HomeMy WebLinkAbout2508 GATEWAY RD; ; PCR16021; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
07-08-2016 Plan Check Revision Permit No:PCR16021
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
2508 GATEWAY RD CBAD
PCR
2132612300 Lot#: 0
Valuation: $0.00 Construction Type: NEW
Reference #:
PC#: ~j'5"Q8S0
Project Title:
Applicant:
MILOS MAKARIC
STE 125
VIASAT: ADD ROOF SCREEN
PARTIAL SET
13280 EVENING CREEK DRS
SAN DIEGO CA 92128-4696
858-793-4 777
Plan Check Revision Fee
Fire Expedited Plan Review
Additional Fees
Owner:
Total Fees: $362.50 Total Payments To Date:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
$362.50
$0.00
$0.00
$362.50 Balance Due:
FINAL APPROVAL
Inspector: Date: Clearance:
ISSUED
02/08/2016
SLE
07/08/2016
07/08/2016
$0.00
NOTICE Please take NOTICE that approval of your prqect includes the "lrrpa:;ition" of fees, dedications, reservations, or other exactions hereafter oollectively
referred to as ''fees/exactions." You have 00 days from the date this pemit was issued to protest irrposition of these fees/exactions. If you protest them, you JTUSt
follow the protest procedures set forth in C?overnrrent Code Section 66020(a), and file the protest and any other required information wth the Oty Manager for
processing in a=rdance wth Carlsbad Munidpal Code Section 3.32.030. Failure to tirrely follow that procedure wll bar any subsequent legal action to attack,
review, set aside, void, or annul their irrpa:;ition.
You are hereby FURTI-iER NOTIFIED that your right to protest the spedfied fees/exactions DOES Nor APPLY to water and sewer oonnection fees and capadty
changes, nor planning, zoning, grading or other simlar application processing or service fees in oonnection wth this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslv been oiven a NOTICE sirrilar to this or as to which the statute of I irritations has oreviouslv othenMse exoired.
Cicyof
Carlsbad
PLAN CHECK REVISION
APPLICATION
B-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Plan Check Revision No. ~ ILQ.O 2..1
Project Address 2508 Gateway Road
Original Plan Check No. CB 15-0850
Date 2/5/16
Contact Milos Makaric Ph 858.793.4777 Fax 858.793.4787
Email milosm@sca-sd.com
Contact Address 13280 Evening Creek Drive South, #125 City San Diego Zip 92128
General Scope of Work Added Roof Screen
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised:
0 Plans 0 Calculations D Soils D Energy D Other
2. 3. 4.
Describe revisions in detail List page(s) where List revised sheets
each revision is that replace
shown existing sheets
See attached
5. Does this revision, in any way, alter the exterior of the project? 0 Yes 0No
6. Does this revision add ANY new floor area(s)? D Yes 0 No
7. Does this revision affect any fire related issues? DYes 0No
8. Is this a complez~-0 Yes 0 No ~Signature ~
1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 7 60-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov
EsGil Corporation
In <Partnership witfz government for (]Juirding Safety
DATE: FEB. 12, 2016 r:J APPLICANT
riv1CJRIS.
JURISDICTION: CARLSBAD D PLAN REVIEWER
D FILE
PLAN CHECK NO.: 15-0850 (REV. #2)-PCR #16-021 ___ SET: I
PROJECT ADDRESS: 2508 GATEWAY ROAD
PROJECT NAME: VIA SAT BUILDING #11
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The'plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
MILOS MAKARIC
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacte(}.-MILOS Telephone#: 858-793-4777
Date contacted: (by\Jf') Email: milosm@sca-sd.com
~~ b) Mail Telephone Fax In Person -r::B REMARKS: On detaii6/S5.3, revise detail ![/S5.3 to 12/S5.3.
*[Miscellaneous revisions on plans. Selected Sheets are affected & partial sets with updated calculations are
submitted for review & approval].
By: ALI SADRE, S. E. Enclosures:
EsGil Corporation
0 GA 0 EJ 0 MB 0 PC 2/9
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
In Q!artnersliip witli qovernment for (]3ui{aing Safety
DATE: FEB. 12, 2016 4J APPLICANT
OJ.....:(URIS.
JURISDICTION: CARLSBAD r.:J PLAN REVIEWER
r.:J FILE
PLAN CHECK NO.: 15-0850 (REV. #2) -PCR #16-021 ___ SET: I
PROJECT ADDRESS: 2508 GATEWAY ROAD
PROJECT NAME: VIA SAT BUILDING #11
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
i2S] The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
MILOS MAKARIC
i2S] EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contactect:-MILOS Telephone#: 858-793-4777
Date contacted: (byW) Email: milosm@sca-sd.com
Mail Telephone Fax In Person
~ REMARKS: On detail 6/S5.3, revise detaii1_/S5.3 to 12/S5.3.
*[Miscellaneous revisions on plans. Selected Sheets are affected & partial sets with updated calculations are
submitted for review & approval].
By: ALI SADRE, S.E. Enclosures:
EsGil Corporation
0 GA 0 EJ 0 MB 0 PC 2/9
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
t;
CARLSBAD 15-0850 (REV. #2) -PCR #16-021
FEB. 12,2016
[DO NOT PAY-THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD
#2) -PCR #16-021
PLAN CHECK NO.: 15-0850 (REV.
PREPARED BY: ALI SADRE, S.E. DATE: FEB. 12, 2016
BUILDING ADDRESS: 2508 GATEWAY ROAD
BUILDING OCCUPANCY: B/F-1; 111-B/SPR.
BUILDING AREA Valuation
PORTION (Sq. Ft) Multiplier
plan revisions
along with updated
calc's.
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
Bldg. Permit Fee by Ordinance •j
Plan Check Fee by Ordinance
Type of Review: D Complete Review
D Repetitive Fee ~Repeats
* Based on hourly rate
Comments:
o Other
0 Hourly
EsGil Fee
Reg. VALUE
Mod.
o Structural Only
t-----2-.5--11 Hrs. @ •
$116.00_
($)
$362.501
$290.001
Sheet 1 of 1
macvalue.doc +
Via Sat Building #11 Shell Plan Change Submittal
Project Address: 2508 Gateway Road
Original Plan Check No. CB15-0850
Delta #8 Noted as Field Bulletin #007 dated 2/5/2016
No. Description of Change
ARCHITECURAL
1 -Added roof screen
-Added key notes #18 & 19
2 -Added roof screen
-Added keynotes #29 & 30
3 -Added roof screen
-Added key notes #26 & 27
4 Added roof screen details# 14, 15 & 17
STRUCTURAL
5 Added roof screen
6 Added roof screen framing details
Prepared by: Milos Makaric
Project Architect
Date: 2-8-2016
Sheet Number(s)
A4
A5&A6
A7
AD4
S2.3
S5.3
«~> ~ CITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.r<ov
DATE: 2/9/16 PROJECT NAME: ViaSat Building 11 Tl's PROJECT ID: SUP 13-03
PLAN CHECK NO: PCR 16-021 SET#: 1 ADDRESS: 2508 Gateway Road APN: 213-261-20,21,22,23
~ This plan check review is complete and has been APPROVED by the Planning
Division.
By: Greg Fisher
A Final Inspection lby the Planning Division is required DYes [8] No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to:
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
D Chris Sexton D Kathleen Lawrence D Greg Ryan
760-602-4624 760-602-27 41 760-602-4663
Ch ris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov
D Gina Ruiz D Linda Ontiveros D Cindy Wong
760-602-4675 760-602-2773 760-602-4662
Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov
D D Dominic Fieri
760-602-4664
~
Greg Fisher
760-602-4629 Dominic.Fieri@carlsbadca.gov
Remarks:
~ « ~ CITY OF
CARLSBAD
PLAN CHECK
REVIEW
TRANSMITTAL
B!J)(}.,
DATE: 02-09-2016 PROJECT NAME: Via Sat Building 11
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www .ca rlsbadca .gov
c~opy~
PROJECT ID:
PLAN CHECK NO: PCR16021 SET#: I ADDRESS: 2508 Gateway Rd. APN:
~ This plan check review is complete and has been APPROVED by the Fire Division.
By: R. Metz
A Final Inspection by the Fire Division is required IZ! Yes D No
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
D Chris Sexton D Kathleen Lawrence rg] Randy Metz
760-602-4624 760-602-27 41 760-602-4661
Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Randy.Metz@carlsbadca.gov
D Gina Ruiz D Linda Ontiveros D Cindy Wong
760-602-4675 760-602-2773 760-602-4662
Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia. Wong@carlsbadca.gov
D D D Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
Remarks:
**APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE
DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES
AND REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW.
Page 1 ofl
Carlsbad Fire Department
Plan Review Requirements Category: PCR ,
Date of Report: 02-09-2016
Name:
Address:
MILOS MAKARIC
STE 125
13280 EVENING CREEK DR S
SAN DIEGO CA
92128-4696
Permit#: PCR16021
Job Name:
Job Address:
Conditions:
VIASAT: ADD ROOF SCREEN
2508 GATEWAY RD CBAD
Cond: CON0008735
R~ Reviewed by: -------,u"-· ... -+-· __ _
[NOT MET] **APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES
OF ISSUEANCE OF
A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS,
FIRE
DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL
APPLICABLE CODES AND
REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW.
9915 Mira Mesa Blvd.
TEL (858) 536-5166
I ROHY
STRUCTURAL ENGINEERS
STRUCTURAL CALCULATIONS
FOR
VIASAT BUILDING 11 -
DELTA 8 ROOF SCREENS
CARLSBAD, CA
FEBRUARY 3, 2016
W + R JOB #14-143.02
Suite 200
WRENGINEERS.COM
fEB 0 8 20\6
San Diego, CA 92131
FAX. (8~~\~ OZJ
0h \ ~ n<i<.~ t'\
?= -c)
DAH __ _ SHEHNO. ---
JOB NO.__.;.......~.--:.....:...::;...,;....;;;. __
Loads: BLC 2, Wind
Results for LC 1, Dead + Wind
Y-direction Reaction U111ts me k and k·ft
.736K., •
. l36k,,
8:1,,
~6.6
ViaS at B 11 -Roof Screen
TECHNOLOGIES
Company
Designer
Job Number
Model Name
Wiseman + Rohy Structural Engineers
OM
14-143.02
ViaSat 811 -Roof Screen
Joint Coordinates and Temperatures
Feb 3, 2016
Checked
RISA-20 Version 14.0.0 [\ ... \ ... \ ... \ ... \ ... \14-143.02 ViaSat Bldg #11 Roof Screen\ViaSat 811 Screen.r2d] Page 1
TECHNOLOGIES
Company
Designer
Job Number
Model Name
Basic Load Cases
Envelope Joint Reactions
Wiseman + Rohy Structural Engineers
OM
14-143.02
ViaSat 811 -Roof Screen
Feb 3, 2016
Checked
Enveloee Member Section Deflections
RISA-20 Version 14.0.0 4-143.02 ViaSat Bldg #11 Roof Screen\ViaSat 81 i Screen.r2d] Page 2
TECHNOLOGIES
Company
Designer
Job Number
Model Name
RISA-20 Version 14.0.0
Wiseman + Structural Engineers
OM
14-143.02
ViaSat 811 -Roof Screen
Feb 3, 2016
Checked By: __
1 Roof Screen\ViaSat 811 Screen.r2d] Page 3
sand-lightweight concrete
TABLE 3 • Factored Loads for Kwik Bolt TZ {KB~ TZ) Carbon Steel for installation on the
of concrete~filled profile steel deck assemblies'•2·M
DESIGN INFORMATION Loads according to Figure 3
Symbol Units Nominal Anchor Diameter (in.)
3/8 1/2
Effective embedment h.,, ln. 2 I 2
Minimum concrete thickness hm'"'"'"" in. 3-1/4 3-1/4
Critical edge distance c,.,,,,.,,,,,.,o in. 9 9
Minimum edge distance c, in. 3 4-1/2
Minimum spacing Sln)J!.cWck.!x:m· in. 4 6-1/2
Factored Tension Resistance, uncracked concreia ¢NP·'·''' !b 1.0755 1,4507
Factored Tension Resistance, uncracked concrete ¢N,,,e, ib 725f> 7708
Factored Shear Resistance, uncracked concrete9·m I ¢V,o,'""'r lb 1,562 1,562
Factored Shear Resistance, crackt3d concrete"·'' <PV,:p,a lb "!,106 1,106
Factored Shear Resistance, crack"ld concrete, seismic9·'1 I ¢V"''·'"·"' lb 830 830
Tension Test Load'3, cracked concrete N!ifst,lt!No.~: lb 910 965
Torque Test Load'3 I Tt,).:;! ft-lb 25 40
tnstalla!icn must comply with Figure 3 and instructions fer use provided the anchor packaging hex.
2 Applicable for anchors installed in 3· i /4 in •. ,; < 4 concrete cover on steel proiiie deck. For h""' ~ 4 in., refer to ESR·1 917, Tables 1 and 3.
3 Strength design capacities determined in accordance with ACl Sill Appendix D and ESR·1 9i 7.
4 Strengt'l design capacities based on conore!r.• compressive strength of 3,000 psi. The characteristic pullout resistance ior concrete strengths greater !han 3,000
psi may be Increased by muttiplying the value by (f ·• /3,000)''2•
5 Factored characteristic tension design resistance fer 3/S·in. anchors calculated by normalizing ~~ •. =from ESR·:l 9i 7, TABLE 3, to 3,000 psi concrete. N,·'"'""''"co
is multiplied strength reduction phi factors 0.65 fer Category 1 and lambda factor 0.61or sand .. ligh!weight concrece.
6 Factored characteristic lBnsion design resistance lor 3/EHn. anchors calculated by normalizing N,." iram ESR-1917, TABLE 3, to 3,000 psi cc.r:crete. N._,,,,,, is
multiplied by strength reduction phi factors 0.65 fer Cate~;ory seismic factor 0.75 and lambda factor 0.6 for sar.d·ilghtwelght concrete.
7 Concrete breakout controls for 1/2-inoh anchors. N, is celcula!ed using a lambda factor ot O.S. See ESR-191 7, Section 4.1.i2. N, is mu!liplied by strength
reduction phi factor 0.65 for Catag<:Jrf 1.
13 Concrete breakout controls for 1/2·inch anchors. N, Is calculated using a lambda factor of O.EL See ESR-1,;}'1 ?, Section 4.1.12. is multiplied by strength
reduction phi fact<x 0.65 for Category 1 and strength reduction phi factor 0. 75 for seismic.
9 Sh.;;ar is governed by prfO'.rt. See ESR-1 917, Si!cllcn 4.1.12 for lambda factor to calculate Nb.
10 Factored characteristic shear lead <tV,""'~" is calculated by multiplying the ohamcterisiic resistance times strength reduction phi factor oi 0.7 for Categcry i
and lambda factor 0.6 ior sand-lightweight concrete.
11 Factored charactsriatlo shear lead !llV,,..", is calculated multiplying tr1e charac!etisiic resistance by strength reduction phi factor of 0. 7 fer Category 1 and
lambda factor 0.6 for sand-lightweight concrete.
12 Factored characteristic shear load <tV..,."·''" is calculated by multiplying the charaotaristlc resistance by strer.gtl'l reduction phi factor ol 0.7 fer Category 1, 0.75
for seismic and lambda factor 0.6 for sand· lightweight concrete.
I3 Test Leads according to 2010 California Building Code, Section 1916A7.2. Tl1e Tension Test load is 1.25 times the milxlmum design strength. ¢N,...~ was
used as an example in this tabitr:L TI1e California BuHding Code aHows a torque test to be used 1t1St,-=ad of the tension test
KB-TZ Supplement 2011 5
WISEtv\AN + ROHY Structural Engineers
= = Design Loads = =
Roof Loads ( 1 of 1)
Typical Flat Roof:
Material
4-ply Built-up Roofing
Re-roof
Backing Board
5" Foam Insulation
1.5" 20 Gage Metal Deck
Suspended Gyp. Bd. Ceiling
Sprinklers
Mise, M&E
Beams
Girders
Columns
Partitions
Total
Deck
2.0
1.0
3.0
1.0
2.3
3.0
1.5
4.2
18.0
PROJECT: ViaSat
LOCATION:
JOB NO: 14-143
Beams Girders
2.0 2.0
l.O 1.0
3.0 3.0
1.0 1.0
2.3 2.3
3.0 3.0
1.5 1.5
4.2 4.2
ram ram
ram
18.0 18.0
Live Loads: (Reducible)
Roof Mechanical Well:
Material Deck Beams Girders
4-ply Built-up Roofing 2.0 2.0 2.0
Re-roof 1.0 1.0 1.0
Deck concrete over-pour * 3.0 3.0
3 1/2" Normal Weight Concrete 54.4 54.4 54.4
2" 20 Gage Metal Deck 2.1 2.1 2.1
Suspended Ceiling 3.0 3.0 3.0
Sprinklers 1.5 1.5 1.5
Mise, M&E 3.0 3.0 3.0
WF Beams ram ram
WF Girders ram
Columns
Partitions
Equipment 20.0 20.0
Total 67.0 90.0 90.0
Live Loads:
USE: 20 psf
* in deck
43 ViaSat #l
#11
Date: 2/3/2016
Seismic
2.0
1.0
3.0
1.0
2.3
2.0
1.5
5.2
1.0
1.5
0.5
5.0
26.0 psf
20
Seismic
2.0
1.0
3.0
54.4
2.1
2.0
1.5
2.5
1.0
1.0
0.5
5.0
15.0
91.0 psf
Loads.xls