Loading...
HomeMy WebLinkAbout2511 STATE ST; ; CB143521; PermitCity of Carlsbad 1635·Faraday Av Carlsbad, CA 92008 03-30-2015 Residential Permit Permit No: 'cB143521 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: 2511 STATE ST CBAD RESDNTL 2030543443 $301,913.00 Sub Type: CONDO Lot#: 43 Constuctlon Type: 58 · · Reference #!J.QTf3D1i~ Structure Type~™ Status: ISSUED Applied: 12/16/2014 Entered By: JMA Bedrooms: 0 Bathrooms: 0 Plan Approved: 03/30/2015 Issued: 03/30/2015 Inspect Area: Project Title: Orig PC tPGt400.37=:J STATE ST.TOWNHOMES: PHS. 1 81 Plan Check #: 375 SF 1 ST FLR COMMERClAU/ 1,772 SF LIV/ 444 SF GAR/ 76 SF DECK/ 646 SF ROOF DECK Applicant: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341-1289 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park In Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BID #2 Fee BID #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $1,339.12. $0.00 $937.38 ($500.00) $0.00 $39.25 $6,190.00 $0.00 $0.00 $0.00 $0.00 $0.00 · $0.00 $0.00 $0.00 $0.00 $0.00 $3,931.00 FS1 ($3,931.00) $0.00 $12.00 $0.00 Total Fees: $24,066.09 Total Payments to Date: Owner. TAYLOR MORRISON OF CA, LLC 1450 100 SPECTRUM DR IRVINE CA 92618-4960 949-341-1289 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL \\., MECHANICAL "T:OTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES $24,066.09 Balance Due: FS1 $0.00 $317.00 $4,800.00 $0.00 $5,494.82 $5,072.14 $0.00 $0.00 $0.00 $0.00 $0.00 $210.00 $89.00 $65.38 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $24,066.09 $0.00 Clearance: ------ NOTICE: Please take NO ICE th approval of your project In eludes the "lmpos ltlon' of fees, dedications, reservations, or other exactions hereafter collectlvely referred to as 'fees/a s.' Yo have 90 days from the date this permit was Issued to protest Imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth In Government Code Sectlon 66020(a), and file the protest and any other required Information with the City Manager for processing In accordance with Carlsbad Municipal Code Sectlon 3.32.030. Fallure to timely follow that procedure w\11 bar any subsequent legal action to attack, review, set aside, void, or annul their Imposition. You are hereby FU RTI-IER NOTIFIED that your right to protest the specified fees/ exactions DOES NOT APPLY to water and sewer connectlon fees and capacity changes, nor planning, zonlng, grading or other similar appHcatlon processing or ser,;ce fees In connection with this project. NOR DO ES rr APPLY to BllY Inspection List Pennit#: CB143521 Type: RESDNTL CONDO Date Inspection Item ____ _ 12/14/2015 89 Final Combo 12/14/2015 89 Flnal Combo 09/21/2015 39 Flnal Electrical Q9/21/2015 39 Final Electrical 09/17/2015 39 Final Electrical 07/22/2015 17 Interior Lath/Drywall 07/17/2015 18 Exterior L.ath/Drywall 07/15/2015 18 Exterior Lath/Drywall 07/14/2015 84 Rough Combo 07/13/2015 84 Rough Com.bo , 06/30/2015 16 Insulation 06/18/2015 13 Shear Panels/HD's 06/16/2015 13 Shear Panels/HD's 06/10/2015 17 Interior Lath/Drywall 06/09/2015 15 Roof/Reroof 06/01/2015 17 Interior Lath/Drywall 05/28/2015 15 Roof/Reroof 05/27/2015 17 Interior Lath/Drywall lns~~t_C?~ __ ~ PY AP PY PY PY PY PY PY PY PY PY PY PY PY PY PY PY PY RI PA PA .. PA CA AP CA AP NR PA AP NR PA AP PA ~: 05/26/2015 16 Insulation PY PA 05/13/2015 17 Interior Lath/Drywall PY PA 05/06/2015 17: Interior Lath/Drywall PY PA 05/04/2015 14 Frame/Steel/Bolting/Weldin PY PA 04/14/2015 11 ftg/Foundation/Piers 04/13/2015 81 Underground Combo 04/06/2015 22 Sewer/Water Service 04/03/2015 21 Underground/Under Floor 'Nednesday,December16,2015 PY PY PY PB PA NR CA AP STATE ST.TOWNHOMES: PHS.1 81 375 SF 1ST FLR COMMERCIAL// 1,n2 SF Comments AM PLEASE/COF Page 1 of 1 (~\!TY OF CARLSBAD Buikflng Div islon · INSPECTION RECORD C8143521 2511 STATE ST STATE ST.TOWNHOMES: PHS. 1 B1 ~75 SF 1STFI R COMMFRCIAl./f 1.77? SF LIV/ 444 SF GAR/ 76 SF DECK/ 646 SF ROOF DECK ·@ INSPECTION RECORD CARD WITH APPROVED PlANS MUST BE KEPT ON TI-IE JOB RESDNTL CONDO Lot#. 43 TAYLOR MORRISON OF CA, LLC 0 CALL BEFORE 3;30 pm FOR NEXT WORK DAY INSPEC1'10N !ti FOR BlRLDING INSPECTION CALL: 76~02•2725 RECORD COPY Required Prior to Requesting Building Final If Checked YES PlannlnglLandscape 760-944-8463 Allow 48 hours CM&l fEngineerlng lnspcctloruj 760-43S-3891 Cafl hfflltt 2 pm Fire Prevention 760-602-4660 Allow 48 houn- Type of hupection coor-:,: ELECTRiCAL Date. Inspector #31 D B.ECTRIC UNDERGROUND O UFER #12 REINFORCED srm #34 ROUGH B.ECTRIC #66 MASONRY PRE GROUT #33 0 B.ECTRIC SERVICE O TEMPORARY DGROUT D WALL DRAINS #35 PHOTO VOLTAIC #10 TILTPAHB.S #39 FIIIAl #11 POURSTRJPS CO:>I<" MECHANICAL . . . #11 COLUMN FOOTINGS ' #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME D FLOOR D CElllnG #44 0 DUCT & PLENUM O REF. PIPING 115 ROOF SHEATHING 143 HEAT-AIR corm. SYSTEMS #13 EXT. SHEAR PANELS #18 INSULATION #18 EXTERIOR LATH UNDERGROUND (11,12,2.1,31) #17 INT£JIIOR LATH & DRYWALL #82 DRYWAU.,EXT LATH, GAS TES (17 ,18,23) #61 POOLEXCA/ BOND FENCE #83 ROOF SHEATING, EXT SHEAR (13,15) #55 PREPLASTER/ANAL 184 FRAME ROUGH COMBO (14,24,34,44} 1185 T-Bar f14,24,B4,44J #89 ·.ANAL OCCUPANCY (19,29,39,49) 0 SEWER & Bl/CO OP co #21 UNDERGROUND DWASTI D WTR #24 TOP OUT D WASTE D WTR A S UWDERGROUNDVISUAL #27 TUB & SHOWER PAN A/S UNDERQROUND HYDRO 123.::A:_GAS TEST D OAS'PIPINQ 'l A/S UNDERGROUND R.USH #25 WATER HEATER A/S OVERHEAD VISUAL #28 SOLAR WATER S OVERHEAD HYDROSTATIC #29 ANAL SRNAL F/AROUGH-IN #800 PRE-CONSTRUCTION MEETING F/ARNAL #803 FOLLOW UP INSPECTION FIXED EXTl~GUISHING SYSTEM ROUGH-IN #1!05 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST 1607 WRITTEN WARNINQ RIED EXTlHGUISHINO SYSTEM ANAL 1609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL OAS ANAL fiFF BACK FOR SPEC!AI. NOTES C(>1:lin11u::,· ln:rp<(1i1m & Materir,f.}, Jesting §0urIDVES1f~~~~~~~~~~~~4$~ !nspcction & Te~ting. Inc. July 28, 2015 Bulldtng OfftcJal City of cartsbad Department of aullding and Safety 163S: Faraday Ave Carlsbad, Callforn·1a 9200~ 441 l(1nl111L~tdal \V:.1y. La Huh\:), CA qrn;3 l ,6168 (St,219-1-t -29,;o,. {714'1 526-844 l FAX (56.!, 9<('>-0026 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name: Add~ss: Owne'r: Seagrove Townhomes state street Building # 6 Tayaor-Morrison unnt#' Address 40 2517 'State Street 41 25,15 state Street 42 25·13 State Stre~ 4~51~tr.set Permit CB143524 CB143523 CB143522 CB'143521 Un~t# Address 44 2509 state Street 45 2507 State Street 46 2505 State Street 47 2503 state Street Permit C8150800 C::8150799 CB143509 CB:143508 This is to certify that Southwest Inspection and testing, Inc. was employed to: perform special inspection on the above mentl'oned project at the above address, which required continuous Inspection per section 1701 of 2013 Callfonila Building Code. Brett.Alblinger -Reinfor:ced Concrete, Post-Tensioned Concn~te1 SD #6.56 wrnram Bowerr -Reinforced Concrete, Post Tensioned Concrete, SD #541 Tom Woods-Reinforced Concrete, Post Tensioned Concrete, SD # ':177 George R. Mooers II-Reinforced Concrete, Post Tensioned Concrete, SD# 1122 Steven L. God President SLG/IRW: amc LTG-.., 2- I I. '1 ¥ • {"city of Carlsbad CIRCUIT CARD B~~·-· Development Services Bulldlng Division 1635 Faraday Avenue . 760-602-2719 . www.carlsbadca.gov THIS CARD MUST BE FI1l..BD Ol!J' AND AV AILABLB AT 111B SERVICB Hl1Ull'MENT POR. THE ROUGH INSPECTION Address: z f'll Shrv Jhti-vr-Permit Number. C6 J'l:J S'l, I 0Wner: 4, I ~ _,£~ ¥.J _:; I Phone: r t11 J J.,,. I /,do · Area In Sq. R. :i-,, 77 Contractor: ~ CJI I l..L 1 ~6 • .P.it.eAi'A"S"e I Phone: (a/9 579 G,~&) PANEL: G-1,\,~ LO. 1 ooc A.LC. "?...4(:J VOLTS 7 0 3 WIRE LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR SIZE SIZE TYPE SIZE TYPE SIZE CKT LOCATION /<---I T<:.HEi. 1 2.-Q L:i, a.v 4· fJE.J )/ /() C.l) ;;).S 2 Ale 1)1. I ~ ,t:.o 3 2. C, /2-cu I' -:2. 4. IO\/ 10 CL) .;J.'7 4 A-Jc &AT>l-5 5 "2-0 {2 cu ac; D~ k:1 I I ;J.. C{} .:z.c 6 M/N( ~ / l"Cllq., 7 :z 0 I':)_ c.v L-1 ;J-t. 10\/ I;>-, cXJ ;2.£.1 8 ·sf:li:...IT rLCJ :t 9. /5' IY cu L I I~ qJ ;l..0 10 w~#IE~ 6-A~ 11 I.>' lt/ <:,\} 3 j l;L c..v :Z.ll 12 FALi lD1.>P~ 13 Jr;; /9 CV l ~ I 7, 141 GU /5 14 ,:EDIS~ 'ii>c,l/.lt!)lt$J,J 15 IS: L'I-· Cv ( . fr, Lf: I /Y. GtJ IS, 16 ~c.Nir°E./f't. J;,J ~ vfrrA ~k 15 l-Y.· <<...1 2. L.f ,~ . I t'i' cv /5" 18 p1r(l!E./ YFn .,AS eA71f 19 /CS' {'f CV •7 l i, c:i I l'f c.-u I~ 20 'hl~';f-! <: '0/N IN«-21 ;L,0 ·12-. cu '1 5' 'I 2-' 11./. c.v ,s; 22 ~rk'll!s 23 24 25 ~ 26 27 ~ 28 29 30 31 32 33 34 35 36 37 1 38 39 .\ 40 41 42 MAIN:0 -~±i AMP BRK/FUSE !2i' MLO Computed Load 1 'I I <,,'.3 AMPS BUS: AMP SH Ca/oullltlon Worlca'le« on beck Branch circuits required: Semeenuance~~;[tk~ ,, A) Lighting Clrwta 220 -3(b), 4(d) A) Size: No. ,.;;:,... 0 B) Type: fsicu O AL ' B) Two Small Appliance Circuits 210-11(e) C) Insulation: · D) Condu Size: __ C) Laundry Circuit 220-18(b) Service ground/bond: L B) Type: ~ CU O AL D) Central Heating Equipment 422-12 A) Size: No. 3 D E) Bathroom ,' 210 • 52(d) itamp locatlon(s): Remarks: UFER 250-50(c) Water P1pe 250-104 D Ground Rod 250-52 D GF~ locations 210-8, 680-70: I certify that aH termination~ hBVfl been torqued In aCOO(dance with msnufscturer's Bathroom(s) ~Kitchen Instructions and that the work shown on this circuit card-represents the fuH axt811t of !Garage(s) OHydromassege Tub the work perform&d under th/3 pennlt. Outdoors D " D OWnor AFf rotected Gire.~ 12 -~Contractor -n-t ILL"1 &17-:.:-.P'11!..A n•,:,e,,F" . Bedroom(s) (;.v !~y I» ffl::R.E Signed ~ -,,,__ l"" ~ Date .-, I "71 /f!!, -., 0 If -. e,-l Page 1 of 2 Rev. 03/09 R...'U! ) > 2. rW4 f~ IIV"", ~ . I /-1 / ' " . ' ., ', SINGLE FAMILY DWELLING ELECTRICAL S~RVICE LOAD CALCULATION . As an alternative method, the STANDARD METHOD found In ARTICLE 220'i:,fthe·Nstiona/ E/ectrlc Coc!e. may be used 1. . .GENERAL ltGHTING LOADS Dwenlng ;;l., I I 7 sq. ft. x 3 VA= 220-3(a) 6,153/ VA ·SrrnlH appliance loads .... 220-16(a) 1500 VA x 1 circuits= 3, ooo VA · Laundry loa~-:-22Q:.16(b) 150.0 VA x / circuits = (1 S QO VA · · . ;--:::,__ . . General Ughtlng Total//, 6 3 / VA 2., ·COOKING l:QUIPMENT LOADS -Nameplate Value ·Range. . . ~ VA= · ..--VA Cooktop VA= VA ~noo ~= -~ , Cooking ,Equipment Total VA 3 •. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) . , O&er ., -. ·r-VA=·. Dryer.Total '. VA 4. FIXEQ-APPUANCE LOADS 230-30 (b) (3) Dishwasher = .01$pQSal ,:: Compactor= Water Heater = Hydromassage Bathtub• Microwave Oven= . Built-In Vacuum = == ----- 5. OPTIONAL SUBTOTAL (Add all of the above totals) 6. APPLYING DEMAND FACTORS -TABLE 220-30 ·-. Flrst 10,000 VA x 100% ~ ·. · Optional Subtotal (from line 5) { Remaining -4 ,7~1 VAx40%= V , 7. HEATING ,OR AC LOAD-TABLE ~0-30 Larger of the He~tlng or AC Load-= /1 S-~O VA 7:so VA· ____ VA ____ VA _____ VA ~ J,:c,a VA ____ VA ____ VA: Fixed Appliance Total ~ I 75()· VA I'/. 7g1 VA I 10,000 VA 1111 VA f.e I OoO VA 8. OPTIONAL LOADS TOTAL (Add totals fro_m llii_es 6 and 7) = li/tl~ VA I 9. MINIMUM s-=RVICE SIZE m Qptlonal Loads Total • 7'-1, <c 3 Ampere 240Volt (Please put total on,front of card under Computed Load) ,, . , . ~ ·,,.,,(; ,.. .·. ~-•.. l. :' .' ,,: • ~ ' • t" "; ',•