HomeMy WebLinkAbout2509 STATE ST; ; CB150800; PermitCity of Carlsbad
' 1635 Faraday Av Carlsbad, CA· 92008
10-20-2015 Residential Permit Permit No: CB150800
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
2509 STATE ST.CBAD
RESDNTL
2030543444
$301,913.00
1
0
Sub Type: CONDO
Lot#: 44
Constuctlon Type: 58
Reference #: CT130005
, Structure Type: MF5+
· Bathrooms: 0
Status: ISSUED
Applied: 03/17/2015
Entered By.: JMA
Plan Approved: 03/30/2015
Issued: 03/30/2015
Inspect Area: PY
Project Title:
Orig PC#: PC140037
STATE ST.TOWNHOMES:PHS. 1 B1
Plan Check#:
375 SF 1 ST FLR COMMERCIAU/ 1,772 SF LIV/ 444 SF GAR/ 76 SF
DECK/ 646 SF ROOF DECK
Applicant:
TAYLOR MORRISON OF CA, LLC
STE 1450
100 SPECTRUM DR
IRVINE CA 92618-4935
949-341-1289
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park In Lieu Fee_
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Plan Chk Fee
Total Fees:
Inspector:
$1,339.12
$0.00
$937.38
($500.00)
$0.00
$39.25
$6,190.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$3,931.00
FS1
($3,931.00)
$0.00
$13.00
$0.00
Payments. to Date:
Date:
Owner:
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
Ucense Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Addltlonal Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
$24,067.09 Balance Due:
Clearance:
FS1
$0.00
$317.00
$4,800.00
$0.00
$5,494.82
$5,072.14
$0.00
$0.00
$0.00
$0.00
$0.00
$210.00
$89.00
$65.38
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$24,067.09
$0.00
NOTICE: Please take NOTI al of your project Inell.Ides the 'Im of , dedications, reservations, or other exactions hereafter collectlvely
referred to as 'fees/exactions.' Yo 90 days from the date this permit was Issued to protest Imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth In Government Code Section 66020(a), and fie the protest and any other requlred Information with the City Manager for
processing In accordance with Carlsbad Munlclpal Code Section 3.32.030. Fallure to timely follow that procedure wtll bar any subsequent legal action to attack,./
review, set aside, void, or annul their Imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor plannlng, zonlng, grading or other similar appllcatlon processing or servlce fees In connection with this project. NOR DOES IT APPLY to any . .
Inspection List
Pennit#: CB150800 type: RESDNTL CONDO STATE ST.TOWNHOMES:PHS. 1 81
375 SF 1ST FLR COMMERCIAU/ 1,772 SF
Date Inspection Item Inspector Act --~ ----Comments
05/23/2016 89 Final Combo PY AP
05/23/2016 89 Final Combo RI AM PLEASE/COF
09/21/2015 39 Final Electrical PY PA
09/21/2015 39 Final Eleqtrical PY PA
09/17/2015 39 Final Electrical PY PA
07/17/2015 17 Interior Lath/Drywall PY AP
07/17/2015 84 Rough Combo PY AP
07/13/2015 18 Exterior Lath/Drywall PY AP
07/09/2015 84 Rough Combo PY AP
07/08/2015 84 Rough Combo PY NR
06/30/2015 16 Insulation PY PA
06/17/2015 13 Shear Panels/HD's PY AP
06/15/2015 13 Shear Panels/HD's PY NR
06/10/2015 17 Interior Lath/Drywall PY PA
06/09/2015 15 Roof/Re roof ,PY AP
06/01/2015 17 . Interior Lath/Drywall PY PA
05/28/2015 15 Roof/Re roof PY NR
05/27/2015 17 Interior Lath/Drywall PY PA
05/26/2015 16 Insulation PY PA
05/13/2015 17 Interior Lath/Drywall PY PA
05/00/2015 17 Interior Lath/Drywall PY PA
05/04/2015 14 Frame/Steel/Bolting/Weldin PY PA
04/14/2015 11 Ftg/Foundatlon/Piers PY PA
04/13/2015 81 Underground Combo PY NR
04/06/2015 22 Sewer/Water Service PY CA
04/03/2015 21 Underground/Under Floor PB AP
Wednesday, May 25, 2016 Page 1 of 1
i~
~~ITY OF
CB150800 2509 STATE ST
CARLSBAD
Buildlng Division INSPECTION RECORD STATE ST.TOWNHOMES:PHS. 7 81
375 SF 1ST Fl R COMMFRCIAU/ 1,77? SF LIV/ 444 SF
GARI 76 SF DECK/ 646 SF ROOF DECK
RESDNTL CONDO ~ ""fSPEcnON RECORD CARD WITH APPROVED
.ANS MUST BE KEPT ON THE .JOB Lot#· 44 TAYLOR MORRISON OF CA, LLC
0 CALL BEFORE 3;30 pm FOR NEXT WORK DAY INSPECTION
Ii'.! FOR BUILDQNG INSPECTION CALL: 760-602-2725
"OR GO TO: www.carJsbadca,goy/BuHdlng AND CUCK ON
"'Request }nspectionw
Rl:~URD COPY
DATE: :~ '·s t ')'~
Required Prior to Requesting BulfdJng Final tf Checked YES
Plannfng/l.and5cape
CM&I (Engl=crlng Inspections) 760-438-389 l Call before 2 pm
Fire Prevention 760-602-4660 Allow 48 hours
Type of Inspection
CODE i, ELECTRICAL . Date Inspector
131 0 EI..ECTRJC UNDERGROUND DUFER
REJNFORCED STEEL 134 ROUGH ELECTRIC
Pllt MASONRY PRE GROUT #33 0 ELECTRIC SERVICE O TEMPORARY
D GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC
iio TILT PANELS #39 ANAL
#11 POUR STRIPS Cnr,r-~1 MECHANICAL · .' .. ·
#11 COWMN FOOTIIIGS #41 UIIDERG.ROUND DUCTS & PIPING
#14 SUBFRAME O ROOR O CEIURO 0 DUCT & PLENUM O REF. PIPING
1115 ROOF SHEATHIIIG
#13 EXT. SHEAR PAJfEtS
1116 INSULATION
#18 EXTERIOR LATH UNDERGROUND (11,12,21,31)
#17 INTERIOR LATH & DRYWALL #82 DRYWAU.,EXT LATH, GAS 1ES (17,18,231
#51 POOL EXCA/STEEL/BOND/FBICE #83 ROOFSHEATING, EXTSHEAR{U,151
#55 PREPLASTER/ANAI. 184 FRAME ROUGH COMBO (14,24,34,44)
T-Bar (14,24,34,«)
FINAL OCCUPANCY (19,29,39,49)
UNDERGROUND OWASTE O WTR
#24 TOP OUT O WASTE O WTR A/S UNDERQROUNDVISUAL
#27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO
#23 GAS TEST D GAS PIPINQ A/S llRDERGROUND FLUSH
#25 WATER HEATER A/5 OVERHEAD VISUAL
#28 SOLAR WATER S OVERHEAD HYDROSTATIC
#29 ANAL A/SRNAL
F/AROOG~N
#600 PRE-CONSTRUCTION MEETING F/AANAL
FOUOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN
ltti1JS NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST
#607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM RIIAL
#609 NOTICE OF VIOLATION MEDICAL BAS PRESSURE TEST
#610 VERBAL WARNING MEDICAL GAS AMAL
StE BACK FOR SPEC1Al NOTES
C(11t1iP.1wu.; ln:,pfclim1 & Mmen't1/,f Tesfing
So,,TTlt.JT' -·~--_i•, 'TJC"I' _ST.' ~~.&.AAA..A..A.A.A~>~~~~ . V .I. JLll 'IV£!.,..,_ ·~, w V -~:y "W ~,,,-"C'"..,.-v ~ r<::;;.Y ....,.. ·, .,. ""."'
Inspection & Testing, -lnc. 441 Commercial Wa1. l.,11 Habt~. CA 90<,Jl-6168
,July 28, 20:l;S
ijull,ding Offic{al
City of cartsbad
Department of SuUding ,an,d 'Sqfety
1635.-Farada:y Ave.
Carl$bad, Calffornla 92-008
(562) 941-2990" {714) 526-8441
, FAX (561) 946-0026
:SPECIAL INSPECTOR'S !FINAL PROJECT REPORT
Project Name:
Address~
O~er:
Seagrove 'Fownhomes
State· street,'BuiDding # .6
TayBor Morrfsc;n1
Un!t#'.Add~
·4Q. 2517 :State Stre~
41 25,15 State.St~et
42 2513 state Street
43 25'11 state Street
P-er.,,:I~
C~14~S24
CB143S23.
CB143S22
CRJt43521
"'n!t# Address
44 2509 state SJ.reet
45· 2,507 State street
46 2505 State St.reet
47 2503 State Street
Permit
CB·150800
Cl:J150799
CB143509
C.B1.i3S,08
This is to· certify-that. So,u.tjlwest In.sp~ctlon E!nd Testing, Inc. was employed to. perform ·spedal Inspection on
the a'bove mer;ttloned.project at t.heabove address, which r~ulr~d continuous inspection per sectlon 1701 of
2013 Ca,llfonila, BLiilolhg. Code'.
Brett Alb linger -Reinf6r.ced Concrete, Post Tenslotled Concrete, SD #656
William Bewen -Reinforced· Concr.-ete, .Post Tensioned Concrete, SD #5:4'1
Tom'Woods;. RelnJprcE;i,d Con~rete, PostTensioned Concrete, SD# 377
George R. M<YQers II--Relnfor~d C:011<;:ret.e,, Post Tensl0ned Concrete, SD# 1122
Steven L. God'
Pr.esident
SLG/IRW: amc
Ian R. Wadde,11, P.E.
P.'rlncipal E_ng_lneer
expressed or hriQiled.
LTG-..,
r
'2-
{'city of·
Carlsbad
CIRCUIT CARD
8!"36
Development Services
Bulldlng Division
1635 Faraday Avenue
. 760-602-2719
www.carlsbadca.gov
THIS CARD MUST BE F1UJID mrr AND AV All.ABU! AT nm SERVICB Rl'1UJPMENT POR THE ROUGH INSPBCTION
Address: 2 JO !} r .J-,fJ,-({' r .s,-,1.,, 1rr-Permit Number: r,.(. 1 .ro J-o tJ
Owner: 4,,,,... -'•,,1Ar.su..J Phone: Pt t 't) j v J -fl'. rJ o Area In Sq. Ft. ~,'77 Contractor:~cll ,t...i 1~6-Plf'~Atr.;e Phone: (n /9 5 79 "'S""t\O
PANEL: G-1-\-~ 10, o~c .. A.LC. -:2...4~ VOLTS I 0 ~ WIRE
LOCATION CKT 8KR WIRE MISC REC REC LTG MISC WIRE BKR
SIZE SIZE TYPE SIZE TYPE SIZE CKT LOCATION
1 /< I T<:.i/8 1 ~CJ J-:i, CH) 4 f) /E.j ~, ID C..\) ;is 2 A le
lf>t IC.~ 3 2.0 /:L. cu I' '.:>..L( ov /I) cu .;15 4 A /C"
&A-T>i-5 5 20 ,2 c:u "S D t.:: 0/ I;;.. C() ;,2.c 6 NU.A/(
~I~ 7 Zo , ,__ CV l-l ;;;J-c.. 10\/ I~ ccJ ..Z<l 8 -spL.1T
~(.,() t 9. /5 IV cu L I I -:i c..u ;J..O 10 i,.j~ffc~
~~£ 11 IS ti./ c.u 3 j 7;:L c.v '2,l) 12 . F=A-L/
-ID~P~4<. 13 IS' Ill <::, V I '"J 7 7i l'-1 cu /-s 14 ~EoB'ITT-.
~«:,~ 15 lS: t 'I-Cu I l-, 4· I /Y. GD I 5: 16 ~~E/f'c
/I J;iv~V/1TA r~z_ I '5 l y. <:u 2 'f ,~ t'f' CV IS-18 P,1.-(t:E/~ ,., ~AS /},wf 19 /-s' { "} cv *'7 l~ ' ( llf C. \.) /5" 20 V>7A'$, ,SCV
<e;:"T~ ,.,.,ac; .. /)IIJ/N(r 21 .:LC 72-cu '1 5' &( 2-14 c.v IS' 22 !~¥k.'JI&
' 23 I 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 .\ 40
41 42
MAIN:0 ~~i AMP 8RK/FUSE [X' MLO Computed Load 7 '-I •. {p:s AMPS
BUS: AMP S-C4IJcu/tltlon Workahfft on ti.ck
Branch cl rcults required:
Service entrance~ ~rw: A) Llghtlng Circuits 220 -3(b), 4{d)
A) Size: No. ~ 0 8) Type: CU O AL
C) lnaulatlon: D) Condufs-ize: __
B) Two Small Appnance Circuits 210-11(e)
C) Laundry Circuit 220-16(b)
Service ground/bond: L
8) Type: ·gf cu O AL
D) Central Heating Equipment 422-12
A) Size: No. '3 D E) Bathroom 210 • 52(d) i Clamp locatlon(a): '
UFER 250-50(c) Remarks:
Water Pipe 250-104
D Ground Rod. 250-52
D
G~ locatlons 210-8, 680 -70: I csrtlfy that all tarmfnatlon~ have been torqued In aCCOfdsncs with manufacturer's
Bathroom(s) J:ii!' Kitchen, /nwuotions and that the work 3/Jown on this circuit csrd·represents the full extent of I Garage(s) . DHydromassega Tub the worl< performed under th/8 pennft.
Outdoors· D -~ D OWner AFf rotected Clrc. ~ 12 'Pf. Contractor :!"ll-t It.. c, 1./. ,:;.__-.,..,, .11!.A II f.'"i. F
Bedroom(s) f;,v t;f-.y v> tt!=RE D Signed ~ ---{"I. .J Date ~ / '7116"
-(;Ill -•
B-l Page 1 of 2 Rev. 03/09
)
>
2.
~
t3
'1'tr.
'
/
/.
I•
SINGLE FAMILY DWELLING
ELECTRICAL SERVICE LOAD CALCULATION
As an alternative method, the STANDARD METHOD
'.found In ARTICLE 220·ofthe National Electric Co<!e. may be used
1. · GENERAL LiGHTING LOADS
DweRlng ~, It] sq.ft.x3VA=-220-3(a) -'2,53/ VA
Small appliance loads-:-220-16(a) 1500 VA x ;.2. circuits= 3, ooo VA
· laundry loa~_ -220-16(b) 150,0 VA x . circuits= (, SQO VA
Gen~nsl Ughtlng Total//, o 3 / VA . .
2. · ·COOKING.EQUIPMENT LOADS-Nameplate Value-·
~ge . · --. . VA= . ---VA
Cooktop · VA= VA ~noo ~= ~
. . . .. Cooking EqulpmentTotat ______ VA
3. E~EeTRIC DRYER 220•18 (Nameplate, 5000 VA minimum) .
Orjer . i. ·r-VA=. Dryer.T~I ______ VA
4. ·FIXEJ) APPWANCE LOADS 230-30 (b) (3)
Dishwasher =
0JSP:Q881 ~
Compactor=
Water: Heater =
Hydr~ge Bathtub 111
Microwave Oven = ,
Built-In Vacuum =
=
5. OPTIONAL. SUBTOTAL (Add all of the above totals}
6. APP-LYING DEMAND FACTORS -TABLE 220-30
· Flrst 10,000 VA x 100% =
Optional Subtotal (from line 5) { Re~lnlng 4'..i 17~/ VA x 40%zz •
7. HEATING OR AC LOAD -TABLE 220-30 Larg~ of the.He~tlr,ig or AC Load=
It s-oo VA
. 7.SO VA ____ VA·
____ VA
______ VA
, L7"0 VA ____ VA
____ VA
Fixed Appliance Total ~ l _7.SO· VA
('-I, 7g/ VA I
10,000 VA
'( 'f / "1.. VA
<e,ooo VA
8. OPTIONAL LOADS TOT AL (Add totals from lines 6 and 7) = li/=tl~ VA -
9. MINIMUM S~RVICE SIZE :11 Optional Loads Total =
• •
1240 Volt
7L/, «> 3 An:ipere'
(Please put total on front of card under Computed Load)
. ·-· : .. ..,,. ,.
~-.~': /
:'•,;I
,.. • ~ I .... ~. • .. ' ,., ........ . ,