HomeMy WebLinkAbout2505 PALOMAR AIRPORT RD; ; CB121226; Permit06-26-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB121226 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2505 PALOMAR AIRPORT RD CBADSt 100 Tl Sub Type COMM 2130201800 Lot# 0 $117,055 00 Construction Type 5B Reference # CHIPOTLE - 2,003 SF SHELL TO RESTAURANT Status Applied Entered By Plan Approved Issued Inspect Area Plan Ctieck # ISSUED 06/29/2012 LSM 06/26/2013 06/26/2013 Applicant BRETT GRAY STE 304 8826 SANTA FE DR OVERLAND PARK KS 66212 913-341-2466 Owner COUNTY OF SAN DIEGO PUBLIC AGENCY OOOOO Building Permit $766 18 Meter Size Add'l Building Permit Fee $0 00 Add'l Red Water Con Fee $0 00 Plan Check $536 33 Meter Fee $0 00 Add'l Building Permit Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $24 58 PFF (3105540) $2,130 40 Park Fee $0 00 PFF (4305540) $1,966 52 LFM Fee $0 00 License Tax (3104193) $0 00 Bndge Fee $0 00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $0 00 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $0 00 Renewal Fee $0 00 PLUMBING TOTAL $262 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $235 00 Other Building Fee $0 00 MECHANICAL TOTAL $118 00 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $0 00 Add'l Pot Water Con Fee $0 00 Redev Parking Fee $0 00 Reel Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SB1473) Fee $4 00 HMP Fee 99 Fire Expedidted Plan Review $565 00 Green Bldg Standards Plan Chk 99 Fire Expedidted Plan Review TOTAL PERMIT FE ES $6,608 01 Total Fees $6,608 01 Total Payments To Date $6,608 01 Balance Due $0.00 Inspector FINAL Date .APPROVAL Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refen-ed to as "fees/exactions" You have 90 days from the date this pemiit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection v^ith this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 11 nc ruL.LUfiinu MrrnuvMuo ncwuincu rniwn i u rcnmi i loouMnuc i i rL^nmnu [ i cnuinccnmu i i Duii-uinu | | nnc i i ncML i I I n/u-mHimrv/u i CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave , Carlsbad, CA 92008 760-602-2717/2718/2719 Fax 760-602-8558 www carlsbadca gov Plan Check No.(2j2> { | Q-d-^ Est. Value / \1 OS^ Plan Ck. Deposit ^ S3 SWPPP JOB ADDRESS 2505 Palomar Airport Road SUITE#/SPACE#/UNrr# ^lOO ^\e> -030 -1^ CO CT/PROJECT# # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME (IH-IPOTLB CONSTR TYPE OCC GROUP DESCRIPTION OF WORK Include Square Feet of Affected Area(s) Restaurant Tenant Finish EXISTING USE New Shell PROPOSED USE Resturant GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESQ# N0| I AIR CONDITIONING YES I I NO I I FIRE SPRINKLERS YES I |NO| I APPUCANT NAME (Primary Contact) Brett Gray (Agent for Chipotle Mexican Gnll) APPLICANT NAME f Secondary Confacfl ~ / / ADDRESS 8826 Santa Fe Dr, Suite 304 ADJ CITY Overland Park STATE KS ZIP 66212 CITY ^ , STATE PHONE 913-341-2466 FAX 913-341-2455 ^HONE _ FAX . , . .r ^ EMAIL EMAIL bgray@ddg bz '6^^/7 d<^//<3 b^i^(^. Co ^ PROPERTY OWNER NAME Sudberry Properties (Joseph V Madden) CONTRACTOR BUS NAME ADDRESS 5465 Morehouse Dnve, Suite 260 ftDDRESS CITY San Diego STATE CA ZIP 92121 CITY STATE ZIP r PHONE 858-546-3000 Ext 521 FAX PHONE. FAX 7/4- 6n^2^o ^(4 Cttoz^^i EMAIL |oe@sudprop conn EMAIL ARCH/DESIGNER NAME & ADDRESS John M Dungan 6 CITY BUS LIC#, (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issualhc^, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions ofthe Contractor s License Law (Chapter 9 commending with Section 7000 of Division 3 ofthe Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of SecUon 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) Workers' Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations f have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued I have and will maintain workers' compensation as required bv Section 3ZB0of the Labor Code, for the performance of the work for which this permit is issued My workers' compensation insurance carrier and policy number are Insurance Co Expiration Date. //// This section need not be completed if the permit is for one hundred dollars ($100) or less I I Certificate of Exemption I certify that in the performance of the work for which this pemiit is issued I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to cnminal penalties and civil fines up to one Itundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees ^CONTRACTOR SIGNATURE ^^^^^^^-^l^ f y.^<^^ 25" PI AGENT DATE ^f'^V /( / hereby affirm that I am exempt from Contractor's License Law for the following reason I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions CoAe The Contractor's License Law does nol apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have Ihe burden of proving that he did not build or improve for the purpose of sale) I I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law) I I I am exempt under Section _ .Business and Professions Code for this reason 1 I peisonally plan to provide the major labor and matenals for construction of the proposed property improvement •Yes FINO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number) 4 I plan to provide portions of the wori(, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) ^gS"PROPERTY OWNER SIGNATURE QAGENT DATE 06/23/12 Is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registration form or nsk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account AcP Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management distncP Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site'' Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF 6CCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirni that there is a construction lending agency for the perfomiance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I ceitafythat I have lead the applicataon and state thattheabove infomiation iscorrectandthattheinfbmiabon on the plans isac^ I ajjieetocomply with all Cityordinancesand State laws relabng to buildingconstnicbon I hereby aultionze representative of the City of Carisbad to enter upon ttie above mentioned property for inspecton purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA. An OSHA pemiit is required for excavations over 5'0' deep and demolition or constmction of structures over 3 stones in height EXPIRATION Every permit issued by the Building Official under ttie provisions of this Code shall expire by limitation and become null and void if the building or wori( authonzed by such permit is not commenced within 180 days tram the date of such permit or if the building or wori( authonzed by;5dch permit is suspended oi abandoned at any tme after the wori< is commenced for a penod of 180 days (Secton 106 4 4 Unifonn Building Code) yglTAPPLICANT'S SIGNATURE DATE 06/23/12 STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. C E R Tl CAT IE OF OCC |CY (Commeirj Pfojeclis OnllyJ Fax (760) 602-8560, Email www buildinataicarlsbadca gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carisbad, California 92008 C0# (Office Use Only) UTTice use oniyj y CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS ' STATE zip" CITY * STATE „ ^^Jl ^ ZIP" PHONE TFAX CITY Carlsbad CA EMAIL OCCUPANT S BUS LIC No PICK UP CONTACT (Listed above) CONTRACTOR (On Pg 1) MAIL TO CONTACT (Listed above) CONTRACTOR (On Pg 1) MAIL/FAX TO OTHER OCCUPANT (Listed above) OCCUPANT (Listed above) ASSOCIATED CEi#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ^APPLICANT'S SIGNATURE k^A— DATE 1635 Faraday Ave., Carlsbad, CA 92008 Inspection List Permits CB121226 Type Tl COMM Date 10/03/2013 09/27/2013 09/27/2013 09/26/2013 09/26/2013 09/11/2013 08/28/2013 08/20/2013 08/14/2013 08/07/2013 07/31/2013 07/26/2013 07/25/2013 Inspection Item 89 Final Combo Final Structural Final Combo Final Combo Final Combo T-Bar Gas/Test/Repairs 19 89 89 89 85 23 17 84 44 11 31 21 Intenor Lath/Drywall Rough Combo Rough/Ducts/Dampers Ftg/Foundation/Piers Underground/Conduit-Winn Underground/Under Floor Inspector PD PD MC PD PD PD PD PD PD PB PB Act AP RI CO RI PA AP AP AP AP AP AP AP AP CHIPOTLE - 2,003 SF SHELL TO RESTAURANT Comments COF SEE CARD Thursday, October 03, 2013 Page 1 of 1 ^ cI rv OF CARLSBAD Building Division INIP.ECTION RECORD IWSPECTION RECORD CARD W!TH APPROVED PLANS MUST BE KEPT ON THE JOB CALL BEFORE 3:30.pm FOR NEXT WORK DAY INSPECTION FOR BUILDING INSPECTION CALL: 760-602-2725 DATE C? (Z-C^ 1(3 CB121226 2505 PALOMAR AIRPORT RD 100 CHIPOTLE - 2,003 SF SHELL TO RESTAURANT Tl COMM Lot# BRETT GRAY RD COPY Required for Final ff Checked Date Inspector Notes • Planning/Landscape 760-944-8463 • CM&I (Engineering Inspections) 760-438 3891 , Fire Prevention 760-602-4660 Q Land DeV Engineering 760-4J8-2740 • Type of Inspection FOUNDATION Date Inspector Type of Inspection FRICAL Date ELECTRIC UNDERGROUND • UFER Inspector REINFORCED STEEL ROUGH ELECTRIC WALLS MASONRY ROUGH ELECTRIC CEILING • GROUT • WALL DRAINS • ELECTRIC SERVICE • TEMPORARY TILT PANELS • BONDING D POOL POUR STRIPS PHOTOVOLTAIC COLUtiftN FOOTINGS FINAL SUBFRAME • FLOOR • CEILING ROOF SHEATHING ll UNDERGROUND DUCTS & PIPING f-Jti-ff EXT, SHEAR PANELS f €'7 < ,.atUCT& PLEM • REF PIPING FRAME HEAT AIR COND. SYSTEMS INSULATION VENTIALTING SYSTEMS EXTERIOR LATH FINAL INTERIOR LATH & DRYWALL FINAL OCCUPANCY Date • SEWER & BL/CO O PL/CO Inspector ii XAE'SWREI A/S UNDERGROUND VISUAL Date Inspector UNDERGROUND • WASTE • WATER TOP OUT p-^VSTE ^HlWATER i '1*4 •^3 A/S UNDERGROUND HYDRO A/S UNDERGROUND FLUSH TUB & SHOWER PAN 4 A/S OVERHEAD VISUAL • GAS TEST • GAS PIPING A/S OVERHEAD HYDROSTATIC J'lt •' .lit • WATER HEATER • SOUR WATER A/S FINAL FINAL F/A ROUGH-IN F/A FINAL 600 - PRE CONSTRUCTION MEETING FIXED EXTINGUISHING SYSTEM ROUGH-IN 603 - FOLLOW UP FIXED EXTING SYSTEM HYDROSTATIC TEST 605-NOTICETO CLEAN FIXED EXTINGUISHING SYSTEM FINAL 607-WRIHEN WARNING MEDICALGAS PRESS.URETEST 609-NOTICE OF VIOUTION MEDICAL GAS FINAL 610- VERBAL WARNING FINAL FINAL SEE BACK F=0R3=K;1AL NOTE CITY OF CARLSBAD ESTIMATE OF BUILDING PERMIT FEES B-40 Development Services Building Division 1635 Faraday Avenue 760-602-2719 760-602-8558 FAX www carlsbadca gov Contact BREH GRAY Email BGRAY@DDG BZ Phon^i^) 913 341-2466 Fax 913 341-2455 213-020-18-00 Project Address 2505 PALOMAR AIRPORT RD APN (Required) _ Description of Project RESTAURANT TENANT IMPROVEMENT Construction Type SB Describe COWIWIERCiAL use-present & future (Asm 10,000sf shell, or, if improving 5,000sf office to office/3,500sf warehouse to office) 2003 SF COLD SHELL TO FINISHED RESTAURANT Describe RESIDENTIAL use of Building (As in 2300sf Hvmg/SOOsf garage/200sf deck) Sprinklered? / Yes No Air Conditioned"? V Yes No DATE 5/8/2012 VALUATION $ 117,055 PLANNING Redevelopment Parking Fee Habitat Management Plan Fee HMP Affordable Housing Fee BUILDING Building Permit Plan Check Strong Motion Green Building Community Facilities District Fee CFD LandUse ImpArea FY Annex Fartor Public Facilities Fee PFF Residential FireSpnnklers Plumbing. Electrical Mechanical Stormwater SCHOOL DISTRICT Carlsbad 760-331-5000 $76618 $536 33 $2500 $154 00 N/A $4,09694 $NEED $ SPECIFIC $DATA $ 100 00 ENGINEERING Bndge & Thorogfl BTD #2 BTD #3 Local Facilities Management Zone Fee LFM: Park in Lieu Drainage Fee Water Meter Size (Potable) Includes meter, connection, SDCMM Zees Meter Fee (Irr) Size Sewer Connection Fee Sewer Benefit Fee Traffic Impact Fee 4 \A\o This estimate I's provided as a service to assist you in compiling projected costs of construction Please note • Fees may increase without pnor notice • Costs for other preliminary processes i e , grading, coastal or landscaping permits, etc are not included in this estimate • Fees stated herein are best faith estimates only and are not meant as final or binding 1 of 1 Rev 01/11 EsGil Corporation In (Partners Htp with government for (BmCding Safety DATE 101Zl112 JURISDICTION City of Carlsbad PLAN CHECK NO 12-1226 SET III PROJECT ADDRESS 2505 Palomar Airport Rd Suite 100 PROJECT NAME Chipotle - TI XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to IXI EsGil Corporation staff did not advise the applicant that the plan check has been completed I I EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # IVIail Telephone Fax In Person • REMARKS By Doug Moody Enclosures EsGil Corporation • GA • EJ • PC 10/25/12 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGii Corporation In (Partnersfiip witfi government for (BuiCcfing Safety DATE 9/11/12 • AEPy€ANT JURISDICTION City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 12-1226 SET II PROJECT ADDRESS 2505 Palomar Airport Rd Suite 100 PROJECT NAME Chipotle - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X The applicant's copy of the check list has been sent to Brett Gray 8826 Santa Fe Drive Suite 304, Overland Park, KS 66212 Email bgrav(S)ddq bz, msmith(ajddg bz I I EsGil Corporation staff did not advise the applicant that the plan check has been completed X EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Brett Gray Telephone # 913-341-2466 Date contacted llii \)l (by Fax # 913-341-2455 ^Mail --^Telephone Fax ~^ In Person • REMARKS By Doug Moody Enclosures EsGil Corporation • GA • EJ • PC 9/4/12 9320 Chesapeake Dnve, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 12-1226 9/11/12 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industnal projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 1 Please review the requirements, revise the plans appropriately and impnnt on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans Unable to find on the plans. 2 Please revise the plumbing plans to show the total aggregate vent area to be equal to the required sewer size per section 904 1 of the UPC (A minimum of 7 06 square inches) Please revise the venting it appears several vents are undersized. 4 Detail how floor dram trap seal is to be maintained UPC Section 1007 0 (floor dram trap pnming at the restrooms) No specification were provided in the fixture schedule or shown on the water line plans. 5 Please have the principle designer check the appropnate box(s) and complete the Statement of Compliance System Acceptance section ofthe LTG-1-C part 4 of 4 documents The lighting plans indicate a Lighting control panel and the LTG forms show an occupancy sensor? Please revise the plans and the LTG forms to be consistent. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc City of Carlsbad 12-1226 9/11/12 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly descnbe them and where they are located in the plans Have changes been made to the plans not resulting from this correction lisf? Please indicate Yes • No • The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you EsGil Corporation In (Partnersfiip witfi government for <ButCding Safety DATE 7/10/12 • APPUQANT •(JURIST JURISDICTION City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 12-1226 SET I PROJECT ADDRESS 2505 Palomar Airport Rd Suite 100 PROJECT NAME Chipotle - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person X The applicant's copy of the check list has been sent to Brett Gray 8826 Santa Fe Drive Suite 304, Overland Park, KS 66212 Email bgrav@ddg bz, msmith@ddg bz I I EsGil Corporation staff did not advise the applicant that the plan check has been completed IX EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Brett Gray [uit^] Telephone # 913-341-2466 Date contacted l(iof/z- (by ^) Fax # 913-341-2455 6 Maik^ Telephone^ Fax In Person n REMARKS By Doug Moody Enclosures EsGil Corporation • GA • EJ • PC 7/2/12 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 7/10/12 12-1226 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 12-1226 JURISDICTION City of Carlsbad OCCUPANCY A2 USE Restaurant TYPE OF CONSTRUCTION VB ACTUAL AREA 1970sf ALLOWABLE FLOOR AREA STORIES 1 HEIGHT SPRINKLERS'? YES OCCUPANT LOAD 57 REMARKS DATE PLANS RECEIVED BY JURISDICTION 6/29/12 DATE PLANS RECEIVED BY ESGIL CORPORATION 7/2/12 DATE INITIAL PLAN REVIEW COMPLETED 7/10/12 PLAN REVIEEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department, Fire Department or other departments Clearance from those departments may be required pnor to the issuance of a building permit Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 12-1226 7/10/12 Please make all corrections on the ongmal tracings, as requested in the correction list Submit three sets of plans for commercial/industnal projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete 1 Please review the requirements, revise the plans appropnately and impnnt on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans 2 Please revise the plumbing plans to show the total aggregate vent area to be equal to the required sewer size per section 904 1 of the UPC (A minimum of 7 06 square inches) 3 The floor dram does not have a basin designed to prevent splashing from dram lines indirected to the floor dram UPC, Section 804 1 Please revise the plumbing plans to show the indirect waste to discharge to an approved fixture such as a floor sink 804 1 ofthe UPC 4 Detail how floor dram trap seal is to be maintained UPC Section 1007 0 (floor dram trap pnming at the restrooms) 5 Please have the pnnciple designer check the appropnate box(s) and complete the Statement of Compliance System Acceptance section of the LTG-1-C part 4 of 4 documents 6 Provide complete kitchen hood plans, details, and calculations to show compliance with UMC, Chapter 5, Part II • Provide the UL listing card showing the exhaust sizing requirements used for the hoods • Show the required replacement air for each kitchen hood to replenish the air exhausted The exhaust and make-up air systems shall be connected by an electncal interlocking switch UMC 511 3 7 Please revise the plans to show where food or dnnk is served at a counter exceeding 34" in height for the consumption by customers seated or standing at City of Carlsbad 12-1226 7/10/12 the counter, a portion ofthe mam counter which is 60" in length minimum shall be provided in compliance with Section 1122B (28" to 34" in height) 8 Show that grab bars comply with the following, per Section 1115B 4 1 a) They shall be securely attached 33" above the floor, and parallel NOTE Where a tank-type toilet is used which obstructs placement ofthe rear grab bar at 33", the rear grab bar only may be installed as high as 36" To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please bnefly descnbe them and where they are located in the plans Have changes been made to the plans not resulting from this correction lisf? Please indicate Yes • No • The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad 12-1226 7/10/12 ^DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 12-1226 PREPARED BY Doug Moody DATE 7/10/12 BUILDING ADDRESS 2505 Palomar Airport Rd Suite 100 BUILDING OCCUPANCY A2 TYPE OF CONSTRUCTION VB BUILDING PORTION AREA (Sq Ft) Valu ation Multiplier Reg Mod VALUE ($) Tl 1970 City Valuation 117,055 Air Conditioning Fire Spnnklers TOTAL VALUE 117,055 Junsdction Code cb By Ordinance Bldg Permit Fee by Ordinanoe Plan Qieck Fee by Ordinance Type of Review Q Re petit ve Fee ~ Repeats [v] Complete Review • Other |—I Hourly EsGil Fee • Structural Only Hr @ $766.18 $498.02 $429.06 Comnnents Sheet 1 of 1 macvalue doc + <c%> ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 08/06/12 PROJECT NAME: CHIPOTLE MEXICAN FOOD PROJECT ID: CB12-1226 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2505 PALOMAR AIRPORDRD APN: 215-020-18 VALUATION: $117,055 ' This plan check review is complete and has been APPROVED by the ENGINEERING - Division. By: KATHLEEN LAWRENCE A Final Inspection by the Division is required j lives [TJNO I.... This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: b ^yr'Mo®'^^^^ Vou may also have corrections from one or more ofthe divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the followmg reviewer as marked- Vi;-.:. ^> J - 760-602:4610^- * ' U ENGINEERING , ' 76O|602-275O^H-• ' j ~' Chris Sexton ; 760-602-4624 Chris Sexton@carlsbadca gov ,'7; Kathleen Lawrence [V.. 760-602-2741 Kathleen Lawrence@carlsbadca eov ] j Greg Ryan 1. 760-602-4663 Gregorv Rvan@carlsbadca fiov 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov f 1 Linda Ontiveros I „j 760-602-2773 Linda Ontiveros®carlsbadca gov r ~l Cindy Wong —760-602-4662 Cvnthia Wong@carlsbadca gov r 1 Dominic Fieri 1 760-602-4664 Dommic Fieri@carlsbadca gov Remarks: 4 ^ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www carlsbadca gov ENGINEERING Plan Check for CB 12-1226 Date 08/03/12 Project Address 2505 PALOMAR AIRPORD RD Project Description Tl CHIPOTLE GRILL APN 215-020-18 Valuation $117,055 ENGINEERING Contact Kathleen Lawrenco Phone 760-602-2741 Email kathleen.lawrence@carlsbadca.gov Fax 760-602-1052 • RESIDENTIAL • RESIDENTIAL ADDITION MINOR (<$20,000.00) • CARLSBAD PREMIER OUTLETS • OTHER: cell antennas [Z] TENANT IMPROVEMENT • PLAZA CAMINO REAL • COMPLETE OFFICE BUILDING OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY. KATHLEEN LAWRENCE REMARKS. DATE 08/06/12 Notification of Engmeering APPROVAL has been sent to via J on Page 1 of 1 E-36 REV 4/30/11 ^ CITY OF n PLAN CHECK REVIEW TRANSMITTAL Community & Economic, Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 10/25/12 PROJECT NAME: PLAN CHECK NO: CB121226 SET#: PROJECT ID: ADDRESS: 2505 PALOMAR AIRPORT RD APN: 213-020-18-00 ^ This plan check review is complete and has been APPROVED by the PLANNING Division. ^ By: GINA RUIZ A Final Inspection by the PLANNING Division is required • Yes ^ No I I This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. ' Plan Check APPROVAL has been sent to: bgray@ddg.bz You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clanfications on the attached checklist please contact the following reviewer as marked x^l* '^WNNINGt''' ,,r.f r •-.•."-760-602^610'*;' ENGINEERING 760-602-2750 > —t ' FIRE PREVENTION ^ 760^602-4665 .* - 1 1 Chris Sexton 760-602-4624 Chris SextonOcarlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 Greg Ryan 760-602-4663 Gregorv Rvan@carlsbadca gov X Gina Ruiz 760-602-4675 Gma RuizOcarlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • I 1 Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca gov Remarks: ^ PLANNING DIVISION Peveloament Services ^.£f> BUILDING PLAN CHECK Planning Division ^^CiPYOF REVIEW CHECKLIST leSS Faraday Avenue CARLSBAD P-28 (760) 602-4610 www carlsbadca gov Plan Check No CB121226 Address 2505 Palomar Airport Rd Date 10/25/12 Review #3 Planner GINARUIZ Phone (760) 602- 4675 ^ APN 213-020-18-00 Type of Project & Use H Net Project Density DU/AC Zoning C-M General Plan Pi Facilities Management Zone 5 CFD (in/out) # Date of participation Remaining net dev acres (For non-residential development Type of land use created by this permit ) REVIEW # 12 3 Legend ^ Item Complete (Q) Item Incomplete - Needs your action 13 • • Environmental Review Required YES • NO |EI TYPE DATE OF COMPLETION ___ Compliance with conditions of approval"? If not, state conditions which require action Conditions of Approval • • Discretionary Action Required YES • NO TYPE APPROVAL/RESO NO DATE PROJECT NO OTHER RELATED CASES Compliance with conditions or approval If not, state conditions which require action Conditions of Approval J D D Coastal Zone Assessment/Compliance Project site located in Coastal Zone"? YES • NO El CA Coastal Commission Authority"? YES • NO JEi If California Coastal Commission Authority Contact them at - 7575 Metropolitan Dnve, Suite 103, San Diego, CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) • • Habitat Management Plan Data Entry Completed"? YES • NO Kl If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Q Q Inclusionary Housing Fee required YES O NO Kl (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed"? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') • • Housing Tracking Form (form P-20) completed YES • NO • N/A K p-28 Page 1 of 2 07/11 Site Plan K • • City Council Policy 44 - Neighborhood Architectural Design Guidelines • • 1 Applicability YES • NO ^ • • 2 Project complies YES • NOQ • • Zoning N/A 1 Setbacks Front Interior Side Street Side Rear Top of slope Required Required Required Required Required Shown Shown Shown Shown Shown • • 2 Accessory structure setbacks N/A Front Required Intenor Side Required Street Side Required. Rear Required Structure separation Required Shown Shown Shown Shown Shown • • 3 Lot Coverage N/A Required Shown Screening of Equipment Required YES Shown REEVIEWED WITH V L -CONFIRMED TO BE ADEQUATE SCREENING • • 5 Parking Spaces Required AS PER APPRVD PLN Shown N/A (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Q)0 ^ Additional Comments #1 IS THERE AN EXISTING PARAPET TO SCREEN THE NEW RQQ^ MOUNTED EQUIPMENT AS SHOWN ON SHEET MIOPIAS THIS IS A HIGHLY VISIBLE INTERSECTION. AND PER THE CONDITIONS OF APPROVAL (SEE ATTACHMENT). PLEASE ADD SECTIONS SHOWING HOW THE PROPOSED ROOF MOUNTED EQUIPMENT WILL BE SCREENED FROM VIEW FROM STREETS WITHIN 500 F-EET^ PLANCHECK #2 THE DETAILS FOR THE PACKAG'ED ROOFTOP UNITS RTU 1 & RTU 2 AS SHOWN ON SHBBT A150 AND STATED ON SHEET M200 ARE MISSING FROM THE PLANS THIS tfOF^MATION IS NEEDED IN ORDER TO DETERMINE IF THE EQUIPMENT IS HIGHER/LOWER THAN THE PARAPET #2 PLEASE CALL OUT THE HEIGHT QF THE PARAPET IMMEDIATELY ADJACENT TO THE UNITS (Fy\CING PALOMAR AIRPORT RD) AS ONLY THE HEIGHT OF THE PARAPET THAT IS CALLED OUT THAT FACES THE PARKING LOT ON SHEET A150 #3 PLEASE OUTLINE THE PROPOSED ROOFTOP UNITS QN THE EXTERIOR ELEVATIONS SHEET AgOO- OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER GINA RUIZ DATE 10/25/12 3-1cnon B410A PKGD Unitar7 Gas/Electric Rooftop (Y4C) Items RTU-2 (This Item IS not 'In Job') 7/30/2010 2 05 40 PM Job01 CONTROL BOX SECTION ACCESS PANEL GAS CONNECTION (SEE NOTE 2) EVAPORATOR SECTION ACCESS PANEL INDOOR TOP PANEL CONDENSATE (SEE NOTE 1 OUTDOOR TOP PANEL CONDENSER FAN CONDENSER COIL CONDENSER COIL SIDE COMPRESSOR ACCESS PANEL POWER WIRE (SEE NOTE 3) THROUGH THE BASE CONDENSATE - 4 3/16" 52 5/16 50 7/8" 17 1/2' 32 1/8" RETURN 17 1/2' 33" SUPPLY -27 9/16 • 4 11/16" - 5 5/8' -51 13/16 - • THROUGHT BASE GAS -THROUGHT THE BASE ELECTRICAL 2 9/16" 6 3/8 BOTTOM OF UNI T DOWN FLOW 32 1/4' 3E I 1, 9 3/8' -"•191/4'-* SUPPLY 16 11/16" RETURN -mr 4 1/4" -27 9/16"- -99 11/16"- 32 1/4' 4 3/4 CONDENSATE DRAIN (SEE NOTE 4) / HORIZONTAL FLOW SIDE DIMENSION DRAWING NOTES 1 ALTERNATE CONDENDATE DRAIN CONNECTION 3/4 - 14NPTDIA HOLE 2 1/2' NPT GAS CONNECTION (80 mbh, 120 mbh), 3/4 NPT GAS CONNECTION (ISOmbh, 200mbh, 250mbh) 3 UNIT POWER WIRE 1 3/8 DIA HOLE COIL- SERVICE SIDE - 62 1/4 -63 3/16'- CONDENSER COIL SIDE DIMENSION DRAWING HORIZONTAL AIR FLOW -3/16" TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST Page 1 PLAN CHECK PLAN CHECK Community & Economic CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL ^ Carlsbad CA 92008 '^^^ www carlsbadca gov o DATE: 11/19/12 PROJECT NAME: chipotle PROJECT ID: PLAN CHECK NO: Cbl21226 SET#: ADDRESS: 2S05 PAR Bldg 4 Ste lOOAPN: ^ a • This plan check review is complete and has been APPROVED by the fire Dillon. By: cwong A Final Inspection by the Division is required |^ Yes • No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to:-m9ith@ddg.bz you may also have corrections from one or more of the divisions Usted below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the followmg reviewer as nnarked- PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chris Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 1 Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov X Cindy Wong 760-602-4662 Cynthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic Fieri@carisbadca gov D*** Please fill out and retum attached Fire Permit Application for Assembly occupancy. Matt from John Dungan to provide an 8 X11" approved seating plan for submittal with permit application **** ^ y **APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Carlsbad Fire Department Plan Review Requirements Category TI, COMM Date of Report 11-19-2012 Name Address BRETT GRAY STE 304 8826 SANTA FE DR OVERLAND PARK KS 66212 Permit # CB 121226 Job Name CHIPOTLE - 2,003 SF SHELL TO Job Address 2505 PALOMAR AIRPORT RD CBAD St 100 Reviewed by. O INSOMELJETE The item you have submitted for review is incomplete At this time, this office cannot adequately conducFTreviewTOTtete^^ review carefully all comments attachgd^,.,£lfias€^-estSMfif1he necessar3rpIanslSB/5TSpe©ificaJion^ with changes "clouded", to this officeJai;»fevieW°anaa]pproval Conditions: Cond CON0005877 [MET] c%tS?Pleas^fillI^f aiidTfeturh-i'SSc . J ohn-Dunganito7poyide^78r;X17r> ara 'man ^6r-?submfttaLwith^peHfiit-applrca^ ** APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry 11/19/2012 By cwong *Action..-AP BLDG, DEPT COPY ^ ^ CORRECTION LIST Daryl K. James & Associates, Inc 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net Checked by Daryl Kit James Date: October 24. 2012 APPLICANT: Brett Gray JURISDICTION: Carlsbad Fire Department PROJECT NAME: Chipotle PROJECT ADDRESS: 2505 Palomar Airport Road PROJECT DESCRIPTION. CB121226 2,003^ Shell to Restaurant This plan review is order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department COMMENTS AOOO Provide a Scope of Work for This Project • Model Codes Add the Following Model Code 2010 California Fire Code • Code Compliance Data 1 Revise occupancy Group to A-2 and building overall See seating shown on A003 and Compliance Data #4 5 Revise reference from Group B to Group A-2 Verify other tenant is a Group B 6 Revise Dining Area occupant load to address seating shown on A003 See Compliance Data #4 7 Revise number of exits required See seating shown on A003 and Compliance Data #4 • Deferred Submittals Add list of deferred submittals Fire Sprinkler System 2010 CFC 903 and 2010 NFPA 13 Fire Alarm System 2010 CFC 907 including CFC 907 2 sections specific to applicable occupancy groups and 2010 NFPA 72 UL300 Commercial Hood & Duct Extinguishing System - 2010 CFC Section 904 UL300 hood & duct extinguishing system shall be designed in accordance with CFC Sections 904 11, 609 1, 609 2 and 2002 NFPA 17A UL 300 hood & duct exhaust and extinguishing system plans to include, but not be limited to, manufacturer's Installation & service manual, plans providing designed details and dimensions of appliances, height of nozzles above cooking surfaces Hood & duct extinguishing system in accordance with manufacturer's Installation & Service Manual • Sheet Index Add Sheets S2 and P300 • A001 Add Item # for a type "K" fire extinguisher Add Item # for an occupant load sign Add Item # 35 2 This is shown on A130 Page 2 of 2 • A003 Denote the occupancy group for the adjacent suite • A117 Door Hardware Schedule Door #2 Justify the use of a key-operated locking device The locking arrangement is not permitted on any door other than the mam exit CBC 1008 1 9 3 Provide panic hardware on Door #2 CBC 1008 1 10 Door Notes Note 2 Revise to read, All Door Hardware Will Comply With 2010 CBC Section 1008 1 9 NFPA 101 is not adopted in the State of California Note 4 Revise to read. This Door to Remain Unlocked When Building is Occupied CBC 1008 1 9 3 •A120 Specify if there will be decorative materials If applicable, provide specifications and California State Fire Marshal listings as well as other acceptance critena for flame spread and smoke developed index for decorative matenals CFC 807 No decorative materials. •A130 Denote the location of an occupant load sign in dining area CBC 1004 3 Denote the location of a Type "K" Fire Extinguisher •A140 It appears that partial lighting locations are provided Coordinate means of egress illumination with Sheet E100 Add emergency lights in dining area • M300 Remove Fire Suppression System Schematic See Deferred Submittals on Sheet AOOO Provide an air balance schedule for each kitchen hood CMC 511 3 Be sure to descnbe the construction matenals (combustible, limited combustible, or non-combustible) used adjacent to the hood and duct CMC 507 2 •EIOO It appears that partial lighting locations are provided Add means of egress illumination in dining area Coordinate means of egress illumination with Sheet Al 40 Plan Notes Add the following note Means of egress illumination level shall be not less than 1-foot candle at the walking surface and equipped with minimum 90-minute battery backup CBC 1006 2 & 1006 3 Page 1 of 3 BLDG. DEPT COPY CORRECTION LIST 2 Daryl K James & Associates, Inc 205 Colina Terrace Vista, CA 92084 T (760)724-7001 Email: kitfire@sbcglobal.net Checked by Daryl Kit James Date: September 4. 2012 APPLICANT. Brett Gray JURISDICTION. Carlsbad Fire Department PROJECT NAME: Chipotle PROJECT ADDRESS: 2505 Palomar Airport Road PROJECT DESCRIPTION. CB121226 2,003t^ Shell to Restaurant This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department The Items below require correction, clarification or additional information before this plan check can be approved for permit issuance INSTRUCTIONS • To expedite the recheck process, please note on this list (or copy) the response to each correction item and where it has been addressed, i e sheet number, note number, detail number, legend number, etc Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates • PLEASE SEND OR DlLlVER REVTSED PLANS DIRECTLY TO: DARYL K. JAMES 205 COLINA TERRACE VISTA, CA 92084 • Please direct any questions regarding this review directly to: Daryl K James 760-724-7001 or kitfire@sbcglobal.net COMMENTS AOOO • Provide a Scope of Work for This Project • Model Codes Add the Following Model Code 2010 California Fire Code Code Compliance Data 1 Revise occupancy Group to A-2 and building overall See seating shown on A003 and Compliance Data #4 5. Revise reference from Group B to Group A-2 Verify other tenant is a Group B 6 Revise Dining Area occupant load to address seating shown on A003 See Compliance Data #4 7 Revise number of exits required See seating shown on A003 and Compliance Data #4 Deferred Submittals Add list of deferred submittals Fire Sprinkler System 2010 CFC 903 and 2010 NFPA 13 Page 2 of 3 Fire Alarm System 2010 CFC 907 includmg CFC 907 2 sections specific to applicable occupancy groups and 2010 NFPA 72 UL300 Commercial Hood & Duct Extinguishing System - 2010 CFC Section 904. UL300 hood & duct extinguishing system shall be designed in accordance with CFC Sections 904 11, 609 1, 609 2 and 2002 NFPA 17A UL 300 hood & duct exhaust and extinguishing system plans to include, but not be limited to, manufacturer's Installation & service manual, plans providing designed details and dimensions of appliances, height of nozzles above cooking surfaces Hood & duct extinguishing system in accordance with manufacturer's Installation & Service Manual •Sheet Index Add Sheets S2 and P300 A001 Add Item # for a type "K" fire extinguisher Add Item # for an occupant load sign Add Item # 35 2 This is shown on A130. A103 Denote the occupancy group for the adjacent suite. Specify is separated by a rated demising wall • A117 Door Hardware Schedule Door #2 Justify the use of a key-operated locking device The locking arrangement is not permitted on any door other than the mam exit CBC 1008 1 9 3 PH provided Provide panic hardware on Door #2 CBC 1008 1 10 Door Notes Note 2 Revise to read. All Door Hardware Will Comply With 2010 CBC Section 1008 1 9. NFPA 101 is not adopted m the State of California Note 4 Revise to read, This Door to Remain Unlocked When Building is Occupied CBC 1008 1 9.3 A120 Specify if there will be decorative materials. If applicable, provide specifications and California State Fire Marshal listings as well as other acceptance criteria for flame spread and smoke developed index for decorative materials CFC 807 NO RESPONSE PROVIDED • A130 Denote the location of an occupant load sign in dining area CBC 1004 3 Denote the location of a Type "K" Fire Extinguisher •A140 It appears that partial lighting locations are provided Coordinate means of egress illumination with Sheet EIOO ^Add emergency lights in dining area • M300 Remove Fire Suppression System Schematic See Deferred Submittals on Sheet AOOO Provide an air balance schedule for each kitchen hood CMC 511 3 Be sure to descnbe the construction materials (combustible, limited combustible, or non-combustible) used adjacent to the hood and duct CMC 507 2 EIOO it appears that partial lighting locations are provided •Add means of egress illumination in dining area Page 3 of 3 • Coordinate means of egress illumination with Sheet A140 Plan Notes Add the following note Means of egress illumination level shall be not less than 1-foot candle at the walking surface and equipped with minimum 90-minute battery backup CBC 1006 2 & 1006 3 BLDG. DEPT COPY ^ ""^^ CORRECTION UST Daryl K James & Associates, Inc Checked by: Darvl Kit James 205 Colina Terrace Date: July 3, 2012 Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Brett Gray JURISDICTION- Carlsbad Fire Department PROJECT NAME: Chipotle PROJECT ADDRESS: 2505 Palomar Airport Road PROJECT DESCRIPTION: CB121226 2,0030] Shell to Restaurant This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department The Items below require correction, clarification or additional information before this plan check can be approved for permit issuance INSTRUCTIONS • To expedite the recheck process, please note on this list (or copy) the response to each correction item and where it has been addressed, i e sheet number, note number, detail number, legend number, etc Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates ' PLEASE SEND^OR DELIVER REVISED PLANS WITH ESGIL COMMENTS DIRECTLY TO: DARYLK JAMES _ rr 205 COLINA TERRACE VISTA, CA 92084 • Please direct any questions regarding this review directly to: Daryl K. James 760-724-7001 or kitfire@sbcglobal.net COMMENTS AOOO Provide a Scope of Work for This Project Model Codes Add the Following Model Code 2010 California Fire Code Code Compliance Data 1 Revise occupancy Group to A-2 and building overall See seating shown on A003 and Compliance Data #4 5 Revise reference from Group B to Group A-2 Venfy other tenant is a Group B 6 Revise Dining Area occupant load to address seating shown on A003 See Compliance Data #4 7 Revise number of exits required See seating shown on A003 and Compliance Data #4 Deferred Submittals Add list of deferred submittals Fire Spnnkler System 2010 CFC 903 and 2010 NFPA 13 Fire Alarm System 2010 CFC 907 including CFC 907 2 sections specific to applicable occupancy groups and 2010 NFPA 72 Page 2 of 2 UL300 Commercial Hood & Duct Extinguishing System - 2010 CFC Section 904 UL300 hood & duct extinguishing system shall be designed in accordance with CFC Sections 904 11, 609 1, 609 2 and 2002 NFPA 17A UL 300 hood & duct exhaust and extinguishing system plans to include, but not be limited to, manufacturer's Installation & service manual, plans providing designed details and dimensions of appliances, height of nozzles above cooking surfaces Hood & duct extinguishing system in accordance with manufacturer's Installation & Service Manual Sheet Index Add Sheets S2 and P300 A101 Add Item # for a type "K" fire extinguisher Add Item # for an occupant load sign Add Item # 35 2 This is shown on A130 A103 Denote the occupancy group for the adjacent suite A117 Door Hardware Schedule Door #2 Justify the use of a key-operated locking device The locking arrangement is not permitted on any door other than the mam exit CBC 1008 1 9 3 Provide panic hardware on Door #2 CBC 1008 1 10 Door Notes Note 2 Revise to read. All Door Hardware Will Comply With 2010 CBC Section 1008 1 9 NFPA 101 is not adopted in the State of California Note 4 Revise to read. This Door to Remain Unlocked When Building is Occupied CBC 1008 1 9 3 A120 Specify if there will be decorative matenals If applicable, provide specifications and California State Fire Marshal listings as well as other acceptance cnteria for flame spread and smoke developed index for decorative matenals CFC 807 A130 Denote the location of an occupant load sign in dining area CBC 1004 3 Denote the location of a Type "K" Fire Extinguisher A140 It appears that partial lighting locations are provided Coordinate means of egress illumination with Sheet EIOO Add emergency lights in dining area M300 Remove Fire Suppression System Schematic See Deferred Submittals on Sheet AOOO Provide an air balance schedule for each kitchen hood CMC 511 3 Be sure to descnbe the construction matenals (combustible, limited combustible, or non-combustible) used adjacent to the hood and duct CMC 507 2 EIOO It appears that partial lighting locations are provided Add means of egress illumination in dining area Coordinate means of egress illumination with Sheet A140 Plan Notes Add the following note Means of egress illumination level shall be not less than 1-foot candle at the walking surface and equipped with minimum 90-minute battery backup CBC 1006 2 & 1006 3 STRUCTURAL CALCULATIONS Chipotle Carlsbad Store No. 1660 2505 Palomar Airport Road Building 4 Suite 100 Carlsbad, CA 92011 JOB NUMBER: 2012-0989 PROJECT ENGR. Rod Sommer, P.E. Norton 85 Schmidt Consulting Engineers, LLC PROJECT ARCH: John M. Dungan, Architect DATE: June 22, 2012 Conterminous 48 States 2009 hitemational Buildmg Code Latitude = 33 1279 Longitude = -117 27039999999998 Spectral Response Accelerations Ss and SI Ss and SI = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.01 deg grid spacing Penod Sa (sec) (g) 0.2 1.142 (Ss, Site Class B) 1.0 0.432 (SI, Site Class B) < .7^ Conterminous 48 States 2009 International Building Code Latitude = 33.1279 Longitude = -117 27039999999998 Spectral Response Accelerations SMs and SMI SMs = Fa X Ss and SMI = Fv x SI Site Class D - Fa = 1.043 ,Fv = 1 568 Penod Sa (sec) (g) 0.2 1.191 (SMs, Site Class D) 1 0 0.678 (SMI, Site Class D) -ct, KAvj V (i-Au- ere?) u \ -(VKCTOT \'>>,>>A ^ 13 ?:>, 2,; (fl^^^O) 1?^. Conterminous 48 States 2009 International Buildmg Code Latitude = 33 1279 Longitude = -117 27039999999998 Design Spectral Response Accelerations SDs and SDI SDs = 2/3 X SMs and SDI = 2/3 x SMI Site Class D - Fa = 1 043 ,Fv = 1 568 Penod Sa (sec) (g) 0 2 0.794 (SDs, Site Class D) 1.0 0.452 (SDI, Site Class D) S^^y^^i- t>t5^<iSA3 c^Ku^oflM t5 NORTON & SCHMIDT Consulting Engineers, LLC 311 E 11th Avenue North Kansas City, MO 64116 Phone (816)421-4232 Fax (816)421-1956 Project Job No Calculated by Checked by Date Sheet No ^ of .•sir 1_ life ^ 5^ rp-rT"Cu7d€T~ i - I ! PROJECT NO SHEET NO 3 OF 3 PROJECT NAME MADE BY DATE CHECKED BY DATE 2009 International Building Code (ASCE 7-05) WIND - INPUT VALUES Wind Speed Importance Factor Wind Directionality Factor Exposure Exp B E= 1 0 Exp C E=2 0 Exp D E=3 0 Eave height Building width (least horizontal dimension) Internal Pressure Coefficients GCpi V = 85 mph I = 1 00 Kd = 0 85 Exp E = 20 h = 16 7 feet b = 54 67 feet GCpi = 0 18 GCpi2 = -0 18 Enclosed Building Low-Rise Building < 60' Roof slope < 7 degrees (Note To use the Alternate Basic Load Combinations, apply an omega factor of 1 3 to the wind loads) Top of Parapet height hp = 22 00 feet CALCULATED VALUES Velocity Pressure q = 13 7 Edge strips End zones Velocity pressure exposure coefficient Mam Wind Force Pressure Resisting System Coefficient psf a = 55 ft 2a=109 ft Kz = 0 87 Velocity Pressure at top of parapet qp = 14 5 psf Wind Pressure (Mm combined pressure>=10 psf) Neqative internal pressure End Zone = 2 a = = 10 9 fl Intenor Zone Wmdward Wall GCp = 04 Pw = = q(GCp -GCpi2) Pw = 79 Leeward Wall GCp = -0 29 Pw = = q (GCp -GCpi2) Pw = -1 5 Roof GCp = -0 69 Pw = = q (GCp -GCpi2) Pw = -7 0 Enij Zone Windward Wall GCpi2) Leeward Wall GCp = 0 61 Pw = = q (GCp -GCpi2) Pw = 108 Roof GCp = -0 43 Pw = = q (GCp -GCpi2) Pw = -3 4 GCp = -1 07 Pw = = q(GCp -GCpi2) Pw = -12 1 Positive internal pressure Intenor Zone Wmdward Wall GCD = 04 Pw = = 0 (GCo -GCD\) Pw = 30 Leeward Wall GCp = -0 29 Pw = = q(GCp-GCpi) Pw = -6 4 Roof GCp = -0 69 Pw = = q(GCp-GCpi) Pw = -11 9 End Zone Wmdward Wall GCpi) Leeward Wall GCp = 0 61 Pw = = q (GCp -GCpi) Pw = 59 Roof GCp = -0 43 Pw = = q (GCp -GCpi) Pw = -8 3 Roof GCp = -1 07 Pw = = q (GCp -GCpi) Pw = -171 Parapet pressure Wmdard Parapet GCpn = = 1 5 Pp = = qp GCpn Pp = 21 7 Leeward Parapet GCpn •= = -1 0 Pp = = qp GCpn Pp = -14 5 PROJECT NO SHEET NO OF^ PROJECT NAME MADE BY DATE CHECKED BY DATE 2C06 IfeC V = 850 mph Components and Cladding h = 167 ft Pressure Coefficients b = 54 7 ft Wind Pressure / Suction P^ / S^,, Neqative internal pressure Interior Zone Wall Trib > 500 SF Tnb = 200 SF Tnb = 50 SF Tnb = 20 SF Tnb < 10 SF Roof Trib>100SF Tnb = 50 SF Tnb = 20 SF Tnb< 10SF Parapet (Case A) Parapet (Case B) (Mm pressure/suction = 10 psf) Edge Stnps a = 55 Wall Tnb > 500 SF Tnb = 200 SF Tnb = 50 SF Tnb = 20 SF Tnb < 10 SF Roof Trib>100SF Tnb = 50 SF Tnb = 20 SF Trib< 10SF Parapet (Case A) Parapet (Case B) Positive intemal pressure Interior Zone Wall Tnb > 500 SF Tnb = 200 SF Tnb = 50 SF Tnb = 20 SF Tnb< 10SF Roof Trib>100SF Tnb = 50 SF Tnb = 20 SF Tnb< 10SF Parapet (Case A) Parapet (Case B) Edge Stnps a = 5 5 Wall Tnb > 500 SF Tnb = 200 SF Tnb = 50 SF Tnb = 20 SF Trib<10SF Roof Trib>100SF Tnb = 50 SF Tnb = 20 SF Trib< 10SF Parapet (Case A) Parapet (Case B) GCp = 0 70 9 Pw q (GCp -GCpi2) Pw = 11 1 GCo = 0 76 9 Pw a ^GCP -GCPI2) Pw = 11 8 GCo 0 87 9 Pw = a (GCP -GCDI2^ Pw = 13 1 GCo = 0 95 9 Pw = 0(GCP -GCDI2) Pw = 14 1 GCo = 1 0- 9 Pw = a (GCP -GCDI21 Pw = 14 7 GCo = 0 20 Sw = a(GCP -GCDI2^ Sw = 52 GCo = 0 22 Sw = 0 (GCP -GCDI2> Sw = 55 GCP = 0 27 Sw = 0 (GCD -GCDI2) Sw = 6 1 GCP = 0 30 Sw = 0 fGCo -GCDi2^ Sw = 66 GCP 0 82 0 9 -H 1 1 PD QD (GCD -- GCPI2^ PP = 29 2 GCp = 1 74 9 Sp = qp (GCp -- GCpi2) Sp = 25 3 feet GCo 07 9 Pw a (GCD -GCPI2^ Pw = 11 1 GCP = 0 76 9 Pw = q (GCp -GCpi2) Pw = 11 8 GCp = 0 87 9 Pw = a (GCD -GCPI2^ Pw = 13 1 GCP = 0 95 9 Pw = a (GCD -GCPI2^ Pw = 14 1 GCP = 1 0 9 Pw = a (GCD -GCPI2^ Pw = 14 7 GCP = 0 20 Sw = a(GCD -GCPI2) Sw = 52 GCP = 0 22 Sw = 0(GCD -GCDI2) Sw = 5 5 GCD = 0 27 Sw = a (GCD -GCDI2) Sw = 6 1 GCp = 0 30 Sw = q (GCp -GCpi2) Sw = 66 GCP 0 82 0 9 + 1 1 PD = QD (GCD -- GCDI2^ PD = 29 2 GCp = 1 87 9 Sp qp (GCp -- GCpi2) Sp = 27 0 GCP -0 80 9 Pw a(GCD -GCDI) Pw = -12 3 GCP = -0 87 9 Pw ---a(GCD -GCDO Pw = -13 1 GCP = -0 98 9 Pw = 0(GCD -GCPI) Pw = -14 5 GCp = -1 05 9 Pw q(GCp -GCpi) Pw = -15 4 GCP = -1 1 9 Pw = a(GCP -GCPI) Pw = -16 0 GCo -0 9 Sw a(GCD -GCDI) Sw = -14 7 GCP = -0 93 Sw = a (GCP -GCDI) Sw = -152 GCP = -0 98 Sw a (GCP -GCDII Sw = -15 8 GCP = -1 0 Sw = a (GCD -GCPII Sw = -16 1 GCP = 0 82 0 9 + 1 1 PD QD (GCD -- GCPI) PP = 24 0 GCp = 1 74 9 Sp = qp (GCp -- GCpi) Sp = 20 1 feet GCP — -0 80 9 Pw = a (GCD -GCPI) Pw = -12 3 GCP = -0 92 9 Pw = a (GCo -GCDI) Pw = -13 8 GCD .= -1 15 9 Pw = a (GCD -GCPI) Pw = -16 6 GCP = -13 9 Pw Cl (GCD -GCPI) Pw = -18 4 GCp = -14 9 Pw q (GCp -GCpi) Pw = -19 7 GCD = -1 1 Sw 0(GCD -GCDI) Sw = -17 5 GCD -1 3 Sw = Cl (GCD -GCDI) Sw = -20 2 GCP = -1 6 Sw = a(GCD -GCPI) Sw = -24 3 GCD -1 8 Sw a (GCD -GCPI) Sw = -27 0 GCP = 0 82 0 9 + 1 1 PD = OP (GCP -- GCPI) PP = 24 0 GCp = 1 87 9 Sp = qp (GCp -- GCpi) Sp = 21 7 NORTON & SCHMIDT Consulting Engineers, LLC 311 E 11th Avenue North Kansas City, MO 64116 Phone (816) 421-4232 Fax (816)421-1956 Project Job No Calculated by Checked by Date Sheet No of ^ , - /. p /5 -i- -1—4 —'. , NORTON & SCHMIDT Consulting Engineers, LLC 311 E 11th Avenue North Kansas City, MO 64116 Phone (816)421-4232 Fax (816)421-1956 Project Job No Calculated by Checked by Date Sheet No <b of % " '''" 'Jt\^,f> T^i^ ----- -. - -I5.V 4- NORTON & SCHMIDT Consulting Engineers, LLC 311 E nth Avenue North Kansas City, MO 64116 Phone (816) 421-4232 Fax (816)421-1956 Project Job No Calculated by Checked by Date Sheet No ^7 of - h )4-^7- j|Zj> ^) 4-^ i - -i- 1 -1 1 I -1—1-- T""T NORTON & SCHMIDT Consulting Engineers, LLC 311 E 11th Avenue North Kansas City, MO 64116 Phone (816)421-4232 Fax (816)421-1956 Project Job No Calculated by Checked by Date Sheet No ^ of V i i r I : I HDDD ND •<DBE:L LENGTH MPX CDDKiNG TEMP rXhALiST PI FNUM SUPPLY PLENUM HDOD CDNSTRUCTIDN HDDD CCNFIG SWIT HDDD ND •<DBE:L LENGTH MPX CDDKiNG TEMP TDT4L EXH CFM ?iSERCS) TOTAL SUP CFM RISER(S) HDOD CDNSTRUCTIDN END TD END ROW DUANTITV LOCATION HDDD ND •<DBE:L LENGTH MPX CDDKiNG TEMP TDT4L EXH CFM VIDTH LENC Din CFM S P TOTAL SUP CFM WIDTH LENG DJA CFM S P HDOD CDNSTRUCTIDN END TD END ROW DUANTITV LOCATION 1 542-4 ND-E-PSP-F a OOD '50 Deg .800 jO 17 1800 -0 98! '155 430 SS Where Exposed ALDNE ALONE 1 542-4 ND-E-PSP-F a OOD '50 Deg .800 '155 430 SS Where Exposed ALDNE ALONE 2 VHB-ND •1 9 00 700 <75 a-' 475 -0 056' 0 304 SS 100/ ALONE ALONE I FAN 1 LIGHT FRONT RIGHT FACE 2 VHB-ND •1 9 00 700 <75 0 304 SS 100/ ALONE ALONE I FAN 1 LIGHT FRONT RIGHT FACE I LA^ER OF [NSULATIDN FfCrORY INSTALLED IN 3 00 ENS SfANDlFF MEETS : REQliiHEMCNTS CLEARANCE TO COMBUSTIBLE SURFACES HDDD NO FILTERS) LJDHTCS) UTILITY CA3INET(S) FIRE SYSTEM PIPING HDDD 4flNGINC WGHT HDDD NO TYPE OTT HEIGHT LENGTH OTY TYPE WIRE CUARI LOCATIDN FIRE SYSTEM ELECTRICAL SWITCHES FIRE SYSTEM PIPING HDDD 4flNGINC WGHT HDDD NO TYPE OTT HEIGHT LENGTH OTY TYPE WIRE CUARI LOCATIDN TYPE SIZE COBEL » QUANTITY FIRE SYSTEM PIPING HDDD 4flNGINC WGHT 1 Captraie Solo Filter vri 1 i& 5 'rcandescent Light Fixt ND RiBht 30 E0I'0ie3-OS J Light I Fch I Ct'-'cr YES 548 LSS 1 Captraie Solo Filter vri 4 16 2D 5 'rcandescent Light Fixt ND RiBht 30 E0I'0ie3-OS J Light I Fch I Ct'-'cr YES 548 LSS 2 2 incQhdescert Light Fixt ND ND 217 LBS 2 2 incQhdescert Light Fixt ND ND 217 LBS HOOJ) OPTIONS HDDD ND DPTIDN 1 FIELI WRAPPER 19 00 High Front Right LEFT END STANDOFF 3 Wioie 54' LonB insUci*ed RIGHT QUARTER END PANEL 23" Top Width 0 Bottom Width 23' high 430 SS INSULATION FDR BACK DF HOOD 2 FIELI WRAPPER 6 00 High Front Left Right PERFORATED SUPPLY PLENUVfS) HDDD ND PDS LENGTH WIDTH HEIGHT TYPE RISERCS) HDDD ND PDS LENGTH WIDTH HEIGHT TYPE WIDTH LENG DIA CFM SP 1 Front 111 12 5 MUA .a 16 562 0 25B MUA 10 16 562 0 258 UL Llst^lW: cert Light Fixture-High Terp Assenloly Q Q -4 9 00 Non/4 9 00 DD - 1 LAYER DF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFr MEETS 0 [NCH REflUIREHENTS FDR CLCARANCE TO CGMBUSFIBLE: SUHFACeS U,7^ UJ. Listed Incandescent Light Fhtture-HIgh Tenp Assenbly o - 8 a.ao'Namya aaa c PLAN VIEW IT IS THE RESPONSIBlLITf QF THE ACCMirECT/OVNER TO ENSURE THAT THE HDDD CLEARANCE FROM LIMITED-CDMBUSTtBLE -AND CDHBUSTIBLE MATERIALS IS iN COMPLIANCE VITH LCXAL CODE REQUIREMENTS 4' 9 00 LONG - Hood ^2 542^yH3-ND INCANDESCENT LIQHT FIXTURE-HIGH TEW ASSEMBLY INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE <L55 FIXTURE) EXHAUST RISER - HANGING ANGLE - CAPTIVE-AIRE HOaDS ARE BUiLT IN COMPLIAWCE WITH UL 710 AND NFPA 96 AND ARE RECOGNIZED BY ONE OR MORE OF THE FOLLOWING ETL SANITATION LISTED ETL LISTED FILEtt 3054804-001 'NSULATION FACTORY WredNAL SFANOOFF MECTS 0 INCH REQUIREMENTS FDR ' CLEARANCE TO COMBUSTIBLE SURFACES ]T (S THE RESPONSiaiLnr CF THE APCHITECT/DWWER IQ EKSURE THAT THE HOQI CLEARANCE FROM LIMITEB-COMBUSTIBLE - AND CDMBUSTiSLE MATERIALS iS iN CDMPLiANCE WITH LOCAL CODE RECU'REMEMS RIGHT OLARTER END PANEL - 80 AFF TYP SECTION VIEW - MODEL E4.24VHB-ND PUN VIEW - Hood I1 8' 0 00 LONG 5424ND-2-PSP-F INCANSESCEMT LIGHT FIXTLB^-HIGH TEMP ASSEMBLY INCLUDES CLEAR THERMAL AND SHXK RESISTANT GLOBE CLS5 FIxrL«E> -ATTACHING PLATES ^FCTION VIEW - MODEL 5424ND-2-PSP-F ND—2 Series wilh P5P Accessory Specification The NS-E series hood *i-th PSP accessory is a conpensQ-ting canopy hood system roted for oU types cf cooking equipnent The hood shall hove the size shape and perfornance specified on drawings Construction shall be type 430 stainless steel with Q tt3 or tt4 polish where exposed Individual conponent construction shall be detennined hy ihe nanuFacto-rer end ETL Construction shall be dependent on the structural application to nininize distortion and other defects AU seans Joints and penetrations of the hood enclosure to the lower outernost perineter tl-iat directs and captures grease-laden vapor and exhaust gases shall have o tlquid-tight continuous external weld in accordance with NFPA 96 Hood shall be waU type with Fully welded 10 gauge corner hanging angles Corner hang'^S angles have a 625 ^ ' 500 slot pre-puncVied at the foctory ollowJng hanging rods to be used for quick ond safe installations Honging rod and connect is provided by and installed by others Ventaator shall be furnished with UL classified oluninun baffle filters supplied In size and quantity cs required by ventilator The filters shall extend the full length of the hood and the filler panels snnlt not be nore than & m width The inood nanufoctwrer shall supply conplete conputer generated submittal drawings Including hood section viewfs) and hood plon viewCs) These drawings rtust be cvailoble to the engineer architect and owner for their use In construction operation and naintenance Exhaust duct collar to be 4' high with 1' flange Duct sizes CFM and static pressure requirements shall be as shown on drawings Static pressure requirenents shall be precise and accurate, oir velocity and votune infarnntion shati be accurate within 1-ft increnents along the length of the ventilator UJ_ Ircondescent light fixtures and globes shall be irstalled and pre-wired to a junction box The light fixtures shall be installed with Q naxlnun of 4 0 spacmg an center and allow up to a IQD watt stondard Ught bulb Tne hood shall l^ave - A double wall insula+ed front to elinnate condensation and mcreose rigidity The insulation sholt neve a flexurat rodulus of 475 El neet UL 181 requirenerts and be m accordorce wtth NFPA 9QA and goB - An integral front baffle to direct grease laden vapors toward the exhaust filter bank - A bwllt-in wiring chase provided for outlets and electrical controls on the hood face and shall not penetrote the capture area or require an external choseway - Low velocity "ake-up air Cup to 50/> provided trrough front and side plenuns <PSP accessory) - A renovafale grease cup for easy cleontng Tre hood shQti be CTL Listed as Cxnaust Hood Witlnout Exhaust Damper' ETL Sanita-'ion Listed end built in accordance with NFPA 96 The rood shall be listed for 450 T CQo!<ing surfaces at 150 CFM/ft 600 F coDi<irg surfaces at 200 CFH/ft Qnd 700 T cooking sjrfaces,^^|5Q CFM/ft REVISIONS III <: m (/) _i <r u • I f u <E U <r _J Q: <r u DATE 8/24/2012 DWG # 1616062 SCALE 3/4" = 1 MASTER DRAWING REVISIONS FAN UNIT NO FAN UNIT MODEL # MODEL TAG CFM ESP RPM HP VOLT FLA WEIGHT (LBS) SDNES 1 1085HFft DU85HrA FF-1 IBOD laoo 1318 0 750 I 115 130 ' 88 69 15 4 £ DR12HFA DR12HFA EF-e 150 osoo 1282 0180 1 115 20 •4084 8 3 DU30HFfl DU30HFA EF-3 475 0 30D 969 0S50 1 115 40 56 56 52 FftN #1 DUBSMFA - EXHftUST FfeN (Er-D MUA FAN INFORMATION FAN UNIT ND FAN UNIT MODEL « BLDWEH HOUSING TAG CFM ESP RPM H P CB VOLT FLA WEIGHT (LBS) SDNES 4 D76 G7 D6 KSU-I lias 0 750 1959 1500 3 2DB 4 7 333 31 26 FAN UNIT NO ACTUAL DENSITY'' INPUT BTbs •UTPUT BTUs TEMP RISE REOUIRED INPUT GAS PRESSURE GAS TVE 4 VES 69465 63908 55 deg F 7 In wc -14 in wc Natural FAN UNIT ND DPTIDN (Qty - Descr) 1 1 - Grease Box 1 - Fan Base Ceron/c Seal - For Grease Ducts 2 1 - I 12-BIlD Danper 3 1 - I 15-BDD Damper 4 1 - Inlet Pressure Gauge, 0-35 1 - AC Interlock Relay - 24VAC Coil 1 - Motorized Intake Danper <D76) 1 - Manifold Pressure Gauge -5 to 15 wo raN a? ngiPHFa - FXHAUST FAN CFF-?I DUCTWORK BETWEEN - EXHAUST RISER DN HOOD AND FAN (BY OTHERS) FEATURES FAN UNIT ND FAN UNIT TAG EXHAUST SUPPLY FAN UNIT ND FAN UNIT TAG CREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER NOTDRIZED DAMPER WALL MOUNT 1 EF-1 YES 2 EF-2 3 EF-3 4 MAU-1 YES - ROOF KDUNTEI) FANS - UL705 - SAFETY DISCONNECT - STANDARD BIRD SCREEN - SPEED CONTRGL •PTIGNS I le-BDD DAMPES NQ DN FAN WEIGHT ITEM SIZE 1 <t 1 35 LBS Curb 23 000 V X 23 0D0L x 20 000 H Vented Hinged 2 tl 2 16 LBS Cure 17 500 W X 17 500 L x 12 000 H 3 « 3 27 LBS Curb 19 500 W X 19 500 L X 20 000 H 4 « 4 50 LBS Curb 19 500 W X 52 000 L X 20 000 H Insulated FEATURES^ - RDDF MOUNTED FAKS - RESTAURANT MODEL - UL7DS Afffi UL762 - VARIABLE SPEED dDNTRDL - INTERNAL WIRING - VEATHERPR0I3F DISCONNECT - THERMAL DVERLOAD PRDTECTICffJ CSINDLE PHASE? - HIGH HEAT I3^RATIDN 30D F (1-49 C> - GREASE CLASSinCATia^ JCSTINC NDRMAL TFHPERATURF TEST EXHAUST FAN MUST DPERME CI>niNUOUSLY WHILE EXHAUSTIND AIR AT 30D F iU3 C) UNTIL ALL FAN PARTS HAVE REACHED T^CRMAL EEJUILIBRIUM AND W]THOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE DPERAriDN ABNDRMAi FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 6DQ r [316 CJ FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING 2AMAGED TO ANY EXTE^^T THAT COULD CAUSE AN UNSAFE CONDITION GREASE BOX FAN BASE CERAMIC SEAL - FOR GREASE BUCTS 20 GAUOf STEEL CDNSTRUCTIDN / ^ RODF DPENING 20 GAUGE STEEL CDNSTRUCTIDN / ^ RDDF DPENINO 13 DIMENSIONS O a <r eq C/O _i (Y -CL O LJ • Q_ U <r -J <Z u DATE 8/24/2012 DWG tt 1616062 DRAWN ,„„ .. gy JMB-40 REVISIONS lAi FAN #3 D1130HFA - EXHAUST FAN trF-3> DUCTWORK BETWEEN - EXHAUST RISER ON HDDD AND FAN (BY OTHERS) FEATURES - ROOF MOJNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - VARIABLE SPEED CCNTRQ. - INTERNAL VISING - WEATHESPREDF DiSCDNNECT - THERMAL OVERLOAD PROTECTiON (SINGLE PHASE? - HIGH HEAT OPERATION 30Q F CH9 CJ - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE T^ST EXHAUST FAN MUST CPERATE CGNTiNUOUSLY WHILE EXHAUSTING AIR AT 300 F <i45 C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EOUILJBBJUM AND VJTHOUT ANY DETERItKATiNG EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE tPERATEDN ABNORHAL FLARE-LF TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHALIST[ND BURNING GREASE VAPORS AT SOO F t316 C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN SECQMlNG DAMAGED TD ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPT ONS ! 15-3DD CAMPER FAN m D76 - HEATER <MAU-n 1 LOW CFM DIRECT FIRED HEATER BELT DRIVE 2 INTAKE HOOD WITH EZ FILTERS 3 DOWN D!SCf^AJ?GE - AJS FLOW RJGHT -> LEFT A GAS PRESSURE GAUGE 0-35 E5 D'AMETCR I/* THREAD SIZE 5 CODLiNG INTERLOCK RELAY 2<VAC COIL 12QV CONTACTS LOCKS OUT BURNER CiRCUIT WHEN AC IS ENERGIZED 6 MQTCRlZZn BAC^DBAFT DAMPER '3 X 17 FOR 076 COMPACT OlRECl F'HED HEATERS W/EXTENBED SHAFT S*aNDARB GALVANIZED CDNSTRUCTIDN 3/A REAR FLANGE TF120S ACTUATOR 'MCLUDED 7 CAS PRESSURE GAUGE -5 TQ .15 -NCHES WC 2 5 D'AMETER 1/4 IHREAD SIZE SUPPLY SIM: hEATCR INFORMAHi^ ViNTER TEMPEHAFURE = 44 F TEMP «3SE = 55f BlUs CALCULATED OFF ACTUAL AIR DCNSliY OUTPUT BTUs AT ALTITUDE [T 00 ft = 63908 INPUT BTUs AT ALTITUDE OF 00 fi = 69165 20 GAUGE STEEL CONSTRUCTION / ^ ROOF DPEMNG 2S 1/2 9 u^ I J ^ 3/16 — DISCHARGE OPENING FLEX uDNDUn ' FOR FIELD i'i RING eo EQUIPMENT CURB - ' 19 1/2 RQDF DPeNINQ 2 SMALLER THEN CURB DIMENSIDN SERVICE DISCDNNECT SWITCH FILTER - ACCESS DOOR SCREENi INTAKE ND TAG PACKAGE LOCATION SWITCHES OPTION FANS CONTROLLED ND TAG PACKAGE LOCATION LOCATIDN QUANTITY OPTION TYPE H P VOLT FLA 1 EOl 0183-05 Utility Cobiret Right Utility Cabinet Right 1 Light J '^Qr 1 Other Exhaust in Fire Lights out in Fire Supply 3 1500 208 i 7 1 EOl 0183-05 Utility Cobiret Right hood « 1 1 Light J '^Qr 1 Other Exhaust in Fire Lights out in Fire Supply 3 1500 208 i 7 Exhaust 1 0 750 115 130 i o # DATE 8/24/2012 DWG # •6i6062 SCALE 3/4 = 1 MASTER DRAWING ELECTRICAL PREWWE PACKAGE D=«WING NUMBER C!JI]0ia3-C3 oa NAME CHIPOTLE CARLSBAD #J660 JOB NUVeZR I6I6K^ CONTROL lNPnn20v!^^^LIN^^^NEUTRAL ISA BKR ST-1 OL-l • ^^wjL I^^i^^^^^^!—jg^ ((R;<aB««tb^ i-u bfH SaMt 3 PHASE soev INPUT —p U' 3 WIHE --pia' a PHASS__6uj INPUT 2 V[RE" -1 PHASE- 1 PHASE HOT C-3 DRAWN 3Y 3PhoaB - 120V/5PhaBO Pre-wire urith 1 JPficso Supply Ton 1 2(N/^Phoam E*houBt Fan Exhojal on n fro Cond t on Lights out m FTra ElBCtric Gos Vafvc Hofl«t *ith fan flmtch ond t re system COUPWCMT PARTS UST STSTEU IIBCHWKES TO M/I DOW SCMU. (NOI fOU mtUXK FIRE MJWQ BUCK Yw - yniow BLlff cr - GRAT BROWM PR - PUBPlI OWNGE ova- -ORAMSE/BLUt (STBPq RES ayRD - euJE/BED (STTtlPE) • • • WHITE RP/OI - WEP/CREOI {STBIPP tflAWiW tJtJWri HE-EMEReiiEP ' ^ NOTE IF WALL MOUNT P«EW«E. OH HELD INSTAILED FRE SYSTEM UlCROSWITCH THE TERMINALS SHOWING FACTOWl" WWlMG MUST BE FIELD WIRED CONTROL PANEL NSTALLATICJi DBflVlW; NUMBER E0imB3-OS JOB NAMEcw/POrLC CARLSBAJ3 fl66C JOB NUMBER I6!M6e HOOD TO CONTROL PANEL HOOO UGi ^ , M. anrriuL PAKEL B (Ho U|bta ita out In oat to tlf) 1 "•^^ USBT SWITCH FIELD IflRED SWITCHES TO CONTROL PANEL USD PTLorr FAN avinm UGHT BWirCB HOOO UCiIT^ --CmD CONNBCTIONS -nn " CONTROL PANEL -CE (Ha J«tita out Lg |n|TiU lit bl ! In t\rm) \ FIRE SYSTEM ICCHOSfflTCH WIRING TC CONTROL PANEL 120VAC SHUNT TRIP BREAKER WIRING AKSUL oa pntocmai Fiat iQCBoswrrcH SFAKE riHB HEUI cotracTs (NOT TOB atmCING FIRS COKTBOL PAKE, .__es J NOTBZ: rr MO FIRZ STSTEH ON BOOS lUMFSa Cl AND Am tOCETHER POWER FEED FOR CONTROLS AND LIGHTIM aB£AKEB PAKEL CCNTHOl PANK. -SB CCNTHOl PANK. -SB fzOV ISA HHEMEU-. CCNTHOl PANK. -SB lacRO-swircHis WIRINC WHEH MULTIPU: FTKE SYSTEMS CONNECTED TO ONE ElilCTHICAL PANEL £3 SHQITN HERE) CCMTBOL PANEL (ASD FAN WIRING TO CONTROL 3 PHASB 206/440/670 VOLT FAN BREAKER PANEL, SEE DRAWING I MOTOR f TABLE FOR BREAKER SIZING 1 PHASE 119 RXJ J^TO rut n to TM IZ ELECTRIC GAS VALVE CONTROL PANEL -FcD 5 -FcD 1 PfuaS 306/830 TOLT uTBF mtrm BLACK YV n:iLOW n.t£ - WAT BROWN PR - PUim.£ DIMNCE - RD BCl (STRIPE) •JH - WHITE CREEN BL/RD - ILUE/KB CSTHTPE) RD/GN - RED/aaXN CSTmPEJ A REVISIONS Al UJ DATE 8/24/2012 DWG # 1&16062 SCALE 3/4- = 1 -0 MASTER DRAWING SHEET NO. Bate S>0 • l)Ai]ioastofi)MiiiitAan(Cb^ or iloiiliil iQmiitaited. putiti n^tBttft- S)lia8e4ii»er!te wlmeat^ioD mi tee. - 3) n«sie dtai^ flf fin 2: BBSSSSEBBSi Yssaim walN' ttittqg (Kinm) CITY OF CARLSBAD PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www carlsbadca gov Project Address: f^f^f^ Permit No.: (l& { ^ I S-SJ^^ Information provided below refers to worh being done on the above mentioned permit only This form must be completed and returned to the Buildmg Division before the permit can be issued. Building Dept. Fax (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains New building sewer line? Ves X fyj© Number of new roof drains? 4_ Install/alter water line? ^ 1 Number of new water heaters? Number of new, relocated or replaced gas outlets? ^ Number of new hose bibs? ^ Tenant Improvement/Remodels: Number of Panels (involved m this project) Amps per panel (involved in this project) Remodel only - (relocate/add outlets/switches) Ves No New Construction: Number of new panels or subpanels? 3 Amps per Panel: Single Phase Number of new amperes Three Phase Number of new amperes Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps? ^ New or relocated duct worb? Ves X No Number of new fireplaces? 2_ Number of new exhaust fans? Relocate/install vent? _J Number of new exhaust hoods? 2 Number of new boilers or compressors? Number of HP ^ B-18 Page 1 of 1 Rev 03/09 INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY Date_ Business Name ess Name 0^ii^<Jrl€. Street Address Z'^^^ f/X^l OVv^f(^ ^C>V^\L<1 Email Address -^1 n .1 t/z^mj=il^//(^ k^U ri ^ A //(P- <^^A^O, PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check ail below that are present at your facility Acid Cleaning Ink Manufactunng Nutritional Supplement/ Assembly Laboratory Vitamin Manufactunng Automotive Repair Machining / Milling Painting/Finishing Battery Manufactunng Manufactunng Paint Manufactunng Biofuel Manufactunng Membrane Manufactunng Personal Care Products Biotech Laboratory (i e water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting / Forming Pesticide Manufactunng / Car Wash ^ Metal Fabrication Packaging Chemical Manufactunng Metal Finishing Pharmaceutical Manufactunng Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electncal Component Anodizing Power Generation Manufactunng Coating (i e phosphating) Pnnt Shop Fertilizer Manufactunng Chemical Etching / Milling Research and Development Film / X-ray Processing Pnnted Circuit Board Rubber Manufactunng Food Processing Manufactunng Semiconductor Manufacturing Glass Manufactunng Metal Powders Forming Soap / Detergent Manufactunng Industnal Laundry Waste Treatment / Storage SIC Code(s) (if known). Brief descnption of business activities (Production / Manufactunng Operations)., Descnption of operations generating wastewater (discharged to sewer, hauled or evaporated) Estimated volume of industnal wastewater to be discharged (gal / day) List hazardous wastes generated (type / volume) Date operation began/or will begin at this location Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authonty? Yes No If yes, when Site Contact Signature ENCINA J^'2t/f/)rLif// Title ^J^r^^yxA^'^y^ Phone Ho.j/?^ .^53-33^7 AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760)438-3941 FAX (760)476-9852 DISCHARGE PERMIT EXEMPT LIST The connnnercial enterprises listed below are a partial listing of businesses that are exempt from industnal wastewater discharge permitting under normal operating conditions They are exempt because (a) they discharge no process wastewater (i e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should^be referred to EWA Source Control staff Automobile Detailers Barber/Beauty Shops Business/Sales Offices > Carpet/Upholstery Cle/ning Services Childcare Facilities Churches Community Centers/ Consulting Service^ Contractors Counseling Services Educational Services (no auto repair/film developing) ancial Institutions/Services Fitnfess Centers/ Gas StaltsiQs (nfo car wash/auto repair) Grocery Sto}^i4(no film developing) Home-basedyBu^iciesses Hotels/Mote^ (no labn^ry) Laundromc Libranes Medical ^ffices (no x-ray develdpiing) Mortuari< Museums Nail Salons Nur^ng Homes Office Buildings (no process flow) tical Services Control Services (no pesticide repackaging for sale) et Boarding/Grooming Facilities Postal Services Public Storage Facilities Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) Countp of ^an Biego JACK MILLER VUUUUt^ Ul ^ll^^U ELIZABETH POZZEBON Assistant Director DEPARTMENT OF ENVIRONIWIENTAL HEALTH FOOD AND HOUSING DIVISION PO BOX 129261, SAN DIEGO, CA 92112-9261 Phone. (619) 338-2222 FAX (619)338-2377 1 (800) 253-9933 www sdcdeh org PLAN APPROVAL SHEET DBA: Chipotle Mexican Grill DATE: 9/7/2012 SITE: 2505 Palomar Airport Rd Carlsbad 92011 PC#: 30481 BUSSINESS OWNER: Chipotle Mexican Grill Plans are approved contingent upon the following 1) Depeirtment of Environmental Health (DEH) stamped plans shall be maintained at the jobsite and available for review at the time of the inspection 2) Changes to equipment layout, menu, or application must be submitted for approval Changes made without approval will make the plan approval null and void 3) Obtam local Building Department and all applicable agencies permits and approvals 4) All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI accredited testing agency 5) Upon completion of 60%-80% of construction, call 858-505-6660 to schedule a preliminary inspection In lieu of a plumbing inspection by DEH a Floor sinks shall be installed Yi exposed and equipped with an appropriate grill cover if no access is provided for cleaning b Dram lines shall slope V" per foot to gravity, shall not exceed 15' in length and shall terminate a minimum of 1" above the floor sink with a legal air gap Dram lines shall not intercept walkways or door ways c No condensate drainage of any kind, including HVAC can drain to the mop sink d The entire floor surface must be sloped to the floor drams approximately 1/8 inch per foot or a four feet diameter depression that slopes 1 50 (approximately V* inch per foot) e. Conduits of all types shall be installed withm walls as practicable When otherwise installed, they shall be mounted or enclosed in a chase so as to facilitate cleaning f Backflow devices shall be initially tested upon installation by a certified tester 6) The operational Health Permit may be applied for after the preliminary inspection New business owners are encouraged to be present at the time of the final inspection 7) Owners and/or operators must pass an approved and accredited Food Safety Certification course Proof of successful completion of this course is to be fumished at the final inspection 8) At the time when the final inspection is requested, the facility shall have all utilities operational and all refi-igeration shall have an ambient air temperature of 38°F or below and shall be equipped with a thermometer accurate to +/- 2°F m the warmest section of the unit All equipment is to be in place and functional 9) An air balance test shall be fumished at the tune of the fmal inspection (for facilities with mechanical exhaust systems) 10) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashes, around pipes and conduits with silicone sealant Plans reviewed by Irma Uvbungco @ 858-505-6775 CALL 858-505-6660 4 WEEKS IN ADVANCE TO SCHEDULE PRELIMENARY AND FINAL INSPECTIONS. A FINAL INSPECTION SHALL BE CONDUCTED AND AN ENVIRONMENTAL HEALTH PERMIT SHALL BE ISSUED PRIOR TO OPENING AND OPERATING THIS FOOD ESTABLISHMENT. cc File Distnct Inspector "Environmental and public health through leadership, partnership and science" CB121226 2505 PALOMAR AIRPORT RD inn Approved Date ICV BUILDING PLANNING /DI,2>I/J Encina Y N Fire 1 / Y N HazHealthAPCD 1 a Y N ) PE&M Y School Y Sewer Y N Stormwater Y N Special Inspection Y N CFD Y /N ) Comments Date Building Planning Engineering Fire i/fo/t. Date '/z Date Date Need? -'^IjJone SW Done • Done • Done • Issued