Print Date: 07/12/2018
.
Permit No: CBR2018-0908
Job Address: 2510 Navarra Dr, 515
Permit Type: BLDG-RsidentiaI Work Class: Alteration . Status: Closed - Finaled
Parcel No: 2161705123 Lot U: Applied: 04/13/2018
Valuation: $6,743.95 Reference U: , Issued: 05/24/208
Occupancy Group: Construction Type: Permit
Finaled:
U Dwelling Units: Bathrooms: Inspector: AKrog
Bedrooms: Orig. Plan Check It: ' Final
- - Plan Check #: - Inspection: 7/12/2018 1:35:31PM
Project Title:
Description: CARRILLO: 145 SF REMODEL TO CONVERT DEN TO BED & FULL BATH
Applicant: Owner: .- Co-Applicant:
COREY PORO FRANCES V CARRILLO . EDWARDS CONTRACTING AND
2510 Navarra or, 515 MANAGEMENT
CARLSBAD, CA 92009
619-888-9806 760-445-7355 . . 1625 Alvarado St
Oceanside, CA 92054-5903
760-529-7867
BUILDING PERMIT FEE ($2000+) . $8835
BUILDING PLAN CHECK FEE (BLDG) $61.84
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL - , $41.00
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $49.00
SB1473 GREEN BUILDING STATE STANDARDS FEE . $1.00
STRONG MOTION-RESIDENTIAL . .- , $0.88
Total Fees: $242.07 . ' Total Payments To Date: $242.07 , Balance Due: . $0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and swer connection
Fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise ex'pired.
I /
--
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 IF I www.carlsbadca.gov
1 O110WING APPROVALS REQUIRED PRIOR TO PERMIT ISSUA : DPLANNING DNERi'Ô Dáüii.bIN& DARE, DHEALTH DHAZMATIAPCD I
1m
r ( City of
--
a..r1sba.d.. -
-
, Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
,
email: .buildingcarlsbadca.gov
www.carlsbadca.gov
. Plan Check
Est. Value
P1 Ck D an, eposif
Date kA —' -
JOB ADDRESS - - .
-
-
2510 Navarra Drive SUITE#/SPACEØ/UNITC
515
AFN - CT/PROJECT # LOT U PHASE U U OF UNflS
99
1#13EDROOMS
.1
U BATHROOMS
.1.5
TENANT BUSINESS NAME , CONSTR. TYPE 0CC. GROUP
DESCRIPTION OF WORK In "u Square Feet ofAffectaduliea(s)) . *
upgrading Den areaifltoeiclosed bedroom with closet arid half bathróm uPgàdédint6füil bath.
eziT•\'-\ .' ..
EXISTING USE PROPOSED USE: GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING IFIRESPRINKLERS
den area bedroom YES[ NC YESNO YESDNO
APPLICANT NAME - . ., PROPERTY OWNER NAME
Primly cantiecil
.
V
Trinces'carrillo
ADDRESS . ADDRESS
2510 Navarra Dnve #515
CITY STATE ZIP CITY . V STATE ZIP. -.
FFAX
Casbad CA . 92009
PHONE V PHONE . . FAX
7604457355
EMAIL V
V EMAIL .
V V
V
V V
V chiãmonkeymàiLcoM
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME - V -.
V Edwards Contracting & Management ADDRESS
V
ADDRESS
.. 1625 AI' vado Street
CITY ' STATE . ZIP CITY V STATE ZIP V
V OCeanside .CA .92054 PHONE FAX . PHONE V FAX
EMAIL EMAIL
V . :iuike@edwãrdsmgmtcom
-
ISTATE LIC U STATE UC 1015255 cues B ILIC__L
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter. improve, demolish or repair any structure, prior to its issuance, also requires the V
applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he Is exempt therefrom. and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). . - -
Workers' compensation Declaration; I hereby affirm un erpenaltyof perjury one of the following decaretlons.' -
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I have and will maintain worke compe satlon, as required by Section 3700 of the Labor Code, for the performance of the work for which this it* issued. My workers' compensation insurance carrier and policy
numberare:InsuranceCo, - __tateornpensation Insurance Fund Policy ' 92204892 ' Expiration Dot. _10!271.2018i
section need not be completed if the permit is for one hundred dollars ($100) or less.
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of
California WARNING: Failure to secure workers' co nsatlon veráge Is unlawfu and an employer to crImInal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages v ad Ion 37 r code, mm at and attorney's fees. ' Al C014TRACTOR SIGNATURE V
, []AGENT DATE g /2Jr II
thereby affirm thatl em exempt born Contractors License Law for the following reason:
[J I, as owner of the propertyor'myempbyeeswith wages as their sob compensation, will do the work and the Structure is not intended or offered foisale (Sec. 7044, Business and Profess Ws' Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own emploeas, provided that such improvements am not intended or offered for
sak 11, however, the building or improvement is sold within one yearof completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) foensed pursuant to the Contractor's License Law). V
I emexemptnder Section_- Business and Professions Code for this mason: . V
Ii personally plan to provide the major labor and materials for Construction of the xoposed property improvement. Qfes Ello
2.1 (have lhave riot) signed an application for a building permit for the proposed work.
- 3.1 hash contracted with the following person (firm) to provide the proposed construction (include name address 1phone lcentractors' license number):
4.1 plan to provide poi1ins of the work, but I have hired the following person to coordinate. supervise and provide the major work (include name l address l phone /Contractors! license number):
5. Iwill provide, some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name l address / phone hype of work):,
.'PROPERTY OWNER SIGNATURE - &GENT DATE
Permit Type: BLDG-Residential Application Date: 04/13/2018 Owner: FRANCES CARRILLO
Work Class: Alteration Issue Date: 05/24/2018 Subdivision: CARLSBAD TCT#72-33
Status: Closed - Finaled Expiration Date: 12/03/2018 Address: ' 2510 Navarra Dr, 515
- Carlsbad, CA 92009-7026
IVR Number: 10727
Scheduled Actual - Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
0512512018 05/2512018 BLDG-84 Rough 059171-2018 Failed Andy Krogh Reinspection Complete
Combo(14.24.34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Questions on bathroom shower and smoke No
- alarms -
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical ) No
BLDG-44 No L Rough-Ducts-Dampers
0513012018 0513012018 BLDG-14 059592-2018 Passed Andy Krogh . Complete
FramelSteellBoltingl
Welding (Decks)
BLDG-24 059487-2018 Passed Andy Krogh Complete
RoughlTopout
BLDG-34 Rough 059488.2018 Passed Andy Krogh Complete
Electrical - -
0610512018 06I0612018 BLDG-27 Shower 060001-2018 Passed Michael Collins Complete
Pan/Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Roll in shower Yes
0711112018 07/11/2018 BLDG-Final 063717.2018 Failed Andy Krogh Reinspection Complete
Inspection
Checklist Item - - COMMENTS Passed
BLDG-Building Deficiency Requires grab bar at stairs No
BLDG-Plumbing Final . Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Requires two additional smoke detectors - No
0711212018 07/1212018 BLDG-Final 063880.2018 Passed Andy Krogh - Complete
Inspection
-
Checklist Item COMMENTS - Passed
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
July 12, 2018 Page loll
EsGil
A SAFEbulittompany
DATE: 05/21/2018 , 0 APPLICANT
U JURIS.
JURISDICTION: CitfflSbad
"PLAN CHECK #.: CBR2018-0908 SET: II
PROJECT ADDRESS: 2510 Navarra Drive
PROJECT NAME: Carrillo Residence Remodel
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list.
and should be corrected and resubmitted for a complete. recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant.
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed:
LII EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:/" Telephone #:
Date. contacted: ./" (by: ,t)) Email:
Mail .Telephone Fax In Person
REMARKS: f Plea diiP—sl n heet-A00- as i'iell aslighVswifEiTaiidjriotej
city-Also-Al designersignallsheets-prior to finaj
rppioLvàl:aijprisdiötion
By: Ryan Murphy Enclosures:
r EsGil .
05/14/2018 .
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
EsGil
A SAFEbuIttCompany
DATE: 04/25/2018 U APPLICANT
JURISDICTION: City of Carlsbad
PLAN CHECK #.: CBR2018-0908 SET: 1
PROJECT ADDRESS: 2510 Navarra Drive
PROJECT NAME: Carrillo Residence Remodel
E The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
E The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith havesignificant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
E The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Frances Carrillo
E EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Frances Carrillo Telephone #: (760) 445-7355
Date contacted: A( (bye 1Email: chicarnonkey@gmail.com
QJVIaiIV TeIePhone%7 Fax In Person
III. REMARKS:
By: Ryan Murphy Enclosures:
EsGil
04/16/2018
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
City of Carlsbad CBR2018-0908
04125/2018
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK #.: CBR2018-0908 JURISDICTION: City of Carlsbad
PROJECT ADDRESS: 2510 Navarra Drive
FLOOR AREA: Remodel: 145 sq. ft. STORIES: No change
HEIGHT: No change
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 04/13/2018
DATE INITIAL PLAN REVIEW
COMPLETED: 04/25/2018
FOREWORD (PLEASE READ):
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 04/16/2018
PLAN REVIEWER: Ryan Murphy
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering 'Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process. please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad CBR2018-0908
04/25/2018
PLANS
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and
Fire Departments.
Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
1. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
2. Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 2016 California Residential Code, which adopts the 2015 lRC,
2015 UMC, 2015 UPC and the 2014 NEC. Section R106.1.
FIRE PROTECTION
3. Show locations of permanently wired smoke alarms with battery backup, per
Section R314:
Inside each bedroom.
Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
On each story, including basements.
Such smoke alarm locations shall comply with the following:
They shall be not less than 3' from the door opening of a bathroom.
They shall be at least 20' from a cooking appliance.
They shall be at least 3' from supply registers of heating/cooling
systems.
They shall be at least 3' from the tip of the blade of a ceiling-
mounted fan.
NOTE: When more than one smoke alarm is required to be installed, the
alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the unit.
4. In existing buildings, when alterations, repairs or additions requiring a permit
occur (or when one or more sleeping rooms are added), the dwelling unit shall
be provided with smoke alarms located as required for new dwellings; the
smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms
City of Carlsbad CBR2018-0908
04125/2018
in existing areas need not be interconnected and hard wired where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes
exposing the structure, unless there is an attic, crawl space or basement
available which could provide access for hard wiring and interconnection without
the removal of interior finishes. Section R314.8.1.
5. In dwelling units within which fuel-burning appliances are installed (and in
dwelling units having attached garages), show the locations of permanently wired
carbon monoxide alarms with battery backup, per Section R315:
Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
On each story, including basements.
NOTE: When more than one carbon monoxide alarm is required to be
installed, the alarm devices shall be interconnected in such a manner that the
actuation of one alarm will activate all of the alarms in the unit.
6. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages), the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2.
GENERAL RESIDENTIAL REQUIREMENTS
7. Sleeping rooms shall have a window or exterior door for emergency escape.
Section R310. Please show compliance at existing window in proposed
bedroom.
Windows must have an openable area of at least 5.7 square feet, with the
minimum openable width 20" and the minimum openable height 24".
The bottom of the clear opening shall not exceed 44" above the floor.
Do not measure to the window sill. This generally applies to windows that
have a height of 3' or less. See the figure on the next page to see the
correct method of measurement.
City of Carlsbad CBR2018-0908
04/25/2018
I I fM,
coo
IL
BOTTOM OF,,JJ WINDOW OPENING
I
-- .----•---•• -, . --- •— ' cg - >- -
-•
iO
•
'.4 C) Such openings shall open directly into a public way or a court that opens to a public way (4-sided courts are prohibited).
If such openings occur at a patio, the patio may not be enclosed.
Appendix H, Section AH103.2.
The emergency door or window shall be openable from the inside to
provide a full, clear opening without the use of any keys or toots.
For egress openings at window wells, refer to Section R310.2 for
requirements.
ELECTRICAL
Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
Weather resistant type for receptacles installed in damp or wet locations
(outside).
Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living,
bedrooms, dining, halls, etc.
City of Carlsbad CBR2018-0908
04/25/2018
d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry
areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors,
within 6' of a sink, etc.
10. Per CEC Article 210.11(C)3, note on the plans that bathroom circuiting shall be
either:
A 20-ampere circuit dedicated to each bathroom, or
At least one 20-ampere circuit supplying only bathroom receptacle outlets.
11. Show on the. plans a wall receptacle within 36" of each lavatory in the bathroom.
CEC 210.52(D).
12. Show at least one wall switch-controlled lighting outlet to be installed in every
habitable room; in bathrooms, hallways, stairways, attached garages, and
detached garages with electric power; and at the exterior side of outdoor
entrances or exits. At interior stairways show 3-way switching for lighting outlets
at each floor level where there are six or more steps. CEC Article 210.70(A).
13. All installed luminaires shall be high-efficacy in accordance with ES TABLE
150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in
enclosed luminaires. ES 150.0(k)
14. In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire
shall be controlled by a vacancy sensor.
PLUMBING
15. Specify on the plans: Water conserving fixtures: New water closets shall use no
more than 1.28 gallons of.water per flush, kitchen faucets may not exceed 1.8
GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 2.0
GPM of flow. CPC Sections 407, 408, 411, 412.
16. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of. water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
17. All domestic hot water piping to have the following minimum insulation installed:
1/2" pipe (1/2" insulation); 3/4" pipe (1" insulation): 1" to 1h/2 pipe (14/2" insulation). CPC 609.11 & ES 150.00)
a) Additionally, the 1,4" hot water pipe to the kitchen sink, and the cold-water
pipe within 5' of the water heater both require 1" minimum insulation. ES
150.0(j).
City. of Carlsbad CBR2018-0908
04/25/2018
END OF REVIEW
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to-the plans not resulting from this correction list?
Please indicate:
Yes L3 No L3
The jurisdiction has contracted with EsGil located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ryan Murphy at EsGil. Thank you.
Jurisdiction Code Icb lay Ordinance
1997 UBC Building Permit Fee
1997 UBC Plan Check Fee
Type of Review: LZI Complete Review
ElOther - Repetitive Fee Repeats Hourly
EsGil Fee
I. I
Structural Only
$50151
City of Carlsbad CBR2018-0908
04/25/2018
[DO NOT PAY —THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK #.: CBR2018-0908
PREPARED BY: Ryan Murphy DATE: 04/25/2018
BUILDING ADDRESS: 2510 Navarra Drive
BUILDING OCCUPANCY: R-3
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Remodel 145 city est. - * 6,744
Air Conditioning
Fire Sprinklers
TOTAL VALUE _________
6,744
Comments: Sheet 1 of 1