HomeMy WebLinkAbout2511 Wellspring St; ; CBRA2017-0285; PermitPrint Date: 09/12/2018
Job Address: 2511 Wellspring St
Permit
{City of
Carlsbad
Permit No: CBRA2017-0285
Permit Type: BLDG-Associated Permit Residentia Work Class:
Parcel No: 2081915300 Lot#:
Single Family Detached
203
Status:
Applied:
Closed -Finaled
11/01/2017
01/04/2018 Valuation: $488,719.08 Reference#:
Occupancy Group: Construction Type:
# Dwelling Units: Bathrooms:
Bedrooms: 4.00 Orig. Plan Check#:
DEV2016-0039
VB
Issued:
Permit
Fina led:
Inspector: CRenf
Plan Check#:
4.50
PC150042
PC2016-0067
Final
Inspection: 9/12/2018 3:5952PM
Project Title: THE VISTAS
Description: THE VISTAS: PHASE 10 / LOT 203 / PLAN 2 / 3,051 SF LIV/ 471 SF GARAGE/ 62 SF PATIO/ 204 SF CA ROOM
Applicant: Owner:
TOLL BROS INC
JOANN EPSTINE
RANCHO COSTERA LLC -2483-INACTIVE
725 W Town And Country Rd, 200
ORANGE, CA 92868-4709
760-720-5485
725 WT own And Country Rd, 200
ORANGE, CA 92868-4723
714-347-1300
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
COMMUNITY FACILITIES DISTRICT {CFO) FEE -RES
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -inside CFO
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement
SEWER BENEFIT AREA FEES -B
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOT!ON-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1 -Medium BLDG
TRAFFIC IMPACT Residential Single Family w/in CFO
TRAFFIC IMPACT Residential Single Family w/in CFO
WATER METER FEE 1" Displacement
WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 5/8" Displacement
Total Fees: $32,427.74 Total Payments To Date: $29,547.74
Contractor:
TOLL BROS INC
725 W Town And Country Rd, 200
ORANGE, CA 92868-4709
760-720-5485
Balance Due: $2,880.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
$2,006.95
$1,292.47
$1.723.10
$66.00
$170.00
$92.00
$182.00
$8,894.69
$20.00
$5,099.00
$1,304.00
$934.00
$63.53
$238.00
$2,800.00
$2,880.00
$352.00
$4,169.00
$141.00
/Y,.t; 1\, ,
. PERMIT INS~ECTlq!JilS'tORY.R~PORT ((2.B(;tA2017-0285) .
Permit Type; BLDG-Associated Permit Residential Application Date: 11/01/2017 Own~r:
Work Class: Single Family Detached Issue Date: 01/04/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 02/18/2019 Address:
IVR Number: 7402
Scheduled
Date
Actual
Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
08/14/2018 08{14{2018
08/22/2018 08/22/2018
09(12/2018 09/1212018
September 12, 2018
Checklist Item
BLDG-Building Deficiency
BLDG-17 Interior Lath-Drywall
BLDG-18 Exterior Lath and
Drywall
BLDG-23 Gas-Test-Repairs
BLDG-Electric Meter 066976-2018
Release
Checklist Item
BLDG-Building Deficiency
BLDG-Fire Final 066952-2018
BLDG-Final
Inspection
Checklist Item
FIRE-Building Final
069796-2018
Checklist lte1n
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Passed Chris Renfro
COMMENTS
Passed Dominic Fierl
COMMENTS
Passed Chris Renfro
COMMENTS
RANCHO COSTERA LLC -
2483-INACTIVE
2511 Wellspring St
Carlsbad, CA 92010-5604
Reinspection Complete
Passed
Yes
Yes
Yes
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 2 of 2
{ \ ' '
, , f'ERMIT INSPECTION HISTORY REPORT (~lRA2017:o285) ,,
Permit Type: BLDG-Associated Permit Residential Application Date: 1110112017 Owner: RANCHO COSTERA LLC -
2483-INACTIVE
Work Class: Single Family Detached Issue Date: 01104/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 0211812019 Address: 2511 Wellspring St
Carlsbad, CA 92010-5604
IVR Number: 7402
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete
03/12/2018 03/09/2018 BLDG-21 051227-2018 Passed Chris Renfro Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/06/2018 04/06/2018 BLDG-11 054104-2018 Passed Chris Renfro Complete
FoundationlFtglPier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-12 Steel/Bond 054105-2018 Passed Chris Renfro Complete
Beam
Checklist lte,n COMMENTS Passed
BLDG-Building Deficiency Yes
0512512018 05/25/2018 BLDG-15 058997-2018 Passed Chris Renfro Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/12/2018 06112/2018 BLDG-13 Shear 060686-2018 Passed Chris Renfro Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/19/2018 06/19/2018 BLDG-84 Rough 061375-2018 Passed Chris Renfro Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-T opout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
06/27/2018 06/26/2018 BLDG-82 Drywall, 062147-2018 Passed Chris Renfro Complete
Exterior Lath, Gas
Test, Hot Mop
·---------·------------·-----·------
September 12, 2018 Page 1 of 2
RECORD COPY
,~)
~ CITY OF CBRA2017 -0285
CARLSBAD 2511 WELLSPRING ST
Building Division INSPECTION RECORD
ii'! '"'ISPECTION RECORD CARD WITH APPROVED
J\NS MUST BE KEPT ON THE JOB
THE VISTAS: PHASE 10 I LOT 203 I PLAN 2 I 3.051 SF LIV I
471 SF GARAGE I 62 SF PATIO I 204 SF CA ROOM
DEV2016-0039 @ CALL BEFORE 3:00 pm FOR NEXT WORI( DAY INSPECTION
@ FOR BUILDING INSPECTION CALL: 760•602-2725
OR GO TO: J!!WWW~~.,!:Cjja!!'.!rl!mJil.l!.!.l!&Wi!!J!!j!!!!ng AND CLICI< ON
"Request Inspection"
2081915300
11/9/2017 PC2016-0067
CBRA2017-0285
DATE:
IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION
STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours
IF MARKED "YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING
Fire Prevention
Planning/Landscape
CM&J (Engineering Inspections)
#66 MASONRY PRE GROUT
•1 l) 0 GROUT O WALL DRAINS
#10 TILT PANELS
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#14 SUBFRAME D FLOOR D CEILING
#15 ROOF SHEATHING
#13 EXT. SHEAR PANELS
#16 INSULATION
#18 EXTERIOR LATH
#23
#25
#28 SOLAR WATER
BLDG-FINAL
cone ~t POOLS
#51 POOL EXCAV / STEEL
#52 PLUMBING
#53 ELEC / CONDUIT WIRING
i EQUIPOTENTIAL BOND
·11 • .f. PREPLASTER / FENCE/ ALARMS
#57 GUNITE
BLDG-FINAL
Date
760-602-4660 Allow 48 houfs
760-944-8463 Allow 48 hours
760-438-389 I Call before 2 pm
#33 LEC SERVICE #320TEMPORARY
#35 PHOTO VOLTAIC
#38 SIGNS
BLDG· FINAL
cooc11 MECHANICAL
#41 UNDERGROUND DUCTS & PIPING
#44 0 DUCT & PLENUM O REF. PIPING
#43 HEAT-AIR COND. SYSTEMS
#82 DRVWALL,EXT LATH, GAS TES (17,18,23)
Ins ector #83 ROOF SH EATING, EXT SHEAR (13,15)
#84 FRAME ROUGH COMBO (14,24,34,44)
~ #85 T-Bar(14,24,34,44J
BLDG· FINAL OCCUPANCY
A/S UNDERGROUND VISUAL
A S UNDERGROUND HYDRO
A/S UNDERGROUND FLUSH
A/S OVERHEAD VISUAL
Ins ector A S OVERHEAD HYDROSTATIC
A/S FINAL
F/A ROUGH-IN
F/A FINAL
FIXED EXTINGUISHING SYSTEM ROUGH-IN
FIXED EXTING SYSTEM HYDROSTATIC TEST
FIXED EXTINGUISHING SYSTEM FINAL
MEDICAL GAS PRESSURETEST
MEDICAL GAS FINAL
COPY OF CARD
REQUIRED
Date Inspector
Date Ins ector
Date Ins ector
Ins ector
Southwest Inspection and Testing, Inc.
441 Commercial Way, La Habra, Ca 90631
(562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026 I SWIT Jo~ No.
1
Date 1
I
REGISTERED INSPECTOR'S DAILY REPORT I ' ·/ / (
TYPE OF D Reinforced Concrete D Welding D DIA/Epoxy
INSPECTION 0 Post Tensioned Concrete D Fireproofing D Wood Framing
REQUIRED D Reinforced Masonry D Asphalt D Other
Job Address . .l __ Tract No. Lot No .. -
~ ~
<--
Job Name I: -· Pe~.No. ,_. --Issued By -< .. _
Type of Structure Architect
'
Material Description {type, grade, source) Engineer r
'· -\ / I Contractor '° • •J. .__ ~ ·-' . .._ (, -
Inspector's Name < I Subcontractor ---·--
TESTS PERFORMED
SAMPLE AIR CONC WATER TIME
SET# TRUCK# TICKET# LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS
/'
_)
INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS,
REMARKS, ETC. INCLUDES INFORMATION ABOUT-AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF
TEST SAMPLES TAKEN: STRUCT. CONNECTIONS /WELD MADE H.T. BOLTS TORQUED) CHECKED, ETC.
--, :; -,
\ -.. --, ' .. .> C "'-
~ . ~-,,:-'--.._ --t.. 'V\ . \ • !'.° L( ::1 (__ ,I ... -~ ' -"--j •• .,,,, .c: !:' - I l 1 <-? -
I ( K --, ·' r
/ ~1 :., ·;:, ' L{;-<" (__ c ,..., '--· '--.., .... ~ "7 ... ' -r , __ ::.),2,_ -.. .> \ ,-;z -1'f.. .. -~(.' > -r:-~ -1 ~
' ..... ./ ... '-T -...... --I ..
<._ ....... ~--:. . ....! (,:~-11 1 ' ' .?. -'t--'r -
L1..... <• -. 1..-, I v ~·-'--. ! 2 (. .,
' ' ., '
(·' . T ~
' ' .__ •, -~ • ~ ..:;:>
,., ?. ·-? ·-"-> 7 <.. _, ... .::> . '--·-t
CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE 0 PAGE OF --
TIMEIN TIME OUT SAMPLES
~I . TUFlE,.,OF--REGISTE ED-INS.PECTOR .. ~/ .. X---
Approved By ,k --~ · -·-
SPECIALTY NO. AGENCY " Project Superintendent
White -Office Copy • Canary-Accounting Copy • Pink -Inspector's Copy • Goldenrod -Jobsite Copy
.J
Location:
W tf f..t.,s 12, t,
Client:
-----"/1? Q ,< •' fl~!;,
Soil Engineer:
UniVPhase/Lots:
,(., 178'· I 8Z.
J/1 . l\"1J : \ i .t >.,·
Initials:~
Date:~
·~,,·, .·:lrfffials: ...-P.1
· · Date: 3}1,:-, JI 9
Initials: --rJn
Date: 3}·,;f i) B
Notes:
·O
Project No.:
1.1(;1 ~r V.,. s" i '33oz -s-, o
Superintendent:
[J.I
Geologist:
Contractor:
Footin Observation Summa :
0
I 8
Report No.: ,,,.,,,
Day: (circle one)
MTWTFSS
Foreman:
I'
A representative of LGC Valley, Inc. observed the on~site soil conditions. The soil conditions at
the site are substantially in conformance with those assumed in the geotechnical report.
A representative ofLGC Valley, Inc. observed the footing excavation(s). The footing
excavation(s) extend into the proper bearing strata and are in general conformance with the
recommendations of the geotechnical report,
1. Footing excavations should be cleaned of loose soil and de.bris and thoroughly moistened just prior to placing the concrete.
2. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc.
3. In the event of a site change subsequent to our observation of footing excavations and prior to concrete placement (i.e. heavy rain, a
construction/placement delay, etc.), LGC should be contacted to perform a recheck of footing excavations and site observations,
as necessary.
Technician Hours
LGC VALLEY, INC.
Geotechnical Consulting .
White -File Copy Yellow -Client Copy Pink -Field Copy Gold -CllenUAge_ncy Copy
Michael Baker
INTERNATIONAL
March 30, 2018
City of Carlsbad
Building Department
1635 Faraday Avenue
Carlsbad, CA 92008
Subject:
Inspector:
Vistas -Lots 202, 203, 204, & 205
City of Carlsbad Tract No. CT 13-03
JN 143824
Michael Baker International has performed a field survey on March 30, 2018 to field check the
building fooling forms for Lots 202-205 on Wellspring Street. The results of the field survey reveal
the footing forms to be within substantial conformance, both horizontally (0.1 O'±) and vertically
(0.05'±) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated February 9,
2016.
Sincerely,
Tim Thiele, P.E.
Project Manager
H:\PDATA\143824_R0BERTS0N RANCH\ADMIN\CORRESPNDNC\FORM CERTSITOLL BRO_FORM_PA6_CERT15_202-205.DOC
PLANNING • DES1C3N • CONSTRUCTION
5050 Avenida Encinas, Suite 260, Car1sbad, California 92008 # 760.476.9193 # FAX 760.476.9198
Offices located throughout the Country • WWW robakerlntl.com
'