Loading...
HomeMy WebLinkAbout2510 WEST RANCH ST; ; CB154586; Permit(City Of Carlsbad Commercial Permit Print Date: 01/08/2019 Permit No: CB154586 Job Address: 2510 West Ranch St Permit Type: BLDG-Commercial Work Class: New Status: Closed - Finaled Parcel No: 2081951000 Lot 4: Applied: 12/28/2015 Valuation: $937,503.00 Reference U: DEV11017 Issued: 09/27/2016 Occupancy Group: Construction Type: --oi Permit Finaled: U Dwelling Units: Bathrooms: 00-7 3 Inspector: MCoIl Bedrooms: Orig. Plan Check 4: C. ) Final Plan Check U: Inspection: 1/8/2019 7:39:07AM Project Title: ROBERTSON RANCH WEST VILLAGE Description: COMMIND - COMM MONTECITO @ ROBERTSON RANCH: 6,015 SF CLUB HOUSE / 947 SF COVERED PATIOS Applicant: ALLIANCE LAND PLANNING AND ENGINEERING INC ELIZABETH SHOEMAKER 2248 Faraday Ave Carlsbad, CA 92008-7208 760-431-9896 Owner: SHAPELL MONTECITO LLC 8383 Wilshire Blvd, 700 Beverly Hills, CA 90211-2400 323-988-7590 Contractor: TB PENICK AND SONS INC 15435 Innovation Or San Diego, CA 92128-3442 858-558-1800 Total Fees: Total Payments To Date: Balance Due: Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 760-602-8560 f I www.carlsbadca.gov Permit Type: BLDG-Commercial Application Date: 12/28/2015 Owner: SHAPELL MONTECITO LLC Work Class: New Issue Date: 09/27/2016 Subdivision: Status: Closed - Finaled Expiration Date: 06/24/2019 Address: 2510 West Ranch St Carlsbad, CA IVR Number: 711449 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete BLDG-Fire Final 066964-2018 Scheduled Dominic Fieri Incomplete Checklist Item COMMENTS Passed FIRE- Building Final No January 08, 2019 Page 7 of 7 Permit Type: BLDG-Commercial Application Date: 12/28/2015 Owner: SHAPELL MONTECITO LLC Work Class: New issue Date: 09/27/2016 Subdivision: Status: Closed - Finaled Expiration Date: 06/24/2019 Address: 2510 West Ranch St Carlsbad, CA IVR Number: 711449 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiendy Prelim final walk No BLDG-Building Deficiency Ok to move in furniture only No 05102/2018 05/02/2018 BLDG-Final 056772-2018 Partial Pass Michael Collins Reinspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency TCO pending Planning/Landscape approval Yes BLDG-Building Deficiency Ok to move in furniture only No BLDG-Building Deficiency Prelim final walk No 05/29/2018 05/29/2018 BLDG-55 059338-2018 Cancelled Michael Collins Reinspection Complete Fence/Preplaster Checklist Item COMMENTS Passed BLDG-Building Deficiency Wrong permit called in. No 12/11/2018 12/11/2018 BLDG-Final 078423-2018 Partial Pass Michael Collins Reinspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency TCO pending Planning/Landscape approval Yes BLDG-Building Deficiency Ok to move in furniture only No BLDG-Building Deficiency Prelim final walk No BLDG-Building Deficiency Partial Yes 12/24/2018 12/24/2018 BLDG-Final 079797-2018 Cancelled Paul Burnette Reinspection Complete Inspection Checklist Item COMMENTS . Passed BLDG-Building Deficiency TCO pending Planning/Landscape approval Yes BLDG-Building Deficiency Prelim final walk No BLDG-Building Deficiency Ok to move in furniture only No BLDG-Building Deficiency Partial Yes 12/26/2018 12/26/2018 BLDG-Final 079859-2018 Failed Michael Collins Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency TCO pending Planning/Landscape approval Yes BLDG-Building Deficiency Ok to move in furniture only No BLDG-Building Deficiency Partial Yes BLDG-Building Deficiency Prelim final walk No 01/08/2019 01/08/2019 BLDG-Final 080521-2019 Passed Paul Burnette Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency TCO pending Planning/Landscape approval Yes BLDG-Building Deficiency Partial Yes BLDG-Building Deficiency Ok to move in furniture only No BLDG-Building Deficiency Prelim final walk No January 08, 2019 Page 6 of I MIG R_ E"H=16 Permit Type: BLDG-Commercial Application Date: 12/28/2015 Owner: SHAPELL MONTECITO LLC Work Class: New Issue Date: 09/27/2016 Subdivision: Status: Closed - Finaled Expiration Date: 06/24/2019 Address: 2510 West Ranch St Carlsbad, CA IVR Number: 711449 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Exercise room Only Yes 12/06/2017 12/06/2017 BLDG-17 Interior 042773-2017 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Office and Break room only Yes 12/11/2017 12/11/2017 BLDG-17 Interior 043023-2017 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Lounge area hard lid & walls Yes 12/14/2017 12/14/2017 BLDG-17 Interior 043611.2017 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Clubhouse/server closet Yes BLDG-18 Exterior 043423-2017 Cancelled Michael Collins Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Wrong code - No 12/19/2017 12/19/2017 BLDG-17 Interior 043738-2017 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Reception & tower only Yes 02/14/2018 02/14/2018 BLDG-33 Service 048786-2018 Passed Michael Collins Complete Change/Upgrade Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDG.E Yes 02/16/2018 02/16/2018 BLDG-23 049118-2018 Failed Michael Collins Reinspection Complete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 03/23/2018 03/23/2018 BLDG-Final 052615-2018 Partial Pass Michael Collins Reinspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Ok to move in furniture only No 04/10/2018 04/11/2018 BLDG-Final 054484-2018 Partial Pass Michael Collins Reinspection Incomplete Inspection January 08, 2019 Page 5of7 Permit Type: BLDG-Commercial Application Date: 12128/2015 Owner: SHAPELL MONTECITO LLC Work Class: New Issue Date: 09/27/2016 Subdivision: Status: Closed - Finaled Expiration Date: 06/24/2019 Address: 2510 West Ranch St Carlsbad, CA lVR Number: 711449 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, complete lath No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 11/17/2017 11117/2017 BLDG-18 Exterior 040774-2017 Passed Michael Collins Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-84 Rough 040775-2017 Passed Michael Collins Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency See card for pick up notes Yes BLDG-44 Yes Rough-Ducts-Dampers BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-Building Deficiency Not ready, complete lath No 11/21/2017 11/21/2017 BLDG-16 Insulation 041183-2017 Partial Pass Michael Collins Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Walls at exterior/interior restrooms, office, Yes conference & administrative rooms. 11/27/2017 11/27/2017 BLDG-16 Insulation 041431-2017 Passed Michael Collins Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Walls/hard lid at Exercise, Club house, Yes Lounge & Tower BLDG-Building Deficiency . Walls at exterior/interior restrooms, office, Yes conference & administrative rooms. BLDG-17 Interior 041430-2017 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency At Clubhouse restrooms & conference room Yes BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Wrong code No 12/04/2017 12/04/2017 BLDG-17 Interior 042161-2017 Passed Michael Collins Complete Lath/Drywall January 08, 2019 Page 4of7 MEAPER ¶6L! Permit Type: BLDG-Commercial Application Date: 12/28/2015 Owner: SHAPELL MONTECITO LLC Work Class: New Issue Date: 09/27/2016 Subdivision: Status: Closed - Finaled Expiration Date: 06/24/2019 Address: 2510 West Ranch St Carlsbad, CA lVRNumber: 711449 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 08/28/2017 08/28/2017 BLDG-13 Shear 032931-2017 Passed Michael Collins Panels/HD (ok to wrap) Checklist Item COMMENTS BLDG-Building Deficiency Per deputy insp. report and city spot check 09/15/2017 09/15/2017 BLDG-13 Shear 034802-2017 Failed Michael Collins Panels/HO (ok to wrap) Checklist Item COMMENTS BLDG-Building Deficiency 09/26/2017 09/26/2017 BLDG-17 Interior 035834-2017 Cancelled Michael Collins Lath/Drywall Checklist Item COMMENTS Complete Passed Yes Reinspection Complete Passed No Reinspection Complete Passed Complete Complete BLDG-Building Deficiency Wrong code No BLDG-Building Deficiency Not ready No 09/29/2017 09/29/2017 BLDG-13 Shear 036416-2017 Passed Michael Collins Panels/HO (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Minor pick up Yes 10/04/2017 10/04/2017 BLDG-15 036794-2017 Passed Michael Collins Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency BLDG-Building Deficiency 10/17/2017 10/17/2017 BLDG-84 Rough 037664-2017 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 11/02/2017 11/02/2017 BLDG-84 Rough 039411-2017 Combo(14,24,34,44) Truss walk, see card for pick up nailing only except at Breezeway, Conference & Longe areas Failed Michael Collins COMMENTS Not ready, complete lath Failed Michael Collins Yes No Reinspection Complete Passed No No No No No Reinspection Complete January 08, 2019 Page 3of7 Permit Type: BLDG-Commercial Application Date: 12/28/2015 Owner: SHAPELL MONTECITO LLC Work Class: New Issue Date: 09/27/2016 Subdivision: Status: Closed - Finaled Expiration Date: 06/24/2019 Address: 2510 West Ranch St Carlsbad, CA IVR Number: 711449 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 06/06/2017 06/06/2017 BLDG-IS 025428.2017 Partial Pass Michael Collins Reinspection incomplete RooflReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency nailing only except at Breezeway, No Conference & Longe areas 06/07/2017 06/07/2017 BLDG-15 025594-2017 Passed Michael Collins Complete Roof/ReRoof (Patio) Checklist Item . COMMENTS Passed BLDG-Building Deficiency Sheathing nailing & upper drag straps only Yes BLDG-Building Deficiency Not ready, missing blocking and straps No BLDG-Building Deficiency No 07/03/2017 07/03/2017 BLDG-21 027739.2017 Partial Pass Jonathan West Reinspection Incomplete Underground/Underf ioor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Vent pipe leaking. No 07/05/2017 07/05/2017 BLDG-24 027861.2017 Cancelled Jonathan West Reinspection Complete Rough/Topout Checklist Item COMMENTS Passed BLDG-Building Deficiency No 07/11/2017 07/11/2017 BLDG-24 028330-2017 Passed Michael Collins Complete Rough/Topout Checklist Item COMMENTS Passed BLDG-Building Deficiency Lower level top out only. Yes 07/17/2017 07/17/2017 BLDG-I3 Shear 028980-2017 Failed Michael Collins Reinspection Complete Panels/HD (ok to wrap) Checklist Item COMMENTS . Passed BLDG-Building Deficiency No BLDG-17 Interior 028979-2017 . Failed Michael Collins Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 08/24/2017 . 08/24/2017 BLDG-I3 Shear 032674-2017 Failed Michael Collins Reinspection Complete Panels/HD (ok to wrap) Checklist Item COMMENTS . Passed BLDG-Building Deficiency No January 08, 2019 Page 2 of 7 £111111 TiTIi TTh,T Permit Type: BLDG-Commercial Application Date: 12/28/2015 Owner: SHAPELL MONTECITO LLC Work Class: New Issue Date: 09/27/2016 Subdivision: Status: Closed - Finaled Expiration Date: 06/24/2019 Address: 2510 West Ranch St Carlsbad, CA IVR Number: 711449 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 11/10/2016 11/10/2016 BLDG-21 000693-2016 Partial Pass Paul Burnette Reinspection Incomplete UndergroundlUnderf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-22 000694.2016 Partial Pass Paul Burnette Reinspection Incomplete Sewer/Water Service Checklist Item COMMENTS Passed BLDG-Building Deficiency ' . Yes 11/30/2016 11/30/2016 BLDG-I1 003519-2016 Passed Paul Burnette Complete Foundation/Ftg/Pier s(Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/27/2017 01/27/2017 BLDG-21 011586-2017 Passed Andy Krogh Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Bldg 16 pool room, to feed injector pump Yes station, not yet installed. No sewer connection BLDG-22 011587-2017 Passed Andy Krogh Complete Sewer/Water Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Bldg 16 pool room, to feed injector pump Yes station, not yet installed. No sewer connection 01/30/2017 01/30/2017 BLDG-11 011788.2017 Passed Michael Collins Complete Foundation/Ftg/Pier S (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Lower restroom only. Yes 06/02/2017 06/02/2017 BLDG-15 025099.2017 Failed Andy Krogh , Reinspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, missing blocking and straps No 06/05/2017 06/05/2017 BLDG-15 025247.2017 Failed Michael Collins Reinspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, missing blocking and straps No January 08, 2019 Pagel o17 RECORD COPN CB 154586 2510 WEST RANCH ST • MONTECITO @ ROBERTSON RANCH' CARLSBAD INSPECTION RECORD;6,015 SF PATIOS Building Division COMMIND COMM El INSPECTION RECORD CARD WITH APPROVED Lot#. ALLIANCE LAND PLANNING & ENGINEERING PLANS MUST BE KEPT ON THE JOB El CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION FOR BUILDING INSPECTION CALL 760-602-2725 OR GO TO: www.Carlsbadca.pov/Buildinp AND CLICK ON Request Inspection" DATE: (21- 7 —7 -11 " * IF YES' IF YOU HAVE IS CHECKED BELOW THAT DIVISIONS APPROVAL IS REQUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION. ALL REQUIRED ANY QUESTIONS PLEASE APPROVALS ARE SIGNED CALL THE APPLICABLE OFF— FAX TO 760-602-8560, DIVISIONS AT THE EMAIL PHONE NUMBERS TO BLDGINSPECTIONS@CARLSBADCA.GOV PROVIDED BELOW. AFTER OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE.. CARLSBAD. CA 92008. BUILDING INSPECTORS CAN BE REACHED AT 760•602-2700 BETWEEN 7:30 AM - 8:00 AM THE DAY OF YOUR INSPECTION. Required Prior to Requesting Building Final It Checked YES Planning/Landscape 760-944-8463 Allow 48 hours ~mm- iiiiiiiiiiiiiiiijliiiillill-Ifl-:7'i ME Fire PreventJon 760-602-"60 Allow LII hours - Type OF Inspection Type of Inspection z Mello #11 FOUNDATION Date Inspector _________ Date #31 IJ ELECTRIC UNDERGROUND 0 UFER Inspector - #12 REINFORCEDSTEEL I LAY #34 R0UH ELECTRIC #66 MASONRY PRE GROUT #33,ØhEC1RIC SERVICE 0 TEMPORARY b.2.( t4/i g 0 GROUT OWALLDRAINS #35 PHOTOVOLTAIC #10 TILT PANELS #39 FINAL #11 POURSTRIPS #41 UNDERGROUNDDUCTS &PIPING #11 COLUMN FOOTINGS #14 SUBFRAME 0 FLOOR 0 CEILING #44 0 DUCT& PLENUM 0 REF. PIPING #15 ROOF$HEATHING(5 c&(c7/fl VI- #43 HEAT•AIRCOND.SYSTEMS #13 EXT. SHEAR PANELS oj'z4'fl #49 FINAL #16 INSULATION 11 kz-7tr (4 #81 UNDERGROUND (11,12,21,31) #18 EXTERIOR LATH it77fl'7 #t #17 INTERIOR LATH & DRYWALL -z.f13f1 #82 DRYWALL,EXI LATH, CASTES (17,18,23) #51 POOL EXCA/STEEL/BOND/FENCE ______ #83 ROOF SHEArING, EXT SHEAR (13,15) #55 PREPLASTER/FINAL _________ ____________ #84 FRAME ROUGH COMBO (14,244,44) IL /t-7/r) #19 FINAL ______ #85 T-Bar(14,24,34,44) #22 0 SEWER & BL/CO 0 PL/CO Date Ins pector _____ #89 FINAL OCCUPANCY (19,29,39,49) Date Inspector i;i #21 UNDERGROUND OWASTE 0 WIN #24 TOP OUT C3 WASTE DWTR A/S UNDERGROUND VISUAL #27 TTJB&SHOWERPAN • A/S UNDERGROUND HYDRO •...-' ' - #23 ZASTEST 0 GAS PIPING Z/2.1j I S ____________ A/S UNDERGROUND FLUSH _____________ #25 WATER HEATER A/S OVERHEAD VISUAL #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC 1O,-34 #29 FINAL A/S FINAL A'f #600 PRE-CONSTRUCTION MEETING F/A ROUGH-IN '(/?'7 ,2IqI4#/ F/A FINAL MY bll(lo #603 FOLLOW UP INSPECTION FIXED EXTINGIJISHING SYSTEM ROUGH-IN #605 NOITCETO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST / / #610 VERBALWARNING MEDICALGASFINAL REV 102012 . SEE BACK FOR SPECIAL NOTES CB154586 2510 WE$TPACHST CARLSBAD INSPECTION RECORD 5SFC E/947FCcERED.PATIOS Building Division COMM NE COMM El INSPECTION RECORD CARD WITH APPROVED LOW ALLIANCE LAND PLANNING & ENGINEER) 'iG PLANS MUST BE KEPT ON THE JOB 0 CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION nI rkr Dfl co v El FOR BUILDING INSPECTION CALL: 760.602-2725 -. OR GO TO: www.Carlsbadcagov/Buildina AND CLICK ON "Request inspection" V. - DATE: NO I YES Required Prior to Requesting Building Fln4 If Checked YES - Date Inspector Notes - Planning/Landscape 760-944-8463 Allow 48 hours s• 4 ___________________ CM&I (Engineering Inspections) 750-438-3891 Call before 2 P z - t/ Fire Prevention 760-602-4660 Allow 48 hours j2 flI rv i • I TvDe of Jnsection Type 61 Inspection Date #11 FOUNDATION Inspector r.i.i.11DL'I Date Inspector #31 0 ELECTRIC UNDERGROUND 0 UFER #12 REINFO RCED STEEL #34 ROUME(ECTRIC #66 MASONRYPREGROUT #33 ØELECTRICSEVICE OTEMPORARY frl. 0 GROUT 0 WALL DRAINS #35 PHOTOVOLTAIC #10 TILT PANELS #39 FINAL - #11 POURSIRIPS r.i&II:r_ [s. - 441 UNDERGROUND DUCTS & PIPING #11 COLUMN FOOTINGS #14 SURFRAME OFLOOR DCEILING #44 ODUCT&PLEI*)M QREF.PIPING #15 ROOF SHEATHING tM c/C7/,7 fr1- #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS #49 FINAL 016 INSULATION It. JZ?j'( #81 UNDERGROUND (11,12,21,31) #18 EXTERIOR LATH it71-71i7 N #17 INTERIOR LATH & DRYWALL 482 DRYWALL, ExrIATH CASTES (17,18,23) #51 POOL EXCA/ STEEL/ BOND/ FENCE #83 ROOF$HEATING1 Err SHEAR (13,15) #55 PREPLASTER/FINAL #84 FRAME ROUGH OM8O(14,24,34,44) tL/r? r, M. #19 FINAL #85 T-sar(14.24,3444: 111Mi-rJRI 1:1 I[i. #22 0 SEWER & BL/CO 0 PL/CO Date Jnspectr #89 FINAL OCCUPANCY (19,29,39,49) Date Inspector I1 #21 UNDERGROUND OWASTE_0 WTR #24 TOPOUT OWASTE DWTR A/SUNDERGROUND'YISUAL Ile #27 TUB& SHOWER PAN A/S UNDERGROUND 4Y( RO #23...ASTEST OGASPIPING ____ A/S UNDERGROUND LUSH #25 WATER HEATER A/S OVERHEAD VISUAL #28 SOLAR WATER A/S OVERHEAD HYDPOSTAT(C #29 FINAL A/S FINAL V ce F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UPINSPECTION FIXED E)MNGUISHINSiSTEMROUGH-IN #605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #601 WRITTEN WARNING FIXED EXTINGUISHING 'STEM FINAL V /1 #609 NOTICE OFVIOLATION MEDICAL GAS PRESSURETEST #610 VERBALWARNING MEDICALGASFINAL I- REV 10)2012 V • SEE;SACKFDR SPECIAL NOTES 10 A NOW\ Services Daily Report Tuesday, Jan 23, 2018 Montecito @ Robertson's Ranch Robertson's Ranch West Village Carlsbad, Ca Job#:1016519 WEATHER Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 06:07 AM 44°F 61% SW 0MPH 4MPH 0 I Clear 10:13AM 73°F 10% SW 4MPH 11 MPH 0 I Clear 02:05 PM 70°F 21% SW 11MPH 11 MPH 0 I Clear TIME ARRIVAL 10:53 AM Dave Hanselman On site as requested at 6:30 REFERENCED DOCUMENTS 10:54 AM Dave Hanselman (Location Sheet LC-8, LC-10) (Details Sheet L-5D2) Powered By NoteVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Tuesday, Jan 23,2018 1 Page 1 of 7 PERMIT NUMBERS 10:55 AM Dave Hanselman City of Carlsbad REINFORCING STEEL 11:01 AM Dave Hanselman Verfied rebar placement size grade laps and ties for (6) Pilaster, (2) Gate Colms (first lift), (2) Gate Walls, (1) Monument wall with Colm's, and BBQ at Club House, located around Entrance Circle, by building 11 and Bio Retention Basin, PA-8. Rebar in place per structural details (Sheet L-SD2) r I . - / - ----' - -;-zr - - -,-:-- 1 -47 --- - --.4 , u -iA•' I ,. . ..,-.- -. '-i- Powered By NoteVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Tuesday, Jan 23,2018 1 Page 2 of 7 : I. '.--- / 2' Powered ByNbt sVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Tuesday, Jan 23, 2018 1 Page 3 of 7 '-- -,._._,I r ' 'al I a%4 - - -,--,-'.• / - - • • - $1: ,_/ •,'c. . 11:05 AM Dave Hanselman Observed placement of 10 yd Robertsons Mix RS 300P42, 3000 psi, 3/8 grout in Col m's, Gate Colms/ Walls, and BBQ at stated locations. Grout placed with pump and consolidated-reconsolidated by mechanical vibrator. /1 PoweradBy NoteVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Tuesday, Jan 23, 2018 1 Page 4 or i Powered By NoteVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Tuesday, Jan 23,2018 1 Page 5 of 7 TESTS PERFORMED ON-SITE 11:09 AM Dave Hanselman 1 set of 4 (3x3'x6') grou: samples were taken from 10 yds Robertsons Mix RS 300P42, 3000 psi grout. Slump at 9.5, Concrete temp at 64, Air temp at 50. COMPLIANCE 11:15 AM Dave HanseI.an Rebar, ties placement in 6) Colms. First lift on (2) Gateway Colms and Walls, (1) Monument wall with Colms, and BBQ, located around Entrance Circle, by bui1d3ng 11 and Bio Retention Basin, PA-8, in place per structural drawings. The 10 yds Robertsons Mix RS 300P42, 3000 psi, grout placed in Colm's, Walls, and BBQ was done per approved specifications. Powered By NoteVault Nova Services, Inc. lMontecitO @ Robertson's Ranch I Tuesday, Jan 23, 2018 1 Page 6 of 7 11:16 AM Dave Hanselman Off site at 10:00 Employee Signature: Powered By NoteVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Tuesday, Jan 23,2018 1 Page 7 of 7 Lt N OVA Daily Report Friday, Sep 01, 2017 Robertson's Ranch, Montecito RobertsonVs Ranch West Village Carlsbad ,Ca Job#:1016519 WEATHER Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 06:14 AM 71°F 99% SW 0MPH 0MPH 0 I Clear 10:09 AM 84°F 71% SW 5MPH 7MPH 0 I Clear 02:01 PM 83°F 74% SW 6MPH 9MPH 0 I Clear GENERAL NOTES 06:57 AM Jeff Burgess Arrived at Job Site 7:00 am Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Friday, Sep 01, 2017 1 Page 1 of 3 / REFERENCED DOCUMENTS 03:12 PM Jeff Burgess Reference Documents: Detail 6/SO.2 PERMIT NUMBERS 03:15 PM Jeff Burgess Permit # CB2016-0021 REINFORCING STEEL 03:21 PM Jeff Burgess On Site As Requested By Client To Observe the Placement of Reinforcing Steel For Ramp Wall Ftgs ,Stair WaF Ftgs AnJ Pilasters At and Around Pool Area at Clubhouse. This Work is Ongoing And Continues. Verified All Reinforcing Steel For Size, rade, L 1p, and Clearances Per Stamped Approved Drawings. TESTS PERFORMED ON-SITE 03:21 PM Jeff Burgess No Testing Preformed Today. COMPLIANCE 03:22 PM Jeff Burgess The Work Inspected WAS in Compliance with the Approved Contract Documents. TIME DEPARTED 03:23 PM Jeff Burgess Departed Project At 9:00 am Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Frida, Sep 01, 2017 1 Page 2 of 3 Employee Signature: Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Friday, Sep 01, 2017 1 Page 3 of 3 Daily Report Tuesday, Sep 05, 2017 Robertson's Ranch, Montecito Robertson\'s Ranch West Village Carlsbad Ca Job#: 1016519 WEATHER Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 06:02 AM 69°F 99% SW 3MPH 3MPH 0 I Partly Cloudy 10:04 AM 75°F 91% SW 8MPH 8MPH 0 I Mostly Cloudy 02:05 PM 78°F 86% SW 7MPH 12 MPH 0 I Partly Cloudy TIME ARRIVAL 02:12 PM Dave Hanselman On site as requested at 6:50 REFERENCED DOCUMENTS 02:16 PM Dave Hanselman (480-3U) (650,2) (3/SD2) (RFl-030) .1 T I I 1 ii UZ :1: H I ..' I PERMIT NUMBERS 02:18 PM Dave Hanselman City of Carlsbad # CBC 2016-0021 REINFORCING STEEL 02:28 PM Dave Hanselman Verified rebar placement for Pool Area retaining walls! Entrance Colm footings located in Phase PA-8. Wall footing rebar in place per details (650.2). Colm. footing steel in place per details (3/SD2). Rebar clearances/ removal of loose debris/trash in progress (to be rechecked before concrete placement), and was assured by Able Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Tuesday, Sep 0,20171 Page 1 of 3 - -. •i .\ - --- ---- (Masonry West) problem will be corrected. Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Tuesday, Sep 05,2017 1 Page 2 of 3 COMPLIANCE 02:34 PM Dave Hanselman Reba for Phase PA8, Pool Area retaining wall and Colm footings in place per approved specifications. 02:35 PM Dave Hanselman Time departed 9:5C Employee Signature: Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Tuesday, Sep 05,2017 I Page 3 of 3 A NOVA S:vcc Daily Report Friday, Oct 20, 2017 Robertson's Ranch, Portola Robertson's Ranch West Village Carlsbad, California Job#: 1016518 WEATHER Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 06:00 AM 68°F 80% SW 4MPH 9MPH 0 I Mostly Cloudy 10:04 AM 68°F 79% E 4MPH 6MPH 0 I Mostly Cloudy 12:56 PM Dave Hanselman On site as requested by 8:00 REFERENCED DOCUMENTS 12:58 PM Dave Hanselman (Site plan, seepic.) (Details 15/SD6) ., - ,.1 • V ' V - -- :JIthIIJI51E1 12:59 PM Dave Hanselman City of Carlsbad # CBC 2016-0021 Powered ByNoteVault Nova Services, Inc. I Robertson's Ranch, Portola I Friday, Oct 20,2017 1 Page 1of 3 1'• REINFORCING STEEL 01:09 PM Dave Hanselman Performed Inspection for rebar placement, size, grade, laps, footing width/ depth on 8' CMU Patio Free Standing Walls, located in Phase PA-8, BLDG #1(5) walls located on West side of building 1, and (2) walls are located on the North side. Rebar! Footing size in place per structural details (15! SD6) (#4 32' oc. vert with (2) #4 cont. Hor in footing) (Mason's used #4 16" oc. with (3) #4 cont. Hor.). Footings to be cleaned free of loose debris and trash and assured by Mike (Masonry Contr.) that it will be corrected TV 1V I 1 - • V . £•• - , : \j4fI?7'? f.( • . 4, V - V ' • -V• f V • / t-. V • 1 Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Portola I Friday, Oct 20,2017! Page 2 of 3 TESTS PERFORMED ON-SITE 01:13 PM Dave 1-lanselman N/A COMPLIANCE 01:16 PM Dave Hanselman All rebar/ footing size for 8" Patio Free Standing Walls in Phase PA-8, BLDG #1. With (5) walls located on the West side and (2) walls on the North side a in place per structural details I1Id1iL!fl1 01:17 PM Dave -lanselman Off site at 10:00 Dave Hanselman Powered By NoteVz,ult Nova Services, Inc. I Robertson's Ranch, Portola I Friday, Oct 20,2017 1 Page 3 of 3 NCI\1A Daily Report Robertson's Ranch, Montecito Robertson's Ranch West Village Carlsbad, Ca Job#: 1016519 WEATHER Monday, Oct 23, 2017 Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 06:07 AM 61°F 46% SW 2MPH 4MPH 0 I Clear 10:01 AM 84°F 14% SW 1MPH 4MPH 0 I Clear 02:01 PM 86°F 23% SW 4MPH 9MPH 0 I Clear TIME ARRIVAL 09:04 AM Emad Beshay On site as requested at 6:30 AM PERMIT NUMBERS 09:06 AM Emad Beshay CBC2016-0021 REINFORCING STEEL 09:09 PM Emad Beshay CMU retaining wall footing at pool area of Montecito Robertson Ranch. Observed #5@16" on center each way as per detail 3/L-SD2 and (3) longitudinal #4 bars at top and bottom with #4 transverse @ 18" on center with #4 CMU wall vertical dowels @ 16" on center as per detail 1 sheet 26 Civil drawl ng# 480-3 E project# MS 14-07. Powered By Note Vault Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Oct 23, 2017 1 Page 1 of 3 - - - ry-- I - .. ,.-...- j.- • 154 , -' CONCRETE/SHOICRETE 09:09 PM Emad Beshay Observed concrete placement at patio CMU wall footing at senior BLDG and retaining CIVIL) wall footing at pool area at montecito BLDG. Observed Robertson's concrete mix placed using trailer pump and consolidated manually. cast one set of sample 5(4X8) cylinders from 2nd truck ticket# 3228585, truck# 1590. required strength 2500PS1 at senior BLDG footing and 3000PSI at montecito BLDG footing. 30 CY placed Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Oct 23, 2017 1 Page 2 of 3 COMPLIANCE 09:05 AM Em3d Beshay Work observed comply with approved plan to the best of my knowledge ICC# 8008238 09:08 PM Ernd Beshay departure at 10:30 AM Emad Beshay: Powered By Not VauIt Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Oct 23, 2017 1 Page 3 of 3 Project Name: Project No.: Date: Report No.: °\o"cr ciq'\\ kifrj 1 OA Location: Author: Day: (circle one) I W I F S S Clienf-) Superintendent: Contractor: Foreman: Soil Engineer: Geologist: Weather: (circle one) 'P• Wcg Overcast Rainy Other: Unit/Phase/Lots: 'J Plan File No. Permit No. 1j bp Observation Summary: Initials:J1 A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at Date: the site are substantially in conformance with those assumed in the geotechnical report. Initials: A representative of LGC Valley, Inc. observed the footing excavation(s). The footing Date ) excavation(s) extend into the proper bearing strata and are in general conformance with the I / recommendations of the geotechnical report. Initials: A representative of LGC Valley, Inc. measured the footing setback from the slope face. The Date: 1 (3DJt1 setback was in general accordance with the recommendations of the geotechnical report. Initials:__ p93Q,çVA 1flc4 ciion J\cII r oy- _______ Notes: Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing the concrete. Based on the expansion potential of the underlying soils, presoaking of soil below slabs may be recommended. Consult the geotechnical report for the presoaking recommendations. We note that clayey soils may take an extended period of time and the contractor should schedule accordingly. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e, heavy rain, a construction/placement delay, etc.), we should be contacted to perform additional site observations, as necessary. Lihe and grade of the tooting excavation(s) are not part of the purview of LGC Valley, Inc. Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil expansion index test results are contained in the As-Graded Geotechnical Report provided at the completion of grading. LGC Valley, Inc. Date Technician Hours FOOTING-OBSERVATION Received by: LGCVALLEY, INC. SUMMARY Geotechnical Consulting Print: White - File Copy Yellow - Client Copy Pink - Field Copy Gold - Client/Agency Copy ri iA NOVA ,ervks DAILY REPORT Robertson's Ranch, Montecito RobertsonVs Ranch West Village Carlsbad, Ca Job#: 1016519 Monday, Jan 30, 2017 WEATHER Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 07:05 AM 57°F 36% SSW 4MPH 6 MPH 0 IN Clear 12:00 PM 69°F 51% SSW 11MPH 12 MPH 0 I Clear TIME ARRIVAL 06:59 AM Robert VanderPol, II 0700 REFERENCED DOCUMENTS 09:36 AM Robert VanderPol, II Approved PT plans. PT shop drawings. PERMIT NUMBERS 09:36 AM Robert VanderPol, II CB-161993 (#11) CB-154586 [Rec#16] Iø4S. 250 WMAMMSt =. IN$PEcfl ttCORD f94 Moflte$1th411: Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Jan 30,2017 1 Page 1 of 4 PRESTRESSED CONCRETE 07:15 AM Robert VanderPol, II Counted tendons in building 11. Tendon count matches PT shop drawing for type 1 building. Outline and tendon count matches type 1 building but reversed (i.e. mirror image). 02:54 PM Robert VanderPol, II Completed inspection of rebar installation for building #11. Checked size, grade, spacing, laps, shapes, bar counts, tendon counts, tendon profiles and hold down sizes & embedments per plans. All noted problems corrected. Clearances and cleanliness to be checked at time of casting. Cruz[Etivista], and Pete [TBP] were informed. Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Jan 30,20171 Page 2 of 4 02:55 PM Robert VanderPol, II Inspected reinforcing installation in the shower rooms, which is the east finger of the north wing of the recreation building. Checked size, grades, spacing, laps, bar counts, tendon counts, tendon profiles, hold down sizes & embedments per plans and PT shops. All noted problems corrected. Clearances and cleanliness to be checked at time of casting. Etivista and TBP were informed. 02:56 PM Robert VanderPol, II Began preparing stressing paperwork for building #11. TESTS PERFORMED ON-SITE 02:56 PM Robert VanderPol, II No tests. Powered BoteVault y N Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Jan 30,20171 Page 3 of 4 COMPLIANCE 02:56 PM Robert VanderPol, II Performance of today's inspections complied with approved documents. Reinforcing installation in building 11 complies. Reinforcing installation in east finger of north wing, recreation building complies. TIME DEPARTED 03:23 PM Robert VanderPol, II 1530 144t Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Jan 30, 2017 1 Page 4 of 4 Daily Report Friday, Aug 11, 2017 Robertson's Ranch, Montecito RobertsonVs Ranch West Village Carlsbad, Ca Job#: 1016519 Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 07:01 AM 68°F 99% SW 4MPH 5MPH Overcast 10:01 AM 72°F 94% SW 6MPH 9MPH Mostly Cloudy 02:01 PM 75°F 86% SW 9MPH 11 MPH Clear GENERAL NOTES 07:45 AM Michael McMahon I arrived at the job site as requested at 700am for a pre grout inspection of the masonry to the pool equipment enclosure adjacent to building 16. The work is at first lift height and has been performed to the details on RSD 5. The #4 reinforcement bars were placed in keeping with the details, 24 on center for horizontal and vertical bars. This is in accordance with detail lion RSD 5. Laps were at 30 minimum per the detail. The work was performed to the plan on RS2.1 by Masonry West Please see pictures below for permit data and status of work Powered By NJoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Friday, Aug 11, 2017 1 Page 1of 4 • I :•.,jI1 , . _________•:, 08:00 AM Michael McMahon Powered By NoteVault Nova Services, Inc. I Robertszr s Ranch, Montecito I Friday, Au == 11, 2017 1 Page 2 of 4 t llf A r - * Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Friday, Aug 11, 20171 Page 3 of 4 TT. :- JrH - - PLAN-ON (I ( Employee Signature: - U / Powered By NoteVault Nova Services, Inc. I Roberssn's Ranch, Montecit I Friday, Ag :1,2017 1 Page 4 of 4 éA ì NOVA Svices Daily Report Wednesday, Aug 16, 2017 Robertson's Ranch, Montecito RobertsonVs Ranch West Village Carlsbad, Ca Job# 1016519 Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 06:05 AM 66°F 78% SW 4MPH 6MPH 0 I Overcast 10:01 AM 74°F 60% SW 0MPH 1MPH 0 I Partly Cloudy 02:10 PM 77°F 62% N 3MPH 5MPH 0 I Clear GENERAL NOTES 07:53 AM Michael McMahon I arrived at the job site as requested at 7.00am for a pre grout inspection of the masonry to the pool equipment enclosure adjacent to building 16. The work is in the process of being completed to the second lift height by Masonry West personnel. The installation of the reinforcement was in keeping with details on sheet, all at 24° on center for vertical and horizontal. Bars are #4 throughout with the exception of the opening which were #5 with a 12" lap. All other laps were 30" minimum per the details. By the end of this Site visit the work is now set for a pour. 07:59 AM Michael McMahon 261' t-r 41 Powered By NoteVault . Nova Services, Inc. I Robertson's Ranch, Montecito I Wednesday, Aug 16, 2017 1 Page 1of 4 08:20 AM Michael McMahon -;L TT 1. --------:" - - -•- -• Powered By NoteVaut Nova Services, Inc. I Robertson's Ranch, Montecito I Wednesday, Aug 16, 2017 1 Page 2 of 4 08:28 AM Michael McMahon delete 0 F11 a a L JE a ui 1 Ii POWered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Wednesday, Aug 16, 2017 1 Page 3 ot 4 Ct jOJ Employee Signature: U -J Powered By NoteVault Nova Services, tnc.I Robertson's Ranch, Montecito I Wednesday, Aug 16,20171 Page 4 of 4 r 'LI N OVA S rVS Daily Report Wednesday, Sep 13, 2017 Robertson's Ranch, Montecito RobertsonVs Ranch West Village Carlsbad, Ca Job#: 1016519 Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 06:03 AM 69°F 99% SW 3MPH 4MPH 0 I Overcast 10:08 AM 71°F 89% SW 9MPH 11 MPH 0 I Overcast 02:03 PM 75°F 72% SW 9MPH 11 MPH 0 I Clear GENERAL NOTES 03:57 PM Jeff Burgess No Testing Preformed Today TIME ARRIVAL 09:30 AM Jeff Burgess Arrived at Job Site 9:00 am F' Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Wednesday, Sep 13, 2017 1 Page 1of 4 '-F Powered By NoteVIt Nova Services, Inc. I Robertson's Ranch, Motecito I Wsdnesda, Sep 13, 2017 1 Page 2 014 REFERENCED DCiCL MENTS 03:50 PM Jeff Burgess Reference Docurrent Details 6/SO.2, RSD5 Detail 11, 13. ORCO Wall Syst#-=rn V ew Wall PERMIT NUMBERS 03:50 PM Jeff B1rg€!s Permit #s GR16030 CBC 2016-0021 MASONRY 03:56 PM Jeff Brgss On Site As RequestEt By Client To Observe the Placement of Reinforcing Steel For Perimeter Site Wall At PA7 From Lot 20-23. This it T.O.W39" With Pilasters. (5) Ftgs @ Frees:andng Pilasters Between Lot 19 and 20 PAS- 2 Pool Area Walls drectly In Front of the Leasing Office. 1st Lift 39-54" Verified CMU ay-L p and all Reinforcing Steel For Size, Grade, and Clearances Per Stamped Approved Drawings. Powered By Note?aul Nova Services, Inc. I Robertson's Ranch, Montecito I Wednesday, Sep 13, 2017 1 Page 3 of 4 COMPLIANCE 038 PM Jeff Burgess The Work Inspected WAS in Compliance with the Approved Contract Documents t*,1pI,J 03:59 PM Jeff Burgess Departed Project At 10:00 am Employee Signature: Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Wednesday, Sep 13, 2017 1 Page 4 of 4 NQYA vtLS Daily Report Thursday, Sep 28, 2017 Robertson's Ranch, Portola Robertson's Ranch West Village Carlsbad, California Job#: 1016518 WEATHER Time Temp Hum W-Dir W-Speed W-Gust Precip Condition 06:01 AM 60°F 99% SW 0MPH 0MPH 01N Partly Cloudy 10:16AM 70°F 71% SW 5MPH 8MPH 0 I Clear 02:04 PM 74°F 82% SW 6MPH 11 MPH 0 I Clear GENERAL NOTES 07:14 AM Jeff Burgess Arrived at Job Site 7:00 am REFERENCED DOCUMENTS 07:45 PM Jeff Burgess Reference Documents:Approved Concrete Mix Design # RS250P41 2500 PSI Powered By NoteVault -- Nova Services, Inc. I Robertson's Ranch, Portola I Thursday, Sep 28,2017 1 Page 1 of 2 07:46 PM Jeff Burgess Permit # GR160003 CONCRETE/SHOTCRETE 07:50 PM Jeff Burgess On Site As Requested By Client To Observe the Placement and Consolidation of 10+ Cubic Yards concrete for Monument Sign Footings. 1 Ftg At The Intersection of of Robertson St/ West Ranch And 2 Ftgs At Portola Entrance. TESTS PERFORMED ON-SITE 07:53 PM Jeff Burgess Testing Preformed Today: 1 set of 5 Test Cylinders Cast COMPLIANCE 07:53 PM Jeff Burgess The Work Inspected WAS in Compliance with the Approved Contract Documents. Jeff Burgess: Powered By NoteVault Nova Services Inc. I Robertson's Ranch, Portola I Thursday, Sep 28. 2017 1 Page 2 of 2 N C) \ Daily Report Montecito @ Robertson's Ranch Robertson's Ranch West Village Carlsbad, Ca Job#: 1016519 WEATHER Time Temp Hum W-Dir W-Speed W-Gust 06:01 AM 64°F 84% SW 0MPH 0MPH 10:01 AM 68°F 72% SW 4MPH 7MPH 02:01 PM 70°F 65% SW 11MPH 11MPH TIME ARRIVAL 03:52 PM Dave Hanselman On site as requested at 6:30 REFERENCED DOCUMENTS 03:53 PM Dave Hanselman (Location, Civil Plans Sheet 2) Wednesday, Nov 01, 2017 Precip Condition 0 IN Overcast 0 I Overcast 0 I Overcast n _L.14 a' - ------- I __]- ¼ _154 i N. - - — 2 I' ' •1 ' L i - 03:55 PM Dave Hanselman City of Carlsbad # CBC 2016-0021 Powered By NoteVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Wednesday, Nov 01, 2017 1 Page 1 of 4 M 04:00 PM Dave Hanselman On site to observe placement and sampling, of part, of 18 yds Robertscns Mix RS 200G42, 2000 psi, 3/8 grout in 8" CMU Sign! Entrance Walls located in Phase PA-8, on south end of building 1 and 4. Concrete placed with pump and consolidated-reconsolidated by mechanical vibrator. L Powered By Note Vault Nova Services, Inc. I Montecito @ Robertson's Ranch I Wednesday, Nov 01,20171 Page 2 of 4 'I Powered By NoteVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Wednesday, Nov 01, 2017 1 Page 3 of 4 TESTS PERFORMED ON-SITE 04:03 PM Dave Hanselman 1 set of 4 (3x3x6) grout samples were taken from Robertsons Mix RS200G42, 2000 psi, 3/8 grout. Slump at 10, Concrete temp at 72, Air temp at 61. 04:08 PM Dave Hanselman Part of the 18 yds Robertsons Mix RS 200G42, 2000 psi, 3/8 grout placed in Sign! Entrance Walls located in Phase PA-8, on the south end of building land 4 was poured per approved specifications. 04:09 PM Dave Hanselman Off site at 9:00 Dave Hanselman: Powered By NoteVault Nova Services, Inc. I Montecito @ Robertson's Ranch I Wednesday, Nov 01,20171 Page 4 of 4 / C8154586 2510 WEST RANCH ST ( MONTECITO @ ROBERTSON RANCH: 6,015 SF CLUB HOUSE /947 SF COVERED PATIOS \ COMMIND COMM Lot#: ALLIANCE LAND PLANNING & ENGINEERING 2- 22- To Pt PCoD73 E!nl Inspection required by: IZ7L4D P1 C\ L3 Plan UCM&I @ Sw CC UEL / I 44- CuD flLC @ bo OJ1 P\j JX3 ? y 10 PLANNING ENGINEERING tFIREExpedite LES Required? Y N HazMar APCD Health Forms/Fees Sent Encina Fire HazHeaIthAPCD P E & M School (._ sewer f Stormwater Special Inspection CFD LandUse: Density: ImpAl PFF:(Y) N Comnnts Date Building Planning Engineering Fire Need? / EDi Final Inspection required by: Plan J CM&I J Fire SW 5C)4-qg 1UED Approved Date By BUILDING 1 -)---i PLANNING I_-2-4-I5 C._W ENGINEERING - j_t - o FIRE Expedlte?(Y) DIGITAL FILES Required? V N HaaMat APCD Health Forms/Fees Sent Recd Due? By Encina V N Fire V N HazHealthAPCD V N PE&M Iaizs,'is I'2-I2--/t5 9.22. lb V N School (2 1/?-7/1t.p V N Sewer V N Stormwater V N Special Inspection V N CFD: UY N I i/QJ/ft LandUse: Density: lmpArea FY: 5/ lb Annex: Fq I Factor: 2_ PFF: () N ComnInts Date Date Date Date Building Planning Engineering Fire Need? one i Done Done 0 Done I