 4.4 NOTE: Local codes or regulations may require different clearances. NOTE: Termination caps may be hot. Consider their proximity to doors or other traffic areas. WARNING: In the U.S.: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as slated in the instructions, In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow side wall, overhang and ground clearances as stated in the Instructions. Quadra-Fire assumes no responsibility for the Improper perfor- mance of the appliance when the venting system does not meet these requirements. CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PRO- TECTOR KIT BE INSTALLED. September 1, 2008 Quadra-Fire • Garnet-T • 7016-127F Page 9 4Termination Locations A. Vent Termination Minimum Clearances W i A WARNING Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as specified. • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause fire. Measure vertical clearances from this surface. Measure horizontal clearances from this surface. (See Figure 4.4 for specific clearances.) Figure 4.1 Termination Clearances A •B C GasTermination Eln. 20 In. 18 In. Wood ft Fuel OilTermination 20 In. mln. 24 In. mln. 18 In. Comments Horizontal distance between terminations Distance to perpendicular wall Vertical distance between terminations Figure 4.2 Multiple Vertical Termination HORIZONTAL OVERHANG GAS DIRECT VEI TERMINATION CAP ROOF PITCH X/12 H (WIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roof Pitch H fMln.l Ft. Flat to 6/12 1.0* Over 6/12 to .7/1.2 1.25* Over 7/12 to 8/12 1.5* Over 8/12 to 9/12 2.0* Over 9/12 to 10/12 2.5* Over 10/12 to 11/12 3.25 Over 11/12 to 12/12 4.0 Over 12/12 to 14/12 5.0 Over 14/12 to 16/12 , 6.0 Over 16/12 to 18/12 7.0 Over 18/12 to 20/12 7.5 Over 20/12 to 21/12 8.0 * 3 foot minimum in snow regions Figure 4.3 Minimum Height from Roof to Lowest Discharge Opening Figure 4.3 specifies minimum vent heights for various pitched roofs. Page 8 Quadra-Fire • Garnet-T • 7016-127F September 1,2008 FIG. A 90 DEGREE ELBOW Use HEAT SHIELD or WALL THIMBLE Place mark where protrudes through exterior wall to cut off excess 90° ELBOW center line — TRIM RING SOLID OR VENTILATED TERMINATION CAP PIPE LENGTH FIG. B 45 DEGREE ELBOW TRIM RING NOTE: Wall Thimble removed to show Heat Shield HEAT SHIELD OVER PIPE 45° Elbow 2 in. (51mm) Clearance from stove comer to combustible wall FIG. C MINIMUM CLEARANCE INTERIOR WALL (2 in. (51mm) clearance from rear of stove) CENTER LINE 2 in. 951mm) Clearance from stove corner to combustible wall. MINIMUM OF 6 in. (152Mm) OF PIPE THROUGH THE WALL .WALL THIMBLE HEAT SHIELD OVER TOP HALF OF PIPE TERMINATION CAP • TRIM RING Figure 5.33 Page 24 Quadra-Fire • Garnet-T • 7016-127F September 1,2008