HomeMy WebLinkAbout2510 Navarra Dr; 516; CBR2019-2618; PermitPrint Date: 10/17/2019
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2510 Navarra Dr, 516
BLDG-Residential
2161705124
$3,486.00
Residential Permit
Work Class: Alteration
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
(City of
Carlsbad
Permit No: CBR2019-2618
Status:
Applied:
Issued:
Permit
Fina led:
Closed -Finaled
09/19/2019
09/27/2019
Inspector: CRenf
Final
Inspection: 10/17/2019 3:50:20PI
Description: TRUESDALE: REPLACE FIREBOX & CHIMNEY WITH WOOD BURNING FURNACE, LIKE FOR LIKE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Owner:
TRUST TRUESDALE BRENDAL
2510 Navarra Dr, 516
CARLSBAD, CA 92009
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $106.46 Total Payments To Date: $106.46
Contractor:
FIREPLACES PLUS INC
1833 Diamond St, Ste 101
San Marcos, CA 92078-5130
760-752-7789
Balance Due: $0.00
$61. 74
$43.22
$1.00
$0.50
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as '"fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
{'Cityof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check Cf3g2rJJ f ... zt. \-~
Est. Value ~34B6
PC Deposit---------
Date ---+'f.~/l~f b'-'-1-1-1--
Job Address as:tD Na V(>.. ~ \o'Yiv:r • APN: ________ _
yes/ no
j(Addition/New: _____ ,Living SF, ---=-Deck SF, ___ Patio SF, ___ Garage SF
Is this to create an Accessory Dwelling Unit? Yes,® New Fireplace?c,),' No, if yes how many? _L
D Remodel: ____ SF of affected area Is the area a conversion or change of use? Yes/ No
0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ___________ _
□ Solar: ___ KVil, ___ Modules, Mounted: Roof/ Ground , Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No
Panel Upgrade: Yes/ No
D Reroof: -----------------------------------
;:_] Plumbing/Mechanical/Electrical Only: _______________________ _
□ Other: p 41d-d La?r d I
DESIGN PROFESSIONAL
Name: ________________ _
Address: _______________ _
City: _______ State: ___ Zip: ___ _
Phone: _______________ _
Email: ________________ _
Architect State License: __________ _
CONTRACTOR BUSINESS
Name: F~~4 ~4 Addre~:tJ=Z,, -#1;: !:?::/
City~J1 Jf}IJ£c-#, State: cXJ Zip: q,zf) Zf'
Phone: 7(ta-tjf..,., ZZ T'Z
Email: .eµ<Z~Be--1/i,Ptu, -"'4i!;l
State Ucense: RI/= Bus. License: iJ3. r,,'.1/Q
(Sec. 7031.S Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to Its
lssua nee, al so req ulres the applicant for such permit ID file a signed st;rtement that he/she is licensed pursuantto lhe provisions of the Contractor's Lii:ense law
!Chapter 9, commending with Section 7000 of DMsion 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis fMlhe alleged
exemption. Any lllolatlon of Section 7031,5 by any applicant for a permit subjects the applicant to a cl'III penalty of not more than five hundred dollars ($S00)).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
B-1 Page 1 of 2 Rev. 06/18
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury Q!l£ of the following declarations:
□ I have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
□ I have and will malntiln worker's compensation, as required by Section 3700 of the Labor Code, for ~erformance of the work for which this permit Is Issued.
My workers' compensation Insurance carrier and P.Olicy number are: Insurance ~zv: me: C,Ep / -9? tBi,,tl:. Jf;) W.:::z
Policy No. u(4 -001 ~JO -lJ t/' E,iplratlon Date: t:J7 / ~ i?'Q •
□ Certificate of Exemption: I certify that in the performance of the work for which this permit Is Issued, I shall not employ any person In any manner so as to be come
subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation cover111e Is unlawful, and shall subject an employer to
criminal penalties and chill fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
Interest and attomey's fees.
CONTRACTORSIGNATURE: _ .... ~~,---'~.-;::.,o::::.=.a:::;.,j.,..~,-.,;?"""'11!~-.-----~GENT DATE:
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I om exempt from Contractor's License Law for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License L.1w does not apply to an owner of property who builds or Improves thereon, and who does such work
himseH or through his own employees, provided that such improvementsare not Intended or offered for sale. ff, however, the building or improvement is sold within
one year of completion, the owner-builder wlll have the burden of proving that he did not build or Improve for the purpose of sale).
□ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
□ I am exempt under Section _______ Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I [have/ have not) signed an application for a build Ing permit for the proposed work.
3.1 have contracted with the following person (firm) to provide the proposed construction (Include name address/ phone/ contractors' license number):
4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name/ address/ phone/
contractors' license number):
S. I will provide some of the work~ have contr~d (hl•~r11 A-follnwln11: Persons to P(OVide t,lie work Indicated (Include name/ address/ phone/ type of work):
OWNER SIGNATURE: i.-< ••• -· _□AGENT DATE: 'f-lJ-15 ·v -
CONSTRUCTION LENDING AGENCY, IFANY:
I hereby affirm that there Is a construction lending agency for the performance of the work this permit Is issued (Sec. 3097 Ill Civil Code).
Lender's N.ime: \~Jl"ol\Q. Lender's Address: ___________________ _
~W'
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 2SS05, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No
Is the facility to be constructed within 1,000feet of the outer boundal)' of a school site? □ Yes □ No
IF ANV OF TI-IE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCV MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVIO:S AND lHE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building constructlo n.
1 hereby authorize representative of the Qty of Carlsbad to enter upon the above mertioned property for inspection p11poses.1 Al.SO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE OlY OF CARLSBAD AGAINST ALL UABIUTIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY tN CONSEQUENCE OF
THE GRANTING OF TI-11S PERMIT.OSHA: An OSHA permit is nequired for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
1635 Faraday Ave Carlsbad, CA 92008
B-1
Ph: 760-602-2719 Fax: 760-602-8558
Page 2 of2
····~ .. -----
Email: Building@carlsbadca.gov
Rev. 06/18
I I ,,-~~,~ 1 1 f ' ' I ' " '
, . , -P&RMl1"'1NSPECTION 1-tlSIORY REPORT (CBR2019--2618)
f ' 1'\ ' ( >
Pnrmit Type: BLDG-Residential Application Date: 09/19/2019 Owner: TRUST TRUESDALE BRENDA L
Work Class: Alteration Issue Date: 09/27/2019 Subdivision: CARLSBAD TCT#72-33
Status: Closed -Finaled Expiration Date:
lVR Number:
03/31/2020
21901
Address: 2510 Navarra Dr, 516
Carlsbad, CA 92009-7026 .. _..., ____ .. ___ ---·----·•··•·· ... ·•···•··-···-'· _ .. ., ... ,_.""·•······--· .. ·•··-··-···---···-···-"··-··-·····-··------·---------_-___ -..:...:::----=========---
Scheduled Actual . Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
09/30/2019 09130/2019 BLDG-47 105719-2019
Fireplace/Chimney
Checklist Item
BLDG-Building Deficiency
10/03/2019 10/03/2019 BLDG-47 106299-2019
Fireplace/Chimney
10117/2019 10/17/2019 BLDG-Final
Inspection
Checklist Item
BLDG-Building Deficiency
107795-2019
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
cancelled Chris Renfro
COMMENTS
Passed Chris Renfro
COMMENTS
Rough frame, duct flue for chimney. Ok to
drywall
Passed Chris Renfro
COMME.NTS
Re inspection Complete ----
Re inspection Complete
Passed
No
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
... ··--·---· ·---········--·· ······•·--·•······---··---•··•····· ... •-·-·-·-··•"·-------·----··--··-----------· -----·•·---~--·--·----·-·-
October 17, 2019 Page 1 of 1
'
Brenda Truesdale
2510 Navarra unit 516, Carlsbad, California
Inspection date
May 06, 2019
Reason for inspection
Inspection report requested
Level of inspection
Level I and parts of Level II
Prepared by
Cole Richards I C.S.I.A. Certified Inspector #9940 I F.I.R.E. Certified Inspector I
760-436-0086
The Village Chimney Sweep Inc.
_a_
THE VILLAGE
tHlliMEY swm•
' •
Inspection Address: 2510 Navarra unit 516 Inspection Date: May 06, 2019
Disclaimers and notifications
Please note: This report is the exclusive property of The Village Chimney Sweep Inc. and Brenda Truesdale.If this
report is for the required Level ll inspection for the sale or transfer of property it is mandatory that full notification of
defects be made to the current owner and the potential buyer.
Recommendations: Any recommendations are made as a service to our customers and is not a contract or
proposal for work for repairs even if an approximate cost is given. ff requested a separate repair estimate may be
submitted.
Grandfathering: When chimney repair is found to be necessary due to potentially hazardous or unsafe conditions,
there is no grand fathering tor any portion of the chimney. There is no state or national code that "Grandfather's"
any portion of a chimney that represents a potential hazard.
Professional chimney inspection: This report is the result of a professional chimney inspection. The report reflects
the level of chimney inspection as stated in the report. Everything in this report is factual and supported by the
standards represented in the International Residential Building Code 2006, NFPA 211 2016, U.L. and
manufacturer installation instructions. The observations in this report are factual and fully supported by
documentation, codes and standards.
Inspection level indicated: National Fire Protection Agency (NFPA 211) has 3 levels of inspection. We have
added a basic level for estimating purposes. The basic estimating level is restricted to the areas required for a
specific estimate request such as an exterior chimney repair. This level does not assess the usability, safety or
functionality of the entire structure. This level is a courtesy for the convenience of the client to provide an estimate
for the repairs desired. The NFPA 211 level or combination of levels used will be indicated on the report.
Visual observation: All aspects of this report are taken from visual observations. Visual observations whether an
internal camera system is used or not are limited in scope by the angle of perspective. Hidden flaws could exist
that are not available for a visual observation from the angle of the perspective available.
Inaccessible areas: There are areas of the chimney, fireplace or appliance that are not available for inspection.
These areas include but are not limited to: attic space, hearth support, hearth extension, basement, crawl space,
areas concealed between floors and walls and areas that the person inspecting may not have been given access
to at the time of the inspection. Roof construction or weather conditions may limit or prohibit roof access. The
Customer understands that the Inspector cannot obtain access to certain portions of the fireplace and certain
enclosed adjacent areas. The Inspector makes no representations express or implied and will not be responsible
in any way whatsoever tor deficiencies, improper installation, or improper equipment in inaccessible areas. The
findings listed within this report are based on the condition of the appliance system at the time of this inspection
and may be limited due to access or type of inspection requested
Inspection validity timeframe: We cannot control what happens to this chimney, fireplace, vent, or appliance after
we leave the location. Customers may move or construct things that change the clearance to combustibles.
Weather, use, misuse, lack of use, vegetation, age and alterations are just some of the factors that can change
the condition of the structure. We will not be held responsible for any of these changes that may affect the
suitability for use of this chimney, vent or appliance.
Suitable for intended use: The purpose of the inspection is to determine reasonable suitability to use this
chimney, appliance, vent, or fireplace as the structure was intended when constructed or inspected. A fireplace is
intended to be used as an ornamental structure that is designed for short term use and not as a source of heat.
Use of a fireplace or other appliance in a way that it is not intended to be used could present a hazard.
Measurements: Some of the measurements in this report are approximations. Some of the approximations are
used to aid the estimator to write a proposal for work. These approximations are also valuable to help determine
proper equipment needed to insure the safety of the chimney professionals doing any of the proposed work. Any
inaccuracies in any of these approximations does not invandate the findings in this report.
""·
( .,.
L.;opyngm I ne v11Iage L.;nimney :;weep Inc.
Generated with Chimspect Software
Page 2
Inspection Address: 2510 Navarra unit 516
Inspection Date: May 06, 2019
Chase #1
Factory-built chimney #1
• Flue blocked or significantly restricted or obstructed by design or construction flaws:
Meets industry standards
• Factory-built chimney assembled with appropriate parts: Meets industry ~tandards
• General condition: Meets industry standards
• U.L. listed factory-built chimney: Yes
• Chimney joint security and stability: Does not meet industry standards
Slight disconnection at offset 8 feet from flue opening. Recommend having flue reconnected before use.
• Installation, support and condition of offsets in the flue: Does not meet industry
standards
• Proper sizing and suitability for the appliance installed: Meets industry standards
• Level of cleanliness of the venting system: Meets industry standards
• Chimney Type: Air insulated
Fireplace #1
• Configuration (Please indicate the combustible clearances if applicable): Open wood
burning
• Manufacture, brand, model: Majestic L36
• Are readily accessible parts of factory-built fireplace and chimney free of rust and
corrosion?: Meets industry standards
• Are the mechanical draft systems and damper operable and free of rust and
corrosion?: Meets industry standards
• Owner's manual present and available at the time of inspection?: Yes
· Condition of the firebox : Meets industry standards
• Condition of the smoke chamber and connection to the flue: Meets industry standards
• General condition of the factory-built fireplace: Meets industry standards
Inspection Address: 2510 Navarra unit 516
inspection Date: May 06, 2019
Copyright The Village Chimney Sweep Inc.
Generated with Chimspect Software
Page3
· Do the clearances around the factory built fireplace meet the manufacturers
recommendations including the hearth extension?:
Paper should be removed before fireplace is used.
Gap should be sealed to prevent heated gases from rising into combustible framed areas.
· Condition of the hearth extension: Meets industry standards
· Condition of the fireplace facing: Meets industry standards
· Are the factory-built fireplace glass doors and accessories (inserted items)
approved?: Meets industry standards
Inspection Address: 251 0 Navarra unit 516
Inspection Date: May 06, 2019
Copyright The Village Chimney Sweep Inc.
Generated with Chirnspect Software
Page4
Findings and conclusions
Reconnecting the pipe and removing combustible material from the above the face of the firebox is to be done
before the chimney could be considered in usable condition.
Copyright The Village Chimney Sweep Inc.
Generated with Chimspect Software
Page 5
l Fi~eplaces ~
l~Plusl
1833 Diamond Street, Suite 101
San Marcos, CA 92078
760. 752. 7789 Phone
760.752.7781 Fax
www.flreplacesplus.com Contractors License INl11295
Item#
RH-36
Date: September 4, 2019
To: BRENDA TRUESDALE
2S10 NAVARRA ST, UNIT S16
CARLSBAD, CA 92009
Job: TRUESDALE
2510 NAVARRA ST, UNIT S16
CARLSBAD, CA 92009
Home Phone: (760) 445-961S
Cell Phone: (760) 814-7121
Email: bltelvise@yahoo.com
Bid by: ELI CENDEJAS
Scope of Work: Homeowner or contractor to remove the tile on face existing fireplace, open up the wall about 62" from base of the
fireplace so we can pull old fireplace out and adjust framing for new Heat-N-Glo RH-36 wood burning fireplace.
Fireplaces Plus to demo existing fireplace, flue pipe and install Heat-N-Glo RH-36 wood burning fireplace on two story
run and off-set with 30 degree off-set on chase install. Pipe mix subject to change at job check or install. Note: HOA is
responsible for chase cowr & termination caps. We will also need HOA approl/OI to be on roof and we are not
responsible if any tHes are damaged in process of un-instaN & re-install of tile fireplaces.
Qty Description Unit Price Price
l Royal Hearth 36 Wood Fireplace 36" woodburning radiant w/ 789.00 789.00
tra ditiona I brick
DM1036
AK24
FLEX
1 Original bi-fold glass doors with black trim
1 Outside air kit (1 each)
l 4" x 10' Flex Duct
409.00 409.00
13.00 13.00
25.00 25.00
.·· ..................... -. ............ -Total for.flue Pll!.e. and c.aP ........... ------........... ________ _ 1~:!·1 ISL348
!sL336
.SL318
!SL312
!sL306
!SL330
'FS338
5 4 ft. (1220mm) pipe section
1 36" (915mm) pipe section
1 18" (455mm) pipe section
2 12" (305mm) pipe section
2 6" chimney section
1 30 Degree elbow (offset and return I
2 Firestop for straight up flue
Total Materials
10% Discount
Labor -Demo Fireplace, Flue Pipe & Disposal
Labor
7.75% Tax on materials
Total proposal
This proposal is valid 30 days from the date listed above.
141.00
119.00
80.00
72.00
60.00
183.00
40.00
If you have any questions regarding the above proposal, please feel free to give us a call.
Thank J10U for your interest In our busifleSSII
OWNER: FIREPlACES PLUS: ___ _
80.00
144.00
120.00
183.00
80.00
2,667.00
(266.70)
275.00
625.00
186.02
$ 3,"86.32
1 of 1
NW Installation Manual·i\ _· ···,r·, -•.
Installation and Fireplace Setup SEP 2 ;
20)§
INSTALLER: Leave this manual with party responsible for use and 'operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
HEAT&GLO ..
No one builds a better fire
Model(s):
RH36
RH42
WOODBURNING FIREPLACE
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recomends HHT
Factory Trained or NFI certified professionals.
~~~~ lil~l~~i~-
F<fi.{,f.
A WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• DO NOT overtire. Overfiring will void your
warranty.
• Comply with all minimum clearances to com-
bustibles as specified. Failure to comply may
cause house fire.
A WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• Keep clothing, furniture. draperies and other flammable
materials away.
A WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfire and generate
poisonous gases (i.e. carbon monoxide).
Heat & Gia• RH36/RH42 • 4044-194 lnsIDltluO:elli)'l-2 c, Ii
~{,1Key:
1
2
3
4
5
►
DANGER! Indicates a hazardous situation which, if not avoided ~ result in death or serious injury.
WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
CAUTION/ Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Indicates practices which may cause damage to the fireplace or to property.
Table of Contents
Product Specific & Important Safety Information 6 Shrouds
A. Fireplace Certification 4 A. Radiation Shield
B. Non-Combustible Materials 4 B. Field Constructed Shrouds
C. Combustible Materials 4 1. Open Top Shroud
Getting Started 2. Mailbox Style Shroud
A. Typical Fireplace System 5 3. Roofed Style Shroud
B. Design and Installation Considerations 6 7 Finishing
1. Selecting Fireplace Locations 6 A. Finishing Material
2. Locating Fireplace & Chimney 7 B. Hearth Extension, Building and Finishing
C. Tools and Supplies Needed 8 1. Hearth Extension 4" or more below
D. Inspect Fireplace and Components 8 Fireplace Opening
E. Fireplace System Requirements 8 2. Raised Hearth Extension Less Than 4" Below
Framing and Clearances Fireplace Opening
A. Fireplace Dimensions 9 3. Fireplace Opening and Hearth Extension Flush
B. Clearances 10 with Floor
Minimum Clearances to Combustibles 10 C. Non-Combustible Sealant Material
C. Construct the Chase 11 D. Mantel and Wall Projections
D. Frame the Fireplace 12 E. Sidewalls/Surrounds
E. Secure and Level the Fireplace 12 8 Fireplace Setup
F. Protective Metal Hearth Strips 13 A. Gas Log/Lighter Provision
G. Outside Air Kit (optional) 14 B. Wood Burning Inserts
Chimney and Termination Requirements 9 Reference Materials
A. Chimney Requirements 15 A. Chimney Components
B. Offsets/Returns 16 B. Optional Components
C. Termination Requirements 17
Chimney Installation
A. Typical Chimney System 18
B. Assemble Chimney Sections 19
C. Install Chimney Air Kit 19
D. Secure Offset/Return 20
E. Install Ceiling Firestops 20
F. Install Attic Insulation Shield 21
G. Roof Penetration 22
H. Install Chase/Chase Top 22
I. Termination Cap Requirements 23
J. Install Termination Cap 23
~ "
\ ..
""c:· ' •
r;. _ Heat & Gia • Rrj36/RH42 • 4-9. 44-194 Installation Manual • Rev O • 09/18
'J ~ , ,. • I ~ f'!:._ ' .. i . l
-~• : 1 :..,, . fi-',
----------·---·-
25
25
25
26
26
27
28
29
29
30
30
31
32
33
33
34
38
> 1--0
' '
Specifications RH-36
HEAT&GLO.
Please consult the manufacturer's
installation manual for all details an d
requirements before making a final
design layout decision.
Royal Hearth 36
No one builds a better fire Wood-burning Fireplace
MODEL
RH-36
FRONT WIDTH
Actual Framing Actual Framing Actual Framing Actual Framing
41 42 23-3/4 42 39-1/2 39-3/4 21-3/8 21-1/2
. .._ '
SEP 2 5 2019
23-3/4" [603] -1 7-3/8"
11-7/8" ~[187] 302 -
---Etlf---ll--tllit----
21 -3 / 8"
, 'ID [5431
--C 'J ----=-~---'~~.=.....l
Outside
Air
\
Gas Q
Knockout \
21"
(533)
18-3/4"
[476)
9-1/4"
.. [235)
i---7-112" --l-
[191 J
I 41" (1041) ---1
Top View
......-'---->---L-'---=-=--=~---'--'--.L......>~ _L
36" [914)
Front View
7-1/2"
[191)
21"
[533]
7-1/2"
[191)
-l 14-1/8"
[359)
T~
39-1 /2"
[1003)
H
■, <Doro1I
Gas
Knockout \
7-1/2"
(191)
36 X 18-3/4
I
9-1/4"
(235)
I I
Left Side View Right Side View
Additional information an be found onhne at www.heatnglo.com or www.f,replaces.com
<> '-'p Q Sper1f1cat1ons RH-36
APPLIANCE LOCATION
In an exterior chasr or projecting into a garage
12"[305) minlmumfmm nreplace opening to perpendicular wall
Along a wall i
I-50" 11 2101--l-=1 f-42" 110671-H
MANTEL PROJECTIONS
Combustible Wal
Standoff
Non-combustible Decorative Facing
such as:
Steel, Iron, brick,
tile, concrele, state,
glass, plasters.
Combustible
Decorative Facing
12" 1305] -----j
---r 6" 1152) minimum
I
I
12'. jJ05J mtmmum
1:i~f~~ base of fireplace toce•in9
Measured from top of fireplace opening
MANTEL LEG/WALL PROJECTIONS
12"
[305]
HEARTH EXTENSIONS
·• [102] l'flll'IIAlCJffl 001we,enbol'\oln01
fir•~~ opining and wrftioe
o!heartheueotJor,
12"
1305]
FRAMING DIMENSIONS
•39.3/4"
[1010]
Header MUST NOT
be notched!
Extra space needed for
outside air connection.
a•~See install manual for
42" __.., [203] other details. ---..,.1c-=-~ [1067]
• If interior of chase is drywalled, add thickness to
• Adjust header height for raised floor under fireplace
CLEARANCE TO COMBUSTIBLES
u Q)
:g~ ~ 48' I 1219)
<.)
HEARTH EXTENSION CONSTRUCTION
Continuous, non-Fireplace
combustible sealant Opening
1/2" Micore Hearth Tile stone or other •~
Extension (or no~~ombustible material equivalent insulation) /I '--------r4· [102]
See Install Manual ./ l l minimum "-► ::: ... ' •. :. '·.·.;'. I F l I=
2" [51] of the Protective Floor constructed of wood or Metal Hearth Strip is required
other combustible material under the front of the fireplace
PRODUCT LISTING CODES Product information provided is not
complete and is subJect to change
without notice. Product installation
must adhere strictly to 1nstruct1ons
accompanying product to avoid risk
of fir and potential iniury.
us UL 127
CAN ULC-S610
Add1t1onal information can be found online al www.heatnglo.com
HEAT&GLO. A bi.and of Hearth & Home Technolo91es-... J:,c.
c@ususno No one builds a batt9r fire Lakeville. MN Phone: (800) 927-6841
Web: www.heatnglo.com
W":J, HrK,/RH-36_tJ511
Majestic Thulman fireplaces have t he
following guarantees, approvals,
recommendations or listings:
62·26R
INTERNATIONAL CONfERENCE OF BUILDING OFFICIALS
REPORT NO. 1581.
(Buildi,g Officials
Cor.ference of ~meiica, rnc.)
No. 7011
(Southern BuildlnR Code C~ngre.sl
Look for the U.L. Label on the Fireplace
Listed under one or more of the following
U. S. Patents: 2634720, 2856837;
and 2821975.
I" CLEARANCE TO
COMBUSTIBLES FOR L42A
2• CLEARANCE TO
C0r,1BUSTIBL£S FOR L36A
0UTSI 0£ Pl PE DIA.
Model L28A-OPEN FRONT
0\c{
INSTALLATION
INSTRUCTIONS
Models L36A and L42A -OPEN FRONT
Models L36AR and L42AR -OPEN RIGHT END
Mod·els L36Al and L42AL -OPEN LEFT END
READ INSTRUCTIONS CAREFULLY;
REFER TO YOUR MODEL NUMBER
LOCAL CODES:
Local Building Codes should be consulted in all cases as to the particu-
lar requirements concerning the installation of factory-built fireplaces.
Majestic Thulman Fireplaces are intended for use in accordance with
Standard NFPA #211 of the National Fire Protectron Association.
CLEARANCES:
Any of these models may be placed directly on a combustible floor, against
a combustible wall or raised on a wooden platfonn without clearance from combustible construction. Framing members l'l'.ay be placed directly against
the side and back of the fireplace. Combustible floors must be protected at front and sides of openings, as shown below. Combustible walls, at right
angles and within 40"of fireplace open ing, must be protected as shown·below,.
L28A, L36A sections require 2" clearance, and L42A sections require 111
clearance to combustibles.
Fireplace
Seal Crack
Extended Hearth
Galvanized Iron to be used
on the floor under the crack.
CAUTION: Seal crack
between firep l ace and
extended hearth. n
9o'MAX . ,A.LL IIOOE!.S AOOITJO~AL FLUE SIJPP~T REOUIRED AT 4:1 &75' l"ROM FLOOA.
I" Cl.EARP.ta TO
COM9UST1BL£S FOR L42A
13112" FOR 1.28.11 81 L56A UNITS
16" FOR L42.A UNITS
USE NOH--COMBIJS"fl
MATERIAL ON ( StfAOl';O AR A
2" Cl.£ARANCE TO C~FORLIIA AMO l.3U I USE NON-COMBUSTMIU! MATPlilj. Of! SIIAOf0 AAEAS PROTECT ADJACENT
COMBUSTIBlE SIDE
WAU WITHIN 4-0"
Of F.P. OPENING
WITH MAJESTIC
SP◄O INSULATED
WALL PANEL
I·
See Framing Instructions
on Paga 5.
Model L28A
~
J..---3a•--..; i--24'--l
FRONT SIDE
J T 52"
kl 36' :_ L ';f-53 . 7''
46" · I 1-124•~
FRONT SIOE/;&
T
'-----42"--...i __ j ~6"
6'
!====-=-==-=5=3•==-==--==-=:...=_= _= -..;::r_r_
~-t.· 1
l--2411;'--4
1)1 gc: FRONT
CORNER tNSTALLATION . 'IL L .(t,,
Models L36AR
& L36AL (shown)
T
52"
l
SIDE
24"
T
l
_J__
~r _, l /t
24"
0 _ ___,___, _J_
i-;;..--36"
41"--
FRONT
1-4+--42"
47Jt;
FRONT
3(::;-·