Loading...
HomeMy WebLinkAbout2518 West Ranch St; ; CB161996; Permit{city of Carlsbad Print Date: 12/26/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2518 West Ranch St BLDG~Residential 2081951000 $2,129,655.00 ROBERTSON RANCH WEST VILLAGE Residential Permit Work Class: Lot#; Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Apartments 0EV11017 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Description: RESDNTL -APT MONTECITO: 13 UNIT APT BLDG TYPE 1 / 14,924 SF APT AREA/ 2,447 SF GARAGE (BLDG #14) Applicant: ALLIANCE LAND PLANNING AND ENGINEERING INC ELIZABETH SHOEMAKER 2248 Faraday Ave Carlsbad, CA 92008-7208 760-431-9896 MANUAL BUILDING PERMIT FEE Total Fees: $910.00 Owner: SHAPELL MONTECITO LLC 8383 Wilshire Blvd, 700 Beverly Hills, CA 90211-2400 323-988-7590 Total Payments To Date: $910.00 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CB161996 Closed -Finaled 05/19/2016 10/11/2016 MCol1 12/26/2018 12:33:17PM $910.00 $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Permit Print Date: 01/08/2019 Job Address: 2518 West Ranch St Permit Type: BLDG-Migrated Work Class: BLDG-Migrated Parcel No: 2081951000 Lot#: Valuation: $0.00 Reference#: DEV11017 Occupancy Group: Construction Type: # Dwelling Units: Bathrooms: Bedrooms: Orig. Plan Check#: Plan Check#: Project Title: ROBERTSON RANCH WEST VILLAGE Description: SWPPP-MONTEC\TO APARTMENTS BUILDING #14 FEE Total Fees: Total Payments To Date: Building Division Status: Applied: Issued: Permit Fina\ed: Inspector: Final Inspection: Balance Due: {City of Carlsbad Permit No: SW160477 Closed -Finaled 09/27/2016 10/11/2016 01/04/2019 AMOUNT 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ; . PERMIT INSPECTION HISTORY REPORT (CB161996) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPELL MONTECITO LLC Work Class· Status: Scheduled Date Apartments Closed -Finaled Actual Start Date Inspection Type Issue Date: 10/11/2016 Subdivision: Expiration Date: 06/10/2019 Address: 2518 West Ranch St Carlsbad, CA IVR Number: 714665 Inspection No. Inspection Status Primary Inspector Re inspection -·-··-··------------------------------------------ 1212412018 12/24/2018 12/26/2018 12/26(2018 December 26, 2018 BLDG-Final Inspection BLOG-Fin al Inspection Checklist ltom BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 079795-2018 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLOG-Structural Final BLOG-Electrical Final 079857-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Mechanical Final BLDG-Structural Final BLOG-Structural Final BLDG-Electrical Final BLDG-Electrical Final COMMENTS As noted on card Partial Cancelled COMMENTS Passed COMMENTS 12/26/18 As noted on card Partial Passed Yes Yes Yes Yes Yes Yes Paul Burnette Reinspection Passed Yes Yes Yes Yes Yes Michael Collins Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Complete Complete Complete Page 10 of 10 PERMIT INSPECTION HISTORY REPORT (CB161996) ' ' " Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPELL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/10/2019 Address: 2518 West Ranch St Carlsbad, CA IVR Number: 714665 Scheduled Actual Inspection Type Primary Inspector Re inspection Complete Date Start Date Inspection No. Inspection Status Checklist Item COMMENTS Passed BLDG-Building Deficiency All units ok except Unit 204 Yes 06/18/2018 06/18/2018 BLDG-23 061139-2018 Passed Michael Collins Complete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Unit 204 reinspection Yes 06/1912018 06/1912018 BLDG-33 Service 061431-2018 Passed Paul Burnette Complete ChangefUpgrade Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes 09/12/2018 09/12/2018 BLDG-Final 0697 48-2018 Partial Pass Andy Krogh Reinspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency As noted on card Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes 09/17/2018 09/17/2018 BLDG-Final 070196-2018 Partial Pass Chris Renfro Reinspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency As noted on card Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes 09/2412018 09/24/2018 BLDG-Flnal 070296-2018 Partial Pass Chris Renfro Reinspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes 12/11/2018 12/1112018 BLDG-Final 078419-2018 Partial Pass Michael Collins Reinspectlon Incomplete Inspection December 26, 2018 Page 9 of 10 . PERMIT INSPECTION HISTORY REPORT (CB161996) h • Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPELL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Dato: 06/10/2019 Address: 2518 West Ranch St Carlsbad, CA IVR Number: 714665 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Yes BLDG-Building Deficiency Partial, exterior only at 2nd & 3rd floors. Yes BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No 04/17/2018 04(17/2018 BLDG-17 Interior 055237-2018 Partial Pass Michael Colllns Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Units 205, 302-305 except 1/VH closets Yes BLDG-Building Deficiency Not ready No 04/18/2018 0411812018 BLDG-17 Interior 055370-2018 Cancelled Michael Collins Refnspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 04/19/2018 04119/2018 BLDG-17 Interior 055512-2018 Partial Pass Michael Collins Relnspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Units 205, 302-305 except 1/VH closets Yes BLDG-Building Deficiency Units 102-103 except at tub areas, 202-205 Yes BLDG-Building Deficiency Not ready No 0412312018 04/2312018 BLDG-17 Interior 055764-2018 Cancelled Chris Renfro Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Units 102-103 except at tub areas, 202-205 Yes BLDG-Building Deficiency Units 205, 302-305 except WH closets Yes BLDG-Building Deficiency Not ready No 04124/2018 04/24/2018 BLDG-17 Interior 056089-2018 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Units 101-103 Yes 04/25/2018 04/25/2018 BLDG-17 lnterlor 056061-2018 Passed Michael Colllns Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Units 102-103 except at tub areas, 202-205 Yes BLOG-Building Deficiency Units 205, 302-305 except WH closets Yes BLDG-Building Deficiency Not ready No 05/31/2018 05/31/2018 BLOG-23 059797-2018 Partial Pass Michael Collins Reinspection Incomplete Gas/Test/Repair, Oecem ber 26, 2018 Page 8 of 10 ' . PERMIT INSPECTION HISTORY REPORT (GB161996) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: Work Class· Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/10/2019 Address: Scheduled Date Actual Start Date 04/10/2018 04/10/2018 04/11/2018 04/11/2018 04/13/2018 04/13/2018 December 26, 2018 IVR Number· 714665 Inspection Type Inspection No. Checklist Item BLOG-Building Deficiency BLDG-44 Rough-Ducts-Dampers BLDG-44 Rough-Ducts-Dampers BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-34 Rough Electrical BLDG-Building Deficiency BLDG-Building Deficiency BLDG-17 Interior Lath/Drywall 054486-2018 Checklist Item BLDG-Building Deficiency BLDG-18 Exterior Lath/Drywall Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-16 Insulation 054844-2018 Checklist Item BLDG-Building Deficiency BLDG-16 Insulation 055124-2018 Checklist Item BLDG-Building Deficiency BLDG-18 Exterior Lath/Drywall 054908-2018 Inspection Status Primary Inspector COMMENTS Units 102-103,203 and garages Units 101,201,301. Minor pick up Complete lath Failed COMMENTS Not ready Failed COMMENTS Not ready Not ready Mlchael Collins Michael Collins Partial, exterior only at 2nd & 3rd floors. Not ready Not ready Partial Pass Michael Collins COMMENTS Wall insulation at Units 301-305 only, see card for pickup. Passed Mlchael Collins COMMENTS Need cert for 3rd floor ceiling Passed Mlchael Colllns SHAPELL MONTECITO LLC 2518 West Ranch St Carlsbad, CA Reinspection Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Reinspection Passed No Reinspection Passed No No Yes No No Reinspection Passed Yes Passed Yes Complete Complete Complete Incomplete Complete Complete Page 7 of 10 , . PERMIT INSPECTION HISTORY REPORT (0B161996) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: Wor"' Clnss: Apartments Issue Date: 10/11/2016 Subdivision: Status· Closed -Finaled Expiration Date: 06/10/2019 Address: IVR Number: 714665 Scheduled Date Actual Start Date Inspection Type Inspection No, 04/05/2018 04/05/2018 04/09/2018 04/09/2018 December 26, 2018 BLDG-17 Interior Lath/Drywall 053961-2018 Checklist Item BLDG-Building Deficiency BLDG-18 Exterior Lath/Drywall 053960-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-84 Rough Combo(14,24,34,44) 053959-2018 Checklist Item BLDG-44 Rough-Ducts-Dampers BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-Building Deficiency BLDG-Building Deficiency BLDG-18 Exterior Lath/Drywall 054466-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-84 Rough Combo(14,24,34,44) 054332-2018 Inspection Status Primary Inspector Cancelled COMMENTS Failed COMMENTS Not ready Not ready Not ready Partial Pass COMMENTS Michael Collins Michael Collins Michael Colllns Units 102-103,203 and garages Complete lath Partial Pass Michael Colllns COMMENTS Not ready Partial, exterior only at 2nd & 3rd floors. Not ready Not ready Passed Michael Collins SHAPELL MONTECITO LLC 2518 West Ranch St Carlsbad, CA Reinspection Reinspectlon Passed No Reinspection Passed No No No Reinspection Passed Yes Yes Yes Yes Yes No Reinspection Passed No Yes No No Complete Complete Complete Incomplete Incomplete Complete Page 6 of 10 '. . :''. PERMIT INSPECTION HISTORY REPORT (CB161996) ' ' ' Permit Ty pc: BLDG-Residential Application Date; 05/19/2016 Owner: SHAPELL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status· Closed -Finaled Expiration Date 06/10/2019 Address: 2518 West Ranch St Carlsbad, CA IVR Number: 714665 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLOG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 03/30/2018 03/30/2018 BLDG-84 Rough 053320-2018 Cancelled Mlchael Colllns Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding {Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 04/02/2018 04/0212018 BLDG-84 Rough 053415-2018 Failed Michael Colllns Relnspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready, lath not completed No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 04/0312018 04/03/2018 BLDG-84 Rough 053633-2018 Failed Michael Colllns Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Complete tath No 04/04/2018 04/0412018 BLDG-84 Rough 053824-2018 Partial Pass Michael Collins Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Units 202,204-205,302-305 Yes BLDG-Building Deficiency Not ready, lath not completed No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers December 26, 2018 Page 5 of 10 . . . PERMIT INSPECTION HISTORY REPORT (CB161996) Porrnit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPELL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date; 06/10/2019 Address: 2518 West Ranch St Carlsbad, CA IVR Number: 714665 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0212612018 02/26/2018 BLDG-14 049812-2018 Failed Michael Colllns Reinspection Complete Frame/Steel/Botting/ Weldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-18 Exterior 049811-2018 Falled Michael Collins Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLOG-Building Deficiency Not ready No 02/28/2018 02/2812018 BLDG-18 Exterior 050149-2018 Failed Michael Collins Reinspection Complete LathfDrywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No 03/05/2018 03/05/2018 BLDG~18 Exterior 050614-2018 Cancelled Michael Collins Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No 03/06/2018 03/0612018 BLDG-14 050615-2018 Failed Michael Colllns Reinspection Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Lath prelim not ready No BLDG-Building Deficiency Not ready No Checklist Item COMMENTS Passed BLDG-Building Deficiency Lath prelim No 0310712018 03/07/2018 BLDG-14 051178-2018 Partial Pass Michael Collins Reinspection Incomplete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency lath prelim not ready No BLOG-Building Deficiency Lath prelim at exterior, drops, Yes balconies/decks garages. see card. BLDG-Building Deficiency Not ready No 03/29/2018 03/29/2018 BLDG-84 Rough 053109-2018 Cancelled Mlchael Collins Reinspection Complete Combo(14,24,34,44) December 26, 2018 Page 4 of 10 PERMIT INSPECTION HISTORY REPORT (CB161996) ' ' Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPELL MONTECITO LLC Work Class: Apartments lssuo Date: 10/11/2016 Subdivisioti: Status· Closed -Finaled Expiration Date: 06/10/2019 Address: 2518 West Ranch St Carlsbad, CA IVR Number: 714665 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 02/05/2018 02/05/2018 BLDG-13 Shear 047772-2018 Cancelled Michael Collins Reinspectlon Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/06/2018 02/06/2018 BLDG-13 Shear 047930-2018 Failed Michael Collins Reinspectlon Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG•Building Deficiency Not ready No BLDG•Building Deficiency Not ready No 02/07/2018 02/07/2018 BLOG-14 048300-2018 Failed Michael Collins Reinspection Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Prelim frame at electrical chase No BLDG-Building Deficiency Cancelled per contractor No 02/09/2018 02/09/2018 BLDG-14 048349-2018 Partial Pass Chris Renfro Reinspection Incomplete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Prelim frame at electrical chase Yes BLDG•Building Deficiency Cancelled per contractor Yes 02/16/2018 02/16/2018 BLOG-14 049189-2018 Passed Michael Collins Complete Frame/Steel/Bolting/ Welding (Decks) Checklist ltom COMMENTS Passed BLDG-Building Deficiency Prelim frame at electrical chase Yes BLDG•Building Deficiency Electrical/Data closets Yes BLDG·Building Deficiency Cancelled per contractor No 02/21/2018 02/21/2018 BLOG-13 Shear 049387-2018 Cancelled Michael Collins Reinspection Complete Panels/HO (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/23/2018 02/23/2018 BLOG-13 Shear 049681-2018 Passed Paul Burnette Complete Panels/HO (Ok to wrap) December 26, 2018 Page 3 of 10 PERMIT INSPECTION HISTORY REPORT (C8161996) Pnrm1t Type· Work Class Status: Scheduled Date BLDG-Residential Apartments Closed -Finaled Actual Start Date Inspection Type Application DatP.: 05/19/2016 Owner: Issue Date: 10/11/2016 Subdivision: Expiration Date; 06/10/2019 Address: IVR Number: 714665 Inspection No. Inspection Status Primary Inspector 09/1812017 09/18/2017 BLDG-15 034954-2017 Cancelled Michael Collins Roof/ReRoof (Patio) Checklist Item COMMENTS BLDG-Building Deficiency Not ready 10/1312017 10/13/2017 BLDG-14 037530-2017 Cancelled Michael Collins Frame/Steel/Bolting/ Weldlng (Decks) Checklist Item COMMENTS BLDG-Building Deficiency Cancelled per contractor BLDG-15 037529-2017 Cancelled Michael Collins Roof/ReRoof {Patio) Checklist Item COMMENTS BLDG-Building Deficiency Cancelled per contractor BLDG-Building Deficiency Not ready 10/17/2017 10/17/2017 BLDG-16 Insulation 037987-2017 Passed Michael Collins Checklist Item COMMENTS BLOG-Building Deficiency HVAC platform prelim 01/11/2018 01/11/2018 BLDG-15 045625-2018 Passed Michael Collins Roof/ReRoof {Patio) Checklist Item COMMENTS BLDG-Building Deficiency Truss walk completed, see card for notes BLOG-Building Deficiency Cancelled per contractor BLDG-Building Deficiency Not ready 01118/2018 01/18/2018 BLDG-24 045870-2018 Passed Michael Collins Rough/Topout Checklist Item COMMENTS BLDG-Building Deficiency Waste/vent & roof drains 01/23/2018 01/2312018 BLDG-27 Shower 046759-2018 Partial Pass Michael Collins Pan/Tubs Checklist Item COMMENTS BLDG-Building Deficiency All units except 101, 1030,202,204 01124/2018 01/24/2018 BLDG-27 Shower 046750-2018 Passed Michael Collins Pan/Tubs Checklist Item COMMENTS BLDG-Building Deficiency Units 101,103,202,204 tub traps. 02/02/2018 02/02/2018 BLDG-13 Shear 047612-2018 Cancelled Michael Collins PanelslHD {ok to wrap) December 26, 2018 SHAPELL MONTECITO LLC 2518 West Ranch St Carlsbad, CA Reinspection Complete Reinspectlon Complete Passed No Reinspection Complete Passed No Reinspection Complete Passed No No Complete Passed Yes Complete Passod Yes No No Complete Passed Yes Reinspection Incomplete Passed Yes Complete Passed Yes Reinspection Complete Page 2 of 10 PERMIT INSPECTION HISTORY REPORT (CB161996) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPELL MONTECITO LLC Work Class: Apartments Issue Dato: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/10/2019 Address: 2518 West Ranch St Carlsbad, CA IVR Number: 714665 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 03/27/2017 03/27/2017 BLOG-22 017747-2017 Passed Michael Collins Complete Sewer/Water Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Underground waste to exterior of building Yes line only 03/29/2017 03/2912017 BLDG-21 018228-2017 Passed Michael Collins Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste to P.O.C. Yes 0410612017 04/06/2017 BLDG-11 019137-2017 Passed Mlchael Collins Complete Foundatlon/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Received PT & soils reports. Yes 06(08(2017 06/08/2017 BLDG-14 025848-2017 Passed Michael Collins Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd floor, floor sheathing drag nailing & CS Yes straps 07/18/2017 07/18/2017 BLDG-13 Shear 029077-2017 Cancelled Michael Collins Reinspection Complete Panels/HD (ok to wrap) Checklist ltem COMMENTS Passed BLOG-Building Deficiency No BLDG-14 029212-2017 Passed Michael Colllns Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 3rd floor drag nailing and CS straps Yes 09/11/2017 09/11/2017 BLDG-15 034245-2017 Falled Michael Colllns Reinspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLOG-Building Deficiency Not ready No 09/12/2017 09/12/2017 BLDG-15 034347-2017 Failed Mlchael Collins Re Inspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No December 26, 2018 Page 1 of 10 ,(~, RE CORD COPY ~ C ITY Of; CB161996 2518 WEST RANCH ST MONTEClTO: 13 UNlT APT CARLSBAD Building Division INSPECTION RECORD BLOG TYPE 1 / 14.924 SF APT AREA/ 2,447 SF GARAGE (BLDG #14) @ INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB RESDNTL APT Lot#: 1 ALLIANCE LAND PLANNING & @ CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION @ FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Cjlrfsbadca,goy/Buildjnq AND CLICK ON "Request Inspection" DATE: f\-I\-\LD ENGINEERING INC If "YES· is checked below that Division·s approval is required prior toJcqucsting a Final Building Inspection. If you have any questions please call the applicahle divi~ions at the phone numbers provided below. After all required approvals arc signed off-fax to 760-602 8560. email to hlr1gin,;pcctionsr,llc_arf.'!._h_ad_ca go_v or hring in a COPY of this card to: 1635 Faraday Ave. Carl!'-had. Required Prior to Requesting Building Final If Checked YES Planning/landscape 760-944-8463 Allow 48 hours CM&I (Engineering lrupec:tions) 760-438-3891 call before 2 pm Fire Prevemion 760-602-4660 Allow 48 hours #12 REINFORCED STEEL #66 MASONRY PRE GROUT □ GROUT □ WALL DRAINS #10 TILTPANELS #11 POUR SlltlPS #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME □ FLOOR □ CEILING #44 0 DUCT & PLENUM O REF. PIPING #15 ROOF SHEATHING #43 HEAT•AIR COND. SYSTEMS #13 EXT. SHEAR PANELS #16 IN.SULATION cooe n COMBO INSPECTION #18 EXTERIOR LATH #81 UNDERGROUND (U,12,21,311 #17 INTERIOR LATH & DRYWALL #82 DRYWALL,EXTLATH, GAS TES (17,18,23) #S1 POOL EXCA/STEEL/BOND /FtNCE #83 ROOFSHEATING, EXT SHEAR (13,15) #55 PREPLASTER/FINAL #84 FRAME ROUGH COMBO (14,24,34,44) 119 FINAL #85 T-Bar (14,24,34,44) ANAL OCCUPANCY (19,29,39,49) Date ln.s ector A/S UNDERGROUND VISUAL #27 A/S UNDERGROUND HYDRO #23 A/S UNDERGROUND FLUSH #25 A/S OVERHEAD VISUAL #28 A/S OVERHEAD HYDROSTATIC A/SANAL F / A ROUGH-IN F/AFINAL FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICETO ClfAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL REV 10/2012 SEE BACK FOR SPECIAL NOTES 11\ NOVA SvrviC'P.~ Daily Report Robertson's Ranch, Montecito Robertson\'s Ranch West Village Carlsbad , Ca Job#: 1016519 WEATHER Time Temp 07:04AM 57°F 12:03 PM 67°F GENERAL NOTES 11:15 AM Monica Hernandez Hum W-Dir 99% SSW 85% SSW W-Speed 2MPH SMPH Verified the reinforcing steel installation for bldg 14 foundation. Verified steel for size, grade, spacing and clearances. W-Gust 2MPH 9MPH Verified installation of Holddowns for size, grade, embedment and general locations. Thursday, Apr 06, 2017 Precip Condition 0 IN Mostly Cloudy 0 IN Partly Cloudy Note: At north side of stair, #5 "U" bars placed in shaded area where pt tendons are not placeable, were field bent to wide. Requires new bars installed to comply with clearance requirements at forms. Etivista was working on it at time of inspection. Will verify in the morning prior to concrete placement. Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Thursday, Apr 06, 2017 I Page 1 of 4 , . :: /f<_l}Af;jj}~. , qt !Ii/'-..\· ~ ••• ,,,~ ,\ I .... ' ~: } ~ ' ,.. . -~~ ~·~' ·,.: ... · -·, .. __ -.' ::.~ .. ~ .. , ·- , w .. -~ -, --~, t _;· .. :·~_. ,. f l . ... ·' -~,,. ,/· .. :.;· ! "'. '"!.I ,_ .... '"\ . . ,.•. -· ·' Ji TIME ARRIVAL 07: 10 AM Monica Hernandez Arrived onsite at 0700 on April 6, 2017. PERMIT NUMBERS 08:36 AM Monica Hernandez Permit#CB 161996. Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Thursday, Apr 06, 20171 Page 2 of 4 _ ...... :.-•1,,,,., ---.. MS,.,., ..-·----......... _ .... __ _ --~-......... ----'"'""-•-•.111 ..... _ ... ...,._ ... _ =:.:;...":::;:-•••-•• I -..... ~. _...-....... -.. -......... _ .... -~1. --•r-•----"·--·-= PRESTRESSED CONCRETE 11:17 AM Monica Hernandez Verified the installation of pt tendons for bldg 14 foundation. Verified tendons for size, grade, clearances, quantities, profile and hardware. All tendons in final place. ·~•~.--,· -z··~---.. -·. -_-__ · ··.· ---~---:-~-: . . ' ~~--.. ~r-:--•-"-..;·~ . . . ~ . . · . <.-. ·:-... •. -.. i: ~ .• , •. ;;. ~ .· --. ·~ t , ..... ' ·. .... t o6 -•• ',-•.•·· . ... . y· . :..._ ...:...:......• COMPLIANCE 12:55 PM Monica Hernandez All work is compliant with approved documents. TIME DEPARTED Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Thursday, Apr 06, 2017 1 Page 3 of 4 12:56 PM Monica Hernandez Departed at 1300 pm Employee Signature: Powered By NoteVault Nova Services. Inc. I Robertson's Ranch, Montecito I Thursday, Apr 06, 2017 J Page 4 of 4 Project Name: S\.\,~l 1At/l/, Project No.: Date: Report No.: ~,~SoOY\ \ '!> ~ot.J -O':f '2.D\".\--04-OS" Location: , ' Author. I~ Day: ( circle one) C,-o.'it(.. ~ vJ (~ 12.,.~" u<\sb-.J. ~~l"I Wt.tjNlf" M T@T F s s Client: Superintendent: Contractor. . Foreman: ft\\<6-T\W\ E.t, V,">t-... Soil Engineer. Geologist Weather: (circle one) B \-\4''tt.i"' R Wll."i'(\JJ('" "sunnv') Overcast Rainy Other: Unit'Phase/Lots: J Plan File No. Penni! No. ~""~\n'I •It CB I(, 1,,b -Observation Summary: Initials: 12-V,J.A.I A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at Date: "t/S {'Z,013: the site are substantially in conformance with those assumed in the geotechnical report. Initials: ~~ A representative of LGC Valley, Inc. observed the footing excavation(s). The footing Date: -'t/5/Ul:t excavation(s) extend into the proper bearing strata and are in general conformance with the recommendations of the geotechnical report. Initials: ~~w A representative of LGC Valley, Inc. measured the footing setback from the slope face. The Date: 4/'i/7,PI':/-setback was in general accordance with the recommendations of the geotechnical report. Initials: Date: Notes: 1. Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing the concrete. 2. Based on the expansion potential of the underlying soils, presoaking of soil below slabs may be recommended. Consult the geotechnical report for the presoaking recommendations. We note that clayey soils may take an extended period of time and the contractor should schedule accordingly. 3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e. heavy rain, a construction/placement delay, etc.), we should be contacted to perfonn additional site observations, as necessary. 4. Line and grade of the looting excavation(s) are not part of the purview of LGC Valley, Inc. 5. Soil compaction test results, including depth offill, relative compaction, bearing values, and soil expansion index test results are contained in the As-Graded Geotechnical Report provided at the completion of grading. ~a~~7'= her; I !S i,o I 1-\. 0 I Technician Hours Oat FOOTING OBSERVATION -:;-_.-·ived ~ ---p -LGC VALLEY, INC. SUMMARY " Geotechnical Consulting Print: White -File Copy Y elklw -Client Copy Pink -Field Copy Gold -Client'Agency Copy