Loading...
HomeMy WebLinkAbout2519 PALOMAR AIRPORT RD; 101; CB131984; Permit10-30-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB131984 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2519 PALOMAR AIRPORT RD CBADSt 101 Tl Sub Type COMM 2130201800 Lot# 0 $106,787 00 Construction Type 5B Reference # CYO PIZZA - 2,123 SF SHELL TO RESTAURANT Status Applied Entered By Plan Approved Issued Inspect Area Plan Check # ISSUED 08/15/2013 SKS 10/30/2013 10/30/2013 Applicant MELISSA YOUNG/JOSH AYER Owner COUNTY OF SAN DIEGO 2926 UPAS ST SAN DIEGO CA 760-519-4446 92104-4147 PUBLIC AGENCY 00000 Building Permit $723 06 Meter Size Add'l Building Permit Fee $0 00 Add'l Red Water Con Fee $0 00 Plan Check $506 14 Meter Fee $0 00 Add'l Building Permit Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $22 43 PFF (3105540) $1,943 52 Park Fee $0 00 PFF (4305540) $1,794 02 LFM Fee $0 00 License Tax (3104193) $0 00 Bridge Fee $0 00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $1,973 40 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $1,821 60 Renewal Fee $0 00 PLUMBING TOTAL $255 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $41 00 Other Building Fee $0 00 MECHANICAL TOTAL $73 65 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $722 26 Add'l Pot Water Con Fee $0 00 Redev Parking Fee $0 00 Reel Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SB1473) Fee $4 00 HMP Fee 9? Fire Expedidted Plan Review $0 00 Green Bldg Standards Plan Chk 99 TOTAL PERMIT FEES $9,880 08 Total Fees $9,880 08 Total Payments To Date $9,880 08 Balance Due-$0 00 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions fiereafler collectively refen-ed to as "fees/exactions" You have 90 days from the date this pennit was issued to protest imposition of these tees/exactions If you protest them, you must follovtf the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exadions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenwise ex[)ired THE FOLLOWING APPROVALS REQUIRED PRIOIPTO PERMITqSSUANCE ^ CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email builcling@carlsbadca gov PLANNING 1=1 ENGINEiRiNG Plan Check No. l^^^Y www carlsbadca gov Est. Value / Q ^ 1^1 Plan Ck. Deposit '^>0Q>, I*-/ Date SWPPP JOB ADDRESS 2519 Palomar Airport Rd SUiTE*/SPACE#/UNrr# 5-101 APN 213 - 020 - 18 - 00 CT/PROJECT H LOT# PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANr BUSINESS NAME CYO PIZZA CONSTR TYPE VB OCC GROUP A-2 DESCRIPTION OF WORK Include Square Feet of Affected Area(s) 2123 SQ. FT FOOD FACILITY TENANT IMPROVEMENT INCLUDING NEW PARTITIONS, PLUMBING, MILLWORK, RESTROOMS, OUTDOOR PATIO LAYOUT AND FIXTURES. EXISTING USE "N/A" PROPOSED USE RESTAURANT GARAGE (SF) N/A PATIOS (SF) 877 DECKS (SF) N/A FIREPLACE YESQ*-— NCfTI AIR CONDITIONING YES[7]NOQ FIRE SPRINKLERS YESFTINOI I APPLICANT NAME (Primary Contact} Josh Ayer APPLICANT NAME ISecondary Contact) Melissa Young ADDRESS 2926 Upas St ADDRESS 2926 Upas St CITY San Diego STATE CA 92104 CITY San Diego STATE CA 92104 PHONE 619-829-8846 FAX PHONE 760-51M446-FAX EMAIL josh@studiomyid.com PROPERTY OWNER NAME Grant Gottesman ADDRESS ^1 jTielissa@studiom^i^^ 2519 Palomar Airport Rd Suite 5-101 2^ A^BM AVH:. CITY Carlsbad STATE CA ZIP 92869 PHONE 619-454-9182 grantg@dinecrg.com ARCH/DESIGNER NAME & ADDRESS Baker Architecture STATE LIC # C28547 (Sec 70315 Business and Professions Code Any City or (^unty which requires a permit to construct alter, improve, demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s Licen<-.e Lavt {Chapter 9, commending v<ith Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) Workers' Compensation Declaration / hereby affirm under penalty of perjury one of the following tieclarations J have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Secton 3700 of the Labor Code, for the perfonnance of the work for which this perniit is issued [have and will maintain workers' compensation, as required by Si ction 3700 of the Labor Code for the perfbrniaQce of the tiork for which this pemiit is issued My y»orkeis' compensatign ipsurajice cfmer and policy number are Insurance Co 'SiTVfS p^AAP /') / jJ Policy No "^-Z-O ( Expiration Date _ CIS secton need not be completed if the perniit is' J Certificate of Exemption Icatifytliat California WARNING Failure addition to the cost of compensation, damages as] CONTRACTOR SIGNATURE the perf/r woriiSi isati^iniisumpre^^rier; [00) or less which this perniit is issued, I shall not employ any person in any manner so as to become subject to the Wori(ers' Compensaton Laws of ,1s unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollare (&100,000), in '06 of the Labor code, Interest and attorney's fees GENT DATE ©WrasiBaODDOIiBSIB ®{/CgQ,^II?(a'u'D®GOV / hereby affirm that I am exempt from Contractor's License Law for the following reason I I I, as owner of the property or my employees vrth vrages as their sole compensation, will do Ihe work and the stticture is not intended or offered for sale (Sec 7044, Business and Professions Code The Conlractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself tx through his own employees, provided that such improvements are not intended or offered for sale If, however Ihe building or improvement is sold within one year of completon, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) I I I, as owner of the property am exclusively confractng with licensed confractors to consbuct the project (Sec 7044, Business and Professions Code The Contactor's License Law does not apply to an owner of property viho builds or improves thereon, and contracts for such projects vrth confractor(s) licensed pursuant to the Contractor's License Law) [ I I am exempt under Secton Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials fbr constojcbon of the proposed property improvement I lYes I iNo 2 I (have / have not) signed an applicaton for a buikiing perniit for the proposed work 3 I have contacted with the folkiwing person (fimi) to provide Ihe proposed constucton (include name address / phone / contactors' license number) 4 I plan to provide portons of the woik, but I have hired the folknnng person to coonlinate, supervise and provide the major wori< (include name / address / phone / contactors' license number) 5 I will provide some of Ihe varit, but I have contacted (hired) Ihe following persons to provide the worit indicated (include name / address / phone / type of worts) vgfpROPERTY OWNER SIGNATURE •AGENT DATE (§®iKKPa@17ll. ffCaOS 8e®17'Q®C3 l?®(B Ca®(2l = ESSO®Sia'ffO<fttt, QQ0DQ,®0CIlO PSIBCBO'D'S (DGOSW," Is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registaton form or risk managempnt and preventon program under Sectons 25505,25533 or 25534 of Ihe Presley-Tanner Hazardous Substance Account AcP Yes No Is the applicant or futire building occupant required to obtain a perniit from the air polluton contol distict or air quality management disticP Yes No Is the fecility to be constucted within 1,000 feet of the outer boundary of a school site'' Yes '>^o IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the perfomiance of the work this pennit is issued {Sec 3097 (i) Civil Code) Lender's Name Lender's Address <ai?[pQ.O(gAi?a.ti' <gsiB'u'0(?0(g^^'u'D®{a IceitiiythatlhavereadttieappDcabonandstatettiatttieaboveinlbmiabonlsconGctandttiatttielnfbm lagieetocomplywitliallCityoidlnanoesandStatelawsrelatingtDbuildlngainstniclion I hereby aulhonze nepiesenlatve of the Qly of Carlsbad to enter upon Ihe above mentoned property for inspecton puiposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF (ii\RLSBAD AGAINST ALL UABIUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA penrat B required for excavatons over SO' deep and demoliton or constticton of stucluies over 3 stones in height EXHRATION Eveiy pemiit issued by the Building Offiaal under the provisions oMiSCode shall expire by limrtaton and become null and void if Die building or woik authonzed by such pemnit E not commenced wilhin 180 days from the date of such penrat or if the biding ^r woik authonzed by sufi\ gpmit B suspended or abandoned at any tme after Ihe woik is commenced for a penod of 180 days (Secton 106 4 4 Unifonn Building Code) ^efAPPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF OCCUPANCY (Commercial Projects Only] Fax (760) 602-8560, Email buildinolScarlsbadca gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008 C0# (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX ElVIAIL OCCUPANrs BUS LIC No DEUVERY OPnONS PICK UP- CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) MAIL TO CONTACT (Usted above) OCCUPANT (Usted above) CONTRACTOR (On Pg 1) MAIL/FAX TO OTHER ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION jef APPUCANT'S SIGNATURE DATE Inspection List Permits CB131984 Type Tl COMM Date 12/23/2013 12/20/2013 12/09/2013 12/03/2013 12/03/2013 12/02/2013 11/27/2013 11/22/2013 11/21/2013 11/14/2013 11/13/2013 11/13/2013 11/13/2013 11/08/2013 11/08/2013 11/06/2013 Inspection Item 89 Final Combo 89 Final Combo Final Combo Gas/Test/Repairs T-Bar Rough/Ducts/Dampers Rough/Ducts/Dampers Intenor Lath/Drywall Rough Combo Intenor Lath/Drywall Frame/Steel/Bolting/Weldin Rough/Topout Rough Electnc Intenor Lath/Drywall Rough/Ducts/Dampers Frame/Steel/Bolting/Weldin Inspector PD PD PD PD PD PB PD PD PD PD PD PD PD PB PB PD Act AP CO CO AP AP AP PA AP AP AP AP AP AP PA PA AP CYO PIZZA - 2,123 SF SHELL TO RESTAURANT Comments Thursday, February 13, 2014 Page 1 of 1 CARLSB^^^ INSPECTION RECORD Building Di<jision 0 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB B CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION EI FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.gov/Buildinq AND CLICK ON "Request Inspection" DATE: /n Sd /3 CB131984 2519 PALOMAR AIRPORT RD 101 CYO PIZZA - 2,123 SF SHELL TO RESTAURANT Tl COMM Lot# MELISSA YOUNG/JOSH AYER IF "YES:' IS CHECKED BELOW THAT DIVISION'S APPROVAL IS REQUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION. IF YOU HAVE ANY QUESTIONS PLEASE ^ALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW. AFTER ALL REQUIRED APPROVALS ARE SIGNED OFF- FAX TO 760-602-8560. EMAIL TO BLDGINSPECTI0NS@CARLSBADCA.GOV OR BRING IN A COPY OF THIS CARD TO: 1635 PARADAY AVE.. CARLSBAD. CA 92008. BUILDING INSPECTORS CAN BE REACHED AT 760-602-2700 BETWEEN 7:30 AM - 8:00 AM THE DAY OF YOUR INSPECTION. NO YES Required Prior to Requesting Building Final If Checked YES Date Inspector Notes ^/ Planning/Landscape 760-944-8463 Allow 48 hours V / CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm v/ Fire Preventfon 760-602-4660 Allow 48 hours / Type of Inspection Type of Inspection CODE # BUILDING Date Inspector [j^^^^^^^^^^^^^^^^^^^^H Date Inspector #11 FOUNDATION #31 •ELECTRICUNDERGROUND DUFER #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 B^LECTRIC SERVICE • TEMPORARY • GROUT • WALL DRAINS #35 PHOTOVOLTAIC #10 TILTPANELS #39 FINAL #11 POUR STRIPS CODE # MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS & PIPING // #14 SUBFRAME • FLOOR • CEILING #44 • DUCTS PLENUM • REF PIPING #15 ROOFSHEATHING #43 HEAT-AIR COND SYSTEMS #13 EXT. SHEAR PANELS #49 FINAL #16 INSULATION coDi # COMBO INSPECTION #18 EXTERIOR LATH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH & DRYWALL #82 DRYWALLEXT LATH, GAS TES (17,18,23) #51 POOLEXCA/STEEL/BOND/FENCE #83 ROOFSHEATING, EXT SHEAR (13,15) #55 PREPLASTER #84 FRAME ROUGH COMBO (14,24,34,44) #19 FINAL #89 FINAL OCCUPANCY (19,29,39,49) CODE # PLUMBING Date Inspector #22 • SEWER & BL/CO • PL/CO "• f . . - FfIRE • Date Inspector #21 UNDERGROUND OWASTE • WTR #24 TOP OUT DWASTE DWTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN /? A/S UNDERGROUND HYDRO #23 • GAS TEST • GAS PIPING /z • 5 A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL 7^/P9rC /^'V'/S #28 SOUR WATER A/S OVERHEAD HYDROSTATIC , #29 FINAL A/S FINAL coDs# STORMWATER F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN / #605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL O \o\^|l7 #609 NOTICE OF VIOLATION JWfiD4eftt«A3rPRESStmnESlY)^ \7^\ IO ll ^ #610 VERBALWARNING MEDICAL GAS FINAL REV 10/2012 SEE BACK FOR SPECIAL NOTES Section 5416. Health and Safety Code, State of California reof working at a (a) There shall be not less than one water closet for each 20 eniploye®rt0|o!lr|ctioaal construction job site The water closet shall consist of a patented chemicart^e^irefe^ (b) For the purpose of this section the term construction site shall mean the location on wPffch* citt&aFcoi building is in progress (c) A violation of this section shall constitute a misdemeanor Ail construction or work for which a permit is required shall be subject to inspection and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the inspector Work shall not be done beyond the point indicated m each successive inspection without first obtaining the approval of the inspector DATE ADDITIONAL NOTES rZ> -i-^l ^%7AJI^ jPt/r.r <;£^i> ^JC ~ fTiger^i/c "Tfo re>\ys^ c-ra/^ES^ ^/Q^ AJ/TW ^isy^/Aj&i^ Af^J/^:^ /L f< Ll .•)/v /-x C '1 -4^ City of Carlsbad Permit No Address VALUATION WORKSHEET Building Division Assessor parcel No. Date By J;-" . *Typ5iof4^o|k^ Mrea«f#irk Mul|fpl|er SFD and Duplexes $110 17 $0 00 Residential Additions $131 73 $0 00 Remodels / Lofts $57 48 $0 00 Apartments & Multi-family $98 20 $0 00 Garages/Sunrooms/Solariums $28 74 $0 00 Patio/Porch/Carport $9 58 $0 00 Enclosed Patio $15 51 $0 00 Decks/Balconies/Stairs $15 57 $0 00 Retaining Walls, concrete,masonry $19 16 $0 00 Pools/Spas-Gunite $40 72 $0 00 Tl/Stores, Offices $37 12 $0 00 Tl/Medical, restaurant, H occupancies 2,123 $50 30 $106,786 90 Photovoltaic Systems/ # of panels $400 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 Fire Sprinkler System $3 11 $0 00 Air Conditioning - commercial $5 03 $0 00 Air Conditioning - residential $4 19 $0 00 Fireplace/ concrete, masonry $3,855 98 $0 00 Fireplace/ prefabricated Metal $2,62134 $0 00 $0 00 $0 00 TOTAL Valuation: $106,787 Comm/Res (CIR): C Building Fee $723 06 Plan Check Fee $506 14 Strong Motion Fee $22 00 Green Bldg Stand Fee $4 00 Green Bldg PC Fee $0 00 License Tax/PFF $3,737 54 License Tax/PFF (in CFD) $1,943 52 CFD 1st hour of Plan Check Fire Expedite Plumbing Mechanical Electrical TBD TBD TBD $106,786 90 CFD 0 Yes {PFF= 1.82%) 0 No (PFF = 3 5%) Land Use Density Improve Area Fiscal Year Annex. Year Factor CREDITS PFF and/orCFD Explanation. EsGil Corporation In VartnersHi-p with government for (BuiCding Safety DATE 09/24/2013 • APPLICANT ^ JURIS JURISDICTION City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-1984 SET III PROJECT ADDRESS 2519 Palomar Airport Rd., Ste. 5-101 PROJECT NAME Cyo Pizza T. I. XI The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to ^ EsGil Corporation staff did not advise the applicant that the plan check has been completed I I EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Email Fax # Mail Telephone Fax In Person • REMARKS By Aaron Goodman Enclosures EsGil Corporation • GA • EJ • PC 09/19/2013 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (partnersfiip wttH government for (BuiCding Safety DATE 09/13/2013 OAE^ANT /-CTJURIS) JURISDICTION City of Carlsbad ^-prAN REVIEWER • FILE PLAN CHECK NO 13-1984 SET II PROJECT ADDRESS 2519 Palomar Airport Rd., Ste. 5-101 PROJECT NAME Cyo Pizza T. I. I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck ^ The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Josh Ayer 2926 Upas St, San Diego, CA 92104^ I I EsGil Corporation staff did not advise the applicant that the plan check has been completed EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Josh Ayer Telephone^619-829-8846 Date contacted 7 h f 13(by ) Email iosh(a)studiomvid com Fax # Mail^ Telephone Fax In Person • REMARKS By Aaron Goodman Enclosures EsGil Corporation • GA • EJ • PC 09/06/2013 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 13-1984 09/13/2013 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. 1 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted In one of two ways: 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete 2 All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code) 3 The 34 inch high counter along gridline F/G is noted correctly on sheet 1-10 0 Please correct sheet 1-6 0 1. Now, set II is incorrectly noted as 42 inches above the finished floor. Please correct. 2. Sheet 1-6.0: elevation 4/1-12.1 & 10/1-11.1 is missing. Please provide. 3. Sheet 1-6.0: Note 8 shown at the transaction counter and at the counter along gridline F/G incorrectly calls out the counter height as 42 inches. Please correct. 4. Sheet 1-6.0: The elevation called out at the transaction counter, 1.2/1-12.0 is missing. Please provide showing the correct height of 34 inches. 11 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc 12 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please bneflv descnbe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate • Yes • No The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Dnve, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Aaron Goodman at Esgil Corporation Thank you EsGil Corporation In (Partnership witfi government for (BuiCding Safety DATE 08/28/2013 ayXPPLICANT ja JURIS JURISDICTION City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-1984 SET I PROJECT ADDRESS 2519 Palomar Airport Rd., Ste. 5-101 PROJECT NAME Cyo Pizza T. I. I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck Xl The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X The applicant's copy of the check list has been sent to Josh Ayer 2926 Upas St, San Diego, CA 92104 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed X EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Josh Ayer Telephone # 619-829-8846 Date contacted ^| 2>^ (by Email iosh(a)studiomvid com Fax # ^(^yiail 'v Telephone Fax In Person • REMARKS By Aaron Goodman Enclosures EsGil Corporation • GA • EJ • PC 08/19/2013 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 13-1984 08/28/2013 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 13-1984 JURISDICTION City of Carlsbad OCCUPANCY A-2 USE Restaurant TYPE OF CONSTRUCTION V-B ACTUAL AREA 2123 ALLOWABLE FLOOR AREA NA STORIES 1 HEIGHT SPRINKLERS'? Yes OCCUPANT LOAD 86 REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE PLANS RECEIVED BY ESGIL CORPORATION 08/19/2013 DATE INITIAL PLAN REVIEW COMPLETED 08/28/2013 PLAN REVIEWER Aaron Goodman FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department, Fire Department or other departments Clearance from those departments may be required pnor to the issuance of a building permit Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 13-1984 08/28/2013 1 Please make all corrections, as requested in the correction list Submit FOUR new complete sets of plans for commercial/industnal projects (THREE sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete 2 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) 3 The 34 inch high counter along gndline F is noted correctly on sheet 1-10 0 Please correct sheet 1-6 0 4 Sheet 1-6 0 Note 16 on this sheet refers to detail #1/1-13 1 Please provide 5 All doors and gates, within the exit path to a public way from an occupancy of Group A occupant load of 50 or more shall not be provided with latches or locks unless they are equipped with panic hardware Please show compliance at the gate from the patio Sections 1008 1 10 and 1002 6 Glazing in the following locations should be of safety glazing matenal in accordance with Section 2406 4 (see exceptions) a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface 7 The conductors from new panel "B" to panel "A" appear to be undersized based on the 200A overcurrent device Please correct (Should have been 3/0"?) 8 The rating of the bus at panel "A" at the top nght corner of sheet El appears to be undersized If this should be 400A please correct or change the call-out in detail 2 City of Carlsbad 13-1984 08/28/2013 9 GFCI protected receptacle outlets are required within 25 feet of all mechanical equipment (heating, air-conditioning and refrigeration equipment) Please show on plans NEC 210 63 10 The Plumbing plans are inconsistent with the architectural plans Please review and correct the fixtures being called out and gpf requirements of CPC Chapter 4 See 402 2 2 and 402 3 2 11 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc 12 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate • Yes • No The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Dnve, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Aaron Goodman at Esgil Corporation Thank you City of Carlsbad 13-1984 08/28/2013 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 13-1984 PREPARED BY Aaron Goodman DATE 08/28/2013 BUILDING ADDRESS 2519 Palomar Airport Rd., Ste. 5-101 Set I BUILDING OCCUPANCY A-2 TYPE OF CONSTRUCTION V-B Sprinklered BUILDING PORTION AREA (Sq Ft) Valuation Multiplier Reg Mod VALUE ($) T 1 2123 , 3rT2 78,806 Air Conditioning Fire Spnnklers TOTAL VALUE 78,806 Jurisdiction Code cb By Ordinance Bldg Permit Fee by Ordinance • $592 72 Plan Check Fee by Ordinance Type of Review I I Repetitive Fee Repeats IZI Complete Review • Other |—I Hourly EsGil Fee • Structural Only Hr $385.27 $331 92 Comments Sheet 1 of 1 macvalue doc + CITY OF CARLSBA! PLAN CHECK REVIEW TRANSIVIITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE:09/11/13 PROJECT NAME: PALOMAR COMMONS PROJECT ID: CB 13-1984 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2519 PALOIVIAR AIRPORT RD BLDG 5 APN: VALUATION: $106,787 / This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: KATHLEEN LAWRENCE 09/11/13 A Final Inspection by the Division is required ' Jves L?JNO This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: JOSH@STIDIOMYID.COIVI You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from al! divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked. O-'-v 'r^'ENGINEERrNG?:i. m '""- iii--760.-602-2750-.*^ ' '*;|FIRE-PREVENTI0N:^|: h '•• .r:>JC760-602-4665**j'^*~ 'i* ; Chris Sexton 760-602-4624 Chris Sexton@carisbadca gov / Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov I " 1 Greg Ryan 760-602-4663 Gregorv Ryan®carlsbadca gov Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov ; i Linda Ontiveros —J 760-602-2773 Linda Ontiveros@carlsbadca gov Cindy Wong - 760-602-4662 Cvnthia Wong@carlsbadca gov 1 \ I Dominic Fieri ^ 760-602-4664 Dommic Fieri@carlsbadca gov Remarks: ^ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www carlsbadca gov ENGINEERING Plan Check for CB 13-1984 Date 09/11/13 Project Address 2519 PALOMAR AIRPORT RD BLDG 5 APN „ * Tl CYO PIZZA PALOIVIAR COMMONS Project Description INCLUDES 877 SF OF PATIO Valuation $106,787 ENGINEERING Contact Kathleen Lawrence Phone 760-602-2741 Email kathleen.lawrence@carlsbadca.gov Fax 760-602-1052 RESIDENTIAL INTERIOR [Z] TENANT IMPROVEMENT • RESIDENTIAL ADDITION MINOR (<$20,000.00) • PLAZA CAMINO REAL L J CARLSBAD PREMIER OUTLETS COMPLETE OFFICE BUILDING OTHER: PCR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY KATHLEEN LAWRENCE REMARKS- FEES ATTACHED- DATE 09/11/13 Notification of Engineering APPROVAL has been sent to J0SH@STIDI0MYID.COM via EMAIL on 09/11/13 E-36 Page 1 of 1 REV 4/30/11 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by K LAWRENCE Date 09/11/13 Address 2519 PALOMAR AIRPORT RD BLDG 5 Fees Update by KiL Date 09/11/13 Fees Update by GEO DATA: LFMZ: / B&T: Bldg Permit # CB 13-1984 Date 09/11/13 EDU CALCULATIONS: List types and square footages for all uses Types of Use CYO PIZZA Types of Use Types of Use Types of Use Sq Ft /Units 877 SF Sq Ft /Units Sq Ft /Units Sq Ft /Units ADT CALCULATIONS' List types and square footages for all uses EDU's EDU's EDU's EDU's 42 SEATS INSIDE PAID FOR ONLY CHARGED FOR 21 SEATS (lODA) Types of Use CYO PIZZA Types of Use Types of Use Types of Use Sq Ft/Units 877 SF Sq Ft/Units Sq Ft/Units ADT's Sq Ft/Units ADT's FEES REQUIRED 40O SF OF PATIO ALLOWED W/NO FEE FEE'D 477 SF Within CFD [lYES (no bndge & thoroughfare fee in District #1, reduces Traffic Impact Fee) fjNO 1 PARK-IN-LIEU FEE ["!NW QUADRANT QNE QUADRANT QSE QUADARANT LlSW QUADRANT ADT's. 877 ADT's INSIDE PAID FOR ADT'S/UNITS I X FEE/ADT 2TRAFFICIMPACT FEE 'kin-^00 =- </7 7/^»' ADT'S/UNITS 33 | X FEE/ADT $115 3 BRIDGES THOROUGHFARE FEE ADT'S/UNITS f< 4 FACILITIES MANAGEMENT FEE ADT'S/UNITS I X 5 SEWER FEE % El DIST #1 FEE/ADT ZONE FEE/SQ FT /UNIT I =$ N/A =$ 3795 • DIST #2 |=$ N/A • 0 J DIST #3 EDU's-5^ X FEE/EDU 842 BENEFIT AREA: G t^cj EDU's-W ' I X 6 DRAINAGE FEES PLDA ACRES I X 7 POTABLE WATER FEES UNITS CODE CONN FEE FEE/EDU 632 •HIGH FEE/AC • MED METER FEE =$ N/A =$ 477414' 3o5 6.9 =$-3583^4-. UM [ZjLOW =$ PD SDCWA FEE • • • TOTAL PLANNING DIVISION BUILDING PLAN CHECK Development Services Planning Division ^ (-T Y OF APPROVAL 1635 Faraday Avenue CARL SBAD P-29 (760) 602-4610 www carlsbadca eov DATE: 8/19/13 PROJECT NAME: CYO PIZZA PROJECTID: PLAN CHECK NO: CB131984 SET#: ADDRESS: 2519 PALOMAR AIRPORT RD APN: XI This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required • Yes No Vow may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. [J This plan check review is NOT COIVIPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: J0SH@STUDI0IVIYID.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING , 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665,, 1 1 Chris Sexton 760-602-4624 Chris Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 1 Greg Ryan 760-602-4663 Gregory Rvan@carlsbadca gov Gina Ruiz 760-602-4675 Gma RuizOcarlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov 1 1 Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dominic Fieri@carlsbadca gov Remarks Per project planner, Bldg 5 outdoor eating area is for entire center as there is an overage of 20 prkg spcs (fenced/walled off for serving alcohol ok) and plans state no new roof mounted equipment and the HVAC IS all existing ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 10/20/13 PROJECT NAME: cyo pizza PROJECT ID: PLAN CHECK NO: cbl31984 SET#: lil ADDRESS: 2519 PAR APN: • This plan check review is complete and has been APPROVED by the fire Division. By: cwong A Final Inspection by the Division is required |^ ves • No ^ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: IVIelissa@studiomyid.com (and via usps) You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked. PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chns Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov Q Greg Ryan 760-602-4663 Gregory Ryan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov X Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca gov Remarks: 10/20/13 Page 1 of 4 ***Bubble All Changes*** 1. Sheet 1-1.0: Current codes on 1-1.0: Did not add California Fire Code to list of applicable codes 2 In reference to note #7 on sheet 1-2 1: this is not verbatim as stated in section 10081.9.3 of CBC and CFC, 2010 edition. The word "mam" has been omitted. This interpretation now could mean all exterior doors and not "mam". Revise. 3. Reference #2 above. Not both doors need to be equipped with panic type hardware "IVIam" exterior door or doors (if double-leafed) maybe if requirements of #2 of section 1008.1.9.3 are met. 4 There is no delta 3 on sheet E2 as stated. Please clarify. 5. Provide cut sheets for: patio heaters, awning and umbrella materials. 6 Justify egress for patio area. 7. Provide proof of approval for enclosing access to Fire Department Riser Room and Fire Alarm Control Panel Room. Provide written approval form SDGE for enclosing access to SDGE room too. 8. Sheet 11.9: WDl: In Flame Seal test report #3127494SAT-001. Does the test specimen match material WDl? 9 Sheet 11.9: Is the purpose (section II) of the aforementioned test congruent with the use and application of the charred wood (WDl)? 10 Sheet 1-1.2, #2: PLl or similar shall not obstruct sprinkler coverage per NFPA 13 requirements. 10/2/13 ***Bubble All Changes*** The majority of corrections were not addressed in Fire Set III. A copy of corrections accompanied the resubmittal with comments in red for corrections The comments or corrections stated as made were not found on Fire Set III. Please see results below: 1 Sheet 1-1.0 State current codes this project references for design and construction. **NOT FOUND ON 4/1-1.0** 2. Sheet 1-10: Occupant load not given/N/A for outdoor seating area However the outdoor seating area is 50. If enclosed, the patio shall have an occupant load calculation as if it were interior. Recalculate Indicate fixed or non- fixed seating in calculations. **PLEASE JUSTIFY FROM CFC TABLE 1004.1 OCCUP LOAD FACTOR OF 50 USED. THIS SHOULD BE 15. RECALCULATE UNLESS THIS IS A LAB, GYMNASIUM, LIBRARY OR SIMILAR. 3. Sheet 1-20: Mechanical Notes: Add the following or similar: Air moving systems supplying air in excess of 2000 cubic feet/mmute shall be equipped with smoke duct detectois and be tied m to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC section 608 and NFPA 72. **THERE IS NO #9 ON MECHANICAL 1-2.0 4. Sheet 1-2.1: Add the following or similar. "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic spnnklers and wet and dry standpipes, inert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carisbad Fire Department for review and approval PRIOR to installation. (CFC 9012)" Page 2 of 4 ** THERE IS NO #29 ON ENTIRE SHEET 1-2.1** 5. Sheet 1-2.1: Fire Notes: We are currently in the CBC and CFC, 2010 edition, NOT UBC. Please update references made to the UBC (#7,10,16,18, etc.) to reflect correct and current code in CBC or CFC. **ALL NOTES REFERENCED ABOVE WERE NOT REVISED** 6. Sheet 1-4.0: Specify door hardware for door 102. **IT IS NOTED THAT BOTH FRONT AND BACK DOOR HAVE THE SAME HARDWARE. ARE BOTH DOUBLE KEY LOCKED WITH SIGN ABOVE?** 7. Sheet 1-9.1: Provide manufacturer's cut sheet for wood panels. **CONFIRM THAT THESE WOOD PANELS ARE FLOOR FINISH. IF INTERIOR FINISH, PROVIDE CUT SHEETS THAT SHOW COMPLIANCE WITH CBC 803.9 FOR FLAME INDEX** 8. Sheet H: Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department. If this is needed for reference, please state so and it may remain. **COMPLETE** 9. Sheet E2 and 1-7.0: The following requirement for emergency lighting shall be met. Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge. The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011. Indicate on reflective ceiling AND electrical sheets. **ONLY NOTES ADDED - NO CHANGE ON PLAN - ADD REQUIRED EM LIGHTS OR SUBMIT A PHOTOMETRIC PLAN FOR JUSTIFICATION** 10. Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code **NOTDONE** 9/4/2013 *** Bubble All Changes *** *** Bubble all Changes *** 1. Sheet 1-1.0 State current codes this project references for design and construction. 2. Sheet 1-10: Occupant load not given/N/A for outdoor seating area. However the outdoor seating area is 50. If enclosed, the patio shall have an occupant load calculation as if it were intenor. Recalculate. Indicate fixed or non- fixed seating in calculations. 3. Sheet 1-20. Mechanical Notes: Add the following or similar Air moving systems supplying air in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC section 608 and NFPA 72. Page 3 of 4 4. Sheet 1-2 1: Add the following or similar: "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry standpipes; iner^halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation. (CFC 901.2)" 5. Sheet 1-2.1: Fire Notes: We are currently in the CBC and CFC, 2010 edition, NOT UBC Please update references made to the UBC (#7,10,16,18, etc) to reflect correct and current code in CBC or CFC. 6 Sheet 1-4.0: Specify door hardware for door 102 7. Sheet 1-9.1: Provide manufacturer's cut sheet for wood panels. 8. Sheet H: Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department. If this is needed for reference, please state so and it may remain. 9. Sheet E2 and 1-7.0: The following requirement for emergency lighting shall be met Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below withm the exit access, exit and exit discharge. The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011. Indicate on reflective ceiling AND electncal sheets. 10. Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code. Page 4 of 4 CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 9/4/13 PROJECT NAIVIE: cyo pizza PLAH CHECK NO: cbl31984 SET#: II PROJECT 1 ADDRESS: 2519 PAR APN: Q This plan check review is complete and has been APPROVEl^y the fire Division. By: cwong f\ A Final Inspection by the Division is required ^ Yes • NHS^ 3 This plan check review is NOT COIVIPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: IVIelissa@studiomyid.com (and via usps) You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clanfications on the attached checklist please contact the following reviewer as marked. PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chris Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@car[sbadca gov 1 1 Greg Ryan 760-602-4663 Gregorv Ryan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carisbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov X Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca gov Remarks: 9/4/2013 *** Bubble All Changes *** Page 1 of 2 *** Bubble all Changes *** 1. Sheet 1-10 State current codes this project references for design and construction. 2. Sheet 1-1.0: Occupant load not given/N/A for outdoor seating area However the outdoor seating area is 50 If enclosed, the patio shall have an occupant load calculation as if it were intenor. Recalculate Indicate fixed or non- fixed seating in calculations. 3. Sheet 1-20: Mechanical Notes: Add the following or similar- Air moving systems supplying air in excess of 2000 cubic feet/mmute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC section 608 and NFPA 72. 4. Sheet 1-2 1: Add the following or similar: "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry standpipes; inert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation. (CFC 901.2)" 5. Sheet 1-2.1: Fire Notes: We are currently in the CBC and CFC, 2010 edition, NOT UBC Please update references made to the UBC (#7,10,16,18, etc) to reflect correct and current code in CBC or CFC. 6. Sheet 1-4.0: Specify door hardware for door 102. 7. Sheet 1-9.1: Provide manufacturer's cut sheet for wood panels. 8. Sheet H: Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department If this is needed for reference, please state so and it may remain 9. Sheet E2 and 1-7 0 The following requirement for emergency lighting shall be met. Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge. The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011 Indicate on reflective ceiling AND electrical sheets. 10. Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code. Page 2 of 2 Carlsbad Fire Department Plan Review Requirements Category TI, COMM Date of Report- 09-04-2013 Reviewed by ^A A_)~^ Name MELISSA YOUNG/JOSH AYER Address 2926 UPAS ST SAN DIEGO CA ^ 92104-4147 Permit # CBI31984 Job Name CYO PIZZA - 2,123 SF SHELL TO Job Address 2519 PALOMAR AIRPORT RD CBAD St 101 INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval Conditions: Cond CON0006618 [NOT MET] *** Bubble all Changes *** 1. Sheet 1-10 State current codes this project references for design and construction 2. Sheet 1-1.0. Occupant load not given/N/A for outdoor seating area However the outdoor seating area is 50 If enclosed, the patio shall have an occupant load calculation as if it were interior Recalculate. Indicate fixed or non-fixed seating in calculations 3 Sheet 1-20 Mechanical Notes Add the following or similar Air moving systems supplying air m excess of 2000 cubic feet^minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required CMC section 608 and NFPA 72 4 Sheet 1-2 1 • Add the following or similar- "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry standpipes, inert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation (CFC 901 2)" 5 Sheet 1-2 1 Fire Notes. We are currently in the CBC and CFC, 2010 edition, NOT UBC. Please update references made to the UBC (#7,10,16,18, etc ) to reflect correct and current code in CBC or CFC. 6. Sheet 1-4 0 Specify door hardware for door 102 7. Sheet 1-9. T Provide manufacturer's cut sheet for wood panels 8 Sheet H Remove all references to ansul system This shall be a deferred submittal directly to the Carlsbad Fire Department If this is needed for reference, please state so and it may remain 9. Sheet E2 and 1-7.0 The following requirement for emergency lighting shall be met. Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011. Indicate on reflective ceiling AND electrical sheets 10 Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code Entry 09/04/2013 By cwong Action CO Carlsbad Fire Department Plan Review Requirements Category TI, COMM Date of Report 10-20-2013 Reviewed by. Name: MELISSA YOUNG/JOSH AYER Address: 2926 UPAS ST SAN DIEGO CA 92104-4147 Permit #. CB131984 Job Name CYO PIZZA - 2,123 SF SHELL TO Job Address. 2519 PALOMAR AIRPORT RD CBAD St 101 INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval Conditions; Cond- CON0006618 [NOT MET] *** Bubble all Changes *** 1. Sheet 1-10 State current codes this project references for design and construction 2 Sheet 1-1.0- Occupant load not given/N/A for outdoor seating area However the outdoor seating area is 50 If enclosed, the patio shall have an occupant load calculation as if it were interior Recalculate. Indicate fixed or non-fixed seating in calculations 3 Sheet 1-20 Mechanical Notes Add the following or similar. Air moving systems supplying air in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system If no fire alarm is present, then an audible, local alarm shall be required CMC section 608 and NFPA 72. 4. Sheet 1-2 1: Add the following or similar- "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry standpipes, inert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation (CFC 901.2)" 5 Sheet 1-2.1. Fire Notes We are currently in the CBC and CFC, 2010 edition, NOT UBC Please update references made to the UBC (#7,10,16,18, etc.) to reflect correct and current code in CBC or CFC 6 Sheet 1-4 0 Specify door hardware for door 102 7. Sheet 1-9 1. Provide manufacturer's cut sheet for wood panels 8 Sheet H: Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department If this is needed for reference, please state so and it may remain 9. Sheet E2 and 1-7 0 The following requirement for emergency lighting shall be met Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1-foot candle at the walking surface CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011 Indicate on reflective ceiling AND electrical sheets. 10. Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, m accordance with the Business and Professions Code Entry: 09/04/2013 By. cwong Action-CO Cond: CON0006668 [NOT MET] ***Bubble All Changes*** The majority of corrections were not addressed in Fire Set III A copy of corrections accompanied the resubmittal with comments in red for corrections. The comments or corrections stated as made were not found on Fire Set III Please see results below- 1. Sheet 1-1.0 State current codes this project references for design and construction **NOT FOUND ON 4/1-1 0** 2 Sheet 1-10 Occupant load not given/N/A for outdoor seating area However the outdoor seating area is 50 If enclosed, the patio shall have an occupant load calculation as if it were interior. Recalculate Indicate fixed or non-fixed seating in calculations. **PLEASE JUSTIFY FROM CFC TABLE 1004 1 OCCUP LOAD FACTOR OF 50 USED THIS SHOULD BE 15 RECALCULATE UNLESS THIS IS A LAB, GYMNASIUM, LIBRARY OR SIMILAR. 3 Sheet 1-20. Mechanical Notes Add the following or similar Air moving systems supplying air in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system If no fire alarm is present, then an audible, local alarm shall be required CMC section 608 and NFPA 72 **tHERE IS NO #9 ON MECHANICAL 1-2 0 4 Sheet 1-2.1. Add the following or similar- "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry standpipes; inert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation (CFC 901.2)" ** THERE IS NO #29 ON ENTIRE SHEET 1-2 1** 5. Sheet 1-2 1 Fire Notes We are cuiTently in the CBC and CFC, 2010 edition, NOT UBC. Please update references made to the UBC (#7,10,16,18, etc) to reflect correct and current code in CBC or CFC **ALL NOTES REFERENCED ABOVE WERE NOT REVISED** 6 Sheet 1-4 0: Specify door hardware for door 102 **IT IS NOTED THAT BOTH FRONT AND BACK DOOR HAVE THE SAME HARDWARE ARE BOTH DOUBLE KEY LOCKED WITH SIGN ABOVE*^** 7. Sheet 1-9.1 Provide manufacturer's cut sheet for wood panels **CONFIRM THAT THESE WOOD PANELS ARE FLOOR FINISH IF INTERIOR FINISH, PROVIDE CUT SHEETS THAT SHOW COMPLIANCE WITH CBC 803 9 FOR FLAME INDEX** 8 Sheet H. Remove all references to ansul system This shall be a deferred submittal directly to the Carlsbad Fire Department. If this is needed for reference, please state so and it may remain **COMPLETE** 9. Sheet E2 and 1-7 0. The following requirement for emergency lighting shall be met. Furniture placement shall be considered m the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied The means of egress illumination level shall not be less than 1-foot candle at the walking surface CFC 1006 Illuminated exit signs and egress lighting shall be placed m accordance with CFC 1011 Indicate on reflective ceiling AND electrical sheets **ONLY NOTES ADDED - NO CHANGE ON PLAN - ADD REQUIRED EM LIGHTS OR SUBMIT A PHOTOMETRIC PLAN FOR JUSTIFICATION** 10 Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code. **NOT DONE** Entry. 10/02/2013 By CWONG Action CO Cond CON0006721 [NOT MET] ***Bubble All Changes*** 1 Sheet I-l.O • Current codes on I-l.O: Did not add California Fire Code to list of applicable codes 2. In reference to note #7 on sheet 1-2.1 - this is not verbatim as stated in section 1008 1 9 3 of CBC and CFC, 2010 edition The word "main" has been omitted This interpretation now could mean all exterior doors and not "main" Revise 3. Reference #2 above. Not both doors need to be equipped with panic type hardware "Main" exterior door or doors (if double-leafed) maybe if requirements of #2 of section 1008 1 9 3 are met. 4 There is no delta 3 on sheet E2 as stated. Please clarify 5. Provide cut sheets for. patio heaters, awning and umbrella materials 6 Justify egress for patio area. 7 Provide proof of approval for enclosing access to Fire Department Riser Room and Fire Alarm Control Panel Room Provide written approval form SDGE for enclosing access to SDGE room too 8. Sheet II .9: WDl In Flame Seal test report #3127494SAT-001 Does the test specimen match material WD P 9 Sheet II 9- Is the purpose (section II) of the aforementioned test congruent with the use and application of the charred wood (WDl)*^ 10 Sheet 1-1.2, #2 PLl or similar shall not obstruct sprinkler coverage per NFPA 13 requirements Entry. 10/20/2013 By cwong Action: CO Carlsbad Fire Department Plan Review Requirements Category TI, COMM Date of Report. 10-02-2013 Reviewed by: Oj A Name: MELISSA YOUNG/JOSH AYER Address- 2926 UPAS ST SAN DIEGO CA 92104-4147 Permit #. CBI31984 Job Name: CYO PIZZA - 2,123 SF SHELL TO Job Address- 2519 PALOMAR AIRPORT RD CBAD St: 101 INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval Conditions: Cond. CON0006618 [NOT MET] *** Bubble all Changes *** 1 Sheet 1-10 State current codes this project references for design and construction. 2 Sheet 1-10- Occupant load not given/N/A for outdoor seating area However the outdoor seating area is 50 If enclosed, the patio shall have an occupant load calculation as if it were interior. Recalculate. Indicate fixed or non-fixed seating in calculations. 3 Sheet 1-20: Mechanical Notes Add the following or similar: Air moving systems supplying air in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied m to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC section 608 and NFPA 72. 4 Sheet 1-2 1 Add the following or similar "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry standpipes, mert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation (CFC 901 2)" 5 Sheet 1-2 ] Fire Notes. We are currently m the CBC and CFC, 2010 edition, NOT UBC Please update references made to the UBC ( #7,10,16,18, etc.) to reflect correci and current code in CBC or CFC 6. SheetT-4.0: Specify door hardware for door 102. 7. Sheet 1-9.1 Provide manufacturer's cut sheet for wood panels. 8 Sheet H Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department. If this is needed for reference, please state so and it may remain 9. Sheet E2 and 1-7.0 The following requirement for emergency lighting shall be met. Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011. Indicate on reflective ceiling AND electrical sheets. 10. Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code. Entry: 09/04/2013 By. cwong Action-CO Cond. CON0006668 [NOT MET] ***Bubble All Changes*** The majority of corrections were not addressed in Fire Set III. A copy of corrections accompanied the resubmittal with comments in red for corrections. The comments or corrections stated as made were not found on Fire Set III Please see results below- 1 Sheet 1-10 State current codes this project references for design and construction **NOT FOUND ON 4/1-1.0** 2 Sheet 1-1.0- Occupant load not given/N/A for outdoor seating area. However the outdoor seating area is 50. If enclosed, the patio shall have an occupant load calculation as if it were interior Recalculate. Indicate fixed or non-fixed seating in calculations **PLEASE JUSTIFY FROM CFC TABLE 1004 1 OCCUP LOAD FACTOR OF 50 USED. THIS SHOULD BE 15. RECALCULATE UNLESS THIS IS A LAB, GYMNASIUM, LIBRARY OR SIMILAR 3 Sheet 1-20 Mechanical Notes: Add the following or similar: Air moving systems supplying air in excess of 2000 cubic feet/mmute shall be equipped with smoke duct detectors and be tied in to the buildmg fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC section 608 and NFPA 72. **tHERE IS NO #9 ON MECHANICAL 1-2.0 4. Sheet 1-2 1. Add the following or similar: "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry standpipes; mert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation (CFC 901 2)" ** THERE IS NO #29 ON ENTIRE SHEET 1-2.1 ** 5. Sheet 1-2.1. Fire Notes: We are currently in the CBC and CFC, 2010 edition, NOT UBC. Please update references made to the UBC (#7,10,16,18, etc.) to reflect correct and current code in CBC or CFC. **ALL NOTES REFERENCED ABOVE WERE NOT REVISED** 6. Sheet 1-4.0- Specify door hardware for door 102 **IT IS NOTED THAT BOTH FRONT AND BACK DOOR HAVE THE SAME HARDWARE. ARE BOTH DOUBLE KEY LOCKED WITH SIGN ABOVE'^** 7 Sheet 1-9 1: Provide manufacturer's cut sheet for wood panels. **CONFIRM THAT THESE WOOD PANELS ARE FLOOR FINISH IF INTERIOR FINISH, PROVIDE CUT SHEETS THAT SHOW COMPLIANCE WITH CBC 803.9 FOR FLAME INDEX** 8. Sheet H. Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department If this is needed for reference, please state so and it may remain **COMPLETE** 9 Sheet E2 and 1-7 0- The following requirement for emergency lighting shall be met Furniture placement shall be considered m the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge The means of egress, including the exit discharge, shall be lUxominated at all times the space served by the means of egress is occupied The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011 hidicate on reflective ceiling AND electncal sheets. **ONLY NOTES ADDED - NO CHANGE ON PLAN - ADD REQUIRED EM LIGHTS OR SUBMIT A PHOTOMETRIC PLAN FOR JUSTIFICATION** 10 Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, m accordance with the Business and Professions Code. **NOT DONE** Entry- 10/02/2013 By: CWONG Action: CO Janet Altar From. Sent: To: Subject: Josh Ayer <josh@studiomyid com> Wednesday, November 27, 2013 10 08 AM Building Fwd CYO Pizza - CB131984 - Charred wood fire rating test Forwarded message - From Gregory Ryan <Gregory Rvan(g),carlsbadca gov> Date Tue, Nov 26, 2013 at 6 33 AM ^ , Subject RE CYO Pizza - CB131984 - Charred wood fire rating test "*^Oi^ To Josh Aver <iosh@studiomvid com> Cc Melissa Young <melissa(g),studiomvid com>, Cynthia Wong <Cvnthia Wong(a),carlsbadca gov> 0/>, Josh- Thanks again for the test data sheets I have approved these two materials for installation in accordance with their listing You may want to arrange a time to 'slip-sheet' the plans with the Building Department GREGORY L RYAN Deputy Fire Marshal Carisbad Fire Department 1635 Faraday Avenue Carlsbad CA 92008 760 602 4663 Gregory RvantScarlsbadca gov From: Josh Ayer [mailto-josh(astudiomyid com] Sent: Monday, November 25, 2013 09.56 To: Gregory Ryan Cc: Melissa Young Subject: CYO Pizza - CB131984 - Charred wood fire rating test Good Morning Greg, Attached are the final reports from Intertek for the charred wood fire rating for CYO Pizza Can you please let us know if this material is approved on your end. Once approved, we will slip sheet our revised finish schedule into the permitted set Thank you. Josh Ayer Designer StudioMYID 2926 Upas Street San Diego, CA 92104 619 829 8846 |osh(a)studiomvid com www studiomyid com Raenelle Abbey Fromt lenftt Tot Cct lubjeclt Josh Ayer <josh@studiomyid.com> Thursday, October 10,2013 9:24 AM Cynthia Wong; Melissa Voung Janet Altar; Raenette Abbey Re: CB131984 ( CVO Pizza ) Hello Cmdy, I resubmitted for fire yesterday and the lady I submitted to mentioned that I may get to review the corrections with you over the counter Most items were notes that were initially added but unfortunately the wrong sheets got plotted and re-submitted Please let me know if there is a time I can meet with you regarding these corrections If an over the counter meeting isn't necessary, please let us know when we can expect to get these corrections reviewed Thank you so much, - Josh On Wed, Oct 2, 2013 at 12.09 PM, Cynthia Wong <Cvnthia Wong(g',carlsbadca.gov> wrote Josh, I just review your submittal It has been emailed to Melissa (contact on application) All but two referenced corrections were not found on the plan The occupant load for patio was not calculated correctly Resubmit and either indicate on plans with the corresponding delta or as noted in corrections (bubble all changes ) Thanks you From: Josh Ayer [mailto:iosh(g)studiomyid.com] Sent: Monday, September 30, 2013 2-22 PM To: Cynthia Wong Cc: Janet Altar; Raenette Abbey, Melissa Young Subject: Re CB131984 Hello Cynthia, We resubmitted our plans about 2 weeks ago and we just wanted to get an update on where we were at with the corrections or approval. Thank you. Josh On Thu, Sep 12, 2013 at 8 28 AM, Cynthia Wong <Cvnthia Wong(a),carlsbadca gov> wrote Josh, When you resubmit, please send me an email reminder so I can look for it my plan queue Thank you From: Josh Ayer [mailto-psh^studiomyid com] Sent: Wednesday, September 11, 2013 11.24 AM To: Cynthia Wong Cc: Janet Altar, Raenette Abbey Subject: Re. CB131984 Hello Cynthia, There was some confusion and we were under the impression that we received all of our corrections back and re-submitted We realized when we re-submitted that we were still waiting on corrections from Fire and Engineering We are complete on our Fire corrections and are still waiting on corrections from Engineering We will resubmit our full set once engineering is complete Thank you. Josh On Wed, Sep 11, 2013 at 10 46 AM, Cynthia Wong <Cynthia Wongfojcarlsbadca gov> wrote. Hello, A correction sheet was emailed and sent via USPS on September 4, 2013 The revisions received does not show the corrections as commented by Fire due to dates of corrections in relation to revision set II Please note that correction set III shall address fire comments and will need to be sent to Esqil for review as well Due to the number of comments, slip sheeting will not be an option If you have any questions, please feel free to call me at 760-602-4662 Cindy Wong Carlsbad Fire Josh Ayer Designer StudioMYID 2926 Upas Street San Diego, CA 92104 619 829 8846 joslKSjstudiomvid com www studiomyid com Josh Ayer Designer StudioMYID 2926 Upas Street San Diego, CA 92104 619 829 8846 Raenette Abbey Fronns lentt Tot Cct lubjectt Josh Ayer <josh@studiomyid.com> Wednesday, September 11,201311:24 AM Cynthia Wong Janet Altar; Raenette Abbey Re: CB131984 Hello Cynthia, There was some confusion and we were under the impression that we received all of our corrections back and re-submitted We realized when we re-submitted that we were still waiting on corrections from Fire and Engineering We are complete on our Fire corrections and are still waiting on corrections from Engineering We will resubmit our full set once engineering is complete Thank you, - Josh On Wed, Sep 11, 2013 at 10 46 AM, Cynthia Wong <Cynthia Wong@carlsbadca gov> wrote Hello, A correction sheet was emailed and sent via USPS on September 4, 2013 The revisions received does not show the corrections as commented by Fire due to dates of corrections in relation to revision set II Please note that correction set III shall address fire comments and will need to be sent to Esqil for review as well Due to the number of comments, slip sheeting will not be an option If you have any questions, please feel free to call me at 760-602-4662 Cindy Wong WOOD FIME WOOD SEAL FLAME RETARDAN'TSTVfSDS OCT 09 2013 ENT MSDS (Material Safety Data Sheet) EMERGENCY TELEPHONE NO.: 800-424-9300 PRODUCT NAME Wood ScaF'^ Fire Retardant (No PBDES - Polybrommated diphenyl ethers) CHEMICAL FAMILY Aqueous based fire retardant penetrant/coating SECTION I - PRODUCT INFORMATION MANUFACTURER'S NAME: FLAME SEAL PRODUCTS, INC. 4025 WILLOWBEND BLVD #310 HOUSTON, TX 77025 USA s TELEPHONE # FOR INFORMATION: 713-668-4291 SECTION II - HAZARDOUS COMPONENTS COMPONENT ACGIH OSHA CAS REGISTRY NO WT. % TLV PRL Phosphoric Acid <0 1% 500 ppm TWA 400 ppm TWA 00764-38-2 • 500 ppm STEL 500 ppm STEL SECTION m - PHYSICAL PROPERTIES APPEARANCE AND ODOR Clear, odorless liquid MOLECULAR WEIGHT Not Applicable BOILING POINT (DEGREES FAHRENHEIT) 212 - Not accurate mixture of components MELTING POINT (DEGREES FAHRENHEIT) Not Applicable VAPOR PRESSURE (mm of Mercury) NotDetermmed SPECIFIC GRAVITY (WATER=1) 111-115 RECEIVED OCT 0 9 2013 CITY OF CARLSBAD BUILDING DIVISION /3/flY VAPOR DENSITY (AIR=1) Not Determined PERCENT VOLATILE (BY WEIGHT) 72 0% (water content only) pH 2 0-30 SOLUBILITY IN WATER Complete EVAPORATION RATE (BUTYL ACETATE=1) NotDetermmed SECTION IV - FIRE AND EXPLOSION DATA FLASH POINT (DEGREES FAHRENHEIT PENSKY-MARTENS CLOSED CUP) Nonetoboilmg FIRE EXTINGUISHING MEDIA Not combustible Use water spray, fog, foam, dry chemicals, CO2, or other agents as appropriate for matenal m surrounding fire FLAMMABLE LIMITS (PERCENT BY VOLUME) Not applicable SPECL^L FIRE FIGHTfNG PROCEDURES AND EQUIPMENT Not combustible Use safety equipment and clothmg which is suitable for matenals m surroundmg fire UNUSUAL FIRE AND EXPLOSION HAZARDS May liberate flammable hydrogen gas after long tenn storage of liquid m metal containers Store liquid only m stamless steel, plastic or glass vessels HAZARDOUS COMBUSTION PRODUCTS Combustion products can mclude carbon dioxide, carbon monoxide, oxides of phosphorus and traces of ammonia SECTION V - REACTIVITY DATA STABILITY STABLE X UNSTABLE CONDITIONS TO AVOID Storage of "liquid" in contamers other than plastic, stam-less steel or glass Contammation with strong oxidizers, strong alkali or strong acids INCOMPATIBILITY (MATERL\LS TO AVOID) Strong oxidizers, alkalis, or acids When m liquid state the product slowly reacts with some common metals causing flammable hydrogen gas to be emitted HAZARDOUS DECOMPOSITION PRODUCTS Not applicable HAZARDOUS POLYMERIZATION Will Occur Will Not Occur X SECTION VI - HEALTH HAZARD INFORMATION EXPOSURE FROM ROUTINE USE No evidence of adverse effects from available mformation EFFECTS OF OVEREXPOSURE EYES Direct contact or prolonged exposure to mist may cause redness and pam NOSE Breathmg of heavy concentrations of mists may cause smus irritation and dizzmess MOUTH Ingestion may cause nausea SKIN Prolonged contact may cause reddenmg of effected area PROBABLE ROUTES OF EXPOSURE Skm, eyes, inhalation, and mgestion EMERGENCY AND FIRST AID PROCEDURES EYE CONTACT Immediately flush eyes with water for at least 15 mm mcludmg underneath eyelids Consult a physician if imtation persists INHALATION Remove to fresh air immediately Use adequate ventilation INGESTION Substance exhibits very low toxicity Consult a physician if upset stomach or nausea occur SECTION VII - TOXICITY DATA ORAL Acute Oral Toxicity Ld50 (rat) > 5000 mg/kg DERMAL Not established, not expected to be harmful May be imtatmg with continual contact INHALATION Not established Not expected to be harmful If necessary, use respirator (if adequate ventilation is not available) to keep exposure to particulate matter at a mmimum OTHER PERTINENT DATA Not applicable SECTION Vni - SPECIAL PROTECTION INFORMATION PERSONAL PROTECTION EQUIPMENT PROTECTIVE GLOVES Wear impervious gloves as necessary to avoid excessive skm contact 1 e rubber or neoprene EYE PROTECTION Protective glasses or goggles m heavy mist areas RESPIRATORY PROTECTION (SPECIFY TYPE) For heavy mist exposure use a NIOSH/MSHA approved respirator suitable for use with organic vapors if proper ventilation can not be provided OTHER PROTECTIVE EQUIPMENT Adequate clothmg to mmimize direct contact with skin VENTILATION LOCAL EXHAUST Use exhaust fans if necessary to confrol mist or vapor MECHANICAL (GENERAL) Normal room ventilation of fans SPECL\L Not applicable SECTION IX - SPILL, LEAK, AND DISPOSAL PROCEDURES STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED Confine spilled matenal and absorb on sand, sawdust, earth or other available solids Sweep and place m a suitable container Flush with water and rmse minor spills mto sewer if permitted by Federal, State and local regulations WASTE DISPOSAL METHODS Incmerate or bury m a suitable land fill where permitted by appropnate govemment regulations CLEAN WATER ACT REQUIREMENTS Section 311 of the Clean Water Act lists phosphorus as a hazardous substance which, if discharged mto or upon water, will present an rmmment and substantial danger to public health and welfare Spills of 5000 pounds or more must be reported to the National Response Center @ 1-800-424-8802 RESOURCE CONSERVATION AND RECOVERY ACT (RCRA) REQUIREMENTS No applicable mformation found SECTION X - REGULATORY INFORMATION FDA No apphcable information found USDA No applicable mformation found CPSC No applicable mformation found TSCA No applicable information found DOT No applicable mformation found PROPER SHIPPING NAME Not applicable HAZARDOUS CLASS Not applicable LABEL REQUIRED Not applicable IDENTIFICATION NUMBER Not applicable OTHER PERTINENT INFORMATION Not applicable SECTION XI - SPECIAL PRECAUTIONS AND COMMENTS PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING Keep away from eyes Avoid prolonged contact with skin Wash exposed skm with soap and water Avoid breathmg of mist OTHER PRECAUTIONS Not applicable REGISTRATION/CERTIFICATIONS Not applicable EFFECTIVE DATE: February 4,2005 SUPERSEDES November 20, 2003 This mformation is ftimished without warranty, representation, mducement or license of any kmd, except that it IS accurate to the best of Flame Seal Products, Inc knowledge, or obtamed from sources believed by Flame Seal Products, Inc to be accurate, and Flame Seal Products, Inc does not assume any legal responsibility for use or reliance upon same Customers are encouraged to conduct their own tests Before usmg any product, read its label ' ® Registered m US Patent and Trademark Office ™ Trademark of FLAME SEAL PRODUCTS INC (Non Toxic, Non Hazardous, No PBDEs - Polybrominated diphenyl ethers) ADDRESS: FLAME SEAL PRODUCTS, INC. 4025 Willowbend Blvd # 310, Houston, Texas, 77025 USA, (713) 668' office, (713) 668 1724 fax. Website www flameseal com Email flameseal@flameseal com Intertek Intertek Testing Services NA, Inc. 16015 Shady Falls Road Elmendorf,TX78112 (voice) 210-635-8100 (fax) 210-635-8101 www mtertek- erisemko com ASTM £84-05 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS Report No 3127494SAT-001 Wood Seal - A, Water Based , Liquid intumescent penetrant July 6, 2007 Prepared for Flame Seal Products, Inc 4025 Willowbend Bivd #310 Houston, Texas 77025 Flame Seal Products, Inc. rage i oi y July 6, 2007 ABSTRACT Test Specimeii: Wood Seal - A, Water Based, Liquid intumescent penetrant Test Standard. ASTM 184-05 Test Date. July 05. 2007 Test Sponsor: Flame Seal Products, Inc. Test Results-FLAME SPREAD INDEX SMOKE DEVELOPED INDEX = 25 50 N/A ft. Beyond Burners Centeiline This report is for the exclusive use of Intertelc's Client and is proutciecl pursuant to the agieement between Intertek and its Ghent Intertek's responsibilit-y and liability are limited to the terms and tonditions of the agieement Intertefc assumes no liability to any party, other than to the Client m accordance witii the agreement, for arty loss, expense or damage occasioned by the use of this leport Only the Qient is autlionzed to copy or distiibtite this re|>ort and then only m its entiiety Any use o/the Intertek name or one of its marks for the. sale o) advertisement of the tested matenal, product m service must first he approved in uiritmg by Intertek The observations and test results m this report are reWant only to the sample tested This report by itself does not \mph) that the matenal, fJToduct, or sewice is or has euer been under an Intertek certi/ication fJiogiam. Teodoro Alvarado Ji E84 Operatoi Reviewed and approved. Iulv6.2007 Stephanie Ivrartmez-Didz Teclinical Writer Tulv6. 2007 jcvepori INC. jinf^toiS-i-sjui i'-ige ^ oi y July 6, 2007 Flame Seal Products, Inc. I INTRODUCTION This report describes the results of the ASTM E84-05 Standard Test Method for SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, a method for deteimming tlie comparative surface burnmg behavior of building materials,. This test is applicable to exposed surfaces, such as ceilings or walls, provided that the material oi assembly of materials, by its own structural quality oi the manner in which it is tested and intended for use, is capable of supportmg itself in position or bemg supported durmg tlie test period The purpose of die metliod is to determine tlie relative burning bcliavtor of tlie material by observing the flatne spread along the specimen Flame spread and smoke density developed are reported, however, there is not necessarily a relationship between diese two measurements. "The use of suppoitmg materials on the underside of the test specimen may lower die flame spread index from tliat which imght be obtamed if die specimen could be tested widiout sudi support. Tins method may not be appropriate for obtaining comparative surface burnmg behavioi of some cellular plastic materials. Testing of materials that melt, drip, or dclaminatc to such a degree diat the continuity of the flame fiont is destroyed, results m low flame spread indices that do not relate directly to indices obtained by testing materials that remain in place " This test metliod is also published under the following designations. ANSI 2.5 NFPA 255 UBC 84 (42-1) UL 723 This standard should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the Ure hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Report INO. Jli/4y4SAl-UUl Flame Seal Products, Inc. I'age ol y July 6, 2007 II PURPOSE The ASTM E84-05 (25 foot tunnel) test mediod is intended to compare the surface flame spread and smoke developed measurements to diose obtained from tests of fibei cement board and select grade red oak flooring. The test specimen surface (18 inches wide and 24 feet long) is exposed to a flaming fire exposure during the 10 minute test duration, whde flame spread over its surface and density of the resulting smoke ate measured and recorded. Test results are presented as die computed comparisons to the standard calibration matenals The furnace is considered under calibration when a 10 minute test of red oak decking will pass flame out the end of the tunnel in five minutes, 30 seconds, plus or minus 15 seconds. Fiber cement board forms the zero point for both flame spread and smoke developed indexes, while die red oak flooring smoke developed index is set as 100. Ill DESCRIPTION OF TEST SPECIMEN Specimen Identification Wood Seal - A, Water Based , Liquid intumescent penetrant Date Received: Date Prepared. Conditionmg (73°F &L 50% R.H,): Specimen Widdi (m): Specimen Length (ft)- Specimen Thickness: Material Weight: Total Specimen Weight: Adhesive or coating application rate: 6/29/2007 6/29/2007 6 days 21.75 24 0 7360-in. N/A oz./sq. yd 128.4-lbs. N/A Mounting Methods Ttie specimen was self-supporting and was placed durecdy on die inner ledges of the ainiiel. Specimen Description! Tlie test specimen was described by the client as the "DECK. 1" x 6" x 8-ft. Douglas Fir boards hand picked with wide grain line spacmg. Assembled and affixed to 2 x 4 pme nailers that are spaced @ 24" centers at a 90" angle to die Fir boards. FR- Wood Seal - A spray apphed with Wagner Sprayer; 2 coats @ 300 square feet per gallon eacli, net = 150 square feet per gallon." The specimen consisted of (3) 8-ft. long x 21.75-m. wide x 0 7360-in, thick, brown wood panels. Tlie specimen was identified by the client as "Wood Seal - A, Water Based , Liquid intumescent penetrant" Tlie test specimen was received by our peisonnel m good condition. iveport J.NO. jii/'iy'KSAi-uui rage j oi y ^ , , July 6,2007 Flame Seal Pioducts, Inc. IV TEST PROCEDURE The tests were conducted in accoidance with the procedures outlined in the Amencan Society for Testing and Materials ASTM E84-05. The self- supporting specimens were placed direcdy on the tunnel ledges As requiied by the standard, one or more layers of 0 25 inch duck reinforced concrete board was placed on top of the test sample between the sample and the tunnel hd. After the tests, the samples were removed from the tunnel, examined and disposed of. The test was conducted on 7/5/2007, and not witnessed by any third patties. V TEST RESULTS The test results, computed on the basis of observed flame front advance and electromc smoke density measurements are presented m the followmg table. In recogmtion of possible variations and hmitations of the test method, the results are computed to the nearest number divisible by five, as outlined in the test method for smoke developed mdex results gi-eater than 200 the calculated value is rounded to the nearest 50 points. While no longer a part of this standard test method, the Fuel Contributed Value has been computed, and may be found on the computer printout sheet in the Appendix. E84 (10 Minute) E84 (10 Minute) NFPA 703 (30Minute) Flame Spread Smoke ft Test Specuneii Index Developed Index Fiber Cement Board 0 0 N/A Red Oak Floormg 100 N/A Wood Seal - A, Water Based, Liquid 2.5 50 jqy^ intumescent penetrant The data sheets are included m the Appendix. These sheets are actual print-outs of the computerized data system which monitors the ASTM E84-05 apparatus, and contain all calibration and specimen data needed to calculate the test results. j\eport iNo. Ji^rfyw/VA-uui r.ige u oi y Flame Seal Products, Inc. ^ ^' ^'^^ VI OBSERVATIONS During the test, die specimen was observed to behave in die following manner The wood panels began to char at 0:37 (min:sec.). The wood panels ignited at 1:16 (mm-sec). Tlie test continued for die 10:00 duration After the test burners were turned off, a 60 second afterflame was observed. After the test the specimen was observed to be damaged as follows The wood panels had a intumescent char from 0-ft. - 15-ft. and discolored fiom 15-ft. - 24-ft. Report iNo. Ml /4y4t>Ai-UUl I'age / ot y o I n 1 t July 6,2007 rlame oeal Products, Inc. APPENDIX ASTM E84-05 Data Sheets ASTME84-05 Rage 8 of 9 Client FLAME SEAL PRODUCTS, INC. Date 7/5/2007 Project Number 3127494 Test Number 7 Operator TA/EA Specimen ID. "Wood seal - A intumescent liquid penetrant, Deck: 1" x 6" x 8-ft Douglas Fir boards hand picked with wide gram line spacing Assembled and affixed to 2 x 4 pine nailers that are spaced @ 24" centers at a 90° angle to the Fir boards FR- Wood Seal - A spray applied with Wagner Sprayer; 2 coats @ 300 square feet per gallon each, net =150 square feet per gallon TEST RESULTS FLAME SPREAD INDEX: 25 SMOKE DEVELOPED INDEX: 50 SPECIMEN DATA. . Time to ignition (sec)- 76 Time to Max FS (sec) 549 Maximum FS (feet) 8 5 Time to 980 "F (sec) NEVER REACHED Time to End of Tunnel (sec) NEVER REACHED Max Temperature (F) 672 Time to Max Temperature (sec) 595 Total Fuel Burned (cubic feet) 48.56 FS* Time Area (rmin): 50 8 Smoke Area (%A*min) 58 9 Unrounded FSI 26 2 CALIBRATION DATA . Time to ignition of last Red Oak (sec) 39 Red Oak Smoke Area (%A*m in) 121 Project No 3127494SAT-001 FLAME SPREAD (ft) Page 9 of 9 Smoke (%A) 100.0; .40.0- S50-0 '600 0 Temperature (°F) -2006, -250.0 600.0 Time (sec) ^ PLUMBING, Development Services ELECTRICAL, Building Division <^ CITY OF MECHANICAL leSS Faraday Avenue r-Ani CDAr\ WORKSHEET 76O6022719 L^AKLODAU B-18 wwwcarisbadcagov Project Address: Permit No.: ^ Information provided below refers to work being done on the above mentioned permit only This form must be completed and returned to the Building Division before the permit can be issued. Buildmg Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drams \ 7 New building sewer lme? Ves No K. Number of new roof drains? C> Install/alter water line? , M6 Number of new wetter heaten?. . ..... j Number of new, relocated or replaced gas outlets? j ^ Number of new hose bibs? f Residential Permits: New/expanded service: Number of new amps: Minor Remodel only: Ves No Commercidi/lndustriai: Tenant Improvement: Number of existing amps involved in this project: ^•\P<^ Number of new amps involved in this project: New Construction: Amps per Panel: Single Phase Number of new amperes. Three Phase Number of new ampere5_ Three Phase 480 Number of new amperes_ Number of new furnaces, A/C, or heat pumps? ^ New or relocated duct work? Ves No Number of new fireplaces? o Number of new exhaust fans? 2_ Relocate/install vent? ^^a^t*/^ Number of new exhaust hoods? y Number of new boilers or compressors? Number of HP ^) B-18 Page 1 of 1 Rev 03/09 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / Business Name , , _. . Business Contact . Telephone # Project Address « City State Zip Code - Mailing Address City State Zip Code ^ Plan File# Project Contact ^ i t Telephone # . f -7*0 ) - MMMfc The following questions represent the facility's activities, NOT the specific project description PART I FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION OCCUPANCY CLASSIFICATION Indicate by circling the item, whether your business will use, process, or store any of the following hazardous matenals If any of the items are arcl§d, applicant must contact the Fire Protection Agency with junsdiction pnor to plan submittal Facility's Square Footage (including proposed project) '^l *• 9 Occupancy Rating A"Z. 1 Explosive or Blasting Agents 5 Organic Peroxides 9 Water Reactives 13 Corrosives 2 Compressed Gases 6 Oxidizers 10 Cryogenics 14 Other Health Hazards 3 Flammable/Combustible Liquids 7 Pyrophoncs 11 Highly Toxic or Toxic Materials (lT]!))lone of These 4 Flammable Solids 8 Unstable Reactives 12 Radioactives PART II SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD) If the answer to anv of the questions is yes, applicant must contact the County of San Diego Hazardous Matenals Division, 5500 Overland Ave , Suite 110, San Diego, CA 92123 Call (858) 505-6700 pnor to the issuance of a building permit FEES ARE REQUIRED YES • • • • • • • NO Project Completion Date / / Expected Date of Occupancy / / 0 • CalARP Exempt I Date Initials • CalARP Required / Date Initials • CalARP Complete I Date Initials (fbr new construction or remodeling projects) Is your business listed on the reverse side of this form' (check all that apply) Will your business dispose of Hazardous Substances or Medical Waste in any amounf Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or caranogens/reproductive toxins in any quantity' Will your business use an existing or install an underground storage tank' Will your business store or handle Regulated Substances (CalARP)' Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)' Will your business store petroleum in tanks or containers at your facility with a total storage capaaty equal to or greater than 1,320 gallons' (California's Aboveground Petroleum Storage Act) PART III SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control Distnct (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 pnor to the issuance of a building or demolition permit Note if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days pnor to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less Contact the APCD for more information YES NO 1 • SL Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant' (See the APCD factsheet at htto /A>ww sdapcd ora/info/facts/oermits pdf, and the list of typical equipment requinng an APCD permit on the reverse side of this from Contact APCD if you have any questions) 2 • • (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject faality be located within 1,000 feet of the outer boundary of a school (K through 12)' (Search the California School Directory at http //www cde ca oov/re/sd/ for public and pnvate schools or contact the appropnate school distnct) 3 • &~ Has a survey been performed to detemiine the presence of Asbestos Containing Matenals' 4 • 01 Will there be renovation that involves handling of any friable asbestos matenals, or disturbing any material that contains non-fnable asbestos' 5 • \0 Will there be demolition involving the removal of a load supporting structural member' Bnefly descnbe business activities I declare under penalty of peijury that to the best of my knowledge and be)i€f the responses r Name of Owner or Authonzed Agent Bnefly descnbe proposed project M t> K f I'VJ 6 F^^^T^'^ ade herein are true and correct Signatoe of Owner or Authorized /Vgent FIRE DEPARTMENT OCCUPANCY CLASSIFICATION . BY Date FOR OFFICIAL USE ONLY DATE EXEMPT OR NO FURTHER INFORMATION REQUIREO RELEASER FOR BUILOING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD HM-9171 (02/11) County of San Diego - DEH - Hazardous Matenals Division INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY Date_ilLi:lI Business Name 6H0 'piZl-A' Street Address ?f^l<M^A^ Mf-?0^ Email Address T5c>^i\^ <:;t-'0\ON^^ l\P • CC^/VA PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility Acid Cleaning Ink Manufactunng Nutritional Supplement/ Assembly Laboratory Vitamin Manufactunng Automotive Repair Machining/Milling Painting / Finishing Battery Manufacturing Manufactunng Paint Manufactunng Biofuel Manufactunng Membrane Manufacturing Personal Care Products Biotech Laboratory (i e water filter membranes) Manufactunng Bulk Chemical Storage Metal Casting / Forming Pesticide Manufactunng / Car Wash Metal Fabncation Packaging Chemical Manufactunng Metal Finishing Pharmaceutical Manufactunng Chemical Purification Electroplating (including precursors) Dry Cleaning Electroiess plating Porcelain Enameling Electncal Component Anodizing Power Generation Manufactunng Coating (i e phosphating) Print Shop Fertilizer Manufactunng Chemical Etching / Milling Research and Development Film / X-ray Processing Printed Circuit Board Rubber Manufactunng Food Processing Manufactunng Semiconductor Manufactunng Glass Manufactunng Metal Powders Forming Soap / Detergent Manufactunng Industnal Laundry Waste Treatment / Storage SIC Code(s) (if known) Brief descnption of business activities (Production / Manufactunng Operations) Description of operations generating wastewater (discharged to sewer, hauled or evaporated) Estimated volume of industnal wastewater to be discharged (gal / day) List hazardous wastes generated (type/volume) Date operation began/or will begin at this location Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority'^ Yes No ^If yes, when Site Contact Signature_ Title Phone No ENCINA WASTEW^R AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760)438-3941 F/0< (760)476-9852 CB131984 2519 PALOMAR AIRPORT RD 101 (9iik^vr-^i^^^(- ^^^^ ^/|3fe CA-t-tOreF^/v^ <(f 1^ - 5(irS^ Final Inspection required by • Plan • CM&I • Fire Approved / Date By BUILDING 7^/ I& PLANNING ENGINEERING FIRE Expedite? Y CJV AFS Checked by HazMat APCD Health Forms/Fees sent Reed Due' By Encina Y N Fire Y N / HazHealthAPCD Y N / PE&M s / Y N School Y N Sewer Y N Stormwater Y N Special Inspection Y N CFD Y N LandUse Density ImpArea FY Annex Factor PFF I^Y/ N Comfn^ntS Date Date Date Date Building ^||^||3 Planning Engineering — Fire Need? , ' ' ' Q Done • Done 10-30-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR13147 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # PC# Project Title 2519 PALOMAR AIRPORT RD CBAD St 101 PCR 2130201800 Lot# 0 $0 00 Construction Type 5B CB131984 CYO PIZZA- REVISED PLANS TO REMOVE PATIO DINING AREA & CHANGE WOOD FINISHES Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 10/17/2013 RMA 10/30/2013 10/30/2013 Applicant JOSH AYER Owner COUNTY OF SAN DIEGO 2926 UPAS ST SAN DIEGO CA 92104 619 829-8846 PUBLIC AGENCY 00000 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees $107 50 $0 00 $0 00 Total Fees $107 50 Total Payments To Date $107 50 Balance Due $0 00 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes ttie "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required mformation with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenwise expired A PLAN CHECK REVISION Development Services Building Division 1635 Faraday Avenue c, ^ CITY OF APPLICATION Development Services Building Division 1635 Faraday Avenue c, MLSBAD B-15 760-602-2719 www carlsbadca gov Plan Check Revision No. Project Address K^A^ 4^ .Original Plan Check No . Date. Fax Contact 30^W A^^tl Ph (^j^'^Z^-^M^ Email '5"0^i-t(^ <^KJ^\0\^^\V .CO^ Contact Address O^f^ General Scope of Work C^TAV^^A 'T- \. City ^'^-N Pifi^o Zip Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person 1 • Elements revised [2\ Plans • Calculations • Soils • Energy • Other. 2. Describe revisions in detail 3. List page(s) where each revision is shown 4. List revised sheets that replace existing sheets 5 • Does this revision, in any way, alter the exterior of the project? ^0. Yes 6. Does this revision add ANY new floor area(s)7 • Yes |^No 7. Does this revision affect any fire related issues? Yes • No 8. Is this a complej^et"?! Yes • No ^Signature —J----'*''^'''''^^. ./\. • No 1635 Faraday Avenue, Carlsbad. CA 92008 Eh 760-602- 2719 Eax 760-602-8558 Email building@carlsbadca gov wwwcarisbadcagov EsGil Corporation In (Partnership with government for (BuiCding Safety DATE 10/28/2013 • APPLICANT ^ JURIS JURISDICTION City of Carlsbad XI PLAN REVIEWER • FILE PLAN CHECK NO 13-1984(pcrl3-147) SET I PROJECT ADDRESS 2519 Palomar Airport Rd., Ste. 5-101 PROJECT NAME Cyo Pizza T. I. XI The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to 1X1 EsGil Corporation staff did not advise the applicant that the plan check has been completed I I EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Email Fax # Mail Telephone Fax In Person • REMARKS By Aaron Goodman Enclosures EsGil Corporation • GA • EJ • PC 10/21/2013 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 13-1984(pcrl3-147) 10/28/2013 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 13-1984(pcrl3-147) PREPARED BY Aaron Goodman DATE 10/28/2013 BUILDING ADDRESS 2519 Palomar Airport Rd., Ste. 5-101 Set I BUILDING OCCUPANCY A TYPE OF CONSTRUCTION V-B Sprinklered BUILDING PORTION AREA (Sq Ft) Valuation Multiplier Reg Mod VALUE ($) T 1 Rev Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review I I Repetitive Fee Repeats • Complete Review • Other • Hourly EsGil Fee $107 50 • Structural Only 1 $86 00 Hr. @ * $86.00 Based on hourly rate Comments Sheet 1 of 1 macvalue doc + 4J ^ CiTY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www carlsbadca eov DATE: 10/22/13 PROJECT NAME: T.I. REVISIONS PROJECT ID: PLAN CHECK NO: PCR13147 SET#: ADDRESS: 2519 PALOIVIAR AIRPORT RD APN: XI This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required • Yes ^ No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. Q This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: josh@studiomyid.com For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665- 1 1 Chris Sexton 760-602-4624 Chris Sexton@carlsbadca ^ov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov Q Greg Ryan 760-602-4663 Gregorv Rvan@carlsbadca gov j 1 Gma Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov Q Cindy Wong 760-602-4662 Cvnthia WongOcarlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca gov Remarks- Roof mounted equipment stated on plans that they will not be higher than parapet. This Planning approval will be null and void if equipment is visible. Per project Planner, ok to remove the outdoor seating from this plancheck. ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov 4^ DATE: 10/23/13 PROJECT NAIVIE: cyo pizza PROJECT ID PLAN CHECK NO: pcrl3147 (cbl31984) SET#: l(slip slieet) ADDRESS: 2519 PA'R^ APN: This plan check review is complete and has been APPROVED by the firQ^ision. By: cwong A Final Inspection by the Division is required |^ Yes • No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: IVIelissa@studiomyid.com (and via usps) you may aiso have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked- PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 Chris Sexton 760-602-4624 Chns Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 1 Greg Ryan 760-602-4663 Gregory Rvan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov X Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca gov Remarks. 10/23/13 **APPROVED: Page 1 of 4 THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. 10/20/13 *** Josh or representative from Studio My ID to schedule and OTC with C Wong to red line the following (call 760-602-4662 or email to schedule) These are in response to the responses from Studio My ID received October 17, 2013.: 1. Comment #1 - Current codes on I-l.O: Did not add Calfornia Fire Code to list of applicable codes. 2. Comment #5: In reference to note #7 on sheet 1-2.1: this is not verbatim as stated in section 1008.1.9.3 of CBC and CFC, 2010 edition. The word "mam" has been omitted. This interpretation now could mean all extenor doors and not "mam". Revise. 3 Comment #6. Reference #5 above. Not both doors need to be equipped with panic type hardware. "Main" exterior door or doors (if double-leafed) maybe if requirements of #2 of section 1008.19 3 are met. 4. Comment #9: There is not delta 3 on sheet E2 as stated. Please clanfy. CO from CB131984 10/2/13 ***Bubble All Changes*** The majonty of corrections were not addressed in Fire Set III. A copy of corrections accompanied the resubmittal with comments in red for corrections. The comments or corrections stated as made were not found on Fire Set III. Please see results below: 1. Sheet 1-1.0 State current codes this project references for design and construction **NOT FOUND ON 4/1-1.0** 2. Sheet 1-1.0- Occupant load not given/N/A for outdoor seating area. However the outdoor seating area is 50. If enclosed, the patio shall have an occupant load calculation as if it were interior. Recalculate. Indicate fixed or non- fixed seating in calculations. **PLEASE JUSTIFY FROM CFC TABLE 1004 1 OCCUP LOAD FACTOR OF 50 USED. THIS SHOULD BE 15. RECALCULATE UNLESS THIS IS A LAB, GYMNASIUM, LIBRARY OR SIMILAR. 3. Sheet 1-20: Mechanical Notes: Add the following or similar: Air moving systems supplying air in excess of 2000 cubic feet/mmute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC section 608 and NFPA 72. **THERE IS NO #9 ON MECHANICAL 1-2.0 Page 2 of 4 4. Sheet 1-2.1: Add the following or similar: "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic spnnklers and wet and dry standpipes; inert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation. (CFC 901.2)" ** THERE IS NO #29 ON ENTIRE SHEET 1-2.1** 5. Sheet 1-2.1: Fire Notes: We are currently in the CBC and CFC, 2010 edition, NOT UBC. Please update references made to the UBC (#7,10,16,18, etc.) to reflect correct and current code in CBC or CFC. **ALL NOTES REFERENCED ABOVE WERE NOT REVISED** 6. Sheet 1-4 0- Specify door hardware for door 102. **IT IS NOTED THAT BOTH FRONT AND BACK DOOR HAVE THE SAME HARDWARE. ARE BOTH DOUBLE KEY LOCKED WITH SIGN ABOVE?** 7. Sheet 1-9.1. Provide manufacturer's cut sheet for wood panels. **CONFIRM THAT THESE WOOD PANELS ARE FLOOR FINISH. IF INTERIOR FINISH, PROVIDE CUT SHEETS THAT SHOW COMPLIANCE WITH CBC 803.9 FOR FLAME INDEX** 8 Sheet H: Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department. If this is needed for reference, please state so and it may remain. **COMPLETE** 9. Sheet E2 and 1-7.0: The following requirement for emergency lighting shall be met. Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge. The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress Illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed m accordance with CFC 1011. Indicate on reflective ceiling AND electncal sheets. **ONLY NOTES ADDED - NO CHANGE ON PLAN - ADD REQUIRED EM LIGHTS OR SUBMIT A PHOTOMETRIC PLAN FOR JUSTIFICATION** 10. Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code **NOTDONE** 9/4/2013 *** Bubble All Changes *** *** Bubble all Changes *** 1. Sheet 1-1.0 State current codes this project references for design and construction. 2. Sheet 1-10: Occupant load not given/N/A for outdoor seating area. However the outdoor seating area is 50. If enclosed, the patio shall have an occupant load calculation as if it were intenor. Recalculate. Indicate fixed or non- fixed seating in calculations. Page 3 of 4 3. Sheet 1-20: Mechanical Notes: Add the following or similar: Air moving systems supplying air in excess of 2000 cubic feet/mmute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required. CMC section 608 and NFPA 72. 4 Sheet 1-2 1: Add the following or similar: "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic spnnklers and wet and dry standpipes; inert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation. (CFC 9012)" 5. Sheet 1-2.1: Fire Notes: We are currently in the CBC and CFC, 2010 edition, NOT UBC. Please update references made to the UBC (#7,10,16,18, etc.) to reflect correct and current code in CBC or CFC. 6. Sheet 1-4.0: Specify door hardware for door 102. 7. Sheet 1-9.1: Provide manufacturer's cut sheet for wood panels. 8. Sheet H: Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department. If this is needed for reference, please state so and it may remain. 9. Sheet E2 and 1-7.0: The following requirement for emergency lighting shall be met. Furniture placement shall be considered In the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress Illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011. Indicate on reflective ceiling AND electrical sheets. 10. Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, m accordance with the Business and Professions Code. Page 4 of 4 Carlsbad Fire Department Plan Review Requirements Category PCR Date of Report 10-23-2013 Name Address Permit #:PCR13147 JOSH AYER 2926 UPAS ST SAN DIEGO CA 92104 Reviewed by: Job Name. CYO PIZZA- REVISED PLANS TO Job Address- 2519 PALOMAR AIRPORT RD CBAD St 101 ml ,llMi'frW-Fpiii.iiiT1ii iiiii III ^ou-hayt;^ siibmitted for review is incomplete At this time, this office cannot adequately conduct a review todeterm|ga£ei^^ Please review carefully all comments aSaefe^*Tlease resubmit the necessary plans^^^psggggifications, with changes "clouded", to this office fo*«rt^^ewand approval. Conditions: Cond: CON0006720 [NOT MET] *** Josh to schedule and OTC with C Wong to red line the following (call 760-602-4662 or email to schedule) These are in response to the responses from Studio My ID received October 17, 2013 1. Comment #1 Current codes on I-l .0. Did not add Calfornia Fire Code to list of applicable codes 2. Comment #5. In reference to note #7 on sheet 1-2.1 - this is not verbatim as stated in section 1008.1 9.3 of CBC and CFC, 2010 edition The word "mam" has been omitted This interpretation now could mean all exterior doors and not "main" Revise. 3 Comment #6 Reference #5 above Not both doors need to be equipped with panic type hardware. "Main" extenor door or doors (if double-leafed) maybe if requirments of #2 of section 1008'. 1 9 3 are met 4 Comment #9 There is not delta 3 on sheet E2 as stated. Please clarify Entry- 10/20/2013 By cwong Action- CO Cond. CON0006728 [MET] ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry 10/23/2013 By: cwong Action AP m CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 10/20/13 PROJECT NAIVIE: cyo pizza PLAN CHECK NO: pcrl3147 (cbl31984) SET#: I PROJECT ID: ADDRESS: 2519 PAR APN: Q This plan check review is complete and has been APPROVED by the fire Division. By: cwong A Final Inspection by the Division is required |^ Yes • No ^ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: Melissa@studiomyid.com (and via usps) You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clanfications on the attached checklist please contact the followmg reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chns Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov Q Greg Ryan 760-602-4663 Grefiorv Rvan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov X Cindy Wong 760-602-4662 Cynthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca.gov Remarks: 10/20/13 Page 1 of 4 *** Josh or representative from Studio My ID to schedule and OTC with C Wong to red line the following. (call 760-602-4662 or email to schedule) These are in response to the responses from Studio My ID received October 17, 2013. 1 Comment #1. Current codes on I-l 0' Did not add Calfornia Fire Code to list of applicable codes. 2. Comment #5: In reference to note #7 on sheet 1-2 1- this is not verbatim as stated in section 1008.19.3 of CBC and CFC, 2010 edition. The word "mam" has been omitted. This interpretation now could mean all extenor doors and not "mam". Revise. 3 Comment #6 Reference #5 above. Not both doors need to be equipped with panic type hardware. "Mam" exterior door or doors (if double-leafed) maybe if requirements of #2 of section 1008.1.9.3 are met. 4. Comment #9: There is not delta 3 on sheet E2 as stated. Please clarify. CO from CB131984 10/2/13 ***Bubble All Changes*** The majonty of corrections were not addressed in Fire Set III. A copy of corrections accompanied the resubmittal with comments in red for corrections. The comments or corrections stated as made were not found on Fire Set III. Please see results below: 1 Sheet 1-10 State current codes this project references for design and construction **NOT FOUND ON 4/1-1.0** 2 Sheet 1-1.0: Occupant load not given/N/A for outdoor seating area. However the outdoor seating area is 50 If enclosed, the patio shall have an occupant load calculation as if it were interior. Recalculate. Indicate fixed or non- fixed seating in calculations. **PLEASE JUSTIFY FROM CFC TABLE 1004.1. OCCUP LOAD FACTOR OF 50 USED. THIS SHOULD BE 15. RECALCULATE UNLESS THIS IS A LAB, GYMNASIUM, LIBRARY OR SIMILAR. 3. Sheet 1-20* Mechanical Notes- Add the following or similar- Air moving systems supplying air in excess of 2000 cubic feet/minute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required CMC section 608 and NFPA 72. **THERE IS NO #9 ON MECHANICAL 1-2.0 4. Sheet 1-2.1: Add the following or similar: "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic spnnklers and wet and dry standpipes; mert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation. (CFC 901.2)" ** THERE IS NO #29 ON ENTIRE SHEET 1-2.1** 5. Sheet 1-2.1: Fire Notes: We are currently in the CBC and CFC, 2010 edition, NOT UBC. Please update references made to the UBC (#7,10,16,18, etc.) to reflect correct and current code in CBC or CFC. **ALL NOTES REFERENCED ABOVE WERE NOT REVISED** 6. Sheet 1-4.0: Specify door hardware for door 102. **IT IS NOTED THAT BOTH FRONT AND BACK DOOR HAVE THE SAME HARDWARE. ARE BOTH DOUBLE KEY LOCKED WITH SIGN ABOVE?** 7 Sheet 1-9.1: Provide manufacturer's cut sheet for wood panels. Page 2 of 4 **CONFIRM THAT THESE WOOD PANELS ARE FLOOR FINISH. IF INTERIOR FINISH, PROVIDE CUT SHEETS THAT SHOW COMPLIANCE WITH CBC 803.9 FOR FLAME INDEX** 8. Sheet H: Remove all references to ansul system This shall be a deferred submittal directly to the Carlsbad Fire Department If this is needed for reference, please state so and it may remain. **COMPLETE** 9. Sheet E2 and 1-7.0: The following requirement for emergency lighting shall be met Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below withm the exit access, exit and exit discharge. The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011. Indicate on reflective ceiling AND electrical sheets. **ONLY NOTES ADDED - NO CHANGE ON PLAN - ADD REQUIRED EM LIGHTS OR SUBMIT A PHOTOMETRIC PLAN FOR JUSTIFICATION** 10. Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code. **NOTDONE** 9/4/2013 *** Bubble All Changes *** *** Bubble all Changes *** 1 Sheet 1-1.0 State current codes this project references for design and construction. 2. Sheet 1-1.0. Occupant load not given/N/A for outdoor seating area However the outdoor seating area is 50. If enclosed, the patio shall have an occupant load calculation as if it were intenor. Recalculate. Indicate fixed or non- fixed seating m calculations 3. Sheet 1-20: Mechanical Notes- Add the following or similar. Air moving systems supplying air m excess of 2000 cubic feet/mmute shall be equipped with smoke duct detectors and be tied in to the building fire alarm system. If no fire alarm is present, then an audible, local alarm shall be required CMC section 608 and NFPA 72. 4. Sheet 1-2.1: Add the following or similar- "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic spnnklers and wet and dry standpipes; mert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation. (CFC 901.2)" 5. Sheet 1-2.1. Fire Notes: We are currently in the CBC and CFC, 2010 edition, NOT UBC. Please update references made to the UBC (#7,10,16,18, etc.) to reflect correct and current code in CBC or CFC. 6. Sheet 1-4.0: Specify door hardware for door 102. Page 3 of 4 7. Sheet 1-9.1: Provide manufacturer's cut sheet for wood panels. 8. Sheet H: Remove all references to ansul system. This shall be a deferred submittal directly to the Carlsbad Fire Department If this is needed for reference, please state so and it may remain. 9 Sheet E2 and 1-7.0: The following requirement for emergency lighting shall be met. Furniture placement shall be considered in the placement of EM lighting and shall meet the requirements below within the exit access, exit and exit discharge. The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Illuminated exit signs and egress lighting shall be placed in accordance with CFC 1011. Indicate on reflective ceiling AND electrical sheets. 10 Each sheet of the plan check set (new sheets) must be signed by the person responsible for their preparation, in accordance with the Business and Professions Code. Page 4 of 4 Carlsbad Fire Department Plan Review Requirements Category PCR , Date of Report-10-20-2013 Reviewed by Name JOSH AYER Address- 2926 UPAS ST SAN DIEGO CA 92104 Permit # PCR13147 Job Name CYO PIZZA- REVISED PLANS TO Job Address 2519 PALOMAR AIRPORT RD CBAD St. 101 INCOMPLETE TRrttairytm4mve-subimJds4i^^ is incomplete At this time, this office cannot adequately conduct a review to determine complianceviatKTK§°^ypHeafe-le,,Sgde^ standards Please review carefully all comments attached Please resubmit the necessary plans and/orspe&ftcatiefl,g^ith changes "clouded", to thiS-otii£fijer reviewmid-approval'*'^ Conditions: Cond: CON0006720 [NOT MET] *** Josh to schedule and OTC with C Wong to red line the following (call 760-602-4662 or email to schedule) These are in response to the responses from Studio My ID received October 17, 2013 : 1. Comment #1 • Current codes on I-l .0 Did not add Calfornia Fire Code to list of applicable codes 2 Comment #5 In reference to note #7 on sheet 1-2.1 this is not verbatim as stated in section 1008 1.9 3 of CBC and CFC, 2010 edition The word "main" has been omitted This interpretation now could mean all exterior doors and not "main" Revise 3 Comment #6 Reference #5 above. Not both doors need to be equipped with panic type hardware. "Main" exterior door or doors (if double-leafed) maybe if requirments of #2 of section 1008.1 9 3 are met. 4. Comment #9- There is not deha 3 on sheet E2 as stated Please clarify Entry 10/20/2013 By cwong Action CO INTERIOR ARCHITECTURE & DESIGN Correction Response Letter #2 Project Nutmber: cbl31984 CYO Pizza Fire Division Cindy, In order to limit delays actiieving the permit, the patio area has been removed from the plans and will be a deferred submittal as noted on the cover page The charred wood paneling is also removed from plan and IS being replaced with painted drywall (P3) until more documentation is gathered regarding the specification of the wood paneling and fire retardant sealant Below are our responses to the second set of corrections 1 Current codes can be found on 4/ I-l 0 (bubbled) 2 Exterior Patio is now going to be a deferred submittal and has been removed from all plans 3 See #9 on Mechanical 1-2 0 4 See #25 Fire Department notes 1-2 1 5 See if 7,10,16,18 Under Fire Department Notes 1-2 1 6. Both doors will be equipped with new panic hardware, not double key locked See 1-4 0 7 This product has been removed as to not cause further delays WPl will be replaced with P3 painted drywall Please refer to 1-9 0 and 1-9 1 as well as the elevation sheets 1-12 0 - 1-12 2 for notes calling out the change Documentation will be gathered in the coming weeks regarding WPl ( wood panels) for a deferred submittal 9 See Note 24 @ 1-7 0 and Sheet E2 10 Each revised sheet has designers signature 2926 Upas St, San Diego, CA 92104 Carlsbad Fire Department Plan Review Requirements Category PCR , Date of Report 10-23-2013 Reviewed by Name JOSH AYER Address 2926 UPAS ST SAN DIEGO CA 92104 Permit # PCR13147 Job Name CYO PIZZA- REVISED PLANS TO Job Address 2519 PALOMAR AIRPORT RD CBAD St 101 INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards Please review carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval Conditions: Cond CON0006720 [NOT MET] *** Josh to schedule and OTC with C Wong to red line the following ( call 760-602-4662 or email to schedule) These are m response to the responses from Studio My ID received October 17, 2013 1 Comment #1 Current codes on I-l 0 Did not add Calfornia Fire Code to list of applicable codes 2 Comment #5. In reference to note #7 on sheet 1-2 1 this is not verbatim as stated in section 1008.1 9 3 of CBC and CFC, 2010 edition The word "main" has been omitted This interpretation now could mean all exterior doors and not "main" Revise 3 Comment #6 Reference #5 above Not both doors need to be equipped with panic type hardware "Main" exterior door or doors ( if double-leafed) maybe if requirments of #2 of section 1008 1 9 3 are met 4 Comment #9 There is not delta 3 on sheet E2 as stated. Please clarify Entry. 10/20/2013 By cwong Action CO PCR13147 2519 PALOMAR AIRPORT RD J ijAt /5/^3//3' fiPfrol/ifi- ^S}ii^^ Sl,-^ ^^id ^ Sk^ 't^'S ^or- Sss.!. assess -^CwJ Final Inspection required by • Plan • CM&I • Fire SW GissuED Dev. Approved Date , By BUILDING PLANNING Git. ENGINEERING FIRE Expedite? Y/5?/j,^^^ AFS Checked by ^ HazMat APCD Health Forms/Fees Sent Reed Due' By Encina Y N Fire Y N HazHealthAPCD Y N PE&M Y N School Y N Sewer Y N Stormwater Y N Special Inspection Y N CFD Y N LandUse Density ImpArea FY Annex Factor PFF Y N Comments Oate Date Date Date Building Planning Engineenng Fire Need? • Done • Done • Done • Done 02-14-2014 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR13165 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # PC# Project Title 2519 PALOMAR AIRPORT RD CBAD PCR 2130201800 Lot# $0 00 Construction Type CB131984 CYO PIZZA- REVISE 2 WINDOWS 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 12/20/2013 RMA 12/23/2013 12/23/2013 Applicant MELISSA YOUNG Owner COUNTY OF SAN DIEGO 2926 UPAS ST SAN DIEGO CA 92104 760 519-4446 PUBLIC AGENCY 00000 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees $0 00 $0 00 $0 00 Total Fees $0 00 Total Payments To Date $0 00 Balance Due $0 00 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired Development Services Building Division 1635 Faraday Avenue CITY OF PLAN CHECK REVISION APPLICATION Development Services Building Division 1635 Faraday Avenue CARLSBAD B-15 -V. 760-602-2719 www carlsbadca gov Plan Check Revision No Project Address Original Plan Check No p^( (9 mar Contact 5^ VoU^nO^ PhlU^-Sl^-^^ Fax Email mdI'^f^^.Skn^Xto my/^JP, Cor^ City Contact Address General Scope of Work 1/^ Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 • Elements revised 2. Descnbe revisions in detail 3. List page(s) where each revision is shown 4. List revised sheets that replace existing sheets /- t-Lo 1 -lO.o l-/0,O iK l-IZ. l/l l-IZ.f^/ ' ' 1 5. Does this revision, in any way, alter the extenor of the project? • Yes |^^l 6. Does this revision add ANY new floor area(s)? Q Yes No T. Does this revision affect any fire related issues? • Yes No 8. Is this a comp^te^et? O Yes ^^No .gS'Signatur No comp^te^et? • Yes ^^No 1635 Faraday Avenue, Carlsbad, CA 92008 Ph 760-602- 2719 Fax 760-602-8558 Email building@carlsbadca gov www carlsbadca gov PCR13165 2519 PALOMAR AIRPORT RD kia-jii} /cx~ ^ wii/iJc^ywuii^/leifiit^^ okfiA k)jf jH^i ^ M-J^ Final Inspection required by • Plan • CM&I • Fire • ' sw QlSSUED UCV. Approved Oate By BUILDING PLANNING ENGINEERING FIRE Expedite? Y N AFS Checked by HazMat APCD Health Forms/Fees sent Reed Due? By Enona Y N Fire Y N HazHealthAPCD Y N PE&M Y N School Y N Sewer Y N Stormwater Y N Special Inspection Y N CFD Y N LandUse Density ImpArea FY Annex Factor PFF Y N Comments Date Date Date Date Building Planning Engineering Fire • Done • Done