Loading...
HomeMy WebLinkAbout252 JUNIPER AVE; A1; CB081962; Permit\ City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 10-21-2008 Residential Permit Permit No: CB081962 Building Inspection Request Line (760) 602-2725 Job Address: 252 JUNIPER AV CBAD St: A1 Permit Type: RESDNTL Sub Type: RAD Status: 204240551~ Lot#: 0 Applied: Parcel No: Valuation: $2,500.00 Construction Type: 5B Entered By: Reference #: Plan Approved: Occupancy Group: # Dwelling Units: 0 Structure Type: Issued: Bedrooms: 0 Bathrooms: 0 Inspect Area: Project Tille: SHERMAN: RE-INSTALL BATHROOM Orig PC#: REMOVED ILLEGALLY/ NEW LIGHTING IN KITCHEN/ REPAIR Plar, Check#: Applicant: MOFFAT DAVID STE 142 4660 N RIVER ROAD OCEANSIDE CA 92057 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee J HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee $54.11 $0.00 $35.17 $0.00 $0.00 $1.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 LANSio.oo .:-,;tf\G£ $0.00 $0.00 · -1,FD $0.00 , -.l,• i ,, $0.00 $0.00 $0.00 $0.00 Owner: JOSEPH HARRY R 252 JUNIPER AVE #B01 CARLSBAD CA 92008 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES ISSUED 10/21/2008 JMA 10/21/2008 10/21/2008 Total Fees: $90.28 Total Payments To Date: $90.28 Balance Due: Inspector: yll\. /.o!k-: Date: O Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $90.28 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations; or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fee!<iexactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other requirea information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure wHI bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any f I Tl i ii r h" h fr i h i / City of Carlsbad 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax: 760-602-8558 www.carlsbadca.gov Building Permit Application OB ADDRESS isi-ve. Plan Check No.C BO f? l q ~ 2 Est. Value Plan Ck. Deposit Date I D /-z t / 0 g SUITE#4CE#/UNIT# APN CT/PROJECT# PHASE# # OF UNITS # BEDROOMS # BATHROO S TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP DESCRIPTION OF WORK: Include Square Feet o_f Affected Area(s) ,- /OtJ AMi-J EXISTING USE PROPOSED USE FIRE SPRINKLERS YES O NOD CONTACT NAME (If Different Fom .App/leant) APPLICANT NAME ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL P,ROPERTY OWNER NAME s NTRAcToR eus. NAME /. tJf v/d ADDRESS AD~Rj~ 't b to /\J. 1-tre~ CITY ZIP c 1t'c -et1n s 1 'de_ STATErA ZIP rzos PHONE FAX PHONE 7GO FAX 7C, 6 Z">I -C.3 EMAIL COK . ,,U6-T ARCH/DESIGNER NAME & ADDRESS STATE LIC. # Cl.ASS{? CITY BUS. LIC.# /22-~ flee. 703 I.I Busin,11 and Profe11ions Code: Any City or County which requires a permit to construct. alterf imprm, d•molish or reP,air any structure, prior to iu i11uance. also requires the a_pplicant for such permit to fil• a sicned statement that he is ficensed J)ursuant to the provisions of th• Contractors Licens• uw {Chapter 9, commending with Section 000 of Division 3 of th• Business and Promsions Cod•} or that he is mmpt therefrom. and the basn for the alltged mmption. Any violation of Section 7031.S by any applicant for a permit subjecu tht applicant to a civil penalty of not mon than fivt hundred doHars {$500}). , WORKERS ' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penally of perjury one of the following declarations: D I have and will ·maintain a certttlcate of consent to sett-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy ---.. number are: Insurance Co. ____________________ Policy No. ______________ Expiration Date _________ _ ~ion need not be completed ii the permit is for one hundred dollars ($100) or less . .,e:J Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addttlon to the cost of compensation, dam s pro lded lo lion ~ode, Interest and attorney's lees. ~ CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's License Law /or the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. 11, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section ____ ,Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have / have not) signed an application for a building permit lor the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supelvise and provide the major work (include name I address I phone / contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address I phone/ type of work): ~ PROPERTY OWNER SIGNATURE DATE ~~~~WW.'!£.Q'<-,/~~t:..~ P" ffl'=-~~$t"'«'~ttJ4~(w~~l'W'ffir'':'.:fi~qi",1 'l-f1fc~;t,;r, '. rn r~li';•,c;'\"'-,vJ,...,!l't«f':l'}",,}~\(.~"t't~71T~:;::»ftt~~~'.:J:~Ml ,,t;;; i@W4!'"» "',"Z'\"5.rt"'i '""" • 'f"1Z,"'r<'"¢\"¥1 ~~?f r,c ;oMP,l!ET~E 1,;T,H ,IS ,SE,C,T,IOIN F<F,OR .,N :ON-.RESIDENT,IAL"•~BUIL'DING'PERMITS 'O'NL'V ' ''. ', ' ... ~r-,.. .... 't:1;.1cf,... '" '4:S,. " X "'f,-;~,~o,. ...t:'",. ;...~ 'i)'. ~.1r "", ". ✓ t,.::r ·~·•k ... ~»· Yo,' ~ ' .. ~ ' ~ '" ,. Is the applicant or future building occupant required lo submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 ol the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT, I certify that I have read the application and state that the above information Is correct and that the Information on the plans Is accurate. I agree to comply With all City Ofdinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN Am WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permtt is required for excavations over 5'0' deep and demofrt.ion or construction of structures over 3 stories in height. EXPIRATION: Every permtt issued by the Building Official under the provisions of this Code shall expire by limitation and become nuH and void ff the building or work authorized by such permtt is not commenced within 180 days from the date of such permtt or ff the buildi authorized by such pe or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unfform Building Code). DATE Iv' m • . City of Carlsbad Bldg Inspection Request For: 03/19/2009 . - Permit# CB081962 Inspector Assignment: MC --- Title: SHERMAN: RE-INSTALL BATHROOM Description: REMOVED ILLEGALLY/ NEW LIGHTING IN KITCHEN/ REPAIR WALL IN KITCHEN/ REPLACE 100 AMP Type: RESDNTL Sub Type: RAD Phone: 7609458208 Job Address: 252 JUNIPER AV Suite: A1 Lot: Location: APPLICANT MOFFAT DAVID Owner: Remarks: Total Time: en Description ' 'P~ ~ 't R..tgl: ilu.;tric -z.~ r-~ -·---_____ ,.. J_12 _F_~ 0 Act Comments Inspector: (VI, t., -~--- Requested By: SANFORD Entered By: KATHY cornments,Notlc1.?olas~iJt>. '$~~ ~~oll-e ~ji;:.-rlS~ OIJ.., 1", 2,4 (" I ~~f'~ el?-; Associated PCRs/~ Original PC# lnsE)ection Histo!Y Date Description Act lnsp Comments 02/25/2009 14 Frame/Steel/Bolting/Welding we MC 02/25/2009 89 Final Combo co MC NOTICE ATTACHED 11/13/2008 14 Frame/Steel/Bolting/Welding WC MC 11/13/2008 17 Interior Lath/Drywall AP MC 11/07/2008 92 Compliance Investigation PA MC GAS AND MECH. QUES. 11/04/2008 14 Frame/Steel/Bolting/Welding AP MC NEED LETTER FROM E.O.R. FOR NON-BEARING JOIST 11/04/2008 24 RoughfTopout AP MC 11/04/2008 34 Rough Electric AP MC 11/04/2008 44 Rough/Ducts/Dampers AP MC EXHAUST FAN DUCT ONLY I NSPECTRITEuSA PREMIER /NSPEC110N SERVICES www.inspectrite.com Client: Subject: Stan ford Sherman 1528 Monte Mar Road Vista, CA 92084 E: Sanford.Sherman@sbcglobal.net Repair of Notched Joists, 2"• Floor Framing 252 Juniper Avenue Carlsbad, CA File No.: R-080917A Repair Clarification InspectRite -Encinitas P.O. Box 231784 Encinitas, CA 92023 Telephone: 760/634-0505 Facsimile 760/634-1801 November 6, 20Q8 Where new 2x IO joist can not be installed as a full length joist with bearing on top plates, then the new joist may be installed without bearing on top plates provided that '/4" dia. lag screw spacing is reduced from 12" oc to 6" oc. Lag screws should have staggered spacing and full penetration. Respectfully submitted, INSPECTHITE -ENCINITAS ' . Robert Chappell, P:E. Lie. #C 60650 ., I NSPECTRITEuSA PREMIER INSPECTION SERVICES www.inspectrite.com Client: Subject: Stanford Sherman 1528 Monte Mar Road Vista, CA 92084 E: Sanford.Sherman@sbcglobal.net Notched Joists, 2"• Floor Framing 252 Juniper Avenue Carlsbad, CA File No.: R-080917A Dear Mr. Sherman: InspectRite -Encinitas P.O. Box 231784 Encinitas, CA 92023 Telephone: 760/634-0505 Facsimile 760/634-1801 October 29, 2008 Pursuant to your request, I investigated concerns with the structural framing at the above referenced property. Specifically, there was a concern that the floor joists above the kitchen area had been structurally compromised due to notching. A site visit was made to the property on I 0-27-08 to observe the condition. The ceiling of the kitchen was constructed of 2x IO joists at 16" oc, which supported the 2"'1 floor living area above. Three consecutive floor joists had been notched at the bottom edge along the middle of the span. The effective joist depth of each notched member ranged from 4 -5.5''. The joists were spanning approximately 8.5 feet. By analysis, the altered joists are not overstressed in bending, but are at approximately I 00% of thei, allowable bending stress based on code allowable design stresses. However, flexural member (beams and joists) shall not be notched along the bottom edge within the middle 1/3 span. Such notching is a code violation. Notching in this manner creates a stress riser at the point of the notch that concentrates stresses and may cause the flexural member to split even when stresses are within allowable design limits. Failure due to splitting could result particularly when considering impact and seismic loading. Consequently, the structural integrity of the floor framing has been compromised where the joists have been notched. Structural repair is needed to protect against possible splitting and failure. An appropriate repair is specified below. Repair I. Install one new 2x IO joist abutting each existing notched joist for the fol I length of the existing joist. INSPECTRITE -ENCINITAS Engineering & Inspections 2. Fasten each new joist to the existingjoist with¼" dia. lag screws, at 12" oc, staggered spacing, full penetration. 3. New joists shall be DFL No. 2 Grade or better. 4. Lag screws shall be predrilled with 50% -60% of the shank diameter. Cut washers shall be used so that screw heads do not bear on wood. 5. Construction and workmanship shall conform to the standards and practice of the industry and the requirements of the latest edition of the Uniform Building Code (UBC). Jfyou have any questions or would like further explanation, please do not hesitate to call InspectRite- Encinitas. Respectfully submitted, INSPECTRITE -ENCINITAS Robert Chappell, P.E. Lie. #C 60650 Pagel . ~-. • ~· f NSPECTRITEuSA PREMIER INSPECTION SERVICES www.inspectrite.com Client: Subject: Stanford Sherman 1528 Monte Mar Road Vista, CA 92084 E: Sanford.Shcrman(alsbcnlobal.net Notched Structural Wall Framing 252 Juniper Avenue Carlsbad, CA File No .. R-080917/, Dear Mr. Sherman: InspectRite -Encinitas P.O. Box 231784 Encinitas, CA 92023 Telephone: 760/634-0505 Facsimile 760/634-1801 September I <J. 2008 Pursuant to your request, I investigated concerns with the structural framing at the above relercnccd property. Specifically, there were concerns that the wood studs along the party wall in the kitchen had been structurally wmpromised by the installation of a plumbing waste line. I made a site visit to the property l)!l 9-i7-0S to nbs:;rve the cc,ndiLion. The residence ,vas a two-story condominium unit with the ki1cLcn un th~ Virsf level. 2x•~ wood ·,u1cls were observed at the east side party wall behind the kitchen cabinets. ll,c wood studs had been excessively notched, or completely severed at some studs, where a 3 inch diameter plumbing \\·astc line was installed. This occurred for a length of approximately 6 feet along the wall. The party wall was a load bearing wall supporting 2'"1 floor and roof loads. The structural integrity of the wall has been compromised where the studs were notched or scverc:d. Structural repair is needed to ensure stability of the wall framing. A repair recommendation has been specified in the attachment. If you have any questions or would like further explanation, please do not hesitate to call /11s1,cc-1/li1,,_ Encinitas. Respectfully submitted, /NSPECTHITE -ENCINITAS --' Subject: Specifications INSPECTRITE -ENCINITAS • PO Box 231784 • Encinitas, CA 92023 • Phone: 760/634-0505 • Fax: 760/634-/80/ ---------~-·------ Repair of Notched/Severed Structural Wall Framing 252 Juniper Avenue Carlsbad, CA File No,: R-0809l7A 1. Construction and workmanship shall conform to the standards and practice of the industry and the requirements of the latest edition of the Uniform Building Code ~C- 2. Use 2x4 DFLwood studs; Construction Grade, or No. 2 or better. 3. Lag screws shall be predrilled with 50% -60% of the shank diameter. Cut washers shall be used so that screw heads do not bear on wood. Repair Method I I. Install one new full length stud abutting each existing notched or severed stud. New studs shall have full bearing at existing top and bottom plates. 2. Toenail new studs to top and bottom plates per UBC Nailing Table. 3. Fasten each new stud to existing stud with a minimum of four (4) ¼" dia. la~ screws, full penetration. 2. Toenail new studs to the ottom plate pe 3. Fas:ten c.u.:h pair o nev, studs 10 existing stud with rninim11111 ei~ht (8) 1//' di:1. Ing screws. full penetration ( 4-1 /2"L). A-DO ~ L\UE. ~ -ro ~ (,,U (~\~ Walls to be fram 'cl @ 2X4 studs 16" o .. wl 4X4 headers f:/e 9'1 P · '3"" ~ T)PE "i-. "' ~ :-f()()-;rrnp panel ,· "' ' I 252 Juniper Ave. #A 1 Dining 20'-0" X 30"-0" 1,,_____ NJ" ---fl ~I 4()8 sq.ft 4"-0" X 4'-0 16 sq.It. ,..____,NI" I ~:--+---+---~ 1 added partition wall ' all other walls are existi Ga,age 13'-0" X 22'-0" 286sq.lt. 1---7 I I 13'~----Z--¥' ··~---211~·-- OCT 212008 City of CARLSBAD BUILDING DEPT. ' r .. 252 Juniper ave. #A 1 ,,__ ___ B'-4•-----l', / , a•-4• Cf) tX,S'TJNq r I ~f;, !)oOP- Fl/JV !Lt!' C'f:-/VT Exhaust fan WI light to be installed 1 toilet to be r&-attached to existing plumbing. /.6.7 jg. 1 sink to be r&-attached to existing plumbing. 1"'"- 1 new switch to be added for new light fixture.