Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2510 EL CAMINO REAL; ; CB042063; Permit
,v~t:35 bk~ -ru\&G City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 07-15-2004 Commercial/Industrial Permit Permit No: CB042063 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2510 EL CAMINO REAL CBAD Tl Sub Type: Lot#: $6,510.00 Construction Type: Reference #: SAV-ON DRUGS #9479 -217SF Tl ADD WALLS & SOME ELECTRIC COMM 0 NEW Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check#: ISSUED 05/26/2004 KMT 07/13/2004 07/15/2004 Applicant: Owner: COURTNEY ARCHITECTS 766 COLORADO BLVD 90041 323-344-5555 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee · Pot. Water Con. Fee. Meter Size Add'I Pot. Water Con. Fee· Reel. Water Con. Fee · $76.59 $0.00 $49.78 $0.00 $0.00 $1.37 $0.0Q $Ci.OO $0.00 $0.00 $0.00 $0.00 $0.00 '$0.00 $Q.0Q·· $0.00 $0.00 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA.Fee ¢FD Payoff Fee PFF PFF (CFO Fu.nc;l) Ljcense Tax · · \_icense tax (CFO Fund) Traffic Impact Fee Traffic Impact (CFO Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage F~e Sewer Fee Redev Parking f=ee Additional Fees ·. TOTAL P!=.RMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $35.00 $24.00 $0.00 $0.00 $0.00 $0.00 $186.74 Total Fees: $1·86.74 Total Payments To Date: $49.78 Balance Due: $136.96 . Inspector: ~ ~ FINAL APPROVAL Date: lo/;"/2 t -; - 6685 r17 .. v /11)/ri' --' \JLf 0002 01 02• CGP 136°96 Clearance: ------ NOTICE: Please take NOTICE that cipproval of your project includes the "Imposition" of fees, dedic9tions, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days·from the date this permit was issued'to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030, Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or-annul their imposition. You are hereoy FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or.other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any f es/exactions of whi h h v r vi I n iv n N T E imilar hi r ,whi h h atu f limit ti ns has reviousl otherwise ex ire . l o-9 I (cµ1~1Ei 1Le. PERMIT 'APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHE<;K NO. (lf30Cj clCCf 3 /J /,) 5-/{) ' t:',.;,C__j EST. VAL. __ Cl_,_"-'tT..,...,..,,.,---,-,,..,----l/ .·1 Address (include Bldg/Suite #) Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Existing Use ~;-"2-11 <4. FT· SQ. FT. #of Stories ,,2, . CONT:A:CT PERSQN/lif <liff~fKnt frori\fiipplici!foti e-1 l,~ City :·o Owner D Agent for Owner ~o v~ City 1-t)L"{]O 'f, "78 # of Bedrooms # of Bathrooms State/Zip Telephone# Fax# Telephone# Name ,,_ ~K '5Y' ·CONTRACTOR• COMPANY:;NAME i, Address ' City State/Zip Telephone# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031,5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). •. '5Tl2\f~t.XHJS ~ 2'30 CAt.IB: P,NTC£fS:-0,; S6i,la2KB-.JrE CA 9'fC(-'3k:l(-78W Name ~ • . Address City State/Zip Telephone # State License_# .J53 t::x:) 1 License Class B City Business License# -~ ~ ---- \ Designer Name Address City State/Zip Telephone , ·1 State License # _________ _ 6; · :WORKE.RS' .COMPENSAT!ON Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of th or" for which this. permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this.permit is issued. My worker's cbmpensation insurance carrier and policy number are: ) J ,,.-. Insurance Company 3TJ:s1 E F( l, )Q Policy No, } j cJf CJI -ZCQ3 Expiration Date b 2] G) (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) \ 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California, WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred Xhousand do $100,000), in a diJ"l! to the c of compensation, damages as provided for in Section 3706 of the La 'or c~ , interest and attorney's fees. SIGNATUR ·· Ja.z_ DATE_..,__,_::%,-J'--"-~+--- ~r~~:a~fi O t~~tDIE!iD::~~~;!~~-he Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name I address / phone number/ contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): ________________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): __________________________________________________________ _ PROPERTY OWNER SIGNATURE ---------------------------COMP L ~ts: i ;t HIS:' SECT 10 N FOR NON,lfESIDENTiALBUILDiNG PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Subs!ance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTI\UCfl9N LENDING'AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME ______________ _ '.9; · AfJ>l::ICAN'l'iCeRTIFICA TION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit\! of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is com~ 80 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE -~====UZD-~---1-f.L_,._,,._ __________________ DATE ,1/½v\ 'UJ \ '2~ WHITE: File YELLOW: Applicant PINK: Finance .~ . ) City of Carlsbad B·ldg Inspection Request For: 1 0/04/2004 Permit# CB042063 Title: SAV-ONDRUGS #9479 -217 SF Tl Description: ADD WALL$ & SOME ELECTRIC Type: Tl Job Address: Suite: Location: Sub Type: COMM 2510 EL CAMINO REAL Lot 0 APPLICANT COURtNEY ARCHITECTS Owner: Remarks: Total Time: Inspector Assignment: TP Phone: 6197018860 lnspoctor: /2_ R~quested By, STEVE Entered By: ROBIN CD Description Act Comment 19 Final Structural AL 29 Final Plumbing t 39 Final Electrical 49 Final Mechanical -- Associated PCRs/CVs CV030663 CLOSED Z-BANNER; lnst1ection Histoty Date Description Act lnsp Comments 09/30/2004 89 Final Combo co TP MTL BOXES BONDED 09/28/2004 14 .Frame/Steel/Bolting/Welding AP TP T-CEIL TIE IN 09/28/2004 19 Final Structural NR TP 09/28/2004 24 Rough/Topout WC TP 09/28/2004 34 Rough Electric co TP BONO MTL BOXES 09/28/2004 44 Rough/Ducts/Dampers WC TP 09/03/2004 17 Interior Lath/Drywall AP PK 08/31/2004 14 Fralile/Steel/Bolting/Weldihg PA TP SEE JOB CARD · 08/31/2004 34 Rough Electric AP TP SOFFIT LITES 08/16/2004 14 Frame/Steel/Bolting/Welding co TP CORR CONF. W/CONT. 08/12/2004 14 Frame/Steel/Bolting/Welding co TP SEE CARD 08/12/2004 34 Rough Electric co TP EsGil Corporation In <Partnersfi.ip witli. government for <Bui{aing Safety DATE: 1 /8/04 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-2063 PROJECT ADDRESS: 2510 El Camino Real PROJECT NAME: Sav-on -Tl SET:11 ~~ANT ~ D PLAN REVIEWER D FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be co'rrected. and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held ·at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant · contact person. D The applicant's copy of the .check list has been sent to: ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Mail Telephone Fax In Person D REMARKS: By: Doug. Moody Esgil Corporation D GA D MB D EJ D PC Telephone #: Fax#: Enclosures: 6/29/04 tmsmtl.dot 9320 Q!esap.e\lk~Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 -----=-- --, -·-j ,_, .-!I EsGil Corporation In <Partnersliip witli fiotJernment for <Buifding Safety DATE: 6/7/04 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-2063 PROJECT ADDRESS: 2510 El Camino Real PROJECT NAME: Sav-on -TI SET:I ':!~Cf-NT ~ 0 PLAN REVIEWER 0 FILE 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith ~ill substantially comply with the juris_diction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have_ significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gl The check list transmitted herewith .is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is endosed for the jurisdiction to forward to the applicant contact person. . ; ,._,:·r.,, [gl The applicant's copy of the ·check list has been sentto: .:: .... •: Courtney & Le / Nelson Onqueza · .. '/ ; . 766 Colorado Blvd, Los Angeles, CA 90041 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. IZ] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nelson Onqueza Telephone#: 323-344-5555 Date contacted: te,{ ~oLf (by:\~ ) Fax #: 323-,344-5556 Mail ~lephone--F·axv--In Person D REMARKS: By: Doug Moody Esgil Corporation D GA D MB O EJ D PC Enclosures: 5127/04 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 921.23 + (858) 560-1468 + Fax (858) 560-1576 ,City of Carlsbad 04-2063 6/7/04 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS -PLAN CHECK NO.: 04-2063 OCCUPANCY: M TYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 5/26/04 DATE INITIAL PLAN REVIEW COMPLETED:_ 6/7 /04 FOREWORD {PLEASE READ): JURISDICtlON: City of Carlsbad USE: Retail ACTUAL AREA: 217 sf STORIES: 1 HEIGHT: OCCUPANTLOAD: 2 DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/27/04 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained iri the Uniform Building Code,.::. Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws · .. · regulating energy conservation, noise attenuation and access for the disabled. This· plan review · -· is based on regulations enforced by the Building Department You may have other .corrections· . based oh laws and ordinarices enforced by the Planning Department, Engineering Department, .. · Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Coqe, the approval of the plans does not permit the violation of any state, county or city law. To spe.ed up the recheck process, please note on this list· (or a copy) where each correction item has been addressed, i.e., · plan .sheet number. specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. · · TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot · City of Carlsbad 04-2063 6/7-/04 _ Please make all corrections on the original tracings, as requested in the ·correction list. Submit three sets· of plans for commercial/indwstrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: . 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700~ The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. UBC Section 107.2 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other perm.anent equipment. Please provide the designer's or contractor's construction cost estimate of all work proposed. 2. Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is· restricted (without City approval) to one and· two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 3. Please revise the plans to show the electrical conduit and conductors feeding the new condenser. 4. Plec;1se revise the panel schedules to show the new condenser. 5. Please review for compliance and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 6. Please indicate if the lighting system is to be altered, if so please provide complete plans. Please provide the required energy compliance forms. The L TG forms shall be signed and imprinted on the plans To speed up the review proc-ess, note on this list (or a copy) where each correction item has been addressed, Le., J?lan sheet, note or detail number; calculation page, etc. · Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. City of Carlsbad 04-2063 677/04 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes CJ No CJ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any · questions regarding these plan review items, please contact Doug Moody at Es·gil Corporation. Thank you. •• .. •• r -• r• . ' " .. ~. • ! . : ' CITY OF CARLSBAD POUCI-ES AND PROCEDURE I . JUMBER: 80-6 SUBJECT: ROOF MOUN1ED EQUIPMENT EFFECTIVE: 5/1/92. SECTION: BUILDING DEPARTMENT SUPERSEDES: . 80-6(9/10/80} 80-6{5/01 /81) . i ==============::;::==:===============~i -; PURPOSE: INTENT: POLICY: I PROVIDE INSTALLATION STANDARDS FOR All ROO'F MOUNTED E:QUIPMENT A.ND ; PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS. ! A. 8. C. 1. 2. 3. 4. 5. -"6, 7 ... Maintain roof integrity, . Prevenfhazardous condition to firemen who must fight fire on ths roof. Provide an installation that is aesthetically s·ensitive to the building and ·the adjoining properties: · All equipment shall. be concealed from view and the design¼ shall meet the . · approval of the Planning Department. · I i i i ' i i ! i i I i ' I i ' i All equipment shall be specific~lly designed and approved for exterior use and shall be approved by the Cit',' of Carlsbad Building Department. . l All roof mounted equipment shall be on a pJ·atform which shall be an integral / part of the-roof--flashed and waterproofed. When _a screen is.approved, it shall ] have as fevv roof conne.ctio:1s as possible and be structurally adequate. -. : All electrical, plumbing, mechanical duct-work and related piping shall be insi.de . the building.and not on tha roof . .All corine.ctions related to equipment shall be· · made in the same roof opening on the platform or have the prior approval from the building official. Sewer vents shall be brought to one main vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity. Air exhaust fans and other eqliipment shall be within the building and use the ~ame roof opening ·where restrooms and other equipment are back to back or in general proximity. . . Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior.approval fr~ni the building official. . . Where new equipment is in.sfall~d·; unu~ed·or abarJd(?ned equipmen"t, including·· all roof mo·unted piping, ele.ctric-al, mechanical, duct, ~n.d other· related · . · appurtenances ·shall be removed from roof and unosed openings p.roperly seated -to 01aintai_o roof integrity. · · · 4 The architect should, through de-sign, conceai"the heating/AC uni-t ~nd othe!'. equipment \\'.heth~r they are pn the roof ot elsewhere. · · initiated By: v· •. .City of Carlsbad 04-2063. 6/7/04 !VALUATION AND PLAN CHECK FEE · JURISb.lCTION: City of Carl.bad PREPARED BY: Doug Moody PLAN CHECK NO.: 04-2063 DATE: 6/'J /04 BUILDING ADDRESS: 2510 El Camino Real BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VN BUILDING AREA Valuation Reg. VALUE PORTION (Sq.Ft.) Multiplier Mod. Tl 669 30.00 Air Conditioning Fire Sprinklers . TQTALVALUE '. •Jurisdiction Code '··. cb By Ordinance •,: 1994 UBC Plan Check Fee Type of Review: 0 Com[>lete Review D Structural Only . D Repetitive Fee it,;; .Repeats f~! Comments: D Other D Hourly J I Hour * Esgll Plan Review Fee ($) 20,070 .. ~-~ i .: 20,070 $184.391 $119.851 $103.261 Sheet 1 of 1 rnacvalue.doc PLANNING/ENCilNEERINC APPROVALS . . PERMITNu~a·e~ca · CJ-Cf-7--C?~3 DATE. os-2~,. oy .. ADDRESS ·z._6(0 6(-~i,ia-{<-er,.,( -------~-----_.:.;..----,------,----- . RESID&NTIAL RESIDENTIAL ADDITION MINOR · < < $10,000.00>. . . . OTHER . Sv ~ J) 0!3j. S oocs/Mlsforms/Planning Engineering Approvals · PLAZA CAMINO REAL .. · CARLSBAD COMPANY STORES VILLACE'·FAIRE ... COMPLETE. OFFICE BUILDING _ . . DATE tJ) / 2,_$ -rzy DATE · 11o2#/4'r Carlsbad Fire Department 042063 1635 Faraday Ave. Carlsbad, CA 920Q8 · Plan Review Requirements Category: Fire Prevention (760) 602-4660 Date of Report: _o_e1_1 a_12_0_0_4 _______ _ Building Plan Reviewed by: Name: Courtney & Le Arch. Address: 766 Colorado Blvd. City, State: Los Angeles CA 90041 Plan Checker: ____________ Job#: _04_2_06_3 ____ _ Job Name: Sav-On Drugs Bldg #: CB042063 ----------------~ Job Address: 251 o El Camino Real Ste. or Bldg. No. IZI Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and/ or specifications provided in your submittal; therefore any changes to these items after this date, including field· modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and/ or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. 1st 042063 2nd FD File# 3rd Other Agency ID c+> ~ Cf) I I -------- (El S RAGE ®------~~~~~µ---""'Fi'i'rrrni'i'i'i~mi=t~~~=~~ (El WOMENS RESTROOM 5 ,,,,- / ' '-... ,,,,- 1 .'-... / ' 0 0RtN I ,,,---'---j-/ ·'---.'-... / ' .'-... ,,,--I -'--- REAR 4 MEZZANINE FLOOR PLAN 1/," • 1'-0" FINISH FLOOR ELEVATION, EXISTING RE, 3.9A ALL FIXTURES #JD EQUIPMENT LEFT I RIGHT FRONT OCCUPANT LOAD AND EXIT WIDTH ANALYSIS 1/a" • 1'-0" OCCUPANT LOAD: AREA 1: RET~L SALES -GROSS AREA = 30 S.F PER OCCUPANT 19,216 SF /30 AREA 2: WAREHOUSE/RECEIVING AREA GROSS AREA = 300 S.F PER OCCUPANT AREA 3: BREAKROOM-GROSS AREA = 15 S.F PER OCCUPANT TOTAL OCCUPANCY LOAD EXIT WIDTH ANALYSIS: TOT AL EXIT WIDTH REQUIRED = TOT AL aces. X 0.2" TOT AL EXIT WIDTH PROVIDED: TOT AL EXIT REQUIRED: TOT AL EXIT PROVIDED= MAX. ALLOWABLE DISTANCE TO AN EXIT (SPRINKLERED): 7,800 SF /300 = 402 SF /15 MAX. OVER-ALL DIAGONAL OF SALE AREA= MIN. EXIT SEPARATION REQUIRED: EXIT SEPARATION PROVIDED: 641 26 27 694 aces. 139" OR 11'-7" 181" OR 15'-1" 2 2 250'-0" 206'-6" 103'-3" 162'-4" Cf> 12'-1" EXIT •1 D D D 1 FLOOR PLAN 1/," • 1'-0" FINISH FLOOR ELEVATION 100'-0" RE• 3.9A ALL FIXTURES #JO EQUIPMENT ~ D REAR ... (ffil LEF1'~ FRONT D RIGHT ~ I I I I I ! 1· q) I I -----------® -----------@ -------. ---® ---------. © ----------® ----@ b [DJ :.: "' iii 0 • a, <( r,.. a:: w ~ f- 0, a:: () ci :z LL.I~ CXJ a::: LL.I 0 0 a::: 0 I-N (/) 0 0, (.!) :z <C :::::,~ (.) ~ (.) ~ :z .....J m 0 LL.I (/) •o .....J ~LO 2E Cl) N (.) t ,, SUBMITTAL DATECSl OWNER / AGENCY 05/25/04 05/25/04 REVISIONS RAWN NO PROJECT 04025.05-D8 CHECKED OTB DATE JL/NO SHEET TITLE FLOOR PLAN SHEET 3.0A