HomeMy WebLinkAbout2507 Wellspring St; ; CBRA2017-0286; PermitPrint Date: 09/12/2018
Job Address:
Permit
( City of
Carlsbad
Permit No: CBRA2017-0286
Permit Type:
2507 Wellspring St
BLDG-Associated Permit Residentia
2081928800
Work Class: Single Family Detached Status: Closed -Finaled
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Tltle:
$535,359.24
1
5.00
THE VISTAS
Lot#:
Reference #:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
204 Applied: 11/01/2017
DEV2016-0039 Issued: 01/04/2018
VB Permit
Finaled:
5.50 Inspector: CRenf
PC150042 Final
PC2016-0067 Inspection: 9/12/2018
Description: THE VISTAS: PHASE 10 / LOT 204 / PLAN 3 / 3,352 SF LIV/ 425 SF GARAGE/ 184 SF PATIO/ 280 SF CA ROOM
Applicant:
TOLL BROS INC
JOANN EPSTINE
725 W Town And Country Rd, 200
ORANGE, CA 92868-4709
760-720-5485
BUILDING PERMIT FEE ($2000+)
BUILOING PLAN CHECK FEE (BLDG)
Owner:
RANCHO COSTERA LLC -2483-INACTIVE
725 W Town And Country Rd, 200
ORANGE, CA 92868-4723
714-347-1300
COMMUNITY FACILITIES DISTRICT (CFD) FEE -RES
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES-inside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement
SEWER BENEFIT AREA FEES - B
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1 -Medium BLDG
TRAFFIC IMPACT Residential Single Family w/in CFO
TRAFFIC IMPACT Residential Single Family w/in CFO
WATER METER FEE 1" Displacement
WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 5/8" Displacement
Contractor:
TOLL BROS INC
725 W Town And Country Rd, 200
ORANGE, CA 92868-4709
760-720-5485
4:00:0SPM
$2,145.00
$1,381.38
$1,723.10
$96.00
$170.00
$110.00
$224.00
$9,743.54
$22.00
$5,099.00
$1,304.00
$934.00
$69.60
$238.00
$2,880.00
$2,800.DO
$352.00
$4,169.00
$141.00
Total Fees: $33,601.62 Total Payments To Date: $30,721.62 Balance Due: $2,880.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
' -' •'
--PERMIT INSPECTION !'flSTORY REPORT (CBRA2017-0286) .
' " ," ' ' "( 0
Permit Type: BLDG-Associated Permit Residential Application Date: 11/01/2017 Owner: RANCHO COSTERA LLC -
2483-INACTIVE
Work Class: Single Family Detached Issue Date: 01/04/2018 Subdivision:
Status: Closed -Finaled Expiration Dato: 02/18/2019 Address: 2507 Wellspring St
Carlsbad, CA 92010-5604
IVR Nurnber: 7403
Scheduled Actual Complete
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection
Checklist \tern COMMENTS Passed
BLDG-Building Deficiency No
06/21/2018 06/2112018 BLDG-84 Rough 061751-2018 Passed Chris Renfro Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
06/29/2018 06/29/2018 BLDG-82 Drywall, 062485-2018 Passed Chris Renfro Complete
Exterior Lath, Gas
Test, Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 lnterior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall
BLDG-23 Gas-Test-Repairs Yes
08/16/2018 08116/2018 BLDG-34 Rough 067202-2018 Passed Chris Renfro Complete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08122/2018 08/22/2018 BLDG-Fire Final 066940-2018 Passed Dominic Flerl Complete
Checklist Item COMMENTS Passed
FIRE-Building Final Yes
09/12/2018 09/1212018 BLDG-Final 069797-2018 Passed Chris Renfro Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
September 12, 2018 Page 2 of 2
' -
PERMIT INSPECTION HISJ9RY REPORT (CBRAi~17-0286)
Permit Type: BLDG-Associated Pem1it Residential Application Date: 11/01/2017 Owner: RANCHO COSTERA LLC -
2483-INACTIVE
Work Class: Single Family Detached Issue Date: 01/04/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 02/18/2019 Address: 2507 Wellspring St
Carlsbad, CA 92010-5604
IVR Number: 7403
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete
03/12/2018 03/12/2018 BLDG-21 051228-2018 Passed Chris Renfro Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/06/2018 04,0612018 BLDG-11 054106-2018 Passed Chris Renfro Complete
Foundation/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-12 Steel/Bond 054107-2018 Passed Chris Renfro Complete
Beam
Checklist ltetn COMMENTS Passed
BLDG-Building Deficiency Yes
05125/2018 05/25/2018 BLDG-16 069175-2018 Passed Chris Renfro Complete
Roof/ReRoof (Patio)
Checklist ltem COMMENTS Passed
BLDG-Building Deficiency Yes
06/13/2018 06/13/2018 BLDG-13 Shear 060961-2018 Passed Chris Renfro Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/20/2018 06/20/2018 BLDG-14 061551-2018 Withdrawn Chris Renfro Reinspection Complete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-24 061662-2018 Withdrawn Chris Renfro Reinspection Complete
RoughfTopout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-34 Rough 061563-2018 Withdrawn Chris Renfro Reinspection Complete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-44 061554-2018 Withdrawn Chris Renfro Relnspection Complete
Rough/Ducts/Dampe ..
September 12, 2018 Page 1 of2
,l~Jt,
-~ CITY OF
CARLSBAD
RECORD COPY·
INSPECTION RECORD: CBRA2017-0286
. 2507 WELLSPRING ST Building Division
li;fJ-1\!SPECTION RECORD CARD WITH APPROVED
THE VISTAS: PHASE 10 I LOT 204 / PLAN 3 / 3,352 SF LIV I
425 SF GARAGE/ 184 SF PATIO/ 280 SF CA ROOM
/ANS MUST BE KEPT ON THE JOB
DEV2016-0039
PC2016-0067
2081928800
11i9/2017
Ii'! CALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION
Ii'! FOR BUILDING INSPECTION CALL: 760-602•2725
OR GO TO: www.carlsbadca.gov/Bujldlng AND CLICI{ ON
"Request Inspection" CBRA2017-0286 DATE:
IF MARKED 'YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION
STORM WATER PRECON MEETING REQUIRED 760-602·2725 Allow 24 hours
IF MARKED 'YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING
Fire Prevention
Planning/Landscape
CM&I {Engineering Inspections)
#12
#66 MASONRY PRE GROUT
j )D GROUT D WALL DRAINS
#lll TILT PANELS
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#14 SUBFRAME D FLOOR OCEIUNG
#15 ROOF SHEATHING
#13 EXT. SHEAR PANELS
#16 INSULATION
#18 EXTERIOR LATH
#17 INTERIOR LATH & DRYWALL
#21
1124
1127
#23
#28 SOLAR WATER
BLDG-FINAL
CODI:; lt POOLS
#51 POOL EXCAV / STEEL
#52 PLUMBING
#53 ELEC /CONDUIT/WIRING
I j EQUIPOTENTIAL BOND
lill.f' PREPLASTER / FENCE/ ALARMS
#57 GUNITE
BLDG-FINAL
760-602-4660
7 60-944-8463
760-438-3891
Date Ins ector
Allow 48 hours
Allow 48 hours
#35
#38 SIGNS
COOE 11 MECHANICAL
#41 UNDERGROUND DUCTS & PIPING
#44 0 DUCT & PLENUM O REF. PIPING
#43 HEAT-AIR COND. SYSTEMS
cone" COMBO INSPECTION
#81 UNDERGROUND (11,12,21,31)
#82 DRVWALL,EXTLATH, GAS TES (17,18,23)
#83 ROOF SHEATING, EXT SHEAR (13,15)
#84 FRAME ROUGH COMBO (14,24,34,44)
#85 T-Bar (14,24,34,44)
BLDG-FINAL OCCUPANCY
A/S UNDERGROUND VISUAL
A/S UNDERGROUND HYDRO
A/S UNDERGROUND FLUSH
A/S OVERHEAD VISUAL
A/5 OVERHEAD HYDROSTATIC
A/S FINAL
F/AROUGH,IN
F/AFINAL
FIXED EXTINGUISHING SYSTEM ROUGH-IN
FIXED EXTING SYSTEM HYDROSTATIC TEST
FIXED EXTINGUISHING SYSTEM FINAL
MEDICAL GAS PRESSURETEST
MEDICAL GAS FINAL
COPY OF CARD
REQUIRED
Inspector
Date Ins ector
Date Ins ector
Date Ins ector
. . .
i'
Michael Baker
INTERNATIONAL
March 30, 2018
City of Carlsbad
Building Department
· 1635 Faraday Avenue
Carlsbad, CA 92008
Subject:
Inspector:
Vistas -Lots 202, 203, 204, & 205
City of Carlsbad Tract No. CT 13-03
JN 143824
Michael Baker•lnternational has performed a field survey on March 30, 2018 to field check the
building footing forms for Lots 202-205 on Wellspring Street. The results of the field survey reveal
the footing forms to be within substantial conformance, both horizontally (0.10'±) and vertically
(0.05'±) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated February 9,
2016.
Sincerely,
Tim Thiele, P.E.
Project Manager
H:\PDATA\143824_ROBERTS0N RANCH\ADMIN\CDRRESPNDNCIFORM CERTS\TOLL BRO_FORM_PA6_CERT15_202-205.D0C
PLANNING • DESU3N • CDNSTRUCTldN
5050 Avenlda Encinas, Suite 260, Carlsbad, California 92008 # 760.476.9193 it FAX 760.476.9198
Offices located throughout the Country • www.mbakerlnt1 com
' 0 0
j
Project No.: Date: Report No.:
"' • I 3;oz-s~ 10 / II(,~ :.r;,c .s
P)liect Name:
t< 0 /kf/:rjL>"'
Location: Author: Day: (circle one)
Wiru.. 5 M T W T F s s
Client: Superintendent: Contractor: Foreman: ,
[J.I t>S
Soil Engineer: Geologist:
Overcast Other:
Unit/Phase/Lots:
jl~l~J~8--~l8~l •. -"'~~"'*'-~~--~~-1..~--~~~~.1-..~=--ie~~u;.a.""II "':,, ·4,
l~itials:~.
Date:~
,~,, ltfitials: ..-P.1
Date: 3}t'> )19
Initials: ::1M
Date: ±d.i, i .:,µ I
Notes:
Footin Observation Summa :
A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at
the site are substantially in conformance with those assumed in the geotechnical report.
A representative ofLGC Valley, Inc. observed the footing excavation(s). The fabling
excavation(s) extend into the proper bearing strata and are in general conformance with the
recommendations of the geotechnical report.
1. Footing excavations should be cleaned of loose soil and debris and thoroughly moistened just prior to placing the concrete.
2. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc.
3. In the event of a site change subsequent to our observation of footing excavations and prior to concrete placement (i.e. heavy rain, a
construction/placement delay, etc.), LGC should be contacted to perform a recheck of footing excavations and site observations,
as necessary. ·
--.;{, D
Technician Hours
LGC VALLEY, INC.
Geotechnical Consulting.
White -FIie Copy Yellow -Client Copy Pink -Field Copy Gold -Client/Agency Copy
Southwest Inspection and Testing; Inc.
441 Commercial Way, La Habra, Ca 90631
(562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026
REGISTERED INSPECTOR'S DAILY REPORT I S1~_1,:Jo~ ~~>
TYPE OF D Reinforced Concrete. D Welding
INSPECTION CJ Post Tension~d Concrete D Fireproofing
REQUIRED D Reinforced Masonry D Asphalt
D
D
D
DIA/E.poxy
Wood Framing
Other
J
Job Address._,¥___ ··-,.; ·""c Tract N·o. Lot No.-7 ,. ...._,..\...· .::, .... _ (... -
Job Name . \./ ! _ r:.--·
Type of Structure --<. _ ... ·-.·:-
Material Description (type, grade, source)
'. t .. ').
Inspector's Name ·~ -\ : .... -'· .. ··-· •:..._:I : ,~,•,
P ern:iil .:No. ..-;r,:·
Architect
:..~ . Issued By ,_
E;ngineer ,. i (_ ..... r _;,.
Contractor :::.-··~ ~--. I --t-/t.::. ~
Subcontractor .,: <....
TESTS PERFORMED
AIR CONC WATER TIME
SET# TRUCK# TICKET#
SAMPLE
LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS
'; .. < :J
INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS,
REMARKS, ETC. INCLUOES INFORMATION ABOUT -"AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF
TEST SAMPLES.TAKEN: STRUCT. CONNECTIONS /WELD MADE H.T. BOLTS TORQUED) CHECKED, ETC. .
c <.. -,£. ... / c 3 -~~ l _;· -
__ ..... ~ _L..../' .._ .. -· .. ·(
,, " ..! :: .. ! <--· ---. " •· . ·°'c' !._ { 2'°-Xe_ [ , -(/f 2_ -· I (_;;> ,
·-Z c::. .:5
.J ~<...-'·. •.'€... r· ..... c_.:_. :
L z ... 17 ...... (...,. ... "i
. 'I <.... '-··
CERTIFICATION OF COMPLIANCE
I HEREBY CERTIFY THAT 1.J;l.4NE OBSERVED TO THE BEST OF_ MY KNOWLEDGE
ALL OF THE ABO~R(i,ORTED WORK UNLESS OTHERWISE NOTED. I HAVE
FOUNDTHIS Vi.01("""~ COMPLY WITH THE APPROVED PLANS, SPECIFICATION,
AND APPLICABLE SE"rTON·e::.. 0 !~__N N~J).L'.E.ING LAWS. ·
.L-~...-,.,~..-' ( \. )
SPECIALTY NO. AGENCY
.C t-~.,:." ~
f·
CONTINUED ON NEXT PAGE 0 PAGE --OF
TIMEIN TIME OUT SAMPLES
-~/-• /,. ;; #' fe' ·--~ ~--.
Appro_ved By ~ -~p C,.,·
l? Project Superintendent
White -Office Copy III Canary-Accounting Copy o Pink -Inspector's Copy o Goldenrod-Jobsite Copy
-·