Loading...
HomeMy WebLinkAbout2510 Navarra Dr; 516; CBR2019-2618; PermitPrint Date: 10/17/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2510 Navarra Dr, 516 BLDG-Residential 2161705124 $3,486.00 Residential Permit Work Class: Alteration Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: (City of Carlsbad Permit No: CBR2019-2618 Status: Applied: Issued: Permit Fina led: Closed -Finaled 09/19/2019 09/27/2019 Inspector: CRenf Final Inspection: 10/17/2019 3:50:20PI Description: TRUESDALE: REPLACE FIREBOX & CHIMNEY WITH WOOD BURNING FURNACE, LIKE FOR LIKE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Owner: TRUST TRUESDALE BRENDAL 2510 Navarra Dr, 516 CARLSBAD, CA 92009 SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $106.46 Total Payments To Date: $106.46 Contractor: FIREPLACES PLUS INC 1833 Diamond St, Ste 101 San Marcos, CA 92078-5130 760-752-7789 Balance Due: $0.00 $61. 74 $43.22 $1.00 $0.50 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as '"fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov {'Cityof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check Cf3g2rJJ f ... zt. \-~ Est. Value ~34B6 PC Deposit--------- Date ---+'f.~/l~f b'-'-1-1-1-- Job Address as:tD Na V(>.. ~ \o'Yiv:r • APN: ________ _ yes/ no j(Addition/New: _____ ,Living SF, ---=-Deck SF, ___ Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes,® New Fireplace?c,),' No, if yes how many? _L D Remodel: ____ SF of affected area Is the area a conversion or change of use? Yes/ No 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ___________ _ □ Solar: ___ KVil, ___ Modules, Mounted: Roof/ Ground , Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ----------------------------------- ;:_] Plumbing/Mechanical/Electrical Only: _______________________ _ □ Other: p 41d-d La?r d I DESIGN PROFESSIONAL Name: ________________ _ Address: _______________ _ City: _______ State: ___ Zip: ___ _ Phone: _______________ _ Email: ________________ _ Architect State License: __________ _ CONTRACTOR BUSINESS Name: F~~4 ~4 Addre~:tJ=Z,, -#1;: !:?::/ City~J1 Jf}IJ£c-#, State: cXJ Zip: q,zf) Zf' Phone: 7(ta-tjf..,., ZZ T'Z Email: .eµ<Z~Be--1/i,Ptu, -"'4i!;l State Ucense: RI/= Bus. License: iJ3. r,,'.1/Q (Sec. 7031.S Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to Its lssua nee, al so req ulres the applicant for such permit ID file a signed st;rtement that he/she is licensed pursuantto lhe provisions of the Contractor's Lii:ense law !Chapter 9, commending with Section 7000 of DMsion 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis fMlhe alleged exemption. Any lllolatlon of Section 7031,5 by any applicant for a permit subjects the applicant to a cl'III penalty of not more than five hundred dollars ($S00)). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury Q!l£ of the following declarations: □ I have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. □ I have and will malntiln worker's compensation, as required by Section 3700 of the Labor Code, for ~erformance of the work for which this permit Is Issued. My workers' compensation Insurance carrier and P.Olicy number are: Insurance ~zv: me: C,Ep / -9? tBi,,tl:. Jf;) W.:::z Policy No. u(4 -001 ~JO -lJ t/' E,iplratlon Date: t:J7 / ~ i?'Q • □ Certificate of Exemption: I certify that in the performance of the work for which this permit Is Issued, I shall not employ any person In any manner so as to be come subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation cover111e Is unlawful, and shall subject an employer to criminal penalties and chill fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, Interest and attomey's fees. CONTRACTORSIGNATURE: _ .... ~~,---'~.-;::.,o::::.=.a:::;.,j.,..~,-.,;?"""'11!~-.-----~GENT DATE: ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I om exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License L.1w does not apply to an owner of property who builds or Improves thereon, and who does such work himseH or through his own employees, provided that such improvementsare not Intended or offered for sale. ff, however, the building or improvement is sold within one year of completion, the owner-builder wlll have the burden of proving that he did not build or Improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section _______ Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I [have/ have not) signed an application for a build Ing permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (Include name address/ phone/ contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name/ address/ phone/ contractors' license number): S. I will provide some of the work~ have contr~d (hl•~r11 A-follnwln11: Persons to P(OVide t,lie work Indicated (Include name/ address/ phone/ type of work): OWNER SIGNATURE: i.-< ••• -· _□AGENT DATE: 'f-lJ-15 ·v - CONSTRUCTION LENDING AGENCY, IFANY: I hereby affirm that there Is a construction lending agency for the performance of the work this permit Is issued (Sec. 3097 Ill Civil Code). Lender's N.ime: \~Jl"ol\Q. Lender's Address: ___________________ _ ~W' ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 2SS05, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000feet of the outer boundal)' of a school site? □ Yes □ No IF ANV OF TI-IE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCV MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVIO:S AND lHE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building constructlo n. 1 hereby authorize representative of the Qty of Carlsbad to enter upon the above mertioned property for inspection p11poses.1 Al.SO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE OlY OF CARLSBAD AGAINST ALL UABIUTIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY tN CONSEQUENCE OF THE GRANTING OF TI-11S PERMIT.OSHA: An OSHA permit is nequired for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of2 ····~ .. ----- Email: Building@carlsbadca.gov Rev. 06/18 I I ,,-~~,~ 1 1 f ' ' I ' " ' , . , -P&RMl1"'1NSPECTION 1-tlSIORY REPORT (CBR2019--2618) f ' 1'\ ' ( > Pnrmit Type: BLDG-Residential Application Date: 09/19/2019 Owner: TRUST TRUESDALE BRENDA L Work Class: Alteration Issue Date: 09/27/2019 Subdivision: CARLSBAD TCT#72-33 Status: Closed -Finaled Expiration Date: lVR Number: 03/31/2020 21901 Address: 2510 Navarra Dr, 516 Carlsbad, CA 92009-7026 .. _..., ____ .. ___ ---·----·•··•·· ... ·•···•··-···-'· _ .. ., ... ,_.""·•······--· .. ·•··-··-···---···-···-"··-··-·····-··------·---------_-___ -..:...:::----=========--- Scheduled Actual . Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 09/30/2019 09130/2019 BLDG-47 105719-2019 Fireplace/Chimney Checklist Item BLDG-Building Deficiency 10/03/2019 10/03/2019 BLDG-47 106299-2019 Fireplace/Chimney 10117/2019 10/17/2019 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 107795-2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final cancelled Chris Renfro COMMENTS Passed Chris Renfro COMMENTS Rough frame, duct flue for chimney. Ok to drywall Passed Chris Renfro COMME.NTS Re inspection Complete ---- Re inspection Complete Passed No Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes ... ··--·---· ·---········--·· ······•·--·•······---··---•··•····· ... •-·-·-·-··•"·-------·----··--··-----------· -----·•·---~--·--·----·-·- October 17, 2019 Page 1 of 1 ' Brenda Truesdale 2510 Navarra unit 516, Carlsbad, California Inspection date May 06, 2019 Reason for inspection Inspection report requested Level of inspection Level I and parts of Level II Prepared by Cole Richards I C.S.I.A. Certified Inspector #9940 I F.I.R.E. Certified Inspector I 760-436-0086 The Village Chimney Sweep Inc. _a_ THE VILLAGE tHlliMEY swm• ' • Inspection Address: 2510 Navarra unit 516 Inspection Date: May 06, 2019 Disclaimers and notifications Please note: This report is the exclusive property of The Village Chimney Sweep Inc. and Brenda Truesdale.If this report is for the required Level ll inspection for the sale or transfer of property it is mandatory that full notification of defects be made to the current owner and the potential buyer. Recommendations: Any recommendations are made as a service to our customers and is not a contract or proposal for work for repairs even if an approximate cost is given. ff requested a separate repair estimate may be submitted. Grandfathering: When chimney repair is found to be necessary due to potentially hazardous or unsafe conditions, there is no grand fathering tor any portion of the chimney. There is no state or national code that "Grandfather's" any portion of a chimney that represents a potential hazard. Professional chimney inspection: This report is the result of a professional chimney inspection. The report reflects the level of chimney inspection as stated in the report. Everything in this report is factual and supported by the standards represented in the International Residential Building Code 2006, NFPA 211 2016, U.L. and manufacturer installation instructions. The observations in this report are factual and fully supported by documentation, codes and standards. Inspection level indicated: National Fire Protection Agency (NFPA 211) has 3 levels of inspection. We have added a basic level for estimating purposes. The basic estimating level is restricted to the areas required for a specific estimate request such as an exterior chimney repair. This level does not assess the usability, safety or functionality of the entire structure. This level is a courtesy for the convenience of the client to provide an estimate for the repairs desired. The NFPA 211 level or combination of levels used will be indicated on the report. Visual observation: All aspects of this report are taken from visual observations. Visual observations whether an internal camera system is used or not are limited in scope by the angle of perspective. Hidden flaws could exist that are not available for a visual observation from the angle of the perspective available. Inaccessible areas: There are areas of the chimney, fireplace or appliance that are not available for inspection. These areas include but are not limited to: attic space, hearth support, hearth extension, basement, crawl space, areas concealed between floors and walls and areas that the person inspecting may not have been given access to at the time of the inspection. Roof construction or weather conditions may limit or prohibit roof access. The Customer understands that the Inspector cannot obtain access to certain portions of the fireplace and certain enclosed adjacent areas. The Inspector makes no representations express or implied and will not be responsible in any way whatsoever tor deficiencies, improper installation, or improper equipment in inaccessible areas. The findings listed within this report are based on the condition of the appliance system at the time of this inspection and may be limited due to access or type of inspection requested Inspection validity timeframe: We cannot control what happens to this chimney, fireplace, vent, or appliance after we leave the location. Customers may move or construct things that change the clearance to combustibles. Weather, use, misuse, lack of use, vegetation, age and alterations are just some of the factors that can change the condition of the structure. We will not be held responsible for any of these changes that may affect the suitability for use of this chimney, vent or appliance. Suitable for intended use: The purpose of the inspection is to determine reasonable suitability to use this chimney, appliance, vent, or fireplace as the structure was intended when constructed or inspected. A fireplace is intended to be used as an ornamental structure that is designed for short term use and not as a source of heat. Use of a fireplace or other appliance in a way that it is not intended to be used could present a hazard. Measurements: Some of the measurements in this report are approximations. Some of the approximations are used to aid the estimator to write a proposal for work. These approximations are also valuable to help determine proper equipment needed to insure the safety of the chimney professionals doing any of the proposed work. Any inaccuracies in any of these approximations does not invandate the findings in this report. ""· ( .,. L.;opyngm I ne v11Iage L.;nimney :;weep Inc. Generated with Chimspect Software Page 2 Inspection Address: 2510 Navarra unit 516 Inspection Date: May 06, 2019 Chase #1 Factory-built chimney #1 • Flue blocked or significantly restricted or obstructed by design or construction flaws: Meets industry standards • Factory-built chimney assembled with appropriate parts: Meets industry ~tandards • General condition: Meets industry standards • U.L. listed factory-built chimney: Yes • Chimney joint security and stability: Does not meet industry standards Slight disconnection at offset 8 feet from flue opening. Recommend having flue reconnected before use. • Installation, support and condition of offsets in the flue: Does not meet industry standards • Proper sizing and suitability for the appliance installed: Meets industry standards • Level of cleanliness of the venting system: Meets industry standards • Chimney Type: Air insulated Fireplace #1 • Configuration (Please indicate the combustible clearances if applicable): Open wood burning • Manufacture, brand, model: Majestic L36 • Are readily accessible parts of factory-built fireplace and chimney free of rust and corrosion?: Meets industry standards • Are the mechanical draft systems and damper operable and free of rust and corrosion?: Meets industry standards • Owner's manual present and available at the time of inspection?: Yes · Condition of the firebox : Meets industry standards • Condition of the smoke chamber and connection to the flue: Meets industry standards • General condition of the factory-built fireplace: Meets industry standards Inspection Address: 2510 Navarra unit 516 inspection Date: May 06, 2019 Copyright The Village Chimney Sweep Inc. Generated with Chimspect Software Page3 · Do the clearances around the factory built fireplace meet the manufacturers recommendations including the hearth extension?: Paper should be removed before fireplace is used. Gap should be sealed to prevent heated gases from rising into combustible framed areas. · Condition of the hearth extension: Meets industry standards · Condition of the fireplace facing: Meets industry standards · Are the factory-built fireplace glass doors and accessories (inserted items) approved?: Meets industry standards Inspection Address: 251 0 Navarra unit 516 Inspection Date: May 06, 2019 Copyright The Village Chimney Sweep Inc. Generated with Chirnspect Software Page4 Findings and conclusions Reconnecting the pipe and removing combustible material from the above the face of the firebox is to be done before the chimney could be considered in usable condition. Copyright The Village Chimney Sweep Inc. Generated with Chimspect Software Page 5 l Fi~eplaces ~ l~Plusl 1833 Diamond Street, Suite 101 San Marcos, CA 92078 760. 752. 7789 Phone 760.752.7781 Fax www.flreplacesplus.com Contractors License INl11295 Item# RH-36 Date: September 4, 2019 To: BRENDA TRUESDALE 2S10 NAVARRA ST, UNIT S16 CARLSBAD, CA 92009 Job: TRUESDALE 2510 NAVARRA ST, UNIT S16 CARLSBAD, CA 92009 Home Phone: (760) 445-961S Cell Phone: (760) 814-7121 Email: bltelvise@yahoo.com Bid by: ELI CENDEJAS Scope of Work: Homeowner or contractor to remove the tile on face existing fireplace, open up the wall about 62" from base of the fireplace so we can pull old fireplace out and adjust framing for new Heat-N-Glo RH-36 wood burning fireplace. Fireplaces Plus to demo existing fireplace, flue pipe and install Heat-N-Glo RH-36 wood burning fireplace on two story run and off-set with 30 degree off-set on chase install. Pipe mix subject to change at job check or install. Note: HOA is responsible for chase cowr & termination caps. We will also need HOA approl/OI to be on roof and we are not responsible if any tHes are damaged in process of un-instaN & re-install of tile fireplaces. Qty Description Unit Price Price l Royal Hearth 36 Wood Fireplace 36" woodburning radiant w/ 789.00 789.00 tra ditiona I brick DM1036 AK24 FLEX 1 Original bi-fold glass doors with black trim 1 Outside air kit (1 each) l 4" x 10' Flex Duct 409.00 409.00 13.00 13.00 25.00 25.00 .·· ..................... -. ............ -Total for.flue Pll!.e. and c.aP ........... ------........... ________ _ 1~:!·1 ISL348 !sL336 .SL318 !SL312 !sL306 !SL330 'FS338 5 4 ft. (1220mm) pipe section 1 36" (915mm) pipe section 1 18" (455mm) pipe section 2 12" (305mm) pipe section 2 6" chimney section 1 30 Degree elbow (offset and return I 2 Firestop for straight up flue Total Materials 10% Discount Labor -Demo Fireplace, Flue Pipe & Disposal Labor 7.75% Tax on materials Total proposal This proposal is valid 30 days from the date listed above. 141.00 119.00 80.00 72.00 60.00 183.00 40.00 If you have any questions regarding the above proposal, please feel free to give us a call. Thank J10U for your interest In our busifleSSII OWNER: FIREPlACES PLUS: ___ _ 80.00 144.00 120.00 183.00 80.00 2,667.00 (266.70) 275.00 625.00 186.02 $ 3,"86.32 1 of 1 NW Installation Manual·i\ _· ···,r·, -•. Installation and Fireplace Setup SEP 2 ; 20)§ INSTALLER: Leave this manual with party responsible for use and 'operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT discard this manual! HEAT&GLO .. No one builds a better fire Model(s): RH36 RH42 WOODBURNING FIREPLACE Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recomends HHT Factory Trained or NFI certified professionals. ~~~~ lil~l~~i~- F<fi.{,f. A WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. • DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • DO NOT overtire. Overfiring will void your warranty. • Comply with all minimum clearances to com- bustibles as specified. Failure to comply may cause house fire. A WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fireplace. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. • Keep clothing, furniture. draperies and other flammable materials away. A WARNING Fire Risk. For use with solid wood fuel only. Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide). Heat & Gia• RH36/RH42 • 4044-194 lnsIDltluO:elli)'l-2 c, Ii ~{,1Key: 1 2 3 4 5 ► DANGER! Indicates a hazardous situation which, if not avoided ~ result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. CAUTION/ Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Indicates practices which may cause damage to the fireplace or to property. Table of Contents Product Specific & Important Safety Information 6 Shrouds A. Fireplace Certification 4 A. Radiation Shield B. Non-Combustible Materials 4 B. Field Constructed Shrouds C. Combustible Materials 4 1. Open Top Shroud Getting Started 2. Mailbox Style Shroud A. Typical Fireplace System 5 3. Roofed Style Shroud B. Design and Installation Considerations 6 7 Finishing 1. Selecting Fireplace Locations 6 A. Finishing Material 2. Locating Fireplace & Chimney 7 B. Hearth Extension, Building and Finishing C. Tools and Supplies Needed 8 1. Hearth Extension 4" or more below D. Inspect Fireplace and Components 8 Fireplace Opening E. Fireplace System Requirements 8 2. Raised Hearth Extension Less Than 4" Below Framing and Clearances Fireplace Opening A. Fireplace Dimensions 9 3. Fireplace Opening and Hearth Extension Flush B. Clearances 10 with Floor Minimum Clearances to Combustibles 10 C. Non-Combustible Sealant Material C. Construct the Chase 11 D. Mantel and Wall Projections D. Frame the Fireplace 12 E. Sidewalls/Surrounds E. Secure and Level the Fireplace 12 8 Fireplace Setup F. Protective Metal Hearth Strips 13 A. Gas Log/Lighter Provision G. Outside Air Kit (optional) 14 B. Wood Burning Inserts Chimney and Termination Requirements 9 Reference Materials A. Chimney Requirements 15 A. Chimney Components B. Offsets/Returns 16 B. Optional Components C. Termination Requirements 17 Chimney Installation A. Typical Chimney System 18 B. Assemble Chimney Sections 19 C. Install Chimney Air Kit 19 D. Secure Offset/Return 20 E. Install Ceiling Firestops 20 F. Install Attic Insulation Shield 21 G. Roof Penetration 22 H. Install Chase/Chase Top 22 I. Termination Cap Requirements 23 J. Install Termination Cap 23 ~ " \ .. ""c:· ' • r;. _ Heat & Gia • Rrj36/RH42 • 4-9. 44-194 Installation Manual • Rev O • 09/18 'J ~ , ,. • I ~ f'!:._ ' .. i . l -~• : 1 :..,, . fi-', ----------·---·- 25 25 25 26 26 27 28 29 29 30 30 31 32 33 33 34 38 > 1--0 ' ' Specifications RH-36 HEAT&GLO. Please consult the manufacturer's installation manual for all details an d requirements before making a final design layout decision. Royal Hearth 36 No one builds a better fire Wood-burning Fireplace MODEL RH-36 FRONT WIDTH Actual Framing Actual Framing Actual Framing Actual Framing 41 42 23-3/4 42 39-1/2 39-3/4 21-3/8 21-1/2 . .._ ' SEP 2 5 2019 23-3/4" [603] -1 7-3/8" 11-7/8" ~[187] 302 - ---Etlf---ll--tllit---- 21 -3 / 8" , 'ID [5431 --C 'J ----=-~---'~~.=.....l Outside Air \ Gas Q Knockout \ 21" (533) 18-3/4" [476) 9-1/4" .. [235) i---7-112" --l- [191 J I 41" (1041) ---1 Top View ......-'---->---L-'---=-=--=~---'--'--.L......>~ _L 36" [914) Front View 7-1/2" [191) 21" [533] 7-1/2" [191) -l 14-1/8" [359) T~ 39-1 /2" [1003) H ■, <Doro1I Gas Knockout \ 7-1/2" (191) 36 X 18-3/4 I 9-1/4" (235) I I Left Side View Right Side View Additional information an be found onhne at www.heatnglo.com or www.f,replaces.com <> '-'p Q Sper1f1cat1ons RH-36 APPLIANCE LOCATION In an exterior chasr or projecting into a garage 12"[305) minlmumfmm nreplace opening to perpendicular wall Along a wall i I-50" 11 2101--l-=1 f-42" 110671-H MANTEL PROJECTIONS Combustible Wal Standoff Non-combustible Decorative Facing such as: Steel, Iron, brick, tile, concrele, state, glass, plasters. Combustible Decorative Facing 12" 1305] -----j ---r 6" 1152) minimum I I 12'. jJ05J mtmmum 1:i~f~~ base of fireplace toce•in9 Measured from top of fireplace opening MANTEL LEG/WALL PROJECTIONS 12" [305] HEARTH EXTENSIONS ·• [102] l'flll'IIAlCJffl 001we,enbol'\oln01 fir•~~ opining and wrftioe o!heartheueotJor, 12" 1305] FRAMING DIMENSIONS •39.3/4" [1010] Header MUST NOT be notched! Extra space needed for outside air connection. a•~See install manual for 42" __.., [203] other details. ---..,.1c-=-~ [1067] • If interior of chase is drywalled, add thickness to • Adjust header height for raised floor under fireplace CLEARANCE TO COMBUSTIBLES u Q) :g~ ~ 48' I 1219) <.) HEARTH EXTENSION CONSTRUCTION Continuous, non-Fireplace combustible sealant Opening 1/2" Micore Hearth Tile stone or other •~ Extension (or no~~ombustible material equivalent insulation) /I '--------r4· [102] See Install Manual ./ l l minimum "-► ::: ... ' •. :. '·.·.;'. I F l I= 2" [51] of the Protective Floor constructed of wood or Metal Hearth Strip is required other combustible material under the front of the fireplace PRODUCT LISTING CODES Product information provided is not complete and is subJect to change without notice. Product installation must adhere strictly to 1nstruct1ons accompanying product to avoid risk of fir and potential iniury. us UL 127 CAN ULC-S610 Add1t1onal information can be found online al www.heatnglo.com HEAT&GLO. A bi.and of Hearth & Home Technolo91es-... J:,c. c@ususno No one builds a batt9r fire Lakeville. MN Phone: (800) 927-6841 Web: www.heatnglo.com W":J, HrK,/RH-36_tJ511 Majestic Thulman fireplaces have t he following guarantees, approvals, recommendations or listings: 62·26R INTERNATIONAL CONfERENCE OF BUILDING OFFICIALS REPORT NO. 1581. (Buildi,g Officials Cor.ference of ~meiica, rnc.) No. 7011 (Southern BuildlnR Code C~ngre.sl Look for the U.L. Label on the Fireplace Listed under one or more of the following U. S. Patents: 2634720, 2856837; and 2821975. I" CLEARANCE TO COMBUSTIBLES FOR L42A 2• CLEARANCE TO C0r,1BUSTIBL£S FOR L36A 0UTSI 0£ Pl PE DIA. Model L28A-OPEN FRONT 0\c{ INSTALLATION INSTRUCTIONS Models L36A and L42A -OPEN FRONT Models L36AR and L42AR -OPEN RIGHT END Mod·els L36Al and L42AL -OPEN LEFT END READ INSTRUCTIONS CAREFULLY; REFER TO YOUR MODEL NUMBER LOCAL CODES: Local Building Codes should be consulted in all cases as to the particu- lar requirements concerning the installation of factory-built fireplaces. Majestic Thulman Fireplaces are intended for use in accordance with Standard NFPA #211 of the National Fire Protectron Association. CLEARANCES: Any of these models may be placed directly on a combustible floor, against a combustible wall or raised on a wooden platfonn without clearance from combustible construction. Framing members l'l'.ay be placed directly against the side and back of the fireplace. Combustible floors must be protected at front and sides of openings, as shown below. Combustible walls, at right angles and within 40"of fireplace open ing, must be protected as shown·below,. L28A, L36A sections require 2" clearance, and L42A sections require 111 clearance to combustibles. Fireplace Seal Crack Extended Hearth Galvanized Iron to be used on the floor under the crack. CAUTION: Seal crack between firep l ace and extended hearth. n 9o'MAX . ,A.LL IIOOE!.S AOOITJO~AL FLUE SIJPP~T REOUIRED AT 4:1 &75' l"ROM FLOOA. I" Cl.EARP.ta TO COM9UST1BL£S FOR L42A 13112" FOR 1.28.11 81 L56A UNITS 16" FOR L42.A UNITS USE NOH--COMBIJS"fl MATERIAL ON ( StfAOl';O AR A 2" Cl.£ARANCE TO C~FORLIIA AMO l.3U I USE NON-COMBUSTMIU! MATPlilj. Of! SIIAOf0 AAEAS PROTECT ADJACENT COMBUSTIBlE SIDE WAU WITHIN 4-0" Of F.P. OPENING WITH MAJESTIC SP◄O INSULATED WALL PANEL I· See Framing Instructions on Paga 5. Model L28A ~ J..---3a•--..; i--24'--l FRONT SIDE J T 52" kl 36' :_ L ';f-53 . 7'' 46" · I 1-124•~ FRONT SIOE/;& T '-----42"--...i __ j ~6" 6' !====-=-==-=5=3•==-==--==-=:...=_= _= -..;::r_r_ ~-t.· 1 l--2411;'--4 1)1 gc: FRONT CORNER tNSTALLATION . 'IL L .(t,, Models L36AR & L36AL (shown) T 52" l SIDE 24" T l _J__ ~r _, l /t 24" 0 _ ___,___, _J_ i-;;..--36" 41"-- FRONT 1-4+--42" 47Jt; FRONT 3(::;-·