Loading...
HomeMy WebLinkAbout2511 Wellspring St; ; CBRA2017-0285; PermitPrint Date: 09/12/2018 Job Address: 2511 Wellspring St Permit {City of Carlsbad Permit No: CBRA2017-0285 Permit Type: BLDG-Associated Permit Residentia Work Class: Parcel No: 2081915300 Lot#: Single Family Detached 203 Status: Applied: Closed -Finaled 11/01/2017 01/04/2018 Valuation: $488,719.08 Reference#: Occupancy Group: Construction Type: # Dwelling Units: Bathrooms: Bedrooms: 4.00 Orig. Plan Check#: DEV2016-0039 VB Issued: Permit Fina led: Inspector: CRenf Plan Check#: 4.50 PC150042 PC2016-0067 Final Inspection: 9/12/2018 3:5952PM Project Title: THE VISTAS Description: THE VISTAS: PHASE 10 / LOT 203 / PLAN 2 / 3,051 SF LIV/ 471 SF GARAGE/ 62 SF PATIO/ 204 SF CA ROOM Applicant: Owner: TOLL BROS INC JOANN EPSTINE RANCHO COSTERA LLC -2483-INACTIVE 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 725 WT own And Country Rd, 200 ORANGE, CA 92868-4723 714-347-1300 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) COMMUNITY FACILITIES DISTRICT {CFO) FEE -RES ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFO SB1473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER BENEFIT AREA FEES -B SEWER CONNECTION FEE (General Capacity all areas) STRONG MOT!ON-RESIDENTIAL SWPPP INSPECTION FEE TIER 1 -Medium BLDG TRAFFIC IMPACT Residential Single Family w/in CFO TRAFFIC IMPACT Residential Single Family w/in CFO WATER METER FEE 1" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $32,427.74 Total Payments To Date: $29,547.74 Contractor: TOLL BROS INC 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 Balance Due: $2,880.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $2,006.95 $1,292.47 $1.723.10 $66.00 $170.00 $92.00 $182.00 $8,894.69 $20.00 $5,099.00 $1,304.00 $934.00 $63.53 $238.00 $2,800.00 $2,880.00 $352.00 $4,169.00 $141.00 /Y,.t; 1\, , . PERMIT INS~ECTlq!JilS'tORY.R~PORT ((2.B(;tA2017-0285) . Permit Type; BLDG-Associated Permit Residential Application Date: 11/01/2017 Own~r: Work Class: Single Family Detached Issue Date: 01/04/2018 Subdivision: Status: Closed -Finaled Expiration Date: 02/18/2019 Address: IVR Number: 7402 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 08/14/2018 08{14{2018 08/22/2018 08/22/2018 09(12/2018 09/1212018 September 12, 2018 Checklist Item BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLDG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs BLDG-Electric Meter 066976-2018 Release Checklist Item BLDG-Building Deficiency BLDG-Fire Final 066952-2018 BLDG-Final Inspection Checklist Item FIRE-Building Final 069796-2018 Checklist lte1n BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Passed Chris Renfro COMMENTS Passed Dominic Fierl COMMENTS Passed Chris Renfro COMMENTS RANCHO COSTERA LLC - 2483-INACTIVE 2511 Wellspring St Carlsbad, CA 92010-5604 Reinspection Complete Passed Yes Yes Yes Yes Complete Passed Yes Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes Page 2 of 2 { \ ' ' , , f'ERMIT INSPECTION HISTORY REPORT (~lRA2017:o285) ,, Permit Type: BLDG-Associated Permit Residential Application Date: 1110112017 Owner: RANCHO COSTERA LLC - 2483-INACTIVE Work Class: Single Family Detached Issue Date: 01104/2018 Subdivision: Status: Closed -Finaled Expiration Date: 0211812019 Address: 2511 Wellspring St Carlsbad, CA 92010-5604 IVR Number: 7402 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete 03/12/2018 03/09/2018 BLDG-21 051227-2018 Passed Chris Renfro Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/06/2018 04/06/2018 BLDG-11 054104-2018 Passed Chris Renfro Complete FoundationlFtglPier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-12 Steel/Bond 054105-2018 Passed Chris Renfro Complete Beam Checklist lte,n COMMENTS Passed BLDG-Building Deficiency Yes 0512512018 05/25/2018 BLDG-15 058997-2018 Passed Chris Renfro Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/12/2018 06112/2018 BLDG-13 Shear 060686-2018 Passed Chris Renfro Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/19/2018 06/19/2018 BLDG-84 Rough 061375-2018 Passed Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-T opout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 06/27/2018 06/26/2018 BLDG-82 Drywall, 062147-2018 Passed Chris Renfro Complete Exterior Lath, Gas Test, Hot Mop ·---------·------------·-----·------ September 12, 2018 Page 1 of 2 RECORD COPY ,~) ~ CITY OF CBRA2017 -0285 CARLSBAD 2511 WELLSPRING ST Building Division INSPECTION RECORD ii'! '"'ISPECTION RECORD CARD WITH APPROVED J\NS MUST BE KEPT ON THE JOB THE VISTAS: PHASE 10 I LOT 203 I PLAN 2 I 3.051 SF LIV I 471 SF GARAGE I 62 SF PATIO I 204 SF CA ROOM DEV2016-0039 @ CALL BEFORE 3:00 pm FOR NEXT WORI( DAY INSPECTION @ FOR BUILDING INSPECTION CALL: 760•602-2725 OR GO TO: J!!WWW~~.,!:Cjja!!'.!rl!mJil.l!.!.l!&Wi!!J!!j!!!!ng AND CLICI< ON "Request Inspection" 2081915300 11/9/2017 PC2016-0067 CBRA2017-0285 DATE: IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours IF MARKED "YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING Fire Prevention Planning/Landscape CM&J (Engineering Inspections) #66 MASONRY PRE GROUT •1 l) 0 GROUT O WALL DRAINS #10 TILT PANELS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME D FLOOR D CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSULATION #18 EXTERIOR LATH #23 #25 #28 SOLAR WATER BLDG-FINAL cone ~t POOLS #51 POOL EXCAV / STEEL #52 PLUMBING #53 ELEC / CONDUIT WIRING i EQUIPOTENTIAL BOND ·11 • .f. PREPLASTER / FENCE/ ALARMS #57 GUNITE BLDG-FINAL Date 760-602-4660 Allow 48 houfs 760-944-8463 Allow 48 hours 760-438-389 I Call before 2 pm #33 LEC SERVICE #320TEMPORARY #35 PHOTO VOLTAIC #38 SIGNS BLDG· FINAL cooc11 MECHANICAL #41 UNDERGROUND DUCTS & PIPING #44 0 DUCT & PLENUM O REF. PIPING #43 HEAT-AIR COND. SYSTEMS #82 DRVWALL,EXT LATH, GAS TES (17,18,23) Ins ector #83 ROOF SH EATING, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) ~ #85 T-Bar(14,24,34,44J BLDG· FINAL OCCUPANCY A/S UNDERGROUND VISUAL A S UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL Ins ector A S OVERHEAD HYDROSTATIC A/S FINAL F/A ROUGH-IN F/A FINAL FIXED EXTINGUISHING SYSTEM ROUGH-IN FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL MEDICAL GAS PRESSURETEST MEDICAL GAS FINAL COPY OF CARD REQUIRED Date Inspector Date Ins ector Date Ins ector Ins ector Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90631 (562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026 I SWIT Jo~ No. 1 Date 1 I REGISTERED INSPECTOR'S DAILY REPORT I ' ·/ / ( TYPE OF D Reinforced Concrete D Welding D DIA/Epoxy INSPECTION 0 Post Tensioned Concrete D Fireproofing D Wood Framing REQUIRED D Reinforced Masonry D Asphalt D Other Job Address . .l __ Tract No. Lot No .. - ~ ~ <-- Job Name I: -· Pe~.No. ,_. --Issued By -< .. _ Type of Structure Architect ' Material Description {type, grade, source) Engineer r '· -\ / I Contractor '° • •J. .__ ~ ·-' . .._ (, - Inspector's Name < I Subcontractor ---·-- TESTS PERFORMED SAMPLE AIR CONC WATER TIME SET# TRUCK# TICKET# LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS /' _) INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT-AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS /WELD MADE H.T. BOLTS TORQUED) CHECKED, ETC. --, :; -, \ -.. --, ' .. .> C "'- ~ . ~-,,:-'--.._ --t.. 'V\ . \ • !'.° L( ::1 (__ ,I ... -~ ' -"--j •• .,,,, .c: !:' - I l 1 <-? - I ( K --, ·' r / ~1 :., ·;:, ' L{;-<" (__ c ,..., '--· '--.., .... ~ "7 ... ' -r , __ ::.),2,_ -.. .> \ ,-;z -1'f.. .. -~(.' > -r:-~ -1 ~ ' ..... ./ ... '-T -...... --I .. <._ ....... ~--:. . ....! (,:~-11 1 ' ' .?. -'t--'r - L1..... <• -. 1..-, I v ~·-'--. ! 2 (. ., ' ' ., ' (·' . T ~ ' ' .__ •, -~ • ~ ..:;:> ,., ?. ·-? ·-"-> 7 <.. _, ... .::> . '--·-t CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE 0 PAGE OF -- TIMEIN TIME OUT SAMPLES ~I . TUFlE,.,OF--REGISTE ED-INS.PECTOR .. ~/ .. X--- Approved By ,k --~ · -·- SPECIALTY NO. AGENCY " Project Superintendent White -Office Copy • Canary-Accounting Copy • Pink -Inspector's Copy • Goldenrod -Jobsite Copy .J Location: W tf f..t.,s 12, t, Client: -----"/1? Q ,< •' fl~!;, Soil Engineer: UniVPhase/Lots: ,(., 178'· I 8Z. J/1 . l\"1J : \ i .t >.,· Initials:~ Date:~ ·~,,·, .·:lrfffials: ...-P.1 · · Date: 3}1,:-, JI 9 Initials: --rJn Date: 3}·,;f i) B Notes: ·O Project No.: 1.1(;1 ~r V.,. s" i '33oz -s-, o Superintendent: [J.I Geologist: Contractor: Footin Observation Summa : 0 I 8 Report No.: ,,,.,,, Day: (circle one) MTWTFSS Foreman: I' A representative of LGC Valley, Inc. observed the on~site soil conditions. The soil conditions at the site are substantially in conformance with those assumed in the geotechnical report. A representative ofLGC Valley, Inc. observed the footing excavation(s). The footing excavation(s) extend into the proper bearing strata and are in general conformance with the recommendations of the geotechnical report, 1. Footing excavations should be cleaned of loose soil and de.bris and thoroughly moistened just prior to placing the concrete. 2. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc. 3. In the event of a site change subsequent to our observation of footing excavations and prior to concrete placement (i.e. heavy rain, a construction/placement delay, etc.), LGC should be contacted to perform a recheck of footing excavations and site observations, as necessary. Technician Hours LGC VALLEY, INC. Geotechnical Consulting . White -File Copy Yellow -Client Copy Pink -Field Copy Gold -CllenUAge_ncy Copy Michael Baker INTERNATIONAL March 30, 2018 City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 Subject: Inspector: Vistas -Lots 202, 203, 204, & 205 City of Carlsbad Tract No. CT 13-03 JN 143824 Michael Baker International has performed a field survey on March 30, 2018 to field check the building fooling forms for Lots 202-205 on Wellspring Street. The results of the field survey reveal the footing forms to be within substantial conformance, both horizontally (0.1 O'±) and vertically (0.05'±) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated February 9, 2016. Sincerely, Tim Thiele, P.E. Project Manager H:\PDATA\143824_R0BERTS0N RANCH\ADMIN\CORRESPNDNC\FORM CERTSITOLL BRO_FORM_PA6_CERT15_202-205.DOC PLANNING • DES1C3N • CONSTRUCTION 5050 Avenida Encinas, Suite 260, Car1sbad, California 92008 # 760.476.9193 # FAX 760.476.9198 Offices located throughout the Country • WWW robakerlntl.com '