Loading...
HomeMy WebLinkAbout2510 Navarra Dr; 526; CBR2019-2617; PermitPrint Date: 10/17/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2510 Navarra Dr, 526 BLDG-Residential 2161705130 $2,962.00 Residential Permit Work Class: Alteration Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: (city of Carlsbad Permit No: CBR2019-2617 Status: Applied: Issued: Permit Finaled: Closed· Finaled 09/19/2019 10/01/2019 Inspector: CRenf Final Inspection: 10/17/2019 3:50:07Pr Description: COIN: REPLACE FIRE BOX & CHIMNEY WITH WOOD BURNING FURNACE, LIKE FOR LIKE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Owner: OWNER COIN JULIE A 2510 Navarra Dr, 526 CARLSBAD, CA 92009 SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $91.38 Total Payments To Date: $91.38 Contractor: FIREPLACES PLUS INC 1833 Diamond St, Ste 101 San Marcos, CA 92078-5130 760-752-7789 Balance Due: $0.00 $52.87 $37.01 $1.00 $0.50 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. lf you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ( City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check CBl<Z.0/'l-2.,1+ Est. Value /l' 2 9 kl - PC Deposit Date _f.,_,/:_,/_._1~//L../f-- Suite: !, 'J..(,, APN: 2114 • ('10 ,. :,{-JO CT /Project#:. _________ Lot#:. ____ Fire Sprinklers: yes/ no Air Conditioning: yes/ no 0 Addition/New: _____ .Living SF, ___ Deck SF, ___ Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes@ New Fireplace?~/ No, if yes how many? _/_ D Remodel: _____ SF of affected area Is the area a conversion or change of use ? Yes/ No 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: _______________________________ _ lJ Plumbing/Mechanlcal/Electrical Only: ______________________ _ D Other: ,P'Yb L, o,£,a , APPLICANT (PRIMARY CONTACT) Name: 1UiVC-W' r. Car;,, Address:;H:to N,!\V,>r-!?Ree m,. IJ.v,r: ~-u, City: C/Jki; s i'l tl,D State:.£,i_Zip: 9' l 00!{ Phone: BP,· Q(X, • (!J, '.1 1./(J Email: BBPC s'f'CQ/{\{ W 6, &AJ I, , eo111 DESIGN PROFESSIONAL Name: _________________ _ Address: _______________ _ City: ________ State: ___ Zip: ___ _ Phone: ________________ _ Email: _________________ _ Architect State License: __________ _ PROPERTY OWNER Name: .;:n1/.,ls-A, fotN (1)AVGl:f'T{ffiy Address: 3;10 W. t;:(1 nt <;:t; U,Vl r I C City: Niar:~"'f,: State:-M,¥--Zip: £001 Q Phone: __ · 3!!_ · '711 'i '.I Email: ;;Co .q ,,,-ee,, ttli (ti! f6oTll'l,&,H , CC1M. CONTRACTOR BUSINESS Name: £; Ye/J/=~~J¼_< Address: /!,~~ f2/~m~ <'I _jJ' /~/ Citv'cf'au b1lflt?M5 State:~Zip: ---'<7,,_.;.,,:i:;.;,<¥::...,:;,7£~- Phone: 7¢e-7&;::J -7 7 .r'y Email: g,:/@.vc.z,ob2-c.e'5,(J/~ • Cdl7?:; State License: il/.2 2f5:: Bus. License: lc9r?J(7/0 (Sec. 7031.5 Business and Profe:-;.:;ions Code: Any Oty or County which requires ii permit to construct, alter, improve, demolish or repair any structure, prior to its is~u;ince, al~o requires the applicant for such permit to file a signed stntement that he/she ls licensed pursuant to the pro11isions of the Contractor's License Law {Chapter 9, commending with Seetion 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged e)(emption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602·2719 fax: 760·602-8558 Email: Building@carlsbadca.gov 8--1 Page 1 of2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury Q!!! of the following declarations: □ I have and will maieitaln a certificate of consent to self~insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit iS issued. □ I have and wif! maintain worker's compensation, as required by Section 3700 of the Labor Code, for &erformance of the work for which this permit is issued. My workers' comp_~sation Insurance carrier ayolicy number are: Insurance cy;pz N~e: l '2 J? ,R/ Jd-Q ff" -1 ,R(4. 4 PolicyNo. WR-t:Jt)fl,,;JQ-b ExplrationDate: <97 '/ '/7 □ Certificate of Exemption: I certify that In the periormance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: FaHure to secure workers compensition coverage is unlawful1 and shaH subject an employer to criminal penalties and tMI flnes up to $100,000.00, In lldditlon the to the cost of compensation, damagft as ptO\tHl~d for in Section 370li of the Lahor Cade, interest .tnd attorney's fees. /:7 CONTRACTOR SIGNATURE: ¾~ ~1< _$z □AGENT DATE: y ,//7/1/9 ( OPTION B ): l)WNER-BUILOER DECLARATION: f hereby affirm that I am exempt from Contractors License Law for the fallowing reason: □ l, as ownet of the property or my employees with wages as their sole compensation, will do the work and the !.tructure Is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that sud, improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner~builder will have the burden of proving that he did not bulld or Improve for the purpose of sale). □ I, as owner of the property, am e1<clusively contracting with liumsed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contr<1ctm-'s license Law does not apply to an owner of property who builds or Improves thereon, and COfltracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). □ I arn exempt under Section ________ Business and Professions Code for this reason: 1. l personally plan to provide the major labor and materials for construction of the proposed property improvement, □ Yes □ No 2. 1 (have/ have not) signed an application for a building permit for the proposed work. 3. 1 have contracted with the following person (firm) to provide the proposed construction (indude name address/ phone/ contractors' IICense number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ add res!./ phone/ r;ontractors' license number): 5. ! wH! provide some of the wmk, but I have contracteJ lhjed) the following persons to provide the work Indicated {Include name./ address/ phone/ type of work): en - OWNER SIGNATURE: i ~ . V ~GENT DATE: q-/1.(, ~ / q J:ONSTRUCTION__!,J;NDING AGENCY, ANY: I hereby affirm that there is a construction le Ing agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Address: ___________________ _ ONL V COMPl£TE THE FOLLOWING SECTION FOR NON-RESIDENTIAL l!UllDING PERMITS ONl Y: Is the applkant or future building occupant requited to submit a business plan. acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley"TannerHazardous Substance Account Act.? □ Yes □ No Is the applicant or future bullding occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No ls the farJUty to be constructed within 1,000feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIRCATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLUJTION CONTROL DISTRICT. APPI.ICANT CERTIFICATION: 1 certify that I have read the application and state that the above Information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relarlng to building construction. I hereby authorlle representative of the City of carlsbad to enter upon the above ment1oned property fOf' Inspection purposes. I AlSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE OTY OF CARLSBAD AGAINST" ALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN MiY WAY ACCRUE AGAINSTSAID CITY IN CONSEQUENCE OF THE GRANTING or THIS P£RMIT,OSHA: An OSHA permit ls required for excavations over5'0' deep and demolition or construction of structures over3 stories In height. EXPIRATION: Everv permit !:;sued by the BuHding Official under the provisions of thi5 Code shall expire by limitation and become null and void jf the building or wort{ authorized by such permit is not commenced within 180 days. from the date of such permit or rf the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 da';'S (Section l .4. niform Building Code). B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 '\ • ! ', ' ' l' ~ -, "fi½' ·,> ;'•\, .:, .. ,;,,);~'ERMIT l~SPE¢TlGJ1 HISTORY REPORT'(if;1~2019-2617) : P◊rmit Type: BLDG-Residential Appltcation Date: 09/19/2019 Owner: Worl1; Class: Alteration Issue Date: 10/01/2019 Subdivision: Status. Closed -Finaled Expiration Date; 03/31/2020 Address: IVR Number: 21900 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 09/30/2019 09/30/2019 BLDG-47 Fireplace/Chimney 105720-2019 Checklist Item BLDG-Building Deficiency 10/03/2019 10/03/2019 BLDG-47 Fireplace/Chimney 106300-2019 10/17/2019 10/17/2019 BLDG-Final Inspection October 17, 2019 Checklist Item BLDG-Building Deficiency 107796-2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Cancelled Chris Renfro COMMENTS Passed Chris Renfro COMMENTS Rough frame, duct flue for chimney. Ok to drywall Passed Chris Renfro COMMENTS OWNER COIN JULIE A CARLSBAD TCT#72-33 2510 Navarra Dr, 526 Carlsbad, CA 92009-7026 Reinspection Complete Reinspection Passed No Passed Yes Passed Yes Yes Yes Yes Yes Complete Complete Complete Page 1 of 1 t Fireplaces• l~Plusl 1833 Diamond Street, Suite 101 San Marcos, CA 92078 760. 752. 7789 Phone 760. 752. 7781 Fax www.flreplacesplus.com Contractors License #811295 Date: SEPTEMBER 5, 2019 -REVISED To: BRUCE COIN 2510 NAVARRA DRIVE, UNIT 526 CARLSBAD, CA 92009 Job: COIN Home Phone: 2510 NAVARRA DRIVE, UNIT 526 CARLSBAD, CA 92009 Cell Phone: (856) 906-8240 Email: brucecoin@gmail.com Bid by: Ell CENDEJAS Scope of Work: Homeowner or contractor to remove drywall, brick fascia of the fireplace so fireplace & flue pipe can be demo out. Item# RH-36 DM1036 AK24 FLEX SL348 SL312 SL306 SL315 F5338 Qtt I I I 1 3 2 2 1 I Adjust framing for new RH-36 wood burning fireplace & HOA approval on new termination cap. Fireplaces Plus to demo existing wood burning fireplace & flue pipe. Once framing adjustments have been made. Install Heat-N-Glo RH- 36 wood burning fireplace on one story run with a system height of about 18 feet and possibly off-set with 15 degree elbows on chase install. Pipe mix subject to change at job check or install. Note: HOA is responsible for chase cover & termination caps. We will also need HOA approval to be on roof and we are not responsible if any tiles are damaged In process of un-install & re-install of the fireplaces. Descrif!tion Unit Price Price Royal Hearth 36 Wood Fireplace 36" woodburning radiant w/ 789.00 789.00 traditional brick Original bi-fold glass doors with black trim 409.00 409.00 Outside air kit (1 each) 13.00 13.00 4" x 10' Flex Duct 25.00 25.00 890.00 4 ft. {1220mm) pipe section 141.00 423.00 12" (305mm) pipe section 72.00 144.00 6" chimney section 60.00 120.00 15 Degree elbow (offset and return) 163.00 163.00 Firestop for straight up flue 40.00 40.00 Total Materials 2,126.00 10% Discount (212.60) Labor -Demo Fireplace, Flue Pipe & Disposal 275.00 Labor 625.00 7.75% Tax on materials 148.29 Total proposal $ 2,961.69 This proposal is valid 30 days from the date listed above. If you have any questions regarding the above proposal, please feel free to give us a call. Thank you for your Interest in our business!! OWNER: FIREPLACES PLUS: ___ _ 1 of 1 ' Bruce Coin 2510 Navarra unit 526, Carlsbad, California Inspection date May 07, 2019 Reason for inspection Inspection report requested Level of inspection Level I and parts of Level II Prepared by Cole Richards I C.S.I.A. Certified Inspector #9940 I F.1.R.E. Certified Inspector I 760-436-0086 The Village Chimney Sweep Inc. _&_ THE VILLAGE cnm.'i 5WHP >-1---0 ((Jfl lt,1'1 -21,11 Inspection Address: 2510 Navarra unit 526 Inspection Date: May 07, 2019 Disclaimers and notifications Please note: This report is the exclusive property of The Village Chimney Sweep Inc. and Bruce Coin.If this report is for the required Level II inspection for the sale or transfer of property it is mandatory that full notification of defects be made to the current owner and the potential buyer. Recommendations: Any recommendations are made as a service to our customers and is not a contract or proposal for work for repairs even if an approximate cost is given. If requested a separate repair estimate may be submitted. Grandfathering: When chimney repair is found to be necessary due to potentially hazardous or unsafe conditions, there is no grand fathertng for any portion of the chimney. There is no state or national code that "Grandfather's" any portion of a chimney that represents a potential hazard. Professional chimney inspection: This report is the result of a professional chimney inspection. The report reflects the level of chimney inspection as stated in the report. Everything in this report is factual and supported by the standards represented in the International Residential Building Code 2006, NFPA 211 2016, U.L. and manufacturer installation instructions. The observations in this report are factual and fully supported by documentation, codes and standards. . Inspection level indicated: National Fire Protection Agency (NFPA 211) has 3 levels of inspection. We have added a basic level for estimating purposes. The basic estimating level is restricted to the areas required for a specific estimate request such as an exterior chimney repair. This level does not assess the usability, safety or functionality of the entire structure. This level is a courtesy for the convenience of the client to provide an estimate for the repairs desired. The NFPA 211 level or combination of levels used will be indicated on the report. Visual observation: All aspects of this report are taken from visual observations. Visual observations whether an internal camera system is used or not are limited in scope by the angle of perspective. Hidden flaws could exist that are not available for a visual observation from the angle of the perspective available. Inaccessible areas: There are areas of the chimney, fireplace or appliance that are not available for inspection. These areas include but are not limited to: attic space, hearth support, hearth extension, basement, crawl space, areas concealed between floors and walls and areas that the person inspecting may not have been given access to at the time of the inspection. Roof construction or weather conditions may limit or prohibit roof access. The Customer understands that the Inspector cannot obtain access to certain portions of the fireplace and certain enclosed adjacent areas. The Inspector makes no representations express or implied and will not be responsible in any way whatsoever for deficiencies, improper installation, or improper equipment in inaccessible areas. The findings listed within this report are based on the condition of the appliance system at the time of this inspection and may be limited due to access or type of inspection requested Inspection validity timeframe: We cannot control what happens to this chimney, fireplace, vent, or appliance after we leave the location. Customers may move or construct thin~s that change the clearance to combustibles. Weather, use, misuse, lack of use, vegetation, age and alterations are just some of the factors that can change the condition of the structure. We will not be held responsible for any of these changes that may affect the suitability for use of this chimney, vent or appliance. Suitable for intended use: The purpose of the inspection is to determine reasonable suitability to use this chimney, appliance, vent, or fireplace as the structure was intended when constructed or inspected. A fireplace is intended to be used as an ornamental structure that is designed for short term use and not as a source of heat. Use of a fireplace or other appliance in a way that it is not intended to be used could present a hazard. Measurements: Some of the measurements in this report are approximations. Some of the approximations are used to aid the estimator to write a proposal for work. These approximations are also valuable to help determine proper equipment needed to insure the safety of the chimney professionals doing any of the proposed work. Any inaccuracies in any of these approximations does not invalidate the findings in this report. Copyright The Village Chimney Sweep Inc. Generated with Chimspect Software Page2 , Inspection Address: 2510 Navarra unit 526 Inspection Date: May 07, 2019 Chase #1 Factory-built chimney #1 · Flue blocked or significantly restricted or obstructed by design or construction flaws: Meets industry standards • Chimney cap/ spark arrestor: proper type, condition, installation and required to be free from obstructions: Not accessible Unable to access the roof and therefore unable to evaluate the chimney cap on all units. • Factory-built chimney connection to appliance: Meets industry standards · Proper sizing and suitability for the appliance installed: Meets industry standards · Level of cleanliness of the venting system: Meets industry standards · Chimney Type: Air insulated · U.L. listed factory-built chimney: Yes · General condition: Potential hazard A.(. -~~ . . 'i ..... .. l ,• . '· .. •,:.;.. The chimney is displaying oxidization (rust) and expanded creosote which are both evidence of a chimney fire. In the event of a chimney fire, temperatures in the flue exceed the temperatures the flue was built to handle which can damage the chimney in various ways, the case here being that the flue metal has been chemically changed resulting in a weaker and less heat resistant metal potentially allowing heat to penetrate the metal into the wood framed area. This condition is non-repairable. This chimney should be replaced or remain unused. Copyright The Village Chimney Sweep Inc. Generated with Chimspect Software Page 3 Inspection Address: 251 0 Navarra unit 526 Inspection Date: May 07, 2019 Fireplace #1 • Manufacture, brand, model: Majestic L36 · Owner's manual present and available at the time of inspection?: Yes · Are the mechanical draft systems and damper operable and free of rust and corrosion?: Meets industry standards · Condition of the firebox : Meets industry standards · Condition of the smoke chamber and connection to the flue: Meets industry standards · Are readily accessible parts of factory-built fireplace and chimney free of rust and corrosion?: Potential hazard The chimney is displaying oxidization (rust) and expanded creosote which are both evidence of a chimney fire. In the event of a chimney fire, temperatures in the flue exceed the temperatures the flue was built to handle which can damage the chimney in various ways, the case here being that the flue metal has been chemically changed resulting in a weaker and less heat resistant metal potentially allowing heat to penetrate the metal into the wood framed area. This condition is non-repairable. This chimney should be replaced or remain unused. · Are the fireplace and chimney assembled with appropriate parts including the grate?: Meets industry standards · Configuration (Please indicate the combustible clearances if applicable): Open wood burning Copyright The Village Chimney Sweep Inc. Generated with Chimspect Software Page4 r Inspection Address: 2510 Navarra unit 526 Inspection Date: May 07, 2019 · General condition of the factory-built fireplace: Meets industry standards · Condition of the hearth extension: Meets industry standards · Condition of the fireplace facing: Meets industry standards • Are the factory-built fireplace glass doors and accessories (inserted items) approved?: Meets industry standards Copyright The Village Chimney Sweep Inc. Generated with Chimspect Software Page 5 Installation Manual Installation and Fireplace Setup INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT discard this manual! HEAT&GLO. No one builds a better fire Model(s): RH36 RH42 WOODBURNING FIREPLACE Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recomends HHT Factory Trained or NFI certified professfonals. t1~~~ ll~i¥i¥~- A WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. • DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • DO NOT overtire. Overtiring will void your warranty. • Comply with all minimum clearances to com- bustibles as specified. Failure to comply may cause house fire. A WARNING HOT SURFACES! -'- ,, ,, Glass and other surfaces are hot durin•,..-..,. operation AND cool down. Hot glass will cause burns. • DO NOT touch glass until it is coo,teclllti.l, , NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fireplace. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. • Keep clothing, furnijure, draperies and other flammable materials away. A WARNING Fire Risk. For use with solid wood fuel only. Other fuels may overfire and generate poisonous gases (Le. carbon monoxide). 1 2 3 4 5 ► Safety Alert Key: DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING/ Indicates a hazardous situation which, if not avoided@l!!l! result in death or serious injury. CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Indicates practices which may cause damage to the fireplace or to property. Table of Contents Product Speclflc & Important Safety Information 6 Shrouds A. Fireplace Certification 4 A. Radiation Shield B. Non-Combustible Materials 4 B. Field Constructed Shrouds C. Combustible Materials 4 1. Open Top Shroud Getting Started 2. Mailbox Style Shroud A. Typical Fireplace System 5 3. Roofed Style Shroud B. Design and Installation Considerations 6 7 Finishing 1. Selecting Fireplace Locations 6 A. Finishing Material 2. Locating Fireplace & Chimney 7 B. Hearth Extension, Building and Finishing C. Tools and Supplies Needed 8 1. Hearth Extension 4" or more below D. Inspect Fireplace and Components 8 Fireplace Opening E. Fireplace System Requirements 8 2. Raised Hearth Extension Less Than 4" Below Framing and Clearances Fireplace Opening A. Fireplace Dimensions 9 3. Fireplace Opening and Hearth Extension Flush B. Clearances 10 with Floor Minimum Clearances to Combustibles 10 C. Non-Combustible Sealant Material C. Construct the Chase 11 D. Mantel and Wall Projections D. Frame the Fireplace 12 E. Sidewalls/Surrounds E. Secure and Level the Fireplace 12 8 Fireplace Setup F. Protective Metal Hearth Strips 13 A. Gas Log/Lighter Provision G. Outside Air Kit (optional) 14 B. Wood Burning Inserts Chimney and Termination Requirements 9 Reference Materials A. Chimney Requirements 15 A. Chimney Components B. Offsets/Returns 16 B. Optional Components C. Termination Requirements 17 Chimney Installation A. Typical Chimney System 18 B. Assemble Chimney Sections 19 C. Install Chimney Air Kit 19 D. Secure Offset/Return 20 E. Install Ceiling Firestops 20 F. Install Attic Insulation Shield 21 G. Roof Penetration 22 H. Install Chase/Chase Top 22 I. Termination Cap Requirements 23 J. Install Termination Cap 23 .... ' 2. • Heat & Gia• RH36/RH42 • 4044-194 Installation Manual• Rev O • 09/18 l_.I i 1/f ,_ f"f f' &, 4"' • ' ,,., . ',ii>f ,, '. ~ ' .,!,,;, ' 25 25 25 26 26 27 28 29 29 30 30 31 32 33 33 34 38 Specif1cat1ons RH-36 HEAT&GLO. No one builds a better fire RH-36 41 21" (533] ,,--, •• r t:: Outside Air \ Gas 0 Knockout \ ~ 7-1/2" [191] Left Side View 18-3/4" [476] J 9-1/4" [235] t Please consult the manufacturer's installation manual for all details and requirements before making a final design layout decision. 21-3/8" [543] l 41" (1041] I Top View 00 _j_ 7-1/2" (191] Royal Hearth 36 Wood-burning Fireplace 36 X 18-3/4 > I--0 21" [533] 7-1/2" [191] 36" [914] 14-1/8" t [359] Front View T-: I 39-1/2" [1003] Gas Knockout \ j -~ 9-1/4" [235] 7-1/2" t [191] Right Side View APPLIANCE LOCATION MANTEL PROJECTIONS Combustibje Wa~--<,--•Combustible Decorative Facing 2 x 4 stud wall Stando SUI Joint with n(m-eombustib sealant 1-112;"[38) maxrmum Non-combuslible Decorative Facing such as: Steel. iron, brick, 1ile. concrete, slate, gins. plasters. 12" {305] -----1 1 12' [305] mjnllr!l,lm ~ 6" [1521 min,mum j 7 ff [2134] minimum baseofflrepjace lo ~ing FRAMING DIMENSIONS *39-3/4" [1010] Header MUST NOT be notched! Extra space needed for outside air connection. s•~See install manual for 42" _........_ [203J other details. 1--s,o=,=,---..---[1067] • If interior of chase is drywalled, add thickness to "'Adjust header height for raised floor under fireplace CLEARANCE TO COMBUSTIBLES (attic) insulation -----------, Attic nsutaUon Sh'1eld MANTEL LEG/WALL PROJECTIONS 12" [305] HEARTH EXTENSIONS 4"[102)=mc... bet.,...nbollomof ''~°""'"'9""° ,u~ooo o1~ .. r!h•- HEAT&GLO No one builds i!I better fire 12" [305 :! 48' }r J 1219] o· to level of standoffs HEARTH EXTENSION CONSTRUCTION Continuous, non- combustible sealant , Fireplace ::· Opening ' 1/2'' Micore Heartti T~s stone or other 1 Extension {or non-Combustible material\ 'fiL.....__ See Install Manual, { t ,._ 1---1_.minimum equivalent insulation) . /' -yjt ~ 4" [102] "-I-_._.... --I:--,:·· ! Floor constructed of wood or other combustible material = 2" [51 ) of the Protective Metal Hearth Strip iS required under the front of the fireplace PRODUCT LISTING CODES Product informatic'l pr01,:cc-:1 :.o ror cor-iolete and is Sl:b;ect to ::,•argc without notic~. ProduC'.: in~:alla:·nn Must adhere strictly to 1nstrJ~t·.oris accompanying oroduct to avo,d t 1sk of frre anci potential inJUry . us UL 127 CAN ULC-S6l0 .Add1t1onal mformat1on can be found onl,ne at wv1w.!"'i-:'!-atnglo.com 4 briJnd of HeiJr(h & Home Technologies 'Inc Lakeville, MN Phone: (800) 927-6841 Web: www.heatnglo.com ' •JBtf THULMAN® FIREPLACE & CHIMNEY INSTALLATION INSTRUCTIONS Majestic Thulman fireplaces have the following guarantees, approvals, recommendations or listings: • 62-26R /Building Of!icials Conference of America, fnc.) 1NTERNA.Tl0NAL CONFERENCE OF BUILDING OFFICIALS REPORT NO. 1581. /'fo, 70JI (Southern Buitdin11: Code Con,:res.sl Look for the U.L Label on the Fireplace Listed under one or more of the following U. s. Patents: 263472D; 2856837; and 2821975. Model L28A-OPEN FRONT Models L36A and L42A-OPEN FRONT Models L36AR and L42AR -OPEN RIGHT END Models L36AL and L42AL-OPEN LEFT END READ INSTRUCTIONS CAREFULLY; REFER TO YOUR MODEL NUMBER LOCAL CODES: Local Building Codes should be consulted in all cases as to the particu- lar requirements concerning the installation of factory-built fireplaces. Majestic Thulman Fireplaces are intended for use in accordance with Standard NFPA #211 of the National Fire Protection Association. CLEARANCES: Any of these models may be ptaced directly on a combustible floor, against a combustible wall or raised on a wooden platfonn without clearance from combustible construction. Framing members may be placed directly against the side and back of the fireplace. Combustible floors must be protected at front and sides of openings, as shown below. Combustible walls, at right angles and within 40"of fireptar...e opening, must be protected as shown·below. L28A, L36A sections require 211 clearance, and L42A sections require 111 clearance to combustibles. Galvanized Iron to be used on the floor under the crack. CAUTION: Seal crack betwee11 -fireplace and extencte<l hearth. 9dMAX. ALLIIODELS ADDITIONAL FLU£ SUP!'Jlf!"l'. !\EOUIAED AT 411675 FROM FLOOR. 0 TSIDE PIP£ DIA... ' 1Slt2" FOR L2SA A L56A µptf_~ 16" FOR L4U UNrTS ':) 'C,. ' USE NOtf.COMB\ISTl8t..E MATERIAi. ON SMADEOAfl!AS •TO SIOE 1--...,.. t;:::~;u~'::,--'--1:t----',, O"TO FLOOR ... f'ROT!CT ADJACENT . : ' COM8USTIILE SIDE WALL WITHJN 4-o" ' 'cif F.P. OPENING WITH MAJESTIC SP40 INSlJ LA TED WALL PANEL t PIECI! IXTENOEO HEARTH EHHRL(2f'IECEll'OII L36ARORAL EH42RL(2PIECEJFOR L42AA OFI AL 11_...._ __ SIDE WALL RIGHT OR LEFT OPEN-END FIREPLACE O"TO SIDE "TO l'l.000 01,lt 20,, • 11,11 ----------· DIMENSIONS FOR FRAMING: I I I ' FRONT 1----36•--..< FRONT 53" FRONT ·~ ' See Framing Instructions on Paga 5. Model L28A '°;' .t --;::r- cuoe: ' ., '. ~ . Page2 CORNER INSTALLATION . 1/ . ( .. .(.(!_,,r-' Models L36AR & L36AL (shown) T 52" l SIDE ~ r + -'-- I ,A? I F 1'Yl I v 1 )/1 24" "'---0 --I---'-' _J_ -.; // . .J 'f:, ~ µ!_-36"---i 1-'J..----....r-- 41" FRONT J:. PLAN ~l 42" 47J/, FRONT "· .--.· .·.~ •